SLAC Magnetic Measurements Date: 09-04-2002 Time: 12:08:12 Project: SPEAR3 Magnet Type: quad Magnet Name: Q9D Serial Number: Run Number: 1 Measurement Device: stretched 10 wire bundle Operator: sa Comment: Strength vs I at 7 x positions. Standardization: 3 cycles from 0.0 A to 60.0 A to 0.0 A Test Currents (A): 10.0 20.0 30.0 40.0 50.0 60.0 12:08:15 Initial Zero Current Measurement, Imag_zero = 0.0000 A 12:08:15 Magnet current ramping to 5.0000 A... 12:08:53 Magnet current ramping to 60.0000 A... 12:09:21 Magnet current ramping to 0.0000 A... 12:09:50 Magnet current ramping to 60.0000 A... 12:10:19 Magnet current ramping to 0.0000 A... 12:10:48 Magnet current ramping to 60.0000 A... 12:11:17 Magnet current ramping to 0.0000 A... 12:11:47 Magnet current ramping to 10.0000 A... 12:12:07 Magnet Current, Imag = 10.0042 A Vtrans = 0.800336 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:12:08 Magnet Current, Imag = 10.0040 A Vtrans = 0.800317 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:12:10 Magnet Current, Imag = 10.0039 A Vtrans = 0.800315 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:12:11 Magnet Current, Imag = 10.0043 A Vtrans = 0.800342 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:12:11 Magnet Current Measurement: Imag = 10.0041 +- 0.0001 A 12:12:11 Magnetic Field Measurement Measuring the magnet strength... 12:12:11 Integrated Voltage Measurement... 12:12:36 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.003399411 Vs 12:12:51 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.003382753 Vs 12:13:06 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.003401685 Vs 12:13:21 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.003381711 Vs 12:13:37 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.003401464 Vs 12:13:52 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.003383500 Vs 12:14:07 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.003397088 Vs 12:14:22 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.003378626 Vs 12:14:22 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.003390780 +- 0.000001759 Vs 12:14:22 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003390780 +- 0.000001759 Vs BL = 0.03390780 +- 0.00001759 Tm 12:14:22 Integrated Voltage Measurement... 12:14:41 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002300344 Vs 12:14:56 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.002282352 Vs 12:15:11 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002300872 Vs 12:15:26 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.002280864 Vs 12:15:41 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002300228 Vs 12:15:56 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.002283538 Vs 12:16:12 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002299742 Vs 12:16:27 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.002280470 Vs 12:16:27 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002291051 +- 0.000000653 Vs 12:16:27 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.002291051 +- 0.000000653 Vs BL = 0.02291051 +- 0.00000653 Tm 12:16:27 Integrated Voltage Measurement... 12:16:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001199740 Vs 12:17:01 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001185780 Vs 12:17:16 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001205128 Vs 12:17:31 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001186530 Vs 12:17:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001200307 Vs 12:18:01 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001178079 Vs 12:18:16 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001207726 Vs 12:18:31 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001176180 Vs 12:18:31 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001192434 +- 0.000002365 Vs 12:18:31 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.001192434 +- 0.000002365 Vs BL = 0.01192434 +- 0.00002365 Tm 12:18:32 Integrated Voltage Measurement... 12:18:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000111798 Vs 12:19:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000084258 Vs 12:19:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000111740 Vs 12:19:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000082518 Vs 12:19:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000111574 Vs 12:20:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000086751 Vs 12:20:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000112578 Vs 12:20:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000088929 Vs 12:20:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000098768 +- 0.000001354 Vs 12:20:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000098768 +- 0.000001354 Vs BL = 0.00098768 +- 0.00001354 Tm 12:20:36 Integrated Voltage Measurement... 12:20:55 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000982651 Vs 12:21:10 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001006129 Vs 12:21:25 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000984650 Vs 12:21:40 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001001474 Vs 12:21:55 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000987554 Vs 12:22:11 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001006992 Vs 12:22:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000984382 Vs 12:22:41 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001005435 Vs 12:22:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000994908 +- 0.000001522 Vs 12:22:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000994908 +- 0.000001522 Vs BL = -0.00994908 +- 0.00001522 Tm 12:22:41 Integrated Voltage Measurement... 12:23:00 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002073002 Vs 12:23:15 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002092120 Vs 12:23:30 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002078441 Vs 12:23:45 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002093296 Vs 12:24:00 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002075963 Vs 12:24:15 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002093689 Vs 12:24:30 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002070449 Vs 12:24:46 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002090175 Vs 12:24:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002083392 +- 0.000002143 Vs 12:24:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002083392 +- 0.000002143 Vs BL = -0.02083392 +- 0.00002143 Tm 12:24:46 Integrated Voltage Measurement... 