SLAC Magnetic Measurements Date: 04-20-2001 Time: 12:53:04 Project: spear3 Magnet Type: gdipole Magnet Name: proto_test_stand Serial Number: Run Number: 75 Measurement Device: single wire Operator: jy Comment: BL vs. I, DAC A/V ratio changed, hysteresis curve incl. Standardization: 1 cycles from 0.0 A to 770.0 A to 0.0 A Test Currents (A): 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 500.0 525.0 550.0 575.0 600.0 625.0 650.0 675.0 700.0 650.0 600.0 550.0 500.0 450.0 400.0 350.0 300.0 250.0 200.0 150.0 100.0 50.0 12:53:13 Initial Zero Current Measurement, Imag_zero = 0.0000 A 12:53:13 Magnet current ramping to 15.0000 A... 12:54:09 Magnet current ramping to 770.0000 A... 12:58:23 Magnet current ramping to 0.0000 A... 13:03:09 Magnet current ramping to 50.0000 A... 13:03:58 Magnet Current, Imag = 49.8138 A Vtrans = 0.498138 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:03:59 Magnet Current, Imag = 49.7996 A Vtrans = 0.497996 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:04:00 Magnet Current, Imag = 49.7949 A Vtrans = 0.497949 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:04:02 Magnet Current, Imag = 49.8212 A Vtrans = 0.498212 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:04:02 Magnet Current Measurement: Imag = 49.8074 +- 0.0106 A 13:04:02 Magnetic Field Measurement Measuring the magnet strength... 13:04:02 Integrated Voltage Measurement... 13:04:19 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.001731926 Vs 13:04:29 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.001264450 Vs 13:04:40 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.001730263 Vs 13:04:51 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.001267025 Vs 13:05:01 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.001740931 Vs 13:05:12 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.001262137 Vs 13:05:23 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.001735752 Vs 13:05:33 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.001265408 Vs 13:05:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.001499736 +- 0.000001372 Vs 13:05:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001499736 +- 0.000001372 Vs BL = 0.14997365 +- 0.00013724 Tm 13:05:40 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.14997 0.00014 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 0.14997 0.00014 0.14997 0.00000 13:05:40 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 0.14997 0.00014 SL = 0.1499736 +- 0.0001372 Tm^2/m^n 13:05:40 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1499736 +- 0.0001372 Tm^2/m^n 13:05:42 Magnet Current, Imag = 49.7763 A Vtrans = 0.497763 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:05:43 Magnet Current, Imag = 49.8044 A Vtrans = 0.498044 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:05:45 Magnet Current, Imag = 49.8244 A Vtrans = 0.498244 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:05:46 Magnet Current, Imag = 49.8041 A Vtrans = 0.498041 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:05:46 Magnet Current Measurement: Imag = 49.8023 +- 0.0171 A 13:05:46 Magnet current ramping to 100.0000 A... 13:06:34 Magnet Current, Imag = 99.7973 A Vtrans = 0.997973 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:06:35 Magnet Current, Imag = 99.8345 A Vtrans = 0.998345 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:06:37 Magnet Current, Imag = 99.8387 A Vtrans = 0.998387 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:06:38 Magnet Current, Imag = 99.8494 A Vtrans = 0.998494 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:06:38 Magnet Current Measurement: Imag = 99.8300 +- 0.0196 A 13:06:38 Magnetic Field Measurement Measuring the magnet strength... 13:06:39 Integrated Voltage Measurement... 13:06:55 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.003222047 Vs 13:07:06 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.002739291 Vs 13:07:16 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.003223424 Vs 13:07:27 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.002739154 Vs 13:07:38 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.003216375 Vs 13:07:48 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.002738800 Vs 13:07:59 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.003214342 Vs 13:08:10 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.002748019 Vs 13:08:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.002980181 +- 0.000001516 Vs 13:08:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.002980181 +- 0.000001516 Vs BL = 0.29801815 +- 0.00015158 Tm 13:08:17 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.29802 0.00015 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 0.29802 0.00015 0.29802 0.00000 13:08:17 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 0.29802 0.00015 SL = 0.2980181 +- 0.0001516 Tm^2/m^n 13:08:17 Magnet Strength Measurement Harmonic Number = 1 SL = 0.2980181 +- 0.0001516 Tm^2/m^n 13:08:18 Magnet Current, Imag = 99.8391 A Vtrans = 0.998391 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:20 Magnet Current, Imag = 99.8214 A Vtrans = 0.998214 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:21 Magnet Current, Imag = 99.8359 A Vtrans = 0.998359 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:23 Magnet Current, Imag = 99.8134 A Vtrans = 0.998134 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:23 Magnet Current Measurement: Imag = 99.8274 +- 0.0105 A 13:08:23 Magnet current ramping to 150.0000 A... 13:09:11 Magnet Current, Imag = 149.8504 A Vtrans = 1.498504 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:09:12 Magnet Current, Imag = 149.8653 A Vtrans = 1.498653 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:09:13 Magnet Current, Imag = 149.8471 A Vtrans = 1.498471 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:09:15 Magnet Current, Imag = 149.9030 A Vtrans = 1.499030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:09:15 Magnet Current Measurement: Imag = 149.8664 +- 0.0222 A 13:09:15 Magnetic Field Measurement Measuring the magnet strength... 13:09:15 Integrated Voltage Measurement... 13:09:32 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.004714998 Vs 13:09:42 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.004237457 Vs 13:09:53 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.004705480 Vs 13:10:04 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.004222279 Vs 13:10:14 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.004710521 Vs 13:10:25 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.004230527 Vs 13:10:36 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.004705814 Vs 13:10:46 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.004231417 Vs 13:10:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.004469812 +- 0.000004424 Vs 13:10:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004469812 +- 0.000004424 Vs BL = 0.44698117 +- 0.00044240 Tm 13:10:53 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.44698 0.00044 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 0.44698 0.00044 0.44698 0.00000 13:10:53 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 0.44698 0.00044 SL = 0.4469812 +- 0.0004424 Tm^2/m^n 13:10:53 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4469812 +- 0.0004424 Tm^2/m^n 13:10:55 Magnet Current, Imag = 149.8580 A Vtrans = 1.498580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:56 Magnet Current, Imag = 149.8571 A Vtrans = 1.498571 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:58 Magnet Current, Imag = 149.8254 A Vtrans = 1.498254 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:59 Magnet Current, Imag = 149.8335 A Vtrans = 1.498335 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:59 Magnet Current Measurement: Imag = 149.8435 +- 0.0143 A 13:11:00 Magnet current ramping to 200.0000 A... 13:11:47 Magnet Current, Imag = 199.8473 A Vtrans = 1.998473 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:11:49 Magnet Current, Imag = 199.8399 A Vtrans = 1.998399 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:11:50 Magnet Current, Imag = 199.8338 A Vtrans = 1.998338 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:11:52 Magnet Current, Imag = 199.8300 A Vtrans = 1.998300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:11:52 Magnet Current Measurement: Imag = 199.8377 +- 0.0065 A 13:11:52 Magnetic Field Measurement Measuring the magnet strength... 13:11:52 Integrated Voltage Measurement... 