SLAC Magnetic Measurements Date: 11-13-2003 Time: 14:23:54 Project: spear3 Magnet Type: quad Magnet Name: 34Q-047 Serial Number: Run Number: 3 Measurement Device: Spear3q Coil Operator: sa Comment: Coil Calibration and center check. Standardization: 3 cycles from 0.0 A to 98.0 A to 0.0 A Test Currents (A): 10.0 50.0 90.0 Integrated Gradient Imag sigImag GL sigGL GL/I sigGL/I THsp sigTHsp (A) (A) (T) (T) (T/A) (T/A) (deg) (deg) --------+-------- ----------+---------- ----------+---------- ----------+---------- 9.933 0.000 0.886939 0.000017 0.089291470 0.000001750 -44.8388 0.0004 49.968 0.000 4.437574 0.000060 0.088808480 0.000001204 -44.8376 0.0003 89.986 0.000 7.762938 0.000195 0.086268311 0.000002165 -44.8368 0.0003