12:25:04 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.003143984 Vs 12:25:20 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.003178889 Vs 12:25:35 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.003148887 Vs 12:25:50 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.003174469 Vs 12:26:05 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.003152858 Vs 12:26:20 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.003174981 Vs 12:26:35 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.003148793 Vs 12:26:50 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.003176680 Vs 12:26:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.003162443 +- 0.000000983 Vs 12:26:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003162443 +- 0.000000983 Vs BL = -0.03162443 +- 0.00000983 Tm 12:26:58 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00105 0.00001 1 -1.09271 0.00029 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.030000 0.03391 0.00002 0.03383 0.00008 -0.020000 0.02291 0.00001 0.02290 0.00001 -0.010000 0.01192 0.00002 0.01197 -0.00005 0.000000 0.00099 0.00001 0.00105 -0.00006 0.010000 -0.00995 0.00002 -0.00988 -0.00007 0.020000 -0.02083 0.00002 -0.02081 -0.00003 0.030000 -0.03162 0.00001 -0.03174 0.00011 12:26:58 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 7 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.03391 0.00002 -0.0200 0.02291 0.00001 -0.0100 0.01192 0.00002 0.0000 0.00099 0.00001 0.0100 -0.00995 0.00002 0.0200 -0.02083 0.00002 0.0300 -0.03162 0.00001 SL = -1.0927105 +- 0.0002869 Tm^2/m^n 12:26:58 Quadrupole Strength Calculation Check Slope = -1.092711 Tm/m, Inter = 0.001046 Tm, Sig_slope = 0.001462 Tm/m, Est_sig = 0.000077 Tm GL = -1.092711 +- 0.001462 T 12:26:58 Magnet Strength Measurement Harmonic Number = 2 SL = -1.0927105 +- 0.0002869 Tm^2/m^n 12:27:00 Magnet Current, Imag = 10.0028 A Vtrans = 0.800227 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:27:01 Magnet Current, Imag = 10.0033 A Vtrans = 0.800266 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:27:02 Magnet Current, Imag = 10.0027 A Vtrans = 0.800214 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:27:04 Magnet Current, Imag = 10.0030 A Vtrans = 0.800242 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:27:04 Magnet Current Measurement: Imag = 10.0030 +- 0.0002 A 12:27:04 Magnet current ramping to 20.0000 A... 12:27:24 Magnet Current, Imag = 20.0558 A Vtrans = 1.604468 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:27:25 Magnet Current, Imag = 20.0556 A Vtrans = 1.604447 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:27:26 Magnet Current, Imag = 20.0559 A Vtrans = 1.604475 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:27:28 Magnet Current, Imag = 20.0554 A Vtrans = 1.604432 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:27:28 Magnet Current Measurement: Imag = 20.0557 +- 0.0002 A 12:27:28 Magnetic Field Measurement Measuring the magnet strength... 12:27:28 Integrated Voltage Measurement... 12:27:53 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.006775967 Vs 12:28:08 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.006755696 Vs 12:28:23 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.006773788 Vs 12:28:38 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.006754180 Vs 12:28:53 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.006775698 Vs 12:29:08 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.006755922 Vs 12:29:23 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.006771876 Vs 12:29:38 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.006757964 Vs 12:29:39 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.006765136 +- 0.000000760 Vs 12:29:39 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.006765136 +- 0.000000760 Vs BL = 0.06765136 +- 0.00000760 Tm 12:29:39 Integrated Voltage Measurement... 12:29:57 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.004580058 Vs 12:30:12 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.004563021 Vs 12:30:28 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.004579431 Vs 12:30:43 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.004564541 Vs 12:30:58 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.004582797 Vs 12:31:13 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.004558850 Vs 12:31:28 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.004584812 Vs 12:31:43 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.004557813 Vs 12:31:43 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.004571415 +- 0.000000419 Vs 12:31:43 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.004571415 +- 0.000000419 Vs BL = 0.04571415 +- 0.00000419 Tm 12:31:43 Integrated Voltage Measurement... 12:32:02 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002397113 Vs 12:32:17 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002365065 Vs 12:32:32 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002400195 Vs 12:32:47 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002365450 Vs 12:33:03 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002400268 Vs 12:33:18 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002370469 Vs 12:33:33 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002394445 Vs 12:33:48 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002367497 Vs 12:33:48 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002382563 +- 0.000001778 Vs 12:33:48 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.002382563 +- 0.000001778 Vs BL = 0.02382563 +- 0.00001778 Tm 12:33:48 Integrated Voltage Measurement... 