13:12:08 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.006194009 Vs 13:12:19 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.005727714 Vs 13:12:30 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.006207979 Vs 13:12:41 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.005726683 Vs 13:12:51 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.006188826 Vs 13:13:02 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.005718607 Vs 13:13:13 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.006192315 Vs 13:13:23 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.005714220 Vs 13:13:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.005958794 +- 0.000005777 Vs 13:13:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.005958794 +- 0.000005777 Vs BL = 0.59587942 +- 0.00057767 Tm 13:13:30 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.59588 0.00058 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 0.59588 0.00058 0.59588 0.00000 13:13:30 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 0.59588 0.00058 SL = 0.5958794 +- 0.0005777 Tm^2/m^n 13:13:30 Magnet Strength Measurement Harmonic Number = 1 SL = 0.5958794 +- 0.0005777 Tm^2/m^n 13:13:32 Magnet Current, Imag = 199.8610 A Vtrans = 1.998610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:13:33 Magnet Current, Imag = 199.8550 A Vtrans = 1.998550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:13:35 Magnet Current, Imag = 199.8255 A Vtrans = 1.998255 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:13:36 Magnet Current, Imag = 199.8234 A Vtrans = 1.998234 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:13:36 Magnet Current Measurement: Imag = 199.8412 +- 0.0169 A 13:13:36 Magnet current ramping to 250.0000 A... 13:14:24 Magnet Current, Imag = 249.8823 A Vtrans = 2.498823 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:14:25 Magnet Current, Imag = 249.8997 A Vtrans = 2.498997 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:14:27 Magnet Current, Imag = 249.8950 A Vtrans = 2.498950 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:14:28 Magnet Current, Imag = 249.8818 A Vtrans = 2.498818 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:14:28 Magnet Current Measurement: Imag = 249.8897 +- 0.0078 A 13:14:29 Magnetic Field Measurement Measuring the magnet strength... 13:14:29 Integrated Voltage Measurement... 13:14:45 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.007692029 Vs 13:14:56 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.007217163 Vs 13:15:06 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.007711753 Vs 13:15:17 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.007223631 Vs 13:15:28 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.007676940 Vs 13:15:39 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.007217779 Vs 13:15:49 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.007695613 Vs 13:16:00 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.007210892 Vs 13:16:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.007455725 +- 0.000007426 Vs 13:16:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.007455725 +- 0.000007426 Vs BL = 0.74557251 +- 0.00074260 Tm 13:16:07 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.74557 0.00074 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 0.74557 0.00074 0.74557 0.00000 13:16:07 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 0.74557 0.00074 SL = 0.7455725 +- 0.0007426 Tm^2/m^n 13:16:07 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7455725 +- 0.0007426 Tm^2/m^n 13:16:08 Magnet Current, Imag = 249.8758 A Vtrans = 2.498758 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:16:10 Magnet Current, Imag = 249.8726 A Vtrans = 2.498726 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:16:11 Magnet Current, Imag = 249.8649 A Vtrans = 2.498649 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:16:13 Magnet Current, Imag = 249.8701 A Vtrans = 2.498701 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:16:13 Magnet Current Measurement: Imag = 249.8708 +- 0.0040 A 13:16:13 Magnet current ramping to 300.0000 A... 13:17:01 Magnet Current, Imag = 299.8931 A Vtrans = 2.998931 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:17:02 Magnet Current, Imag = 299.9034 A Vtrans = 2.999034 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:17:04 Magnet Current, Imag = 299.9091 A Vtrans = 2.999091 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:17:05 Magnet Current, Imag = 299.9073 A Vtrans = 2.999073 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:17:05 Magnet Current Measurement: Imag = 299.9032 +- 0.0062 A 13:17:05 Magnetic Field Measurement Measuring the magnet strength... 13:17:05 Integrated Voltage Measurement... 13:17:22 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.009198330 Vs 13:17:33 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.008715096 Vs 13:17:43 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.009183661 Vs 13:17:54 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.008707739 Vs 13:18:04 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.009174875 Vs 13:18:15 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.008702799 Vs 13:18:26 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.009182195 Vs 13:18:36 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.008717941 Vs 13:18:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.008947830 +- 0.000006506 Vs 13:18:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.008947830 +- 0.000006506 Vs BL = 0.89478297 +- 0.00065061 Tm 13:18:43 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.89478 0.00065 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 0.89478 0.00065 0.89478 0.00000 13:18:43 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 0.89478 0.00065 SL = 0.8947830 +- 0.0006506 Tm^2/m^n 13:18:43 Magnet Strength Measurement Harmonic Number = 1 SL = 0.8947830 +- 0.0006506 Tm^2/m^n 13:18:45 Magnet Current, Imag = 299.8929 A Vtrans = 2.998929 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:18:46 Magnet Current, Imag = 299.9021 A Vtrans = 2.999021 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:18:48 Magnet Current, Imag = 299.9186 A Vtrans = 2.999186 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:18:49 Magnet Current, Imag = 299.9721 A Vtrans = 2.999721 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:18:49 Magnet Current Measurement: Imag = 299.9214 +- 0.0307 A 13:18:49 Magnet current ramping to 350.0000 A... 13:19:38 Magnet Current, Imag = 349.9470 A Vtrans = 3.499470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:19:39 Magnet Current, Imag = 349.9320 A Vtrans = 3.499320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:19:41 Magnet Current, Imag = 349.9330 A Vtrans = 3.499330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:19:43 Magnet Current, Imag = 349.9210 A Vtrans = 3.499210 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:19:43 Magnet Current Measurement: Imag = 349.9332 +- 0.0092 A 13:19:44 Magnetic Field Measurement Measuring the magnet strength... 13:19:44 Integrated Voltage Measurement... 13:20:00 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.010670991 Vs 13:20:11 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.010196871 Vs 13:20:22 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.010674755 Vs 13:20:32 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.010202756 Vs 13:20:43 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.010664985 Vs 13:20:54 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.010203227 Vs 13:21:04 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.010673796 Vs 13:21:15 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.010202584 Vs 13:21:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.010436245 +- 0.000002237 Vs 13:21:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.010436245 +- 0.000002237 Vs BL = 1.04362455 +- 0.00022370 Tm 13:21:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.04362 0.00022 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 1.04362 0.00022 1.04362 0.00000 13:21:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 1.04362 0.00022 SL = 1.0436245 +- 0.0002237 Tm^2/m^n 13:21:22 Magnet Strength Measurement Harmonic Number = 1 SL = 1.0436245 +- 0.0002237 Tm^2/m^n 13:21:24 Magnet Current, Imag = 349.9430 A Vtrans = 3.499430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:21:26 Magnet Current, Imag = 349.9320 A Vtrans = 3.499320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:21:28 Magnet Current, Imag = 349.9270 A Vtrans = 3.499270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:21:29 Magnet Current, Imag = 349.9000 A Vtrans = 3.499000 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:21:30 Magnet Current Measurement: Imag = 349.9255 +- 0.0158 A 13:21:30 Magnet current ramping to 400.0000 A... 13:22:18 Magnet Current, Imag = 399.9080 A Vtrans = 3.999080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:22:20 Magnet Current, Imag = 399.9120 A Vtrans = 3.999120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:22:21 Magnet Current, Imag = 399.9140 A Vtrans = 3.999140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:22:23 Magnet Current, Imag = 399.9230 A Vtrans = 3.999230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:22:23 Magnet Current Measurement: Imag = 399.9142 +- 0.0055 A 13:22:23 Magnetic Field Measurement Measuring the magnet strength... 13:22:23 Integrated Voltage Measurement... 