SLAC Magnetic Measurements Date: 07-17-2003 Time: 10:26:49 Project: spear3 Magnet Type: Septum Magnet Name: B9V Serial Number: Run Number: 14 Measurement Device: 10 wire Operator: sa Comment: Leakage field in v notch. Wire is 20 mm from bottom of pole. Final Mirror plate and mu shielding. Standardization: 3 cycles from 0.0 A to 330.0 A to 0.0 A Test Currents (A): 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 110.0 120.0 130.0 140.0 150.0 160.0 170.0 180.0 190.0 200.0 210.0 220.0 230.0 240.0 250.0 260.0 270.0 273.0 280.0 290.0 300.0 290.0 280.0 273.0 270.0 260.0 250.0 240.0 230.0 220.0 210.0 200.0 190.0 180.0 170.0 160.0 150.0 140.0 130.0 120.0 110.0 100.0 90.0 80.0 70.0 60.0 50.0 40.0 30.0 20.0 10.0 0.0 10:26:54 Initial Zero Current Measurement, Imag_zero = 0.0000 A 10:26:54 Magnet current ramping to 15.0000 A... 10:27:49 Magnet current ramping to 330.0000 A... 10:30:49 Magnet current ramping to 0.0000 A... 10:33:51 Magnet current ramping to 330.0000 A... 10:36:54 Magnet current ramping to 0.0000 A... 10:39:56 Magnet current ramping to 330.0000 A... 10:42:59 Magnet current ramping to 0.0000 A... 10:46:02 Magnet current ramping to 0.0000 A... 10:46:35 Magnet Current, Imag = 0.0052 A Vtrans = 0.000052 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:46:37 Magnet Current, Imag = 0.0052 A Vtrans = 0.000052 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:46:39 Magnet Current, Imag = 0.0052 A Vtrans = 0.000052 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:46:40 Magnet Current, Imag = 0.0052 A Vtrans = 0.000052 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:46:40 Magnet Current Measurement: Imag = 0.0052 +- 0.0000 A 10:46:40 Magnetic Field Measurement Measuring the magnet strength... 10:46:40 Integrated Voltage Measurement... 10:46:54 Voltage Offset Correction: v_off_ini = 0.000000929 V, v_off_fin = 0.000001532 V 10:46:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000022931 Vs 10:47:02 Voltage Offset Correction: v_off_ini = 0.000000997 V, v_off_fin = 0.000000811 V 10:47:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000022947 Vs 10:47:11 Voltage Offset Correction: v_off_ini = 0.000001148 V, v_off_fin = 0.000001674 V 10:47:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000021906 Vs 10:47:19 Voltage Offset Correction: v_off_ini = 0.000001094 V, v_off_fin = 0.000001476 V 10:47:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000021272 Vs 10:47:28 Voltage Offset Correction: v_off_ini = 0.000001068 V, v_off_fin = 0.000001312 V 10:47:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000022203 Vs 10:47:37 Voltage Offset Correction: v_off_ini = 0.000001212 V, v_off_fin = 0.000001799 V 10:47:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000022024 Vs 10:47:45 Voltage Offset Correction: v_off_ini = 0.000001333 V, v_off_fin = 0.000001590 V 10:47:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000021896 Vs 10:47:54 Voltage Offset Correction: v_off_ini = 0.000001222 V, v_off_fin = 0.000000578 V 10:47:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000021768 Vs 10:47:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000022118 +- 0.000000509 Vs 10:47:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000022118 +- 0.000000509 Vs BL = -0.00022118 +- 0.00000509 Tm 10:47:59 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00022 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00022 0.00001 -0.00022 0.00000 10:47:59 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00022 0.00001 SL = -0.0002212 +- 0.0000051 Tm^2/m^n 10:47:59 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0002212 +- 0.0000051 Tm^2/m^n 10:48:00 Magnet Current, Imag = 0.0050 A Vtrans = 0.000050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:48:02 Magnet Current, Imag = 0.0050 A Vtrans = 0.000050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:48:04 Magnet Current, Imag = 0.0050 A Vtrans = 0.000050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:48:05 Magnet Current, Imag = 0.0050 A Vtrans = 0.000050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:48:05 Magnet Current Measurement: Imag = 0.0050 +- 0.0000 A 10:48:05 Magnet current ramping to 10.0000 A... 10:48:41 Magnet Current, Imag = 10.0352 A Vtrans = 0.100352 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:48:43 Magnet Current, Imag = 10.0613 A Vtrans = 0.100613 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:48:44 Magnet Current, Imag = 10.0519 A Vtrans = 0.100519 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:48:46 Magnet Current, Imag = 10.0609 A Vtrans = 0.100609 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:48:46 Magnet Current Measurement: Imag = 10.0523 +- 0.0105 A 10:48:46 Magnetic Field Measurement Measuring the magnet strength... 10:48:46 Integrated Voltage Measurement... 10:48:59 Voltage Offset Correction: v_off_ini = 0.000001232 V, v_off_fin = 0.000001800 V 10:48:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000019937 Vs 10:49:08 Voltage Offset Correction: v_off_ini = 0.000001346 V, v_off_fin = 0.000000758 V 10:49:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000020966 Vs 10:49:16 Voltage Offset Correction: v_off_ini = 0.000000673 V, v_off_fin = 0.000001329 V 10:49:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000021349 Vs 10:49:25 Voltage Offset Correction: v_off_ini = 0.000000910 V, v_off_fin = 0.000001104 V 10:49:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000021530 Vs 10:49:33 Voltage Offset Correction: v_off_ini = 0.000001076 V, v_off_fin = 0.000001857 V 10:49:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000020643 Vs 10:49:42 Voltage Offset Correction: v_off_ini = 0.000002012 V, v_off_fin = 0.000002762 V 10:49:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000020999 Vs 10:49:51 Voltage Offset Correction: v_off_ini = 0.000001982 V, v_off_fin = 0.000001476 V 10:49:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000020641 Vs 10:49:59 Voltage Offset Correction: v_off_ini = 0.000001984 V, v_off_fin = 0.000001705 V 10:49:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000023227 Vs 10:49:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000021161 +- 0.000000569 Vs 10:49:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000021161 +- 0.000000569 Vs BL = -0.00021161 +- 0.00000569 Tm 10:50:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00021 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00021 0.00001 -0.00021 0.00000 10:50:04 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00021 0.00001 SL = -0.0002116 +- 0.0000057 Tm^2/m^n 10:50:04 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0002116 +- 0.0000057 Tm^2/m^n 10:50:06 Magnet Current, Imag = 10.0364 A Vtrans = 0.100364 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:08 Magnet Current, Imag = 10.0596 A Vtrans = 0.100596 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:09 Magnet Current, Imag = 10.0509 A Vtrans = 0.100509 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:11 Magnet Current, Imag = 10.0489 A Vtrans = 0.100489 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:11 Magnet Current Measurement: Imag = 10.0490 +- 0.0083 A 10:50:11 Magnet current ramping to 20.0000 A... 10:50:46 Magnet Current, Imag = 20.0181 A Vtrans = 0.200181 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:48 Magnet Current, Imag = 20.0163 A Vtrans = 0.200163 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:50 Magnet Current, Imag = 20.0153 A Vtrans = 0.200153 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:52 Magnet Current, Imag = 20.0226 A Vtrans = 0.200226 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:52 Magnet Current Measurement: Imag = 20.0181 +- 0.0028 A 10:50:52 Magnetic Field Measurement Measuring the magnet strength... 10:50:52 Integrated Voltage Measurement... 10:51:05 Voltage Offset Correction: v_off_ini = 0.000000481 V, v_off_fin = 0.000000826 V 10:51:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000016193 Vs 10:51:13 Voltage Offset Correction: v_off_ini = 0.000000957 V, v_off_fin = 0.000001765 V 10:51:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000015153 Vs 10:51:22 Voltage Offset Correction: v_off_ini = 0.000001137 V, v_off_fin = 0.000002105 V 10:51:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000016353 Vs 10:51:31 Voltage Offset Correction: v_off_ini = 0.000000894 V, v_off_fin = 0.000001102 V 10:51:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000015009 Vs 10:51:39 Voltage Offset Correction: v_off_ini = 0.000000821 V, v_off_fin = 0.000000932 V 10:51:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000015222 Vs 10:51:48 Voltage Offset Correction: v_off_ini = 0.000001233 V, v_off_fin = 0.000000883 V 10:51:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000013582 Vs 10:51:56 Voltage Offset Correction: v_off_ini = 0.000000800 V, v_off_fin = 0.000001032 V 10:51:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000015439 Vs 10:52:05 Voltage Offset Correction: v_off_ini = 0.000000771 V, v_off_fin = 0.000001066 V 10:52:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000014744 Vs 10:52:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000015212 +- 0.000000525 Vs 10:52:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000015212 +- 0.000000525 Vs BL = -0.00015212 +- 0.00000525 Tm 10:52:10 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00015 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00015 0.00001 -0.00015 0.00000 10:52:10 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00015 0.00001 SL = -0.0001521 +- 0.0000053 Tm^2/m^n 10:52:10 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0001521 +- 0.0000053 Tm^2/m^n 10:52:11 Magnet Current, Imag = 20.0263 A Vtrans = 0.200263 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:52:13 Magnet Current, Imag = 20.0203 A Vtrans = 0.200203 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:52:15 Magnet Current, Imag = 20.0133 A Vtrans = 0.200133 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:52:16 Magnet Current, Imag = 20.0219 A Vtrans = 0.200219 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:52:17 Magnet Current Measurement: Imag = 20.0204 +- 0.0047 A 10:52:17 Magnet current ramping to 30.0000 A... 10:52:52 Magnet Current, Imag = 30.0490 A Vtrans = 0.300490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:52:53 Magnet Current, Imag = 30.0603 A Vtrans = 0.300603 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:52:54 Magnet Current, Imag = 30.0695 A Vtrans = 0.300695 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:52:55 Magnet Current, Imag = 30.0607 A Vtrans = 0.300607 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:52:55 Magnet Current Measurement: Imag = 30.0599 +- 0.0073 A 10:52:55 Magnetic Field Measurement Measuring the magnet strength... 10:52:55 Integrated Voltage Measurement... 10:53:08 Voltage Offset Correction: v_off_ini = 0.000001627 V, v_off_fin = 0.000000671 V 10:53:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000013706 Vs 10:53:17 Voltage Offset Correction: v_off_ini = 0.000001066 V, v_off_fin = 0.000001125 V 10:53:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000012261 Vs 10:53:26 Voltage Offset Correction: v_off_ini = 0.000001628 V, v_off_fin = 0.000001519 V 10:53:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000012720 Vs 10:53:34 Voltage Offset Correction: v_off_ini = 0.000001196 V, v_off_fin = 0.000001257 V 10:53:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000013368 Vs 10:53:43 Voltage Offset Correction: v_off_ini = 0.000001085 V, v_off_fin = 0.000000657 V 10:53:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000011250 Vs 10:53:51 Voltage Offset Correction: v_off_ini = 0.000000857 V, v_off_fin = 0.000000254 V 10:53:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000012241 Vs 10:54:00 Voltage Offset Correction: v_off_ini = 0.000001082 V, v_off_fin = 0.000001047 V 10:54:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000013127 Vs 10:54:09 Voltage Offset Correction: v_off_ini = 0.000000298 V, v_off_fin = -0.000000478 V 10:54:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000012583 Vs 10:54:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000012657 +- 0.000000531 Vs 10:54:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000012657 +- 0.000000531 Vs BL = -0.00012657 +- 0.00000531 Tm 10:54:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00013 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00013 0.00001 -0.00013 0.00000 10:54:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00013 0.00001 SL = -0.0001266 +- 0.0000053 Tm^2/m^n 10:54:13 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0001266 +- 0.0000053 Tm^2/m^n 10:54:15 Magnet Current, Imag = 30.0747 A Vtrans = 0.300747 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:16 Magnet Current, Imag = 30.0677 A Vtrans = 0.300677 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:17 Magnet Current, Imag = 30.0690 A Vtrans = 0.300690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:18 Magnet Current, Imag = 30.0526 A Vtrans = 0.300526 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:18 Magnet Current Measurement: Imag = 30.0660 +- 0.0082 A 10:54:18 Magnet current ramping to 40.0000 A... 10:54:53 Magnet Current, Imag = 39.9401 A Vtrans = 0.399401 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:54 Magnet Current, Imag = 39.9241 A Vtrans = 0.399241 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:55 Magnet Current, Imag = 39.9462 A Vtrans = 0.399462 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:56 Magnet Current, Imag = 39.9531 A Vtrans = 0.399531 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:56 Magnet Current Measurement: Imag = 39.9409 +- 0.0107 A 10:54:56 Magnetic Field Measurement Measuring the magnet strength... 10:54:56 Integrated Voltage Measurement... 10:55:10 Voltage Offset Correction: v_off_ini = -0.000002180 V, v_off_fin = -0.000002349 V 10:55:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000010131 Vs 10:55:18 Voltage Offset Correction: v_off_ini = -0.000002996 V, v_off_fin = -0.000002647 V 10:55:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000010668 Vs 10:55:27 Voltage Offset Correction: v_off_ini = -0.000002406 V, v_off_fin = -0.000002480 V 10:55:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000010812 Vs 10:55:35 Voltage Offset Correction: v_off_ini = -0.000002020 V, v_off_fin = -0.000000698 V 10:55:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000011155 Vs 10:55:44 Voltage Offset Correction: v_off_ini = -0.000002181 V, v_off_fin = -0.000000891 V 10:55:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000009387 Vs 10:55:53 Voltage Offset Correction: v_off_ini = -0.000001009 V, v_off_fin = 0.000000108 V 10:55:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000009857 Vs 10:56:01 Voltage Offset Correction: v_off_ini = -0.000000629 V, v_off_fin = 0.000000170 V 10:56:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000009717 Vs 10:56:10 Voltage Offset Correction: v_off_ini = -0.000000655 V, v_off_fin = -0.000000577 V 10:56:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000010158 Vs 10:56:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000010236 +- 0.000000513 Vs 10:56:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000010236 +- 0.000000513 Vs BL = -0.00010236 +- 0.00000513 Tm 10:56:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00010 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00010 0.00001 -0.00010 0.00000 10:56:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00010 0.00001 SL = -0.0001024 +- 0.0000051 Tm^2/m^n 10:56:15 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0001024 +- 0.0000051 Tm^2/m^n 10:56:16 Magnet Current, Imag = 39.9434 A Vtrans = 0.399434 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:17 Magnet Current, Imag = 39.9480 A Vtrans = 0.399480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:18 Magnet Current, Imag = 39.9275 A Vtrans = 0.399275 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:19 Magnet Current, Imag = 39.9467 A Vtrans = 0.399467 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:19 Magnet Current Measurement: Imag = 39.9414 +- 0.0082 A 10:56:19 Magnet current ramping to 50.0000 A... 10:56:54 Magnet Current, Imag = 49.9830 A Vtrans = 0.499830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:55 Magnet Current, Imag = 50.0097 A Vtrans = 0.500097 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:56 Magnet Current, Imag = 50.0039 A Vtrans = 0.500039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:58 Magnet Current, Imag = 49.9990 A Vtrans = 0.499990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:58 Magnet Current Measurement: Imag = 49.9989 +- 0.0099 A 10:56:58 Magnetic Field Measurement Measuring the magnet strength... 10:56:58 Integrated Voltage Measurement... 10:57:11 Voltage Offset Correction: v_off_ini = -0.000000670 V, v_off_fin = -0.000000301 V 10:57:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000008861 Vs 10:57:19 Voltage Offset Correction: v_off_ini = -0.000000376 V, v_off_fin = -0.000000295 V 10:57:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000007289 Vs 10:57:28 Voltage Offset Correction: v_off_ini = -0.000000579 V, v_off_fin = -0.000000750 V 10:57:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000007928 Vs 10:57:36 Voltage Offset Correction: v_off_ini = -0.000000264 V, v_off_fin = -0.000000504 V 10:57:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000007069 Vs 10:57:45 Voltage Offset Correction: v_off_ini = -0.000000740 V, v_off_fin = -0.000000175 V 10:57:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000008352 Vs 10:57:54 Voltage Offset Correction: v_off_ini = -0.000000445 V, v_off_fin = -0.000000439 V 10:57:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000009090 Vs 10:58:02 Voltage Offset Correction: v_off_ini = -0.000000176 V, v_off_fin = 0.000000183 V 10:58:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000008831 Vs 10:58:11 Voltage Offset Correction: v_off_ini = -0.000000318 V, v_off_fin = 0.000000477 V 10:58:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000007969 Vs 10:58:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000008174 +- 0.000000452 Vs 10:58:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000008174 +- 0.000000452 Vs BL = -0.00008174 +- 0.00000452 Tm 10:58:16 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00008 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00008 0.00000 -0.00008 0.00000 10:58:16 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00008 0.00000 SL = -0.0000817 +- 0.0000045 Tm^2/m^n 10:58:16 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0000817 +- 0.0000045 Tm^2/m^n 10:58:17 Magnet Current, Imag = 50.0036 A Vtrans = 0.500036 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:18 Magnet Current, Imag = 50.0066 A Vtrans = 0.500066 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:19 Magnet Current, Imag = 49.9975 A Vtrans = 0.499975 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:21 Magnet Current, Imag = 50.0019 A Vtrans = 0.500019 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:21 Magnet Current Measurement: Imag = 50.0024 +- 0.0033 A 10:58:21 Magnet current ramping to 60.0000 A... 10:58:55 Magnet Current, Imag = 59.9708 A Vtrans = 0.599708 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:56 Magnet Current, Imag = 59.9559 A Vtrans = 0.599559 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:58 Magnet Current, Imag = 59.9862 A Vtrans = 0.599862 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:59 Magnet Current, Imag = 59.9678 A Vtrans = 0.599678 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:59 Magnet Current Measurement: Imag = 59.9702 +- 0.0108 A 10:58:59 Magnetic Field Measurement Measuring the magnet strength... 10:58:59 Integrated Voltage Measurement... 10:59:12 Voltage Offset Correction: v_off_ini = 0.000001219 V, v_off_fin = 0.000001663 V 10:59:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000007416 Vs 10:59:20 Voltage Offset Correction: v_off_ini = 0.000001036 V, v_off_fin = 0.000000602 V 10:59:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000008639 Vs 10:59:29 Voltage Offset Correction: v_off_ini = 0.000001247 V, v_off_fin = 0.000002065 V 10:59:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000006698 Vs 10:59:38 Voltage Offset Correction: v_off_ini = 0.000000930 V, v_off_fin = 0.000000947 V 10:59:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000007769 Vs 10:59:46 Voltage Offset Correction: v_off_ini = 0.000001177 V, v_off_fin = 0.000000842 V 10:59:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000007183 Vs 10:59:55 Voltage Offset Correction: v_off_ini = 0.000001281 V, v_off_fin = 0.000001590 V 10:59:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000006665 Vs 11:00:04 Voltage Offset Correction: v_off_ini = 0.000000541 V, v_off_fin = 0.000000504 V 11:00:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000006149 Vs 11:00:12 Voltage Offset Correction: v_off_ini = 0.000001066 V, v_off_fin = 0.000000788 V 11:00:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000005818 Vs 11:00:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000007042 +- 0.000000732 Vs 11:00:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000007042 +- 0.000000732 Vs BL = -0.00007042 +- 0.00000732 Tm 11:00:17 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00007 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00007 0.00001 -0.00007 0.00000 11:00:17 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00007 0.00001 SL = -0.0000704 +- 0.0000073 Tm^2/m^n 11:00:17 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0000704 +- 0.0000073 Tm^2/m^n 11:00:18 Magnet Current, Imag = 60.0003 A Vtrans = 0.600003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:19 Magnet Current, Imag = 59.9749 A Vtrans = 0.599749 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:21 Magnet Current, Imag = 59.9972 A Vtrans = 0.599972 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:22 Magnet Current, Imag = 59.9649 A Vtrans = 0.599649 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:22 Magnet Current Measurement: Imag = 59.9843 +- 0.0149 A 11:00:22 Magnet current ramping to 70.0000 A... 11:00:56 Magnet Current, Imag = 70.0174 A Vtrans = 0.700174 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:58 Magnet Current, Imag = 70.0312 A Vtrans = 0.700312 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:59 Magnet Current, Imag = 70.0187 A Vtrans = 0.700187 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:01:00 Magnet Current, Imag = 70.0292 A Vtrans = 0.700292 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:01:00 Magnet Current Measurement: Imag = 70.0241 +- 0.0061 A 11:01:00 Magnetic Field Measurement Measuring the magnet strength... 11:01:00 Integrated Voltage Measurement... 