SLAC Magnetic Measurements Date: 12-04-2003 Time: 15:01:04 Project: spear3 Magnet Type: quad Magnet Name: 34Q-047_cross_talk Serial Number: Run Number: 13 Measurement Device: 10 wire Operator: sa Comment: Corrector no shield 95 mm shield to quad distance, 103.2 mm Corr Yoke to Quad Dist. Int Str vs I. Standardization: 3 cycles from 0.0 A to 98.0 A to 0.0 A Test Currents (A): 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 15:01:18 Initial Zero Current Measurement, Imag_zero = 0.0000 A 15:01:18 Magnet current ramping to 15.0000 A... 15:02:14 Magnet current ramping to 98.0000 A... 15:03:09 Magnet current ramping to 0.0000 A... 15:04:08 Magnet current ramping to 98.0000 A... 15:05:07 Magnet current ramping to 0.0000 A... 15:06:07 Magnet current ramping to 98.0000 A... 15:07:07 Magnet current ramping to 0.0000 A... 15:08:06 Magnet current ramping to 10.0000 A... 15:08:42 Magnet Current, Imag = 10.0031 A Vtrans = 0.800249 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:08:43 Magnet Current, Imag = 10.0028 A Vtrans = 0.800220 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:08:44 Magnet Current, Imag = 10.0033 A Vtrans = 0.800265 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:08:46 Magnet Current, Imag = 10.0027 A Vtrans = 0.800216 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:08:46 Magnet Current Measurement: Imag = 10.0030 +- 0.0003 A 15:08:46 Magnetic Field Measurement Measuring the magnet strength... 15:08:46 Integrated Voltage Measurement... 15:09:04 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.001849363 Vs 15:09:13 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.001832551 Vs 15:09:21 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.001850069 Vs 15:09:30 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.001828811 Vs 15:09:38 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.001850038 Vs 15:09:47 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.001830444 Vs 15:09:56 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.001851629 Vs 15:10:04 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.001833054 Vs 15:10:04 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.001840745 +- 0.000001066 Vs 15:10:04 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001840745 +- 0.000001066 Vs BL = -0.01840745 +- 0.00001066 Tm 15:10:04 Integrated Voltage Measurement... 15:10:19 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.000947386 Vs 15:10:27 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.000934087 Vs 15:10:36 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.000942859 Vs 15:10:45 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.000932979 Vs 15:10:53 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.000945583 Vs 15:11:02 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.000929748 Vs 15:11:10 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.000937165 Vs 15:11:19 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.000938855 Vs 15:11:19 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.000938583 +- 0.000001250 Vs 15:11:19 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000938583 +- 0.000001250 Vs BL = -0.00938583 +- 0.00001250 Tm 15:11:19 Integrated Voltage Measurement... 15:11:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000029614 Vs 15:11:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000040911 Vs 15:11:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000027939 Vs 15:12:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000050648 Vs 15:12:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000026045 Vs 15:12:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000049629 Vs 15:12:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000021262 Vs 15:12:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000052765 Vs 15:12:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000037352 +- 0.000001457 Vs 15:12:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000037352 +- 0.000001457 Vs BL = -0.00037352 +- 0.00001457 Tm 15:12:34 Integrated Voltage Measurement... 15:12:49 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.000883243 Vs 15:12:57 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.000842320 Vs 15:13:06 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.000882754 Vs 15:13:15 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.000838274 Vs 15:13:23 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.000885770 Vs 15:13:32 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.000831040 Vs 15:13:40 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.000892826 Vs 15:13:49 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.000835292 Vs 15:13:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.000861440 +- 0.000002164 Vs 15:13:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000861440 +- 0.000002164 Vs BL = 0.00861440 +- 0.00002164 Tm 15:13:49 Integrated Voltage Measurement... 15:14:04 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.001793272 Vs 15:14:12 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.001735792 Vs 15:14:21 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.001790333 Vs 15:14:29 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.001737266 Vs 15:14:38 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.001791249 Vs 15:14:47 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.001739668 Vs 15:14:55 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.001790941 Vs 15:15:04 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.001741700 Vs 15:15:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.001765028 +- 0.000000950 Vs 15:15:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.001765028 +- 0.000000950 Vs BL = 0.01765028 +- 0.00000950 Tm 15:15:11 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00038 0.00001 1 0.90116 0.00038 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 -0.01841 0.00001 -0.01840 -0.00000 -0.010000 -0.00939 0.00001 -0.00939 0.00001 0.000000 -0.00037 0.00001 -0.00038 0.00001 0.010000 0.00861 0.00002 0.00863 -0.00002 0.020000 0.01765 0.00001 0.01764 0.00001 15:15:11 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 -0.01841 0.00001 -0.0100 -0.00939 0.00001 0.0000 -0.00037 0.00001 0.0100 0.00861 0.00002 0.0200 0.01765 0.00001 SL = 0.9011567 +- 0.0003795 Tm^2/m^n 15:15:11 Quadrupole Strength Calculation Check Slope = 0.901157 Tm/m, Inter = -0.000380 Tm, Sig_slope = 0.000382 Tm/m, Est_sig = 0.000012 Tm GL = 0.901157 +- 0.000382 T 15:15:11 Magnet Strength Measurement Harmonic Number = 2 SL = 0.9011567 +- 0.0003795 Tm^2/m^n 15:15:12 Magnet Current, Imag = 10.0020 A Vtrans = 0.800159 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:15:14 Magnet Current, Imag = 10.0020 A Vtrans = 0.800162 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:15:15 Magnet Current, Imag = 10.0015 A Vtrans = 0.800124 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:15:16 Magnet Current, Imag = 10.0022 A Vtrans = 0.800174 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:15:16 Magnet Current Measurement: Imag = 10.0019 +- 0.0002 A 15:15:16 Magnet current ramping to 20.0000 A... 15:15:52 Magnet Current, Imag = 20.0657 A Vtrans = 1.605255 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:15:53 Magnet Current, Imag = 20.0656 A Vtrans = 1.605251 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:15:54 Magnet Current, Imag = 20.0654 A Vtrans = 1.605234 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:15:55 Magnet Current, Imag = 20.0654 A Vtrans = 1.605230 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:15:55 Magnet Current Measurement: Imag = 20.0655 +- 0.0001 A 15:15:55 Magnetic Field Measurement Measuring the magnet strength... 