SLAC Magnetic Measurements Date: 11-07-2003 Time: 16:18:08 Project: spear3 Magnet Type: quad Magnet Name: 34Q-047 Serial Number: Run Number: 2 Measurement Device: 10 wire Operator: sa Comment: b vs i. Swapped + and - inputs at integrator. Standardization: 3 cycles from 0.0 A to 98.0 A to 0.0 A Test Currents (A): 10.0 20.0 30.0 40.0 16:18:11 Initial Zero Current Measurement, Imag_zero = 0.0000 A 16:18:12 Magnet current ramping to 15.0000 A... 16:19:07 Magnet current ramping to 98.0000 A... 16:20:02 Magnet current ramping to 0.0000 A... 16:21:01 Magnet current ramping to 98.0000 A... 16:22:01 Magnet current ramping to 0.0000 A... 16:23:00 Magnet current ramping to 98.0000 A... 16:24:00 Magnet current ramping to 0.0000 A... 16:25:00 Magnet current ramping to 10.0000 A... 16:25:35 Magnet Current, Imag = 10.0051 A Vtrans = 0.800406 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:25:37 Magnet Current, Imag = 10.0055 A Vtrans = 0.800441 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:25:38 Magnet Current, Imag = 10.0049 A Vtrans = 0.800394 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:25:39 Magnet Current, Imag = 10.0048 A Vtrans = 0.800387 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:25:39 Magnet Current Measurement: Imag = 10.0051 +- 0.0003 A 16:25:39 Magnetic Field Measurement Measuring the magnet strength... 16:25:39 Integrated Voltage Measurement... 16:25:57 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.001763875 Vs 16:26:06 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.001667315 Vs 16:26:14 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.001764542 Vs 16:26:23 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.001673999 Vs 16:26:32 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.001758810 Vs 16:26:40 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.001676477 Vs 16:26:49 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.001759008 Vs 16:26:57 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.001671727 Vs 16:26:57 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.001716969 +- 0.000001597 Vs 16:26:57 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.001716969 +- 0.000001597 Vs BL = 0.01716969 +- 0.00001597 Tm 16:26:57 Integrated Voltage Measurement... 16:27:12 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000850982 Vs 16:27:20 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000771285 Vs 16:27:29 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000854447 Vs 16:27:37 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000765585 Vs 16:27:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000859210 Vs 16:27:55 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000761669 Vs 16:28:03 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000864944 Vs 16:28:12 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.000766627 Vs 16:28:12 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.000811844 +- 0.000002310 Vs 16:28:12 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000811844 +- 0.000002310 Vs BL = 0.00811844 +- 0.00002310 Tm 16:28:12 Integrated Voltage Measurement... 16:28:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000042693 Vs 16:28:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000136966 Vs 16:28:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000047620 Vs 16:28:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000138296 Vs 16:29:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000052666 Vs 16:29:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000131931 Vs 16:29:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000055169 Vs 16:29:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000132904 Vs 16:29:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000092281 +- 0.000001545 Vs 16:29:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000092281 +- 0.000001545 Vs BL = -0.00092281 +- 0.00001545 Tm 16:29:26 Integrated Voltage Measurement... 16:29:41 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000960601 Vs 16:29:49 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001034832 Vs 16:29:58 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000955333 Vs 16:30:06 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001040023 Vs 16:30:15 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000952592 Vs 16:30:23 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001047557 Vs 16:30:32 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.000965512 Vs 16:30:41 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001052557 Vs 16:30:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001001126 +- 0.000004668 Vs 16:30:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001001126 +- 0.000004668 Vs BL = -0.01001126 +- 0.00004668 Tm 16:30:41 Integrated Voltage Measurement... 