12:34:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000219391 Vs 12:34:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000188541 Vs 12:34:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000215158 Vs 12:34:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000183602 Vs 12:35:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000219057 Vs 12:35:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000186724 Vs 12:35:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000214106 Vs 12:35:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000190815 Vs 12:35:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000202174 +- 0.000001704 Vs 12:35:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000202174 +- 0.000001704 Vs BL = 0.00202174 +- 0.00001704 Tm 12:35:53 Integrated Voltage Measurement... 12:36:11 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001965660 Vs 12:36:27 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001983755 Vs 12:36:42 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001961983 Vs 12:36:57 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001982453 Vs 12:37:12 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001968004 Vs 12:37:27 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001983742 Vs 12:37:42 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001962923 Vs 12:37:57 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001983272 Vs 12:37:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001973974 +- 0.000001414 Vs 12:37:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001973974 +- 0.000001414 Vs BL = -0.01973974 +- 0.00001414 Tm 12:37:57 Integrated Voltage Measurement... 12:38:16 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.004129256 Vs 12:38:31 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.004148062 Vs 12:38:46 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.004126532 Vs 12:39:01 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.004150619 Vs 12:39:17 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.004115771 Vs 12:39:32 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.004154434 Vs 12:39:47 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.004127185 Vs 12:40:02 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.004137355 Vs 12:40:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.004136152 +- 0.000002661 Vs 12:40:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004136152 +- 0.000002661 Vs BL = -0.04136152 +- 0.00002661 Tm 12:40:02 Integrated Voltage Measurement... 12:40:21 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.006288084 Vs 12:40:36 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.006285309 Vs 12:40:51 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.006294654 Vs 12:41:06 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.006282676 Vs 12:41:21 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.006294556 Vs 12:41:37 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.006288926 Vs 12:41:52 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.006289206 Vs 12:42:07 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.006294981 Vs 12:42:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.006289799 +- 0.000002233 Vs 12:42:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006289799 +- 0.000002233 Vs BL = -0.06289799 +- 0.00002233 Tm 12:42:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00217 0.00001 1 -2.17630 0.00033 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.030000 0.06765 0.00001 0.06746 0.00019 -0.020000 0.04571 0.00000 0.04570 0.00001 -0.010000 0.02383 0.00002 0.02394 -0.00011 0.000000 0.00202 0.00002 0.00217 -0.00015 0.010000 -0.01974 0.00001 -0.01959 -0.00015 0.020000 -0.04136 0.00003 -0.04135 -0.00001 0.030000 -0.06290 0.00002 -0.06312 0.00022 12:42:15 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 7 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.06765 0.00001 -0.0200 0.04571 0.00000 -0.0100 0.02383 0.00002 0.0000 0.00202 0.00002 0.0100 -0.01974 0.00001 0.0200 -0.04136 0.00003 0.0300 -0.06290 0.00002 SL = -2.1763028 +- 0.0003279 Tm^2/m^n 12:42:15 Quadrupole Strength Calculation Check Slope = -2.176303 Tm/m, Inter = 0.002173 Tm, Sig_slope = 0.003175 Tm/m, Est_sig = 0.000168 Tm GL = -2.176303 +- 0.003175 T 12:42:15 Magnet Strength Measurement Harmonic Number = 2 SL = -2.1763028 +- 0.0003279 Tm^2/m^n 12:42:16 Magnet Current, Imag = 20.0570 A Vtrans = 1.604561 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:42:18 Magnet Current, Imag = 20.0572 A Vtrans = 1.604573 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:42:19 Magnet Current, Imag = 20.0571 A Vtrans = 1.604572 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:42:20 Magnet Current, Imag = 20.0570 A Vtrans = 1.604564 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:42:20 Magnet Current Measurement: Imag = 20.0571 +- 0.0001 A 12:42:20 Magnet current ramping to 30.0000 A... 12:42:40 Magnet Current, Imag = 30.1105 A Vtrans = 2.408840 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:42:42 Magnet Current, Imag = 30.1105 A Vtrans = 2.408843 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:42:43 Magnet Current, Imag = 30.1103 A Vtrans = 2.408823 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:42:44 Magnet Current, Imag = 30.1102 A Vtrans = 2.408819 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:42:44 Magnet Current Measurement: Imag = 30.1104 +- 0.0001 A 12:42:44 Magnetic Field Measurement Measuring the magnet strength... 12:42:44 Integrated Voltage Measurement... 12:43:09 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.010103906 Vs 12:43:24 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.010094671 Vs 12:43:39 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.010107012 Vs 12:43:55 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.010090545 Vs 12:44:10 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.010108802 Vs 12:44:25 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.010088461 Vs 12:44:40 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.010102228 Vs 12:44:55 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.010090187 Vs 12:44:55 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.010098226 +- 0.000001191 Vs 12:44:55 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.010098226 +- 0.000001191 Vs BL = 0.10098226 +- 0.00001191 Tm 12:44:55 Integrated Voltage Measurement... 