SLAC Magnetic Measurements Date: 10-17-2001 Time: 11:58:45 Project: spear3 Magnet Type: gdipole Magnet Name: 145d-027 Serial Number: Run Number: 11 Measurement Device: stretched wire Operator: jy Comment: redo BL v. I, main Standardization: 1 cycles from 0.0 A to 770.0 A to 0.0 A Test Currents (A): 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 500.0 525.0 550.0 575.0 600.0 625.0 650.0 675.0 700.0 650.0 600.0 550.0 500.0 450.0 400.0 11:58:51 Initial Zero Current Measurement, Imag_zero = 0.0000 A 11:58:51 Magnet current ramping to 15.0000 A... 11:59:22 Magnet current ramping to 770.0000 A... 12:03:39 Magnet current ramping to 0.0000 A... 12:08:27 Magnet current ramping to 50.0000 A... 12:08:50 Magnet Current, Imag = 36.3119 A Vtrans = 0.363119 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:08:52 Magnet Current, Imag = 48.4782 A Vtrans = 0.484782 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:08:53 Magnet Current, Imag = 54.3554 A Vtrans = 0.543554 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:08:54 Magnet Current, Imag = 47.1981 A Vtrans = 0.471981 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:08:54 Magnet Current Measurement: Imag = 46.5859 +- 6.5168 A 12:08:55 Magnetic Field Measurement Measuring the magnet strength... 12:08:55 Integrated Voltage Measurement... 12:09:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001416445 Vs 12:09:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001598517 Vs 12:09:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001596859 Vs 12:09:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001596695 Vs 12:09:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001597307 Vs 12:10:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001599533 Vs 12:10:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001594989 Vs 12:10:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001598998 Vs 12:10:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001574918 +- 0.000038940 Vs 12:10:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001574918 +- 0.000038940 Vs BL = 0.15749179 +- 0.00389398 Tm 12:10:24 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.15749 0.00389 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.15749 0.00389 0.15749 0.00000 12:10:24 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.15749 0.00389 SL = 0.1574918 +- 0.0038940 Tm^2/m^n 12:10:24 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1574918 +- 0.0038940 Tm^2/m^n 12:10:25 Magnet Current, Imag = 49.6013 A Vtrans = 0.496013 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:10:27 Magnet Current, Imag = 49.5805 A Vtrans = 0.495805 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:10:28 Magnet Current, Imag = 49.5913 A Vtrans = 0.495913 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:10:30 Magnet Current, Imag = 49.6082 A Vtrans = 0.496082 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:10:30 Magnet Current Measurement: Imag = 49.5953 +- 0.0105 A 12:10:30 Magnet current ramping to 100.0000 A... 12:10:52 Magnet Current, Imag = 99.6576 A Vtrans = 0.996576 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:10:54 Magnet Current, Imag = 99.6495 A Vtrans = 0.996495 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:10:55 Magnet Current, Imag = 99.6338 A Vtrans = 0.996338 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:10:57 Magnet Current, Imag = 99.6570 A Vtrans = 0.996570 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:10:57 Magnet Current Measurement: Imag = 99.6495 +- 0.0096 A 12:10:57 Magnetic Field Measurement Measuring the magnet strength... 12:10:57 Integrated Voltage Measurement... 12:11:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003169281 Vs 12:11:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003168785 Vs 12:11:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003175100 Vs 12:11:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003175027 Vs 12:11:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003174686 Vs 12:12:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003169303 Vs 12:12:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003182441 Vs 12:12:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003163201 Vs 12:12:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003172228 +- 0.000002160 Vs 12:12:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.003172228 +- 0.000002160 Vs BL = 0.31722279 +- 0.00021596 Tm 12:12:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.31722 0.00022 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.31722 0.00022 0.31722 0.00000 12:12:27 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.31722 0.00022 SL = 0.3172228 +- 0.0002160 Tm^2/m^n 12:12:27 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3172228 +- 0.0002160 Tm^2/m^n 12:12:28 Magnet Current, Imag = 99.6450 A Vtrans = 0.996450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:12:30 Magnet Current, Imag = 99.6513 A Vtrans = 0.996513 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:12:31 Magnet Current, Imag = 99.6591 A Vtrans = 0.996591 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:12:32 Magnet Current, Imag = 99.6289 A Vtrans = 0.996289 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:12:32 Magnet Current Measurement: Imag = 99.6461 +- 0.0111 A 12:12:32 Magnet current ramping to 150.0000 A... 12:12:56 Magnet Current, Imag = 149.7232 A Vtrans = 1.497232 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:12:57 Magnet Current, Imag = 149.6958 A Vtrans = 1.496958 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:12:58 Magnet Current, Imag = 149.7041 A Vtrans = 1.497041 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:13:00 Magnet Current, Imag = 149.6895 A Vtrans = 1.496895 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:13:00 Magnet Current Measurement: Imag = 149.7031 +- 0.0127 A 12:13:00 Magnetic Field Measurement Measuring the magnet strength... 12:13:00 Integrated Voltage Measurement... 12:13:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004759879 Vs 12:13:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004762739 Vs 12:13:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004766753 Vs 12:13:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004764257 Vs 12:13:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004763539 Vs 12:14:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004761735 Vs 12:14:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004765858 Vs 12:14:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004757642 Vs 12:14:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004762800 +- 0.000001633 Vs 12:14:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004762800 +- 0.000001633 Vs BL = 0.47628003 +- 0.00016331 Tm 12:14:30 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.47628 0.00016 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.47628 0.00016 0.47628 0.00000 12:14:30 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.47628 0.00016 SL = 0.4762800 +- 0.0001633 Tm^2/m^n 12:14:30 