SLAC Magnetic Measurements Date: 12-06-2001 Time: 13:51:44 Project: spear3 Magnet Type: quadrupole Magnet Name: Q15-004 Serial Number: Run Number: 1 Measurement Device: ten-turn wire Operator: jy Comment: strength vs. current meas for coil calibration Standardization: 3 cycles from 0.0 A to 98.0 A to 0.0 A Test Currents (A): 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 13:51:49 Initial Zero Current Measurement, Imag_zero = 0.0000 A 13:51:49 Magnet current ramping to 98.0000 A... 13:52:23 Magnet current ramping to 0.0000 A... 13:52:57 Magnet current ramping to 98.0000 A... 13:53:33 Magnet current ramping to 0.0000 A... 13:54:07 Magnet current ramping to 98.0000 A... 13:54:41 Magnet current ramping to 0.0000 A... 13:55:16 Magnet current ramping to 10.0000 A... 13:55:29 Magnet Current, Imag = 9.9982 A Vtrans = 0.099982 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:31 Magnet Current, Imag = 9.9971 A Vtrans = 0.099971 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:33 Magnet Current, Imag = 9.9973 A Vtrans = 0.099973 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:34 Magnet Current, Imag = 9.9969 A Vtrans = 0.099969 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:34 Magnet Current Measurement: Imag = 9.9974 +- 0.0005 A 13:55:34 Magnetic Field Measurement Measuring the magnet strength... 13:55:35 Integrated Voltage Measurement... 13:55:57 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000904669 Vs 13:56:12 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.000744528 Vs 13:56:27 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000930050 Vs 13:56:42 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.000702545 Vs 13:56:57 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000983888 Vs 13:57:12 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.000673411 Vs 13:57:27 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000961618 Vs 13:57:42 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.000699817 Vs 13:57:42 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.000825066 +- 0.000005520 Vs 13:57:42 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000825066 +- 0.000005520 Vs BL = 0.00825066 +- 0.00005520 Tm 13:57:42 Integrated Voltage Measurement... 13:58:01 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000550643 Vs 13:58:16 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000262047 Vs 13:58:31 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000571526 Vs 13:58:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000250496 Vs 13:59:01 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000551931 Vs 13:59:16 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000289858 Vs 13:59:31 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000536474 Vs 13:59:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000277719 Vs 13:59:46 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000411337 +- 0.000005796 Vs 13:59:46 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000411337 +- 0.000005796 Vs BL = 0.00411337 +- 0.00005796 Tm 13:59:46 Integrated Voltage Measurement... 14:00:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000158589 Vs 14:00:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000179832 Vs 14:00:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000159430 Vs 14:00:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000158239 Vs 14:01:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000153041 Vs 14:01:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000159283 Vs 14:01:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000157278 Vs 14:01:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000163875 Vs 14:01:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000004111 +- 0.000004067 Vs 14:01:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000004111 +- 0.000004067 Vs BL = -0.00004111 +- 0.00004067 Tm 14:01:50 Integrated Voltage Measurement... 14:02:09 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000258378 Vs 14:02:24 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000581111 Vs 14:02:39 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000258869 Vs 14:02:54 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000576667 Vs 14:03:09 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000261011 Vs 14:03:24 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000560601 Vs 14:03:39 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000302011 Vs 14:03:54 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000530514 Vs 14:03:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000416145 +- 0.000003321 Vs 14:03:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000416145 +- 0.000003321 Vs BL = -0.00416145 +- 0.00003321 Tm 14:03:54 Integrated Voltage Measurement... 14:04:13 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000718279 Vs 14:04:28 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.000969528 Vs 14:04:43 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000690630 Vs 14:04:58 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.000990056 Vs 14:05:13 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000695589 Vs 14:05:28 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.000953568 Vs 14:05:43 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000733733 Vs 14:05:58 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.000927499 Vs 14:05:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.000834860 +- 0.000007674 Vs 14:05:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000834860 +- 0.000007674 Vs BL = -0.00834860 +- 0.00007674 Tm 14:06:03 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00004 0.00002 1 -0.41473 0.00201 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 0.00825 0.00006 0.00826 -0.00001 -0.010000 0.00411 0.00006 0.00411 0.00000 0.000000 -0.00004 0.00004 -0.00004 -0.00000 0.010000 -0.00416 0.00003 -0.00418 0.00002 0.020000 -0.00835 0.00008 -0.00833 -0.00002 14:06:03 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 0.00825 0.00006 -0.0100 0.00411 0.00006 0.0000 -0.00004 0.00004 0.0100 -0.00416 0.00003 0.0200 -0.00835 0.00008 SL = -0.4147334 +- 0.0020052 Tm^2/m^n 14:06:03 Quadrupole Strength Calculation Check Slope = -0.414733 Tm/m, Inter = -0.000037 Tm, Sig_slope = 0.000543 Tm/m, Est_sig = 0.000017 Tm GL = -0.414733 +- 0.000543 T 14:06:03 Magnet Strength Measurement Harmonic Number = 2 SL = -0.4147334 +- 0.0020052 Tm^2/m^n 14:06:05 Magnet Current, Imag = 9.9979 A Vtrans = 0.099979 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:07 Magnet Current, Imag = 9.9972 A Vtrans = 0.099972 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:09 Magnet Current, Imag = 9.9974 A Vtrans = 0.099974 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:11 Magnet Current, Imag = 9.9967 A Vtrans = 0.099967 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:11 Magnet Current Measurement: Imag = 9.9973 +- 0.0004 A 14:06:11 Magnet current ramping to 20.0000 A... 14:06:23 Magnet Current, Imag = 20.0389 A Vtrans = 0.200388 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:25 Magnet Current, Imag = 20.0392 A Vtrans = 0.200392 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:27 Magnet Current, Imag = 20.0392 A Vtrans = 0.200392 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:28 Magnet Current, Imag = 20.0390 A Vtrans = 0.200390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:28 Magnet Current Measurement: Imag = 20.0391 +- 0.0002 A 14:06:28 Magnetic Field Measurement Measuring the magnet strength... 