12:45:14 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006831670 Vs 12:45:29 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006818678 Vs 12:45:44 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006835758 Vs 12:45:59 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006813390 Vs 12:46:14 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006835360 Vs 12:46:30 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006809952 Vs 12:46:45 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006844114 Vs 12:47:00 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006813464 Vs 12:47:00 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006825298 +- 0.000002220 Vs 12:47:00 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.006825298 +- 0.000002220 Vs BL = 0.06825298 +- 0.00002220 Tm 12:47:00 Integrated Voltage Measurement... 12:47:19 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003560364 Vs 12:47:34 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003567985 Vs 12:47:49 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003555898 Vs 12:48:04 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003568177 Vs 12:48:19 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003563136 Vs 12:48:34 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003562772 Vs 12:48:49 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003566729 Vs 12:49:05 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003559555 Vs 12:49:05 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003563077 +- 0.000000759 Vs 12:49:05 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003563077 +- 0.000000759 Vs BL = 0.03563077 +- 0.00000759 Tm 12:49:05 Integrated Voltage Measurement... 12:49:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000310125 Vs 12:49:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000298331 Vs 12:49:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000311904 Vs 12:50:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000291993 Vs 12:50:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000321014 Vs 12:50:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000292592 Vs 12:50:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000311135 Vs 12:51:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000300790 Vs 12:51:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000304735 +- 0.000001858 Vs 12:51:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000304735 +- 0.000001858 Vs BL = 0.00304735 +- 0.00001858 Tm 12:51:09 Integrated Voltage Measurement... 12:51:28 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002935780 Vs 12:51:43 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002935104 Vs 12:51:59 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002933574 Vs 12:52:14 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002937118 Vs 12:52:29 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002929376 Vs 12:52:44 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002945747 Vs 12:52:59 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002928624 Vs 12:53:14 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002947388 Vs 12:53:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002936589 +- 0.000001206 Vs 12:53:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002936589 +- 0.000001206 Vs BL = -0.02936589 +- 0.00001206 Tm 12:53:14 Integrated Voltage Measurement... 12:53:33 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.006149638 Vs 12:53:48 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.006182438 Vs 12:54:03 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.006151820 Vs 12:54:18 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.006182567 Vs 12:54:33 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.006151316 Vs 12:54:49 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.006174403 Vs 12:55:04 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.006148982 Vs 12:55:19 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.006179984 Vs 12:55:19 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.006165143 +- 0.000001632 Vs 12:55:19 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006165143 +- 0.000001632 Vs BL = -0.06165143 +- 0.00001632 Tm 12:55:19 Integrated Voltage Measurement... 12:55:38 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.009356632 Vs 12:55:53 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.009380781 Vs 12:56:08 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.009360844 Vs 12:56:23 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.009377794 Vs 12:56:38 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.009380871 Vs 12:56:53 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.009355764 Vs 12:57:08 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.009376033 Vs 12:57:24 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.009369751 Vs 12:57:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.009369809 +- 0.000001816 Vs 12:57:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.009369809 +- 0.000001816 Vs BL = -0.09369809 +- 0.00001816 Tm 12:57:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00331 0.00001 1 -3.24588 0.00031 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.030000 0.10098 0.00001 0.10069 0.00029 -0.020000 0.06825 0.00002 0.06823 0.00002 -0.010000 0.03563 0.00001 0.03577 -0.00014 0.000000 0.00305 0.00002 0.00331 -0.00027 0.010000 -0.02937 0.00001 -0.02914 -0.00022 0.020000 -0.06165 0.00002 -0.06160 -0.00005 0.030000 -0.09370 0.00002 -0.09406 0.00036 12:57:32 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 7 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.10098 0.00001 -0.0200 0.06825 0.00002 -0.0100 0.03563 0.00001 0.0000 0.00305 0.00002 0.0100 -0.02937 0.00001 0.0200 -0.06165 0.00002 0.0300 -0.09370 0.00002 SL = -3.2458805 +- 0.0003089 Tm^2/m^n 12:57:32 Quadrupole Strength Calculation Check Slope = -3.245881 Tm/m, Inter = 0.003314 Tm, Sig_slope = 0.005077 Tm/m, Est_sig = 0.000269 Tm GL = -3.245881 +- 0.005077 T 12:57:32 Magnet Strength Measurement Harmonic Number = 2 SL = -3.2458805 +- 0.0003089 Tm^2/m^n 12:57:33 Magnet Current, Imag = 30.1113 A Vtrans = 2.408906 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:57:34 Magnet Current, Imag = 30.1107 A Vtrans = 2.408858 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:57:36 Magnet Current, Imag = 30.1113 A Vtrans = 2.408907 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:57:37 Magnet Current, Imag = 30.1108 A Vtrans = 2.408868 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:57:37 Magnet Current Measurement: Imag = 30.1111 +- 0.0003 A 12:57:37 Magnet current ramping to 40.0000 A... 12:57:57 Magnet Current, Imag = 40.1815 A Vtrans = 3.214520 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:57:59 Magnet Current, Imag = 40.1821 A Vtrans = 3.214570 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:58:01 Magnet Current, Imag = 40.1819 A Vtrans = 3.214550 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:58:02 Magnet Current, Imag = 40.1818 A Vtrans = 3.214540 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:58:02 Magnet Current Measurement: Imag = 40.1818 +- 0.0002 A 12:58:03 Magnetic Field Measurement Measuring the magnet strength... 