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4762800 +- 0.0001633 Tm^2/m^n 12:14:31 Magnet Current, Imag = 149.6932 A Vtrans = 1.496932 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:14:33 Magnet Current, Imag = 149.6984 A Vtrans = 1.496984 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:14:34 Magnet Current, Imag = 149.6914 A Vtrans = 1.496914 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:14:36 Magnet Current, Imag = 149.6992 A Vtrans = 1.496992 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:14:36 Magnet Current Measurement: Imag = 149.6955 +- 0.0033 A 12:14:36 Magnet current ramping to 200.0000 A... 12:14:58 Magnet Current, Imag = 199.7264 A Vtrans = 1.997264 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:15:00 Magnet Current, Imag = 199.7184 A Vtrans = 1.997184 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:15:01 Magnet Current, Imag = 199.7064 A Vtrans = 1.997064 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:15:03 Magnet Current, Imag = 199.7135 A Vtrans = 1.997135 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:15:03 Magnet Current Measurement: Imag = 199.7162 +- 0.0073 A 12:15:03 Magnetic Field Measurement Measuring the magnet strength... 12:15:03 Integrated Voltage Measurement... 12:15:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006358236 Vs 12:15:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006349738 Vs 12:15:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006367710 Vs 12:15:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006348970 Vs 12:15:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006369373 Vs 12:16:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006340766 Vs 12:16:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006355706 Vs 12:16:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006365814 Vs 12:16:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006357039 +- 0.000002680 Vs 12:16:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006357039 +- 0.000002680 Vs BL = 0.63570392 +- 0.00026801 Tm 12:16:33 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.63570 0.00027 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.63570 0.00027 0.63570 0.00000 12:16:33 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.63570 0.00027 SL = 0.6357039 +- 0.0002680 Tm^2/m^n 12:16:33 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6357039 +- 0.0002680 Tm^2/m^n 12:16:34 Magnet Current, Imag = 199.7216 A Vtrans = 1.997216 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:16:36 Magnet Current, Imag = 199.7203 A Vtrans = 1.997203 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:16:37 Magnet Current, Imag = 199.7287 A Vtrans = 1.997287 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:16:38 Magnet Current, Imag = 199.7379 A Vtrans = 1.997379 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:16:38 Magnet Current Measurement: Imag = 199.7271 +- 0.0070 A 12:16:39 Magnet current ramping to 250.0000 A... 12:17:02 Magnet Current, Imag = 249.7550 A Vtrans = 2.497550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:17:03 Magnet Current, Imag = 249.7682 A Vtrans = 2.497682 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:17:05 Magnet Current, Imag = 249.7898 A Vtrans = 2.497898 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:17:06 Magnet Current, Imag = 249.7944 A Vtrans = 2.497944 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:17:06 Magnet Current Measurement: Imag = 249.7768 +- 0.0160 A 12:17:06 Magnetic Field Measurement Measuring the magnet strength... 12:17:06 Integrated Voltage Measurement... 12:17:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007956095 Vs 12:17:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007960946 Vs 12:17:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007955710 Vs 12:17:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007958838 Vs 12:18:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007959871 Vs 12:18:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007951499 Vs 12:18:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007962323 Vs 12:18:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007961245 Vs 12:18:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007958316 +- 0.000002240 Vs 12:18:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.007958316 +- 0.000002240 Vs BL = 0.79583158 +- 0.00022405 Tm 12:18:36 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.79583 0.00022 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.79583 0.00022 0.79583 0.00000 12:18:36 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.79583 0.00022 SL = 0.7958316 +- 0.0002240 Tm^2/m^n 12:18:36 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7958316 +- 0.0002240 Tm^2/m^n 12:18:38 Magnet Current, Imag = 249.7850 A Vtrans = 2.497850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:18:39 Magnet Current, Imag = 249.8011 A Vtrans = 2.498011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:18:40 Magnet Current, Imag = 249.7867 A Vtrans = 2.497867 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:18:42 Magnet Current, Imag = 249.7795 A Vtrans = 2.497795 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:18:42 Magnet Current Measurement: Imag = 249.7881 +- 0.0080 A 12:18:42 Magnet current ramping to 300.0000 A... 12:19:05 Magnet Current, Imag = 299.8233 A Vtrans = 2.998233 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:19:06 Magnet Current, Imag = 299.8414 A Vtrans = 2.998414 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:19:08 Magnet Current, Imag = 299.8395 A Vtrans = 2.998395 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:19:09 Magnet Current, Imag = 299.8386 A Vtrans = 2.998386 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:19:09 Magnet Current Measurement: Imag = 299.8357 +- 0.0072 A 12:19:09 Magnetic Field Measurement Measuring the magnet strength... 12:19:09 Integrated Voltage Measurement... 12:19:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009550405 Vs 12:19:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009546689 Vs 12:19:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009556301 Vs 12:19:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009540045 Vs 12:20:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009552281 Vs 12:20:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009546256 Vs 12:20:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009568414 Vs 12:20:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009541935 Vs 12:20:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009550291 +- 0.000002847 Vs 12:20:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009550291 +- 0.000002847 Vs BL = 0.95502908 +- 0.00028469 Tm 12:20:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.95503 0.00028 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.95503 0.00028 0.95503 0.00000 12:20:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.95503 0.00028 SL = 0.9550291 +- 0.0002847 Tm^2/m^n 12:20:38 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9550291 +- 0.0002847 