SLAC Magnetic Measurements Date: 11-28-2001 Time: 11:15:37 Project: spear3 Magnet Type: quad Magnet Name: Q50-087 Serial Number: Run Number: 1 Measurement Device: ten-turn wire Operator: jy Comment: wire measurement for coil calibration Standardization: 3 cycles from 0.0 A to 98.0 A to 0.0 A Test Currents (A): 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 11:15:44 Initial Zero Current Measurement, Imag_zero = 0.0000 A 11:15:44 Magnet current ramping to 98.0000 A... 11:16:18 Magnet current ramping to 0.0000 A... 11:16:52 Magnet current ramping to 98.0000 A... 11:17:27 Magnet current ramping to 0.0000 A... 11:18:01 Magnet current ramping to 98.0000 A... 11:18:36 Magnet current ramping to 0.0000 A... 11:19:11 Magnet current ramping to 10.0000 A... 11:19:23 Magnet Current, Imag = 9.9947 A Vtrans = 0.799579 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:19:25 Magnet Current, Imag = 9.9911 A Vtrans = 0.799288 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:19:26 Magnet Current, Imag = 9.9912 A Vtrans = 0.799296 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:19:27 Magnet Current, Imag = 9.9919 A Vtrans = 0.799354 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:19:27 Magnet Current Measurement: Imag = 9.9922 +- 0.0015 A 11:19:27 Magnetic Field Measurement Measuring the magnet strength... 11:19:27 Integrated Voltage Measurement... 11:19:50 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.002589718 Vs 11:20:05 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.002594052 Vs 11:20:20 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.002588091 Vs 11:20:35 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.002597693 Vs 11:20:50 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.002590703 Vs 11:21:05 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.002597330 Vs 11:21:20 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.002588282 Vs 11:21:35 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.002608743 Vs 11:21:35 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.002594326 +- 0.000002532 Vs 11:21:35 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002594326 +- 0.000002532 Vs BL = -0.02594326 +- 0.00002532 Tm 11:21:35 Integrated Voltage Measurement... 11:21:53 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.001277522 Vs 11:22:09 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.001302479 Vs 11:22:24 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.001273978 Vs 11:22:39 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.001302135 Vs 11:22:54 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.001272492 Vs 11:23:09 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.001301307 Vs 11:23:24 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.001269534 Vs 11:23:39 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.001300117 Vs 11:23:39 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.001287446 +- 0.000001875 Vs 11:23:39 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001287446 +- 0.000001875 Vs BL = -0.01287446 +- 0.00001875 Tm 11:23:39 Integrated Voltage Measurement... 11:23:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000035025 Vs 11:24:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000013831 Vs 11:24:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000029268 Vs 11:24:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000006350 Vs 11:24:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000035221 Vs 11:25:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000005909 Vs 11:25:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000029549 Vs 11:25:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000014965 Vs 11:25:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000021265 +- 0.000002420 Vs 11:25:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000021265 +- 0.000002420 Vs BL = 0.00021265 +- 0.00002420 Tm 11:25:43 Integrated Voltage Measurement... 11:26:01 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.001335418 Vs 11:26:16 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.001320536 Vs 11:26:31 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.001325018 Vs 11:26:46 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.001320004 Vs 11:27:01 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.001331278 Vs 11:27:16 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.001314457 Vs 11:27:31 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.001337457 Vs 11:27:46 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.001307786 Vs 11:27:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.001323994 +- 0.000002303 Vs 11:27:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.001323994 +- 0.000002303 Vs BL = 0.01323994 +- 0.00002303 Tm 11:27:47 Integrated Voltage Measurement... 11:28:05 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.002644289 Vs 11:28:20 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.002613867 Vs 11:28:35 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.002642534 Vs 11:28:50 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.002616021 Vs 11:29:05 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.002640429 Vs 11:29:20 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.002624007 Vs 11:29:35 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.002637619 Vs 11:29:50 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.002627185 Vs 11:29:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.002630744 +- 0.000001569 Vs 11:29:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.002630744 +- 0.000001569 Vs BL = 0.02630744 +- 0.00001569 Tm 11:29:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00019 0.00001 1 1.30616 0.00067 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 -0.02594 0.00003 -0.02593 -0.00001 -0.010000 -0.01287 0.00002 -0.01287 -0.00000 0.000000 0.00021 0.00002 0.00019 0.00002 0.010000 0.01324 0.00002 0.01325 -0.00001 0.020000 0.02631 0.00002 0.02631 -0.00000 11:29:56 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 -0.02594 0.00003 -0.0100 -0.01287 0.00002 0.0000 0.00021 0.00002 0.0100 0.01324 0.00002 0.0200 0.02631 0.00002 SL = 1.3061581 +- 0.0006656 Tm^2/m^n 11:29:56 Quadrupole Strength Calculation Check Slope = 1.306158 Tm/m, Inter = 0.000188 Tm, Sig_slope = 0.000510 Tm/m, Est_sig = 0.000016 Tm GL = 1.306158 +- 0.000510 T 11:29:56 Magnet Strength Measurement Harmonic Number = 2 SL = 1.3061581 +- 0.0006656 Tm^2/m^n 11:29:57 Magnet Current, Imag = 9.9916 A Vtrans = 0.799325 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:29:58 Magnet Current, Imag = 9.9912 A Vtrans = 0.799298 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:30:00 Magnet Current, Imag = 9.9909 A Vtrans = 0.799273 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:30:01 Magnet Current, Imag = 9.9909 A Vtrans = 0.799269 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:30:01 Magnet Current Measurement: Imag = 9.9911 +- 0.0003 A 11:30:01 Magnet current ramping to 20.0000 A... 11:30:13 Magnet Current, Imag = 20.0316 A Vtrans = 1.602529 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:30:14 Magnet Current, Imag = 20.0316 A Vtrans = 1.602529 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:30:16 Magnet Current, Imag = 20.0327 A Vtrans = 1.602613 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:30:17 Magnet Current, Imag = 20.0330 A Vtrans = 1.602642 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:30:17 Magnet Current Measurement: Imag = 20.0322 +- 0.0006 A 11:30:17 Magnetic Field Measurement Measuring the magnet strength... 