12:58:03 Integrated Voltage Measurement... 12:58:28 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.013153515 Vs 12:58:43 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.013166279 Vs 12:58:58 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.013143114 Vs 12:59:13 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.013161299 Vs 12:59:28 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.013154169 Vs 12:59:43 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.013140990 Vs 12:59:58 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.013163596 Vs 13:00:13 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.013136490 Vs 13:00:14 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.013152431 +- 0.000004611 Vs 13:00:14 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.013152431 +- 0.000004611 Vs BL = 0.13152431 +- 0.00004611 Tm 13:00:14 Integrated Voltage Measurement... 13:00:32 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.008902810 Vs 13:00:48 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.008854066 Vs 13:01:03 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.008903635 Vs 13:01:18 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.008870740 Vs 13:01:33 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.008890590 Vs 13:01:48 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.008860408 Vs 13:02:03 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.008886612 Vs 13:02:19 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.008878658 Vs 13:02:19 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.008880940 +- 0.000004409 Vs 13:02:19 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.008880940 +- 0.000004409 Vs BL = 0.08880940 +- 0.00004409 Tm 13:02:19 Integrated Voltage Measurement... 13:02:38 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004630424 Vs 13:02:53 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004597167 Vs 13:03:08 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004631031 Vs 13:03:23 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004590822 Vs 13:03:38 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004632051 Vs 13:03:53 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004595611 Vs 13:04:08 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004630293 Vs 13:04:24 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.004591016 Vs 13:04:24 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.004612302 +- 0.000001515 Vs 13:04:24 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.004612302 +- 0.000001515 Vs BL = 0.04612302 +- 0.00001515 Tm 13:04:24 Integrated Voltage Measurement... 13:04:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000377736 Vs 13:04:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000332404 Vs 13:05:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000385562 Vs 13:05:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000325814 Vs 13:05:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000368196 Vs 13:05:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000354788 Vs 13:06:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000361336 Vs 13:06:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000358001 Vs 13:06:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000357980 +- 0.000002688 Vs 13:06:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000357980 +- 0.000002688 Vs BL = 0.00357980 +- 0.00002688 Tm 13:06:28 Integrated Voltage Measurement... 13:06:47 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003893046 Vs 13:07:02 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003885469 Vs 13:07:18 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003885051 Vs 13:07:33 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003892075 Vs 13:07:48 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003888473 Vs 13:08:03 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003893196 Vs 13:08:18 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003888689 Vs 13:08:33 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003884171 Vs 13:08:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003888771 +- 0.000001583 Vs 13:08:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003888771 +- 0.000001583 Vs BL = -0.03888771 +- 0.00001583 Tm 13:08:33 Integrated Voltage Measurement... 13:08:52 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008120244 Vs 13:09:07 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.008114309 Vs 13:09:22 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008110706 Vs 13:09:38 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.008116899 Vs 13:09:53 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008105840 Vs 13:10:09 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.008120995 Vs 13:10:24 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008113267 Vs 13:10:39 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.008116762 Vs 13:10:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.008114878 +- 0.000001505 Vs 13:10:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.008114878 +- 0.000001505 Vs BL = -0.08114878 +- 0.00001505 Tm 13:10:39 Integrated Voltage Measurement... 