Tm^2/m^n 12:20:40 Magnet Current, Imag = 299.8340 A Vtrans = 2.998340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:20:42 Magnet Current, Imag = 299.8344 A Vtrans = 2.998344 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:20:43 Magnet Current, Imag = 299.8426 A Vtrans = 2.998426 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:20:45 Magnet Current, Imag = 299.8334 A Vtrans = 2.998334 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:20:45 Magnet Current Measurement: Imag = 299.8361 +- 0.0038 A 12:20:45 Magnet current ramping to 350.0000 A... 12:21:08 Magnet Current, Imag = 349.8940 A Vtrans = 3.498940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:21:10 Magnet Current, Imag = 349.8990 A Vtrans = 3.498990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:21:12 Magnet Current, Imag = 349.9110 A Vtrans = 3.499110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:21:13 Magnet Current, Imag = 349.9290 A Vtrans = 3.499290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:21:14 Magnet Current Measurement: Imag = 349.9083 +- 0.0135 A 12:21:14 Magnetic Field Measurement Measuring the magnet strength... 12:21:14 Integrated Voltage Measurement... 12:21:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011144338 Vs 12:21:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011147915 Vs 12:21:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011148763 Vs 12:21:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011132658 Vs 12:22:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011138142 Vs 12:22:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011142920 Vs 12:22:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011145483 Vs 12:22:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011127664 Vs 12:22:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011140985 +- 0.000003398 Vs 12:22:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.011140985 +- 0.000003398 Vs BL = 1.11409853 +- 0.00033976 Tm 12:22:44 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.11410 0.00034 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.11410 0.00034 1.11410 0.00000 12:22:44 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.11410 0.00034 SL = 1.1140985 +- 0.0003398 Tm^2/m^n 12:22:44 Magnet Strength Measurement Harmonic Number = 1 SL = 1.1140985 +- 0.0003398 Tm^2/m^n 12:22:46 Magnet Current, Imag = 349.9220 A Vtrans = 3.499220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:22:48 Magnet Current, Imag = 349.8970 A Vtrans = 3.498970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:22:50 Magnet Current, Imag = 349.9020 A Vtrans = 3.499020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:22:51 Magnet Current, Imag = 349.9120 A Vtrans = 3.499120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:22:51 Magnet Current Measurement: Imag = 349.9083 +- 0.0096 A 12:22:52 Magnet current ramping to 400.0000 A... 12:23:16 Magnet Current, Imag = 399.9310 A Vtrans = 3.999310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:23:17 Magnet Current, Imag = 399.9330 A Vtrans = 3.999330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:23:19 Magnet Current, Imag = 399.9430 A Vtrans = 3.999430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:23:20 Magnet Current, Imag = 399.9420 A Vtrans = 3.999420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:23:20 Magnet Current Measurement: Imag = 399.9373 +- 0.0053 A 12:23:20 Magnetic Field Measurement Measuring the magnet strength... 12:23:20 Integrated Voltage Measurement... 12:23:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012736949 Vs 12:23:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012736285 Vs 12:23:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012738304 Vs 12:24:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012736805 Vs 12:24:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012734280 Vs 12:24:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012737734 Vs 12:24:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012724495 Vs 12:24:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012733031 Vs 12:24:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012734736 +- 0.000003492 Vs 12:24:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012734736 +- 0.000003492 Vs BL = 1.27347355 +- 0.00034918 Tm 12:24:50 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.27347 0.00035 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.27347 0.00035 1.27347 0.00000 12:24:50 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.27347 0.00035 SL = 1.2734736 +- 0.0003492 Tm^2/m^n 12:24:50 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2734736 +- 0.0003492 Tm^2/m^n 12:24:52 Magnet Current, Imag = 399.9280 A Vtrans = 3.999280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:24:53 Magnet Current, Imag = 399.9160 A Vtrans = 3.999160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:24:55 Magnet Current, Imag = 399.9060 A Vtrans = 3.999060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:24:56 Magnet Current, Imag = 399.9170 A Vtrans = 3.999170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:24:56 Magnet Current Measurement: Imag = 399.9167 +- 0.0078 A 12:24:57 Magnet current ramping to 450.0000 A... 12:25:19 Magnet Current, Imag = 449.9800 A Vtrans = 4.499800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:21 Magnet Current, Imag = 449.9780 A Vtrans = 4.499780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:22 Magnet Current, Imag = 450.0010 A Vtrans = 4.500010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:24 Magnet Current, Imag = 450.0050 A Vtrans = 4.500050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:24 Magnet Current Measurement: Imag = 449.9910 +- 0.0121 A 12:25:24 Magnetic Field Measurement Measuring the magnet strength... 12:25:24 Integrated Voltage Measurement... 12:25:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014327349 Vs 12:25:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014323148 Vs 12:25:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014324882 Vs 12:26:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014328240 Vs 12:26:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014322384 Vs 12:26:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014318841 Vs 12:26:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014327235 Vs 12:26:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014328153 Vs 12:26:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014325029 +- 0.000002693 Vs 12:26:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014325029 +- 0.000002693 Vs BL = 1.43250289 +- 0.00026927 Tm 12:26:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43250 0.00027 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.43250 0.00027 1.43250 0.00000 12:26:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43250 0.00027 SL = 1.4325029 +- 0.0002693 Tm^2/m^n 12:26:54 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4325029 +- 0.0002693 Tm^2/m^n 12:26:55 Magnet Current, Imag = 449.9990 A Vtrans = 4.499990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:26:57 Magnet Current, Imag = 449.9930 A Vtrans = 4.499930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:26:58 Magnet Current, Imag = 449.9960 A Vtrans = 4.499960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:00 Magnet Current, Imag = 449.9890 A Vtrans = 4.499890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:00 Magnet Current Measurement: Imag = 449.9942 +- 0.0037 A 12:27:00 Magnet current ramping to 500.0000 A... 12:27:23 Magnet Current, Imag = 500.0700 A Vtrans = 5.000700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:24 Magnet Current, Imag = 500.0730 A Vtrans = 5.000730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:26 Magnet Current, Imag = 500.0540 A Vtrans = 5.000540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:27 Magnet Current, Imag = 500.0640 A Vtrans = 5.000640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:28 Magnet Current Measurement: Imag = 500.0652 +- 0.0073 A 12:27:28 Magnetic Field Measurement Measuring the magnet strength... 