15:15:55 Integrated Voltage Measurement... 15:16:14 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.003652143 Vs 15:16:22 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.003691716 Vs 15:16:31 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.003650933 Vs 15:16:39 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.003690054 Vs 15:16:48 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.003647138 Vs 15:16:57 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.003695498 Vs 15:17:05 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.003645382 Vs 15:17:14 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.003700478 Vs 15:17:14 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.003671668 +- 0.000000889 Vs 15:17:14 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003671668 +- 0.000000889 Vs BL = -0.03671668 +- 0.00000889 Tm 15:17:14 Integrated Voltage Measurement... 15:17:28 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.001837415 Vs 15:17:37 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.001890556 Vs 15:17:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.001844348 Vs 15:17:54 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.001898348 Vs 15:18:03 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.001839797 Vs 15:18:11 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.001901062 Vs 15:18:20 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.001839407 Vs 15:18:29 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.001898222 Vs 15:18:29 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.001868644 +- 0.000002838 Vs 15:18:29 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001868644 +- 0.000002838 Vs BL = -0.01868644 +- 0.00002838 Tm 15:18:29 Integrated Voltage Measurement... 15:18:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000037155 Vs 15:18:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000095364 Vs 15:19:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000039985 Vs 15:19:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000095007 Vs 15:19:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000035775 Vs 15:19:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000094906 Vs 15:19:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000039391 Vs 15:19:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000099720 Vs 15:19:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000067163 +- 0.000001579 Vs 15:19:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000067163 +- 0.000001579 Vs BL = -0.00067163 +- 0.00001579 Tm 15:19:43 Integrated Voltage Measurement... 15:19:58 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.001755484 Vs 15:20:06 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.001708579 Vs 15:20:15 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.001759990 Vs 15:20:24 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.001710112 Vs 15:20:32 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.001754573 Vs 15:20:41 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.001713991 Vs 15:20:49 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.001749882 Vs 15:20:58 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.001718336 Vs 15:20:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.001733868 +- 0.000001118 Vs 15:20:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.001733868 +- 0.000001118 Vs BL = 0.01733868 +- 0.00001118 Tm 15:20:58 Integrated Voltage Measurement... 15:21:13 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.003547420 Vs 15:21:21 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.003518371 Vs 15:21:30 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.003539536 Vs 15:21:38 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.003521127 Vs 15:21:47 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.003540401 Vs 15:21:56 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.003514753 Vs 15:22:04 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.003544380 Vs 15:22:13 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.003520699 Vs 15:22:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.003530836 +- 0.000002122 Vs 15:22:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003530836 +- 0.000002122 Vs BL = 0.03530836 +- 0.00002122 Tm 15:22:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00069 0.00001 1 1.80075 0.00055 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 -0.03672 0.00001 -0.03670 -0.00002 -0.010000 -0.01869 0.00003 -0.01869 0.00001 0.000000 -0.00067 0.00002 -0.00069 0.00001 0.010000 0.01734 0.00001 0.01732 0.00002 0.020000 0.03531 0.00002 0.03533 -0.00002 15:22:20 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 -0.03672 0.00001 -0.0100 -0.01869 0.00003 0.0000 -0.00067 0.00002 0.0100 0.01734 0.00001 0.0200 0.03531 0.00002 SL = 1.8007520 +- 0.0005522 Tm^2/m^n 15:22:20 Quadrupole Strength Calculation Check Slope = 1.800752 Tm/m, Inter = -0.000686 Tm, Sig_slope = 0.000638 Tm/m, Est_sig = 0.000020 Tm GL = 1.800752 +- 0.000638 T 15:22:20 Magnet Strength Measurement Harmonic Number = 2 SL = 1.8007520 +- 0.0005522 Tm^2/m^n 15:22:21 Magnet Current, Imag = 20.0646 A Vtrans = 1.605168 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:22:23 Magnet Current, Imag = 20.0641 A Vtrans = 1.605130 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:22:24 Magnet Current, Imag = 20.0641 A Vtrans = 1.605125 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:22:25 Magnet Current, Imag = 20.0642 A Vtrans = 1.605137 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:22:25 Magnet Current Measurement: Imag = 20.0643 +- 0.0002 A 15:22:25 Magnet current ramping to 30.0000 A... 15:23:01 Magnet Current, Imag = 30.1323 A Vtrans = 2.410585 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:23:02 Magnet Current, Imag = 30.1325 A Vtrans = 2.410600 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:23:03 Magnet Current, Imag = 30.1321 A Vtrans = 2.410568 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:23:04 Magnet Current, Imag = 30.1324 A Vtrans = 2.410594 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:23:04 Magnet Current Measurement: Imag = 30.1323 +- 0.0002 A 15:23:04 Magnetic Field Measurement Measuring the magnet strength... 15:23:04 Integrated Voltage Measurement... 