14:06:28 Integrated Voltage Measurement... 14:06:51 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.001750125 Vs 14:07:06 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.001560931 Vs 14:07:21 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.001771897 Vs 14:07:36 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.001533801 Vs 14:07:51 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.001794900 Vs 14:08:06 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.001539629 Vs 14:08:21 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.001798422 Vs 14:08:36 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.001508315 Vs 14:08:36 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.001657252 +- 0.000005867 Vs 14:08:36 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.001657252 +- 0.000005867 Vs BL = 0.01657252 +- 0.00005867 Tm 14:08:36 Integrated Voltage Measurement... 14:08:55 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001015151 Vs 14:09:10 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000658444 Vs 14:09:25 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000995803 Vs 14:09:40 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000663938 Vs 14:09:55 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001004315 Vs 14:10:10 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000646769 Vs 14:10:26 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001019935 Vs 14:10:41 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000656602 Vs 14:10:41 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000832620 +- 0.000005172 Vs 14:10:41 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000832620 +- 0.000005172 Vs BL = 0.00832620 +- 0.00005172 Tm 14:10:41 Integrated Voltage Measurement... 14:10:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000164980 Vs 14:11:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000157456 Vs 14:11:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000146701 Vs 14:11:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000150405 Vs 14:12:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000160482 Vs 14:12:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000176457 Vs 14:12:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000196672 Vs 14:12:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000194319 Vs 14:12:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000001225 +- 0.000004381 Vs 14:12:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000001225 +- 0.000004381 Vs BL = -0.00001225 +- 0.00004381 Tm 14:12:45 Integrated Voltage Measurement... 14:13:03 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000650121 Vs 14:13:18 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000992749 Vs 14:13:33 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000691597 Vs 14:13:48 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000946686 Vs 14:14:03 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000714164 Vs 14:14:18 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000964768 Vs 14:14:33 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000712105 Vs 14:14:49 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.000948146 Vs 14:14:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000827542 +- 0.000008011 Vs 14:14:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000827542 +- 0.000008011 Vs BL = -0.00827542 +- 0.00008011 Tm 14:14:49 Integrated Voltage Measurement... 14:15:07 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.001539095 Vs 14:15:22 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.001765904 Vs 14:15:37 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.001591013 Vs 14:15:53 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.001741223 Vs 14:16:08 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.001568115 Vs 14:16:23 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.001768822 Vs 14:16:38 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.001566010 Vs 14:16:53 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.001759554 Vs 14:16:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.001662467 +- 0.000006099 Vs 14:16:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001662467 +- 0.000006099 Vs BL = -0.01662467 +- 0.00006099 Tm 14:16:58 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00000 0.00003 1 -0.82996 0.00194 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 0.01657 0.00006 0.01660 -0.00002 -0.010000 0.00833 0.00005 0.00830 0.00003 0.000000 -0.00001 0.00004 -0.00000 -0.00001 0.010000 -0.00828 0.00008 -0.00830 0.00003 0.020000 -0.01662 0.00006 -0.01660 -0.00002 14:16:58 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 0.01657 0.00006 -0.0100 0.00833 0.00005 0.0000 -0.00001 0.00004 0.0100 -0.00828 0.00008 0.0200 -0.01662 0.00006 SL = -0.8299600 +- 0.0019427 Tm^2/m^n 14:16:58 Quadrupole Strength Calculation Check Slope = -0.829960 Tm/m, Inter = -0.000003 Tm, Sig_slope = 0.000960 Tm/m, Est_sig = 0.000030 Tm GL = -0.829960 +- 0.000960 T 14:16:58 Magnet Strength Measurement Harmonic Number = 2 SL = -0.8299600 +- 0.0019427 Tm^2/m^n 14:17:00 Magnet Current, Imag = 20.0397 A Vtrans = 0.200397 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:02 Magnet Current, Imag = 20.0403 A Vtrans = 0.200403 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:04 Magnet Current, Imag = 20.0402 A Vtrans = 0.200402 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:05 Magnet Current, Imag = 20.0391 A Vtrans = 0.200391 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:05 Magnet Current Measurement: Imag = 20.0398 +- 0.0004 A 14:17:06 Magnet current ramping to 30.0000 A... 14:17:18 Magnet Current, Imag = 30.0837 A Vtrans = 0.300837 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:19 Magnet Current, Imag = 30.0839 A Vtrans = 0.300839 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:20 Magnet Current, Imag = 30.0837 A Vtrans = 0.300837 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:21 Magnet Current, Imag = 30.0837 A Vtrans = 0.300837 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:21 Magnet Current Measurement: Imag = 30.0838 +- 0.0001 A 14:17:21 Magnetic Field Measurement Measuring the magnet strength... 14:17:22 Integrated Voltage Measurement... 