16:30:55 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.001848053 Vs 16:31:04 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.001943742 Vs 16:31:12 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.001852203 Vs 16:31:21 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.001939749 Vs 16:31:29 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.001857291 Vs 16:31:38 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.001941530 Vs 16:31:46 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.001860901 Vs 16:31:55 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.001936099 Vs 16:31:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.001897446 +- 0.000001544 Vs 16:31:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001897446 +- 0.000001544 Vs BL = -0.01897446 +- 0.00001544 Tm 16:32:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00092 0.00001 1 -0.90418 0.00068 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 0.01717 0.00002 0.01716 0.00001 -0.010000 0.00812 0.00002 0.00812 0.00000 0.000000 -0.00092 0.00002 -0.00092 0.00000 0.010000 -0.01001 0.00005 -0.00997 -0.00005 0.020000 -0.01897 0.00002 -0.01901 0.00003 16:32:02 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 0.01717 0.00002 -0.0100 0.00812 0.00002 0.0000 -0.00092 0.00002 0.0100 -0.01001 0.00005 0.0200 -0.01897 0.00002 SL = -0.9041800 +- 0.0006846 Tm^2/m^n 16:32:02 Quadrupole Strength Calculation Check Slope = -0.904180 Tm/m, Inter = -0.000924 Tm, Sig_slope = 0.001044 Tm/m, Est_sig = 0.000033 Tm GL = -0.904180 +- 0.001044 T 16:32:02 Magnet Strength Measurement Harmonic Number = 2 SL = -0.9041800 +- 0.0006846 Tm^2/m^n 16:32:03 Magnet Current, Imag = 10.0042 A Vtrans = 0.800337 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:32:05 Magnet Current, Imag = 10.0037 A Vtrans = 0.800297 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:32:06 Magnet Current, Imag = 10.0041 A Vtrans = 0.800328 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:32:07 Magnet Current, Imag = 10.0042 A Vtrans = 0.800338 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:32:07 Magnet Current Measurement: Imag = 10.0041 +- 0.0002 A 16:32:07 Magnet current ramping to 20.0000 A... 16:32:43 Magnet Current, Imag = 20.0696 A Vtrans = 1.605568 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:32:44 Magnet Current, Imag = 20.0694 A Vtrans = 1.605551 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:32:45 Magnet Current, Imag = 20.0697 A Vtrans = 1.605575 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:32:46 Magnet Current, Imag = 20.0694 A Vtrans = 1.605556 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:32:46 Magnet Current Measurement: Imag = 20.0695 +- 0.0001 A 16:32:46 Magnetic Field Measurement Measuring the magnet strength... 16:32:46 Integrated Voltage Measurement... 16:33:04 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003454640 Vs 16:33:13 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003391080 Vs 16:33:21 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003450563 Vs 16:33:30 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003393992 Vs 16:33:39 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003444839 Vs 16:33:47 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003396844 Vs 16:33:56 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003441047 Vs 16:34:04 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.003396179 Vs 16:34:04 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.003421148 +- 0.000001638 Vs 16:34:04 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003421148 +- 0.000001638 Vs BL = 0.03421148 +- 0.00001638 Tm 16:34:04 Integrated Voltage Measurement... 16:34:19 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001633783 Vs 16:34:27 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001583900 Vs 16:34:36 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001642312 Vs 16:34:45 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001581138 Vs 16:34:53 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001640583 Vs 16:35:02 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001582718 Vs 16:35:10 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001639914 Vs 16:35:19 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.001581830 Vs 16:35:19 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.001610772 +- 0.000001164 Vs 16:35:19 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.001610772 +- 0.000001164 Vs BL = 0.01610772 +- 0.00001164 Tm 16:35:19 Integrated Voltage Measurement... 16:35:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000166520 Vs 16:35:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000220810 Vs 16:35:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000163647 Vs 16:35:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000225125 Vs 16:36:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000167783 Vs 16:36:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000225865 Vs 16:36:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000168120 Vs 16:36:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000217601 Vs 16:36:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000194434 +- 0.000001482 Vs 16:36:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000194434 +- 0.000001482 Vs BL = -0.00194434 +- 0.00001482 Tm 16:36:34 Integrated Voltage Measurement... 