11:30:17 Integrated Voltage Measurement... 11:30:39 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005168682 Vs 11:30:54 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.005179417 Vs 11:31:09 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005159132 Vs 11:31:24 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.005183702 Vs 11:31:39 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005157323 Vs 11:31:54 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.005182214 Vs 11:32:09 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005159552 Vs 11:32:24 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.005188868 Vs 11:32:25 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005172361 +- 0.000001863 Vs 11:32:25 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005172361 +- 0.000001863 Vs BL = -0.05172361 +- 0.00001863 Tm 11:32:25 Integrated Voltage Measurement... 11:32:43 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002546625 Vs 11:32:58 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.002580842 Vs 11:33:13 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002552354 Vs 11:33:28 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.002578880 Vs 11:33:43 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002550849 Vs 11:33:58 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.002581160 Vs 11:34:13 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002550166 Vs 11:34:28 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.002575062 Vs 11:34:28 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002564492 +- 0.000001383 Vs 11:34:28 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002564492 +- 0.000001383 Vs BL = -0.02564492 +- 0.00001383 Tm 11:34:28 Integrated Voltage Measurement... 11:34:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000063267 Vs 11:35:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000032642 Vs 11:35:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000067204 Vs 11:35:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000033658 Vs 11:35:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000058094 Vs 11:36:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000036044 Vs 11:36:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000057988 Vs 11:36:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000036055 Vs 11:36:32 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000048119 +- 0.000001386 Vs 11:36:32 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000048119 +- 0.000001386 Vs BL = 0.00048119 +- 0.00001386 Tm 11:36:32 Integrated Voltage Measurement... 11:36:51 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.002667083 Vs 11:37:06 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.002643682 Vs 11:37:21 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.002663801 Vs 11:37:36 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.002646371 Vs 11:37:51 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.002664902 Vs 11:38:06 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.002652258 Vs 11:38:21 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.002657964 Vs 11:38:36 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.002652569 Vs 11:38:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.002656079 +- 0.000001448 Vs 11:38:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.002656079 +- 0.000001448 Vs BL = 0.02656079 +- 0.00001448 Tm 11:38:36 Integrated Voltage Measurement... 11:38:55 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.005274758 Vs 11:39:10 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.005251354 Vs 11:39:25 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.005274382 Vs 11:39:40 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.005253506 Vs 11:39:55 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.005273042 Vs 11:40:11 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.005251247 Vs 11:40:26 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.005274230 Vs 11:40:41 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.005253938 Vs 11:40:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.005263307 +- 0.000000778 Vs 11:40:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005263307 +- 0.000000778 Vs BL = 0.05263307 +- 0.00000778 Tm 11:40:46 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00046 0.00001 1 2.60919 0.00045 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 -0.05172 0.00002 -0.05172 -0.00000 -0.010000 -0.02564 0.00001 -0.02563 -0.00001 0.000000 0.00048 0.00001 0.00046 0.00002 0.010000 0.02656 0.00001 0.02655 0.00001 0.020000 0.05263 0.00001 0.05265 -0.00001 11:40:46 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 -0.05172 0.00002 -0.0100 -0.02564 0.00001 0.0000 0.00048 0.00001 0.0100 0.02656 0.00001 0.0200 0.05263 0.00001 SL = 2.6091907 +- 0.0004507 Tm^2/m^n 11:40:46 Quadrupole Strength Calculation Check Slope = 2.609191 Tm/m, Inter = 0.000461 Tm, Sig_slope = 0.000518 Tm/m, Est_sig = 0.000016 Tm GL = 2.609191 +- 0.000518 T 11:40:46 Magnet Strength Measurement Harmonic Number = 2 SL = 2.6091907 +- 0.0004507 Tm^2/m^n 11:40:47 Magnet Current, Imag = 20.0369 A Vtrans = 1.602949 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:40:49 Magnet Current, Imag = 20.0372 A Vtrans = 1.602977 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:40:50 Magnet Current, Imag = 20.0375 A Vtrans = 1.603004 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:40:51 Magnet Current, Imag = 20.0369 A Vtrans = 1.602952 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:40:51 Magnet Current Measurement: Imag = 20.0371 +- 0.0003 A 11:40:51 Magnet current ramping to 30.0000 A... 11:41:03 Magnet Current, Imag = 30.0786 A Vtrans = 2.406290 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:41:04 Magnet Current, Imag = 30.0794 A Vtrans = 2.406355 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:41:05 Magnet Current, Imag = 30.0804 A Vtrans = 2.406436 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:41:07 Magnet Current, Imag = 30.0802 A Vtrans = 2.406420 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:41:07 Magnet Current Measurement: Imag = 30.0797 +- 0.0007 A 11:41:07 Magnetic Field Measurement Measuring the magnet strength... 11:41:07 Integrated Voltage Measurement... 