14:17:44 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002691295 Vs 14:17:59 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.002297589 Vs 14:18:14 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002707225 Vs 14:18:29 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.002324765 Vs 14:18:44 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002669919 Vs 14:18:59 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.002325541 Vs 14:19:14 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002683393 Vs 14:19:29 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.002310063 Vs 14:19:29 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.002501224 +- 0.000008611 Vs 14:19:29 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.002501224 +- 0.000008611 Vs BL = 0.02501224 +- 0.00008611 Tm 14:19:29 Integrated Voltage Measurement... 14:19:48 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001472743 Vs 14:20:03 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001035465 Vs 14:20:18 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001460890 Vs 14:20:33 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001049921 Vs 14:20:48 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001464435 Vs 14:21:03 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001063534 Vs 14:21:18 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001441361 Vs 14:21:33 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001069839 Vs 14:21:33 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001257273 +- 0.000003917 Vs 14:21:33 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.001257273 +- 0.000003917 Vs BL = 0.01257273 +- 0.00003917 Tm 14:21:33 Integrated Voltage Measurement... 14:21:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000181848 Vs 14:22:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000157506 Vs 14:22:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000150083 Vs 14:22:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000128726 Vs 14:22:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000145889 Vs 14:23:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000148369 Vs 14:23:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000155450 Vs 14:23:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000156950 Vs 14:23:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000005215 +- 0.000006235 Vs 14:23:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000005215 +- 0.000006235 Vs BL = 0.00005215 +- 0.00006235 Tm 14:23:37 Integrated Voltage Measurement... 14:23:56 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001084880 Vs 14:24:11 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001391244 Vs 14:24:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001100900 Vs 14:24:41 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001380718 Vs 14:24:56 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001116906 Vs 14:25:11 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001380535 Vs 14:25:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001100661 Vs 14:25:41 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001412817 Vs 14:25:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001246082 +- 0.000007292 Vs 14:25:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001246082 +- 0.000007292 Vs BL = -0.01246082 +- 0.00007292 Tm 14:25:41 Integrated Voltage Measurement... 14:26:00 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002342291 Vs 14:26:15 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002628729 Vs 14:26:30 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002362456 Vs 14:26:45 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002633316 Vs 14:27:00 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002356981 Vs 14:27:15 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002631065 Vs 14:27:30 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002374908 Vs 14:27:45 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.002608982 Vs 14:27:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.002492341 +- 0.000004483 Vs 14:27:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002492341 +- 0.000004483 Vs BL = -0.02492341 +- 0.00004483 Tm 14:27:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00005 0.00003 1 -1.24905 0.00211 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 0.02501 0.00009 0.02503 -0.00002 -0.010000 0.01257 0.00004 0.01254 0.00003 0.000000 0.00005 0.00006 0.00005 0.00000 0.010000 -0.01246 0.00007 -0.01244 -0.00002 0.020000 -0.02492 0.00004 -0.02493 0.00001 14:27:51 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 0.02501 0.00009 -0.0100 0.01257 0.00004 0.0000 0.00005 0.00006 0.0100 -0.01246 0.00007 0.0200 -0.02492 0.00004 SL = -1.2490485 +- 0.0021107 Tm^2/m^n 14:27:51 Quadrupole Strength Calculation Check Slope = -1.249049 Tm/m, Inter = 0.000051 Tm, Sig_slope = 0.000788 Tm/m, Est_sig = 0.000025 Tm GL = -1.249049 +- 0.000788 T 14:27:51 Magnet Strength Measurement Harmonic Number = 2 SL = -1.2490485 +- 0.0021107 Tm^2/m^n 14:27:52 Magnet Current, Imag = 30.0836 A Vtrans = 0.300836 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:27:53 Magnet Current, Imag = 30.0841 A Vtrans = 0.300841 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:27:55 Magnet Current, Imag = 30.0838 A Vtrans = 0.300838 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:27:56 Magnet Current, Imag = 30.0841 A Vtrans = 0.300841 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:27:56 Magnet Current Measurement: Imag = 30.0839 +- 0.0002 A 14:27:56 Magnet current ramping to 40.0000 A... 14:28:07 Magnet Current, Imag = 40.1448 A Vtrans = 0.401448 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:28:09 Magnet Current, Imag = 40.1443 A Vtrans = 0.401443 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:28:10 Magnet Current, Imag = 40.1447 A Vtrans = 0.401447 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:28:11 Magnet Current, Imag = 40.1446 A Vtrans = 0.401446 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:28:11 Magnet Current Measurement: Imag = 40.1446 +- 0.0002 A 14:28:11 Magnetic Field Measurement Measuring the magnet strength... 14:28:11 Integrated Voltage Measurement... 14:28:34 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003479817 Vs 14:28:49 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003215275 Vs 14:29:04 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003460509 Vs 14:29:19 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003224484 Vs 14:29:34 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003480666 Vs 14:29:49 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003192331 Vs 14:30:04 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003484142 Vs 14:30:19 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003198826 Vs 14:30:19 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003342006 +- 0.000003922 Vs 14:30:19 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003342006 +- 0.000003922 Vs BL = 0.03342006 +- 0.00003922 Tm 14:30:19 Integrated Voltage Measurement... 