15:23:23 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005487462 Vs 15:23:31 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.005521245 Vs 15:23:40 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005493843 Vs 15:23:48 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.005524155 Vs 15:23:57 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005492156 Vs 15:24:06 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.005522425 Vs 15:24:14 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005497511 Vs 15:24:23 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.005514159 Vs 15:24:23 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005506619 +- 0.000001722 Vs 15:24:23 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005506619 +- 0.000001722 Vs BL = -0.05506619 +- 0.00001722 Tm 15:24:23 Integrated Voltage Measurement... 15:24:37 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002796735 Vs 15:24:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.002804435 Vs 15:24:54 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002801683 Vs 15:25:03 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.002807343 Vs 15:25:12 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002801571 Vs 15:25:20 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.002803899 Vs 15:25:29 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002805941 Vs 15:25:37 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.002804202 Vs 15:25:38 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002803226 +- 0.000001752 Vs 15:25:38 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002803226 +- 0.000001752 Vs BL = -0.02803226 +- 0.00001752 Tm 15:25:38 Integrated Voltage Measurement... 15:25:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000096050 Vs 15:26:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000106012 Vs 15:26:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000091711 Vs 15:26:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000112473 Vs 15:26:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000088154 Vs 15:26:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000114271 Vs 15:26:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000084109 Vs 15:26:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000114785 Vs 15:26:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000100946 +- 0.000000954 Vs 15:26:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000100946 +- 0.000000954 Vs BL = -0.00100946 +- 0.00000954 Tm 15:26:52 Integrated Voltage Measurement... 15:27:07 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.002619666 Vs 15:27:15 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.002590853 Vs 15:27:24 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.002617493 Vs 15:27:33 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.002595957 Vs 15:27:41 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.002614793 Vs 15:27:50 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.002595192 Vs 15:27:58 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.002604129 Vs 15:28:07 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.002611817 Vs 15:28:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.002606237 +- 0.000001200 Vs 15:28:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.002606237 +- 0.000001200 Vs BL = 0.02606237 +- 0.00001200 Tm 15:28:07 Integrated Voltage Measurement... 15:28:21 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.005289843 Vs 15:28:30 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.005322513 Vs 15:28:39 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.005287344 Vs 15:28:47 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.005333836 Vs 15:28:56 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.005273231 Vs 15:29:05 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.005351137 Vs 15:29:13 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.005259375 Vs 15:29:22 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.005353959 Vs 15:29:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.005308905 +- 0.000002551 Vs 15:29:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005308905 +- 0.000002551 Vs BL = 0.05308905 +- 0.00002551 Tm 15:29:29 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00099 0.00001 1 2.70405 0.00065 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 -0.05507 0.00002 -0.05507 0.00001 -0.010000 -0.02803 0.00002 -0.02803 -0.00000 0.000000 -0.00101 0.00001 -0.00099 -0.00002 0.010000 0.02606 0.00001 0.02605 0.00001 0.020000 0.05309 0.00003 0.05309 -0.00000 15:29:29 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 -0.05507 0.00002 -0.0100 -0.02803 0.00002 0.0000 -0.00101 0.00001 0.0100 0.02606 0.00001 0.0200 0.05309 0.00003 SL = 2.7040512 +- 0.0006512 Tm^2/m^n 15:29:29 Quadrupole Strength Calculation Check Slope = 2.704051 Tm/m, Inter = -0.000991 Tm, Sig_slope = 0.000425 Tm/m, Est_sig = 0.000013 Tm GL = 2.704051 +- 0.000425 T 15:29:29 Magnet Strength Measurement Harmonic Number = 2 SL = 2.7040512 +- 0.0006512 Tm^2/m^n 15:29:30 Magnet Current, Imag = 30.1338 A Vtrans = 2.410705 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:29:32 Magnet Current, Imag = 30.1336 A Vtrans = 2.410686 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:29:33 Magnet Current, Imag = 30.1346 A Vtrans = 2.410767 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:29:34 Magnet Current, Imag = 30.1341 A Vtrans = 2.410726 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:29:34 Magnet Current Measurement: Imag = 30.1340 +- 0.0004 A 15:29:34 Magnet current ramping to 40.0000 A... 15:30:10 Magnet Current, Imag = 40.2182 A Vtrans = 3.217460 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:30:12 Magnet Current, Imag = 40.2185 A Vtrans = 3.217480 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:30:13 Magnet Current, Imag = 40.2190 A Vtrans = 3.217520 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:30:15 Magnet Current, Imag = 40.2188 A Vtrans = 3.217500 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:30:15 Magnet Current Measurement: Imag = 40.2186 +- 0.0003 A 15:30:15 Magnetic Field Measurement Measuring the magnet strength... 15:30:15 Integrated Voltage Measurement... 15:30:33 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.007421585 Vs 15:30:42 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.007268336 Vs 15:30:51 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.007426990 Vs 15:30:59 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.007262852 Vs 15:31:08 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.007430687 Vs 15:31:16 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.007256879 Vs 15:31:25 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.007442016 Vs 15:31:34 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.007268138 Vs 15:31:34 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.007347185 +- 0.000004581 Vs 15:31:34 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.007347185 +- 0.000004581 Vs BL = -0.07347185 +- 0.00004581 Tm 15:31:34 Integrated Voltage Measurement... 