11:41:29 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.007754511 Vs 11:41:44 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.007786986 Vs 11:41:59 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.007747125 Vs 11:42:14 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.007782246 Vs 11:42:29 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.007754964 Vs 11:42:44 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.007785176 Vs 11:43:00 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.007752553 Vs 11:43:15 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.007786561 Vs 11:43:15 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.007768765 +- 0.000002393 Vs 11:43:15 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.007768765 +- 0.000002393 Vs BL = -0.07768765 +- 0.00002393 Tm 11:43:15 Integrated Voltage Measurement... 11:43:33 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.003826062 Vs 11:43:48 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.003862154 Vs 11:44:03 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.003828054 Vs 11:44:18 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.003862698 Vs 11:44:33 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.003830303 Vs 11:44:49 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.003862530 Vs 11:45:04 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.003829579 Vs 11:45:19 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.003859796 Vs 11:45:19 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.003845147 +- 0.000000859 Vs 11:45:19 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003845147 +- 0.000000859 Vs BL = -0.03845147 +- 0.00000859 Tm 11:45:19 Integrated Voltage Measurement... 11:45:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000087964 Vs 11:45:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000061348 Vs 11:46:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000081956 Vs 11:46:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000064391 Vs 11:46:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000080679 Vs 11:46:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000071683 Vs 11:47:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000081392 Vs 11:47:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000065915 Vs 11:47:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000074416 +- 0.000001151 Vs 11:47:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000074416 +- 0.000001151 Vs BL = 0.00074416 +- 0.00001151 Tm 11:47:23 Integrated Voltage Measurement... 11:47:41 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003996584 Vs 11:47:56 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.003987068 Vs 11:48:11 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003999238 Vs 11:48:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.003990193 Vs 11:48:41 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003995750 Vs 11:48:56 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.003989009 Vs 11:49:11 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003996333 Vs 11:49:27 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.004000082 Vs 11:49:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003994282 +- 0.000002512 Vs 11:49:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003994282 +- 0.000002512 Vs BL = 0.03994282 +- 0.00002512 Tm 11:49:27 Integrated Voltage Measurement... 11:49:45 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.007909083 Vs 11:50:01 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.007913107 Vs 11:50:16 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.007896409 Vs 11:50:31 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.007913997 Vs 11:50:46 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.007920878 Vs 11:51:01 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.007918503 Vs 11:51:16 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.007906972 Vs 11:51:31 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.007911729 Vs 11:51:31 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.007911335 +- 0.000005278 Vs 11:51:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.007911335 +- 0.000005278 Vs BL = 0.07911335 +- 0.00005278 Tm 11:51:36 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00073 0.00001 1 3.91996 0.00119 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 -0.07769 0.00002 -0.07767 -0.00002 -0.010000 -0.03845 0.00001 -0.03847 0.00002 0.000000 0.00074 0.00001 0.00073 0.00001 0.010000 0.03994 0.00003 0.03993 0.00001 0.020000 0.07911 0.00005 0.07913 -0.00002 11:51:36 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 -0.07769 0.00002 -0.0100 -0.03845 0.00001 0.0000 0.00074 0.00001 0.0100 0.03994 0.00003 0.0200 0.07911 0.00005 SL = 3.9199629 +- 0.0011890 Tm^2/m^n 11:51:36 Quadrupole Strength Calculation Check Slope = 3.919963 Tm/m, Inter = 0.000732 Tm, Sig_slope = 0.000651 Tm/m, Est_sig = 0.000021 Tm GL = 3.919963 +- 0.000651 T 11:51:36 Magnet Strength Measurement Harmonic Number = 2 SL = 3.9199629 +- 0.0011890 Tm^2/m^n 11:51:38 Magnet Current, Imag = 30.0811 A Vtrans = 2.406489 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:51:39 Magnet Current, Imag = 30.0812 A Vtrans = 2.406496 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:51:40 Magnet Current, Imag = 30.0809 A Vtrans = 2.406472 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:51:41 Magnet Current, Imag = 30.0812 A Vtrans = 2.406494 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:51:41 Magnet Current Measurement: Imag = 30.0811 +- 0.0001 A 11:51:42 Magnet current ramping to 40.0000 A... 11:51:54 Magnet Current, Imag = 40.1390 A Vtrans = 3.211120 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:51:55 Magnet Current, Imag = 40.1411 A Vtrans = 3.211290 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:51:57 Magnet Current, Imag = 40.1414 A Vtrans = 3.211310 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:51:59 Magnet Current, Imag = 40.1412 A Vtrans = 3.211300 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:51:59 Magnet Current Measurement: Imag = 40.1407 +- 0.0010 A 11:51:59 Magnetic Field Measurement Measuring the magnet strength... 11:51:59 Integrated Voltage Measurement... 11:52:21 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.010355851 Vs 11:52:36 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.010368159 Vs 11:52:51 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.010359012 Vs 11:53:06 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.010366412 Vs 11:53:21 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.010359821 Vs 11:53:36 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.010364732 Vs 11:53:51 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.010364310 Vs 11:54:06 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.010366267 Vs 11:54:07 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.010363070 +- 0.000001305 Vs 11:54:07 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.010363070 +- 0.000001305 Vs BL = -0.10363070 +- 0.00001305 Tm 11:54:07 Integrated Voltage Measurement... 