11:01:13 Voltage Offset Correction: v_off_ini = 0.000000556 V, v_off_fin = 0.000001244 V 11:01:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000006342 Vs 11:01:22 Voltage Offset Correction: v_off_ini = 0.000001095 V, v_off_fin = 0.000000574 V 11:01:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000005101 Vs 11:01:30 Voltage Offset Correction: v_off_ini = 0.000000756 V, v_off_fin = 0.000000741 V 11:01:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000006535 Vs 11:01:39 Voltage Offset Correction: v_off_ini = 0.000000572 V, v_off_fin = -0.000000539 V 11:01:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000005136 Vs 11:01:48 Voltage Offset Correction: v_off_ini = 0.000000563 V, v_off_fin = 0.000000573 V 11:01:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000005812 Vs 11:01:56 Voltage Offset Correction: v_off_ini = -0.000000050 V, v_off_fin = -0.000000440 V 11:01:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000004007 Vs 11:02:05 Voltage Offset Correction: v_off_ini = 0.000000429 V, v_off_fin = 0.000000765 V 11:02:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000007081 Vs 11:02:13 Voltage Offset Correction: v_off_ini = 0.000000506 V, v_off_fin = 0.000001107 V 11:02:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000004589 Vs 11:02:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000005575 +- 0.000000387 Vs 11:02:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000005575 +- 0.000000387 Vs BL = -0.00005575 +- 0.00000387 Tm 11:02:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00006 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00006 0.00000 -0.00006 0.00000 11:02:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00006 0.00000 SL = -0.0000558 +- 0.0000039 Tm^2/m^n 11:02:18 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0000558 +- 0.0000039 Tm^2/m^n 11:02:19 Magnet Current, Imag = 70.0306 A Vtrans = 0.700306 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:21 Magnet Current, Imag = 70.0271 A Vtrans = 0.700271 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:22 Magnet Current, Imag = 70.0253 A Vtrans = 0.700253 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:23 Magnet Current, Imag = 70.0269 A Vtrans = 0.700269 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:23 Magnet Current Measurement: Imag = 70.0275 +- 0.0019 A 11:02:23 Magnet current ramping to 80.0000 A... 11:02:58 Magnet Current, Imag = 79.8337 A Vtrans = 0.798337 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:59 Magnet Current, Imag = 79.8447 A Vtrans = 0.798447 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:03:00 Magnet Current, Imag = 79.8237 A Vtrans = 0.798237 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:03:01 Magnet Current, Imag = 79.8436 A Vtrans = 0.798436 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:03:01 Magnet Current Measurement: Imag = 79.8364 +- 0.0085 A 11:03:01 Magnetic Field Measurement Measuring the magnet strength... 11:03:01 Integrated Voltage Measurement... 11:03:14 Voltage Offset Correction: v_off_ini = 0.000000357 V, v_off_fin = 0.000000278 V 11:03:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000003744 Vs 11:03:23 Voltage Offset Correction: v_off_ini = 0.000000493 V, v_off_fin = 0.000000193 V 11:03:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000004718 Vs 11:03:31 Voltage Offset Correction: v_off_ini = 0.000000941 V, v_off_fin = 0.000002078 V 11:03:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000003521 Vs 11:03:40 Voltage Offset Correction: v_off_ini = 0.000000934 V, v_off_fin = 0.000000466 V 11:03:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000004280 Vs 11:03:49 Voltage Offset Correction: v_off_ini = 0.000000666 V, v_off_fin = 0.000000519 V 11:03:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000002182 Vs 11:03:57 Voltage Offset Correction: v_off_ini = 0.000000629 V, v_off_fin = 0.000000683 V 11:03:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000002187 Vs 11:04:06 Voltage Offset Correction: v_off_ini = -0.000000074 V, v_off_fin = -0.000001209 V 11:04:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000003054 Vs 11:04:15 Voltage Offset Correction: v_off_ini = -0.000000251 V, v_off_fin = -0.000001758 V 11:04:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000005367 Vs 11:04:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000003632 +- 0.000000846 Vs 11:04:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000003632 +- 0.000000846 Vs BL = -0.00003632 +- 0.00000846 Tm 11:04:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00004 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00004 0.00001 -0.00004 0.00000 11:04:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00004 0.00001 SL = -0.0000363 +- 0.0000085 Tm^2/m^n 11:04:19 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0000363 +- 0.0000085 Tm^2/m^n 11:04:21 Magnet Current, Imag = 79.8492 A Vtrans = 0.798492 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:22 Magnet Current, Imag = 79.8449 A Vtrans = 0.798449 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:23 Magnet Current, Imag = 79.8572 A Vtrans = 0.798572 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:24 Magnet Current, Imag = 79.8468 A Vtrans = 0.798468 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:24 Magnet Current Measurement: Imag = 79.8495 +- 0.0047 A 11:04:24 Magnet current ramping to 90.0000 A... 11:04:59 Magnet Current, Imag = 89.9053 A Vtrans = 0.899053 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:05:00 Magnet Current, Imag = 89.9124 A Vtrans = 0.899124 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:05:01 Magnet Current, Imag = 89.8954 A Vtrans = 0.898954 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:05:02 Magnet Current, Imag = 89.8973 A Vtrans = 0.898973 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:05:02 Magnet Current Measurement: Imag = 89.9026 +- 0.0068 A 11:05:02 Magnetic Field Measurement Measuring the magnet strength... 11:05:02 Integrated Voltage Measurement... 11:05:15 Voltage Offset Correction: v_off_ini = -0.000000446 V, v_off_fin = 0.000000010 V 11:05:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000001462 Vs 11:05:24 Voltage Offset Correction: v_off_ini = -0.000000361 V, v_off_fin = 0.000001756 V 11:05:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000003646 Vs 11:05:33 Voltage Offset Correction: v_off_ini = 0.000000230 V, v_off_fin = -0.000000054 V 11:05:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000004281 Vs 11:05:41 Voltage Offset Correction: v_off_ini = -0.000000280 V, v_off_fin = -0.000000669 V 11:05:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000004288 Vs 11:05:50 Voltage Offset Correction: v_off_ini = -0.000000163 V, v_off_fin = 0.000000355 V 11:05:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000002811 Vs 11:05:59 Voltage Offset Correction: v_off_ini = 0.000000349 V, v_off_fin = 0.000000342 V 11:05:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000002157 Vs 11:06:07 Voltage Offset Correction: v_off_ini = 0.000000597 V, v_off_fin = 0.000001316 V 11:06:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000002139 Vs 11:06:16 Voltage Offset Correction: v_off_ini = 0.000001768 V, v_off_fin = 0.000001983 V 11:06:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000003906 Vs 11:06:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000003086 +- 0.000000722 Vs 11:06:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000003086 +- 0.000000722 Vs BL = -0.00003086 +- 0.00000722 Tm 11:06:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00003 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00003 0.00001 -0.00003 0.00000 11:06:21 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00003 0.00001 SL = -0.0000309 +- 0.0000072 Tm^2/m^n 11:06:21 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0000309 +- 0.0000072 Tm^2/m^n 11:06:22 Magnet Current, Imag = 89.9054 A Vtrans = 0.899054 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:23 Magnet Current, Imag = 89.9047 A Vtrans = 0.899047 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:24 Magnet Current, Imag = 89.9051 A Vtrans = 0.899051 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:25 Magnet Current, Imag = 89.9149 A Vtrans = 0.899149 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:25 Magnet Current Measurement: Imag = 89.9075 +- 0.0043 A 11:06:25 Magnet current ramping to 100.0000 A... 11:07:00 Magnet Current, Imag = 99.8797 A Vtrans = 0.998797 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:07:01 Magnet Current, Imag = 99.8606 A Vtrans = 0.998606 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:07:02 Magnet Current, Imag = 99.8771 A Vtrans = 0.998771 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:07:03 Magnet Current, Imag = 99.8780 A Vtrans = 0.998780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:07:04 Magnet Current Measurement: Imag = 99.8738 +- 0.0077 A 11:07:04 Magnetic Field Measurement Measuring the magnet strength... 11:07:04 Integrated Voltage Measurement... 11:07:17 Voltage Offset Correction: v_off_ini = 0.000002447 V, v_off_fin = 0.000003180 V 11:07:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000003255 Vs 11:07:25 Voltage Offset Correction: v_off_ini = 0.000002814 V, v_off_fin = 0.000003432 V 11:07:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000001669 Vs 11:07:34 Voltage Offset Correction: v_off_ini = 0.000003703 V, v_off_fin = 0.000003341 V 11:07:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000001716 Vs 11:07:42 Voltage Offset Correction: v_off_ini = 0.000003913 V, v_off_fin = 0.000004499 V 11:07:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000002311 Vs 11:07:51 Voltage Offset Correction: v_off_ini = 0.000003941 V, v_off_fin = 0.000004125 V 11:07:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000001154 Vs 11:08:00 Voltage Offset Correction: v_off_ini = 0.000004045 V, v_off_fin = 0.000003617 V 11:08:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000003187 Vs 11:08:08 Voltage Offset Correction: v_off_ini = 0.000003519 V, v_off_fin = 0.000003844 V 11:08:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000003179 Vs 11:08:17 Voltage Offset Correction: v_off_ini = 0.000003516 V, v_off_fin = 0.000003571 V 11:08:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000000813 Vs 11:08:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000002160 +- 0.000000187 Vs 11:08:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000002160 +- 0.000000187 Vs BL = -0.00002160 +- 0.00000187 Tm 11:08:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00002 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00002 0.00000 -0.00002 0.00000 11:08:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00002 0.00000 SL = -0.0000216 +- 0.0000019 Tm^2/m^n 11:08:22 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0000216 +- 0.0000019 Tm^2/m^n 11:08:23 Magnet Current, Imag = 99.8680 A Vtrans = 0.998680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:08:24 Magnet Current, Imag = 99.8664 A Vtrans = 0.998664 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:08:25 Magnet Current, Imag = 99.8795 A Vtrans = 0.998795 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:08:26 Magnet Current, Imag = 99.8677 A Vtrans = 0.998677 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:08:27 Magnet Current Measurement: Imag = 99.8704 +- 0.0053 A 11:08:27 Magnet current ramping to 110.0000 A... 11:09:01 Magnet Current, Imag = 109.9808 A Vtrans = 1.099808 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:09:02 Magnet Current, Imag = 109.9262 A Vtrans = 1.099262 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:09:04 Magnet Current, Imag = 109.9301 A Vtrans = 1.099301 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:09:05 Magnet Current, Imag = 109.9207 A Vtrans = 1.099207 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:09:05 Magnet Current Measurement: Imag = 109.9394 +- 0.0241 A 11:09:05 Magnetic Field Measurement Measuring the magnet strength... 11:09:05 Integrated Voltage Measurement... 11:09:18 Voltage Offset Correction: v_off_ini = -0.000000167 V, v_off_fin = 0.000000487 V 11:09:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000004176 Vs 11:09:27 Voltage Offset Correction: v_off_ini = 0.000000512 V, v_off_fin = 0.000000891 V 11:09:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000001492 Vs 11:09:35 Voltage Offset Correction: v_off_ini = 0.000000686 V, v_off_fin = 0.000000569 V 11:09:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000056 Vs 11:09:44 Voltage Offset Correction: v_off_ini = 0.000001324 V, v_off_fin = 0.000001077 V 11:09:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000000924 Vs 11:09:52 Voltage Offset Correction: v_off_ini = 0.000001312 V, v_off_fin = 0.000002236 V 11:09:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000001622 Vs 11:10:01 Voltage Offset Correction: v_off_ini = 0.000001127 V, v_off_fin = 0.000000888 V 11:10:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000003765 Vs 11:10:10 Voltage Offset Correction: v_off_ini = 0.000001273 V, v_off_fin = 0.000000211 V 11:10:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000001083 Vs 11:10:18 Voltage Offset Correction: v_off_ini = -0.000000038 V, v_off_fin = -0.000000631 V 11:10:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000000675 Vs 11:10:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000000266 +- 0.000001504 Vs 11:10:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000000266 +- 0.000001504 Vs BL = -0.00000266 +- 0.00001504 Tm 11:10:23 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00000 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00000 0.00002 -0.00000 0.00000 11:10:23 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00000 0.00002 SL = -0.0000027 +- 0.0000150 Tm^2/m^n 11:10:23 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0000027 +- 0.0000150 Tm^2/m^n 11:10:24 Magnet Current, Imag = 109.9375 A Vtrans = 1.099375 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:10:25 Magnet Current, Imag = 109.9263 A Vtrans = 1.099263 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:10:27 Magnet Current, Imag = 109.9297 A Vtrans = 1.099297 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:10:28 Magnet Current, Imag = 109.9235 A Vtrans = 1.099235 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:10:28 Magnet Current Measurement: Imag = 109.9292 +- 0.0052 A 11:10:28 Magnet current ramping to 120.0000 A... 11:11:02 Magnet Current, Imag = 119.8254 A Vtrans = 1.198254 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:11:04 Magnet Current, Imag = 119.8195 A Vtrans = 1.198195 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:11:05 Magnet Current, Imag = 119.8169 A Vtrans = 1.198169 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:11:06 Magnet Current, Imag = 119.7937 A Vtrans = 1.197937 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:11:06 Magnet Current Measurement: Imag = 119.8139 +- 0.0120 A 11:11:06 Magnetic Field Measurement Measuring the magnet strength... 11:11:06 Integrated Voltage Measurement... 11:11:19 Voltage Offset Correction: v_off_ini = -0.000000855 V, v_off_fin = -0.000000332 V 11:11:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000732 Vs 11:11:28 Voltage Offset Correction: v_off_ini = -0.000000407 V, v_off_fin = -0.000000485 V 11:11:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000003184 Vs 11:11:36 Voltage Offset Correction: v_off_ini = -0.000000225 V, v_off_fin = 0.000000918 V 11:11:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000000504 Vs 11:11:45 Voltage Offset Correction: v_off_ini = -0.000000626 V, v_off_fin = 0.000000454 V 11:11:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000000265 Vs 11:11:54 Voltage Offset Correction: v_off_ini = 0.000000600 V, v_off_fin = 0.000000234 V 11:11:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000000264 Vs 11:12:02 Voltage Offset Correction: v_off_ini = -0.000000064 V, v_off_fin = -0.000000769 V 11:12:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000001957 Vs 11:12:11 Voltage Offset Correction: v_off_ini = 0.000000001 V, v_off_fin = 0.000001490 V 11:12:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000383 Vs 11:12:19 Voltage Offset Correction: v_off_ini = 0.000000338 V, v_off_fin = 0.000000328 V 11:12:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000002502 Vs 11:12:19 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000543 +- 0.000001223 Vs 11:12:19 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000000543 +- 0.000001223 Vs BL = 0.00000543 +- 0.00001223 Tm 11:12:24 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00001 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00001 0.00001 0.00001 0.00000 11:12:24 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00001 0.00001 SL = 0.0000054 +- 0.0000122 Tm^2/m^n 11:12:24 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0000054 +- 0.0000122 Tm^2/m^n 11:12:25 Magnet Current, Imag = 119.8250 A Vtrans = 1.198250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:12:27 Magnet Current, Imag = 119.7889 A Vtrans = 1.197889 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:12:28 Magnet Current, Imag = 119.8483 A Vtrans = 1.198483 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:12:29 Magnet Current, Imag = 119.8201 A Vtrans = 1.198201 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:12:29 Magnet Current Measurement: Imag = 119.8206 +- 0.0212 A 11:12:29 Magnet current ramping to 130.0000 A... 11:13:04 Magnet Current, Imag = 129.9108 A Vtrans = 1.299108 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:13:05 Magnet Current, Imag = 129.9158 A Vtrans = 1.299158 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:13:06 Magnet Current, Imag = 129.8940 A Vtrans = 1.298940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:13:07 Magnet Current, Imag = 129.9016 A Vtrans = 1.299016 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:13:07 Magnet Current Measurement: Imag = 129.9056 +- 0.0084 A 11:13:07 Magnetic Field Measurement Measuring the magnet strength... 11:13:07 Integrated Voltage Measurement... 11:13:20 Voltage Offset Correction: v_off_ini = 0.000002133 V, v_off_fin = 0.000001411 V 11:13:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000002410 Vs 11:13:29 Voltage Offset Correction: v_off_ini = 0.000002043 V, v_off_fin = 0.000002610 V 11:13:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000001736 Vs 11:13:38 Voltage Offset Correction: v_off_ini = 0.000001872 V, v_off_fin = 0.000002159 V 11:13:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000003287 Vs 11:13:46 Voltage Offset Correction: v_off_ini = 0.000002122 V, v_off_fin = 0.000002372 V 11:13:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000004034 Vs 11:13:55 Voltage Offset Correction: v_off_ini = 0.000002597 V, v_off_fin = 0.000002260 V 11:13:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000002612 Vs 11:14:03 Voltage Offset Correction: v_off_ini = 0.000001953 V, v_off_fin = 0.000001751 V 11:14:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000002929 Vs 11:14:12 Voltage Offset Correction: v_off_ini = 0.000001483 V, v_off_fin = 0.000001728 V 11:14:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000003501 Vs 11:14:21 Voltage Offset Correction: v_off_ini = 0.000001095 V, v_off_fin = 0.000001226 V 11:14:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000002307 Vs 11:14:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000002852 +- 0.000000563 Vs 11:14:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000002852 +- 0.000000563 Vs BL = 0.00002852 +- 0.00000563 Tm 11:14:25 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00003 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00003 0.00001 0.00003 0.00000 11:14:25 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00003 0.00001 SL = 0.0000285 +- 0.0000056 Tm^2/m^n 11:14:25 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0000285 +- 0.0000056 Tm^2/m^n 11:14:27 Magnet Current, Imag = 129.9075 A Vtrans = 1.299075 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:14:28 Magnet Current, Imag = 129.9014 A Vtrans = 1.299014 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:14:29 Magnet Current, Imag = 129.9047 A Vtrans = 1.299047 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:14:30 Magnet Current, Imag = 129.8901 A Vtrans = 1.298901 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:14:30 Magnet Current Measurement: Imag = 129.9009 +- 0.0066 A 11:14:30 Magnet current ramping to 140.0000 A... 11:15:05 Magnet Current, Imag = 139.8538 A Vtrans = 1.398538 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:15:06 Magnet Current, Imag = 139.8588 A Vtrans = 1.398588 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:15:07 Magnet Current, Imag = 139.8525 A Vtrans = 1.398525 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:15:08 Magnet Current, Imag = 139.8643 A Vtrans = 1.398643 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:15:08 Magnet Current Measurement: Imag = 139.8573 +- 0.0047 A 11:15:08 Magnetic Field Measurement Measuring the magnet strength... 11:15:08 Integrated Voltage Measurement... 11:15:22 Voltage Offset Correction: v_off_ini = 0.000000135 V, v_off_fin = 0.000000744 V 11:15:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000004633 Vs 11:15:30 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000154 V 11:15:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000003537 Vs 11:15:39 Voltage Offset Correction: v_off_ini = 0.000000581 V, v_off_fin = -0.000000064 V 11:15:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000003430 Vs 11:15:47 Voltage Offset Correction: v_off_ini = 0.000000793 V, v_off_fin = 0.000001583 V 11:15:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000006586 Vs 11:15:56 Voltage Offset Correction: v_off_ini = 0.000000946 V, v_off_fin = 0.000001446 V 11:15:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000004693 Vs 11:16:05 Voltage Offset Correction: v_off_ini = 0.000001030 V, v_off_fin = 0.000001148 V 11:16:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000008212 Vs 11:16:13 Voltage Offset Correction: v_off_ini = 0.000000392 V, v_off_fin = 0.000000101 V 11:16:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000006570 Vs 11:16:22 Voltage Offset Correction: v_off_ini = 0.000000031 V, v_off_fin = 0.000001370 V 11:16:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000004269 Vs 11:16:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000005241 +- 0.000000850 Vs 11:16:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000005241 +- 0.000000850 Vs BL = 0.00005241 +- 0.00000850 Tm 11:16:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00005 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00005 0.00001 0.00005 0.00000 11:16:27 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00005 0.00001 SL = 0.0000524 +- 0.0000085 Tm^2/m^n 11:16:27 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0000524 +- 0.0000085 Tm^2/m^n 11:16:28 Magnet Current, Imag = 139.8474 A Vtrans = 1.398474 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:16:29 Magnet Current, Imag = 139.8478 A Vtrans = 1.398478 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:16:30 Magnet Current, Imag = 139.8606 A Vtrans = 1.398606 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:16:31 Magnet Current, Imag = 139.8511 A Vtrans = 1.398511 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:16:32 Magnet Current Measurement: Imag = 139.8517 +- 0.0053 A 11:16:32 Magnet current ramping to 150.0000 A... 11:17:06 Magnet Current, Imag = 149.9426 A Vtrans = 1.499426 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:17:07 Magnet Current, Imag = 149.9222 A Vtrans = 1.499222 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:17:09 Magnet Current, Imag = 149.9243 A Vtrans = 1.499243 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:17:10 Magnet Current, Imag = 149.9197 A Vtrans = 1.499197 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:17:10 Magnet Current Measurement: Imag = 149.9272 +- 0.0090 A 11:17:10 Magnetic Field Measurement Measuring the magnet strength... 11:17:10 Integrated Voltage Measurement... 