12:27:28 Integrated Voltage Measurement... 12:27:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015912639 Vs 12:27:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015908689 Vs 12:28:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015913146 Vs 12:28:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015906361 Vs 12:28:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015914793 Vs 12:28:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015907999 Vs 12:28:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015919369 Vs 12:28:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015914441 Vs 12:28:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015912179 +- 0.000002790 Vs 12:28:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015912179 +- 0.000002790 Vs BL = 1.59121795 +- 0.00027896 Tm 12:28:58 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.59122 0.00028 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.59122 0.00028 1.59122 0.00000 12:28:58 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.59122 0.00028 SL = 1.5912179 +- 0.0002790 Tm^2/m^n 12:28:58 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5912179 +- 0.0002790 Tm^2/m^n 12:28:59 Magnet Current, Imag = 500.0680 A Vtrans = 5.000680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:01 Magnet Current, Imag = 500.0600 A Vtrans = 5.000600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:03 Magnet Current, Imag = 500.0660 A Vtrans = 5.000660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:04 Magnet Current, Imag = 500.0720 A Vtrans = 5.000720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:04 Magnet Current Measurement: Imag = 500.0665 +- 0.0043 A 12:29:04 Magnet current ramping to 525.0000 A... 12:29:22 Magnet Current, Imag = 525.0860 A Vtrans = 5.250860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:24 Magnet Current, Imag = 525.0910 A Vtrans = 5.250910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:25 Magnet Current, Imag = 525.0900 A Vtrans = 5.250900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:27 Magnet Current, Imag = 525.0940 A Vtrans = 5.250940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:27 Magnet Current Measurement: Imag = 525.0902 +- 0.0029 A 12:29:27 Magnetic Field Measurement Measuring the magnet strength... 12:29:27 Integrated Voltage Measurement... 12:29:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016700081 Vs 12:29:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016709807 Vs 12:30:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016717878 Vs 12:30:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016700230 Vs 12:30:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016705482 Vs 12:30:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016704484 Vs 12:30:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016699782 Vs 12:30:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016694703 Vs 12:30:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016704056 +- 0.000004273 Vs 12:30:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016704056 +- 0.000004273 Vs BL = 1.67040558 +- 0.00042734 Tm 12:30:57 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.67041 0.00043 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.67041 0.00043 1.67041 0.00000 12:30:57 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.67041 0.00043 SL = 1.6704056 +- 0.0004273 Tm^2/m^n 12:30:57 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6704056 +- 0.0004273 Tm^2/m^n 12:30:58 Magnet Current, Imag = 525.1100 A Vtrans = 5.251100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:00 Magnet Current, Imag = 525.0960 A Vtrans = 5.250960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:01 Magnet Current, Imag = 525.0990 A Vtrans = 5.250990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:03 Magnet Current, Imag = 525.0890 A Vtrans = 5.250890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:03 Magnet Current Measurement: Imag = 525.0985 +- 0.0076 A 12:31:03 Magnet current ramping to 550.0000 A... 12:31:19 Magnet Current, Imag = 549.9990 A Vtrans = 5.499990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:20 Magnet Current, Imag = 550.0580 A Vtrans = 5.500580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:22 Magnet Current, Imag = 550.0700 A Vtrans = 5.500700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:23 Magnet Current, Imag = 550.0860 A Vtrans = 5.500860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:23 Magnet Current Measurement: Imag = 550.0533 +- 0.0329 A 12:31:23 Magnetic Field Measurement Measuring the magnet strength... 12:31:23 Integrated Voltage Measurement... 12:31:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017473597 Vs 12:31:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017482831 Vs 12:31:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017489505 Vs 12:32:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017490741 Vs 12:32:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017498290 Vs 12:32:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017496333 Vs 12:32:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017490591 Vs 12:32:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017496674 Vs 12:32:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017489820 +- 0.000007167 Vs 12:32:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017489820 +- 0.000007167 Vs BL = 1.74898202 +- 0.00071667 Tm 12:32:53 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.74898 0.00072 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.74898 0.00072 1.74898 0.00000 12:32:53 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.74898 0.00072 SL = 1.7489820 +- 0.0007167 Tm^2/m^n 12:32:53 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7489820 +- 0.0007167 Tm^2/m^n 12:32:54 Magnet Current, Imag = 550.0850 A Vtrans = 5.500850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:32:56 Magnet Current, Imag = 550.0910 A Vtrans = 5.500910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:32:57 Magnet Current, Imag = 550.0950 A Vtrans = 5.500950 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:32:59 Magnet Current, Imag = 550.1020 A Vtrans = 5.501020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:32:59 Magnet Current Measurement: Imag = 550.0932 +- 0.0062 A 12:32:59 Magnet current ramping to 575.0000 A... 12:33:14 Magnet Current, Imag = 575.0760 A Vtrans = 5.750760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:16 Magnet Current, Imag = 575.1080 A Vtrans = 5.751080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:17 Magnet Current, Imag = 575.1150 A Vtrans = 5.751150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:19 Magnet Current, Imag = 575.1240 A Vtrans = 5.751240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:19 Magnet Current Measurement: Imag = 575.1057 +- 0.0181 A 12:33:19 Magnetic Field Measurement Measuring the magnet strength... 