11:54:25 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.005133869 Vs 11:54:40 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.005126193 Vs 11:54:55 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.005129379 Vs 11:55:10 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.005125135 Vs 11:55:25 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.005132592 Vs 11:55:40 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.005125929 Vs 11:55:55 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.005129211 Vs 11:56:10 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.005130084 Vs 11:56:10 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.005129049 +- 0.000001070 Vs 11:56:10 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005129049 +- 0.000001070 Vs BL = -0.05129049 +- 0.00001070 Tm 11:56:10 Integrated Voltage Measurement... 11:56:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000100713 Vs 11:56:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000097087 Vs 11:56:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000108907 Vs 11:57:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000099277 Vs 11:57:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000102399 Vs 11:57:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000103833 Vs 11:57:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000106651 Vs 11:58:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000100161 Vs 11:58:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000102379 +- 0.000002039 Vs 11:58:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000102379 +- 0.000002039 Vs BL = 0.00102379 +- 0.00002039 Tm 11:58:14 Integrated Voltage Measurement... 11:58:33 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.005337310 Vs 11:58:48 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.005329375 Vs 11:59:03 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.005340875 Vs 11:59:18 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.005324202 Vs 11:59:33 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.005343795 Vs 11:59:48 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.005331770 Vs 12:00:03 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.005334540 Vs 12:00:18 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.005333278 Vs 12:00:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.005334393 +- 0.000002017 Vs 12:00:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005334393 +- 0.000002017 Vs BL = 0.05334393 +- 0.00002017 Tm 12:00:18 Integrated Voltage Measurement... 12:00:37 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.010589062 Vs 12:00:52 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.010559814 Vs 12:01:07 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.010560748 Vs 12:01:22 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.010554738 Vs 12:01:37 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.010583058 Vs 12:01:52 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.010554813 Vs 12:02:07 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.010578226 Vs 12:02:22 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.010556504 Vs 12:02:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.010567120 +- 0.000006017 Vs 12:02:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.010567120 +- 0.000006017 Vs BL = 0.10567120 +- 0.00006017 Tm 12:02:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00102 0.00001 1 5.23238 0.00125 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 -0.10363 0.00001 -0.10362 -0.00001 -0.010000 -0.05129 0.00001 -0.05130 0.00001 0.000000 0.00102 0.00002 0.00102 0.00000 0.010000 0.05334 0.00002 0.05335 -0.00000 0.020000 0.10567 0.00006 0.10567 0.00000 12:02:27 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 -0.10363 0.00001 -0.0100 -0.05129 0.00001 0.0000 0.00102 0.00002 0.0100 0.05334 0.00002 0.0200 0.10567 0.00006 SL = 5.2323824 +- 0.0012524 Tm^2/m^n 12:02:27 Quadrupole Strength Calculation Check Slope = 5.232382 Tm/m, Inter = 0.001024 Tm, Sig_slope = 0.000225 Tm/m, Est_sig = 0.000007 Tm GL = 5.232382 +- 0.000225 T 12:02:27 Magnet Strength Measurement Harmonic Number = 2 SL = 5.2323824 +- 0.0012524 Tm^2/m^n 12:02:29 Magnet Current, Imag = 40.1419 A Vtrans = 3.211350 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:02:31 Magnet Current, Imag = 40.1420 A Vtrans = 3.211360 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:02:33 Magnet Current, Imag = 40.1430 A Vtrans = 3.211440 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:02:34 Magnet Current, Imag = 40.1426 A Vtrans = 3.211410 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:02:35 Magnet Current Measurement: Imag = 40.1424 +- 0.0005 A 12:02:35 Magnet current ramping to 50.0000 A... 12:02:47 Magnet Current, Imag = 50.2392 A Vtrans = 4.019140 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:02:48 Magnet Current, Imag = 50.2398 A Vtrans = 4.019180 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:02:49 Magnet Current, Imag = 50.2402 A Vtrans = 4.019220 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:02:51 Magnet Current, Imag = 50.2404 A Vtrans = 4.019230 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:02:51 Magnet Current Measurement: Imag = 50.2399 +- 0.0004 A 12:02:51 Magnetic Field Measurement Measuring the magnet strength... 12:02:51 Integrated Voltage Measurement... 12:03:13 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.012941050 Vs 12:03:28 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.012981039 Vs 12:03:43 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.012947982 Vs 12:03:58 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.012977386 Vs 12:04:13 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.012954614 Vs 12:04:28 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.012971795 Vs 12:04:43 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.012963854 Vs 12:04:59 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.012968894 Vs 12:04:59 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.012963327 +- 0.000001932 Vs 12:04:59 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.012963327 +- 0.000001932 Vs BL = -0.12963327 +- 0.00001932 Tm 12:04:59 Integrated Voltage Measurement... 12:05:17 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.006408356 Vs 12:05:32 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.006420202 Vs 12:05:47 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.006413754 Vs 12:06:02 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.006416607 Vs 12:06:17 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.006417351 Vs 12:06:32 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.006412319 Vs 12:06:47 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.006418508 Vs 12:07:02 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.006410613 Vs 12:07:02 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.006414714 +- 0.000000333 Vs 12:07:02 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006414714 +- 0.000000333 Vs BL = -0.06414714 +- 0.00000333 Tm 12:07:03 Integrated Voltage Measurement... 