SLAC Magnetic Measurements Date: 05-05-2003 Time: 15:42:56 Project: spear3 Magnet Type: Septum Magnet Name: B9V Serial Number: Run Number: 6 Measurement Device: 10 wire Operator: sa Comment: Leakage field in v notch at 273 amps. Wire is 30 mm away from narrow part of notch. Mirror plates are on Standardization: 3 cycles from 0.0 A to 330.0 A to 0.0 A Test Currents (A): 273.0 15:43:00 Initial Zero Current Measurement, Imag_zero = 0.0000 A 15:43:00 Magnet current ramping to 15.0000 A... 15:43:54 Magnet current ramping to 330.0000 A... 15:46:54 Magnet current ramping to 0.0000 A... 15:49:56 Magnet current ramping to 330.0000 A... 15:52:59 Magnet current ramping to 0.0000 A... 15:56:02 Magnet current ramping to 330.0000 A... 15:59:04 Magnet current ramping to 0.0000 A... 16:02:07 Magnet current ramping to 273.0000 A... 16:03:30 Magnet Current, Imag = 273.0693 A Vtrans = 2.730693 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:32 Magnet Current, Imag = 273.0547 A Vtrans = 2.730547 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:33 Magnet Current, Imag = 273.0558 A Vtrans = 2.730558 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:34 Magnet Current, Imag = 273.0227 A Vtrans = 2.730227 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:34 Magnet Current Measurement: Imag = 273.0506 +- 0.0171 A 16:03:34 Magnetic Field Measurement Measuring the magnet strength... 16:03:34 Integrated Voltage Measurement... 16:03:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000408083 Vs 16:03:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000421242 Vs 16:04:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000415166 Vs 16:04:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000420058 Vs 16:04:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000411159 Vs 16:04:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000420601 Vs 16:04:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000414015 Vs 16:04:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000419571 Vs 16:04:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000416237 +- 0.000001096 Vs 16:04:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000416237 +- 0.000001096 Vs BL = 0.00416237 +- 0.00001096 Tm 16:04:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00416 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00416 0.00001 0.00416 0.00000 16:04:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00416 0.00001 SL = 0.0041624 +- 0.0000110 Tm^2/m^n 16:04:52 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0041624 +- 0.0000110 Tm^2/m^n 16:04:53 Magnet Current, Imag = 273.0844 A Vtrans = 2.730844 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:04:55 Magnet Current, Imag = 273.0726 A Vtrans = 2.730726 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:04:56 Magnet Current, Imag = 273.0929 A Vtrans = 2.730929 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:04:57 Magnet Current, Imag = 273.0806 A Vtrans = 2.730806 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:04:57 Magnet Current Measurement: Imag = 273.0826 +- 0.0073 A 16:04:57 Magnet current ramping to 0.0000 A...