15:31:48 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.003811429 Vs 15:31:57 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.003669878 Vs 15:32:05 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.003801316 Vs 15:32:14 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.003677364 Vs 15:32:23 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.003793183 Vs 15:32:31 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.003690773 Vs 15:32:40 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.003786031 Vs 15:32:48 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.003697000 Vs 15:32:48 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.003740872 +- 0.000001004 Vs 15:32:49 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003740872 +- 0.000001004 Vs BL = -0.03740872 +- 0.00001004 Tm 15:32:49 Integrated Voltage Measurement... 15:33:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000179641 Vs 15:33:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000085101 Vs 15:33:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000179555 Vs 15:33:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000083832 Vs 15:33:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000179900 Vs 15:33:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000073330 Vs 15:33:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000189034 Vs 15:34:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000077180 Vs 15:34:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000130946 +- 0.000002550 Vs 15:34:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000130946 +- 0.000002550 Vs BL = -0.00130946 +- 0.00002550 Tm 15:34:03 Integrated Voltage Measurement... 15:34:18 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003427711 Vs 15:34:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.003527702 Vs 15:34:35 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003427858 Vs 15:34:43 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.003524439 Vs 15:34:52 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003428407 Vs 15:35:01 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.003523792 Vs 15:35:09 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003431423 Vs 15:35:18 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.003525196 Vs 15:35:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003477066 +- 0.000000966 Vs 15:35:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003477066 +- 0.000000966 Vs BL = 0.03477066 +- 0.00000966 Tm 15:35:18 Integrated Voltage Measurement... 15:35:32 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.007024453 Vs 15:35:41 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.007140058 Vs 15:35:50 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.007021840 Vs 15:35:58 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.007141116 Vs 15:36:07 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.007022223 Vs 15:36:15 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.007139473 Vs 15:36:24 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.007026687 Vs 15:36:33 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.007133907 Vs 15:36:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.007081220 +- 0.000000730 Vs 15:36:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.007081220 +- 0.000000730 Vs BL = 0.07081220 +- 0.00000730 Tm 15:36:40 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00132 0.00001 1 3.60747 0.00094 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 -0.07347 0.00005 -0.07347 -0.00000 -0.010000 -0.03741 0.00001 -0.03740 -0.00001 0.000000 -0.00131 0.00003 -0.00132 0.00001 0.010000 0.03477 0.00001 0.03475 0.00002 0.020000 0.07081 0.00001 0.07083 -0.00002 15:36:40 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 -0.07347 0.00005 -0.0100 -0.03741 0.00001 0.0000 -0.00131 0.00003 0.0100 0.03477 0.00001 0.0200 0.07081 0.00001 SL = 3.6074748 +- 0.0009381 Tm^2/m^n 15:36:40 Quadrupole Strength Calculation Check Slope = 3.607475 Tm/m, Inter = -0.001321 Tm, Sig_slope = 0.000534 Tm/m, Est_sig = 0.000017 Tm GL = 3.607475 +- 0.000534 T 15:36:40 Magnet Strength Measurement Harmonic Number = 2 SL = 3.6074748 +- 0.0009381 Tm^2/m^n 15:36:42 Magnet Current, Imag = 40.2193 A Vtrans = 3.217540 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:36:43 Magnet Current, Imag = 40.2186 A Vtrans = 3.217490 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:36:45 Magnet Current, Imag = 40.2185 A Vtrans = 3.217480 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:36:47 Magnet Current, Imag = 40.2185 A Vtrans = 3.217480 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:36:47 Magnet Current Measurement: Imag = 40.2187 +- 0.0003 A 15:36:47 Magnet current ramping to 50.0000 A... 15:37:23 Magnet Current, Imag = 50.3576 A Vtrans = 4.028610 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:37:24 Magnet Current, Imag = 50.3571 A Vtrans = 4.028570 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:37:26 Magnet Current, Imag = 50.3571 A Vtrans = 4.028570 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:37:27 Magnet Current, Imag = 50.3578 A Vtrans = 4.028620 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:37:27 Magnet Current Measurement: Imag = 50.3574 +- 0.0003 A 15:37:27 Magnetic Field Measurement Measuring the magnet strength... 15:37:27 Integrated Voltage Measurement... 15:37:45 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.009225657 Vs 15:37:54 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.009159674 Vs 15:38:03 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.009222773 Vs 15:38:11 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.009156041 Vs 15:38:20 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.009221558 Vs 15:38:28 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.009162906 Vs 15:38:37 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.009218540 Vs 15:38:46 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.009165676 Vs 15:38:46 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.009191603 +- 0.000001285 Vs 15:38:46 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.009191603 +- 0.000001285 Vs BL = -0.09191603 +- 0.00001285 Tm 15:38:46 Integrated Voltage Measurement... 15:39:00 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.004705772 Vs 15:39:09 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.004645107 Vs 15:39:17 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.004706400 Vs 15:39:26 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.004651584 Vs 15:39:35 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.004699466 Vs 15:39:43 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.004651328 Vs 15:39:52 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.004699853 Vs 15:40:00 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.004652391 Vs 15:40:00 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.004676488 +- 0.000001474 Vs 15:40:00 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004676488 +- 0.000001474 Vs BL = -0.04676488 +- 0.00001474 Tm 15:40:00 Integrated Voltage Measurement... 