12:07:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000118183 Vs 12:07:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000140503 Vs 12:07:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000119971 Vs 12:08:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000142780 Vs 12:08:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000121356 Vs 12:08:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000136019 Vs 12:08:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000121391 Vs 12:09:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000125396 Vs 12:09:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000128200 +- 0.000002947 Vs 12:09:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000128200 +- 0.000002947 Vs BL = 0.00128200 +- 0.00002947 Tm 12:09:06 Integrated Voltage Measurement... 12:09:25 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.006683981 Vs 12:09:40 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.006664552 Vs 12:09:55 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.006680526 Vs 12:10:10 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.006668854 Vs 12:10:25 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.006683096 Vs 12:10:40 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.006664367 Vs 12:10:55 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.006691796 Vs 12:11:11 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.006659687 Vs 12:11:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.006674607 +- 0.000000738 Vs 12:11:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.006674607 +- 0.000000738 Vs BL = 0.06674607 +- 0.00000738 Tm 12:11:11 Integrated Voltage Measurement... 12:11:29 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.013242805 Vs 12:11:44 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.013198718 Vs 12:11:59 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.013237854 Vs 12:12:14 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.013205550 Vs 12:12:29 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.013232409 Vs 12:12:44 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.013202719 Vs 12:12:59 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.013242516 Vs 12:13:14 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.013195616 Vs 12:13:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.013219773 +- 0.000001587 Vs 12:13:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.013219773 +- 0.000001587 Vs BL = 0.13219773 +- 0.00001587 Tm 12:13:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00129 0.00001 1 6.54555 0.00051 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 -0.12963 0.00002 -0.12962 -0.00001 -0.010000 -0.06415 0.00000 -0.06417 0.00002 0.000000 0.00128 0.00003 0.00129 -0.00001 0.010000 0.06675 0.00001 0.06674 0.00000 0.020000 0.13220 0.00002 0.13220 -0.00000 12:13:20 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 -0.12963 0.00002 -0.0100 -0.06415 0.00000 0.0000 0.00128 0.00003 0.0100 0.06675 0.00001 0.0200 0.13220 0.00002 SL = 6.5455521 +- 0.0005065 Tm^2/m^n 12:13:20 Quadrupole Strength Calculation Check Slope = 6.545552 Tm/m, Inter = 0.001289 Tm, Sig_slope = 0.000431 Tm/m, Est_sig = 0.000014 Tm GL = 6.545552 +- 0.000431 T 12:13:20 Magnet Strength Measurement Harmonic Number = 2 SL = 6.5455521 +- 0.0005065 Tm^2/m^n 12:13:21 Magnet Current, Imag = 50.2450 A Vtrans = 4.019600 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:13:23 Magnet Current, Imag = 50.2411 A Vtrans = 4.019290 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:13:24 Magnet Current, Imag = 50.2425 A Vtrans = 4.019400 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:13:25 Magnet Current, Imag = 50.2424 A Vtrans = 4.019390 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:13:25 Magnet Current Measurement: Imag = 50.2428 +- 0.0014 A 12:13:26 Magnet current ramping to 60.0000 A... 12:13:37 Magnet Current, Imag = 60.2520 A Vtrans = 4.820160 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:13:39 Magnet Current, Imag = 60.2527 A Vtrans = 4.820220 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:13:40 Magnet Current, Imag = 60.2529 A Vtrans = 4.820230 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:13:41 Magnet Current, Imag = 60.2536 A Vtrans = 4.820290 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:13:41 Magnet Current Measurement: Imag = 60.2528 +- 0.0006 A 12:13:42 Magnetic Field Measurement Measuring the magnet strength... 12:13:42 Integrated Voltage Measurement... 12:14:04 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.015530605 Vs 12:14:19 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.015547025 Vs 12:14:34 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.015522895 Vs 12:14:49 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.015543796 Vs 12:15:04 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.015529082 Vs 12:15:19 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.015547929 Vs 12:15:34 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.015517468 Vs 12:15:50 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.015545814 Vs 12:15:50 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.015535577 +- 0.000003144 Vs 12:15:50 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.015535577 +- 0.000003144 Vs BL = -0.15535577 +- 0.00003144 Tm 12:15:50 Integrated Voltage Measurement... 12:16:08 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.007677331 Vs 12:16:23 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.007696560 Vs 12:16:38 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.007677049 Vs 12:16:53 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.007705659 Vs 12:17:08 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.007669741 Vs 12:17:23 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.007703767 Vs 12:17:39 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.007670733 Vs 12:17:54 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.007703676 Vs 12:17:54 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.007688065 +- 0.000001906 Vs 12:17:54 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.007688065 +- 0.000001906 Vs BL = -0.07688065 +- 0.00001906 Tm 12:17:54 Integrated Voltage Measurement... 12:18:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000170279 Vs 12:18:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000138076 Vs 12:18:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000171563 Vs 12:18:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000150170 Vs 12:19:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000169868 Vs 12:19:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000154509 Vs 12:19:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000164162 Vs 12:19:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000152058 Vs 12:19:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000158836 +- 0.000003065 Vs 12:19:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000158836 +- 0.000003065 Vs BL = 0.00158836 +- 0.00003065 Tm 12:19:58 Integrated Voltage Measurement... 12:20:16 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.008026795 Vs 12:20:31 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.007985968 Vs 12:20:47 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.008009983 Vs 12:21:02 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.007981414 Vs 12:21:17 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.008019228 Vs 12:21:32 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.007986824 Vs 12:21:47 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.008033082 Vs 12:22:02 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.007987719 Vs 12:22:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.008003877 +- 0.000005395 Vs 12:22:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.008003877 +- 0.000005395 Vs BL = 0.08003877 +- 0.00005395 Tm 12:22:02 Integrated Voltage Measurement... 