11:17:23 Voltage Offset Correction: v_off_ini = 0.000000583 V, v_off_fin = 0.000001159 V 11:17:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000006390 Vs 11:17:32 Voltage Offset Correction: v_off_ini = 0.000000340 V, v_off_fin = -0.000000237 V 11:17:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000010718 Vs 11:17:40 Voltage Offset Correction: v_off_ini = 0.000000097 V, v_off_fin = 0.000001116 V 11:17:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000009473 Vs 11:17:49 Voltage Offset Correction: v_off_ini = 0.000000378 V, v_off_fin = 0.000000927 V 11:17:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000007862 Vs 11:17:57 Voltage Offset Correction: v_off_ini = 0.000000354 V, v_off_fin = 0.000000040 V 11:17:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000008896 Vs 11:18:06 Voltage Offset Correction: v_off_ini = 0.000000663 V, v_off_fin = 0.000001890 V 11:18:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000007075 Vs 11:18:15 Voltage Offset Correction: v_off_ini = 0.000000542 V, v_off_fin = 0.000000749 V 11:18:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000007046 Vs 11:18:23 Voltage Offset Correction: v_off_ini = 0.000000445 V, v_off_fin = 0.000000334 V 11:18:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000007346 Vs 11:18:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000008101 +- 0.000000583 Vs 11:18:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000008101 +- 0.000000583 Vs BL = 0.00008101 +- 0.00000583 Tm 11:18:28 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00008 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00008 0.00001 0.00008 0.00000 11:18:28 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00008 0.00001 SL = 0.0000810 +- 0.0000058 Tm^2/m^n 11:18:28 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0000810 +- 0.0000058 Tm^2/m^n 11:18:29 Magnet Current, Imag = 149.9268 A Vtrans = 1.499268 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:18:31 Magnet Current, Imag = 149.9198 A Vtrans = 1.499198 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:18:32 Magnet Current, Imag = 149.9303 A Vtrans = 1.499303 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:18:33 Magnet Current, Imag = 149.9337 A Vtrans = 1.499337 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:18:33 Magnet Current Measurement: Imag = 149.9276 +- 0.0051 A 11:18:33 Magnet current ramping to 160.0000 A... 11:19:08 Magnet Current, Imag = 159.8004 A Vtrans = 1.598004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:19:09 Magnet Current, Imag = 159.8011 A Vtrans = 1.598011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:19:10 Magnet Current, Imag = 159.8050 A Vtrans = 1.598050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:19:11 Magnet Current, Imag = 159.7936 A Vtrans = 1.597936 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:19:11 Magnet Current Measurement: Imag = 159.8000 +- 0.0041 A 11:19:11 Magnetic Field Measurement Measuring the magnet strength... 11:19:11 Integrated Voltage Measurement... 11:19:24 Voltage Offset Correction: v_off_ini = 0.000000460 V, v_off_fin = 0.000001291 V 11:19:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000010989 Vs 11:19:33 Voltage Offset Correction: v_off_ini = 0.000000737 V, v_off_fin = 0.000001352 V 11:19:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000009536 Vs 11:19:42 Voltage Offset Correction: v_off_ini = 0.000000971 V, v_off_fin = 0.000001380 V 11:19:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000010911 Vs 11:19:50 Voltage Offset Correction: v_off_ini = 0.000001222 V, v_off_fin = -0.000000184 V 11:19:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000010789 Vs 11:19:59 Voltage Offset Correction: v_off_ini = 0.000001034 V, v_off_fin = 0.000001524 V 11:19:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000010893 Vs 11:20:07 Voltage Offset Correction: v_off_ini = 0.000001134 V, v_off_fin = 0.000002034 V 11:20:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000011017 Vs 11:20:16 Voltage Offset Correction: v_off_ini = 0.000001077 V, v_off_fin = 0.000000601 V 11:20:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000010598 Vs 11:20:25 Voltage Offset Correction: v_off_ini = 0.000000976 V, v_off_fin = 0.000001584 V 11:20:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000010176 Vs 11:20:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000010614 +- 0.000000295 Vs 11:20:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000010614 +- 0.000000295 Vs BL = 0.00010614 +- 0.00000295 Tm 11:20:30 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00011 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00011 0.00000 0.00011 0.00000 11:20:30 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00011 0.00000 SL = 0.0001061 +- 0.0000029 Tm^2/m^n 11:20:30 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0001061 +- 0.0000029 Tm^2/m^n 11:20:31 Magnet Current, Imag = 159.7999 A Vtrans = 1.597999 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:20:32 Magnet Current, Imag = 159.7862 A Vtrans = 1.597862 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:20:33 Magnet Current, Imag = 159.7972 A Vtrans = 1.597972 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:20:34 Magnet Current, Imag = 159.8247 A Vtrans = 1.598247 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:20:34 Magnet Current Measurement: Imag = 159.8020 +- 0.0141 A 11:20:35 Magnet current ramping to 170.0000 A... 11:21:09 Magnet Current, Imag = 169.8538 A Vtrans = 1.698538 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:21:10 Magnet Current, Imag = 169.8808 A Vtrans = 1.698808 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:21:11 Magnet Current, Imag = 169.8555 A Vtrans = 1.698555 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:21:13 Magnet Current, Imag = 169.8630 A Vtrans = 1.698630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:21:13 Magnet Current Measurement: Imag = 169.8633 +- 0.0107 A 11:21:13 Magnetic Field Measurement Measuring the magnet strength... 11:21:13 Integrated Voltage Measurement... 11:21:26 Voltage Offset Correction: v_off_ini = 0.000002141 V, v_off_fin = 0.000001749 V 11:21:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000013747 Vs 11:21:34 Voltage Offset Correction: v_off_ini = 0.000002218 V, v_off_fin = 0.000001585 V 11:21:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000013042 Vs 11:21:43 Voltage Offset Correction: v_off_ini = 0.000001352 V, v_off_fin = 0.000002224 V 11:21:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000011708 Vs 11:21:52 Voltage Offset Correction: v_off_ini = 0.000001612 V, v_off_fin = 0.000001876 V 11:21:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000012387 Vs 11:22:00 Voltage Offset Correction: v_off_ini = 0.000001465 V, v_off_fin = 0.000001585 V 11:22:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000012744 Vs 11:22:09 Voltage Offset Correction: v_off_ini = 0.000001022 V, v_off_fin = 0.000000347 V 11:22:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000011913 Vs 11:22:18 Voltage Offset Correction: v_off_ini = 0.000000864 V, v_off_fin = 0.000000828 V 11:22:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000013314 Vs 11:22:26 Voltage Offset Correction: v_off_ini = 0.000001253 V, v_off_fin = 0.000001405 V 11:22:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000012923 Vs 11:22:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000012722 +- 0.000000552 Vs 11:22:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000012722 +- 0.000000552 Vs BL = 0.00012722 +- 0.00000552 Tm 11:22:31 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00013 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00013 0.00001 0.00013 0.00000 11:22:31 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00013 0.00001 SL = 0.0001272 +- 0.0000055 Tm^2/m^n 11:22:31 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0001272 +- 0.0000055 Tm^2/m^n 11:22:32 Magnet Current, Imag = 169.8464 A Vtrans = 1.698464 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:22:33 Magnet Current, Imag = 169.8542 A Vtrans = 1.698542 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:22:35 Magnet Current, Imag = 169.8590 A Vtrans = 1.698590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:22:36 Magnet Current, Imag = 169.8515 A Vtrans = 1.698515 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:22:36 Magnet Current Measurement: Imag = 169.8528 +- 0.0046 A 11:22:36 Magnet current ramping to 180.0000 A... 11:23:10 Magnet Current, Imag = 179.8145 A Vtrans = 1.798145 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:23:12 Magnet Current, Imag = 179.8144 A Vtrans = 1.798144 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:23:13 Magnet Current, Imag = 179.8308 A Vtrans = 1.798308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:23:14 Magnet Current, Imag = 179.8137 A Vtrans = 1.798137 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:23:14 Magnet Current Measurement: Imag = 179.8184 +- 0.0072 A 11:23:14 Magnetic Field Measurement Measuring the magnet strength... 11:23:14 Integrated Voltage Measurement... 11:23:27 Voltage Offset Correction: v_off_ini = -0.000000395 V, v_off_fin = -0.000001239 V 11:23:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000014895 Vs 11:23:36 Voltage Offset Correction: v_off_ini = -0.000000356 V, v_off_fin = -0.000000738 V 11:23:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000014436 Vs 11:23:45 Voltage Offset Correction: v_off_ini = -0.000000542 V, v_off_fin = 0.000000345 V 11:23:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000016092 Vs 11:23:53 Voltage Offset Correction: v_off_ini = -0.000000516 V, v_off_fin = -0.000000472 V 11:23:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000014970 Vs 11:24:02 Voltage Offset Correction: v_off_ini = -0.000000553 V, v_off_fin = 0.000000140 V 11:24:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000016459 Vs 11:24:10 Voltage Offset Correction: v_off_ini = -0.000000758 V, v_off_fin = -0.000001548 V 11:24:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000013652 Vs 11:24:19 Voltage Offset Correction: v_off_ini = -0.000000646 V, v_off_fin = -0.000001098 V 11:24:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000014399 Vs 11:24:28 Voltage Offset Correction: v_off_ini = -0.000000921 V, v_off_fin = -0.000000284 V 11:24:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000014459 Vs 11:24:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000014920 +- 0.000000418 Vs 11:24:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000014920 +- 0.000000418 Vs BL = 0.00014920 +- 0.00000418 Tm 11:24:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00015 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00015 0.00000 0.00015 0.00000 11:24:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00015 0.00000 SL = 0.0001492 +- 0.0000042 Tm^2/m^n 11:24:32 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0001492 +- 0.0000042 Tm^2/m^n 11:24:34 Magnet Current, Imag = 179.8190 A Vtrans = 1.798190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:24:35 Magnet Current, Imag = 179.8191 A Vtrans = 1.798191 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:24:36 Magnet Current, Imag = 179.8258 A Vtrans = 1.798258 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:24:37 Magnet Current, Imag = 179.7935 A Vtrans = 1.797935 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:24:37 Magnet Current Measurement: Imag = 179.8143 +- 0.0123 A 11:24:37 Magnet current ramping to 190.0000 A... 11:25:12 Magnet Current, Imag = 190.1520 A Vtrans = 1.901520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:25:13 Magnet Current, Imag = 190.1580 A Vtrans = 1.901580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:25:14 Magnet Current, Imag = 190.1676 A Vtrans = 1.901676 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:25:15 Magnet Current, Imag = 190.1647 A Vtrans = 1.901647 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:25:16 Magnet Current Measurement: Imag = 190.1606 +- 0.0061 A 11:25:16 Magnetic Field Measurement Measuring the magnet strength... 11:25:16 Integrated Voltage Measurement... 11:25:29 Voltage Offset Correction: v_off_ini = -0.000001503 V, v_off_fin = 0.000000110 V 11:25:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000018773 Vs 11:25:37 Voltage Offset Correction: v_off_ini = -0.000001498 V, v_off_fin = -0.000001376 V 11:25:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000019296 Vs 11:25:46 Voltage Offset Correction: v_off_ini = -0.000001126 V, v_off_fin = -0.000000970 V 11:25:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000017577 Vs 11:25:55 Voltage Offset Correction: v_off_ini = -0.000001528 V, v_off_fin = -0.000000703 V 11:25:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000018380 Vs 11:26:03 Voltage Offset Correction: v_off_ini = -0.000001521 V, v_off_fin = -0.000002645 V 11:26:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000019119 Vs 11:26:12 Voltage Offset Correction: v_off_ini = -0.000001326 V, v_off_fin = -0.000001098 V 11:26:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000019679 Vs 11:26:20 Voltage Offset Correction: v_off_ini = -0.000000962 V, v_off_fin = -0.000001631 V 11:26:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000018593 Vs 11:26:29 Voltage Offset Correction: v_off_ini = -0.000000817 V, v_off_fin = -0.000000663 V 11:26:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000018491 Vs 11:26:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000018738 +- 0.000000534 Vs 11:26:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000018738 +- 0.000000534 Vs BL = 0.00018738 +- 0.00000534 Tm 11:26:34 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00019 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00019 0.00001 0.00019 0.00000 11:26:34 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00019 0.00001 SL = 0.0001874 +- 0.0000053 Tm^2/m^n 11:26:34 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0001874 +- 0.0000053 Tm^2/m^n 11:26:35 Magnet Current, Imag = 190.1717 A Vtrans = 1.901717 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:26:36 Magnet Current, Imag = 190.1808 A Vtrans = 1.901808 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:26:37 Magnet Current, Imag = 190.1675 A Vtrans = 1.901675 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:26:39 Magnet Current, Imag = 190.1478 A Vtrans = 1.901478 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:26:39 Magnet Current Measurement: Imag = 190.1669 +- 0.0121 A 11:26:39 Magnet current ramping to 200.0000 A... 11:27:13 Magnet Current, Imag = 200.0387 A Vtrans = 2.000387 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:27:15 Magnet Current, Imag = 200.0148 A Vtrans = 2.000148 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:27:16 Magnet Current, Imag = 200.0514 A Vtrans = 2.000514 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:27:17 Magnet Current, Imag = 200.0361 A Vtrans = 2.000361 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:27:17 Magnet Current Measurement: Imag = 200.0352 +- 0.0131 A 11:27:17 Magnetic Field Measurement Measuring the magnet strength... 11:27:17 Integrated Voltage Measurement... 11:27:30 Voltage Offset Correction: v_off_ini = 0.000000968 V, v_off_fin = -0.000000169 V 11:27:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000020082 Vs 11:27:39 Voltage Offset Correction: v_off_ini = 0.000001114 V, v_off_fin = 0.000000759 V 11:27:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000023010 Vs 11:27:47 Voltage Offset Correction: v_off_ini = 0.000000701 V, v_off_fin = 0.000001010 V 11:27:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000022417 Vs 11:27:56 Voltage Offset Correction: v_off_ini = 0.000000775 V, v_off_fin = 0.000001098 V 11:27:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000021397 Vs 11:28:05 Voltage Offset Correction: v_off_ini = 0.000001019 V, v_off_fin = -0.000000646 V 11:28:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000024979 Vs 11:28:13 Voltage Offset Correction: v_off_ini = 0.000000971 V, v_off_fin = -0.000000128 V 11:28:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000020548 Vs 11:28:22 Voltage Offset Correction: v_off_ini = 0.000000391 V, v_off_fin = -0.000000995 V 11:28:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000021228 Vs 11:28:30 Voltage Offset Correction: v_off_ini = -0.000000598 V, v_off_fin = -0.000001337 V 11:28:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000024831 Vs 11:28:31 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000022312 +- 0.000000606 Vs 11:28:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000022312 +- 0.000000606 Vs BL = 0.00022312 +- 0.00000606 Tm 11:28:35 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00022 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00022 0.00001 0.00022 0.00000 11:28:35 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00022 0.00001 SL = 0.0002231 +- 0.0000061 Tm^2/m^n 11:28:35 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0002231 +- 0.0000061 Tm^2/m^n 11:28:37 Magnet Current, Imag = 200.0520 A Vtrans = 2.000520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:28:38 Magnet Current, Imag = 200.0411 A Vtrans = 2.000411 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:28:39 Magnet Current, Imag = 200.0268 A Vtrans = 2.000268 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:28:40 Magnet Current, Imag = 200.0611 A Vtrans = 2.000611 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:28:40 Magnet Current Measurement: Imag = 200.0452 +- 0.0128 A 11:28:40 Magnet current ramping to 210.0000 A... 11:29:15 Magnet Current, Imag = 210.0788 A Vtrans = 2.100788 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:29:16 Magnet Current, Imag = 210.1135 A Vtrans = 2.101135 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:29:17 Magnet Current, Imag = 210.1408 A Vtrans = 2.101408 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:29:18 Magnet Current, Imag = 210.1050 A Vtrans = 2.101050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:29:18 Magnet Current Measurement: Imag = 210.1095 +- 0.0221 A 11:29:18 Magnetic Field Measurement Measuring the magnet strength... 11:29:18 Integrated Voltage Measurement... 11:29:32 Voltage Offset Correction: v_off_ini = 0.000000760 V, v_off_fin = 0.000001080 V 11:29:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000025848 Vs 11:29:40 Voltage Offset Correction: v_off_ini = 0.000000684 V, v_off_fin = 0.000001767 V 11:29:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000025783 Vs 11:29:49 Voltage Offset Correction: v_off_ini = 0.000000491 V, v_off_fin = 0.000000309 V 11:29:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000025078 Vs 11:29:57 Voltage Offset Correction: v_off_ini = 0.000000438 V, v_off_fin = 0.000001942 V 11:29:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000025264 Vs 11:30:06 Voltage Offset Correction: v_off_ini = 0.000000491 V, v_off_fin = 0.000000825 V 11:30:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000023278 Vs 11:30:15 Voltage Offset Correction: v_off_ini = -0.000000193 V, v_off_fin = 0.000001051 V 11:30:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000024598 Vs 11:30:23 Voltage Offset Correction: v_off_ini = 0.000000126 V, v_off_fin = -0.000000340 V 11:30:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000024600 Vs 11:30:32 Voltage Offset Correction: v_off_ini = -0.000000602 V, v_off_fin = -0.000000700 V 11:30:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000026501 Vs 11:30:32 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000025119 +- 0.000000719 Vs 11:30:32 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000025119 +- 0.000000719 Vs BL = 0.00025119 +- 0.00000719 Tm 11:30:37 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00025 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00025 0.00001 0.00025 0.00000 11:30:37 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00025 0.00001 SL = 0.0002512 +- 0.0000072 Tm^2/m^n 11:30:37 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0002512 +- 0.0000072 Tm^2/m^n 11:30:38 Magnet Current, Imag = 210.1276 A Vtrans = 2.101276 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:30:39 Magnet Current, Imag = 210.1114 A Vtrans = 2.101114 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:30:40 Magnet Current, Imag = 210.1099 A Vtrans = 2.101099 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:30:42 Magnet Current, Imag = 210.1165 A Vtrans = 2.101165 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:30:42 Magnet Current Measurement: Imag = 210.1163 +- 0.0069 A 11:30:42 Magnet current ramping to 220.0000 A... 11:31:16 Magnet Current, Imag = 220.0638 A Vtrans = 2.200638 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:31:17 Magnet Current, Imag = 220.0722 A Vtrans = 2.200722 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:31:19 Magnet Current, Imag = 220.0687 A Vtrans = 2.200687 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:31:20 Magnet Current, Imag = 220.0702 A Vtrans = 2.200702 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:31:20 Magnet Current Measurement: Imag = 220.0687 +- 0.0031 A 11:31:20 Magnetic Field Measurement Measuring the magnet strength... 11:31:20 Integrated Voltage Measurement... 11:31:33 Voltage Offset Correction: v_off_ini = -0.000000142 V, v_off_fin = 0.000000335 V 11:31:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000028004 Vs 11:31:42 Voltage Offset Correction: v_off_ini = -0.000000135 V, v_off_fin = -0.000000251 V 11:31:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000030939 Vs 11:31:50 Voltage Offset Correction: v_off_ini = -0.000000059 V, v_off_fin = -0.000000189 V 11:31:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000030093 Vs 11:31:59 Voltage Offset Correction: v_off_ini = 0.000000110 V, v_off_fin = 0.000000542 V 11:31:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000029873 Vs 11:32:07 Voltage Offset Correction: v_off_ini = 0.000000195 V, v_off_fin = 0.000000827 V 11:32:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000029985 Vs 11:32:16 Voltage Offset Correction: v_off_ini = 0.000000241 V, v_off_fin = 0.000000100 V 11:32:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000030545 Vs 11:32:25 Voltage Offset Correction: v_off_ini = 0.000000682 V, v_off_fin = -0.000000001 V 11:32:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000027975 Vs 11:32:33 Voltage Offset Correction: v_off_ini = 0.000000584 V, v_off_fin = 0.000001651 V 11:32:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000029732 Vs 11:32:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000029643 +- 0.000000537 Vs 11:32:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000029643 +- 0.000000537 Vs BL = 0.00029643 +- 0.00000537 Tm 11:32:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00030 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00030 0.00001 0.00030 0.00000 11:32:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00030 0.00001 SL = 0.0002964 +- 0.0000054 Tm^2/m^n 11:32:38 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0002964 +- 0.0000054 Tm^2/m^n 11:32:39 Magnet Current, Imag = 220.0854 A Vtrans = 2.200854 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:32:41 Magnet Current, Imag = 220.0747 A Vtrans = 2.200747 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:32:42 Magnet Current, Imag = 220.1978 A Vtrans = 2.201978 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:32:43 Magnet Current, Imag = 220.0525 A Vtrans = 2.200525 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:32:43 Magnet Current Measurement: Imag = 220.1026 +- 0.0562 A 11:32:43 Magnet current ramping to 230.0000 A... 11:33:18 Magnet Current, Imag = 230.1789 A Vtrans = 2.301789 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:33:19 Magnet Current, Imag = 230.1622 A Vtrans = 2.301622 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:33:20 Magnet Current, Imag = 230.1634 A Vtrans = 2.301634 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:33:21 Magnet Current, Imag = 230.1658 A Vtrans = 2.301658 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:33:21 Magnet Current Measurement: Imag = 230.1676 +- 0.0067 A 11:33:21 Magnetic Field Measurement Measuring the magnet strength... 11:33:21 Integrated Voltage Measurement... 