13:22:40 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.012165167 Vs 13:22:50 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.011693976 Vs 13:23:01 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.012172359 Vs 13:23:12 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.011692855 Vs 13:23:22 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.012159211 Vs 13:23:33 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.011687486 Vs 13:23:44 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.012166787 Vs 13:23:54 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.011686836 Vs 13:23:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.011928084 +- 0.000003417 Vs 13:23:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.011928084 +- 0.000003417 Vs BL = 1.19280845 +- 0.00034175 Tm 13:24:01 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.19281 0.00034 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 1.19281 0.00034 1.19281 0.00000 13:24:01 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 1.19281 0.00034 SL = 1.1928084 +- 0.0003417 Tm^2/m^n 13:24:01 Magnet Strength Measurement Harmonic Number = 1 SL = 1.1928084 +- 0.0003417 Tm^2/m^n 13:24:03 Magnet Current, Imag = 399.9190 A Vtrans = 3.999190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:24:04 Magnet Current, Imag = 399.9230 A Vtrans = 3.999230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:24:06 Magnet Current, Imag = 399.9300 A Vtrans = 3.999300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:24:07 Magnet Current, Imag = 399.9240 A Vtrans = 3.999240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:24:07 Magnet Current Measurement: Imag = 399.9240 +- 0.0039 A 13:24:08 Magnet current ramping to 450.0000 A... 13:24:56 Magnet Current, Imag = 449.9990 A Vtrans = 4.499990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:24:57 Magnet Current, Imag = 449.9100 A Vtrans = 4.499100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:24:59 Magnet Current, Imag = 449.9790 A Vtrans = 4.499790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:25:00 Magnet Current, Imag = 449.9740 A Vtrans = 4.499740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:25:00 Magnet Current Measurement: Imag = 449.9655 +- 0.0334 A 13:25:01 Magnetic Field Measurement Measuring the magnet strength... 13:25:01 Integrated Voltage Measurement... 13:25:17 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.013659638 Vs 13:25:28 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.013172109 Vs 13:25:39 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.013648619 Vs 13:25:49 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.013176126 Vs 13:26:00 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.013639179 Vs 13:26:11 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.013172416 Vs 13:26:21 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.013667160 Vs 13:26:32 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.013179732 Vs 13:26:32 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.013414372 +- 0.000006366 Vs 13:26:32 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.013414372 +- 0.000006366 Vs BL = 1.34143722 +- 0.00063662 Tm 13:26:39 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.34144 0.00064 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 1.34144 0.00064 1.34144 0.00000 13:26:39 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 1.34144 0.00064 SL = 1.3414372 +- 0.0006366 Tm^2/m^n 13:26:39 Magnet Strength Measurement Harmonic Number = 1 SL = 1.3414372 +- 0.0006366 Tm^2/m^n 13:26:40 Magnet Current, Imag = 449.9300 A Vtrans = 4.499300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:26:42 Magnet Current, Imag = 449.9420 A Vtrans = 4.499420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:26:44 Magnet Current, Imag = 449.9560 A Vtrans = 4.499560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:26:45 Magnet Current, Imag = 449.9340 A Vtrans = 4.499340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:26:45 Magnet Current Measurement: Imag = 449.9405 +- 0.0099 A 13:26:45 Magnet current ramping to 500.0000 A... 13:27:33 Magnet Current, Imag = 500.0100 A Vtrans = 5.000100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:27:35 Magnet Current, Imag = 500.0090 A Vtrans = 5.000090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:27:36 Magnet Current, Imag = 500.0070 A Vtrans = 5.000070 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:27:38 Magnet Current, Imag = 499.9880 A Vtrans = 4.999880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:27:38 Magnet Current Measurement: Imag = 500.0035 +- 0.0090 A 13:27:38 Magnetic Field Measurement Measuring the magnet strength... 13:27:38 Integrated Voltage Measurement... 13:27:55 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.015137930 Vs 13:28:06 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.014658975 Vs 13:28:16 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.015130833 Vs 13:28:27 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.014661636 Vs 13:28:38 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.015117610 Vs 13:28:48 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.014653310 Vs 13:28:59 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.015128496 Vs 13:29:10 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.014659589 Vs 13:29:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.014893547 +- 0.000004923 Vs 13:29:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014893547 +- 0.000004923 Vs BL = 1.48935473 +- 0.00049227 Tm 13:29:16 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.48935 0.00049 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 1.48935 0.00049 1.48935 0.00000 13:29:16 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 1.48935 0.00049 SL = 1.4893547 +- 0.0004923 Tm^2/m^n 13:29:16 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4893547 +- 0.0004923 Tm^2/m^n 13:29:18 Magnet Current, Imag = 499.9860 A Vtrans = 4.999860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:29:20 Magnet Current, Imag = 499.9960 A Vtrans = 4.999960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:29:21 Magnet Current, Imag = 499.9970 A Vtrans = 4.999970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:29:23 Magnet Current, Imag = 499.9910 A Vtrans = 4.999910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:29:23 Magnet Current Measurement: Imag = 499.9925 +- 0.0044 A 13:29:23 Magnet current ramping to 525.0000 A... 13:30:04 Magnet Current, Imag = 524.9950 A Vtrans = 5.249950 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:30:05 Magnet Current, Imag = 524.9790 A Vtrans = 5.249790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:30:07 Magnet Current, Imag = 524.9840 A Vtrans = 5.249840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:30:08 Magnet Current, Imag = 524.9890 A Vtrans = 5.249890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:30:08 Magnet Current Measurement: Imag = 524.9867 +- 0.0059 A 13:30:08 Magnetic Field Measurement Measuring the magnet strength... 13:30:09 Integrated Voltage Measurement... 13:30:25 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.015863988 Vs 13:30:36 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.015395035 Vs 13:30:47 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.015872856 Vs 13:30:57 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.015394603 Vs 13:31:08 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.015871785 Vs 13:31:19 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.015403989 Vs 13:31:29 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.015856946 Vs 13:31:40 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.015378470 Vs 13:31:40 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.015629709 +- 0.000007535 Vs 13:31:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015629709 +- 0.000007535 Vs BL = 1.56297090 +- 0.00075350 Tm 13:31:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.56297 0.00075 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 1.56297 0.00075 1.56297 0.00000 13:31:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 1.56297 0.00075 SL = 1.5629709 +- 0.0007535 Tm^2/m^n 13:31:47 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5629709 +- 0.0007535 Tm^2/m^n 13:31:48 Magnet Current, Imag = 525.0060 A Vtrans = 5.250060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:31:50 Magnet Current, Imag = 524.9870 A Vtrans = 5.249870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:31:51 Magnet Current, Imag = 524.9970 A Vtrans = 5.249970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:31:53 Magnet Current, Imag = 525.0010 A Vtrans = 5.250010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:31:53 Magnet Current Measurement: Imag = 524.9977 +- 0.0070 A 13:31:53 Magnet current ramping to 550.0000 A... 13:32:34 Magnet Current, Imag = 549.9570 A Vtrans = 5.499570 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:32:35 Magnet Current, Imag = 549.9580 A Vtrans = 5.499580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:32:37 Magnet Current, Imag = 549.9410 A Vtrans = 5.499410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:32:39 Magnet Current, Imag = 549.9560 A Vtrans = 5.499560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:32:39 Magnet Current Measurement: Imag = 549.9530 +- 0.0070 A 13:32:39 Magnetic Field Measurement Measuring the magnet strength... 13:32:39 Integrated Voltage Measurement... 