SLAC Magnetic Measurements Date: 07-30-2010 Time: 09:36:08 Project: X-Band_Injector Magnet Type: Solenoid Magnet Name: Compton_101_2nd Serial Number: 101 Run Number: 9 Measurement Device: Coil ZZ Operator: sda Comment: Transverse dipole fields vs z at magnet center (X = +7 mils, Y = +7 mils), magnet current = 200 A. z = 0 is upstream end plate. Standardization: 1 cycles from 5.0 A to 300.0 A to 5.0 A Test Currents (A): 200.0 09:37:16 Btcoil, device being used, type = SR850 09:38:23 Stage Zeroed 09:38:23 MoveZ Devices: Move Device = SXDRIVE, Read Device = SXDRIVE 09:38:28 Magnet Current, Imag = -0.002427 A Vtrans = -0.000024 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 09:38:28 Magnet Current, Imag = -0.002431 A Vtrans = -0.000024 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 09:38:29 Magnet Current, Imag = -0.002452 A Vtrans = -0.000025 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 09:38:30 Magnet Current, Imag = -0.002401 A Vtrans = -0.000024 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 09:38:30 Magnet Current Measurement: Imag = -0.0024 +- 0.0000 A 09:39:03 Initial Zero Current Measurement, Imag_zero = -0.0024 A 09:39:03 Magnet current ramping to 300.0000 A... 09:40:10 Magnet current ramping to 5.0000 A... 09:41:15 Magnet current ramping to 200.0000 A... 09:42:29 Move Stage, position = 0.150300 09:42:30 Stage Position Measurement, pos = 0.1497500 m 09:42:31 Magnet Current, Imag = 200.035518 A Vtrans = 2.000331 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002428 A 09:45:24 Coil Voltage Measurement meas_freq = 23.818000 Hz, meas_v_mag = 0.000032 V, meas_v_ph = 99.330000 deg freq = 23.818000 Hz, v_amp = 0.000045 V, v_ph = 9.330000 deg 09:45:24 Transverse Field Calculation freq = 23.818000 Hz, v_amp = 0.000045 V, v_ph = 9.330000 deg Coil Constant = 0.334200 (T/V0p) Transverse Field, Bt = 0.000015 T, THsp = -9.330000 deg 09:45:33 Move Stage, position = 0.125300 09:45:35 Stage Position Measurement, pos = 0.1254200 m 09:45:35 Magnet Current, Imag = 200.046358 A Vtrans = 2.000439 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002428 A 09:48:46 Coil Voltage Measurement meas_freq = 23.825600 Hz, meas_v_mag = 0.000020 V, meas_v_ph = -150.984000 deg freq = 23.825600 Hz, v_amp = 0.000028 V, v_ph = 119.016000 deg 09:48:46 Transverse Field Calculation freq = 23.825600 Hz, v_amp = 0.000028 V, v_ph = 119.016000 deg Coil Constant = 0.334200 (T/V0p) Transverse Field, Bt = 0.000009 T, THsp = -119.016000 deg 09:48:56 Move Stage, position = 0.100300 09:48:57 Stage Position Measurement, pos = 0.1003950 m 09:48:58 Magnet Current, Imag = 200.109978 A Vtrans = 2.001075 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002428 A 09:50:33 Coil Voltage Measurement meas_freq = 23.818000 Hz, meas_v_mag = 0.000048 V, meas_v_ph = 94.158000 deg freq = 23.818000 Hz, v_amp = 0.000068 V, v_ph = 4.158000 deg 09:50:33 Transverse Field Calculation freq = 23.818000 Hz, v_amp = 0.000068 V, v_ph = 4.158000 deg Coil Constant = 0.334200 (T/V0p) Transverse Field, Bt = 0.000023 T, THsp = -4.158000 deg 09:50:42 Move Stage, position = 0.075300 09:50:44 Stage Position Measurement, pos = 0.0754750 m 09:50:44 Magnet Current, Imag = 200.046878 A Vtrans = 2.000444 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002428 A 09:53:36 Coil Voltage Measurement meas_freq = 23.826600 Hz, meas_v_mag = 0.000029 V, meas_v_ph = 99.324000 deg freq = 23.826600 Hz, v_amp = 0.000041 V, v_ph = 9.324000 deg 09:53:36 Transverse Field Calculation freq = 23.826600 Hz, v_amp = 0.000041 V, v_ph = 9.324000 deg Coil Constant = 0.334200 (T/V0p) Transverse Field, Bt = 0.000014 T, THsp = -9.324000 deg 09:53:45 Move Stage, position = 0.050300 09:53:47 Stage Position Measurement, pos = 0.0503850 m 09:53:47 Magnet Current, Imag = 200.047798 A Vtrans = 2.000454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002428 A 09:56:40 Coil Voltage Measurement meas_freq = 23.829500 Hz, meas_v_mag = 0.000057 V, meas_v_ph = 152.424000 deg freq = 23.829500 Hz, v_amp = 0.000081 V, v_ph = 62.424000 deg 09:56:40 Transverse Field Calculation freq = 23.829500 Hz, v_amp = 0.000081 V, v_ph = 62.424000 deg Coil Constant = 0.334200 (T/V0p) Transverse Field, Bt = 0.000027 T, THsp = -62.424000 deg 09:56:49 Move Stage, position = 0.025300 09:56:51 Stage Position Measurement, pos = 0.0253900 m 09:56:52 Magnet Current, Imag = 200.059558 A Vtrans = 2.000571 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002428 A 09:59:44 Coil Voltage Measurement meas_freq = 23.825600 Hz, meas_v_mag = 0.000010 V, meas_v_ph = 126.054000 deg freq = 23.825600 Hz, v_amp = 0.000014 V, v_ph = 36.054000 deg 09:59:44 Transverse Field Calculation freq = 23.825600 Hz, v_amp = 0.000014 V, v_ph = 36.054000 deg Coil Constant = 0.334200 (T/V0p) Transverse Field, Bt = 0.000005 T, THsp = -36.054000 deg 09:59:54 Move Stage, position = 0.000300 09:59:55 Stage Position Measurement, pos = 0.0003250 m 09:59:56 Magnet Current, Imag = 200.106058 A Vtrans = 2.001036 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002428 A 10:01:30 Coil Voltage Measurement meas_freq = 23.824700 Hz, meas_v_mag = 0.000129 V, meas_v_ph = 41.304000 deg freq = 23.824700 Hz, v_amp = 0.000183 V, v_ph = -48.696000 deg 10:01:30 Transverse Field Calculation freq = 23.824700 Hz, v_amp = 0.000183 V, v_ph = -48.696000 deg Coil Constant = 0.334200 (T/V0p) Transverse Field, Bt = 0.000061 T, THsp = 48.696000 deg 10:01:39 Move Stage, position = -0.024700 10:01:41 Stage Position Measurement, pos = -0.0247100 m 10:01:42 Magnet Current, Imag = 200.033168 A Vtrans = 2.000307 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002428 A 10:03:14 Coil Voltage Measurement meas_freq = 23.830400 Hz, meas_v_mag = 0.000414 V, meas_v_ph = 30.666000 deg freq = 23.830400 Hz, v_amp = 0.000586 V, v_ph = -59.334000 deg 10:03:14 Transverse Field Calculation freq = 23.830400 Hz, v_amp = 0.000586 V, v_ph = -59.334000 deg Coil Constant = 0.334200 (T/V0p) Transverse Field, Bt = 0.000196 T, THsp = 59.334000 deg 10:03:23 Move Stage, position = -0.049700 10:03:25 Stage Position Measurement, pos = -0.0498050 m 10:03:25 Magnet Current, Imag = 200.043618 A Vtrans = 2.000412 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002428 A 10:04:58 Coil Voltage Measurement meas_freq = 23.827600 Hz, meas_v_mag = 0.000560 V, meas_v_ph = 61.950000 deg freq = 23.827600 Hz, v_amp = 0.000792 V, v_ph = -28.050000 deg 10:04:58 Transverse Field Calculation freq = 23.827600 Hz, v_amp = 0.000792 V, v_ph = -28.050000 deg Coil Constant = 0.334200 (T/V0p) Transverse Field, Bt = 0.000265 T, THsp = 28.050000 deg 10:05:07 Move Stage, position = -0.074700 10:05:09 Stage Position Measurement, pos = -0.0748650 m 10:05:09 Magnet Current, Imag = 200.017098 A Vtrans = 2.000147 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002428 A 10:08:00 Coil Voltage Measurement meas_freq = 23.833300 Hz, meas_v_mag = 0.000505 V, meas_v_ph = 60.690000 deg freq = 23.833300 Hz, v_amp = 0.000715 V, v_ph = -29.310000 deg 10:08:00 Transverse Field Calculation freq = 23.833300 Hz, v_amp = 0.000715 V, v_ph = -29.310000 deg Coil Constant = 0.334200 (T/V0p) Transverse Field, Bt = 0.000239 T, THsp = 29.310000 deg 10:08:09 Move Stage, position = -0.099700 10:08:11 Stage Position Measurement, pos = -0.0998850 m 10:08:12 Magnet Current, Imag = 200.093648 A Vtrans = 2.000912 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002428 A 10:11:03 Coil Voltage Measurement meas_freq = 23.834200 