14:30:38 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001807683 Vs 14:30:53 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001553471 Vs 14:31:08 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001799378 Vs 14:31:23 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001546505 Vs 14:31:38 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001802976 Vs 14:31:53 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001534113 Vs 14:32:08 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001815644 Vs 14:32:23 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001519636 Vs 14:32:23 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001672426 +- 0.000005116 Vs 14:32:23 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.001672426 +- 0.000005116 Vs BL = 0.01672426 +- 0.00005116 Tm 14:32:23 Integrated Voltage Measurement... 14:32:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000146619 Vs 14:32:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000127739 Vs 14:33:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000132265 Vs 14:33:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000117392 Vs 14:33:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000154416 Vs 14:33:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000126225 Vs 14:34:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000114177 Vs 14:34:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000084888 Vs 14:34:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000011404 +- 0.000003055 Vs 14:34:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000011404 +- 0.000003055 Vs BL = 0.00011404 +- 0.00003055 Tm 14:34:27 Integrated Voltage Measurement... 14:34:45 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001574992 Vs 14:35:01 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001730133 Vs 14:35:16 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001596878 Vs 14:35:31 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001740493 Vs 14:35:46 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001560036 Vs 14:36:01 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001768382 Vs 14:36:16 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001506509 Vs 14:36:31 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001829004 Vs 14:36:31 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001663303 +- 0.000006422 Vs 14:36:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001663303 +- 0.000006422 Vs BL = -0.01663303 +- 0.00006422 Tm 14:36:31 Integrated Voltage Measurement... 14:36:49 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.003141673 Vs 14:37:04 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.003514505 Vs 14:37:19 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.003156970 Vs 14:37:35 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.003482132 Vs 14:37:50 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.003166751 Vs 14:38:05 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.003478586 Vs 14:38:20 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.003195632 Vs 14:38:35 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.003454696 Vs 14:38:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.003323868 +- 0.000003145 Vs 14:38:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003323868 +- 0.000003145 Vs BL = -0.03323868 +- 0.00003145 Tm 14:38:40 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00008 0.00002 1 -1.66675 0.00130 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 0.03342 0.00004 0.03341 0.00001 -0.010000 0.01672 0.00005 0.01674 -0.00002 0.000000 0.00011 0.00003 0.00008 0.00004 0.010000 -0.01663 0.00006 -0.01659 -0.00004 0.020000 -0.03324 0.00003 -0.03326 0.00002 14:38:40 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 0.03342 0.00004 -0.0100 0.01672 0.00005 0.0000 0.00011 0.00003 0.0100 -0.01663 0.00006 0.0200 -0.03324 0.00003 SL = -1.6667477 +- 0.0012982 Tm^2/m^n 14:38:41 Quadrupole Strength Calculation Check Slope = -1.666748 Tm/m, Inter = 0.000077 Tm, Sig_slope = 0.001159 Tm/m, Est_sig = 0.000037 Tm GL = -1.666748 +- 0.001159 T 14:38:41 Magnet Strength Measurement Harmonic Number = 2 SL = -1.6667477 +- 0.0012982 Tm^2/m^n 14:38:42 Magnet Current, Imag = 40.1451 A Vtrans = 0.401451 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:38:43 Magnet Current, Imag = 40.1454 A Vtrans = 0.401454 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:38:44 Magnet Current, Imag = 40.1454 A Vtrans = 0.401454 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:38:46 Magnet Current, Imag = 40.1450 A Vtrans = 0.401450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:38:46 Magnet Current Measurement: Imag = 40.1452 +- 0.0002 A 14:38:46 Magnet current ramping to 50.0000 A... 14:38:57 Magnet Current, Imag = 50.2446 A Vtrans = 0.502446 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:38:59 Magnet Current, Imag = 50.2442 A Vtrans = 0.502442 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:00 Magnet Current, Imag = 50.2448 A Vtrans = 0.502448 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:01 Magnet Current, Imag = 50.2452 A Vtrans = 0.502452 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:01 Magnet Current Measurement: Imag = 50.2447 +- 0.0004 A 14:39:01 Magnetic Field Measurement Measuring the magnet strength... 14:39:01 Integrated Voltage Measurement... 14:39:24 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.004325388 Vs 14:39:39 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.004028888 Vs 14:39:54 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.004343123 Vs 14:40:09 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.004017923 Vs 14:40:24 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.004352272 Vs 14:40:39 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003991392 Vs 14:40:54 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.004393328 Vs 14:41:10 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003966506 Vs 14:41:10 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.004177352 +- 0.000003433 Vs 14:41:10 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.004177352 +- 0.000003433 Vs BL = 0.04177352 +- 0.00003433 Tm 14:41:10 Integrated Voltage Measurement... 14:41:28 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002305965 Vs 14:41:43 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001894029 Vs 14:41:58 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002291115 Vs 14:42:13 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001901268 Vs 14:42:28 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002313682 Vs 14:42:43 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001858166 Vs 14:42:58 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002326453 Vs 14:43:13 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001885576 Vs 14:43:13 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002097032 +- 0.000007307 Vs 14:43:14 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.002097032 +- 0.000007307 Vs BL = 0.02097032 +- 0.00007307 Tm 14:43:14 Integrated Voltage Measurement... 