16:36:48 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001990427 Vs 16:36:56 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002006571 Vs 16:37:05 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001998507 Vs 16:37:14 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.001997385 Vs 16:37:22 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001997403 Vs 16:37:31 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002003257 Vs 16:37:39 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001995559 Vs 16:37:48 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.002008426 Vs 16:37:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.001999692 +- 0.000001595 Vs 16:37:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001999692 +- 0.000001595 Vs BL = -0.01999692 +- 0.00001595 Tm 16:37:48 Integrated Voltage Measurement... 16:38:02 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.003787029 Vs 16:38:11 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.003825608 Vs 16:38:20 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.003781895 Vs 16:38:28 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.003842118 Vs 16:38:37 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.003758604 Vs 16:38:45 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.003851698 Vs 16:38:54 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.003757481 Vs 16:39:03 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.003851538 Vs 16:39:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.003806996 +- 0.000002964 Vs 16:39:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003806996 +- 0.000002964 Vs BL = -0.03806996 +- 0.00002964 Tm 16:39:10 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00194 0.00001 1 -1.80668 0.00071 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 0.03421 0.00002 0.03420 0.00002 -0.010000 0.01611 0.00001 0.01613 -0.00002 0.000000 -0.00194 0.00001 -0.00194 -0.00001 0.010000 -0.02000 0.00002 -0.02001 0.00001 0.020000 -0.03807 0.00003 -0.03807 0.00000 16:39:10 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 0.03421 0.00002 -0.0100 0.01611 0.00001 0.0000 -0.00194 0.00001 0.0100 -0.02000 0.00002 0.0200 -0.03807 0.00003 SL = -1.8066753 +- 0.0007055 Tm^2/m^n 16:39:10 Quadrupole Strength Calculation Check Slope = -1.806675 Tm/m, Inter = -0.001938 Tm, Sig_slope = 0.000517 Tm/m, Est_sig = 0.000016 Tm GL = -1.806675 +- 0.000517 T 16:39:10 Magnet Strength Measurement Harmonic Number = 2 SL = -1.8066753 +- 0.0007055 Tm^2/m^n 16:39:11 Magnet Current, Imag = 20.0694 A Vtrans = 1.605549 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:39:13 Magnet Current, Imag = 20.0694 A Vtrans = 1.605548 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:39:14 Magnet Current, Imag = 20.0687 A Vtrans = 1.605499 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:39:15 Magnet Current, Imag = 20.0695 A Vtrans = 1.605561 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:39:15 Magnet Current Measurement: Imag = 20.0692 +- 0.0003 A 16:39:15 Magnet current ramping to 30.0000 A... 16:39:50 Magnet Current, Imag = 30.1335 A Vtrans = 2.410683 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:39:52 Magnet Current, Imag = 30.1329 A Vtrans = 2.410630 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:39:53 Magnet Current, Imag = 30.1329 A Vtrans = 2.410631 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:39:54 Magnet Current, Imag = 30.1329 A Vtrans = 2.410631 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:39:54 Magnet Current Measurement: Imag = 30.1330 +- 0.0003 A 16:39:54 Magnetic Field Measurement Measuring the magnet strength... 16:39:54 Integrated Voltage Measurement... 16:40:12 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005181783 Vs 16:40:21 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.005081286 Vs 16:40:29 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005170979 Vs 16:40:38 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.005090724 Vs 16:40:47 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005162855 Vs 16:40:55 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.005098675 Vs 16:41:04 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005156213 Vs 16:41:12 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.005101854 Vs 16:41:12 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.005130546 +- 0.000000923 Vs 16:41:12 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005130546 +- 0.000000923 Vs BL = 0.05130546 +- 0.00000923 Tm 16:41:12 Integrated Voltage Measurement... 16:41:27 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002435322 Vs 16:41:35 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002395400 Vs 16:41:44 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002431549 Vs 16:41:53 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002395363 Vs 16:42:01 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002437050 Vs 16:42:10 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002387520 Vs 16:42:18 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002442586 Vs 16:42:27 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.002381814 Vs 16:42:27 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.002413325 +- 0.000001276 Vs 16:42:27 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.002413325 +- 0.000001276 Vs BL = 0.02413325 +- 0.00001276 Tm 16:42:27 Integrated Voltage Measurement... 