12:22:21 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.015852231 Vs 12:22:36 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.015828376 Vs 12:22:51 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.015865402 Vs 12:23:06 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.015823812 Vs 12:23:22 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.015865303 Vs 12:23:37 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.015822530 Vs 12:23:52 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.015848194 Vs 12:24:07 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.015828549 Vs 12:24:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.015841800 +- 0.000002567 Vs 12:24:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.015841800 +- 0.000002567 Vs BL = 0.15841800 +- 0.00002567 Tm 12:24:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00156 0.00002 1 7.84467 0.00099 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 -0.15536 0.00003 -0.15533 -0.00002 -0.010000 -0.07688 0.00002 -0.07688 0.00000 0.000000 0.00159 0.00003 0.00156 0.00003 0.010000 0.08004 0.00005 0.08001 0.00003 0.020000 0.15842 0.00003 0.15846 -0.00004 12:24:12 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 -0.15536 0.00003 -0.0100 -0.07688 0.00002 0.0000 0.00159 0.00003 0.0100 0.08004 0.00005 0.0200 0.15842 0.00003 SL = 7.8446694 +- 0.0009931 Tm^2/m^n 12:24:12 Quadrupole Strength Calculation Check Slope = 7.844669 Tm/m, Inter = 0.001562 Tm, Sig_slope = 0.001097 Tm/m, Est_sig = 0.000035 Tm GL = 7.844669 +- 0.001097 T 12:24:12 Magnet Strength Measurement Harmonic Number = 2 SL = 7.8446694 +- 0.0009931 Tm^2/m^n 12:24:14 Magnet Current, Imag = 60.2546 A Vtrans = 4.820370 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:24:15 Magnet Current, Imag = 60.2555 A Vtrans = 4.820440 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:24:16 Magnet Current, Imag = 60.2549 A Vtrans = 4.820390 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:24:18 Magnet Current, Imag = 60.2551 A Vtrans = 4.820410 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:24:18 Magnet Current Measurement: Imag = 60.2550 +- 0.0003 A 12:24:18 Magnet current ramping to 70.0000 A... 12:24:30 Magnet Current, Imag = 70.3236 A Vtrans = 5.625890 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:24:31 Magnet Current, Imag = 70.3242 A Vtrans = 5.625940 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:24:32 Magnet Current, Imag = 70.3246 A Vtrans = 5.625970 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:24:34 Magnet Current, Imag = 70.3251 A Vtrans = 5.626010 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:24:34 Magnet Current Measurement: Imag = 70.3244 +- 0.0005 A 12:24:34 Magnetic Field Measurement Measuring the magnet strength... 12:24:34 Integrated Voltage Measurement... 12:24:56 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.018084231 Vs 12:25:11 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.018112727 Vs 12:25:26 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.018091580 Vs 12:25:41 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.018107966 Vs 12:25:56 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.018081276 Vs 12:26:12 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.018113291 Vs 12:26:27 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.018089469 Vs 12:26:42 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.018111383 Vs 12:26:42 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.018098990 +- 0.000001209 Vs 12:26:42 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.018098990 +- 0.000001209 Vs BL = -0.18098990 +- 0.00001209 Tm 12:26:42 Integrated Voltage Measurement... 12:27:00 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.008939723 Vs 12:27:16 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.008959266 Vs 12:27:31 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.008947143 Vs 12:27:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.008961331 Vs 12:28:01 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.008948906 Vs 12:28:16 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.008966862 Vs 12:28:32 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.008954589 Vs 12:28:47 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.008957756 Vs 12:28:47 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.008954447 +- 0.000003137 Vs 12:28:47 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.008954447 +- 0.000003137 Vs BL = -0.08954447 +- 0.00003137 Tm 12:28:47 Integrated Voltage Measurement... 12:29:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000188778 Vs 12:29:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000178918 Vs 12:29:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000188805 Vs 12:29:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000175137 Vs 12:30:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000198921 Vs 12:30:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000168415 Vs 12:30:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000205723 Vs 12:30:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000170438 Vs 12:30:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000184392 +- 0.000002252 Vs 12:30:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000184392 +- 0.000002252 Vs BL = 0.00184392 +- 0.00002252 Tm 12:30:51 Integrated Voltage Measurement... 12:31:09 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.009348561 Vs 12:31:25 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.009305148 Vs 12:31:40 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.009347545 Vs 12:31:55 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.009312074 Vs 12:32:10 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.009333225 Vs 12:32:25 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.009306275 Vs 12:32:40 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.009334840 Vs 12:32:55 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.009317457 Vs 12:32:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.009325641 +- 0.000003668 Vs 12:32:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.009325641 +- 0.000003668 Vs BL = 0.09325641 +- 0.00003668 Tm 12:32:55 Integrated Voltage Measurement... 