15:40:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000183993 Vs 15:40:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000144206 Vs 15:40:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000178114 Vs 15:40:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000140792 Vs 15:40:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000179652 Vs 15:40:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000145128 Vs 15:41:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000176867 Vs 15:41:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000146814 Vs 15:41:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000161946 +- 0.000001663 Vs 15:41:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000161946 +- 0.000001663 Vs BL = -0.00161946 +- 0.00001663 Tm 15:41:15 Integrated Voltage Measurement... 15:41:30 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.004335054 Vs 15:41:38 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.004369730 Vs 15:41:47 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.004338380 Vs 15:41:55 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.004362263 Vs 15:42:04 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.004337657 Vs 15:42:13 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.004373713 Vs 15:42:21 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.004325668 Vs 15:42:30 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.004374765 Vs 15:42:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.004352154 +- 0.000002216 Vs 15:42:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.004352154 +- 0.000002216 Vs BL = 0.04352154 +- 0.00002216 Tm 15:42:30 Integrated Voltage Measurement... 15:42:44 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.008846557 Vs 15:42:53 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.008872891 Vs 15:43:02 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.008845100 Vs 15:43:10 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.008872681 Vs 15:43:19 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.008852191 Vs 15:43:27 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.008869073 Vs 15:43:36 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.008852629 Vs 15:43:45 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.008873056 Vs 15:43:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.008860522 +- 0.000001475 Vs 15:43:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.008860522 +- 0.000001475 Vs BL = 0.08860522 +- 0.00001475 Tm 15:43:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00163 0.00001 1 4.51329 0.00047 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 -0.09192 0.00001 -0.09190 -0.00002 -0.010000 -0.04676 0.00001 -0.04677 0.00000 0.000000 -0.00162 0.00002 -0.00163 0.00002 0.010000 0.04352 0.00002 0.04350 0.00002 0.020000 0.08861 0.00001 0.08863 -0.00003 15:43:52 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 -0.09192 0.00001 -0.0100 -0.04676 0.00001 0.0000 -0.00162 0.00002 0.0100 0.04352 0.00002 0.0200 0.08861 0.00001 SL = 4.5132893 +- 0.0004731 Tm^2/m^n 15:43:52 Quadrupole Strength Calculation Check Slope = 4.513289 Tm/m, Inter = -0.001635 Tm, Sig_slope = 0.000752 Tm/m, Est_sig = 0.000024 Tm GL = 4.513289 +- 0.000752 T 15:43:52 Magnet Strength Measurement Harmonic Number = 2 SL = 4.5132893 +- 0.0004731 Tm^2/m^n 15:43:53 Magnet Current, Imag = 50.3584 A Vtrans = 4.028670 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:43:55 Magnet Current, Imag = 50.3575 A Vtrans = 4.028600 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:43:56 Magnet Current, Imag = 50.3584 A Vtrans = 4.028670 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:43:57 Magnet Current, Imag = 50.3578 A Vtrans = 4.028620 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:43:57 Magnet Current Measurement: Imag = 50.3580 +- 0.0004 A 15:43:58 Magnet current ramping to 60.0000 A... 15:44:33 Magnet Current, Imag = 60.3920 A Vtrans = 4.831360 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:44:34 Magnet Current, Imag = 60.3907 A Vtrans = 4.831260 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:44:36 Magnet Current, Imag = 60.3916 A Vtrans = 4.831330 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:44:37 Magnet Current, Imag = 60.3904 A Vtrans = 4.831230 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:44:37 Magnet Current Measurement: Imag = 60.3912 +- 0.0007 A 15:44:37 Magnetic Field Measurement Measuring the magnet strength... 15:44:37 Integrated Voltage Measurement... 15:44:55 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.011019416 Vs 15:45:04 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.011008656 Vs 15:45:13 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.011020261 Vs 15:45:21 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.011006370 Vs 15:45:30 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.011019407 Vs 15:45:39 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.011002667 Vs 15:45:47 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.011010650 Vs 15:45:56 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.011004643 Vs 15:45:56 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.011011509 +- 0.000002490 Vs 15:45:56 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.011011509 +- 0.000002490 Vs BL = -0.11011509 +- 0.00002490 Tm 15:45:56 Integrated Voltage Measurement... 15:46:10 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.005613302 Vs 15:46:19 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.005588701 Vs 15:46:27 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.005614319 Vs 15:46:36 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.005591846 Vs 15:46:45 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.005610963 Vs 15:46:53 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.005585033 Vs 15:47:02 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.005618218 Vs 15:47:10 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.005583157 Vs 15:47:11 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.005600692 +- 0.000001807 Vs 15:47:11 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005600692 +- 0.000001807 Vs BL = -0.05600692 +- 0.00001807 Tm 15:47:11 Integrated Voltage Measurement... 15:47:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000215233 Vs 15:47:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000176156 Vs 15:47:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000209960 Vs 15:47:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000174710 Vs 15:47:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000207573 Vs 15:48:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000173525 Vs 15:48:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000211347 Vs 15:48:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000166052 Vs 15:48:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000191819 +- 0.000002580 Vs 15:48:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000191819 +- 0.000002580 Vs BL = -0.00191819 +- 0.00002580 Tm 15:48:25 Integrated Voltage Measurement... 