16:42:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000254355 Vs 16:42:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000342360 Vs 16:42:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000253601 Vs 16:43:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000348441 Vs 16:43:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000236434 Vs 16:43:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000360987 Vs 16:43:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000224943 Vs 16:43:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000366847 Vs 16:43:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000298496 +- 0.000001817 Vs 16:43:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000298496 +- 0.000001817 Vs BL = -0.00298496 +- 0.00001817 Tm 16:43:42 Integrated Voltage Measurement... 16:43:56 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002942972 Vs 16:44:04 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003074659 Vs 16:44:13 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002941857 Vs 16:44:22 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003071331 Vs 16:44:30 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002941527 Vs 16:44:39 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003071210 Vs 16:44:47 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.002943493 Vs 16:44:56 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.003067935 Vs 16:44:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003006873 +- 0.000001167 Vs 16:44:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003006873 +- 0.000001167 Vs BL = -0.03006873 +- 0.00001167 Tm 16:44:56 Integrated Voltage Measurement... 16:45:10 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005645007 Vs 16:45:19 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005788205 Vs 16:45:28 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005639374 Vs 16:45:36 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005788340 Vs 16:45:45 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005644581 Vs 16:45:53 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005785441 Vs 16:46:02 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005644760 Vs 16:46:10 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.005790587 Vs 16:46:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.005715787 +- 0.000001463 Vs 16:46:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005715787 +- 0.000001463 Vs BL = -0.05715787 +- 0.00001463 Tm 16:46:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00295 0.00001 1 -2.71129 0.00039 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 0.05131 0.00001 0.05127 0.00003 -0.010000 0.02413 0.00001 0.02416 -0.00003 0.000000 -0.00298 0.00002 -0.00295 -0.00003 0.010000 -0.03007 0.00001 -0.03007 -0.00000 0.020000 -0.05716 0.00001 -0.05718 0.00002 16:46:18 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 0.05131 0.00001 -0.0100 0.02413 0.00001 0.0000 -0.00298 0.00002 0.0100 -0.03007 0.00001 0.0200 -0.05716 0.00001 SL = -2.7112864 +- 0.0003867 Tm^2/m^n 16:46:18 Quadrupole Strength Calculation Check Slope = -2.711286 Tm/m, Inter = -0.002955 Tm, Sig_slope = 0.001038 Tm/m, Est_sig = 0.000033 Tm GL = -2.711286 +- 0.001038 T 16:46:18 Magnet Strength Measurement Harmonic Number = 2 SL = -2.7112864 +- 0.0003867 Tm^2/m^n 16:46:19 Magnet Current, Imag = 30.1337 A Vtrans = 2.410697 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:46:20 Magnet Current, Imag = 30.1338 A Vtrans = 2.410706 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:46:21 Magnet Current, Imag = 30.1337 A Vtrans = 2.410700 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:46:23 Magnet Current, Imag = 30.1332 A Vtrans = 2.410656 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:46:23 Magnet Current Measurement: Imag = 30.1336 +- 0.0002 A 16:46:23 Magnet current ramping to 40.0000 A... 16:46:59 Magnet Current, Imag = 40.2164 A Vtrans = 3.217310 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:47:00 Magnet Current, Imag = 40.2169 A Vtrans = 3.217350 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:47:02 Magnet Current, Imag = 40.2169 A Vtrans = 3.217350 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:47:04 Magnet Current, Imag = 40.2165 A Vtrans = 3.217320 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:47:04 Magnet Current Measurement: Imag = 40.2167 +- 0.0002 A 16:47:04 Magnetic Field Measurement Measuring the magnet strength... 16:47:04 Integrated Voltage Measurement... 16:47:22 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006915251 Vs 16:47:30 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006753950 Vs 16:47:39 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006917127 Vs 16:47:48 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006764514 Vs 16:47:56 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006918750 Vs 16:48:05 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006762353 Vs 16:48:13 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006913217 Vs 16:48:22 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = -0.006762560 Vs 16:48:22 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = 0.006838465 +- 0.000002509 Vs 16:48:22 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.006838465 +- 0.000002509 Vs BL = 0.06838465 +- 0.00002509 Tm 16:48:22 Integrated Voltage Measurement... 