13:32:56 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.016591619 Vs 13:33:06 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.016112185 Vs 13:33:17 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.016587145 Vs 13:33:28 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.016117173 Vs 13:33:38 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.016593313 Vs 13:33:49 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.016129150 Vs 13:34:00 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.016594825 Vs 13:34:11 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.016115505 Vs 13:34:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.016355114 +- 0.000003757 Vs 13:34:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016355114 +- 0.000003757 Vs BL = 1.63551144 +- 0.00037574 Tm 13:34:17 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.63551 0.00038 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 1.63551 0.00038 1.63551 0.00000 13:34:17 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 1.63551 0.00038 SL = 1.6355114 +- 0.0003757 Tm^2/m^n 13:34:17 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6355114 +- 0.0003757 Tm^2/m^n 13:34:19 Magnet Current, Imag = 549.9580 A Vtrans = 5.499580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:34:21 Magnet Current, Imag = 549.9540 A Vtrans = 5.499540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:34:22 Magnet Current, Imag = 549.9510 A Vtrans = 5.499510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:34:24 Magnet Current, Imag = 549.9420 A Vtrans = 5.499420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:34:24 Magnet Current Measurement: Imag = 549.9512 +- 0.0059 A 13:34:24 Magnet current ramping to 575.0000 A... 13:35:05 Magnet Current, Imag = 574.9680 A Vtrans = 5.749680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:35:06 Magnet Current, Imag = 574.9880 A Vtrans = 5.749880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:35:08 Magnet Current, Imag = 574.9840 A Vtrans = 5.749840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:35:09 Magnet Current, Imag = 574.9810 A Vtrans = 5.749810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:35:09 Magnet Current Measurement: Imag = 574.9802 +- 0.0075 A 13:35:10 Magnetic Field Measurement Measuring the magnet strength... 13:35:10 Integrated Voltage Measurement... 13:35:26 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.017312339 Vs 13:35:37 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.016842659 Vs 13:35:47 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.017315295 Vs 13:35:58 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.016844505 Vs 13:36:09 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.017309823 Vs 13:36:19 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.016834819 Vs 13:36:30 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.017305167 Vs 13:36:41 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.016837527 Vs 13:36:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.017075267 +- 0.000003553 Vs 13:36:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017075267 +- 0.000003553 Vs BL = 1.70752668 +- 0.00035529 Tm 13:36:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.70753 0.00036 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 1.70753 0.00036 1.70753 0.00000 13:36:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 1.70753 0.00036 SL = 1.7075267 +- 0.0003553 Tm^2/m^n 13:36:48 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7075267 +- 0.0003553 Tm^2/m^n 13:36:49 Magnet Current, Imag = 574.9980 A Vtrans = 5.749980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:36:51 Magnet Current, Imag = 575.0050 A Vtrans = 5.750050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:36:53 Magnet Current, Imag = 575.0090 A Vtrans = 5.750090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:36:54 Magnet Current, Imag = 575.0020 A Vtrans = 5.750020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:36:54 Magnet Current Measurement: Imag = 575.0035 +- 0.0040 A 13:36:54 Magnet current ramping to 600.0000 A... 13:37:35 Magnet Current, Imag = 599.9740 A Vtrans = 5.999740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:37:36 Magnet Current, Imag = 599.9900 A Vtrans = 5.999900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:37:38 Magnet Current, Imag = 599.9900 A Vtrans = 5.999900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:37:40 Magnet Current, Imag = 600.0210 A Vtrans = 6.000210 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:37:40 Magnet Current Measurement: Imag = 599.9937 +- 0.0170 A 13:37:40 Magnetic Field Measurement Measuring the magnet strength... 13:37:40 Integrated Voltage Measurement... 13:37:57 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.018017479 Vs 13:38:07 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.017554232 Vs 13:38:18 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.018017601 Vs 13:38:29 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.017550403 Vs 13:38:39 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.018011661 Vs 13:38:50 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.017550869 Vs 13:39:00 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.018024263 Vs 13:39:11 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.017545005 Vs 13:39:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.017783939 +- 0.000001681 Vs 13:39:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017783939 +- 0.000001681 Vs BL = 1.77839391 +- 0.00016815 Tm 13:39:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.77839 0.00017 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 1.77839 0.00017 1.77839 0.00000 13:39:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 1.77839 0.00017 SL = 1.7783939 +- 0.0001681 Tm^2/m^n 13:39:18 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7783939 +- 0.0001681 Tm^2/m^n 13:39:20 Magnet Current, Imag = 599.9850 A Vtrans = 5.999850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:39:21 Magnet Current, Imag = 599.9750 A Vtrans = 5.999750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:39:23 Magnet Current, Imag = 600.0030 A Vtrans = 6.000030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:39:24 Magnet Current, Imag = 600.0050 A Vtrans = 6.000050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:39:24 Magnet Current Measurement: Imag = 599.9920 +- 0.0125 A 13:39:25 Magnet current ramping to 625.0000 A... 13:40:05 Magnet Current, Imag = 624.9970 A Vtrans = 6.249970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:40:07 Magnet Current, Imag = 625.0020 A Vtrans = 6.250020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:40:08 Magnet Current, Imag = 625.0100 A Vtrans = 6.250100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:40:10 Magnet Current, Imag = 625.0120 A Vtrans = 6.250120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:40:10 Magnet Current Measurement: Imag = 625.0052 +- 0.0061 A 13:40:10 Magnetic Field Measurement Measuring the magnet strength... 13:40:10 Integrated Voltage Measurement... 13:40:27 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.018728545 Vs 13:40:37 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.018238512 Vs 13:40:48 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.018700397 Vs 13:40:59 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.018240807 Vs 13:41:09 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.018706881 Vs 13:41:20 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.018259435 Vs 13:41:31 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.018686358 Vs 13:41:41 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.018241299 Vs 13:41:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.018475279 +- 0.000008413 Vs 13:41:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.018475279 +- 0.000008413 Vs BL = 1.84752791 +- 0.00084132 Tm 13:41:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.84753 0.00084 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 1.84753 0.00084 1.84753 0.00000 13:41:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 1.84753 0.00084 SL = 1.8475279 +- 0.0008413 Tm^2/m^n 13:41:48 Magnet Strength Measurement Harmonic Number = 1 SL = 1.8475279 +- 0.0008413 Tm^2/m^n 13:41:50 Magnet Current, Imag = 625.0110 A Vtrans = 6.250110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:41:51 Magnet Current, Imag = 625.0150 A Vtrans = 6.250150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:41:53 Magnet Current, Imag = 625.0130 A Vtrans = 6.250130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:41:55 Magnet Current, Imag = 625.0160 A Vtrans = 6.250160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:41:55 Magnet Current Measurement: Imag = 625.0137 +- 0.0019 A 13:41:55 Magnet current ramping to 650.0000 A... 13:42:35 Magnet Current, Imag = 650.0520 A Vtrans = 6.500520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:42:37 Magnet Current, Imag = 650.0700 A Vtrans = 6.500700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:42:38 Magnet Current, Imag = 650.0350 A Vtrans = 6.500350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:42:40 Magnet Current, Imag = 650.0340 A Vtrans = 6.500340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:42:40 Magnet Current Measurement: Imag = 650.0478 +- 0.0147 A 13:42:40 Magnetic Field Measurement Measuring the magnet strength... 13:42:40 Integrated Voltage Measurement... 