15:48:40 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.005184645 Vs 15:48:48 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.005245122 Vs 15:48:57 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.005183259 Vs 15:49:06 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.005242185 Vs 15:49:14 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.005182626 Vs 15:49:23 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.005258167 Vs 15:49:31 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.005165451 Vs 15:49:40 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.005269326 Vs 15:49:40 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.005216347 +- 0.000002862 Vs 15:49:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005216347 +- 0.000002862 Vs BL = 0.05216347 +- 0.00002862 Tm 15:49:40 Integrated Voltage Measurement... 15:49:54 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.010560977 Vs 15:50:03 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.010680757 Vs 15:50:12 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.010556580 Vs 15:50:20 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.010688742 Vs 15:50:29 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.010547473 Vs 15:50:38 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.010700536 Vs 15:50:46 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.010540638 Vs 15:50:55 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.010706373 Vs 15:50:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.010622759 +- 0.000001193 Vs 15:50:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.010622759 +- 0.000001193 Vs BL = 0.10622759 +- 0.00001193 Tm 15:51:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00193 0.00001 1 5.40856 0.00065 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 -0.11012 0.00002 -0.11010 -0.00001 -0.010000 -0.05601 0.00002 -0.05602 0.00001 0.000000 -0.00192 0.00003 -0.00193 0.00001 0.010000 0.05216 0.00003 0.05216 0.00001 0.020000 0.10623 0.00001 0.10624 -0.00001 15:51:02 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 -0.11012 0.00002 -0.0100 -0.05601 0.00002 0.0000 -0.00192 0.00003 0.0100 0.05216 0.00003 0.0200 0.10623 0.00001 SL = 5.4085576 +- 0.0006477 Tm^2/m^n 15:51:02 Quadrupole Strength Calculation Check Slope = 5.408558 Tm/m, Inter = -0.001930 Tm, Sig_slope = 0.000467 Tm/m, Est_sig = 0.000015 Tm GL = 5.408558 +- 0.000467 T 15:51:02 Magnet Strength Measurement Harmonic Number = 2 SL = 5.4085576 +- 0.0006477 Tm^2/m^n 15:51:04 Magnet Current, Imag = 60.3931 A Vtrans = 4.831450 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:51:05 Magnet Current, Imag = 60.3929 A Vtrans = 4.831430 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:51:06 Magnet Current, Imag = 60.3941 A Vtrans = 4.831530 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:51:08 Magnet Current, Imag = 60.3931 A Vtrans = 4.831450 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:51:08 Magnet Current Measurement: Imag = 60.3933 +- 0.0005 A 15:51:08 Magnet current ramping to 70.0000 A... 15:51:43 Magnet Current, Imag = 70.4594 A Vtrans = 5.636750 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:51:45 Magnet Current, Imag = 70.4599 A Vtrans = 5.636790 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:51:46 Magnet Current, Imag = 70.4595 A Vtrans = 5.636760 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:51:47 Magnet Current, Imag = 70.4596 A Vtrans = 5.636770 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:51:47 Magnet Current Measurement: Imag = 70.4596 +- 0.0002 A 15:51:47 Magnetic Field Measurement Measuring the magnet strength... 15:51:48 Integrated Voltage Measurement... 15:52:06 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.012918821 Vs 15:52:14 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.012721249 Vs 15:52:23 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.012913707 Vs 15:52:31 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.012723874 Vs 15:52:40 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.012923308 Vs 15:52:49 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.012711190 Vs 15:52:57 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.012939555 Vs 15:53:06 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.012702151 Vs 15:53:06 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.012819232 +- 0.000001360 Vs 15:53:06 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.012819232 +- 0.000001360 Vs BL = -0.12819232 +- 0.00001360 Tm 15:53:06 Integrated Voltage Measurement... 15:53:20 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.006641893 Vs 15:53:29 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.006397364 Vs 15:53:38 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.006649319 Vs 15:53:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.006391150 Vs 15:53:55 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.006655708 Vs 15:54:03 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.006386066 Vs 15:54:12 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.006659546 Vs 15:54:21 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.006388906 Vs 15:54:21 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.006521244 +- 0.000001778 Vs 15:54:21 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006521244 +- 0.000001778 Vs BL = -0.06521244 +- 0.00001778 Tm 15:54:21 Integrated Voltage Measurement... 15:54:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000361933 Vs 15:54:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000078552 Vs 15:54:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000367692 Vs 15:55:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000086977 Vs 15:55:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000367124 Vs 15:55:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000077651 Vs 15:55:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000366584 Vs 15:55:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000077220 Vs 15:55:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000222966 +- 0.000002644 Vs 15:55:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000222966 +- 0.000002644 Vs BL = -0.00222966 +- 0.00002644 Tm 15:55:36 Integrated Voltage Measurement... 15:55:50 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.005930406 Vs 15:55:59 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.006217411 Vs 15:56:07 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.005933341 Vs 15:56:16 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.006220877 Vs 15:56:24 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.005931792 Vs 15:56:33 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.006215915 Vs 15:56:42 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.005932094 Vs 15:56:50 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.006216347 Vs 15:56:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.006074773 +- 0.000001356 Vs 15:56:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.006074773 +- 0.000001356 Vs BL = 0.06074773 +- 0.00001356 Tm 15:56:50 Integrated Voltage Measurement... 