12:33:19 Integrated Voltage Measurement... 12:33:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018261480 Vs 12:33:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018258860 Vs 12:33:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018260761 Vs 12:34:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018259405 Vs 12:34:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018262409 Vs 12:34:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018269961 Vs 12:34:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018259435 Vs 12:34:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018254249 Vs 12:34:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018260820 +- 0.000003376 Vs 12:34:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.018260820 +- 0.000003376 Vs BL = 1.82608201 +- 0.00033756 Tm 12:34:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.82608 0.00034 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.82608 0.00034 1.82608 0.00000 12:34:51 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.82608 0.00034 SL = 1.8260820 +- 0.0003376 Tm^2/m^n 12:34:51 Magnet Strength Measurement Harmonic Number = 1 SL = 1.8260820 +- 0.0003376 Tm^2/m^n 12:34:52 Magnet Current, Imag = 575.1170 A Vtrans = 5.751170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:34:55 Magnet Current, Imag = 575.1100 A Vtrans = 5.751100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:34:56 Magnet Current, Imag = 575.0960 A Vtrans = 5.750960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:34:58 Magnet Current, Imag = 575.1160 A Vtrans = 5.751160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:34:58 Magnet Current Measurement: Imag = 575.1097 +- 0.0084 A 12:34:58 Magnet current ramping to 600.0000 A... 12:35:13 Magnet Current, Imag = 600.0920 A Vtrans = 6.000920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:15 Magnet Current, Imag = 600.1230 A Vtrans = 6.001230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:16 Magnet Current, Imag = 600.1550 A Vtrans = 6.001550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:18 Magnet Current, Imag = 600.1340 A Vtrans = 6.001340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:18 Magnet Current Measurement: Imag = 600.1260 +- 0.0227 A 12:35:18 Magnetic Field Measurement Measuring the magnet strength... 12:35:18 Integrated Voltage Measurement... 12:35:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019022037 Vs 12:35:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019040481 Vs 12:35:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019008642 Vs 12:36:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019022443 Vs 12:36:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019036568 Vs 12:36:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019022631 Vs 12:36:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019026729 Vs 12:36:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019031350 Vs 12:36:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019026360 +- 0.000006299 Vs 12:36:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019026360 +- 0.000006299 Vs BL = 1.90263602 +- 0.00062986 Tm 12:36:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.90264 0.00063 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.90264 0.00063 1.90264 0.00000 12:36:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.90264 0.00063 SL = 1.9026360 +- 0.0006299 Tm^2/m^n 12:36:47 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9026360 +- 0.0006299 Tm^2/m^n 12:36:49 Magnet Current, Imag = 600.1330 A Vtrans = 6.001330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:36:50 Magnet Current, Imag = 600.1640 A Vtrans = 6.001640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:36:52 Magnet Current, Imag = 600.1680 A Vtrans = 6.001680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:36:54 Magnet Current, Imag = 600.1620 A Vtrans = 6.001620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:36:54 Magnet Current Measurement: Imag = 600.1567 +- 0.0139 A 12:36:54 Magnet current ramping to 625.0000 A... 12:37:10 Magnet Current, Imag = 625.2060 A Vtrans = 6.252060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:37:12 Magnet Current, Imag = 625.1910 A Vtrans = 6.251910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:37:14 Magnet Current, Imag = 625.1910 A Vtrans = 6.251910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:37:15 Magnet Current, Imag = 625.1950 A Vtrans = 6.251950 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:37:15 Magnet Current Measurement: Imag = 625.1957 +- 0.0061 A 12:37:15 Magnetic Field Measurement Measuring the magnet strength... 12:37:15 Integrated Voltage Measurement... 12:37:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019771137 Vs 12:37:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019757525 Vs 12:37:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019765048 Vs 12:38:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019772141 Vs 12:38:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019767905 Vs 12:38:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019769436 Vs 12:38:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019780135 Vs 12:38:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019800305 Vs 12:38:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019772954 +- 0.000010122 Vs 12:38:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019772954 +- 0.000010122 Vs BL = 1.97729541 +- 0.00101220 Tm 12:38:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.97730 0.00101 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.97730 0.00101 1.97730 0.00000 12:38:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.97730 0.00101 SL = 1.9772954 +- 0.0010122 Tm^2/m^n 12:38:49 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9772954 +- 0.0010122 Tm^2/m^n 12:38:50 Magnet Current, Imag = 625.1940 A Vtrans = 6.251940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:38:52 Magnet Current, Imag = 625.2030 A Vtrans = 6.252030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:38:53 Magnet Current, Imag = 625.1730 A Vtrans = 6.251730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:38:55 Magnet Current, Imag = 625.1810 A Vtrans = 6.251810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:38:55 Magnet Current Measurement: Imag = 625.1877 +- 0.0116 A 12:38:55 Magnet current ramping to 650.0000 A... 12:39:11 Magnet Current, Imag = 650.2280 A Vtrans = 6.502280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:39:13 Magnet Current, Imag = 650.2540 A Vtrans = 6.502540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:39:14 Magnet Current, Imag = 650.2470 A Vtrans = 6.502470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:39:16 Magnet Current, Imag = 650.2200 A Vtrans = 6.502200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:39:16 Magnet Current Measurement: Imag = 650.2373 +- 0.0138 A 12:39:16 Magnetic Field Measurement Measuring the magnet strength... 