12:33:13 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.018475472 Vs 12:33:28 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.018446892 Vs 12:33:44 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.018465178 Vs 12:33:59 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.018449805 Vs 12:34:14 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.018475877 Vs 12:34:29 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.018453414 Vs 12:34:44 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.018465173 Vs 12:34:59 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.018458106 Vs 12:34:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.018461240 +- 0.000002540 Vs 12:34:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.018461240 +- 0.000002540 Vs BL = 0.18461240 +- 0.00002540 Tm 12:35:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00184 0.00001 1 9.14005 0.00074 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 -0.18099 0.00001 -0.18097 -0.00002 -0.010000 -0.08954 0.00003 -0.08956 0.00002 0.000000 0.00184 0.00002 0.00184 0.00001 0.010000 0.09326 0.00004 0.09324 0.00002 0.020000 0.18461 0.00003 0.18464 -0.00002 12:35:05 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 -0.18099 0.00001 -0.0100 -0.08954 0.00003 0.0000 0.00184 0.00002 0.0100 0.09326 0.00004 0.0200 0.18461 0.00003 SL = 9.1400547 +- 0.0007413 Tm^2/m^n 12:35:05 Quadrupole Strength Calculation Check Slope = 9.140055 Tm/m, Inter = 0.001836 Tm, Sig_slope = 0.000834 Tm/m, Est_sig = 0.000026 Tm GL = 9.140055 +- 0.000834 T 12:35:05 Magnet Strength Measurement Harmonic Number = 2 SL = 9.1400547 +- 0.0007413 Tm^2/m^n 12:35:06 Magnet Current, Imag = 70.3279 A Vtrans = 5.626230 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:35:07 Magnet Current, Imag = 70.3272 A Vtrans = 5.626180 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:35:09 Magnet Current, Imag = 70.3281 A Vtrans = 5.626250 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:35:10 Magnet Current, Imag = 70.3275 A Vtrans = 5.626200 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:35:10 Magnet Current Measurement: Imag = 70.3277 +- 0.0003 A 12:35:10 Magnet current ramping to 80.0000 A... 12:35:22 Magnet Current, Imag = 80.4531 A Vtrans = 6.436250 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:35:24 Magnet Current, Imag = 80.4541 A Vtrans = 6.436330 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:35:25 Magnet Current, Imag = 80.4549 A Vtrans = 6.436390 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:35:26 Magnet Current, Imag = 80.4545 A Vtrans = 6.436360 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:35:26 Magnet Current Measurement: Imag = 80.4542 +- 0.0007 A 12:35:26 Magnetic Field Measurement Measuring the magnet strength... 12:35:26 Integrated Voltage Measurement... 12:35:49 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.020597545 Vs 12:36:04 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.020585723 Vs 12:36:19 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.020598022 Vs 12:36:34 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.020585638 Vs 12:36:49 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.020620022 Vs 12:37:04 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.020579189 Vs 12:37:19 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.020596717 Vs 12:37:34 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.020578876 Vs 12:37:34 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.020592716 +- 0.000004290 Vs 12:37:34 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.020592716 +- 0.000004290 Vs BL = -0.20592716 +- 0.00004290 Tm 12:37:34 Integrated Voltage Measurement... 12:37:53 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.010197062 Vs 12:38:08 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.010178520 Vs 12:38:23 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.010204978 Vs 12:38:38 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.010186206 Vs 12:38:53 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.010197526 Vs 12:39:08 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.010180761 Vs 12:39:23 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.010205552 Vs 12:39:38 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.010171379 Vs 12:39:38 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.010190248 +- 0.000003122 Vs 12:39:38 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.010190248 +- 0.000003122 Vs BL = -0.10190248 +- 0.00003122 Tm 12:39:38 Integrated Voltage Measurement... 12:39:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000208718 Vs 12:40:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000229287 Vs 12:40:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000206100 Vs 12:40:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000231213 Vs 12:40:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000207859 Vs 12:41:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000223822 Vs 12:41:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000205109 Vs 12:41:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000215556 Vs 12:41:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000215958 +- 0.000003472 Vs 12:41:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000215958 +- 0.000003472 Vs BL = 0.00215958 +- 0.00003472 Tm 12:41:42 Integrated Voltage Measurement... 12:42:00 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.010617698 Vs 12:42:16 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.010614246 Vs 12:42:31 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.010623191 Vs 12:42:46 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.010615312 Vs 12:43:01 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.010620753 Vs 12:43:16 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.010613262 Vs 12:43:31 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.010619965 Vs 12:43:46 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.010604539 Vs 12:43:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.010616121 +- 0.000002529 Vs 12:43:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.010616121 +- 0.000002529 Vs BL = 0.10616121 +- 0.00002529 Tm 12:43:46 Integrated Voltage Measurement... 12:44:04 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.021020874 Vs 12:44:19 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.020996617 Vs 12:44:34 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.021021400 Vs 12:44:49 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.020997945 Vs 12:45:05 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.021013215 Vs 12:45:20 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.021003083 Vs 12:45:35 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.021015946 Vs 12:45:50 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.021004820 Vs 12:45:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.021009237 +- 0.000000856 Vs 12:45:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.021009237 +- 0.000000856 Vs BL = 0.21009237 +- 0.00000856 Tm 12:45:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00212 0.00001 1 10.40103 0.00096 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 -0.20593 0.00004 -0.20590 -0.00002 -0.010000 -0.10190 0.00003 -0.10189 -0.00001 0.000000 0.00216 0.00003 0.00212 0.00004 0.010000 0.10616 0.00003 0.10613 0.00003 0.020000 0.21009 0.00001 0.21014 -0.00004 12:45:55 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 -0.20593 0.00004 -0.0100 -0.10190 0.00003 0.0000 0.00216 0.00003 0.0100 0.10616 0.00003 0.0200 0.21009 