SLAC Magnetic Measurements Date: 08-02-2001 Time: 15:09:32 Project: spear3 Magnet Type: gdipole Magnet Name: 145d-016 Serial Number: Run Number: 5 Measurement Device: stretched wire Operator: jy Comment: Bl vs. I, mains Standardization: 1 cycles from 0.0 A to 770.0 A to 0.0 A Test Currents (A): 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 500.0 525.0 550.0 575.0 600.0 625.0 650.0 675.0 700.0 650.0 600.0 550.0 500.0 450.0 400.0 15:09:42 Initial Zero Current Measurement, Imag_zero = 0.0000 A 15:09:42 Magnet current ramping to 15.0000 A... 15:10:13 Magnet current ramping to 770.0000 A... 15:14:28 Magnet current ramping to 0.0000 A... 15:19:16 Magnet current ramping to 50.0000 A... 15:19:39 Magnet Current, Imag = 62.3649 A Vtrans = 0.623649 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:19:41 Magnet Current, Imag = 45.9697 A Vtrans = 0.459697 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:19:42 Magnet Current, Imag = 47.6323 A Vtrans = 0.476323 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:19:44 Magnet Current, Imag = 51.6644 A Vtrans = 0.516644 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:19:44 Magnet Current Measurement: Imag = 51.9078 +- 6.3826 A 15:19:44 Magnetic Field Measurement Measuring the magnet strength... 15:19:44 Integrated Voltage Measurement... 15:19:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001551863 Vs 15:20:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001761706 Vs 15:20:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001439271 Vs 15:20:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001752219 Vs 15:20:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001446414 Vs 15:20:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001764999 Vs 15:21:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001440840 Vs 15:21:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001767601 Vs 15:21:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001615614 +- 0.000024072 Vs 15:21:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001615614 +- 0.000024072 Vs BL = 0.16156142 +- 0.00240716 Tm 15:21:16 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.16156 0.00241 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.16156 0.00241 0.16156 0.00000 15:21:16 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.16156 0.00241 SL = 0.1615614 +- 0.0024072 Tm^2/m^n 15:21:16 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1615614 +- 0.0024072 Tm^2/m^n 15:21:18 Magnet Current, Imag = 49.8294 A Vtrans = 0.498294 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:21:19 Magnet Current, Imag = 49.8175 A Vtrans = 0.498175 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:21:20 Magnet Current, Imag = 49.8297 A Vtrans = 0.498297 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:21:22 Magnet Current, Imag = 49.8461 A Vtrans = 0.498461 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:21:22 Magnet Current Measurement: Imag = 49.8307 +- 0.0102 A 15:21:22 Magnet current ramping to 100.0000 A... 15:21:45 Magnet Current, Imag = 99.8756 A Vtrans = 0.998756 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:21:46 Magnet Current, Imag = 99.8891 A Vtrans = 0.998891 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:21:48 Magnet Current, Imag = 99.8800 A Vtrans = 0.998800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:21:49 Magnet Current, Imag = 99.8840 A Vtrans = 0.998840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:21:49 Magnet Current Measurement: Imag = 99.8822 +- 0.0050 A 15:21:50 Magnetic Field Measurement Measuring the magnet strength... 15:21:50 Integrated Voltage Measurement... 15:22:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003025459 Vs 15:22:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003326161 Vs 15:22:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003025875 Vs 15:22:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003343545 Vs 15:22:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003008041 Vs 15:22:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003329919 Vs 15:23:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003020877 Vs 15:23:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003325553 Vs 15:23:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003175679 +- 0.000005756 Vs 15:23:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.003175679 +- 0.000005756 Vs BL = 0.31756787 +- 0.00057559 Tm 15:23:21 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.31757 0.00058 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.31757 0.00058 0.31757 0.00000 15:23:21 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.31757 0.00058 SL = 0.3175679 +- 0.0005756 Tm^2/m^n 15:23:21 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3175679 +- 0.0005756 Tm^2/m^n 15:23:23 Magnet Current, Imag = 99.8832 A Vtrans = 0.998832 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:24 Magnet Current, Imag = 99.8931 A Vtrans = 0.998931 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:26 Magnet Current, Imag = 99.8886 A Vtrans = 0.998886 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:27 Magnet Current, Imag = 99.8772 A Vtrans = 0.998772 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:28 Magnet Current Measurement: Imag = 99.8855 +- 0.0059 A 15:23:28 Magnet current ramping to 150.0000 A... 15:23:50 Magnet Current, Imag = 149.8691 A Vtrans = 1.498691 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:52 Magnet Current, Imag = 149.8630 A Vtrans = 1.498630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:53 Magnet Current, Imag = 149.8834 A Vtrans = 1.498834 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:55 Magnet Current, Imag = 149.9116 A Vtrans = 1.499116 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:55 Magnet Current Measurement: Imag = 149.8818 +- 0.0187 A 15:23:55 Magnetic Field Measurement Measuring the magnet strength... 