14:43:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000218854 Vs 14:43:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000212392 Vs 14:44:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000205843 Vs 14:44:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000154395 Vs 14:44:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000176598 Vs 14:44:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000178602 Vs 14:45:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000199852 Vs 14:45:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000175948 Vs 14:45:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000009976 +- 0.000010221 Vs 14:45:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000009976 +- 0.000010221 Vs BL = 0.00009976 +- 0.00010221 Tm 14:45:18 Integrated Voltage Measurement... 14:45:37 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001906342 Vs 14:45:52 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002232992 Vs 14:46:07 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001920803 Vs 14:46:22 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002233906 Vs 14:46:37 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001906775 Vs 14:46:52 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002256554 Vs 14:47:07 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001892280 Vs 14:47:22 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002260130 Vs 14:47:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002076223 +- 0.000004298 Vs 14:47:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002076223 +- 0.000004298 Vs BL = -0.02076223 +- 0.00004298 Tm 14:47:22 Integrated Voltage Measurement... 14:47:41 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.003960597 Vs 14:47:56 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.004351192 Vs 14:48:11 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.003989202 Vs 14:48:26 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.004311236 Vs 14:48:41 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.004027415 Vs 14:48:56 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.004290782 Vs 14:49:11 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.004027543 Vs 14:49:27 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.004302007 Vs 14:49:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.004157497 +- 0.000005269 Vs 14:49:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004157497 +- 0.000005269 Vs BL = -0.04157497 +- 0.00005269 Tm 14:49:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00010 0.00003 1 -2.08430 0.00152 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 0.04177 0.00003 0.04179 -0.00001 -0.010000 0.02097 0.00007 0.02094 0.00003 0.000000 0.00010 0.00010 0.00010 -0.00000 0.010000 -0.02076 0.00004 -0.02074 -0.00002 0.020000 -0.04157 0.00005 -0.04158 0.00001 14:49:32 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 0.04177 0.00003 -0.0100 0.02097 0.00007 0.0000 0.00010 0.00010 0.0100 -0.02076 0.00004 0.0200 -0.04157 0.00005 SL = -2.0842953 +- 0.0015168 Tm^2/m^n 14:49:32 Quadrupole Strength Calculation Check Slope = -2.084295 Tm/m, Inter = 0.000101 Tm, Sig_slope = 0.000680 Tm/m, Est_sig = 0.000021 Tm GL = -2.084295 +- 0.000680 T 14:49:32 Magnet Strength Measurement Harmonic Number = 2 SL = -2.0842953 +- 0.0015168 Tm^2/m^n 14:49:33 Magnet Current, Imag = 50.2450 A Vtrans = 0.502450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:35 Magnet Current, Imag = 50.2454 A Vtrans = 0.502454 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:36 Magnet Current, Imag = 50.2455 A Vtrans = 0.502455 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:37 Magnet Current, Imag = 50.2452 A Vtrans = 0.502452 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:37 Magnet Current Measurement: Imag = 50.2453 +- 0.0002 A 14:49:37 Magnet current ramping to 60.0000 A... 14:49:49 Magnet Current, Imag = 60.2580 A Vtrans = 0.602580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:50 Magnet Current, Imag = 60.2582 A Vtrans = 0.602582 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:51 Magnet Current, Imag = 60.2581 A Vtrans = 0.602581 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:53 Magnet Current, Imag = 60.2586 A Vtrans = 0.602586 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:53 Magnet Current Measurement: Imag = 60.2582 +- 0.0002 A 14:49:53 Magnetic Field Measurement Measuring the magnet strength... 14:49:53 Integrated Voltage Measurement... 14:50:15 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005145186 Vs 14:50:30 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.004874923 Vs 14:50:45 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005129250 Vs 14:51:00 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.004901007 Vs 14:51:15 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005122301 Vs 14:51:30 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.004902241 Vs 14:51:45 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005109731 Vs 14:52:01 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.004914123 Vs 14:52:01 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005012345 +- 0.000001815 Vs 14:52:01 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005012345 +- 0.000001815 Vs BL = 0.05012345 +- 0.00001815 Tm 14:52:01 Integrated Voltage Measurement... 14:52:19 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002608864 Vs 14:52:34 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002409599 Vs 14:52:49 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002621062 Vs 14:53:04 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002384388 Vs 14:53:19 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002654974 Vs 14:53:34 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002368318 Vs 14:53:49 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002648309 Vs 14:54:04 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002387682 Vs 14:54:04 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002510400 +- 0.000005466 Vs 14:54:04 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.002510400 +- 0.000005466 Vs BL = 0.02510400 +- 0.00005466 Tm 14:54:04 Integrated Voltage Measurement... 14:54:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000131439 Vs 14:54:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000085616 Vs 14:54:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000098824 Vs 14:55:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000065754 Vs 14:55:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000083986 Vs 14:55:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000047617 Vs 14:55:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000064608 Vs 14:56:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000036688 Vs 14:56:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000017898 +- 0.000003263 Vs 14:56:08 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000017898 +- 0.000003263 Vs BL = 0.00017898 +- 0.00003263 Tm 14:56:08 Integrated Voltage Measurement... 14:56:27 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002448231 Vs 14:56:42 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002514857 Vs 14:56:57 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002463284 Vs 14:57:12 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002498690 Vs 14:57:27 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002471218 Vs 14:57:42 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002495179 Vs 14:57:57 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002477326 Vs 14:58:12 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002486011 Vs 14:58:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002481849 +- 0.000000820 Vs 14:58:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002481849 +- 0.000000820 Vs BL = -0.02481849 +- 0.00000820 Tm 14:58:13 Integrated Voltage Measurement... 