13:42:57 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.019377282 Vs 13:43:08 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.018899775 Vs 13:43:18 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.019378816 Vs 13:43:29 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.018901795 Vs 13:43:40 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.019368282 Vs 13:43:51 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.018895473 Vs 13:44:01 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.019371943 Vs 13:44:12 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.018893195 Vs 13:44:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.019135820 +- 0.000003659 Vs 13:44:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019135820 +- 0.000003659 Vs BL = 1.91358201 +- 0.00036594 Tm 13:44:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.91358 0.00037 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 1.91358 0.00037 1.91358 0.00000 13:44:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 1.91358 0.00037 SL = 1.9135820 +- 0.0003659 Tm^2/m^n 13:44:19 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9135820 +- 0.0003659 Tm^2/m^n 13:44:20 Magnet Current, Imag = 649.9410 A Vtrans = 6.499410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:44:22 Magnet Current, Imag = 650.0040 A Vtrans = 6.500040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:44:24 Magnet Current, Imag = 650.0330 A Vtrans = 6.500330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:44:25 Magnet Current, Imag = 650.0310 A Vtrans = 6.500310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:44:25 Magnet Current Measurement: Imag = 650.0023 +- 0.0372 A 13:44:25 Magnet current ramping to 675.0000 A... 13:45:06 Magnet Current, Imag = 675.0500 A Vtrans = 6.750500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:45:07 Magnet Current, Imag = 675.0330 A Vtrans = 6.750330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:45:09 Magnet Current, Imag = 675.0440 A Vtrans = 6.750440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:45:11 Magnet Current, Imag = 675.0420 A Vtrans = 6.750420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:45:11 Magnet Current Measurement: Imag = 675.0422 +- 0.0061 A 13:45:11 Magnetic Field Measurement Measuring the magnet strength... 13:45:11 Integrated Voltage Measurement... 13:45:27 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.020001074 Vs 13:45:38 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.019528747 Vs 13:45:49 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.019999777 Vs 13:45:59 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.019524986 Vs 13:46:10 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.020008400 Vs 13:46:21 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.019530221 Vs 13:46:31 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.020025409 Vs 13:46:42 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.019526058 Vs 13:46:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.019768084 +- 0.000005065 Vs 13:46:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019768084 +- 0.000005065 Vs BL = 1.97680840 +- 0.00050648 Tm 13:46:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.97681 0.00051 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 1.97681 0.00051 1.97681 0.00000 13:46:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 1.97681 0.00051 SL = 1.9768084 +- 0.0005065 Tm^2/m^n 13:46:49 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9768084 +- 0.0005065 Tm^2/m^n 13:46:51 Magnet Current, Imag = 675.0350 A Vtrans = 6.750350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:46:52 Magnet Current, Imag = 675.0590 A Vtrans = 6.750590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:46:54 Magnet Current, Imag = 675.0540 A Vtrans = 6.750540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:46:55 Magnet Current, Imag = 675.0340 A Vtrans = 6.750340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:46:55 Magnet Current Measurement: Imag = 675.0455 +- 0.0111 A 13:46:55 Magnet current ramping to 700.0000 A... 13:47:36 Magnet Current, Imag = 700.0560 A Vtrans = 7.000560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:47:38 Magnet Current, Imag = 700.0340 A Vtrans = 7.000340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:47:39 Magnet Current, Imag = 700.0090 A Vtrans = 7.000090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:47:41 Magnet Current, Imag = 700.0520 A Vtrans = 7.000520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:47:41 Magnet Current Measurement: Imag = 700.0378 +- 0.0186 A 13:47:41 Magnetic Field Measurement Measuring the magnet strength... 13:47:41 Integrated Voltage Measurement... 13:47:57 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.020583334 Vs 13:48:08 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.020114707 Vs 13:48:19 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.020587870 Vs 13:48:29 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.020110689 Vs 13:48:40 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.020586234 Vs 13:48:51 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.020107515 Vs 13:49:01 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.020583945 Vs 13:49:12 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.020116171 Vs 13:49:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.020348808 +- 0.000001180 Vs 13:49:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020348808 +- 0.000001180 Vs BL = 2.03488081 +- 0.00011798 Tm 13:49:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.03488 0.00012 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 2.03488 0.00012 2.03488 0.00000 13:49:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 2.03488 0.00012 SL = 2.0348808 +- 0.0001180 Tm^2/m^n 13:49:19 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0348808 +- 0.0001180 Tm^2/m^n 13:49:20 Magnet Current, Imag = 700.0460 A Vtrans = 7.000460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:49:22 Magnet Current, Imag = 700.0610 A Vtrans = 7.000610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:49:24 Magnet Current, Imag = 700.0600 A Vtrans = 7.000600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:49:25 Magnet Current, Imag = 700.0560 A Vtrans = 7.000560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:49:25 Magnet Current Measurement: Imag = 700.0557 +- 0.0059 A 13:49:25 Magnet current ramping to 650.0000 A... 13:50:13 Magnet Current, Imag = 650.0110 A Vtrans = 6.500110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:50:15 Magnet Current, Imag = 650.0300 A Vtrans = 6.500300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:50:16 Magnet Current, Imag = 650.0360 A Vtrans = 6.500360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:50:18 Magnet Current, Imag = 650.0350 A Vtrans = 6.500350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:50:18 Magnet Current Measurement: Imag = 650.0280 +- 0.0101 A 13:50:18 Magnetic Field Measurement Measuring the magnet strength... 13:50:18 Integrated Voltage Measurement... 13:50:35 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.019453357 Vs 13:50:45 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.018973267 Vs 13:50:56 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.019455677 Vs 13:51:07 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.018972063 Vs 13:51:18 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.019438087 Vs 13:51:28 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.018969301 Vs 13:51:39 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.019446200 Vs 13:51:50 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.018971714 Vs 13:51:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.019209958 +- 0.000004086 Vs 13:51:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019209958 +- 0.000004086 Vs BL = 1.92099583 +- 0.00040863 Tm 13:51:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.92100 0.00041 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 1.92100 0.00041 1.92100 0.00000 13:51:57 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 1.92100 0.00041 SL = 1.9209958 +- 0.0004086 Tm^2/m^n 13:51:57 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9209958 +- 0.0004086 Tm^2/m^n 13:51:58 Magnet Current, Imag = 650.0160 A Vtrans = 6.500160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:52:00 Magnet Current, Imag = 650.0220 A Vtrans = 6.500220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:52:01 Magnet Current, Imag = 650.0240 A Vtrans = 6.500240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:52:03 Magnet Current, Imag = 650.0540 A Vtrans = 6.500540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:52:03 Magnet Current Measurement: Imag = 650.0290 +- 0.0147 A 13:52:03 Magnet current ramping to 600.0000 A... 13:52:51 Magnet Current, Imag = 600.0220 A Vtrans = 6.000220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:52:53 Magnet Current, Imag = 600.0350 A Vtrans = 6.000350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:52:54 Magnet Current, Imag = 600.0350 A Vtrans = 6.000350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:52:56 Magnet Current, Imag = 600.0390 A Vtrans = 6.000390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:52:56 Magnet Current Measurement: Imag = 600.0327 +- 0.0064 A 13:52:56 Magnetic Field Measurement Measuring the magnet strength... 13:52:56 Integrated Voltage Measurement... 