15:23:55 Integrated Voltage Measurement... 15:24:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004608441 Vs 15:24:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004914375 Vs 15:24:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004596255 Vs 15:24:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004922652 Vs 15:24:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004607616 Vs 15:25:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004931216 Vs 15:25:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004612927 Vs 15:25:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004935105 Vs 15:25:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004766073 +- 0.000005913 Vs 15:25:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004766073 +- 0.000005913 Vs BL = 0.47660733 +- 0.00059129 Tm 15:25:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.47661 0.00059 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.47661 0.00059 0.47661 0.00000 15:25:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.47661 0.00059 SL = 0.4766073 +- 0.0005913 Tm^2/m^n 15:25:27 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4766073 +- 0.0005913 Tm^2/m^n 15:25:28 Magnet Current, Imag = 149.8806 A Vtrans = 1.498806 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:25:30 Magnet Current, Imag = 149.8898 A Vtrans = 1.498898 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:25:31 Magnet Current, Imag = 149.8940 A Vtrans = 1.498940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:25:33 Magnet Current, Imag = 149.9304 A Vtrans = 1.499304 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:25:33 Magnet Current Measurement: Imag = 149.8987 +- 0.0189 A 15:25:33 Magnet current ramping to 200.0000 A... 15:25:56 Magnet Current, Imag = 199.8839 A Vtrans = 1.998839 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:25:57 Magnet Current, Imag = 199.9073 A Vtrans = 1.999073 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:25:59 Magnet Current, Imag = 199.9061 A Vtrans = 1.999061 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:26:00 Magnet Current, Imag = 199.9052 A Vtrans = 1.999052 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:26:01 Magnet Current Measurement: Imag = 199.9006 +- 0.0097 A 15:26:01 Magnetic Field Measurement Measuring the magnet strength... 15:26:01 Integrated Voltage Measurement... 15:26:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006198664 Vs 15:26:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006523193 Vs 15:26:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006193549 Vs 15:26:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006516025 Vs 15:26:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006197212 Vs 15:27:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006513458 Vs 15:27:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006198640 Vs 15:27:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006524218 Vs 15:27:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006358120 +- 0.000003070 Vs 15:27:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006358120 +- 0.000003070 Vs BL = 0.63581198 +- 0.00030702 Tm 15:27:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.63581 0.00031 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.63581 0.00031 0.63581 0.00000 15:27:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.63581 0.00031 SL = 0.6358120 +- 0.0003070 Tm^2/m^n 15:27:32 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6358120 +- 0.0003070 Tm^2/m^n 15:27:34 Magnet Current, Imag = 199.9107 A Vtrans = 1.999107 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:27:35 Magnet Current, Imag = 199.8866 A Vtrans = 1.998866 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:27:37 Magnet Current, Imag = 199.8894 A Vtrans = 1.998894 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:27:38 Magnet Current, Imag = 199.9072 A Vtrans = 1.999072 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:27:38 Magnet Current Measurement: Imag = 199.8985 +- 0.0106 A 15:27:38 Magnet current ramping to 250.0000 A... 15:28:01 Magnet Current, Imag = 249.9354 A Vtrans = 2.499354 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:03 Magnet Current, Imag = 249.9541 A Vtrans = 2.499541 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:04 Magnet Current, Imag = 249.9545 A Vtrans = 2.499545 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:06 Magnet Current, Imag = 249.9569 A Vtrans = 2.499569 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:06 Magnet Current Measurement: Imag = 249.9502 +- 0.0086 A 15:28:06 Magnetic Field Measurement Measuring the magnet strength... 