11:33:34 Voltage Offset Correction: v_off_ini = 0.000001035 V, v_off_fin = 0.000000648 V 11:33:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000032294 Vs 11:33:43 Voltage Offset Correction: v_off_ini = 0.000000544 V, v_off_fin = 0.000002224 V 11:33:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000033597 Vs 11:33:52 Voltage Offset Correction: v_off_ini = 0.000000469 V, v_off_fin = 0.000000515 V 11:33:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000033357 Vs 11:34:00 Voltage Offset Correction: v_off_ini = 0.000000314 V, v_off_fin = 0.000001137 V 11:34:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000033425 Vs 11:34:09 Voltage Offset Correction: v_off_ini = 0.000000515 V, v_off_fin = 0.000001558 V 11:34:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000030937 Vs 11:34:17 Voltage Offset Correction: v_off_ini = 0.000000367 V, v_off_fin = 0.000001162 V 11:34:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000033808 Vs 11:34:26 Voltage Offset Correction: v_off_ini = 0.000000670 V, v_off_fin = 0.000000161 V 11:34:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000031671 Vs 11:34:35 Voltage Offset Correction: v_off_ini = 0.000000844 V, v_off_fin = -0.000000357 V 11:34:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000032807 Vs 11:34:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000032737 +- 0.000000462 Vs 11:34:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000032737 +- 0.000000462 Vs BL = 0.00032737 +- 0.00000462 Tm 11:34:39 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00033 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00033 0.00000 0.00033 0.00000 11:34:39 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00033 0.00000 SL = 0.0003274 +- 0.0000046 Tm^2/m^n 11:34:39 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0003274 +- 0.0000046 Tm^2/m^n 11:34:41 Magnet Current, Imag = 230.1712 A Vtrans = 2.301712 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:34:42 Magnet Current, Imag = 230.1690 A Vtrans = 2.301690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:34:43 Magnet Current, Imag = 230.1735 A Vtrans = 2.301735 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:34:44 Magnet Current, Imag = 230.1651 A Vtrans = 2.301651 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:34:44 Magnet Current Measurement: Imag = 230.1697 +- 0.0031 A 11:34:44 Magnet current ramping to 240.0000 A... 11:35:19 Magnet Current, Imag = 239.9470 A Vtrans = 2.399470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:35:20 Magnet Current, Imag = 239.9550 A Vtrans = 2.399550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:35:21 Magnet Current, Imag = 239.9515 A Vtrans = 2.399515 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:35:23 Magnet Current, Imag = 239.9491 A Vtrans = 2.399491 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:35:23 Magnet Current Measurement: Imag = 239.9506 +- 0.0030 A 11:35:23 Magnetic Field Measurement Measuring the magnet strength... 11:35:23 Integrated Voltage Measurement... 11:35:36 Voltage Offset Correction: v_off_ini = 0.000001490 V, v_off_fin = 0.000000929 V 11:35:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000038060 Vs 11:35:44 Voltage Offset Correction: v_off_ini = 0.000001174 V, v_off_fin = 0.000001682 V 11:35:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000037519 Vs 11:35:53 Voltage Offset Correction: v_off_ini = 0.000000665 V, v_off_fin = 0.000000320 V 11:35:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000036403 Vs 11:36:02 Voltage Offset Correction: v_off_ini = -0.000000137 V, v_off_fin = -0.000000344 V 11:36:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000036840 Vs 11:36:10 Voltage Offset Correction: v_off_ini = -0.000000214 V, v_off_fin = -0.000000754 V 11:36:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000038725 Vs 11:36:19 Voltage Offset Correction: v_off_ini = -0.000000478 V, v_off_fin = -0.000000045 V 11:36:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000037463 Vs 11:36:27 Voltage Offset Correction: v_off_ini = -0.000000450 V, v_off_fin = 0.000000016 V 11:36:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000038594 Vs 11:36:36 Voltage Offset Correction: v_off_ini = -0.000000545 V, v_off_fin = -0.000000866 V 11:36:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000035599 Vs 11:36:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000037400 +- 0.000000577 Vs 11:36:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000037400 +- 0.000000577 Vs BL = 0.00037400 +- 0.00000577 Tm 11:36:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00037 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00037 0.00001 0.00037 0.00000 11:36:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00037 0.00001 SL = 0.0003740 +- 0.0000058 Tm^2/m^n 11:36:41 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0003740 +- 0.0000058 Tm^2/m^n 11:36:42 Magnet Current, Imag = 239.9564 A Vtrans = 2.399564 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:36:43 Magnet Current, Imag = 239.9603 A Vtrans = 2.399603 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:36:44 Magnet Current, Imag = 239.9577 A Vtrans = 2.399577 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:36:46 Magnet Current, Imag = 239.9622 A Vtrans = 2.399622 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:36:46 Magnet Current Measurement: Imag = 239.9591 +- 0.0023 A 11:36:46 Magnet current ramping to 250.0000 A... 11:37:20 Magnet Current, Imag = 250.0219 A Vtrans = 2.500219 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:37:22 Magnet Current, Imag = 250.0198 A Vtrans = 2.500198 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:37:23 Magnet Current, Imag = 250.0155 A Vtrans = 2.500155 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:37:24 Magnet Current, Imag = 250.0179 A Vtrans = 2.500179 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:37:24 Magnet Current Measurement: Imag = 250.0188 +- 0.0024 A 11:37:24 Magnetic Field Measurement Measuring the magnet strength... 11:37:24 Integrated Voltage Measurement... 11:37:37 Voltage Offset Correction: v_off_ini = 0.000000772 V, v_off_fin = -0.000000155 V 11:37:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000042011 Vs 11:37:46 Voltage Offset Correction: v_off_ini = 0.000000757 V, v_off_fin = -0.000000142 V 11:37:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000041415 Vs 11:37:54 Voltage Offset Correction: v_off_ini = 0.000000661 V, v_off_fin = 0.000001280 V 11:37:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000042433 Vs 11:38:03 Voltage Offset Correction: v_off_ini = 0.000000665 V, v_off_fin = 0.000001434 V 11:38:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000043753 Vs 11:38:12 Voltage Offset Correction: v_off_ini = 0.000000280 V, v_off_fin = -0.000000285 V 11:38:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000042243 Vs 11:38:20 Voltage Offset Correction: v_off_ini = -0.000000235 V, v_off_fin = -0.000000919 V 11:38:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000040457 Vs 11:38:29 Voltage Offset Correction: v_off_ini = -0.000000674 V, v_off_fin = -0.000000485 V 11:38:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000041325 Vs 11:38:37 Voltage Offset Correction: v_off_ini = -0.000000479 V, v_off_fin = -0.000000441 V 11:38:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000041636 Vs 11:38:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000041909 +- 0.000000696 Vs 11:38:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000041909 +- 0.000000696 Vs BL = 0.00041909 +- 0.00000696 Tm 11:38:42 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00042 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00042 0.00001 0.00042 0.00000 11:38:42 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00042 0.00001 SL = 0.0004191 +- 0.0000070 Tm^2/m^n 11:38:42 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0004191 +- 0.0000070 Tm^2/m^n 11:38:43 Magnet Current, Imag = 250.0176 A Vtrans = 2.500176 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:38:45 Magnet Current, Imag = 250.0252 A Vtrans = 2.500252 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:38:46 Magnet Current, Imag = 250.0208 A Vtrans = 2.500208 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:38:47 Magnet Current, Imag = 250.0296 A Vtrans = 2.500296 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:38:47 Magnet Current Measurement: Imag = 250.0233 +- 0.0045 A 11:38:47 Magnet current ramping to 260.0000 A... 11:39:22 Magnet Current, Imag = 259.9745 A Vtrans = 2.599745 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:39:23 Magnet Current, Imag = 259.9628 A Vtrans = 2.599628 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:39:24 Magnet Current, Imag = 259.9729 A Vtrans = 2.599729 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:39:25 Magnet Current, Imag = 259.9769 A Vtrans = 2.599769 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:39:25 Magnet Current Measurement: Imag = 259.9718 +- 0.0054 A 11:39:25 Magnetic Field Measurement Measuring the magnet strength... 11:39:25 Integrated Voltage Measurement... 11:39:38 Voltage Offset Correction: v_off_ini = 0.000000251 V, v_off_fin = 0.000000175 V 11:39:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000050934 Vs 11:39:47 Voltage Offset Correction: v_off_ini = 0.000000225 V, v_off_fin = 0.000000527 V 11:39:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000048939 Vs 11:39:56 Voltage Offset Correction: v_off_ini = -0.000000382 V, v_off_fin = 0.000000523 V 11:39:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000049650 Vs 11:40:04 Voltage Offset Correction: v_off_ini = -0.000000305 V, v_off_fin = -0.000001293 V 11:40:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000049829 Vs 11:40:13 Voltage Offset Correction: v_off_ini = -0.000000439 V, v_off_fin = -0.000000523 V 11:40:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000049122 Vs 11:40:22 Voltage Offset Correction: v_off_ini = -0.000000671 V, v_off_fin = -0.000000409 V 11:40:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000050459 Vs 11:40:30 Voltage Offset Correction: v_off_ini = -0.000000282 V, v_off_fin = -0.000000941 V 11:40:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000050286 Vs 11:40:39 Voltage Offset Correction: v_off_ini = -0.000000856 V, v_off_fin = -0.000000590 V 11:40:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000050710 Vs 11:40:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000049991 +- 0.000000302 Vs 11:40:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000049991 +- 0.000000302 Vs BL = 0.00049991 +- 0.00000302 Tm 11:40:44 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00050 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00050 0.00000 0.00050 0.00000 11:40:44 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00050 0.00000 SL = 0.0004999 +- 0.0000030 Tm^2/m^n 11:40:44 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0004999 +- 0.0000030 Tm^2/m^n 11:40:45 Magnet Current, Imag = 259.9755 A Vtrans = 2.599755 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:40:46 Magnet Current, Imag = 259.9802 A Vtrans = 2.599802 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:40:47 Magnet Current, Imag = 259.9717 A Vtrans = 2.599717 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:40:48 Magnet Current, Imag = 259.9826 A Vtrans = 2.599826 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:40:48 Magnet Current Measurement: Imag = 259.9775 +- 0.0042 A 11:40:49 Magnet current ramping to 270.0000 A... 11:41:23 Magnet Current, Imag = 270.0531 A Vtrans = 2.700531 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:41:24 Magnet Current, Imag = 270.0442 A Vtrans = 2.700442 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:41:25 Magnet Current, Imag = 270.0414 A Vtrans = 2.700414 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:41:27 Magnet Current, Imag = 270.0456 A Vtrans = 2.700456 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:41:27 Magnet Current Measurement: Imag = 270.0461 +- 0.0043 A 11:41:27 Magnetic Field Measurement Measuring the magnet strength... 11:41:27 Integrated Voltage Measurement... 11:41:40 Voltage Offset Correction: v_off_ini = -0.000000435 V, v_off_fin = -0.000000698 V 11:41:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000062064 Vs 11:41:48 Voltage Offset Correction: v_off_ini = -0.000000387 V, v_off_fin = 0.000000007 V 11:41:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000059625 Vs 11:41:57 Voltage Offset Correction: v_off_ini = -0.000000144 V, v_off_fin = -0.000000664 V 11:41:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000060470 Vs 11:42:06 Voltage Offset Correction: v_off_ini = -0.000000253 V, v_off_fin = -0.000000887 V 11:42:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000063232 Vs 11:42:14 Voltage Offset Correction: v_off_ini = -0.000000150 V, v_off_fin = -0.000000465 V 11:42:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000062598 Vs 11:42:23 Voltage Offset Correction: v_off_ini = 0.000000219 V, v_off_fin = 0.000000430 V 11:42:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000061433 Vs 11:42:31 Voltage Offset Correction: v_off_ini = 0.000000360 V, v_off_fin = 0.000001789 V 11:42:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000058947 Vs 11:42:40 Voltage Offset Correction: v_off_ini = 0.000000228 V, v_off_fin = 0.000000517 V 11:42:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000062406 Vs 11:42:40 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000061347 +- 0.000000592 Vs 11:42:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000061347 +- 0.000000592 Vs BL = 0.00061347 +- 0.00000592 Tm 11:42:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00061 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00061 0.00001 0.00061 0.00000 11:42:45 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00061 0.00001 SL = 0.0006135 +- 0.0000059 Tm^2/m^n 11:42:45 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0006135 +- 0.0000059 Tm^2/m^n 11:42:46 Magnet Current, Imag = 270.0539 A Vtrans = 2.700539 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:42:47 Magnet Current, Imag = 270.0492 A Vtrans = 2.700492 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:42:48 Magnet Current, Imag = 270.0534 A Vtrans = 2.700534 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:42:50 Magnet Current, Imag = 270.0588 A Vtrans = 2.700588 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:42:50 Magnet Current Measurement: Imag = 270.0538 +- 0.0034 A 11:42:50 Magnet current ramping to 273.0000 A... 11:43:23 Magnet Current, Imag = 273.1622 A Vtrans = 2.731622 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:43:24 Magnet Current, Imag = 273.1693 A Vtrans = 2.731693 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:43:26 Magnet Current, Imag = 273.1638 A Vtrans = 2.731638 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:43:27 Magnet Current, Imag = 273.1659 A Vtrans = 2.731659 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:43:27 Magnet Current Measurement: Imag = 273.1653 +- 0.0027 A 11:43:27 Magnetic Field Measurement Measuring the magnet strength... 11:43:27 Integrated Voltage Measurement... 11:43:40 Voltage Offset Correction: v_off_ini = 0.000000078 V, v_off_fin = 0.000000300 V 11:43:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000066198 Vs 11:43:49 Voltage Offset Correction: v_off_ini = 0.000000080 V, v_off_fin = -0.000001359 V 11:43:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000067754 Vs 11:43:57 Voltage Offset Correction: v_off_ini = -0.000000686 V, v_off_fin = -0.000000611 V 11:43:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000064969 Vs 11:44:06 Voltage Offset Correction: v_off_ini = -0.000000834 V, v_off_fin = 0.000000369 V 11:44:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000066682 Vs 11:44:14 Voltage Offset Correction: v_off_ini = -0.000001052 V, v_off_fin = -0.000001405 V 11:44:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000067203 Vs 11:44:23 Voltage Offset Correction: v_off_ini = -0.000000820 V, v_off_fin = 0.000000968 V 11:44:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000068049 Vs 11:44:32 Voltage Offset Correction: v_off_ini = -0.000000347 V, v_off_fin = -0.000000587 V 11:44:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000066961 Vs 11:44:40 Voltage Offset Correction: v_off_ini = -0.000000336 V, v_off_fin = 0.000001870 V 11:44:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000067198 Vs 11:44:40 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000066877 +- 0.000000655 Vs 11:44:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000066877 +- 0.000000655 Vs BL = 0.00066877 +- 0.00000655 Tm 11:44:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00067 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00067 0.00001 0.00067 0.00000 11:44:45 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00067 0.00001 SL = 0.0006688 +- 0.0000066 Tm^2/m^n 11:44:45 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0006688 +- 0.0000066 Tm^2/m^n 11:44:46 Magnet Current, Imag = 273.1647 A Vtrans = 2.731647 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:44:47 Magnet Current, Imag = 273.1684 A Vtrans = 2.731684 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:44:49 Magnet Current, Imag = 273.1698 A Vtrans = 2.731698 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:44:50 Magnet Current, Imag = 273.1685 A Vtrans = 2.731685 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:44:50 Magnet Current Measurement: Imag = 273.1678 +- 0.0019 A 11:44:50 Magnet current ramping to 280.0000 A... 11:45:24 Magnet Current, Imag = 279.9490 A Vtrans = 2.799490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:45:25 Magnet Current, Imag = 279.9516 A Vtrans = 2.799516 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:45:26 Magnet Current, Imag = 279.9444 A Vtrans = 2.799444 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:45:27 Magnet Current, Imag = 279.9516 A Vtrans = 2.799516 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:45:27 Magnet Current Measurement: Imag = 279.9491 +- 0.0029 A 11:45:27 Magnetic Field Measurement Measuring the magnet strength... 11:45:27 Integrated Voltage Measurement... 11:45:40 Voltage Offset Correction: v_off_ini = -0.000000507 V, v_off_fin = -0.000000465 V 11:45:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000081523 Vs 11:45:49 Voltage Offset Correction: v_off_ini = -0.000000542 V, v_off_fin = -0.000000632 V 11:45:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000084365 Vs 11:45:58 Voltage Offset Correction: v_off_ini = -0.000000597 V, v_off_fin = -0.000000021 V 11:45:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000083597 Vs 11:46:06 Voltage Offset Correction: v_off_ini = -0.000000612 V, v_off_fin = -0.000000865 V 11:46:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000079495 Vs 11:46:15 Voltage Offset Correction: v_off_ini = -0.000000844 V, v_off_fin = -0.000000579 V 11:46:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000082572 Vs 11:46:23 Voltage Offset Correction: v_off_ini = -0.000000918 V, v_off_fin = -0.000000797 V 11:46:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000080460 Vs 11:46:32 Voltage Offset Correction: v_off_ini = -0.000000990 V, v_off_fin = -0.000001123 V 11:46:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000081657 Vs 11:46:41 Voltage Offset Correction: v_off_ini = -0.000001329 V, v_off_fin = -0.000001869 V 11:46:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000079341 Vs 11:46:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000081626 +- 0.000000870 Vs 11:46:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000081626 +- 0.000000870 Vs BL = 0.00081626 +- 0.00000870 Tm 11:46:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00082 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00082 0.00001 0.00082 0.00000 11:46:45 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00082 0.00001 SL = 0.0008163 +- 0.0000087 Tm^2/m^n 11:46:46 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0008163 +- 0.0000087 Tm^2/m^n 11:46:47 Magnet Current, Imag = 279.9478 A Vtrans = 2.799478 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:46:48 Magnet Current, Imag = 279.9456 A Vtrans = 2.799456 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:46:49 Magnet Current, Imag = 279.9536 A Vtrans = 2.799536 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:46:50 Magnet Current, Imag = 279.9579 A Vtrans = 2.799579 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:46:50 Magnet Current Measurement: Imag = 279.9512 +- 0.0048 A 11:46:50 Magnet current ramping to 290.0000 A... 11:47:25 Magnet Current, Imag = 290.0316 A Vtrans = 2.900316 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:47:26 Magnet Current, Imag = 290.0278 A Vtrans = 2.900278 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:47:27 Magnet Current, Imag = 290.0312 A Vtrans = 2.900312 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:47:29 Magnet Current, Imag = 290.0245 A Vtrans = 2.900245 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:47:29 Magnet Current Measurement: Imag = 290.0288 +- 0.0029 A 11:47:29 Magnetic Field Measurement Measuring the magnet strength... 11:47:29 Integrated Voltage Measurement... 11:47:42 Voltage Offset Correction: v_off_ini = -0.000000952 V, v_off_fin = -0.000000547 V 11:47:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000122916 Vs 11:47:50 Voltage Offset Correction: v_off_ini = -0.000000242 V, v_off_fin = -0.000000592 V 11:47:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000123882 Vs 11:47:59 Voltage Offset Correction: v_off_ini = -0.000000400 V, v_off_fin = 0.000000114 V 11:47:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000122612 Vs 11:48:08 Voltage Offset Correction: v_off_ini = -0.000000338 V, v_off_fin = 0.000000778 V 11:48:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000122351 Vs 11:48:16 Voltage Offset Correction: v_off_ini = 0.000000402 V, v_off_fin = 0.000000525 V 11:48:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000122589 Vs 11:48:25 Voltage Offset Correction: v_off_ini = 0.000000358 V, v_off_fin = -0.000000649 V 11:48:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000121259 Vs 11:48:33 Voltage Offset Correction: v_off_ini = 0.000000440 V, v_off_fin = 0.000000318 V 11:48:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000124462 Vs 11:48:42 Voltage Offset Correction: v_off_ini = 0.000001026 V, v_off_fin = 0.000001518 V 11:48:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000120605 Vs 11:48:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000122584 +- 0.000000528 Vs 11:48:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000122584 +- 0.000000528 Vs BL = 0.00122584 +- 0.00000528 Tm 11:48:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00123 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00123 0.00001 0.00123 0.00000 11:48:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00123 0.00001 SL = 0.0012258 +- 0.0000053 Tm^2/m^n 11:48:47 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0012258 +- 0.0000053 Tm^2/m^n 11:48:48 Magnet Current, Imag = 290.0295 A Vtrans = 2.900295 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:48:49 Magnet Current, Imag = 290.0543 A Vtrans = 2.900543 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:48:50 Magnet Current, Imag = 290.0272 A Vtrans = 2.900272 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:48:52 Magnet Current, Imag = 290.0386 A Vtrans = 2.900386 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:48:52 Magnet Current Measurement: Imag = 290.0374 +- 0.0106 A 11:48:52 Magnet current ramping to 300.0000 A... 11:49:26 Magnet Current, Imag = 299.9751 A Vtrans = 2.999751 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:49:28 Magnet Current, Imag = 299.9788 A Vtrans = 2.999788 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:49:29 Magnet Current, Imag = 299.9770 A Vtrans = 2.999770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:49:30 Magnet Current, Imag = 299.9734 A Vtrans = 2.999734 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:49:30 Magnet Current Measurement: Imag = 299.9761 +- 0.0020 A 11:49:30 Magnetic Field Measurement Measuring the magnet strength... 11:49:30 Integrated Voltage Measurement... 