13:53:13 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.018093371 Vs 13:53:23 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.017623273 Vs 13:53:34 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.018100780 Vs 13:53:45 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.017624941 Vs 13:53:55 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.018082195 Vs 13:54:06 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.017622443 Vs 13:54:16 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.018090400 Vs 13:54:27 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.017621583 Vs 13:54:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.017857373 +- 0.000003823 Vs 13:54:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017857373 +- 0.000003823 Vs BL = 1.78573733 +- 0.00038232 Tm 13:54:34 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.78574 0.00038 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 1.78574 0.00038 1.78574 0.00000 13:54:34 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 1.78574 0.00038 SL = 1.7857373 +- 0.0003823 Tm^2/m^n 13:54:34 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7857373 +- 0.0003823 Tm^2/m^n 13:54:36 Magnet Current, Imag = 599.9760 A Vtrans = 5.999760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:54:37 Magnet Current, Imag = 599.9830 A Vtrans = 5.999830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:54:39 Magnet Current, Imag = 600.0090 A Vtrans = 6.000090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:54:41 Magnet Current, Imag = 600.0050 A Vtrans = 6.000050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:54:41 Magnet Current Measurement: Imag = 599.9932 +- 0.0140 A 13:54:41 Magnet current ramping to 550.0000 A... 13:55:29 Magnet Current, Imag = 549.9520 A Vtrans = 5.499520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:30 Magnet Current, Imag = 549.9310 A Vtrans = 5.499310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:32 Magnet Current, Imag = 549.9310 A Vtrans = 5.499310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:33 Magnet Current, Imag = 549.9500 A Vtrans = 5.499500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:33 Magnet Current Measurement: Imag = 549.9410 +- 0.0100 A 13:55:34 Magnetic Field Measurement Measuring the magnet strength... 13:55:34 Integrated Voltage Measurement... 13:55:50 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.016664607 Vs 13:56:01 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.016181609 Vs 13:56:12 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.016659763 Vs 13:56:22 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.016188659 Vs 13:56:33 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.016661079 Vs 13:56:43 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.016187865 Vs 13:56:54 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.016661321 Vs 13:57:05 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.016183983 Vs 13:57:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.016423611 +- 0.000000754 Vs 13:57:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016423611 +- 0.000000754 Vs BL = 1.64236107 +- 0.00007540 Tm 13:57:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.64236 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 1.64236 0.00008 1.64236 0.00000 13:57:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 1.64236 0.00008 SL = 1.6423611 +- 0.0000754 Tm^2/m^n 13:57:12 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6423611 +- 0.0000754 Tm^2/m^n 13:57:13 Magnet Current, Imag = 549.9600 A Vtrans = 5.499600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:57:15 Magnet Current, Imag = 549.9690 A Vtrans = 5.499690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:57:16 Magnet Current, Imag = 549.9640 A Vtrans = 5.499640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:57:18 Magnet Current, Imag = 549.9550 A Vtrans = 5.499550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:57:18 Magnet Current Measurement: Imag = 549.9620 +- 0.0051 A 13:57:18 Magnet current ramping to 500.0000 A... 13:58:06 Magnet Current, Imag = 499.9860 A Vtrans = 4.999860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:58:08 Magnet Current, Imag = 499.9830 A Vtrans = 4.999830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:58:09 Magnet Current, Imag = 499.9750 A Vtrans = 4.999750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:58:11 Magnet Current, Imag = 499.9690 A Vtrans = 4.999690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:58:11 Magnet Current Measurement: Imag = 499.9783 +- 0.0067 A 13:58:11 Magnetic Field Measurement Measuring the magnet strength... 13:58:11 Integrated Voltage Measurement... 13:58:28 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.015180437 Vs 13:58:38 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.014700907 Vs 13:58:49 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.015184460 Vs 13:59:00 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.014706801 Vs 13:59:10 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.015183291 Vs 13:59:21 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.014709228 Vs 13:59:31 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.015189283 Vs 13:59:42 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.014709571 Vs 13:59:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.014945497 +- 0.000003135 Vs 13:59:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014945497 +- 0.000003135 Vs BL = 1.49454972 +- 0.00031355 Tm 13:59:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.49455 0.00031 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 1.49455 0.00031 1.49455 0.00000 13:59:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 1.49455 0.00031 SL = 1.4945497 +- 0.0003135 Tm^2/m^n 13:59:49 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4945497 +- 0.0003135 Tm^2/m^n 13:59:50 Magnet Current, Imag = 499.9830 A Vtrans = 4.999830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:59:52 Magnet Current, Imag = 499.9890 A Vtrans = 4.999890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:59:54 Magnet Current, Imag = 499.9850 A Vtrans = 4.999850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:59:55 Magnet Current, Imag = 499.9830 A Vtrans = 4.999830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:59:55 Magnet Current Measurement: Imag = 499.9850 +- 0.0024 A 13:59:55 Magnet current ramping to 450.0000 A... 14:00:43 Magnet Current, Imag = 449.9120 A Vtrans = 4.499120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:00:45 Magnet Current, Imag = 449.9240 A Vtrans = 4.499240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:00:46 Magnet Current, Imag = 449.9320 A Vtrans = 4.499320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:00:48 Magnet Current, Imag = 449.9120 A Vtrans = 4.499120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:00:48 Magnet Current Measurement: Imag = 449.9200 +- 0.0085 A 14:00:48 Magnetic Field Measurement Measuring the magnet strength... 14:00:48 Integrated Voltage Measurement... 14:01:05 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.013688377 Vs 14:01:16 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.013218806 Vs 14:01:26 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.013705087 Vs 14:01:37 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.013225596 Vs 14:01:48 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.013703499 Vs 14:01:58 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.013232245 Vs 14:02:09 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.013695807 Vs 14:02:19 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.013227383 Vs 14:02:19 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.013462100 +- 0.000005396 Vs 14:02:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.013462100 +- 0.000005396 Vs BL = 1.34620999 +- 0.00053962 Tm 14:02:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.34621 0.00054 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 1.34621 0.00054 1.34621 0.00000 14:02:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 1.34621 0.00054 SL = 1.3462100 +- 0.0005396 Tm^2/m^n 14:02:26 Magnet Strength Measurement Harmonic Number = 1 SL = 1.3462100 +- 0.0005396 Tm^2/m^n 14:02:28 Magnet Current, Imag = 449.9250 A Vtrans = 4.499250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:02:29 Magnet Current, Imag = 449.9280 A Vtrans = 4.499280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:02:31 Magnet Current, Imag = 449.9500 A Vtrans = 4.499500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:02:33 Magnet Current, Imag = 449.9380 A Vtrans = 4.499380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:02:33 Magnet Current Measurement: Imag = 449.9352 +- 0.0098 A 14:02:33 Magnet current ramping to 400.0000 A... 14:03:21 Magnet Current, Imag = 399.8840 A Vtrans = 3.998840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:03:22 Magnet Current, Imag = 399.8900 A Vtrans = 3.998900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:03:24 Magnet Current, Imag = 399.9070 A Vtrans = 3.999070 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:03:25 Magnet Current, Imag = 399.8930 A Vtrans = 3.998930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:03:25 Magnet Current Measurement: Imag = 399.8935 +- 0.0084 A 14:03:26 Magnetic Field Measurement Measuring the magnet strength... 