15:28:06 Integrated Voltage Measurement... 15:28:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007791027 Vs 15:28:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008108164 Vs 15:28:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007789131 Vs 15:28:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008120145 Vs 15:29:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007792559 Vs 15:29:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008116347 Vs 15:29:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007788301 Vs 15:29:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008109349 Vs 15:29:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007951878 +- 0.000002682 Vs 15:29:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.007951878 +- 0.000002682 Vs BL = 0.79518776 +- 0.00026823 Tm 15:29:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.79519 0.00027 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.79519 0.00027 0.79519 0.00000 15:29:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.79519 0.00027 SL = 0.7951878 +- 0.0002682 Tm^2/m^n 15:29:38 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7951878 +- 0.0002682 Tm^2/m^n 15:29:39 Magnet Current, Imag = 249.9355 A Vtrans = 2.499355 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:29:41 Magnet Current, Imag = 249.9384 A Vtrans = 2.499384 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:29:42 Magnet Current, Imag = 249.9409 A Vtrans = 2.499409 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:29:44 Magnet Current, Imag = 249.9437 A Vtrans = 2.499437 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:29:44 Magnet Current Measurement: Imag = 249.9396 +- 0.0030 A 15:29:44 Magnet current ramping to 300.0000 A... 15:30:07 Magnet Current, Imag = 299.9754 A Vtrans = 2.999754 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:08 Magnet Current, Imag = 299.9798 A Vtrans = 2.999798 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:10 Magnet Current, Imag = 299.9804 A Vtrans = 2.999804 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:11 Magnet Current, Imag = 299.9595 A Vtrans = 2.999595 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:11 Magnet Current Measurement: Imag = 299.9738 +- 0.0085 A 15:30:12 Magnetic Field Measurement Measuring the magnet strength... 15:30:12 Integrated Voltage Measurement... 15:30:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009361953 Vs 15:30:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009707039 Vs 15:30:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009378461 Vs 15:30:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009692448 Vs 15:31:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009388000 Vs 15:31:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009699320 Vs 15:31:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009374873 Vs 15:31:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009706197 Vs 15:31:40 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009538536 +- 0.000003744 Vs 15:31:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009538536 +- 0.000003744 Vs BL = 0.95385363 +- 0.00037439 Tm 15:31:43 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.95385 0.00037 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.95385 0.00037 0.95385 0.00000 15:31:43 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.95385 0.00037 SL = 0.9538536 +- 0.0003744 Tm^2/m^n 15:31:43 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9538536 +- 0.0003744 Tm^2/m^n 15:31:46 Magnet Current, Imag = 299.9448 A Vtrans = 2.999448 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:31:47 Magnet Current, Imag = 299.9705 A Vtrans = 2.999705 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:31:49 Magnet Current, Imag = 299.9624 A Vtrans = 2.999624 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:31:50 Magnet Current, Imag = 299.9706 A Vtrans = 2.999706 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:31:50 Magnet Current Measurement: Imag = 299.9621 +- 0.0105 A 15:31:50 Magnet current ramping to 350.0000 A... 15:32:14 Magnet Current, Imag = 350.0080 A Vtrans = 3.500080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:16 Magnet Current, Imag = 350.0110 A Vtrans = 3.500110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:18 Magnet Current, Imag = 350.0030 A Vtrans = 3.500030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:20 Magnet Current, Imag = 349.9910 A Vtrans = 3.499910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:20 Magnet Current Measurement: Imag = 350.0032 +- 0.0076 A 15:32:20 Magnetic Field Measurement Measuring the magnet strength... 15:32:20 Integrated Voltage Measurement... 