11:49:43 Voltage Offset Correction: v_off_ini = 0.000000368 V, v_off_fin = -0.000000077 V 11:49:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000189688 Vs 11:49:52 Voltage Offset Correction: v_off_ini = 0.000000495 V, v_off_fin = 0.000000901 V 11:49:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000185782 Vs 11:50:00 Voltage Offset Correction: v_off_ini = -0.000000137 V, v_off_fin = -0.000000518 V 11:50:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000188319 Vs 11:50:09 Voltage Offset Correction: v_off_ini = 0.000000657 V, v_off_fin = 0.000000128 V 11:50:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000189050 Vs 11:50:18 Voltage Offset Correction: v_off_ini = 0.000000113 V, v_off_fin = 0.000000646 V 11:50:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000187219 Vs 11:50:26 Voltage Offset Correction: v_off_ini = 0.000000212 V, v_off_fin = 0.000001224 V 11:50:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000187449 Vs 11:50:35 Voltage Offset Correction: v_off_ini = -0.000000273 V, v_off_fin = -0.000001082 V 11:50:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000188502 Vs 11:50:43 Voltage Offset Correction: v_off_ini = -0.000000174 V, v_off_fin = -0.000000448 V 11:50:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000186585 Vs 11:50:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000187824 +- 0.000000517 Vs 11:50:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000187824 +- 0.000000517 Vs BL = 0.00187824 +- 0.00000517 Tm 11:50:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00188 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00188 0.00001 0.00188 0.00000 11:50:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00188 0.00001 SL = 0.0018782 +- 0.0000052 Tm^2/m^n 11:50:48 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0018782 +- 0.0000052 Tm^2/m^n 11:50:50 Magnet Current, Imag = 299.9769 A Vtrans = 2.999769 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:50:51 Magnet Current, Imag = 299.9678 A Vtrans = 2.999678 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:50:52 Magnet Current, Imag = 299.9854 A Vtrans = 2.999854 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:50:53 Magnet Current, Imag = 299.9816 A Vtrans = 2.999816 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:50:53 Magnet Current Measurement: Imag = 299.9779 +- 0.0066 A 11:50:53 Magnet current ramping to 290.0000 A... 11:51:28 Magnet Current, Imag = 290.0310 A Vtrans = 2.900310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:51:29 Magnet Current, Imag = 290.0354 A Vtrans = 2.900354 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:51:30 Magnet Current, Imag = 290.0287 A Vtrans = 2.900287 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:51:31 Magnet Current, Imag = 290.0360 A Vtrans = 2.900360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:51:31 Magnet Current Measurement: Imag = 290.0328 +- 0.0030 A 11:51:31 Magnetic Field Measurement Measuring the magnet strength... 11:51:31 Integrated Voltage Measurement... 11:51:45 Voltage Offset Correction: v_off_ini = -0.000000648 V, v_off_fin = -0.000000288 V 11:51:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000109355 Vs 11:51:53 Voltage Offset Correction: v_off_ini = -0.000000882 V, v_off_fin = 0.000000031 V 11:51:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000109625 Vs 11:52:02 Voltage Offset Correction: v_off_ini = -0.000000333 V, v_off_fin = -0.000000478 V 11:52:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000109101 Vs 11:52:10 Voltage Offset Correction: v_off_ini = -0.000000141 V, v_off_fin = 0.000000630 V 11:52:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000108718 Vs 11:52:19 Voltage Offset Correction: v_off_ini = 0.000000197 V, v_off_fin = 0.000000561 V 11:52:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000108174 Vs 11:52:28 Voltage Offset Correction: v_off_ini = 0.000000230 V, v_off_fin = 0.000000018 V 11:52:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000107165 Vs 11:52:36 Voltage Offset Correction: v_off_ini = 0.000000380 V, v_off_fin = 0.000000483 V 11:52:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000108702 Vs 11:52:45 Voltage Offset Correction: v_off_ini = 0.000000052 V, v_off_fin = 0.000000127 V 11:52:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000110234 Vs 11:52:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000108884 +- 0.000000739 Vs 11:52:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000108884 +- 0.000000739 Vs BL = 0.00108884 +- 0.00000739 Tm 11:52:50 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00109 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00109 0.00001 0.00109 0.00000 11:52:50 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00109 0.00001 SL = 0.0010888 +- 0.0000074 Tm^2/m^n 11:52:50 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0010888 +- 0.0000074 Tm^2/m^n 11:52:51 Magnet Current, Imag = 290.0437 A Vtrans = 2.900437 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:52:52 Magnet Current, Imag = 290.0353 A Vtrans = 2.900353 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:52:53 Magnet Current, Imag = 290.0296 A Vtrans = 2.900296 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:52:54 Magnet Current, Imag = 290.0262 A Vtrans = 2.900262 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:52:55 Magnet Current Measurement: Imag = 290.0337 +- 0.0066 A 11:52:55 Magnet current ramping to 280.0000 A... 11:53:29 Magnet Current, Imag = 279.9583 A Vtrans = 2.799583 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:53:30 Magnet Current, Imag = 279.9604 A Vtrans = 2.799604 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:53:32 Magnet Current, Imag = 279.9595 A Vtrans = 2.799595 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:53:33 Magnet Current, Imag = 279.9605 A Vtrans = 2.799605 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:53:33 Magnet Current Measurement: Imag = 279.9597 +- 0.0009 A 11:53:33 Magnetic Field Measurement Measuring the magnet strength... 11:53:33 Integrated Voltage Measurement... 11:53:46 Voltage Offset Correction: v_off_ini = -0.000000311 V, v_off_fin = -0.000000835 V 11:53:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000058266 Vs 11:53:55 Voltage Offset Correction: v_off_ini = 0.000000445 V, v_off_fin = 0.000001000 V 11:53:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000057701 Vs 11:54:03 Voltage Offset Correction: v_off_ini = 0.000001116 V, v_off_fin = 0.000000506 V 11:54:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000059169 Vs 11:54:12 Voltage Offset Correction: v_off_ini = 0.000000885 V, v_off_fin = 0.000000524 V 11:54:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000057680 Vs 11:54:20 Voltage Offset Correction: v_off_ini = 0.000000612 V, v_off_fin = 0.000000884 V 11:54:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000060633 Vs 11:54:29 Voltage Offset Correction: v_off_ini = 0.000000421 V, v_off_fin = 0.000000335 V 11:54:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000058035 Vs 11:54:38 Voltage Offset Correction: v_off_ini = -0.000000215 V, v_off_fin = 0.000000257 V 11:54:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000057465 Vs 11:54:46 Voltage Offset Correction: v_off_ini = -0.000000258 V, v_off_fin = -0.000000311 V 11:54:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000059005 Vs 11:54:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000058494 +- 0.000000509 Vs 11:54:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000058494 +- 0.000000509 Vs BL = 0.00058494 +- 0.00000509 Tm 11:54:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00058 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00058 0.00001 0.00058 0.00000 11:54:51 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00058 0.00001 SL = 0.0005849 +- 0.0000051 Tm^2/m^n 11:54:51 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0005849 +- 0.0000051 Tm^2/m^n 11:54:52 Magnet Current, Imag = 279.9514 A Vtrans = 2.799514 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:54:53 Magnet Current, Imag = 279.9601 A Vtrans = 2.799601 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:54:55 Magnet Current, Imag = 279.9498 A Vtrans = 2.799498 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:54:56 Magnet Current, Imag = 279.9552 A Vtrans = 2.799552 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:54:56 Magnet Current Measurement: Imag = 279.9541 +- 0.0040 A 11:54:56 Magnet current ramping to 273.0000 A... 11:55:30 Magnet Current, Imag = 273.1752 A Vtrans = 2.731752 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:55:31 Magnet Current, Imag = 273.1647 A Vtrans = 2.731647 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:55:32 Magnet Current, Imag = 273.1759 A Vtrans = 2.731759 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:55:33 Magnet Current, Imag = 273.1614 A Vtrans = 2.731614 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:55:33 Magnet Current Measurement: Imag = 273.1693 +- 0.0064 A 11:55:33 Magnetic Field Measurement Measuring the magnet strength... 11:55:33 Integrated Voltage Measurement... 11:55:47 Voltage Offset Correction: v_off_ini = 0.000000058 V, v_off_fin = -0.000000162 V 11:55:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000039801 Vs 11:55:55 Voltage Offset Correction: v_off_ini = -0.000000185 V, v_off_fin = 0.000000360 V 11:55:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000040941 Vs 11:56:04 Voltage Offset Correction: v_off_ini = -0.000000376 V, v_off_fin = -0.000001150 V 11:56:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000041644 Vs 11:56:12 Voltage Offset Correction: v_off_ini = -0.000000289 V, v_off_fin = -0.000000342 V 11:56:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000040450 Vs 11:56:21 Voltage Offset Correction: v_off_ini = -0.000000583 V, v_off_fin = -0.000000416 V 11:56:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000041129 Vs 11:56:30 Voltage Offset Correction: v_off_ini = -0.000000419 V, v_off_fin = -0.000000166 V 11:56:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000044185 Vs 11:56:38 Voltage Offset Correction: v_off_ini = -0.000000367 V, v_off_fin = -0.000000067 V 11:56:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000040212 Vs 11:56:47 Voltage Offset Correction: v_off_ini = -0.000000823 V, v_off_fin = -0.000000583 V 11:56:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000039264 Vs 11:56:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000040953 +- 0.000001087 Vs 11:56:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000040953 +- 0.000001087 Vs BL = 0.00040953 +- 0.00001087 Tm 11:56:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00041 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00041 0.00001 0.00041 0.00000 11:56:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00041 0.00001 SL = 0.0004095 +- 0.0000109 Tm^2/m^n 11:56:52 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0004095 +- 0.0000109 Tm^2/m^n 11:56:53 Magnet Current, Imag = 273.1724 A Vtrans = 2.731724 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:56:54 Magnet Current, Imag = 273.1656 A Vtrans = 2.731656 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:56:55 Magnet Current, Imag = 273.1770 A Vtrans = 2.731770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:56:56 Magnet Current, Imag = 273.1534 A Vtrans = 2.731534 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:56:56 Magnet Current Measurement: Imag = 273.1671 +- 0.0089 A 11:56:57 Magnet current ramping to 270.0000 A... 11:57:30 Magnet Current, Imag = 270.0567 A Vtrans = 2.700567 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:57:31 Magnet Current, Imag = 270.0564 A Vtrans = 2.700564 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:57:32 Magnet Current, Imag = 270.0558 A Vtrans = 2.700558 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:57:33 Magnet Current, Imag = 270.0496 A Vtrans = 2.700496 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:57:34 Magnet Current Measurement: Imag = 270.0546 +- 0.0029 A 11:57:34 Magnetic Field Measurement Measuring the magnet strength... 11:57:34 Integrated Voltage Measurement... 11:57:47 Voltage Offset Correction: v_off_ini = -0.000000533 V, v_off_fin = 0.000000045 V 11:57:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000034878 Vs 11:57:55 Voltage Offset Correction: v_off_ini = -0.000000445 V, v_off_fin = 0.000000235 V 11:57:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000033497 Vs 11:58:04 Voltage Offset Correction: v_off_ini = -0.000000251 V, v_off_fin = 0.000000330 V 11:58:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000032669 Vs 11:58:13 Voltage Offset Correction: v_off_ini = -0.000000945 V, v_off_fin = -0.000000540 V 11:58:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000033215 Vs 11:58:21 Voltage Offset Correction: v_off_ini = -0.000000501 V, v_off_fin = -0.000000040 V 11:58:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000034310 Vs 11:58:30 Voltage Offset Correction: v_off_ini = -0.000000306 V, v_off_fin = -0.000000161 V 11:58:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000032911 Vs 11:58:38 Voltage Offset Correction: v_off_ini = -0.000000815 V, v_off_fin = -0.000000865 V 11:58:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000035376 Vs 11:58:47 Voltage Offset Correction: v_off_ini = -0.000000526 V, v_off_fin = -0.000001062 V 11:58:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000034400 Vs 11:58:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000033907 +- 0.000000718 Vs 11:58:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000033907 +- 0.000000718 Vs BL = 0.00033907 +- 0.00000718 Tm 11:58:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00034 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00034 0.00001 0.00034 0.00000 11:58:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00034 0.00001 SL = 0.0003391 +- 0.0000072 Tm^2/m^n 11:58:52 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0003391 +- 0.0000072 Tm^2/m^n 11:58:53 Magnet Current, Imag = 270.0562 A Vtrans = 2.700562 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:58:54 Magnet Current, Imag = 270.0480 A Vtrans = 2.700480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:58:55 Magnet Current, Imag = 270.0624 A Vtrans = 2.700624 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:58:57 Magnet Current, Imag = 270.0510 A Vtrans = 2.700510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:58:57 Magnet Current Measurement: Imag = 270.0544 +- 0.0055 A 11:58:57 Magnet current ramping to 260.0000 A... 11:59:31 Magnet Current, Imag = 259.9836 A Vtrans = 2.599836 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:59:32 Magnet Current, Imag = 259.9884 A Vtrans = 2.599884 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:59:34 Magnet Current, Imag = 259.9648 A Vtrans = 2.599648 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:59:35 Magnet Current, Imag = 259.9819 A Vtrans = 2.599819 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:59:35 Magnet Current Measurement: Imag = 259.9797 +- 0.0089 A 11:59:35 Magnetic Field Measurement Measuring the magnet strength... 11:59:35 Integrated Voltage Measurement... 11:59:48 Voltage Offset Correction: v_off_ini = -0.000001848 V, v_off_fin = -0.000002289 V 11:59:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000023804 Vs 11:59:57 Voltage Offset Correction: v_off_ini = -0.000001553 V, v_off_fin = -0.000001278 V 11:59:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000023136 Vs 12:00:05 Voltage Offset Correction: v_off_ini = -0.000001676 V, v_off_fin = -0.000001806 V 12:00:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000019857 Vs 12:00:14 Voltage Offset Correction: v_off_ini = -0.000001275 V, v_off_fin = -0.000001247 V 12:00:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000022273 Vs 12:00:22 Voltage Offset Correction: v_off_ini = -0.000001336 V, v_off_fin = -0.000000643 V 12:00:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000022668 Vs 12:00:31 Voltage Offset Correction: v_off_ini = -0.000001010 V, v_off_fin = -0.000001385 V 12:00:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000020074 Vs 12:00:40 Voltage Offset Correction: v_off_ini = -0.000000528 V, v_off_fin = -0.000001276 V 12:00:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000019860 Vs 12:00:48 Voltage Offset Correction: v_off_ini = -0.000001226 V, v_off_fin = -0.000001794 V 12:00:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000021797 Vs 12:00:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000021684 +- 0.000001049 Vs 12:00:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000021684 +- 0.000001049 Vs BL = 0.00021684 +- 0.00001049 Tm 12:00:53 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00022 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00022 0.00001 0.00022 0.00000 12:00:53 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00022 0.00001 SL = 0.0002168 +- 0.0000105 Tm^2/m^n 12:00:53 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0002168 +- 0.0000105 Tm^2/m^n 12:00:54 Magnet Current, Imag = 259.9823 A Vtrans = 2.599823 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:00:56 Magnet Current, Imag = 259.9820 A Vtrans = 2.599820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:00:57 Magnet Current, Imag = 259.9733 A Vtrans = 2.599733 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:00:58 Magnet Current, Imag = 259.9835 A Vtrans = 2.599835 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:00:58 Magnet Current Measurement: Imag = 259.9803 +- 0.0041 A 12:00:58 Magnet current ramping to 250.0000 A... 12:01:33 Magnet Current, Imag = 250.0283 A Vtrans = 2.500283 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:01:34 Magnet Current, Imag = 250.0173 A Vtrans = 2.500173 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:01:35 Magnet Current, Imag = 250.0219 A Vtrans = 2.500219 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:01:36 Magnet Current, Imag = 250.0378 A Vtrans = 2.500378 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:01:36 Magnet Current Measurement: Imag = 250.0263 +- 0.0077 A 12:01:36 Magnetic Field Measurement Measuring the magnet strength... 12:01:36 Integrated Voltage Measurement... 12:01:49 Voltage Offset Correction: v_off_ini = -0.000000960 V, v_off_fin = -0.000000100 V 12:01:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000016347 Vs 12:01:58 Voltage Offset Correction: v_off_ini = -0.000001380 V, v_off_fin = -0.000000309 V 12:01:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000014704 Vs 12:02:07 Voltage Offset Correction: v_off_ini = -0.000000832 V, v_off_fin = -0.000000178 V 12:02:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000014466 Vs 12:02:15 Voltage Offset Correction: v_off_ini = -0.000001154 V, v_off_fin = -0.000002708 V 12:02:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000015397 Vs 12:02:24 Voltage Offset Correction: v_off_ini = -0.000000890 V, v_off_fin = -0.000001600 V 12:02:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000015614 Vs 12:02:32 Voltage Offset Correction: v_off_ini = -0.000000970 V, v_off_fin = -0.000001459 V 12:02:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000017620 Vs 12:02:41 Voltage Offset Correction: v_off_ini = -0.000001012 V, v_off_fin = 0.000000194 V 12:02:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000017434 Vs 12:02:50 Voltage Offset Correction: v_off_ini = -0.000001122 V, v_off_fin = -0.000000634 V 12:02:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000016658 Vs 12:02:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000016030 +- 0.000000842 Vs 12:02:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000016030 +- 0.000000842 Vs BL = 0.00016030 +- 0.00000842 Tm 12:02:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00016 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00016 0.00001 0.00016 0.00000 12:02:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00016 0.00001 SL = 0.0001603 +- 0.0000084 Tm^2/m^n 12:02:55 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0001603 +- 0.0000084 Tm^2/m^n 12:02:56 Magnet Current, Imag = 250.0196 A Vtrans = 2.500196 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:02:57 Magnet Current, Imag = 250.0193 A Vtrans = 2.500193 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:02:58 Magnet Current, Imag = 250.0113 A Vtrans = 2.500113 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:02:59 Magnet Current, Imag = 250.0241 A Vtrans = 2.500241 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:02:59 Magnet Current Measurement: Imag = 250.0186 +- 0.0046 A 12:02:59 Magnet current ramping to 240.0000 A... 12:03:34 Magnet Current, Imag = 239.9579 A Vtrans = 2.399579 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:03:35 Magnet Current, Imag = 239.9648 A Vtrans = 2.399648 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:03:36 Magnet Current, Imag = 239.9605 A Vtrans = 2.399605 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:03:38 Magnet Current, Imag = 239.9491 A Vtrans = 2.399491 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:03:38 Magnet Current Measurement: Imag = 239.9581 +- 0.0057 A 12:03:38 Magnetic Field Measurement Measuring the magnet strength... 12:03:38 Integrated Voltage Measurement... 12:03:51 Voltage Offset Correction: v_off_ini = 0.000001032 V, v_off_fin = 0.000001153 V 12:03:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000007890 Vs 12:03:59 Voltage Offset Correction: v_off_ini = 0.000001699 V, v_off_fin = 0.000001383 V 12:03:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000013470 Vs 12:04:08 Voltage Offset Correction: v_off_ini = 0.000001110 V, v_off_fin = 0.000000647 V 12:04:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000010533 Vs 12:04:17 Voltage Offset Correction: v_off_ini = 0.000000655 V, v_off_fin = 0.000001279 V 12:04:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000008199 Vs 12:04:25 Voltage Offset Correction: v_off_ini = 0.000000419 V, v_off_fin = 0.000000357 V 12:04:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000009209 Vs 12:04:34 Voltage Offset Correction: v_off_ini = 0.000001098 V, v_off_fin = 0.000000430 V 12:04:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000010066 Vs 12:04:42 Voltage Offset Correction: v_off_ini = 0.000000603 V, v_off_fin = 0.000000962 V 12:04:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000011209 Vs 12:04:51 Voltage Offset Correction: v_off_ini = 0.000000531 V, v_off_fin = 0.000000569 V 12:04:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000010838 Vs 12:04:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000010177 +- 0.000000693 Vs 12:04:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000010177 +- 0.000000693 Vs BL = 0.00010177 +- 0.00000693 Tm 12:04:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00010 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00010 0.00001 0.00010 0.00000 12:04:56 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00010 0.00001 SL = 0.0001018 +- 0.0000069 Tm^2/m^n 12:04:56 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0001018 +- 0.0000069 Tm^2/m^n 12:04:57 Magnet Current, Imag = 239.9638 A Vtrans = 2.399638 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:04:58 Magnet Current, Imag = 239.9582 A Vtrans = 2.399582 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:05:00 Magnet Current, Imag = 239.9562 A Vtrans = 2.399562 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:05:01 Magnet Current, Imag = 239.9551 A Vtrans = 2.399551 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:05:01 Magnet Current Measurement: Imag = 239.9583 +- 0.0034 A 12:05:01 Magnet current ramping to 230.0000 A... 12:05:35 Magnet Current, Imag = 230.1719 A Vtrans = 2.301719 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:05:37 Magnet Current, Imag = 230.1652 A Vtrans = 2.301652 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:05:38 Magnet Current, Imag = 230.1710 A Vtrans = 2.301710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:05:39 Magnet Current, Imag = 230.1669 A Vtrans = 2.301669 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:05:39 Magnet Current Measurement: Imag = 230.1687 +- 0.0028 A 12:05:39 Magnetic Field Measurement Measuring the magnet strength... 12:05:39 Integrated Voltage Measurement... 