14:58:31 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.004976425 Vs 14:58:46 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.004981349 Vs 14:59:01 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.004990258 Vs 14:59:16 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.004960354 Vs 14:59:31 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005012775 Vs 14:59:46 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.004941803 Vs 15:00:01 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005021903 Vs 15:00:16 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.004945899 Vs 15:00:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.004978846 +- 0.000003183 Vs 15:00:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004978846 +- 0.000003183 Vs BL = -0.04978846 +- 0.00003183 Tm 15:00:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00016 0.00001 1 -2.49746 0.00092 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 0.05012 0.00002 0.05011 0.00001 -0.010000 0.02510 0.00005 0.02513 -0.00003 0.000000 0.00018 0.00003 0.00016 0.00002 0.010000 -0.02482 0.00001 -0.02481 -0.00000 0.020000 -0.04979 0.00003 -0.04979 0.00000 15:00:22 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 0.05012 0.00002 -0.0100 0.02510 0.00005 0.0000 0.00018 0.00003 0.0100 -0.02482 0.00001 0.0200 -0.04979 0.00003 SL = -2.4974631 +- 0.0009178 Tm^2/m^n 15:00:22 Quadrupole Strength Calculation Check Slope = -2.497463 Tm/m, Inter = 0.000160 Tm, Sig_slope = 0.000711 Tm/m, Est_sig = 0.000022 Tm GL = -2.497463 +- 0.000711 T 15:00:22 Magnet Strength Measurement Harmonic Number = 2 SL = -2.4974631 +- 0.0009178 Tm^2/m^n 15:00:23 Magnet Current, Imag = 60.2594 A Vtrans = 0.602594 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:00:25 Magnet Current, Imag = 60.2605 A Vtrans = 0.602605 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:00:26 Magnet Current, Imag = 60.2599 A Vtrans = 0.602599 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:00:27 Magnet Current, Imag = 60.2596 A Vtrans = 0.602596 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:00:27 Magnet Current Measurement: Imag = 60.2599 +- 0.0004 A 15:00:27 Magnet current ramping to 70.0000 A... 15:00:39 Magnet Current, Imag = 70.3321 A Vtrans = 0.703321 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:00:40 Magnet Current, Imag = 70.3307 A Vtrans = 0.703307 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:00:41 Magnet Current, Imag = 70.3314 A Vtrans = 0.703314 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:00:43 Magnet Current, Imag = 70.3318 A Vtrans = 0.703318 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:00:43 Magnet Current Measurement: Imag = 70.3315 +- 0.0005 A 15:00:43 Magnetic Field Measurement Measuring the magnet strength... 15:00:43 Integrated Voltage Measurement... 15:01:05 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005788255 Vs 15:01:20 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.005836302 Vs 15:01:35 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005794138 Vs 15:01:50 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.005829991 Vs 15:02:05 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005809683 Vs 15:02:20 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.005822873 Vs 15:02:35 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005810933 Vs 15:02:50 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.005823107 Vs 15:02:50 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005814410 +- 0.000002255 Vs 15:02:50 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005814410 +- 0.000002255 Vs BL = 0.05814410 +- 0.00002255 Tm 15:02:50 Integrated Voltage Measurement... 15:03:09 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002912257 Vs 15:03:24 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002918758 Vs 15:03:39 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002908954 Vs 15:03:54 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002915191 Vs 15:04:09 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002919555 Vs 15:04:24 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002917873 Vs 15:04:39 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002918911 Vs 15:04:54 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002916070 Vs 15:04:54 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002915946 +- 0.000002512 Vs 15:04:54 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.002915946 +- 0.000002512 Vs BL = 0.02915946 +- 0.00002512 Tm 15:04:55 Integrated Voltage Measurement... 15:05:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000015825 Vs 15:05:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000017025 Vs 15:05:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000022664 Vs 15:05:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000010591 Vs 15:06:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000019353 Vs 15:06:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000010164 Vs 15:06:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000026567 Vs 15:06:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000003221 Vs 15:06:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000015676 +- 0.000000854 Vs 15:06:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000015676 +- 0.000000854 Vs BL = 0.00015676 +- 0.00000854 Tm 15:06:59 Integrated Voltage Measurement... 15:07:17 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002874335 Vs 15:07:32 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002888796 Vs 15:07:47 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002874807 Vs 15:08:03 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002892588 Vs 15:08:18 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002873534 Vs 15:08:33 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002891313 Vs 15:08:48 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002879073 Vs 15:09:03 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002892634 Vs 15:09:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002883385 +- 0.000001615 Vs 15:09:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002883385 +- 0.000001615 Vs BL = -0.02883385 +- 0.00001615 Tm 15:09:03 Integrated Voltage Measurement... 