SLAC Magnetic Measurements Date: 02-26-2012 Time: 10:58:35 Project: XTA Magnet Type: Quad Magnet Name: QE02X Serial Number: 002 Run Number: 1 Measurement Device: DC34 Operator: sda Comment: Integrated gradient and harmonics from -12 to +12 to -12 amps. Harmonics at +/- 12, 6, and 1 A. Trim disconnected. Magnetic Center Data Time Main +/- sigma X sigX Y sigY (A) (microns) (microns) --------- ------------+---------- --------+-------- --------+-------- 11:13:33 -12.0064 0.0001 659.15 0.19 26.54 0.24 11:36:53 -6.0052 0.0000 643.95 0.05 23.27 0.03 11:56:52 -0.9988 0.0000 565.85 0.12 -3.18 0.07 12:06:40 0.9981 0.0000 775.03 0.05 73.71 0.09 12:26:31 6.0047 0.0000 677.23 0.06 33.90 0.15 12:49:46 12.0058 0.0001 673.19 0.10 26.64 0.04