15:32:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010974895 Vs 15:32:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011288912 Vs 15:32:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010986608 Vs 15:33:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011295555 Vs 15:33:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010971821 Vs 15:33:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011291032 Vs 15:33:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010982581 Vs 15:33:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011295134 Vs 15:33:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011135817 +- 0.000004229 Vs 15:33:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.011135817 +- 0.000004229 Vs BL = 1.11358172 +- 0.00042294 Tm 15:33:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.11358 0.00042 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.11358 0.00042 1.11358 0.00000 15:33:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.11358 0.00042 SL = 1.1135817 +- 0.0004229 Tm^2/m^n 15:33:52 Magnet Strength Measurement Harmonic Number = 1 SL = 1.1135817 +- 0.0004229 Tm^2/m^n 15:33:54 Magnet Current, Imag = 350.0170 A Vtrans = 3.500170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:33:56 Magnet Current, Imag = 349.9700 A Vtrans = 3.499700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:33:58 Magnet Current, Imag = 350.0410 A Vtrans = 3.500410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:00 Magnet Current, Imag = 350.0250 A Vtrans = 3.500250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:00 Magnet Current Measurement: Imag = 350.0132 +- 0.0264 A 15:34:00 Magnet current ramping to 400.0000 A... 15:34:24 Magnet Current, Imag = 400.0320 A Vtrans = 4.000320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:25 Magnet Current, Imag = 400.0430 A Vtrans = 4.000430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:27 Magnet Current, Imag = 400.0360 A Vtrans = 4.000360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:28 Magnet Current, Imag = 400.0420 A Vtrans = 4.000420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:28 Magnet Current Measurement: Imag = 400.0382 +- 0.0045 A 15:34:29 Magnetic Field Measurement Measuring the magnet strength... 15:34:29 Integrated Voltage Measurement... 15:34:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012564473 Vs 15:34:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012885099 Vs 15:35:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012567443 Vs 15:35:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012889962 Vs 15:35:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012556635 Vs 15:35:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012893227 Vs 15:35:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012559909 Vs 15:35:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012890013 Vs 15:35:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012725845 +- 0.000001651 Vs 15:35:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012725845 +- 0.000001651 Vs BL = 1.27258451 +- 0.00016510 Tm 15:36:01 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.27258 0.00017 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.27258 0.00017 1.27258 0.00000 15:36:01 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.27258 0.00017 SL = 1.2725845 +- 0.0001651 Tm^2/m^n 15:36:01 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2725845 +- 0.0001651 Tm^2/m^n 15:36:02 Magnet Current, Imag = 399.9950 A Vtrans = 3.999950 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:04 Magnet Current, Imag = 400.0180 A Vtrans = 4.000180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:06 Magnet Current, Imag = 400.0090 A Vtrans = 4.000090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:07 Magnet Current, Imag = 400.0110 A Vtrans = 4.000110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:07 Magnet Current Measurement: Imag = 400.0082 +- 0.0083 A 15:36:07 Magnet current ramping to 450.0000 A... 15:36:30 Magnet Current, Imag = 450.0500 A Vtrans = 4.500500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:32 Magnet Current, Imag = 450.0410 A Vtrans = 4.500410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:34 Magnet Current, Imag = 450.0500 A Vtrans = 4.500500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:35 Magnet Current, Imag = 450.0640 A Vtrans = 4.500640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:35 Magnet Current Measurement: Imag = 450.0512 +- 0.0082 A 15:36:35 Magnetic Field Measurement Measuring the magnet strength... 15:36:36 Integrated Voltage Measurement... 15:36:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014150036 Vs 15:36:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014475870 Vs 15:37:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014152164 Vs 15:37:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014502963 Vs 15:37:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014158935 Vs 15:37:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014470031 Vs 15:37:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014143103 Vs 15:38:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014484264 Vs 15:38:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014317171 +- 0.000006025 Vs 15:38:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014317171 +- 0.000006025 Vs BL = 1.43171706 +- 0.00060246 Tm 15:38:07 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43172 