12:05:52 Voltage Offset Correction: v_off_ini = -0.000002127 V, v_off_fin = -0.000001285 V 12:05:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000007221 Vs 12:06:01 Voltage Offset Correction: v_off_ini = -0.000001575 V, v_off_fin = -0.000000966 V 12:06:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000008898 Vs 12:06:09 Voltage Offset Correction: v_off_ini = -0.000001599 V, v_off_fin = -0.000000996 V 12:06:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000009446 Vs 12:06:18 Voltage Offset Correction: v_off_ini = -0.000001227 V, v_off_fin = -0.000000050 V 12:06:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000006193 Vs 12:06:27 Voltage Offset Correction: v_off_ini = -0.000001340 V, v_off_fin = -0.000000885 V 12:06:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000007187 Vs 12:06:35 Voltage Offset Correction: v_off_ini = -0.000001117 V, v_off_fin = 0.000000009 V 12:06:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000004836 Vs 12:06:44 Voltage Offset Correction: v_off_ini = -0.000000882 V, v_off_fin = -0.000002114 V 12:06:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000009162 Vs 12:06:53 Voltage Offset Correction: v_off_ini = -0.000001331 V, v_off_fin = -0.000000806 V 12:06:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000006147 Vs 12:06:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000007386 +- 0.000000807 Vs 12:06:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000007386 +- 0.000000807 Vs BL = 0.00007386 +- 0.00000807 Tm 12:06:57 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00007 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00007 0.00001 0.00007 0.00000 12:06:57 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00007 0.00001 SL = 0.0000739 +- 0.0000081 Tm^2/m^n 12:06:57 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0000739 +- 0.0000081 Tm^2/m^n 12:06:59 Magnet Current, Imag = 230.1702 A Vtrans = 2.301702 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:07:00 Magnet Current, Imag = 230.1674 A Vtrans = 2.301674 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:07:01 Magnet Current, Imag = 230.1662 A Vtrans = 2.301662 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:07:02 Magnet Current, Imag = 230.1685 A Vtrans = 2.301685 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:07:02 Magnet Current Measurement: Imag = 230.1681 +- 0.0015 A 12:07:02 Magnet current ramping to 220.0000 A... 12:07:37 Magnet Current, Imag = 220.0751 A Vtrans = 2.200751 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:07:38 Magnet Current, Imag = 220.0780 A Vtrans = 2.200780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:07:39 Magnet Current, Imag = 220.0675 A Vtrans = 2.200675 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:07:40 Magnet Current, Imag = 220.0672 A Vtrans = 2.200672 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:07:40 Magnet Current Measurement: Imag = 220.0719 +- 0.0047 A 12:07:40 Magnetic Field Measurement Measuring the magnet strength... 12:07:41 Integrated Voltage Measurement... 12:07:54 Voltage Offset Correction: v_off_ini = -0.000001114 V, v_off_fin = -0.000001080 V 12:07:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000003438 Vs 12:08:02 Voltage Offset Correction: v_off_ini = -0.000001377 V, v_off_fin = 0.000000092 V 12:08:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000004197 Vs 12:08:11 Voltage Offset Correction: v_off_ini = -0.000000600 V, v_off_fin = 0.000000045 V 12:08:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000004057 Vs 12:08:19 Voltage Offset Correction: v_off_ini = -0.000000272 V, v_off_fin = 0.000000112 V 12:08:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000002900 Vs 12:08:28 Voltage Offset Correction: v_off_ini = -0.000000523 V, v_off_fin = -0.000001276 V 12:08:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000004272 Vs 12:08:37 Voltage Offset Correction: v_off_ini = -0.000001305 V, v_off_fin = -0.000001522 V 12:08:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000004482 Vs 12:08:45 Voltage Offset Correction: v_off_ini = -0.000001166 V, v_off_fin = -0.000001450 V 12:08:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000003733 Vs 12:08:54 Voltage Offset Correction: v_off_ini = -0.000000803 V, v_off_fin = 0.000000489 V 12:08:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000004583 Vs 12:08:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000003958 +- 0.000000341 Vs 12:08:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000003958 +- 0.000000341 Vs BL = 0.00003958 +- 0.00000341 Tm 12:08:59 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00004 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00004 0.00000 0.00004 0.00000 12:08:59 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00004 0.00000 SL = 0.0000396 +- 0.0000034 Tm^2/m^n 12:08:59 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0000396 +- 0.0000034 Tm^2/m^n 12:09:00 Magnet Current, Imag = 220.0753 A Vtrans = 2.200753 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:09:01 Magnet Current, Imag = 220.0647 A Vtrans = 2.200647 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:09:02 Magnet Current, Imag = 220.0795 A Vtrans = 2.200795 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:09:04 Magnet Current, Imag = 220.0676 A Vtrans = 2.200676 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:09:04 Magnet Current Measurement: Imag = 220.0718 +- 0.0059 A 12:09:04 Magnet current ramping to 210.0000 A... 12:09:38 Magnet Current, Imag = 210.1076 A Vtrans = 2.101076 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:09:39 Magnet Current, Imag = 210.1163 A Vtrans = 2.101163 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:09:41 Magnet Current, Imag = 210.1210 A Vtrans = 2.101210 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:09:42 Magnet Current, Imag = 210.1312 A Vtrans = 2.101312 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:09:42 Magnet Current Measurement: Imag = 210.1190 +- 0.0085 A 12:09:42 Magnetic Field Measurement Measuring the magnet strength... 12:09:42 Integrated Voltage Measurement... 12:09:55 Voltage Offset Correction: v_off_ini = -0.000000322 V, v_off_fin = -0.000000552 V 12:09:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000001022 Vs 12:10:04 Voltage Offset Correction: v_off_ini = -0.000000664 V, v_off_fin = -0.000000857 V 12:10:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000000326 Vs 12:10:12 Voltage Offset Correction: v_off_ini = -0.000000775 V, v_off_fin = -0.000001091 V 12:10:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000952 Vs 12:10:21 Voltage Offset Correction: v_off_ini = -0.000001059 V, v_off_fin = -0.000001206 V 12:10:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000000701 Vs 12:10:29 Voltage Offset Correction: v_off_ini = -0.000001378 V, v_off_fin = -0.000001285 V 12:10:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000002722 Vs 12:10:38 Voltage Offset Correction: v_off_ini = -0.000001336 V, v_off_fin = -0.000000317 V 12:10:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000001025 Vs 12:10:47 Voltage Offset Correction: v_off_ini = -0.000000540 V, v_off_fin = 0.000000201 V 12:10:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000000587 Vs 12:10:55 Voltage Offset Correction: v_off_ini = -0.000000788 V, v_off_fin = -0.000000668 V 12:10:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000000252 Vs 12:10:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000720 +- 0.000000753 Vs 12:10:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000000720 +- 0.000000753 Vs BL = 0.00000720 +- 0.00000753 Tm 12:11:00 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00001 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00001 0.00001 0.00001 0.00000 12:11:00 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00001 0.00001 SL = 0.0000072 +- 0.0000075 Tm^2/m^n 12:11:00 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0000072 +- 0.0000075 Tm^2/m^n 12:11:01 Magnet Current, Imag = 210.1277 A Vtrans = 2.101277 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:11:03 Magnet Current, Imag = 210.1178 A Vtrans = 2.101178 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:11:04 Magnet Current, Imag = 210.1123 A Vtrans = 2.101123 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:11:05 Magnet Current, Imag = 210.1141 A Vtrans = 2.101141 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:11:05 Magnet Current Measurement: Imag = 210.1180 +- 0.0060 A 12:11:05 Magnet current ramping to 200.0000 A... 12:11:40 Magnet Current, Imag = 200.0569 A Vtrans = 2.000569 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:11:41 Magnet Current, Imag = 200.0533 A Vtrans = 2.000533 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:11:42 Magnet Current, Imag = 200.0469 A Vtrans = 2.000469 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:11:43 Magnet Current, Imag = 200.0584 A Vtrans = 2.000584 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:11:43 Magnet Current Measurement: Imag = 200.0539 +- 0.0044 A 12:11:43 Magnetic Field Measurement Measuring the magnet strength... 12:11:43 Integrated Voltage Measurement... 12:11:56 Voltage Offset Correction: v_off_ini = -0.000000024 V, v_off_fin = 0.000000087 V 12:11:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000001337 Vs 12:12:05 Voltage Offset Correction: v_off_ini = -0.000000340 V, v_off_fin = -0.000000458 V 12:12:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000002315 Vs 12:12:14 Voltage Offset Correction: v_off_ini = -0.000000773 V, v_off_fin = -0.000000283 V 12:12:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000000095 Vs 12:12:22 Voltage Offset Correction: v_off_ini = -0.000000922 V, v_off_fin = -0.000000140 V 12:12:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000002002 Vs 12:12:31 Voltage Offset Correction: v_off_ini = -0.000001205 V, v_off_fin = -0.000002358 V 12:12:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000379 Vs 12:12:39 Voltage Offset Correction: v_off_ini = -0.000001128 V, v_off_fin = -0.000001383 V 12:12:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000000779 Vs 12:12:48 Voltage Offset Correction: v_off_ini = -0.000000816 V, v_off_fin = -0.000001109 V 12:12:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000002339 Vs 12:12:57 Voltage Offset Correction: v_off_ini = -0.000000486 V, v_off_fin = -0.000000796 V 12:12:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000002587 Vs 12:12:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000001190 +- 0.000001137 Vs 12:12:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000001190 +- 0.000001137 Vs BL = -0.00001190 +- 0.00001137 Tm 12:13:01 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00001 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00001 0.00001 -0.00001 0.00000 12:13:01 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00001 0.00001 SL = -0.0000119 +- 0.0000114 Tm^2/m^n 12:13:01 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0000119 +- 0.0000114 Tm^2/m^n 12:13:03 Magnet Current, Imag = 200.0529 A Vtrans = 2.000529 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:13:04 Magnet Current, Imag = 200.0427 A Vtrans = 2.000427 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:13:05 Magnet Current, Imag = 200.0450 A Vtrans = 2.000450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:13:06 Magnet Current, Imag = 200.0468 A Vtrans = 2.000468 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:13:06 Magnet Current Measurement: Imag = 200.0468 +- 0.0038 A 12:13:06 Magnet current ramping to 190.0000 A... 12:13:41 Magnet Current, Imag = 190.1644 A Vtrans = 1.901644 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:13:42 Magnet Current, Imag = 190.1712 A Vtrans = 1.901712 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:13:43 Magnet Current, Imag = 190.1629 A Vtrans = 1.901629 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:13:45 Magnet Current, Imag = 190.1669 A Vtrans = 1.901669 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:13:45 Magnet Current Measurement: Imag = 190.1663 +- 0.0031 A 12:13:45 Magnetic Field Measurement Measuring the magnet strength... 12:13:45 Integrated Voltage Measurement... 12:13:58 Voltage Offset Correction: v_off_ini = 0.000000438 V, v_off_fin = -0.000000305 V 12:13:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000005926 Vs 12:14:06 Voltage Offset Correction: v_off_ini = 0.000000407 V, v_off_fin = 0.000000262 V 12:14:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000003352 Vs 12:14:15 Voltage Offset Correction: v_off_ini = 0.000000273 V, v_off_fin = 0.000000795 V 12:14:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000004925 Vs 12:14:24 Voltage Offset Correction: v_off_ini = 0.000000465 V, v_off_fin = 0.000001395 V 12:14:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000005274 Vs 12:14:32 Voltage Offset Correction: v_off_ini = 0.000000356 V, v_off_fin = 0.000000874 V 12:14:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000004687 Vs 12:14:41 Voltage Offset Correction: v_off_ini = 0.000000584 V, v_off_fin = 0.000000612 V 12:14:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000005947 Vs 12:14:49 Voltage Offset Correction: v_off_ini = 0.000000322 V, v_off_fin = -0.000000364 V 12:14:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000003676 Vs 12:14:58 Voltage Offset Correction: v_off_ini = 0.000000206 V, v_off_fin = -0.000000241 V 12:14:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000002679 Vs 12:14:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000004558 +- 0.000000834 Vs 12:14:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000004558 +- 0.000000834 Vs BL = -0.00004558 +- 0.00000834 Tm 12:15:03 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00005 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00005 0.00001 -0.00005 0.00000 12:15:03 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00005 0.00001 SL = -0.0000456 +- 0.0000083 Tm^2/m^n 12:15:03 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0000456 +- 0.0000083 Tm^2/m^n 12:15:04 Magnet Current, Imag = 190.1571 A Vtrans = 1.901571 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:15:05 Magnet Current, Imag = 190.1706 A Vtrans = 1.901706 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:15:06 Magnet Current, Imag = 190.1711 A Vtrans = 1.901711 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:15:08 Magnet Current, Imag = 190.1770 A Vtrans = 1.901770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:15:08 Magnet Current Measurement: Imag = 190.1689 +- 0.0073 A 12:15:08 Magnet current ramping to 180.0000 A... 12:15:42 Magnet Current, Imag = 179.8158 A Vtrans = 1.798158 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:15:44 Magnet Current, Imag = 179.8157 A Vtrans = 1.798157 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:15:45 Magnet Current, Imag = 179.8194 A Vtrans = 1.798194 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:15:46 Magnet Current, Imag = 179.8150 A Vtrans = 1.798150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:15:46 Magnet Current Measurement: Imag = 179.8165 +- 0.0017 A 12:15:46 Magnetic Field Measurement Measuring the magnet strength... 12:15:46 Integrated Voltage Measurement... 12:15:59 Voltage Offset Correction: v_off_ini = -0.000002214 V, v_off_fin = -0.000002674 V 12:15:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000005671 Vs 12:16:08 Voltage Offset Correction: v_off_ini = -0.000002904 V, v_off_fin = -0.000001733 V 12:16:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000007051 Vs 12:16:16 Voltage Offset Correction: v_off_ini = -0.000002757 V, v_off_fin = -0.000001170 V 12:16:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000008390 Vs 12:16:25 Voltage Offset Correction: v_off_ini = -0.000002898 V, v_off_fin = -0.000002361 V 12:16:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000005560 Vs 12:16:34 Voltage Offset Correction: v_off_ini = -0.000002659 V, v_off_fin = -0.000001534 V 12:16:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000006791 Vs 12:16:42 Voltage Offset Correction: v_off_ini = -0.000002452 V, v_off_fin = -0.000001604 V 12:16:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000004517 Vs 12:16:51 Voltage Offset Correction: v_off_ini = -0.000002070 V, v_off_fin = -0.000001463 V 12:16:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000007438 Vs 12:16:59 Voltage Offset Correction: v_off_ini = -0.000001855 V, v_off_fin = -0.000000784 V 12:16:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000008154 Vs 12:16:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000006697 +- 0.000000788 Vs 12:16:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000006697 +- 0.000000788 Vs BL = -0.00006697 +- 0.00000788 Tm 12:17:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00007 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00007 0.00001 -0.00007 0.00000 12:17:04 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00007 0.00001 SL = -0.0000670 +- 0.0000079 Tm^2/m^n 12:17:04 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0000670 +- 0.0000079 Tm^2/m^n 12:17:05 Magnet Current, Imag = 179.8231 A Vtrans = 1.798231 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:17:07 Magnet Current, Imag = 179.8158 A Vtrans = 1.798158 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:17:08 Magnet Current, Imag = 179.8145 A Vtrans = 1.798145 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:17:09 Magnet Current, Imag = 179.8117 A Vtrans = 1.798117 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:17:09 Magnet Current Measurement: Imag = 179.8163 +- 0.0042 A 12:17:09 Magnet current ramping to 170.0000 A... 12:17:44 Magnet Current, Imag = 169.8523 A Vtrans = 1.698523 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:17:45 Magnet Current, Imag = 169.8633 A Vtrans = 1.698633 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:17:46 Magnet Current, Imag = 169.8670 A Vtrans = 1.698670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:17:47 Magnet Current, Imag = 169.8646 A Vtrans = 1.698646 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:17:47 Magnet Current Measurement: Imag = 169.8618 +- 0.0056 A 12:17:47 Magnetic Field Measurement Measuring the magnet strength... 12:17:47 Integrated Voltage Measurement... 12:18:00 Voltage Offset Correction: v_off_ini = -0.000000939 V, v_off_fin = -0.000002021 V 12:18:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000009963 Vs 12:18:09 Voltage Offset Correction: v_off_ini = -0.000000967 V, v_off_fin = -0.000000627 V 12:18:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000008982 Vs 12:18:18 Voltage Offset Correction: v_off_ini = -0.000001286 V, v_off_fin = -0.000001275 V 12:18:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000009557 Vs 12:18:26 Voltage Offset Correction: v_off_ini = -0.000001312 V, v_off_fin = -0.000001976 V 12:18:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000008838 Vs 12:18:35 Voltage Offset Correction: v_off_ini = -0.000001478 V, v_off_fin = -0.000001283 V 12:18:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000008048 Vs 12:18:44 Voltage Offset Correction: v_off_ini = -0.000001000 V, v_off_fin = -0.000000943 V 12:18:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000006581 Vs 12:18:52 Voltage Offset Correction: v_off_ini = -0.000000928 V, v_off_fin = -0.000001071 V 12:18:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000008227 Vs 12:19:01 Voltage Offset Correction: v_off_ini = -0.000000978 V, v_off_fin = -0.000000814 V 12:19:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000008789 Vs 12:19:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000008623 +- 0.000000833 Vs 12:19:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000008623 +- 0.000000833 Vs BL = -0.00008623 +- 0.00000833 Tm 12:19:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00009 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00009 0.00001 -0.00009 0.00000 12:19:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00009 0.00001 SL = -0.0000862 +- 0.0000083 Tm^2/m^n 12:19:06 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0000862 +- 0.0000083 Tm^2/m^n 12:19:07 Magnet Current, Imag = 169.8370 A Vtrans = 1.698370 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:19:08 Magnet Current, Imag = 169.8564 A Vtrans = 1.698564 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:19:09 Magnet Current, Imag = 169.8614 A Vtrans = 1.698614 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:19:10 Magnet Current, Imag = 169.8583 A Vtrans = 1.698583 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:19:10 Magnet Current Measurement: Imag = 169.8533 +- 0.0096 A 12:19:11 Magnet current ramping to 160.0000 A... 12:19:45 Magnet Current, Imag = 159.8056 A Vtrans = 1.598056 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:19:46 Magnet Current, Imag = 159.8025 A Vtrans = 1.598025 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:19:47 Magnet Current, Imag = 159.7990 A Vtrans = 1.597990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:19:49 Magnet Current, Imag = 159.8071 A Vtrans = 1.598071 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:19:49 Magnet Current Measurement: Imag = 159.8036 +- 0.0031 A 12:19:49 Magnetic Field Measurement Measuring the magnet strength... 12:19:49 Integrated Voltage Measurement... 12:20:02 Voltage Offset Correction: v_off_ini = -0.000002760 V, v_off_fin = -0.000003177 V 12:20:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000011481 Vs 12:20:10 Voltage Offset Correction: v_off_ini = -0.000003007 V, v_off_fin = -0.000002941 V 12:20:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000009908 Vs 12:20:19 Voltage Offset Correction: v_off_ini = -0.000002937 V, v_off_fin = -0.000002281 V 12:20:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000010662 Vs 12:20:28 Voltage Offset Correction: v_off_ini = -0.000003011 V, v_off_fin = -0.000002101 V 12:20:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000011717 Vs 12:20:36 Voltage Offset Correction: v_off_ini = -0.000002908 V, v_off_fin = -0.000002908 V 12:20:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000009518 Vs 12:20:45 Voltage Offset Correction: v_off_ini = -0.000002664 V, v_off_fin = -0.000002211 V 12:20:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000010098 Vs 12:20:54 Voltage Offset Correction: v_off_ini = -0.000002755 V, v_off_fin = -0.000002420 V 12:20:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000008821 Vs 12:21:02 Voltage Offset Correction: v_off_ini = -0.000002370 V, v_off_fin = -0.000002811 V 12:21:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000010711 Vs 12:21:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000010364 +- 0.000000604 Vs 12:21:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000010364 +- 0.000000604 Vs BL = -0.00010364 +- 0.00000604 Tm 12:21:07 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00010 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00010 0.00001 -0.00010 0.00000 12:21:07 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00010 0.00001 SL = -0.0001036 +- 0.0000060 Tm^2/m^n 12:21:07 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0001036 +- 0.0000060 Tm^2/m^n 12:21:08 Magnet Current, Imag = 159.7930 A Vtrans = 1.597930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:21:09 Magnet Current, Imag = 159.7915 A Vtrans = 1.597915 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:21:11 Magnet Current, Imag = 159.8024 A Vtrans = 1.598024 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:21:12 Magnet Current, Imag = 159.8014 A Vtrans = 1.598014 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:21:12 Magnet Current Measurement: Imag = 159.7971 +- 0.0049 A 12:21:12 Magnet current ramping to 150.0000 A... 12:21:46 Magnet Current, Imag = 149.9238 A Vtrans = 1.499238 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:21:48 Magnet Current, Imag = 149.9255 A Vtrans = 1.499255 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:21:49 Magnet Current, Imag = 149.9287 A Vtrans = 1.499287 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:21:50 Magnet Current, Imag = 149.9290 A Vtrans = 1.499290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:21:50 Magnet Current Measurement: Imag = 149.9267 +- 0.0022 A 12:21:50 Magnetic Field Measurement Measuring the magnet strength... 