0.00001 SL = 10.4010276 +- 0.0009628 Tm^2/m^n 12:45:55 Quadrupole Strength Calculation Check Slope = 10.401028 Tm/m, Inter = 0.002117 Tm, Sig_slope = 0.001372 Tm/m, Est_sig = 0.000043 Tm GL = 10.401028 +- 0.001372 T 12:45:55 Magnet Strength Measurement Harmonic Number = 2 SL = 10.4010276 +- 0.0009628 Tm^2/m^n 12:45:56 Magnet Current, Imag = 80.4596 A Vtrans = 6.436770 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:45:58 Magnet Current, Imag = 80.4589 A Vtrans = 6.436710 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:45:59 Magnet Current, Imag = 80.4595 A Vtrans = 6.436760 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:46:01 Magnet Current, Imag = 80.4594 A Vtrans = 6.436750 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:46:01 Magnet Current Measurement: Imag = 80.4593 +- 0.0003 A 12:46:01 Magnet current ramping to 90.0000 A... 12:46:13 Magnet Current, Imag = 90.4936 A Vtrans = 7.239490 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:46:14 Magnet Current, Imag = 90.4930 A Vtrans = 7.239440 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:46:15 Magnet Current, Imag = 90.4929 A Vtrans = 7.239430 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:46:17 Magnet Current, Imag = 90.4937 A Vtrans = 7.239500 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:46:17 Magnet Current Measurement: Imag = 90.4933 +- 0.0004 A 12:46:17 Magnetic Field Measurement Measuring the magnet strength... 12:46:17 Integrated Voltage Measurement... 12:46:39 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.022773661 Vs 12:46:54 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.022810210 Vs 12:47:09 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.022805730 Vs 12:47:24 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.022811127 Vs 12:47:39 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.022827323 Vs 12:47:55 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.022795070 Vs 12:48:10 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.022839736 Vs 12:48:25 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.022784544 Vs 12:48:25 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.022805925 +- 0.000008191 Vs 12:48:25 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.022805925 +- 0.000008191 Vs BL = -0.22805925 +- 0.00008191 Tm 12:48:25 Integrated Voltage Measurement... 12:48:44 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.011292454 Vs 12:48:59 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.011261757 Vs 12:49:14 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.011285673 Vs 12:49:29 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.011241217 Vs 12:49:44 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.011296411 Vs 12:49:59 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.011258227 Vs 12:50:14 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.011295836 Vs 12:50:29 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.011262186 Vs 12:50:29 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.011274220 +- 0.000006265 Vs 12:50:29 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.011274220 +- 0.000006265 Vs BL = -0.11274220 +- 0.00006265 Tm 12:50:29 Integrated Voltage Measurement... 12:50:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000232694 Vs 12:51:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000235969 Vs 12:51:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000232451 Vs 12:51:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000238241 Vs 12:51:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000243226 Vs 12:52:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000233704 Vs 12:52:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000237659 Vs 12:52:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000242178 Vs 12:52:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000237015 +- 0.000002265 Vs 12:52:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000237015 +- 0.000002265 Vs BL = 0.00237015 +- 0.00002265 Tm 12:52:33 Integrated Voltage Measurement... 12:52:52 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.011757182 Vs 12:53:07 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.011756729 Vs 12:53:22 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.011747026 Vs 12:53:37 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.011753947 Vs 12:53:52 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.011749512 Vs 12:54:07 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.011757235 Vs 12:54:22 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.011753984 Vs 12:54:37 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.011753685 Vs 12:54:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.011753662 +- 0.000002294 Vs 12:54:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.011753662 +- 0.000002294 Vs BL = 0.11753662 +- 0.00002294 Tm 12:54:37 Integrated Voltage Measurement... 12:54:55 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.023272157 Vs 12:55:10 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.023258915 Vs 12:55:25 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.023265707 Vs 12:55:40 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.023257523 Vs 12:55:56 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.023273780 Vs 12:56:11 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.023250888 Vs 12:56:26 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.023277846 Vs 12:56:41 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.023232301 Vs 12:56:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.023261140 +- 0.000003801 Vs 12:56:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.023261140 +- 0.000003801 Vs BL = 0.23261140 +- 0.00003801 Tm 12:56:46 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00234 0.00002 1 11.51620 0.00193 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 -0.22806 0.00008 -0.22798 -0.00008 -0.010000 -0.11274 0.00006 -0.11282 0.00008 0.000000 0.00237 0.00002 0.00234 0.00003 0.010000 0.11754 0.00002 0.11751 0.00003 0.020000 0.23261 0.00004 0.23267 -0.00006 12:56:46 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 -0.22806 0.00008 -0.0100 -0.11274 0.00006 0.0000 0.00237 0.00002 0.0100 0.11754 0.00002 0.0200 0.23261 0.00004 SL = 11.5162012 +- 0.0019253 Tm^2/m^n 12:56:46 Quadrupole Strength Calculation Check Slope = 11.516201 Tm/m, Inter = 0.002343 Tm, Sig_slope = 0.002370 Tm/m, Est_sig = 0.000075 Tm GL = 11.516201 +- 0.002370 T 12:56:46 Magnet Strength Measurement Harmonic Number = 2 SL = 11.5162012 +- 0.0019253 Tm^2/m^n 12:56:48 Magnet Current, Imag = 90.4996 A Vtrans = 7.239970 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:56:49 Magnet Current, Imag = 90.4998 A Vtrans = 7.239980 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:56:51 Magnet Current, Imag = 90.5009 A Vtrans = 7.240070 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:56:52 Magnet Current, Imag = 90.4989 A Vtrans = 7.239910 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 12:56:52 Magnet Current Measurement: Imag = 90.4998 +- 0.0007 A 12:56:53 Magnet current ramping to 0.0000 A...