13:10:58 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.012321625 Vs 13:11:13 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.012309067 Vs 13:11:28 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.012336076 Vs 13:11:43 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.012314226 Vs 13:11:58 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.012329884 Vs 13:12:14 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.012304894 Vs 13:12:29 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.012325138 Vs 13:12:44 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.012313774 Vs 13:12:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.012319335 +- 0.000003658 Vs 13:12:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.012319335 +- 0.000003658 Vs BL = -0.12319335 +- 0.00003658 Tm 13:12:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00383 0.00001 1 -4.24671 0.00072 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.030000 0.13152 0.00005 0.13123 0.00029 -0.020000 0.08881 0.00004 0.08876 0.00005 -0.010000 0.04612 0.00002 0.04630 -0.00017 0.000000 0.00358 0.00003 0.00383 -0.00025 0.010000 -0.03889 0.00002 -0.03864 -0.00025 0.020000 -0.08115 0.00002 -0.08110 -0.00004 0.030000 -0.12319 0.00004 -0.12357 0.00038 13:12:52 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 7 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.13152 0.00005 -0.0200 0.08881 0.00004 -0.0100 0.04612 0.00002 0.0000 0.00358 0.00003 0.0100 -0.03889 0.00002 0.0200 -0.08115 0.00002 0.0300 -0.12319 0.00004 SL = -4.2467146 +- 0.0007173 Tm^2/m^n 13:12:52 Quadrupole Strength Calculation Check Slope = -4.246715 Tm/m, Inter = 0.003830 Tm, Sig_slope = 0.005267 Tm/m, Est_sig = 0.000279 Tm GL = -4.246715 +- 0.005267 T 13:12:52 Magnet Strength Measurement Harmonic Number = 2 SL = -4.2467146 +- 0.0007173 Tm^2/m^n 13:12:54 Magnet Current, Imag = 40.1824 A Vtrans = 3.214590 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 13:12:55 Magnet Current, Imag = 40.1824 A Vtrans = 3.214590 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 13:12:57 Magnet Current, Imag = 40.1825 A Vtrans = 3.214600 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 13:12:59 Magnet Current, Imag = 40.1831 A Vtrans = 3.214650 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 13:12:59 Magnet Current Measurement: Imag = 40.1826 +- 0.0003 A 13:12:59 Magnet current ramping to 50.0000 A... 13:13:20 Magnet Current, Imag = 50.2911 A Vtrans = 4.023290 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 13:13:21 Magnet Current, Imag = 50.2912 A Vtrans = 4.023300 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 13:13:23 Magnet Current, Imag = 50.2910 A Vtrans = 4.023280 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 13:13:24 Magnet Current, Imag = 50.2910 A Vtrans = 4.023280 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 13:13:24 Magnet Current Measurement: Imag = 50.2911 +- 0.0001 A 13:13:24 Magnetic Field Measurement Measuring the magnet strength... 13:13:24 Integrated Voltage Measurement... 13:13:49 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.015497385 Vs 13:14:04 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.015516265 Vs 13:14:19 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.015507638 Vs 13:14:34 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.015500851 Vs 13:14:50 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.015506509 Vs 13:15:05 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.015494709 Vs 13:15:20 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.015519210 Vs 13:15:35 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.015497130 Vs 13:15:35 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.015504962 +- 0.000002882 Vs 13:15:35 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.015504962 +- 0.000002882 Vs BL = 0.15504962 +- 0.00002882 Tm 13:15:35 Integrated Voltage Measurement... 13:15:54 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.010466211 Vs 13:16:09 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.010443996 Vs 13:16:24 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.010459064 Vs 13:16:39 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.010443732 Vs 13:16:54 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.010468143 Vs 13:17:09 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.010443534 Vs 13:17:24 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.010473445 Vs 13:17:40 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.010431342 Vs 13:17:40 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.010453684 +- 0.000001840 Vs 13:17:40 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.010453684 +- 0.000001840 Vs BL = 0.10453684 +- 0.00001840 Tm 13:17:40 Integrated Voltage Measurement... 13:17:58 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.005426716 Vs 13:18:13 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.005379096 Vs 13:18:29 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.005425842 Vs 13:18:44 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.005380168 Vs 13:18:59 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.005421086 Vs 13:19:14 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.005384477 Vs 13:19:29 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.005415125 Vs 13:19:44 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.005386594 Vs 13:19:44 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.005402388 +- 0.000000886 Vs 13:19:44 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005402388 +- 0.000000886 Vs BL = 0.05402388 +- 0.00000886 Tm 13:19:44 Integrated Voltage Measurement... 13:20:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000366583 Vs 13:20:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000329838 Vs 13:20:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000379554 Vs 13:20:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000328136 Vs 13:21:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000367162 Vs 13:21:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000332688 Vs 13:21:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000356340 Vs 13:21:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000350918 Vs 13:21:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000351402 +- 0.000002413 Vs 13:21:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000351402 +- 0.000002413 Vs BL = 0.00351402 +- 0.00002413 Tm 13:21:49 Integrated Voltage Measurement... 