Hz, meas_v_mag = 0.000228 V, meas_v_ph = -4.350000 deg freq = 23.834200 Hz, v_amp = 0.000322 V, v_ph = -94.350000 deg 10:11:03 Transverse Field Calculation freq = 23.834200 Hz, v_amp = 0.000322 V, v_ph = -94.350000 deg Coil Constant = 0.334200 (T/V0p) Transverse Field, Bt = 0.000108 T, THsp = 94.350000 deg 10:11:13 Move Stage, position = -0.124700 10:11:14 Stage Position Measurement, pos = -0.1249150 m 10:11:15 Magnet Current, Imag = 200.072358 A Vtrans = 2.000699 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002428 A 10:12:48 Coil Voltage Measurement meas_freq = 23.832300 Hz, meas_v_mag = 0.000203 V, meas_v_ph = 92.706000 deg freq = 23.832300 Hz, v_amp = 0.000288 V, v_ph = 2.706000 deg 10:12:48 Transverse Field Calculation freq = 23.832300 Hz, v_amp = 0.000288 V, v_ph = 2.706000 deg Coil Constant = 0.334200 (T/V0p) Transverse Field, Bt = 0.000096 T, THsp = -2.706000 deg 10:12:58 Move Stage, position = -0.149700 10:12:59 Stage Position Measurement, pos = -0.1499300 m 10:13:00 Magnet Current, Imag = 200.036298 A Vtrans = 2.000339 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002428 A 10:14:32 Coil Voltage Measurement meas_freq = 23.834200 Hz, meas_v_mag = 0.000571 V, meas_v_ph = 92.988000 deg freq = 23.834200 Hz, v_amp = 0.000807 V, v_ph = 2.988000 deg 10:14:32 Transverse Field Calculation freq = 23.834200 Hz, v_amp = 0.000807 V, v_ph = 2.988000 deg Coil Constant = 0.334200 (T/V0p) Transverse Field, Bt = 0.000270 T, THsp = -2.988000 deg 10:14:42 Move Stage, position = -0.174700 10:14:43 Stage Position Measurement, pos = -0.1749550 m 10:14:44 Magnet Current, Imag = 200.029118 A Vtrans = 2.000267 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002428 A 10:16:16 Coil Voltage Measurement meas_freq = 23.828500 Hz, meas_v_mag = 0.000491 V, meas_v_ph = 101.184000 deg freq = 23.828500 Hz, v_amp = 0.000694 V, v_ph = 11.184000 deg 10:16:16 Transverse Field Calculation freq = 23.828500 Hz, v_amp = 0.000694 V, v_ph = 11.184000 deg Coil Constant = 0.334200 (T/V0p) Transverse Field, Bt = 0.000232 T, THsp = -11.184000 deg 10:16:26 Move Stage, position = -0.199700 10:16:27 Stage Position Measurement, pos = -0.2000050 m 10:16:28 Magnet Current, Imag = 200.030678 A Vtrans = 2.000282 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002428 A 10:19:17 Coil Voltage Measurement meas_freq = 23.822800 Hz, meas_v_mag = 0.000513 V, meas_v_ph = 130.158000 deg freq = 23.822800 Hz, v_amp = 0.000726 V, v_ph = 40.158000 deg 10:19:17 Transverse Field Calculation freq = 23.822800 Hz, v_amp = 0.000726 V, v_ph = 40.158000 deg Coil Constant = 0.334200 (T/V0p) Transverse Field, Bt = 0.000242 T, THsp = -40.158000 deg 10:19:26 Move Stage, position = -0.224700 10:19:28 Stage Position Measurement, pos = -0.2250400 m 10:19:29 Magnet Current, Imag = 200.039568 A Vtrans = 2.000371 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002428 A 10:21:01 Coil Voltage Measurement meas_freq = 23.824700 Hz, meas_v_mag = 0.000484 V, meas_v_ph = -176.964000 deg freq = 23.824700 Hz, v_amp = 0.000685 V, v_ph = 93.036000 deg 10:21:01 Transverse Field Calculation freq = 23.824700 Hz, v_amp = 0.000685 V, v_ph = 93.036000 deg Coil Constant = 0.334200 (T/V0p) Transverse Field, Bt = 0.000229 T, THsp = -93.036000 deg 10:21:10 Move Stage, position = -0.249700 10:21:12 Stage Position Measurement, pos = -0.2501450 m 10:21:12 Magnet Current, Imag = 200.048448 A Vtrans = 2.000460 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002428 A 10:22:46 Coil Voltage Measurement meas_freq = 23.821800 Hz, meas_v_mag = 0.000312 V, meas_v_ph = -91.014000 deg freq = 23.821800 Hz, v_amp = 0.000441 V, v_ph = 178.986000 deg 10:22:46 Transverse Field Calculation freq = 23.821800 Hz, v_amp = 0.000441 V, v_ph = 178.986000 