15:57:05 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.012234567 Vs 15:57:13 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.012507935 Vs 15:57:22 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.012235276 Vs 15:57:31 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.012502848 Vs 15:57:39 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.012243937 Vs 15:57:48 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.012490419 Vs 15:57:56 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.012253170 Vs 15:58:05 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.012485287 Vs 15:58:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.012369180 +- 0.000001442 Vs 15:58:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.012369180 +- 0.000001442 Vs BL = 0.12369180 +- 0.00001442 Tm 15:58:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00224 0.00001 1 6.29728 0.00046 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 -0.12819 0.00001 -0.12818 -0.00001 -0.010000 -0.06521 0.00002 -0.06521 -0.00000 0.000000 -0.00223 0.00003 -0.00224 0.00001 0.010000 0.06075 0.00001 0.06073 0.00001 0.020000 0.12369 0.00001 0.12371 -0.00001 15:58:12 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 -0.12819 0.00001 -0.0100 -0.06521 0.00002 0.0000 -0.00223 0.00003 0.0100 0.06075 0.00001 0.0200 0.12369 0.00001 SL = 6.2972840 +- 0.0004551 Tm^2/m^n 15:58:12 Quadrupole Strength Calculation Check Slope = 6.297284 Tm/m, Inter = -0.002239 Tm, Sig_slope = 0.000432 Tm/m, Est_sig = 0.000014 Tm GL = 6.297284 +- 0.000432 T 15:58:12 Magnet Strength Measurement Harmonic Number = 2 SL = 6.2972840 +- 0.0004551 Tm^2/m^n 15:58:14 Magnet Current, Imag = 70.4621 A Vtrans = 5.636970 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:58:15 Magnet Current, Imag = 70.4617 A Vtrans = 5.636940 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:58:16 Magnet Current, Imag = 70.4612 A Vtrans = 5.636900 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:58:18 Magnet Current, Imag = 70.4615 A Vtrans = 5.636920 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:58:18 Magnet Current Measurement: Imag = 70.4617 +- 0.0003 A 15:58:18 Magnet current ramping to 80.0000 A... 15:58:54 Magnet Current, Imag = 80.6174 A Vtrans = 6.449390 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:58:55 Magnet Current, Imag = 80.6172 A Vtrans = 6.449380 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:58:56 Magnet Current, Imag = 80.6172 A Vtrans = 6.449380 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:58:58 Magnet Current, Imag = 80.6174 A Vtrans = 6.449390 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:58:58 Magnet Current Measurement: Imag = 80.6173 +- 0.0001 A 15:58:58 Magnetic Field Measurement Measuring the magnet strength... 15:58:58 Integrated Voltage Measurement... 15:59:16 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.014644855 Vs 15:59:24 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.014477440 Vs 15:59:33 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.014650347 Vs 15:59:42 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.014470168 Vs 15:59:50 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.014645013 Vs 15:59:59 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.014474975 Vs 16:00:07 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.014647460 Vs 16:00:16 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.014472429 Vs 16:00:16 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.014560336 +- 0.000000483 Vs 16:00:16 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.014560336 +- 0.000000483 Vs BL = -0.14560336 +- 0.00000483 Tm 16:00:16 Integrated Voltage Measurement... 16:00:31 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.007490587 Vs 16:00:39 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.007328385 Vs 16:00:48 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.007480777 Vs 16:00:56 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.007338098 Vs 16:01:05 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.007469716 Vs 16:01:14 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.007350292 Vs 16:01:22 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.007459994 Vs 16:01:31 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.007359482 Vs 16:01:31 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.007409667 +- 0.000000226 Vs 16:01:31 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.007409667 +- 0.000000226 Vs BL = -0.07409667 +- 0.00000226 Tm 16:01:31 Integrated Voltage Measurement... 16:01:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000292905 Vs 16:01:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000215714 Vs 16:02:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000292250 Vs 16:02:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000211548 Vs 16:02:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000297007 Vs 16:02:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000199791 Vs 16:02:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000307172 Vs 16:02:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000201174 Vs 16:02:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000252195 +- 0.000002392 Vs 16:02:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000252195 +- 0.000002392 Vs BL = -0.00252195 +- 0.00002392 Tm 16:02:46 Integrated Voltage Measurement... 16:03:00 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.006851223 Vs 16:03:09 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.006952479 Vs 16:03:17 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.006850944 Vs 16:03:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.006947666 Vs 16:03:35 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.006854212 Vs 16:03:43 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.006942048 Vs 16:03:52 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.006858940 Vs 16:04:00 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.006933139 Vs 16:04:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.006898831 +- 0.000002099 Vs 16:04:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.006898831 +- 0.000002099 Vs BL = 0.06898831 +- 0.00002099 Tm 16:04:01 Integrated Voltage Measurement... 16:04:15 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.014025249 Vs 16:04:23 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.014078632 Vs 16:04:32 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.014028036 Vs 16:04:41 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.014076232 Vs 16:04:49 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.014027257 Vs 16:04:58 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.014076035 Vs 16:05:07 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.014027323 Vs 16:05:15 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.014076898 Vs 16:05:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.014051958 +- 0.000000195 Vs 16:05:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.014051958 +- 0.000000195 Vs BL = 0.14051958 +- 0.00000195 Tm 16:05:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00254 0.00001 1 7.15331 0.00024 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 -0.14560 0.00000 -0.14561 0.00001 -0.010000 -0.07410 0.00000 -0.07408 -0.00002 0.000000 -0.00252 0.00002 -0.00254 0.00002 0.010000 0.06899 0.00002 0.06899 -0.00000 0.020000 0.14052 0.00000 0.14052 -0.00000 16:05:22 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 -0.14560 0.00000 -0.0100 -0.07410 0.00000 0.0000 -0.00252 0.00002 0.0100 0.06899 