13:22:08 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004696013 Vs 13:22:23 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004697409 Vs 13:22:38 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004684740 Vs 13:22:53 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004696537 Vs 13:23:08 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004681188 Vs 13:23:23 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004692721 Vs 13:23:38 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004683253 Vs 13:23:53 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004689256 Vs 13:23:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004690140 +- 0.000004143 Vs 13:23:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004690140 +- 0.000004143 Vs BL = -0.04690140 +- 0.00004143 Tm 13:23:54 Integrated Voltage Measurement... 13:24:12 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.009711389 Vs 13:24:27 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.009729729 Vs 13:24:43 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.009708626 Vs 13:24:58 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.009724797 Vs 13:25:13 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.009709039 Vs 13:25:28 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.009718817 Vs 13:25:43 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.009707996 Vs 13:25:58 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.009721316 Vs 13:25:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.009716464 +- 0.000002575 Vs 13:25:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.009716464 +- 0.000002575 Vs BL = -0.09716464 +- 0.00002575 Tm 13:25:58 Integrated Voltage Measurement... 13:26:17 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.014698099 Vs 13:26:32 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.014723546 Vs 13:26:47 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.014698276 Vs 13:27:02 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.014737770 Vs 13:27:17 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.014690002 Vs 13:27:33 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.014729582 Vs 13:27:48 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.014690839 Vs 13:28:03 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.014735953 Vs 13:28:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.014713008 +- 0.000003179 Vs 13:28:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.014713008 +- 0.000003179 Vs BL = -0.14713008 +- 0.00003179 Tm 13:28:11 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00370 0.00001 1 -5.03881 0.00053 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.030000 0.15505 0.00003 0.15487 0.00018 -0.020000 0.10454 0.00002 0.10448 0.00006 -0.010000 0.05402 0.00001 0.05409 -0.00007 0.000000 0.00351 0.00002 0.00370 -0.00019 0.010000 -0.04690 0.00004 -0.04668 -0.00022 0.020000 -0.09716 0.00003 -0.09707 -0.00009 0.030000 -0.14713 0.00003 -0.14746 0.00033 13:28:11 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 7 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.15505 0.00003 -0.0200 0.10454 0.00002 -0.0100 0.05402 0.00001 0.0000 0.00351 0.00002 0.0100 -0.04690 0.00004 0.0200 -0.09716 0.00003 0.0300 -0.14713 0.00003 SL = -5.0388119 +- 0.0005342 Tm^2/m^n 13:28:11 Quadrupole Strength Calculation Check Slope = -5.038812 Tm/m, Inter = 0.003704 Tm, Sig_slope = 0.004154 Tm/m, Est_sig = 0.000220 Tm GL = -5.038812 +- 0.004154 T 13:28:11 Magnet Strength Measurement Harmonic Number = 2 SL = -5.0388119 +- 0.0005342 Tm^2/m^n 13:28:12 Magnet Current, Imag = 50.2933 A Vtrans = 4.023460 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 13:28:14 Magnet Current, Imag = 50.2937 A Vtrans = 4.023500 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 13:28:15 Magnet Current, Imag = 50.2933 A Vtrans = 4.023460 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 13:28:17 Magnet Current, Imag = 50.2948 A Vtrans = 4.023580 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 13:28:17 Magnet Current Measurement: Imag = 50.2937 +- 0.0006 A 13:28:17 Magnet current ramping to 60.0000 A... 13:28:37 Magnet Current, Imag = 60.3161 A Vtrans = 4.825290 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 13:28:38 Magnet Current, Imag = 60.3152 A Vtrans = 4.825220 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 13:28:40 Magnet Current, Imag = 60.3150 A Vtrans = 4.825200 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 13:28:41 Magnet Current, Imag = 60.3159 A Vtrans = 4.825270 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 13:28:41 Magnet Current Measurement: Imag = 60.3156 +- 0.0005 A 13:28:41 Magnetic Field Measurement Measuring the magnet strength... 13:28:41 Integrated Voltage Measurement... 13:29:06 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.017296742 Vs 13:29:21 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.017266211 Vs 13:29:36 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.017294334 Vs 13:29:52 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.017274427 Vs 13:30:07 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.017280513 Vs 13:30:22 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.017282882 Vs 13:30:37 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.017280022 Vs 13:30:52 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.017274326 Vs 13:30:52 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.017281182 +- 0.000002581 Vs 13:30:52 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.017281182 +- 0.000002581 Vs BL = 0.17281182 +- 0.00002581 Tm 13:30:52 Integrated Voltage Measurement... 13:31:11 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.011648613 Vs 13:31:26 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.011639604 Vs 13:31:42 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.011656578 Vs 13:31:57 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.011633200 Vs 13:32:12 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.011654967 Vs 13:32:27 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.011646060 Vs 13:32:42 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.011647018 Vs 13:32:57 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.011637343 Vs 13:32:57 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.011645423 +- 0.000003100 Vs 13:32:57 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.011645423 +- 0.000003100 Vs BL = 0.11645423 +- 0.00003100 Tm 13:32:57 Integrated Voltage Measurement... 