16:48:36 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003291718 Vs 16:48:45 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003147566 Vs 16:48:54 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003290123 Vs 16:49:02 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003146975 Vs 16:49:11 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003291760 Vs 16:49:19 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003151177 Vs 16:49:28 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003284532 Vs 16:49:37 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = -0.003155156 Vs 16:49:37 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = 0.003219876 +- 0.000001043 Vs 16:49:37 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003219876 +- 0.000001043 Vs BL = 0.03219876 +- 0.00001043 Tm 16:49:37 Integrated Voltage Measurement... 16:49:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000336991 Vs 16:50:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000464256 Vs 16:50:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000335576 Vs 16:50:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000465927 Vs 16:50:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000329763 Vs 16:50:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000467368 Vs 16:50:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000325436 Vs 16:50:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000467535 Vs 16:50:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000399107 +- 0.000001744 Vs 16:50:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000399107 +- 0.000001744 Vs BL = -0.00399107 +- 0.00001744 Tm 16:50:51 Integrated Voltage Measurement... 16:51:06 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003940451 Vs 16:51:14 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004097010 Vs 16:51:23 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003938316 Vs 16:51:31 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004087642 Vs 16:51:40 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003940837 Vs 16:51:49 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004087097 Vs 16:51:57 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.003943586 Vs 16:52:06 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = 0.004089708 Vs 16:52:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = -0.004015581 +- 0.000002260 Vs 16:52:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004015581 +- 0.000002260 Vs BL = -0.04015581 +- 0.00002260 Tm 16:52:06 Integrated Voltage Measurement... 16:52:20 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.007551493 Vs 16:52:29 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.007705075 Vs 16:52:37 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.007552392 Vs 16:52:46 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.007713198 Vs 16:52:55 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.007536792 Vs 16:53:03 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.007719128 Vs 16:53:12 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.007540742 Vs 16:53:20 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = 0.007715026 Vs 16:53:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = -0.007629231 +- 0.000002063 Vs 16:53:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.007629231 +- 0.000002063 Vs BL = -0.07629231 +- 0.00002063 Tm 16:53:28 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00397 0.00001 1 -3.61708 0.00070 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 0.06838 0.00003 0.06837 0.00001 -0.010000 0.03220 0.00001 0.03220 -0.00000 0.000000 -0.00399 0.00002 -0.00397 -0.00002 0.010000 -0.04016 0.00002 -0.04014 -0.00001 0.020000 -0.07629 0.00002 -0.07631 0.00002 16:53:28 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 0.06838 0.00003 -0.0100 0.03220 0.00001 0.0000 -0.00399 0.00002 0.0100 -0.04016 0.00002 0.0200 -0.07629 0.00002 SL = -3.6170849 +- 0.0006957 Tm^2/m^n 16:53:28 Quadrupole Strength Calculation Check Slope = -3.617085 Tm/m, Inter = -0.003971 Tm, Sig_slope = 0.000635 Tm/m, Est_sig = 0.000020 Tm GL = -3.617085 +- 0.000635 T 16:53:28 Magnet Strength Measurement Harmonic Number = 2 SL = -3.6170849 +- 0.0006957 Tm^2/m^n 16:53:29 Magnet Current, Imag = 40.2172 A Vtrans = 3.217380 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:53:31 Magnet Current, Imag = 40.2171 A Vtrans = 3.217370 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:53:33 Magnet Current, Imag = 40.2170 A Vtrans = 3.217360 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:53:34 Magnet Current, Imag = 40.2167 A Vtrans = 3.217340 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 16:53:35 Magnet Current Measurement: Imag = 40.2170 +- 0.0002 A 16:53:35 Magnet current ramping to 0.0000 A...