15:09:21 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005779749 Vs 15:09:36 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005781877 Vs 15:09:51 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005781022 Vs 15:10:06 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005785660 Vs 15:10:21 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005771530 Vs 15:10:36 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005793012 Vs 15:10:52 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005757422 Vs 15:11:07 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005804315 Vs 15:11:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005781823 +- 0.000001053 Vs 15:11:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005781823 +- 0.000001053 Vs BL = -0.05781823 +- 0.00001053 Tm 15:11:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00016 0.00001 1 -2.89918 0.00058 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 0.05814 0.00002 0.05815 -0.00000 -0.010000 0.02916 0.00003 0.02915 0.00001 0.000000 0.00016 0.00001 0.00016 -0.00000 0.010000 -0.02883 0.00002 -0.02883 -0.00000 0.020000 -0.05782 0.00001 -0.05782 0.00000 15:11:12 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 0.05814 0.00002 -0.0100 0.02916 0.00003 0.0000 0.00016 0.00001 0.0100 -0.02883 0.00002 0.0200 -0.05782 0.00001 SL = -2.8991798 +- 0.0005805 Tm^2/m^n 15:11:12 Quadrupole Strength Calculation Check Slope = -2.899180 Tm/m, Inter = 0.000162 Tm, Sig_slope = 0.000172 Tm/m, Est_sig = 0.000005 Tm GL = -2.899180 +- 0.000172 T 15:11:12 Magnet Strength Measurement Harmonic Number = 2 SL = -2.8991798 +- 0.0005805 Tm^2/m^n 15:11:13 Magnet Current, Imag = 70.3333 A Vtrans = 0.703333 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:11:15 Magnet Current, Imag = 70.3336 A Vtrans = 0.703336 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:11:16 Magnet Current, Imag = 70.3336 A Vtrans = 0.703336 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:11:17 Magnet Current, Imag = 70.3339 A Vtrans = 0.703339 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:11:17 Magnet Current Measurement: Imag = 70.3336 +- 0.0002 A 15:11:17 Magnet current ramping to 80.0000 A... 15:11:29 Magnet Current, Imag = 80.4629 A Vtrans = 0.804629 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:11:30 Magnet Current, Imag = 80.4636 A Vtrans = 0.804636 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:11:31 Magnet Current, Imag = 80.4625 A Vtrans = 0.804625 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:11:33 Magnet Current, Imag = 80.4627 A Vtrans = 0.804627 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:11:33 Magnet Current Measurement: Imag = 80.4629 +- 0.0004 A 15:11:33 Magnetic Field Measurement Measuring the magnet strength... 15:11:33 Integrated Voltage Measurement... 15:11:55 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006551654 Vs 15:12:10 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006495275 Vs 15:12:25 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006557196 Vs 15:12:40 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006500040 Vs 15:12:55 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006556641 Vs 15:13:10 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006496452 Vs 15:13:25 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006559660 Vs 15:13:40 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006492637 Vs 15:13:40 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006526194 +- 0.000001834 Vs 15:13:40 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.006526194 +- 0.000001834 Vs BL = 0.06526194 +- 0.00001834 Tm 15:13:40 Integrated Voltage Measurement... 15:13:59 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003304872 Vs 15:14:14 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003244493 Vs 15:14:29 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003302240 Vs 15:14:44 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003243633 Vs 15:14:59 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003294347 Vs 15:15:14 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003264361 Vs 15:15:29 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003293418 Vs 15:15:44 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003258875 Vs 15:15:44 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003275780 +- 0.000002356 Vs 15:15:44 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003275780 +- 0.000002356 Vs BL = 0.03275780 +- 0.00002356 Tm 15:15:44 Integrated Voltage Measurement... 15:16:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000036237 Vs 15:16:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000006478 Vs 15:16:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000036604 Vs 15:16:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000003651 Vs 15:17:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000032685 Vs 15:17:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000007219 Vs 15:17:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000037076 Vs 15:17:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000005940 Vs 15:17:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000020736 +- 0.000000701 Vs 15:17:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000020736 +- 0.000000701 Vs BL = 0.00020736 +- 0.00000701 Tm 15:17:48 Integrated Voltage Measurement... 15:18:07 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003219489 Vs 15:18:22 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003247490 Vs 15:18:37 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003221240 Vs 15:18:52 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003248856 Vs 15:19:07 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003217195 Vs 15:19:22 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003250331 Vs 15:19:37 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003219864 Vs 15:19:52 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003251549 Vs 15:19:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003234502 +- 0.000000911 Vs 15:19:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003234502 +- 0.000000911 Vs BL = -0.03234502 +- 0.00000911 Tm 15:19:52 Integrated Voltage Measurement... 15:20:11 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.006468093 Vs 15:20:26 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.006501258 Vs 15:20:41 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.006468213 Vs 15:20:56 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.006495107 Vs 15:21:11 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.006480605 Vs 15:21:26 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.006490480 Vs 15:21:41 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.006491993 Vs 15:21:56 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.006487732 Vs 15:21:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.006485435 +- 0.000002934 Vs 15:21:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006485435 +- 0.000002934 Vs BL = -0.06485435 +- 0.00002934 Tm 15:22:01 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00021 0.00001 1 -3.25335 0.00074 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 0.06526 0.00002 0.06527 -0.00001 -0.010000 0.03276 0.00002 0.03274 0.00002 0.000000 0.00021 0.00001 0.00021 0.00000 0.010000 -0.03235 0.00001 -0.03233 -0.00002 0.020000 -0.06485 0.00003 -0.06486 0.00001 15:22:01 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 0.06526 0.00002 -0.0100 0.03276 0.00002 0.0000 0.00021 0.00001 0.0100 -0.03235 0.00001 0.0200 -0.06485 