0.00002 0.0200 0.14052 0.00000 SL = 7.1533085 +- 0.0002355 Tm^2/m^n 16:05:22 Quadrupole Strength Calculation Check Slope = 7.153309 Tm/m, Inter = -0.002543 Tm, Sig_slope = 0.000553 Tm/m, Est_sig = 0.000017 Tm GL = 7.153309 +- 0.000553 T 16:05:23 Magnet Strength Measurement Harmonic Number = 2 SL = 7.1533085 +- 0.0002355 Tm^2/m^n 16:05:24 Magnet Current, Imag = 80.6202 A Vtrans = 6.449620 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:05:25 Magnet Current, Imag = 80.6201 A Vtrans = 6.449610 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:05:27 Magnet Current, Imag = 80.6202 A Vtrans = 6.449620 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:05:28 Magnet Current, Imag = 80.6200 A Vtrans = 6.449600 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:05:28 Magnet Current Measurement: Imag = 80.6202 +- 0.0001 A 16:05:28 Magnet current ramping to 90.0000 A... 16:06:04 Magnet Current, Imag = 90.6822 A Vtrans = 7.254580 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:06:05 Magnet Current, Imag = 90.6821 A Vtrans = 7.254570 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:06:07 Magnet Current, Imag = 90.6827 A Vtrans = 7.254620 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:06:08 Magnet Current, Imag = 90.6827 A Vtrans = 7.254620 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:06:08 Magnet Current Measurement: Imag = 90.6825 +- 0.0003 A 16:06:08 Magnetic Field Measurement Measuring the magnet strength... 16:06:08 Integrated Voltage Measurement... 16:06:26 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.016056611 Vs 16:06:35 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.016000044 Vs 16:06:44 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.016066359 Vs 16:06:52 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.015992802 Vs 16:07:01 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.016072793 Vs 16:07:10 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.015981937 Vs 16:07:18 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.016082503 Vs 16:07:27 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.015988461 Vs 16:07:27 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.016030189 +- 0.000003155 Vs 16:07:27 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.016030189 +- 0.000003155 Vs BL = -0.16030189 +- 0.00003155 Tm 16:07:27 Integrated Voltage Measurement... 16:07:41 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.008196629 Vs 16:07:50 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.008115505 Vs 16:07:58 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.008192157 Vs 16:08:07 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.008121965 Vs 16:08:16 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.008194871 Vs 16:08:24 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.008124271 Vs 16:08:33 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.008186016 Vs 16:08:42 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.008126734 Vs 16:08:42 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.008157268 +- 0.000001377 Vs 16:08:42 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.008157268 +- 0.000001377 Vs BL = -0.08157268 +- 0.00001377 Tm 16:08:42 Integrated Voltage Measurement... 16:08:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000298955 Vs 16:09:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000251428 Vs 16:09:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000293991 Vs 16:09:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000257273 Vs 16:09:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000300604 Vs 16:09:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000265983 Vs 16:09:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000290604 Vs 16:09:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000260527 Vs 16:09:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000277420 +- 0.000003395 Vs 16:09:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000277420 +- 0.000003395 Vs BL = -0.00277420 +- 0.00003395 Tm 16:09:56 Integrated Voltage Measurement... 16:10:11 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.007586837 Vs 16:10:19 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.007615795 Vs 16:10:28 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.007594530 Vs 16:10:37 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.007609619 Vs 16:10:45 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.007598129 Vs 16:10:54 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.007608780 Vs 16:11:02 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.007596785 Vs 16:11:11 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.007607278 Vs 16:11:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.007602219 +- 0.000000774 Vs 16:11:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.007602219 +- 0.000000774 Vs BL = 0.07602219 +- 0.00000774 Tm 16:11:11 Integrated Voltage Measurement... 16:11:26 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.015467672 Vs 16:11:34 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.015487278 Vs 16:11:43 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.015460864 Vs 16:11:51 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.015492497 Vs 16:12:00 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.015461779 Vs 16:12:09 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.015488153 Vs 16:12:17 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.015467097 Vs 16:12:26 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.015488264 Vs 16:12:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.015476701 +- 0.000001069 Vs 16:12:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.015476701 +- 0.000001069 Vs BL = 0.15476701 +- 0.00001069 Tm 16:12:33 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00277 0.00001 1 7.87733 0.00068 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 -0.16030 0.00003 -0.16032 0.00002 -0.010000 -0.08157 0.00001 -0.08155 -0.00003 0.000000 -0.00277 0.00003 -0.00277 -0.00000 0.010000 0.07602 0.00001 0.07600 0.00002 0.020000 0.15477 0.00001 0.15477 -0.00001 16:12:33 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 -0.16030 0.00003 -0.0100 -0.08157 0.00001 0.0000 -0.00277 0.00003 0.0100 0.07602 0.00001 0.0200 0.15477 0.00001 SL = 7.8773266 +- 0.0006847 Tm^2/m^n 16:12:33 Quadrupole Strength Calculation Check Slope = 7.877327 Tm/m, Inter = -0.002772 Tm, Sig_slope = 0.000714 Tm/m, Est_sig = 0.000023 Tm GL = 7.877327 +- 0.000714 T 16:12:33 Magnet Strength Measurement Harmonic Number = 2 SL = 7.8773266 +- 0.0006847 Tm^2/m^n 16:12:35 Magnet Current, Imag = 90.6851 A Vtrans = 7.254810 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:12:36 Magnet Current, Imag = 90.6852 A Vtrans = 7.254820 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:12:37 Magnet Current, Imag = 90.6851 A Vtrans = 7.254810 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:12:39 Magnet Current, Imag = 90.6849 A Vtrans = 7.254790 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:12:39 Magnet Current Measurement: Imag = 90.6851 +- 0.0001 A 16:12:39 Magnet current ramping to 0.0000 A...