12:21:50 Integrated Voltage Measurement... 12:22:03 Voltage Offset Correction: v_off_ini = -0.000002035 V, v_off_fin = -0.000002171 V 12:22:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000010911 Vs 12:22:12 Voltage Offset Correction: v_off_ini = -0.000001765 V, v_off_fin = -0.000002253 V 12:22:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000013335 Vs 12:22:20 Voltage Offset Correction: v_off_ini = -0.000001802 V, v_off_fin = -0.000000398 V 12:22:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000012527 Vs 12:22:29 Voltage Offset Correction: v_off_ini = -0.000001484 V, v_off_fin = -0.000000843 V 12:22:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000013317 Vs 12:22:38 Voltage Offset Correction: v_off_ini = -0.000001360 V, v_off_fin = -0.000001652 V 12:22:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000012479 Vs 12:22:46 Voltage Offset Correction: v_off_ini = -0.000001271 V, v_off_fin = -0.000001426 V 12:22:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000011066 Vs 12:22:55 Voltage Offset Correction: v_off_ini = -0.000001525 V, v_off_fin = -0.000001023 V 12:22:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000014210 Vs 12:23:03 Voltage Offset Correction: v_off_ini = -0.000001210 V, v_off_fin = -0.000001038 V 12:23:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000012826 Vs 12:23:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000012584 +- 0.000000682 Vs 12:23:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000012584 +- 0.000000682 Vs BL = -0.00012584 +- 0.00000682 Tm 12:23:08 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00013 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00013 0.00001 -0.00013 0.00000 12:23:08 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00013 0.00001 SL = -0.0001258 +- 0.0000068 Tm^2/m^n 12:23:08 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0001258 +- 0.0000068 Tm^2/m^n 12:23:10 Magnet Current, Imag = 149.9350 A Vtrans = 1.499350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:23:11 Magnet Current, Imag = 149.9130 A Vtrans = 1.499130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:23:12 Magnet Current, Imag = 149.9302 A Vtrans = 1.499302 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:23:13 Magnet Current, Imag = 149.9301 A Vtrans = 1.499301 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:23:13 Magnet Current Measurement: Imag = 149.9271 +- 0.0084 A 12:23:13 Magnet current ramping to 140.0000 A... 12:23:48 Magnet Current, Imag = 139.8643 A Vtrans = 1.398643 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:23:49 Magnet Current, Imag = 139.8465 A Vtrans = 1.398465 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:23:50 Magnet Current, Imag = 139.8623 A Vtrans = 1.398623 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:23:51 Magnet Current, Imag = 139.8523 A Vtrans = 1.398523 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:23:51 Magnet Current Measurement: Imag = 139.8563 +- 0.0073 A 12:23:51 Magnetic Field Measurement Measuring the magnet strength... 12:23:51 Integrated Voltage Measurement... 12:24:05 Voltage Offset Correction: v_off_ini = 0.000000310 V, v_off_fin = 0.000000413 V 12:24:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000013562 Vs 12:24:13 Voltage Offset Correction: v_off_ini = 0.000000545 V, v_off_fin = 0.000002011 V 12:24:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000013030 Vs 12:24:22 Voltage Offset Correction: v_off_ini = 0.000000093 V, v_off_fin = 0.000000546 V 12:24:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000012896 Vs 12:24:30 Voltage Offset Correction: v_off_ini = 0.000000374 V, v_off_fin = 0.000000535 V 12:24:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000013322 Vs 12:24:39 Voltage Offset Correction: v_off_ini = 0.000000362 V, v_off_fin = 0.000000576 V 12:24:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000013114 Vs 12:24:48 Voltage Offset Correction: v_off_ini = 0.000000262 V, v_off_fin = -0.000000121 V 12:24:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000013807 Vs 12:24:56 Voltage Offset Correction: v_off_ini = 0.000000115 V, v_off_fin = 0.000000041 V 12:24:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000013854 Vs 12:25:05 Voltage Offset Correction: v_off_ini = -0.000000099 V, v_off_fin = -0.000000971 V 12:25:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000011895 Vs 12:25:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000013185 +- 0.000000218 Vs 12:25:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000013185 +- 0.000000218 Vs BL = -0.00013185 +- 0.00000218 Tm 12:25:10 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00013 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00013 0.00000 -0.00013 0.00000 12:25:10 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00013 0.00000 SL = -0.0001318 +- 0.0000022 Tm^2/m^n 12:25:10 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0001318 +- 0.0000022 Tm^2/m^n 12:25:11 Magnet Current, Imag = 139.8549 A Vtrans = 1.398549 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:12 Magnet Current, Imag = 139.8682 A Vtrans = 1.398682 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:13 Magnet Current, Imag = 139.8538 A Vtrans = 1.398538 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:14 Magnet Current, Imag = 139.8527 A Vtrans = 1.398527 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:14 Magnet Current Measurement: Imag = 139.8574 +- 0.0063 A 12:25:15 Magnet current ramping to 130.0000 A... 12:25:49 Magnet Current, Imag = 129.9025 A Vtrans = 1.299025 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:50 Magnet Current, Imag = 129.8990 A Vtrans = 1.298990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:51 Magnet Current, Imag = 129.9040 A Vtrans = 1.299040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:53 Magnet Current, Imag = 129.9006 A Vtrans = 1.299006 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:53 Magnet Current Measurement: Imag = 129.9015 +- 0.0019 A 12:25:53 Magnetic Field Measurement Measuring the magnet strength... 12:25:53 Integrated Voltage Measurement... 12:26:06 Voltage Offset Correction: v_off_ini = -0.000001018 V, v_off_fin = -0.000000551 V 12:26:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000015497 Vs 12:26:14 Voltage Offset Correction: v_off_ini = -0.000001616 V, v_off_fin = -0.000001830 V 12:26:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000015728 Vs 12:26:23 Voltage Offset Correction: v_off_ini = -0.000001960 V, v_off_fin = -0.000002162 V 12:26:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000015329 Vs 12:26:32 Voltage Offset Correction: v_off_ini = -0.000002304 V, v_off_fin = -0.000003566 V 12:26:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000017526 Vs 12:26:40 Voltage Offset Correction: v_off_ini = -0.000002173 V, v_off_fin = -0.000001893 V 12:26:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000015413 Vs 12:26:49 Voltage Offset Correction: v_off_ini = -0.000002798 V, v_off_fin = -0.000001918 V 12:26:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000014845 Vs 12:26:57 Voltage Offset Correction: v_off_ini = -0.000002731 V, v_off_fin = -0.000002519 V 12:26:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000015196 Vs 12:27:06 Voltage Offset Correction: v_off_ini = -0.000002891 V, v_off_fin = -0.000002621 V 12:27:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000015840 Vs 12:27:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000015672 +- 0.000000472 Vs 12:27:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000015672 +- 0.000000472 Vs BL = -0.00015672 +- 0.00000472 Tm 12:27:11 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00016 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00016 0.00000 -0.00016 0.00000 12:27:11 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00016 0.00000 SL = -0.0001567 +- 0.0000047 Tm^2/m^n 12:27:11 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0001567 +- 0.0000047 Tm^2/m^n 12:27:12 Magnet Current, Imag = 129.9037 A Vtrans = 1.299037 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:13 Magnet Current, Imag = 129.8963 A Vtrans = 1.298963 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:14 Magnet Current, Imag = 129.9022 A Vtrans = 1.299022 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:16 Magnet Current, Imag = 129.8911 A Vtrans = 1.298911 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:16 Magnet Current Measurement: Imag = 129.8983 +- 0.0050 A 12:27:16 Magnet current ramping to 120.0000 A... 12:27:50 Magnet Current, Imag = 119.8238 A Vtrans = 1.198238 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:51 Magnet Current, Imag = 119.8282 A Vtrans = 1.198282 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:53 Magnet Current, Imag = 119.8220 A Vtrans = 1.198220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:54 Magnet Current, Imag = 119.8315 A Vtrans = 1.198315 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:54 Magnet Current Measurement: Imag = 119.8264 +- 0.0037 A 12:27:54 Magnetic Field Measurement Measuring the magnet strength... 12:27:54 Integrated Voltage Measurement... 12:28:07 Voltage Offset Correction: v_off_ini = -0.000001664 V, v_off_fin = -0.000002157 V 12:28:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000017231 Vs 12:28:16 Voltage Offset Correction: v_off_ini = -0.000001688 V, v_off_fin = -0.000001641 V 12:28:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000016256 Vs 12:28:24 Voltage Offset Correction: v_off_ini = -0.000001458 V, v_off_fin = -0.000001480 V 12:28:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000017000 Vs 12:28:33 Voltage Offset Correction: v_off_ini = -0.000001523 V, v_off_fin = -0.000001555 V 12:28:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000016668 Vs 12:28:41 Voltage Offset Correction: v_off_ini = -0.000001912 V, v_off_fin = -0.000001087 V 12:28:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000017227 Vs 12:28:50 Voltage Offset Correction: v_off_ini = -0.000001684 V, v_off_fin = -0.000001684 V 12:28:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000017187 Vs 12:28:59 Voltage Offset Correction: v_off_ini = -0.000001660 V, v_off_fin = -0.000000634 V 12:28:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000018344 Vs 12:29:07 Voltage Offset Correction: v_off_ini = -0.000001247 V, v_off_fin = -0.000001211 V 12:29:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000017235 Vs 12:29:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000017143 +- 0.000000411 Vs 12:29:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000017143 +- 0.000000411 Vs BL = -0.00017143 +- 0.00000411 Tm 12:29:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00017 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00017 0.00000 -0.00017 0.00000 12:29:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00017 0.00000 SL = -0.0001714 +- 0.0000041 Tm^2/m^n 12:29:12 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0001714 +- 0.0000041 Tm^2/m^n 12:29:13 Magnet Current, Imag = 119.8281 A Vtrans = 1.198281 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:14 Magnet Current, Imag = 119.8225 A Vtrans = 1.198225 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:16 Magnet Current, Imag = 119.8315 A Vtrans = 1.198315 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:17 Magnet Current, Imag = 119.8162 A Vtrans = 1.198162 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:17 Magnet Current Measurement: Imag = 119.8246 +- 0.0058 A 12:29:17 Magnet current ramping to 110.0000 A... 12:29:51 Magnet Current, Imag = 109.9361 A Vtrans = 1.099361 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:53 Magnet Current, Imag = 109.9272 A Vtrans = 1.099272 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:54 Magnet Current, Imag = 109.9247 A Vtrans = 1.099247 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:55 Magnet Current, Imag = 109.9358 A Vtrans = 1.099358 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:55 Magnet Current Measurement: Imag = 109.9309 +- 0.0051 A 12:29:55 Magnetic Field Measurement Measuring the magnet strength... 12:29:55 Integrated Voltage Measurement... 12:30:08 Voltage Offset Correction: v_off_ini = -0.000000739 V, v_off_fin = 0.000001401 V 12:30:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000019758 Vs 12:30:17 Voltage Offset Correction: v_off_ini = -0.000000622 V, v_off_fin = -0.000001028 V 12:30:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000019194 Vs 12:30:25 Voltage Offset Correction: v_off_ini = -0.000001567 V, v_off_fin = -0.000000831 V 12:30:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000015941 Vs 12:30:34 Voltage Offset Correction: v_off_ini = -0.000000460 V, v_off_fin = -0.000001258 V 12:30:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000018680 Vs 12:30:43 Voltage Offset Correction: v_off_ini = -0.000000903 V, v_off_fin = 0.000000118 V 12:30:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000016126 Vs 12:30:51 Voltage Offset Correction: v_off_ini = -0.000000810 V, v_off_fin = -0.000000397 V 12:30:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000016296 Vs 12:31:00 Voltage Offset Correction: v_off_ini = -0.000001158 V, v_off_fin = -0.000001023 V 12:31:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000017233 Vs 12:31:08 Voltage Offset Correction: v_off_ini = -0.000000858 V, v_off_fin = -0.000001299 V 12:31:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000016414 Vs 12:31:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000017455 +- 0.000001230 Vs 12:31:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000017455 +- 0.000001230 Vs BL = -0.00017455 +- 0.00001230 Tm 12:31:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00017 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00017 0.00001 -0.00017 0.00000 12:31:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00017 0.00001 SL = -0.0001746 +- 0.0000123 Tm^2/m^n 12:31:13 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0001746 +- 0.0000123 Tm^2/m^n 12:31:15 Magnet Current, Imag = 109.9217 A Vtrans = 1.099217 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:16 Magnet Current, Imag = 109.9326 A Vtrans = 1.099326 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:17 Magnet Current, Imag = 109.9215 A Vtrans = 1.099215 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:18 Magnet Current, Imag = 109.9300 A Vtrans = 1.099300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:18 Magnet Current Measurement: Imag = 109.9265 +- 0.0049 A 12:31:18 Magnet current ramping to 100.0000 A... 12:31:53 Magnet Current, Imag = 99.8685 A Vtrans = 0.998685 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:54 Magnet Current, Imag = 99.8633 A Vtrans = 0.998633 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:55 Magnet Current, Imag = 99.8750 A Vtrans = 0.998750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:56 Magnet Current, Imag = 99.8647 A Vtrans = 0.998647 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:56 Magnet Current Measurement: Imag = 99.8679 +- 0.0045 A 12:31:56 Magnetic Field Measurement Measuring the magnet strength... 12:31:56 Integrated Voltage Measurement... 12:32:10 Voltage Offset Correction: v_off_ini = -0.000002170 V, v_off_fin = -0.000001906 V 12:32:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000019983 Vs 12:32:18 Voltage Offset Correction: v_off_ini = -0.000001609 V, v_off_fin = -0.000001488 V 12:32:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000019432 Vs 12:32:27 Voltage Offset Correction: v_off_ini = -0.000000806 V, v_off_fin = -0.000000787 V 12:32:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000018113 Vs 12:32:35 Voltage Offset Correction: v_off_ini = -0.000001005 V, v_off_fin = -0.000000313 V 12:32:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000019410 Vs 12:32:44 Voltage Offset Correction: v_off_ini = -0.000000964 V, v_off_fin = -0.000001654 V 12:32:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000017831 Vs 12:32:53 Voltage Offset Correction: v_off_ini = -0.000000917 V, v_off_fin = -0.000000179 V 12:32:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000020666 Vs 12:33:01 Voltage Offset Correction: v_off_ini = -0.000000668 V, v_off_fin = -0.000001177 V 12:33:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000017694 Vs 12:33:10 Voltage Offset Correction: v_off_ini = -0.000000768 V, v_off_fin = -0.000001407 V 12:33:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000020223 Vs 12:33:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000019169 +- 0.000000356 Vs 12:33:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000019169 +- 0.000000356 Vs BL = -0.00019169 +- 0.00000356 Tm 12:33:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00019 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00019 0.00000 -0.00019 0.00000 12:33:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00019 0.00000 SL = -0.0001917 +- 0.0000036 Tm^2/m^n 12:33:15 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0001917 +- 0.0000036 Tm^2/m^n 12:33:16 Magnet Current, Imag = 99.8711 A Vtrans = 0.998711 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:17 Magnet Current, Imag = 99.8744 A Vtrans = 0.998744 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:18 Magnet Current, Imag = 99.8733 A Vtrans = 0.998733 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:19 Magnet Current, Imag = 99.8774 A Vtrans = 0.998774 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:19 Magnet Current Measurement: Imag = 99.8740 +- 0.0023 A 12:33:19 Magnet current ramping to 90.0000 A... 12:33:54 Magnet Current, Imag = 89.9173 A Vtrans = 0.899173 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:55 Magnet Current, Imag = 89.9041 A Vtrans = 0.899041 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:56 Magnet Current, Imag = 89.9089 A Vtrans = 0.899089 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:58 Magnet Current, Imag = 89.9025 A Vtrans = 0.899025 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:58 Magnet Current Measurement: Imag = 89.9082 +- 0.0058 A 12:33:58 Magnetic Field Measurement Measuring the magnet strength... 12:33:58 Integrated Voltage Measurement... 12:34:11 Voltage Offset Correction: v_off_ini = 0.000001189 V, v_off_fin = 0.000000986 V 12:34:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000017812 Vs 12:34:19 Voltage Offset Correction: v_off_ini = 0.000001143 V, v_off_fin = 0.000001232 V 12:34:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000022760 Vs 12:34:28 Voltage Offset Correction: v_off_ini = 0.000001336 V, v_off_fin = 0.000001186 V 12:34:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000016596 Vs 12:34:37 Voltage Offset Correction: v_off_ini = 0.000001696 V, v_off_fin = 0.000002253 V 12:34:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000019829 Vs 12:34:45 Voltage Offset Correction: v_off_ini = 0.000001596 V, v_off_fin = 0.000002251 V 12:34:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000017521 Vs 12:34:54 Voltage Offset Correction: v_off_ini = 0.000001234 V, v_off_fin = 0.000002381 V 12:34:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000017944 Vs 12:35:02 Voltage Offset Correction: v_off_ini = 0.000001641 V, v_off_fin = 0.000001775 V 12:35:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000018196 Vs 12:35:11 Voltage Offset Correction: v_off_ini = 0.000000690 V, v_off_fin = 0.000002077 V 12:35:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000021952 Vs 12:35:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000019076 +- 0.000001119 Vs 12:35:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000019076 +- 0.000001119 Vs BL = -0.00019076 +- 0.00001119 Tm 12:35:16 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00019 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00019 0.00001 -0.00019 0.00000 12:35:16 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00019 0.00001 SL = -0.0001908 +- 0.0000112 Tm^2/m^n 12:35:16 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0001908 +- 0.0000112 Tm^2/m^n 12:35:17 Magnet Current, Imag = 89.9080 A Vtrans = 0.899080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:18 Magnet Current, Imag = 89.9040 A Vtrans = 0.899040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:19 Magnet Current, Imag = 89.9119 A Vtrans = 0.899119 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:20 Magnet Current, Imag = 89.9015 A Vtrans = 0.899015 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:21 Magnet Current Measurement: Imag = 89.9064 +- 0.0040 A 12:35:21 Magnet current ramping to 80.0000 A... 12:35:55 Magnet Current, Imag = 79.8380 A Vtrans = 0.798380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:56 Magnet Current, Imag = 79.8385 A Vtrans = 0.798385 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:57 Magnet Current, Imag = 79.8315 A Vtrans = 0.798315 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:59 Magnet Current, Imag = 79.8464 A Vtrans = 0.798464 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:59 Magnet Current Measurement: Imag = 79.8386 +- 0.0053 A 12:35:59 Magnetic Field Measurement Measuring the magnet strength... 12:35:59 Integrated Voltage Measurement... 12:36:12 Voltage Offset Correction: v_off_ini = -0.000002111 V, v_off_fin = -0.000002177 V 12:36:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000020096 Vs 12:36:20 Voltage Offset Correction: v_off_ini = -0.000002305 V, v_off_fin = -0.000003124 V 12:36:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000019272 Vs 12:36:29 Voltage Offset Correction: v_off_ini = -0.000002688 V, v_off_fin = -0.000003534 V 12:36:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000020650 Vs 12:36:38 Voltage Offset Correction: v_off_ini = -0.000002822 V, v_off_fin = -0.000002617 V 12:36:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000021618 Vs 12:36:46 Voltage Offset Correction: v_off_ini = -0.000003506 V, v_off_fin = -0.000003686 V 12:36:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000018678 Vs 12:36:55 Voltage Offset Correction: v_off_ini = -0.000003197 V, v_off_fin = -0.000002205 V 12:36:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000021751 Vs 12:37:04 Voltage Offset Correction: v_off_ini = -0.000003035 V, v_off_fin = -0.000002255 V 12:37:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000020623 Vs 12:37:12 Voltage Offset Correction: v_off_ini = -0.000002886 V, v_off_fin = -0.000001906 V 12:37:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000021622 Vs 12:37:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000020539 +- 0.000000619 Vs 12:37:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000020539 +- 0.000000619 Vs BL = -0.00020539 +- 0.00000619 Tm 12:37:17 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00021 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00021 0.00001 -0.00021 0.00000 12:37:17 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00021 0.00001 SL = -0.0002054 +- 0.0000062 Tm^2/m^n 12:37:17 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0002054 +- 0.0000062 Tm^2/m^n 12:37:18 Magnet Current, Imag = 79.8458 A Vtrans = 0.798458 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:37:19 Magnet Current, Imag = 79.8407 A Vtrans = 0.798407 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:37:20 Magnet Current, Imag = 79.8370 A Vtrans = 0.798370 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:37:22 Magnet Current, Imag = 79.8419 A Vtrans = 0.798419 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:37:22 Magnet Current Measurement: Imag = 79.8414 +- 0.0031 A 12:37:22 Magnet current ramping to 70.0000 A... 12:37:56 Magnet Current, Imag = 70.0293 A Vtrans = 0.700293 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:37:58 Magnet Current, Imag = 70.0441 A Vtrans = 0.700441 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:37:59 Magnet Current, Imag = 70.0344 A Vtrans = 0.700344 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:38:00 Magnet Current, Imag = 70.0324 A Vtrans = 0.700324 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:38:00 Magnet Current Measurement: Imag = 70.0350 +- 0.0055 A 12:38:00 Magnetic Field Measurement Measuring the magnet strength... 