0.00003 SL = -3.2533541 +- 0.0007367 Tm^2/m^n 15:22:02 Quadrupole Strength Calculation Check Slope = -3.253354 Tm/m, Inter = 0.000206 Tm, Sig_slope = 0.000519 Tm/m, Est_sig = 0.000016 Tm GL = -3.253354 +- 0.000519 T 15:22:02 Magnet Strength Measurement Harmonic Number = 2 SL = -3.2533541 +- 0.0007367 Tm^2/m^n 15:22:03 Magnet Current, Imag = 80.4654 A Vtrans = 0.804654 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:22:04 Magnet Current, Imag = 80.4644 A Vtrans = 0.804644 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:22:05 Magnet Current, Imag = 80.4644 A Vtrans = 0.804644 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:22:07 Magnet Current, Imag = 80.4653 A Vtrans = 0.804653 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:22:07 Magnet Current Measurement: Imag = 80.4649 +- 0.0005 A 15:22:07 Magnet current ramping to 90.0000 A... 15:22:18 Magnet Current, Imag = 90.5027 A Vtrans = 0.905027 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:22:20 Magnet Current, Imag = 90.5034 A Vtrans = 0.905034 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:22:21 Magnet Current, Imag = 90.5024 A Vtrans = 0.905024 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:22:22 Magnet Current, Imag = 90.5022 A Vtrans = 0.905022 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:22:22 Magnet Current Measurement: Imag = 90.5027 +- 0.0005 A 15:22:22 Magnetic Field Measurement Measuring the magnet strength... 15:22:22 Integrated Voltage Measurement... 15:22:45 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.007055499 Vs 15:23:00 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.007053722 Vs 15:23:15 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.007060528 Vs 15:23:30 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.007058477 Vs 15:23:45 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.007058466 Vs 15:24:00 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.007062946 Vs 15:24:15 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.007055447 Vs 15:24:30 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.007066132 Vs 15:24:30 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.007058902 +- 0.000002530 Vs 15:24:30 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.007058902 +- 0.000002530 Vs BL = 0.07058902 +- 0.00002530 Tm 15:24:30 Integrated Voltage Measurement... 15:24:49 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003546687 Vs 15:25:04 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003545160 Vs 15:25:19 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003527923 Vs 15:25:35 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003548424 Vs 15:25:50 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003529258 Vs 15:26:05 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003552848 Vs 15:26:20 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003524818 Vs 15:26:35 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003545352 Vs 15:26:35 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003540059 +- 0.000003990 Vs 15:26:35 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003540059 +- 0.000003990 Vs BL = 0.03540059 +- 0.00003990 Tm 15:26:35 Integrated Voltage Measurement... 15:26:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000015549 Vs 15:27:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000023677 Vs 15:27:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000020637 Vs 15:27:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000032134 Vs 15:27:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000010585 Vs 15:28:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000028460 Vs 15:28:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000010292 Vs 15:28:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000031449 Vs 15:28:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000021598 +- 0.000002815 Vs 15:28:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000021598 +- 0.000002815 Vs BL = 0.00021598 +- 0.00002815 Tm 15:28:39 Integrated Voltage Measurement... 15:28:58 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003508793 Vs 15:29:13 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003489210 Vs 15:29:28 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003512623 Vs 15:29:43 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003475398 Vs 15:29:58 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003506042 Vs 15:30:13 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003483813 Vs 15:30:28 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003514214 Vs 15:30:44 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003481948 Vs 15:30:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003496505 +- 0.000002087 Vs 15:30:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003496505 +- 0.000002087 Vs BL = -0.03496505 +- 0.00002087 Tm 15:30:44 Integrated Voltage Measurement... 15:31:02 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.007029729 Vs 15:31:17 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.006998058 Vs 15:31:32 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.007026337 Vs 15:31:47 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.007007245 Vs 15:32:02 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.007024570 Vs 15:32:17 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.007006436 Vs 15:32:32 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.007017973 Vs 15:32:47 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.007007222 Vs 15:32:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.007014696 +- 0.000001588 Vs 15:32:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.007014696 +- 0.000001588 Vs BL = -0.07014696 +- 0.00001588 Tm 15:32:53 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00022 0.00001 1 -3.51838 0.00075 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 0.07059 0.00003 0.07059 0.00000 -0.010000 0.03540 0.00004 0.03540 -0.00000 0.000000 0.00022 0.00003 0.00022 -0.00000 0.010000 -0.03497 0.00002 -0.03497 -0.00000 0.020000 -0.07015 0.00002 -0.07015 0.00000 15:32:53 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 0.07059 0.00003 -0.0100 0.03540 0.00004 0.0000 0.00022 0.00003 0.0100 -0.03497 0.00002 0.0200 -0.07015 0.00002 SL = -3.5183761 +- 0.0007481 Tm^2/m^n 15:32:53 Quadrupole Strength Calculation Check Slope = -3.518376 Tm/m, Inter = 0.000219 Tm, Sig_slope = 0.000086 Tm/m, Est_sig = 0.000003 Tm GL = -3.518376 +- 0.000086 T 15:32:53 Magnet Strength Measurement Harmonic Number = 2 SL = -3.5183761 +- 0.0007481 Tm^2/m^n 15:32:54 Magnet Current, Imag = 90.5051 A Vtrans = 0.905051 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:55 Magnet Current, Imag = 90.5047 A Vtrans = 0.905047 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:57 Magnet Current, Imag = 90.5063 A Vtrans = 0.905063 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:58 Magnet Current, Imag = 90.5057 A Vtrans = 0.905057 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:58 Magnet Current Measurement: Imag = 90.5054 +- 0.0006 A 15:32:59 Magnet current ramping to 0.0000 A...