13:33:16 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.006007204 Vs 13:33:31 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.005993990 Vs 13:33:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.006014259 Vs 13:34:02 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.005979795 Vs 13:34:17 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.006011025 Vs 13:34:32 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.005992715 Vs 13:34:47 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.006003072 Vs 13:35:02 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.005991740 Vs 13:35:02 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.005999225 +- 0.000002063 Vs 13:35:02 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005999225 +- 0.000002063 Vs BL = 0.05999225 +- 0.00002063 Tm 13:35:02 Integrated Voltage Measurement... 13:35:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000362640 Vs 13:35:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000339365 Vs 13:35:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000370617 Vs 13:36:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000327659 Vs 13:36:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000373806 Vs 13:36:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000330091 Vs 13:36:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000371478 Vs 13:37:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000328602 Vs 13:37:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000350532 +- 0.000001050 Vs 13:37:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000350532 +- 0.000001050 Vs BL = 0.00350532 +- 0.00001050 Tm 13:37:07 Integrated Voltage Measurement... 13:37:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.005269008 Vs 13:37:41 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.005305835 Vs 13:37:56 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.005272642 Vs 13:38:11 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.005297191 Vs 13:38:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.005291314 Vs 13:38:41 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.005273857 Vs 13:38:56 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.005297403 Vs 13:39:11 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.005283599 Vs 13:39:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.005286356 +- 0.000002941 Vs 13:39:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005286356 +- 0.000002941 Vs BL = -0.05286356 +- 0.00002941 Tm 13:39:11 Integrated Voltage Measurement... 13:39:30 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.010903039 Vs 13:39:45 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.010902507 Vs 13:40:00 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.010901965 Vs 13:40:16 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.010911847 Vs 13:40:31 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.010892195 Vs 13:40:46 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.010923573 Vs 13:41:01 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.010897625 Vs 13:41:16 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.010920589 Vs 13:41:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.010906667 +- 0.000002380 Vs 13:41:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.010906667 +- 0.000002380 Vs BL = -0.10906667 +- 0.00002380 Tm 13:41:16 Integrated Voltage Measurement... 13:41:35 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.016487547 Vs 13:41:50 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.016515465 Vs 13:42:05 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.016487002 Vs 13:42:20 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.016516790 Vs 13:42:35 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.016486401 Vs 13:42:50 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.016517796 Vs 13:43:06 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.016495254 Vs 13:43:21 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = 0.016520931 Vs 13:43:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = -0.016503398 +- 0.000002719 Vs 13:43:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.016503398 +- 0.000002719 Vs BL = -0.16503398 +- 0.00002719 Tm 13:43:29 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00369 0.00001 1 -5.63370 0.00051 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.030000 0.17281 0.00003 0.17270 0.00012 -0.020000 0.11645 0.00003 0.11636 0.00009 -0.010000 0.05999 0.00002 0.06002 -0.00003 0.000000 0.00351 0.00001 0.00369 -0.00018 0.010000 -0.05286 0.00003 -0.05265 -0.00021 0.020000 -0.10907 0.00002 -0.10899 -0.00008 0.030000 -0.16503 0.00003 -0.16533 0.00029 13:43:29 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 7 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 0.17281 0.00003 -0.0200 0.11645 0.00003 -0.0100 0.05999 0.00002 0.0000 0.00351 0.00001 0.0100 -0.05286 0.00003 0.0200 -0.10907 0.00002 0.0300 -0.16503 0.00003 SL = -5.6336965 +- 0.0005057 Tm^2/m^n 13:43:29 Quadrupole Strength Calculation Check Slope = -5.633697 Tm/m, Inter = 0.003686 Tm, Sig_slope = 0.003701 Tm/m, Est_sig = 0.000196 Tm GL = -5.633697 +- 0.003701 T 13:43:29 Magnet Strength Measurement Harmonic Number = 2 SL = -5.6336965 +- 0.0005057 Tm^2/m^n 13:43:30 Magnet Current, Imag = 60.3175 A Vtrans = 4.825400 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 13:43:32 Magnet Current, Imag = 60.3175 A Vtrans = 4.825400 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 13:43:33 Magnet Current, Imag = 60.3176 A Vtrans = 4.825410 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 13:43:34 Magnet Current, Imag = 60.3182 A Vtrans = 4.825460 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 13:43:34 Magnet Current Measurement: Imag = 60.3177 +- 0.0003 A 13:43:35 Magnet current ramping to 0.0000 A...