12:39:16 Integrated Voltage Measurement... 12:39:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020483071 Vs 12:39:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020470551 Vs 12:39:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020482977 Vs 12:40:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020478252 Vs 12:40:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020480370 Vs 12:40:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020494889 Vs 12:40:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020490237 Vs 12:40:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020483163 Vs 12:40:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020482939 +- 0.000004447 Vs 12:40:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020482939 +- 0.000004447 Vs BL = 2.04829387 +- 0.00044471 Tm 12:40:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.04829 0.00044 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.04829 0.00044 2.04829 0.00000 12:40:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.04829 0.00044 SL = 2.0482939 +- 0.0004447 Tm^2/m^n 12:40:49 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0482939 +- 0.0004447 Tm^2/m^n 12:40:50 Magnet Current, Imag = 650.2230 A Vtrans = 6.502230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:40:52 Magnet Current, Imag = 650.2240 A Vtrans = 6.502240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:40:53 Magnet Current, Imag = 650.2420 A Vtrans = 6.502420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:40:55 Magnet Current, Imag = 650.2190 A Vtrans = 6.502190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:40:55 Magnet Current Measurement: Imag = 650.2270 +- 0.0089 A 12:40:55 Magnet current ramping to 675.0000 A... 12:41:10 Magnet Current, Imag = 675.2700 A Vtrans = 6.752700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:41:12 Magnet Current, Imag = 675.2280 A Vtrans = 6.752280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:41:13 Magnet Current, Imag = 675.2590 A Vtrans = 6.752590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:41:15 Magnet Current, Imag = 675.2580 A Vtrans = 6.752580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:41:15 Magnet Current Measurement: Imag = 675.2537 +- 0.0156 A 12:41:15 Magnetic Field Measurement Measuring the magnet strength... 12:41:15 Integrated Voltage Measurement... 12:41:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021145032 Vs 12:41:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021145669 Vs 12:41:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021170653 Vs 12:41:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021156103 Vs 12:42:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021151310 Vs 12:42:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021149703 Vs 12:42:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021149499 Vs 12:42:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021155105 Vs 12:42:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021152884 +- 0.000006574 Vs 12:42:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021152884 +- 0.000006574 Vs BL = 2.11528843 +- 0.00065741 Tm 12:42:44 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.11529 0.00066 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.11529 0.00066 2.11529 0.00000 12:42:44 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.11529 0.00066 SL = 2.1152884 +- 0.0006574 Tm^2/m^n 12:42:44 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1152884 +- 0.0006574 Tm^2/m^n 12:42:46 Magnet Current, Imag = 675.2550 A Vtrans = 6.752550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:42:47 Magnet Current, Imag = 675.2660 A Vtrans = 6.752660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:42:49 Magnet Current, Imag = 675.3190 A Vtrans = 6.753190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:42:50 Magnet Current, Imag = 675.2640 A Vtrans = 6.752640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:42:50 Magnet Current Measurement: Imag = 675.2760 +- 0.0252 A 12:42:51 Magnet current ramping to 700.0000 A... 12:43:06 Magnet Current, Imag = 700.3790 A Vtrans = 7.003790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:43:08 Magnet Current, Imag = 700.3030 A Vtrans = 7.003030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:43:09 Magnet Current, Imag = 700.2840 A Vtrans = 7.002840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:43:11 Magnet Current, Imag = 700.2580 A Vtrans = 7.002580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:43:11 Magnet Current Measurement: Imag = 700.3060 +- 0.0451 A 12:43:11 Magnetic Field Measurement Measuring the magnet strength... 12:43:11 Integrated Voltage Measurement... 12:43:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021782166 Vs 12:43:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021781797 Vs 12:43:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021779284 Vs 12:43:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021781485 Vs 12:44:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021788719 Vs 12:44:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021781792 Vs 12:44:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021781845 Vs 12:44:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021782202 Vs 12:44:38 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021782411 +- 0.000001770 Vs 12:44:38 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021782411 +- 0.000001770 Vs BL = 2.17824114 +- 0.00017701 Tm 12:44:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.17824 0.00018 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.17824 0.00018 2.17824 0.00000 12:44:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.17824 0.00018 SL = 2.1782411 +- 0.0001770 Tm^2/m^n 12:44:41 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1782411 +- 0.0001770 Tm^2/m^n 12:44:42 Magnet Current, Imag = 700.2730 A Vtrans = 7.002730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:44:44 Magnet Current, Imag = 700.2880 A Vtrans = 7.002880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:44:46 Magnet Current, Imag = 700.2530 A Vtrans = 7.002530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:44:48 Magnet Current, Imag = 700.2700 A Vtrans = 7.002700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:44:48 Magnet Current Measurement: Imag = 700.2710 +- 0.0124 A 12:44:48 Magnet current ramping to 650.0000 A... 12:45:11 Magnet Current, Imag = 650.1990 A Vtrans = 6.501990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:45:13 Magnet Current, Imag = 650.2200 A Vtrans = 6.502200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:45:15 Magnet Current, Imag = 650.2270 A Vtrans = 6.502270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:45:16 Magnet Current, Imag = 650.2230 A Vtrans = 6.502230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:45:16 Magnet Current Measurement: Imag = 650.2172 +- 0.0108 A 12:45:16 Magnetic Field Measurement Measuring the magnet strength... 