14:03:26 Integrated Voltage Measurement... 14:03:42 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.012208938 Vs 14:03:53 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.011749255 Vs 14:04:04 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.012214213 Vs 14:04:14 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.011731651 Vs 14:04:25 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.012205968 Vs 14:04:36 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.011737730 Vs 14:04:46 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.012214238 Vs 14:04:57 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.011741223 Vs 14:04:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.011975402 +- 0.000003074 Vs 14:04:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.011975402 +- 0.000003074 Vs BL = 1.19754018 +- 0.00030739 Tm 14:05:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.19754 0.00031 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 1.19754 0.00031 1.19754 0.00000 14:05:04 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 1.19754 0.00031 SL = 1.1975402 +- 0.0003074 Tm^2/m^n 14:05:04 Magnet Strength Measurement Harmonic Number = 1 SL = 1.1975402 +- 0.0003074 Tm^2/m^n 14:05:05 Magnet Current, Imag = 399.9070 A Vtrans = 3.999070 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:05:07 Magnet Current, Imag = 399.9020 A Vtrans = 3.999020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:05:08 Magnet Current, Imag = 399.9020 A Vtrans = 3.999020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:05:10 Magnet Current, Imag = 399.8820 A Vtrans = 3.998820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:05:10 Magnet Current Measurement: Imag = 399.8982 +- 0.0096 A 14:05:10 Magnet current ramping to 350.0000 A... 14:05:59 Magnet Current, Imag = 349.8980 A Vtrans = 3.498980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:01 Magnet Current, Imag = 349.8990 A Vtrans = 3.498990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:02 Magnet Current, Imag = 349.9140 A Vtrans = 3.499140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:04 Magnet Current, Imag = 349.9240 A Vtrans = 3.499240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:04 Magnet Current Measurement: Imag = 349.9087 +- 0.0108 A 14:06:05 Magnetic Field Measurement Measuring the magnet strength... 14:06:05 Integrated Voltage Measurement... 14:06:21 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.010720564 Vs 14:06:32 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.010248100 Vs 14:06:43 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.010721297 Vs 14:06:53 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.010237784 Vs 14:07:04 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.010720425 Vs 14:07:15 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.010248105 Vs 14:07:25 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.010720723 Vs 14:07:36 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.010249128 Vs 14:07:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.010483266 +- 0.000002166 Vs 14:07:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.010483266 +- 0.000002166 Vs BL = 1.04832657 +- 0.00021660 Tm 14:07:43 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.04833 0.00022 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 1.04833 0.00022 1.04833 0.00000 14:07:43 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 1.04833 0.00022 SL = 1.0483266 +- 0.0002166 Tm^2/m^n 14:07:43 Magnet Strength Measurement Harmonic Number = 1 SL = 1.0483266 +- 0.0002166 Tm^2/m^n 14:07:45 Magnet Current, Imag = 349.9250 A Vtrans = 3.499250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:07:47 Magnet Current, Imag = 349.9020 A Vtrans = 3.499020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:07:49 Magnet Current, Imag = 349.9090 A Vtrans = 3.499090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:07:50 Magnet Current, Imag = 349.9000 A Vtrans = 3.499000 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:07:51 Magnet Current Measurement: Imag = 349.9090 +- 0.0098 A 14:07:51 Magnet current ramping to 300.0000 A... 14:08:39 Magnet Current, Imag = 299.8692 A Vtrans = 2.998692 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:41 Magnet Current, Imag = 299.8652 A Vtrans = 2.998652 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:42 Magnet Current, Imag = 299.8721 A Vtrans = 2.998721 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:44 Magnet Current, Imag = 299.8606 A Vtrans = 2.998606 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:44 Magnet Current Measurement: Imag = 299.8668 +- 0.0043 A 14:08:44 Magnetic Field Measurement Measuring the magnet strength... 14:08:44 Integrated Voltage Measurement... 14:09:01 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.009233683 Vs 14:09:11 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.008749330 Vs 14:09:22 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.009229451 Vs 14:09:32 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.008755470 Vs 14:09:43 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.009223197 Vs 14:09:54 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.008754371 Vs 14:10:04 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.009216723 Vs 14:10:15 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.008750051 Vs 14:10:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.008989034 +- 0.000003529 Vs 14:10:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.008989034 +- 0.000003529 Vs BL = 0.89890345 +- 0.00035286 Tm 14:10:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.89890 0.00035 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 0.89890 0.00035 0.89890 0.00000 14:10:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 0.89890 0.00035 SL = 0.8989034 +- 0.0003529 Tm^2/m^n 14:10:22 Magnet Strength Measurement Harmonic Number = 1 SL = 0.8989034 +- 0.0003529 Tm^2/m^n 14:10:23 Magnet Current, Imag = 299.8647 A Vtrans = 2.998647 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:10:25 Magnet Current, Imag = 299.8524 A Vtrans = 2.998524 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:10:26 Magnet Current, Imag = 299.8553 A Vtrans = 2.998553 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:10:28 Magnet Current, Imag = 299.8433 A Vtrans = 2.998433 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:10:28 Magnet Current Measurement: Imag = 299.8539 +- 0.0076 A 14:10:28 Magnet current ramping to 250.0000 A... 14:11:16 Magnet Current, Imag = 249.8393 A Vtrans = 2.498393 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:17 Magnet Current, Imag = 249.8349 A Vtrans = 2.498349 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:19 Magnet Current, Imag = 249.8498 A Vtrans = 2.498498 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:20 Magnet Current, Imag = 249.8530 A Vtrans = 2.498530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:20 Magnet Current Measurement: Imag = 249.8442 +- 0.0074 A 14:11:20 Magnetic Field Measurement Measuring the magnet strength... 14:11:20 Integrated Voltage Measurement... 14:11:37 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.007733033 Vs 14:11:48 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.007256731 Vs 14:11:58 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.007730167 Vs 14:12:09 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.007258093 Vs 14:12:20 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.007722049 Vs 14:12:30 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.007262519 Vs 14:12:41 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.007736497 Vs 14:12:52 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.007270140 Vs 14:12:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.007496154 +- 0.000004243 Vs 14:12:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.007496154 +- 0.000004243 Vs BL = 0.74961536 +- 0.00042434 Tm 14:12:58 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.74962 0.00042 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 0.74962 0.00042 0.74962 0.00000 14:12:58 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 0.74962 0.00042 SL = 0.7496154 +- 0.0004243 Tm^2/m^n 14:12:58 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7496154 +- 0.0004243 Tm^2/m^n 14:13:00 Magnet Current, Imag = 249.8241 A Vtrans = 2.498241 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:01 Magnet Current, Imag = 249.8417 A Vtrans = 2.498417 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:03 Magnet Current, Imag = 249.8379 A Vtrans = 2.498379 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:04 Magnet Current, Imag = 249.8469 A Vtrans = 2.498469 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:04 Magnet Current Measurement: Imag = 249.8376 +- 0.0085 A 14:13:05 Magnet current ramping to 200.0000 A... 14:13:52 Magnet Current, Imag = 199.8160 A Vtrans = 1.998160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:54 Magnet Current, Imag = 199.8098 A Vtrans = 1.998098 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:55 Magnet Current, Imag = 199.8095 A Vtrans = 1.998095 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:57 Magnet Current, Imag = 199.8261 A Vtrans = 1.998261 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:57 Magnet Current Measurement: Imag = 199.8153 +- 0.0067 A 14:13:57 Magnetic Field Measurement Measuring the magnet strength... 