12:38:00 Integrated Voltage Measurement... 12:38:13 Voltage Offset Correction: v_off_ini = -0.000000811 V, v_off_fin = -0.000000777 V 12:38:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000020812 Vs 12:38:22 Voltage Offset Correction: v_off_ini = -0.000000352 V, v_off_fin = 0.000000349 V 12:38:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000022915 Vs 12:38:30 Voltage Offset Correction: v_off_ini = -0.000000243 V, v_off_fin = -0.000000868 V 12:38:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000020481 Vs 12:38:39 Voltage Offset Correction: v_off_ini = 0.000000156 V, v_off_fin = 0.000001762 V 12:38:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000017314 Vs 12:38:47 Voltage Offset Correction: v_off_ini = 0.000001085 V, v_off_fin = 0.000000682 V 12:38:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000019912 Vs 12:38:56 Voltage Offset Correction: v_off_ini = 0.000000877 V, v_off_fin = 0.000000713 V 12:38:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000019328 Vs 12:39:05 Voltage Offset Correction: v_off_ini = 0.000000765 V, v_off_fin = 0.000002553 V 12:39:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000019928 Vs 12:39:13 Voltage Offset Correction: v_off_ini = 0.000000994 V, v_off_fin = 0.000001238 V 12:39:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000021473 Vs 12:39:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000020270 +- 0.000001122 Vs 12:39:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000020270 +- 0.000001122 Vs BL = -0.00020270 +- 0.00001122 Tm 12:39:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00020 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00020 0.00001 -0.00020 0.00000 12:39:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00020 0.00001 SL = -0.0002027 +- 0.0000112 Tm^2/m^n 12:39:18 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0002027 +- 0.0000112 Tm^2/m^n 12:39:19 Magnet Current, Imag = 70.0403 A Vtrans = 0.700403 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:39:20 Magnet Current, Imag = 70.0291 A Vtrans = 0.700291 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:39:22 Magnet Current, Imag = 70.0375 A Vtrans = 0.700375 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:39:23 Magnet Current, Imag = 70.0252 A Vtrans = 0.700252 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:39:23 Magnet Current Measurement: Imag = 70.0330 +- 0.0061 A 12:39:23 Magnet current ramping to 60.0000 A... 12:39:57 Magnet Current, Imag = 59.9737 A Vtrans = 0.599737 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:39:59 Magnet Current, Imag = 59.9681 A Vtrans = 0.599681 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:40:00 Magnet Current, Imag = 59.9657 A Vtrans = 0.599657 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:40:01 Magnet Current, Imag = 59.9733 A Vtrans = 0.599733 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:40:01 Magnet Current Measurement: Imag = 59.9702 +- 0.0034 A 12:40:01 Magnetic Field Measurement Measuring the magnet strength... 12:40:01 Integrated Voltage Measurement... 12:40:14 Voltage Offset Correction: v_off_ini = 0.000001144 V, v_off_fin = 0.000001840 V 12:40:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000022184 Vs 12:40:23 Voltage Offset Correction: v_off_ini = 0.000001087 V, v_off_fin = 0.000001519 V 12:40:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000019871 Vs 12:40:31 Voltage Offset Correction: v_off_ini = 0.000001650 V, v_off_fin = 0.000001425 V 12:40:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000021197 Vs 12:40:40 Voltage Offset Correction: v_off_ini = 0.000001994 V, v_off_fin = 0.000002958 V 12:40:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000021497 Vs 12:40:49 Voltage Offset Correction: v_off_ini = 0.000002213 V, v_off_fin = 0.000003253 V 12:40:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000019737 Vs 12:40:57 Voltage Offset Correction: v_off_ini = 0.000001778 V, v_off_fin = 0.000001495 V 12:40:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000022703 Vs 12:41:06 Voltage Offset Correction: v_off_ini = 0.000001498 V, v_off_fin = 0.000000641 V 12:41:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000023001 Vs 12:41:14 Voltage Offset Correction: v_off_ini = 0.000000995 V, v_off_fin = 0.000000484 V 12:41:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000020005 Vs 12:41:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000021274 +- 0.000000174 Vs 12:41:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000021274 +- 0.000000174 Vs BL = -0.00021274 +- 0.00000174 Tm 12:41:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00021 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00021 0.00000 -0.00021 0.00000 12:41:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00021 0.00000 SL = -0.0002127 +- 0.0000017 Tm^2/m^n 12:41:19 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0002127 +- 0.0000017 Tm^2/m^n 12:41:20 Magnet Current, Imag = 59.9774 A Vtrans = 0.599774 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:41:22 Magnet Current, Imag = 59.9771 A Vtrans = 0.599771 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:41:23 Magnet Current, Imag = 59.9728 A Vtrans = 0.599728 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:41:24 Magnet Current, Imag = 59.9639 A Vtrans = 0.599639 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:41:24 Magnet Current Measurement: Imag = 59.9728 +- 0.0055 A 12:41:24 Magnet current ramping to 50.0000 A... 12:41:59 Magnet Current, Imag = 50.0061 A Vtrans = 0.500061 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:42:00 Magnet Current, Imag = 50.0121 A Vtrans = 0.500121 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:42:01 Magnet Current, Imag = 50.0167 A Vtrans = 0.500167 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:42:02 Magnet Current, Imag = 50.0051 A Vtrans = 0.500051 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:42:02 Magnet Current Measurement: Imag = 50.0100 +- 0.0047 A 12:42:02 Magnetic Field Measurement Measuring the magnet strength... 12:42:02 Integrated Voltage Measurement... 12:42:15 Voltage Offset Correction: v_off_ini = 0.000001176 V, v_off_fin = 0.000002609 V 12:42:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000022197 Vs 12:42:24 Voltage Offset Correction: v_off_ini = 0.000001193 V, v_off_fin = 0.000000744 V 12:42:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000022068 Vs 12:42:33 Voltage Offset Correction: v_off_ini = 0.000000905 V, v_off_fin = 0.000000253 V 12:42:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000022410 Vs 12:42:41 Voltage Offset Correction: v_off_ini = 0.000000611 V, v_off_fin = -0.000000159 V 12:42:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000020837 Vs 12:42:50 Voltage Offset Correction: v_off_ini = -0.000000535 V, v_off_fin = -0.000000346 V 12:42:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000022108 Vs 12:42:58 Voltage Offset Correction: v_off_ini = -0.000001238 V, v_off_fin = -0.000002328 V 12:42:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000022583 Vs 12:43:07 Voltage Offset Correction: v_off_ini = -0.000001016 V, v_off_fin = -0.000000899 V 12:43:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000021814 Vs 12:43:16 Voltage Offset Correction: v_off_ini = -0.000001628 V, v_off_fin = -0.000000832 V 12:43:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000021871 Vs 12:43:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000021986 +- 0.000000275 Vs 12:43:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000021986 +- 0.000000275 Vs BL = -0.00021986 +- 0.00000275 Tm 12:43:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00022 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00022 0.00000 -0.00022 0.00000 12:43:20 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00022 0.00000 SL = -0.0002199 +- 0.0000027 Tm^2/m^n 12:43:20 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0002199 +- 0.0000027 Tm^2/m^n 12:43:22 Magnet Current, Imag = 50.0160 A Vtrans = 0.500160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:43:23 Magnet Current, Imag = 50.0094 A Vtrans = 0.500094 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:43:24 Magnet Current, Imag = 50.0008 A Vtrans = 0.500008 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:43:25 Magnet Current, Imag = 50.0126 A Vtrans = 0.500126 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:43:25 Magnet Current Measurement: Imag = 50.0097 +- 0.0056 A 12:43:25 Magnet current ramping to 40.0000 A... 12:44:00 Magnet Current, Imag = 39.9529 A Vtrans = 0.399529 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:44:01 Magnet Current, Imag = 39.9349 A Vtrans = 0.399349 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:44:02 Magnet Current, Imag = 39.9527 A Vtrans = 0.399527 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:44:03 Magnet Current, Imag = 39.9338 A Vtrans = 0.399338 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:44:03 Magnet Current Measurement: Imag = 39.9436 +- 0.0092 A 12:44:04 Magnetic Field Measurement Measuring the magnet strength... 12:44:04 Integrated Voltage Measurement... 12:44:17 Voltage Offset Correction: v_off_ini = -0.000001966 V, v_off_fin = -0.000003818 V 12:44:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000023294 Vs 12:44:25 Voltage Offset Correction: v_off_ini = -0.000001929 V, v_off_fin = -0.000000683 V 12:44:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000022805 Vs 12:44:34 Voltage Offset Correction: v_off_ini = -0.000001842 V, v_off_fin = -0.000001408 V 12:44:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000020233 Vs 12:44:42 Voltage Offset Correction: v_off_ini = -0.000001456 V, v_off_fin = -0.000000289 V 12:44:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000022898 Vs 12:44:51 Voltage Offset Correction: v_off_ini = -0.000001381 V, v_off_fin = -0.000001705 V 12:44:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000023364 Vs 12:45:00 Voltage Offset Correction: v_off_ini = -0.000000991 V, v_off_fin = 0.000000360 V 12:45:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000024183 Vs 12:45:08 Voltage Offset Correction: v_off_ini = -0.000000756 V, v_off_fin = -0.000001113 V 12:45:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000021645 Vs 12:45:17 Voltage Offset Correction: v_off_ini = -0.000000449 V, v_off_fin = 0.000000929 V 12:45:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000020936 Vs 12:45:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000022420 +- 0.000001029 Vs 12:45:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000022420 +- 0.000001029 Vs BL = -0.00022420 +- 0.00001029 Tm 12:45:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00022 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00022 0.00001 -0.00022 0.00000 12:45:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00022 0.00001 SL = -0.0002242 +- 0.0000103 Tm^2/m^n 12:45:22 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0002242 +- 0.0000103 Tm^2/m^n 12:45:23 Magnet Current, Imag = 39.9459 A Vtrans = 0.399459 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:45:24 Magnet Current, Imag = 39.9457 A Vtrans = 0.399457 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:45:25 Magnet Current, Imag = 39.9382 A Vtrans = 0.399382 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:45:26 Magnet Current, Imag = 39.9344 A Vtrans = 0.399344 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:45:26 Magnet Current Measurement: Imag = 39.9411 +- 0.0049 A 12:45:27 Magnet current ramping to 30.0000 A... 12:46:01 Magnet Current, Imag = 30.0706 A Vtrans = 0.300706 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:46:02 Magnet Current, Imag = 30.0755 A Vtrans = 0.300755 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:46:03 Magnet Current, Imag = 30.0797 A Vtrans = 0.300797 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:46:05 Magnet Current, Imag = 30.0672 A Vtrans = 0.300672 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:46:05 Magnet Current Measurement: Imag = 30.0733 +- 0.0048 A 12:46:05 Magnetic Field Measurement Measuring the magnet strength... 12:46:05 Integrated Voltage Measurement... 12:46:18 Voltage Offset Correction: v_off_ini = -0.000000605 V, v_off_fin = -0.000000798 V 12:46:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000021593 Vs 12:46:26 Voltage Offset Correction: v_off_ini = -0.000000208 V, v_off_fin = -0.000000751 V 12:46:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000023902 Vs 12:46:35 Voltage Offset Correction: v_off_ini = -0.000000119 V, v_off_fin = 0.000001881 V 12:46:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000019461 Vs 12:46:44 Voltage Offset Correction: v_off_ini = -0.000000421 V, v_off_fin = -0.000000278 V 12:46:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000022566 Vs 12:46:52 Voltage Offset Correction: v_off_ini = -0.000000501 V, v_off_fin = -0.000000114 V 12:46:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000022819 Vs 12:47:01 Voltage Offset Correction: v_off_ini = -0.000000239 V, v_off_fin = -0.000000606 V 12:47:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000023712 Vs 12:47:09 Voltage Offset Correction: v_off_ini = 0.000000177 V, v_off_fin = -0.000000039 V 12:47:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000022171 Vs 12:47:18 Voltage Offset Correction: v_off_ini = -0.000000348 V, v_off_fin = 0.000001214 V 12:47:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000023185 Vs 12:47:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000022426 +- 0.000000847 Vs 12:47:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000022426 +- 0.000000847 Vs BL = -0.00022426 +- 0.00000847 Tm 12:47:23 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00022 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00022 0.00001 -0.00022 0.00000 12:47:23 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00022 0.00001 SL = -0.0002243 +- 0.0000085 Tm^2/m^n 12:47:23 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0002243 +- 0.0000085 Tm^2/m^n 12:47:24 Magnet Current, Imag = 30.0633 A Vtrans = 0.300633 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:47:25 Magnet Current, Imag = 30.0823 A Vtrans = 0.300823 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:47:27 Magnet Current, Imag = 30.0698 A Vtrans = 0.300698 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:47:28 Magnet Current, Imag = 30.0748 A Vtrans = 0.300748 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:47:28 Magnet Current Measurement: Imag = 30.0725 +- 0.0070 A 12:47:28 Magnet current ramping to 20.0000 A... 12:48:03 Magnet Current, Imag = 20.0153 A Vtrans = 0.200153 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:48:05 Magnet Current, Imag = 20.0222 A Vtrans = 0.200222 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:48:06 Magnet Current, Imag = 20.0232 A Vtrans = 0.200232 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:48:08 Magnet Current, Imag = 20.0218 A Vtrans = 0.200218 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:48:08 Magnet Current Measurement: Imag = 20.0206 +- 0.0031 A 12:48:08 Magnetic Field Measurement Measuring the magnet strength... 12:48:08 Integrated Voltage Measurement... 12:48:21 Voltage Offset Correction: v_off_ini = -0.000001839 V, v_off_fin = -0.000000406 V 12:48:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000021642 Vs 12:48:30 Voltage Offset Correction: v_off_ini = -0.000001998 V, v_off_fin = -0.000002751 V 12:48:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000021243 Vs 12:48:38 Voltage Offset Correction: v_off_ini = -0.000002439 V, v_off_fin = -0.000003358 V 12:48:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000022160 Vs 12:48:47 Voltage Offset Correction: v_off_ini = -0.000003319 V, v_off_fin = -0.000003615 V 12:48:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000022259 Vs 12:48:56 Voltage Offset Correction: v_off_ini = -0.000003609 V, v_off_fin = -0.000003676 V 12:48:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000024532 Vs 12:49:04 Voltage Offset Correction: v_off_ini = -0.000003952 V, v_off_fin = -0.000003693 V 12:49:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000024358 Vs 12:49:13 Voltage Offset Correction: v_off_ini = -0.000003334 V, v_off_fin = -0.000003257 V 12:49:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000023951 Vs 12:49:22 Voltage Offset Correction: v_off_ini = -0.000002820 V, v_off_fin = -0.000002934 V 12:49:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000024137 Vs 12:49:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000023035 +- 0.000001247 Vs 12:49:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000023035 +- 0.000001247 Vs BL = -0.00023035 +- 0.00001247 Tm 12:49:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00023 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00023 0.00001 -0.00023 0.00000 12:49:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00023 0.00001 SL = -0.0002304 +- 0.0000125 Tm^2/m^n 12:49:26 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0002304 +- 0.0000125 Tm^2/m^n 12:49:28 Magnet Current, Imag = 20.0255 A Vtrans = 0.200255 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:49:30 Magnet Current, Imag = 20.0226 A Vtrans = 0.200226 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:49:31 Magnet Current, Imag = 20.0182 A Vtrans = 0.200182 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:49:33 Magnet Current, Imag = 20.0255 A Vtrans = 0.200255 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:49:33 Magnet Current Measurement: Imag = 20.0229 +- 0.0030 A 12:49:33 Magnet current ramping to 10.0000 A... 12:50:09 Magnet Current, Imag = 10.0493 A Vtrans = 0.100493 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:50:10 Magnet Current, Imag = 10.0475 A Vtrans = 0.100475 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:50:12 Magnet Current, Imag = 10.0511 A Vtrans = 0.100511 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:50:14 Magnet Current, Imag = 10.0587 A Vtrans = 0.100587 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:50:14 Magnet Current Measurement: Imag = 10.0516 +- 0.0043 A 12:50:14 Magnetic Field Measurement Measuring the magnet strength... 12:50:14 Integrated Voltage Measurement... 12:50:27 Voltage Offset Correction: v_off_ini = -0.000001312 V, v_off_fin = -0.000000993 V 12:50:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000021790 Vs 12:50:36 Voltage Offset Correction: v_off_ini = -0.000001543 V, v_off_fin = -0.000003112 V 12:50:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000026527 Vs 12:50:44 Voltage Offset Correction: v_off_ini = -0.000001011 V, v_off_fin = -0.000001711 V 12:50:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000024742 Vs 12:50:53 Voltage Offset Correction: v_off_ini = -0.000001227 V, v_off_fin = 0.000000308 V 12:50:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000022372 Vs 12:51:02 Voltage Offset Correction: v_off_ini = -0.000001844 V, v_off_fin = -0.000001699 V 12:51:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000022565 Vs 12:51:10 Voltage Offset Correction: v_off_ini = -0.000001556 V, v_off_fin = -0.000000496 V 12:51:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000025150 Vs 12:51:19 Voltage Offset Correction: v_off_ini = -0.000000872 V, v_off_fin = -0.000000825 V 12:51:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000023125 Vs 12:51:27 Voltage Offset Correction: v_off_ini = -0.000001311 V, v_off_fin = -0.000000999 V 12:51:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000021276 Vs 12:51:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000023443 +- 0.000000749 Vs 12:51:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000023443 +- 0.000000749 Vs BL = -0.00023443 +- 0.00000749 Tm 12:51:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00023 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00023 0.00001 -0.00023 0.00000 12:51:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00023 0.00001 SL = -0.0002344 +- 0.0000075 Tm^2/m^n 12:51:32 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0002344 +- 0.0000075 Tm^2/m^n 12:51:34 Magnet Current, Imag = 10.0592 A Vtrans = 0.100592 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:51:36 Magnet Current, Imag = 10.0542 A Vtrans = 0.100542 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:51:37 Magnet Current, Imag = 10.0435 A Vtrans = 0.100435 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:51:39 Magnet Current, Imag = 10.0521 A Vtrans = 0.100521 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:51:39 Magnet Current Measurement: Imag = 10.0523 +- 0.0056 A 12:51:39 Magnet current ramping to 0.0000 A... 12:52:15 Magnet Current, Imag = 0.0058 A Vtrans = 0.000058 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:52:16 Magnet Current, Imag = 0.0057 A Vtrans = 0.000057 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:52:18 Magnet Current, Imag = 0.0057 A Vtrans = 0.000057 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:52:20 Magnet Current, Imag = 0.0056 A Vtrans = 0.000056 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:52:20 Magnet Current Measurement: Imag = 0.0057 +- 0.0001 A 12:52:20 Magnetic Field Measurement Measuring the magnet strength... 12:52:20 Integrated Voltage Measurement... 12:52:33 Voltage Offset Correction: v_off_ini = -0.000000197 V, v_off_fin = -0.000000313 V 12:52:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000024337 Vs 12:52:42 Voltage Offset Correction: v_off_ini = -0.000000074 V, v_off_fin = 0.000000557 V 12:52:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000022863 Vs 12:52:50 Voltage Offset Correction: v_off_ini = 0.000000270 V, v_off_fin = -0.000000067 V 12:52:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000023464 Vs 12:52:59 Voltage Offset Correction: v_off_ini = 0.000000445 V, v_off_fin = 0.000001270 V 12:52:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000027199 Vs 12:53:07 Voltage Offset Correction: v_off_ini = 0.000000380 V, v_off_fin = 0.000000746 V 12:53:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000023804 Vs 12:53:16 Voltage Offset Correction: v_off_ini = 0.000000334 V, v_off_fin = 0.000000197 V 12:53:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000023211 Vs 12:53:25 Voltage Offset Correction: v_off_ini = 0.000000729 V, v_off_fin = 0.000001101 V 12:53:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000025363 Vs 12:53:33 Voltage Offset Correction: v_off_ini = 0.000000538 V, v_off_fin = 0.000001315 V 12:53:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000025005 Vs 12:53:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000024406 +- 0.000000854 Vs 12:53:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000024406 +- 0.000000854 Vs BL = -0.00024406 +- 0.00000854 Tm 12:53:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00024 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00024 0.00001 -0.00024 0.00000 12:53:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00024 0.00001 SL = -0.0002441 +- 0.0000085 Tm^2/m^n 12:53:38 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0002441 +- 0.0000085 Tm^2/m^n 12:53:40 Magnet Current, Imag = 0.0053 A Vtrans = 0.000053 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:53:41 Magnet Current, Imag = 0.0053 A Vtrans = 0.000053 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:53:43 Magnet Current, Imag = 0.0053 A Vtrans = 0.000053 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:53:45 Magnet Current, Imag = 0.0052 A Vtrans = 0.000052 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:53:45 Magnet Current Measurement: Imag = 0.0053 +- 0.0000 A 12:53:45 Magnet current ramping to 0.0000 A...