12:45:17 Integrated Voltage Measurement... 12:45:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020565772 Vs 12:45:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020549263 Vs 12:45:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020563835 Vs 12:46:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020551542 Vs 12:46:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020553878 Vs 12:46:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020567863 Vs 12:46:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020560744 Vs 12:46:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020559627 Vs 12:46:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020559066 +- 0.000001484 Vs 12:46:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020559066 +- 0.000001484 Vs BL = 2.05590656 +- 0.00014836 Tm 12:46:46 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.05591 0.00015 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.05591 0.00015 2.05591 0.00000 12:46:46 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.05591 0.00015 SL = 2.0559066 +- 0.0001484 Tm^2/m^n 12:46:46 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0559066 +- 0.0001484 Tm^2/m^n 12:46:48 Magnet Current, Imag = 650.2280 A Vtrans = 6.502280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:46:50 Magnet Current, Imag = 650.2050 A Vtrans = 6.502050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:46:51 Magnet Current, Imag = 650.1940 A Vtrans = 6.501940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:46:53 Magnet Current, Imag = 650.2180 A Vtrans = 6.502180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:46:53 Magnet Current Measurement: Imag = 650.2112 +- 0.0129 A 12:46:53 Magnet current ramping to 600.0000 A... 12:47:15 Magnet Current, Imag = 600.1280 A Vtrans = 6.001280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:47:17 Magnet Current, Imag = 600.1110 A Vtrans = 6.001110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:47:18 Magnet Current, Imag = 600.1030 A Vtrans = 6.001030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:47:20 Magnet Current, Imag = 600.1270 A Vtrans = 6.001270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:47:20 Magnet Current Measurement: Imag = 600.1173 +- 0.0106 A 12:47:20 Magnetic Field Measurement Measuring the magnet strength... 12:47:20 Integrated Voltage Measurement... 12:47:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019138857 Vs 12:47:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019098977 Vs 12:47:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019104748 Vs 12:48:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019067596 Vs 12:48:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019111850 Vs 12:48:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019101713 Vs 12:48:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019105784 Vs 12:48:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019092298 Vs 12:48:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019102728 +- 0.000011898 Vs 12:48:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019102728 +- 0.000011898 Vs BL = 1.91027279 +- 0.00118976 Tm 12:48:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.91027 0.00119 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.91027 0.00119 1.91027 0.00000 12:48:51 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.91027 0.00119 SL = 1.9102728 +- 0.0011898 Tm^2/m^n 12:48:51 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9102728 +- 0.0011898 Tm^2/m^n 12:48:52 Magnet Current, Imag = 600.1390 A Vtrans = 6.001390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:48:54 Magnet Current, Imag = 600.1590 A Vtrans = 6.001590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:48:55 Magnet Current, Imag = 600.1440 A Vtrans = 6.001440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:48:57 Magnet Current, Imag = 600.1370 A Vtrans = 6.001370 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:48:57 Magnet Current Measurement: Imag = 600.1447 +- 0.0086 A 12:48:57 Magnet current ramping to 550.0000 A... 12:49:20 Magnet Current, Imag = 550.0830 A Vtrans = 5.500830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:49:22 Magnet Current, Imag = 550.1030 A Vtrans = 5.501030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:49:23 Magnet Current, Imag = 550.1500 A Vtrans = 5.501500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:49:25 Magnet Current, Imag = 550.1280 A Vtrans = 5.501280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:49:25 Magnet Current Measurement: Imag = 550.1160 +- 0.0253 A 12:49:25 Magnetic Field Measurement Measuring the magnet strength... 12:49:25 Integrated Voltage Measurement... 12:49:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017555977 Vs 12:49:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017559344 Vs 12:49:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017552601 Vs 12:50:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017548841 Vs 12:50:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017549719 Vs 12:50:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017557641 Vs 12:50:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017558017 Vs 12:50:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017533059 Vs 12:50:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017551900 +- 0.000004422 Vs 12:50:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017551900 +- 0.000004422 Vs BL = 1.75519000 +- 0.00044220 Tm 12:50:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.75519 0.00044 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.75519 0.00044 1.75519 0.00000 12:50:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.75519 0.00044 SL = 1.7551900 +- 0.0004422 Tm^2/m^n 12:50:55 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7551900 +- 0.0004422 Tm^2/m^n 12:50:56 Magnet Current, Imag = 550.0880 A Vtrans = 5.500880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:50:58 Magnet Current, Imag = 550.0850 A Vtrans = 5.500850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:50:59 Magnet Current, Imag = 550.0900 A Vtrans = 5.500900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:51:01 Magnet Current, Imag = 550.0710 A Vtrans = 5.500710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:51:01 Magnet Current Measurement: Imag = 550.0835 +- 0.0074 A 12:51:01 Magnet current ramping to 500.0000 A... 12:51:25 Magnet Current, Imag = 500.0740 A Vtrans = 5.000740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:51:27 Magnet Current, Imag = 500.0740 A Vtrans = 5.000740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:51:28 Magnet Current, Imag = 500.0780 A Vtrans = 5.000780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:51:30 Magnet Current, Imag = 500.0700 A Vtrans = 5.000700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:51:30 Magnet Current Measurement: Imag = 500.0740 +- 0.0028 A 12:51:30 Magnetic Field Measurement Measuring the magnet strength... 