14:13:57 Integrated Voltage Measurement... 14:14:14 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.006231826 Vs 14:14:24 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.005760563 Vs 14:14:35 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.006232228 Vs 14:14:45 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.005754387 Vs 14:14:56 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.006245782 Vs 14:15:07 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.005761438 Vs 14:15:17 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.006242446 Vs 14:15:28 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.005774482 Vs 14:15:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.006000394 +- 0.000005986 Vs 14:15:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006000394 +- 0.000005986 Vs BL = 0.60003940 +- 0.00059859 Tm 14:15:35 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.60004 0.00060 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 0.60004 0.00060 0.60004 0.00000 14:15:35 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 0.60004 0.00060 SL = 0.6000394 +- 0.0005986 Tm^2/m^n 14:15:35 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6000394 +- 0.0005986 Tm^2/m^n 14:15:36 Magnet Current, Imag = 199.8190 A Vtrans = 1.998190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:38 Magnet Current, Imag = 199.8080 A Vtrans = 1.998080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:39 Magnet Current, Imag = 199.7958 A Vtrans = 1.997958 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:41 Magnet Current, Imag = 199.8102 A Vtrans = 1.998102 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:41 Magnet Current Measurement: Imag = 199.8082 +- 0.0083 A 14:15:41 Magnet current ramping to 150.0000 A... 14:16:29 Magnet Current, Imag = 149.8468 A Vtrans = 1.498468 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:16:31 Magnet Current, Imag = 149.8409 A Vtrans = 1.498409 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:16:32 Magnet Current, Imag = 149.8238 A Vtrans = 1.498238 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:16:34 Magnet Current, Imag = 149.8216 A Vtrans = 1.498216 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:16:34 Magnet Current Measurement: Imag = 149.8333 +- 0.0108 A 14:16:34 Magnetic Field Measurement Measuring the magnet strength... 14:16:34 Integrated Voltage Measurement... 14:16:50 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.004749845 Vs 14:17:01 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.004263870 Vs 14:17:12 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.004741659 Vs 14:17:22 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.004271222 Vs 14:17:33 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.004751651 Vs 14:17:44 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.004269638 Vs 14:17:54 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.004746931 Vs 14:18:05 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.004272761 Vs 14:18:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.004508447 +- 0.000001826 Vs 14:18:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004508447 +- 0.000001826 Vs BL = 0.45084471 +- 0.00018261 Tm 14:18:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.45084 0.00018 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 0.45084 0.00018 0.45084 0.00000 14:18:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 0.45084 0.00018 SL = 0.4508447 +- 0.0001826 Tm^2/m^n 14:18:12 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4508447 +- 0.0001826 Tm^2/m^n 14:18:13 Magnet Current, Imag = 149.8111 A Vtrans = 1.498111 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:18:15 Magnet Current, Imag = 149.8140 A Vtrans = 1.498140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:18:16 Magnet Current, Imag = 149.8108 A Vtrans = 1.498108 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:18:18 Magnet Current, Imag = 149.8254 A Vtrans = 1.498254 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:18:18 Magnet Current Measurement: Imag = 149.8153 +- 0.0059 A 14:18:18 Magnet current ramping to 100.0000 A... 14:19:05 Magnet Current, Imag = 99.8022 A Vtrans = 0.998022 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:07 Magnet Current, Imag = 99.7969 A Vtrans = 0.997969 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:08 Magnet Current, Imag = 99.7666 A Vtrans = 0.997666 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:10 Magnet Current, Imag = 99.8090 A Vtrans = 0.998090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:10 Magnet Current Measurement: Imag = 99.7937 +- 0.0162 A 14:19:10 Magnetic Field Measurement Measuring the magnet strength... 14:19:10 Integrated Voltage Measurement... 14:19:27 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.003244793 Vs 14:19:37 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.002775919 Vs 14:19:48 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.003250127 Vs 14:19:59 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.002778463 Vs 14:20:09 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.003252346 Vs 14:20:20 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.002779790 Vs 14:20:30 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.003244253 Vs 14:20:41 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.002780070 Vs 14:20:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.003013220 +- 0.000002156 Vs 14:20:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.003013220 +- 0.000002156 Vs BL = 0.30132202 +- 0.00021558 Tm 14:20:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.30132 0.00022 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 0.30132 0.00022 0.30132 0.00000 14:20:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 0.30132 0.00022 SL = 0.3013220 +- 0.0002156 Tm^2/m^n 14:20:48 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3013220 +- 0.0002156 Tm^2/m^n 14:20:50 Magnet Current, Imag = 99.7863 A Vtrans = 0.997863 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:20:51 Magnet Current, Imag = 99.7778 A Vtrans = 0.997778 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:20:52 Magnet Current, Imag = 99.7895 A Vtrans = 0.997895 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:20:54 Magnet Current, Imag = 99.7964 A Vtrans = 0.997964 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:20:54 Magnet Current Measurement: Imag = 99.7875 +- 0.0067 A 14:20:54 Magnet current ramping to 50.0000 A... 14:21:42 Magnet Current, Imag = 49.7511 A Vtrans = 0.497511 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:43 Magnet Current, Imag = 49.7600 A Vtrans = 0.497600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:45 Magnet Current, Imag = 49.7709 A Vtrans = 0.497709 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:46 Magnet Current, Imag = 49.7661 A Vtrans = 0.497661 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:46 Magnet Current Measurement: Imag = 49.7620 +- 0.0074 A 14:21:46 Magnetic Field Measurement Measuring the magnet strength... 14:21:46 Integrated Voltage Measurement... 14:22:03 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.001754581 Vs 14:22:14 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.001280405 Vs 14:22:24 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.001755496 Vs 14:22:35 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.001277086 Vs 14:22:45 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.001757473 Vs 14:22:56 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.001271393 Vs 14:23:07 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.001746861 Vs 14:23:17 Integrated Voltage Measurement X0 = 0.0244510 m, Delta X = -0.0100000 m VT = -0.001280532 Vs 14:23:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0244510 m, Delta X = 0.0100000 m VT = 0.001515478 +- 0.000001499 Vs 14:23:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0244510 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001515478 +- 0.000001499 Vs BL = 0.15154785 +- 0.00014990 Tm 14:23:24 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.15155 0.00015 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.024451 0.15155 0.00015 0.15155 0.00000 14:23:24 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0245 0.15155 0.00015 SL = 0.1515478 +- 0.0001499 Tm^2/m^n 14:23:24 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1515478 +- 0.0001499 Tm^2/m^n 14:23:26 Magnet Current, Imag = 49.7736 A Vtrans = 0.497736 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:23:27 Magnet Current, Imag = 49.7900 A Vtrans = 0.497900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:23:28 Magnet Current, Imag = 49.7670 A Vtrans = 0.497670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:23:30 Magnet Current, Imag = 49.7664 A Vtrans = 0.497664 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:23:30 Magnet Current Measurement: Imag = 49.7743 +- 0.0095 A 14:24:01 Magnet current ramping to 0.0000 A...