deg Coil Constant = 0.334200 (T/V0p) Transverse Field, Bt = 0.000148 T, THsp = -178.986000 deg 10:22:55 Move Stage, position = -0.274700 10:22:57 Stage Position Measurement, pos = -0.2751350 m 10:22:57 Magnet Current, Imag = 200.034208 A Vtrans = 2.000318 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002428 A 10:24:30 Coil Voltage Measurement meas_freq = 23.822800 Hz, meas_v_mag = 0.000118 V, meas_v_ph = -48.942000 deg freq = 23.822800 Hz, v_amp = 0.000167 V, v_ph = -138.942000 deg 10:24:30 Transverse Field Calculation freq = 23.822800 Hz, v_amp = 0.000167 V, v_ph = -138.942000 deg Coil Constant = 0.334200 (T/V0p) Transverse Field, Bt = 0.000056 T, THsp = 138.942000 deg 10:24:40 Move Stage, position = -0.299700 10:24:41 Stage Position Measurement, pos = -0.3001700 m 10:24:42 Magnet Current, Imag = 200.035128 A Vtrans = 2.000327 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002428 A 10:27:36 Coil Voltage Measurement meas_freq = 23.827600 Hz, meas_v_mag = 0.000007 V, meas_v_ph = -32.934000 deg freq = 23.827600 Hz, v_amp = 0.000010 V, v_ph = -122.934000 deg 10:27:36 Transverse Field Calculation freq = 23.827600 Hz, v_amp = 0.000010 V, v_ph = -122.934000 deg Coil Constant = 0.334200 (T/V0p) Transverse Field, Bt = 0.000003 T, THsp = 122.934000 deg 10:27:45 Move Stage, position = -0.324700 10:27:47 Stage Position Measurement, pos = -0.3251600 m 10:27:47 Magnet Current, Imag = 200.026238 A Vtrans = 2.000238 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002428 A 10:30:39 Coil Voltage Measurement meas_freq = 23.819000 Hz, meas_v_mag = 0.000015 V, meas_v_ph = 174.804000 deg freq = 23.819000 Hz, v_amp = 0.000021 V, v_ph = 84.804000 deg 10:30:39 Transverse Field Calculation freq = 23.819000 Hz, v_amp = 0.000021 V, v_ph = 84.804000 deg Coil Constant = 0.334200 (T/V0p) Transverse Field, Bt = 0.000007 T, THsp = -84.804000 deg 10:30:48 Move Stage, position = -0.349700 10:30:50 Stage Position Measurement, pos = -0.3501800 m 10:30:50 Magnet Current, Imag = 200.044658 A Vtrans = 2.000422 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002428 A 10:32:42 Coil Voltage Measurement meas_freq = 23.816100 Hz, meas_v_mag = 0.000041 V, meas_v_ph = 117.852000 deg freq = 23.816100 Hz, v_amp = 0.000058 V, v_ph = 27.852000 deg 10:32:42 Transverse Field Calculation freq = 23.816100 Hz, v_amp = 0.000058 V, v_ph = 27.852000 deg Coil Constant = 0.334200 (T/V0p) Transverse Field, Bt = 0.000019 T, THsp = -27.852000 deg 10:32:51 Move Stage, position = -0.374700 10:32:53 Stage Position Measurement, pos = -0.3752000 m 10:32:54 Magnet Current, Imag = 200.042698 A Vtrans = 2.000403 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002428 A 10:34:29 Coil Voltage Measurement meas_freq = 23.823700 Hz, meas_v_mag = 0.000019 V, meas_v_ph = -169.146000 deg freq = 23.823700 Hz, v_amp = 0.000027 V, v_ph = 100.854000 deg 10:34:29 Transverse Field Calculation freq = 23.823700 Hz, v_amp = 0.000027 V, v_ph = 100.854000 deg Coil Constant = 0.334200 (T/V0p) Transverse Field, Bt = 0.000009 T, THsp = -100.854000 deg 10:34:38 Move Stage, position = -0.399700 10:34:40 Stage Position Measurement, pos = -0.4002900 m 10:34:40 Magnet Current, Imag = 200.035128 A Vtrans = 2.000327 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002428 A 10:37:33 Coil Voltage Measurement meas_freq = 23.819900 Hz, meas_v_mag = 0.000019 V, meas_v_ph = -158.466000 deg freq = 23.819900 Hz, v_amp = 0.000026 V, v_ph = 111.534000 deg 10:37:33 Transverse Field Calculation freq = 23.819900 Hz, v_amp = 0.000026 V, v_ph = 111.534000 deg Coil Constant = 0.334200 (T/V0p) Transverse Field, Bt = 0.000009 T, THsp = -111.534000 deg 10:38:32 Move Stage, position = 0.000000 10:38:33 Magnet current ramping to 0.0000 A...