12:51:30 Integrated Voltage Measurement... 12:51:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015973715 Vs 12:51:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015979411 Vs 12:52:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015989461 Vs 12:52:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015967463 Vs 12:52:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015976703 Vs 12:52:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015963300 Vs 12:52:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015986186 Vs 12:53:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015968681 Vs 12:53:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015975615 +- 0.000003310 Vs 12:53:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015975615 +- 0.000003310 Vs BL = 1.59756151 +- 0.00033099 Tm 12:53:03 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.59756 0.00033 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.59756 0.00033 1.59756 0.00000 12:53:03 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.59756 0.00033 SL = 1.5975615 +- 0.0003310 Tm^2/m^n 12:53:03 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5975615 +- 0.0003310 Tm^2/m^n 12:53:05 Magnet Current, Imag = 500.0610 A Vtrans = 5.000610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:53:06 Magnet Current, Imag = 500.0560 A Vtrans = 5.000560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:53:08 Magnet Current, Imag = 500.0710 A Vtrans = 5.000710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:53:09 Magnet Current, Imag = 500.0700 A Vtrans = 5.000700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:53:09 Magnet Current Measurement: Imag = 500.0645 +- 0.0063 A 12:53:09 Magnet current ramping to 450.0000 A... 12:53:33 Magnet Current, Imag = 449.9940 A Vtrans = 4.499940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:53:35 Magnet Current, Imag = 449.9870 A Vtrans = 4.499870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:53:36 Magnet Current, Imag = 449.9930 A Vtrans = 4.499930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:53:38 Magnet Current, Imag = 449.9930 A Vtrans = 4.499930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:53:38 Magnet Current Measurement: Imag = 449.9917 +- 0.0028 A 12:53:38 Magnetic Field Measurement Measuring the magnet strength... 12:53:38 Integrated Voltage Measurement... 12:53:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014397725 Vs 12:54:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014377988 Vs 12:54:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014393395 Vs 12:54:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014370459 Vs 12:54:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014382165 Vs 12:54:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014386884 Vs 12:54:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014391279 Vs 12:55:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014381141 Vs 12:55:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014385129 +- 0.000002192 Vs 12:55:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014385129 +- 0.000002192 Vs BL = 1.43851295 +- 0.00021924 Tm 12:55:08 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43851 0.00022 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.43851 0.00022 1.43851 0.00000 12:55:08 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43851 0.00022 SL = 1.4385130 +- 0.0002192 Tm^2/m^n 12:55:08 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4385130 +- 0.0002192 Tm^2/m^n 12:55:10 Magnet Current, Imag = 450.0080 A Vtrans = 4.500080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:55:11 Magnet Current, Imag = 449.9800 A Vtrans = 4.499800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:55:13 Magnet Current, Imag = 450.0150 A Vtrans = 4.500150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:55:14 Magnet Current, Imag = 450.0020 A Vtrans = 4.500020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:55:14 Magnet Current Measurement: Imag = 450.0012 +- 0.0131 A 12:55:14 Magnet current ramping to 400.0000 A... 12:55:37 Magnet Current, Imag = 399.9540 A Vtrans = 3.999540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:55:39 Magnet Current, Imag = 399.9660 A Vtrans = 3.999660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:55:40 Magnet Current, Imag = 399.9520 A Vtrans = 3.999520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:55:42 Magnet Current, Imag = 399.9490 A Vtrans = 3.999490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:55:42 Magnet Current Measurement: Imag = 399.9552 +- 0.0065 A 12:55:42 Magnetic Field Measurement Measuring the magnet strength... 12:55:42 Integrated Voltage Measurement... 12:55:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012784164 Vs 12:56:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012791191 Vs 12:56:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012789801 Vs 12:56:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012783211 Vs 12:56:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012789514 Vs 12:56:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012795133 Vs 12:56:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012794738 Vs 12:57:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012791892 Vs 12:57:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012789956 +- 0.000002915 Vs 12:57:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012789956 +- 0.000002915 Vs BL = 1.27899555 +- 0.00029146 Tm 12:57:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.27900 0.00029 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.27900 0.00029 1.27900 0.00000 12:57:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.27900 0.00029 SL = 1.2789956 +- 0.0002915 Tm^2/m^n 12:57:13 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2789956 +- 0.0002915 Tm^2/m^n 12:57:14 Magnet Current, Imag = 399.9530 A Vtrans = 3.999530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:57:16 Magnet Current, Imag = 399.9350 A Vtrans = 3.999350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:57:18 Magnet Current, Imag = 399.9340 A Vtrans = 3.999340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:57:19 Magnet Current, Imag = 399.9300 A Vtrans = 3.999300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:57:19 Magnet Current Measurement: Imag = 399.9380 +- 0.0089 A 12:57:50 Magnet current ramping to 0.0000 A...