0.00060 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.43172 0.00060 1.43172 0.00000 15:38:07 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43172 0.00060 SL = 1.4317171 +- 0.0006025 Tm^2/m^n 15:38:07 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4317171 +- 0.0006025 Tm^2/m^n 15:38:09 Magnet Current, Imag = 450.0610 A Vtrans = 4.500610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:10 Magnet Current, Imag = 450.0470 A Vtrans = 4.500470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:12 Magnet Current, Imag = 450.0470 A Vtrans = 4.500470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:14 Magnet Current, Imag = 450.0400 A Vtrans = 4.500400 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:14 Magnet Current Measurement: Imag = 450.0487 +- 0.0076 A 15:38:14 Magnet current ramping to 500.0000 A... 15:38:37 Magnet Current, Imag = 500.0730 A Vtrans = 5.000730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:39 Magnet Current, Imag = 500.0600 A Vtrans = 5.000600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:40 Magnet Current, Imag = 500.0940 A Vtrans = 5.000940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:42 Magnet Current, Imag = 500.1010 A Vtrans = 5.001010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:42 Magnet Current Measurement: Imag = 500.0820 +- 0.0164 A 15:38:42 Magnetic Field Measurement Measuring the magnet strength... 15:38:42 Integrated Voltage Measurement... 15:38:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015723673 Vs 15:39:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016060111 Vs 15:39:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015726191 Vs 15:39:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016063841 Vs 15:39:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015725989 Vs 15:39:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016057069 Vs 15:40:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015742976 Vs 15:40:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016043502 Vs 15:40:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015892919 +- 0.000001368 Vs 15:40:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015892919 +- 0.000001368 Vs BL = 1.58929192 +- 0.00013681 Tm 15:40:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.58929 0.00014 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.58929 0.00014 1.58929 0.00000 15:40:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.58929 0.00014 SL = 1.5892919 +- 0.0001368 Tm^2/m^n 15:40:15 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5892919 +- 0.0001368 Tm^2/m^n 15:40:16 Magnet Current, Imag = 500.0860 A Vtrans = 5.000860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:18 Magnet Current, Imag = 500.1010 A Vtrans = 5.001010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:19 Magnet Current, Imag = 500.1030 A Vtrans = 5.001030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:21 Magnet Current, Imag = 500.1090 A Vtrans = 5.001090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:21 Magnet Current Measurement: Imag = 500.0997 +- 0.0085 A 15:40:21 Magnet current ramping to 525.0000 A... 15:40:37 Magnet Current, Imag = 525.0980 A Vtrans = 5.250980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:38 Magnet Current, Imag = 525.0980 A Vtrans = 5.250980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:40 Magnet Current, Imag = 525.1380 A Vtrans = 5.251380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:42 Magnet Current, Imag = 525.1370 A Vtrans = 5.251370 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:42 Magnet Current Measurement: Imag = 525.1177 +- 0.0198 A 15:40:42 Magnetic Field Measurement Measuring the magnet strength... 15:40:42 Integrated Voltage Measurement... 15:40:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016520007 Vs 15:41:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016848732 Vs 15:41:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016516115 Vs 15:41:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016855671 Vs 15:41:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016517689 Vs 15:41:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016837575 Vs 15:42:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016514491 Vs 15:42:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016836107 Vs 15:42:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016680798 +- 0.000004444 Vs 15:42:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016680798 +- 0.000004444 Vs BL = 1.66807985 +- 0.00044435 Tm 15:42:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.66808 0.00044 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.66808 0.00044 1.66808 0.00000 15:42:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.66808 0.00044 SL = 1.6680799 +- 0.0004444 Tm^2/m^n 15:42:14 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6680799 +- 0.0004444 Tm^2/m^n 15:42:15 Magnet Current, Imag = 525.1160 A Vtrans = 5.251160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:42:17 Magnet Current, Imag = 525.0910 A Vtrans = 5.250910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:42:19 Magnet Current, Imag = 525.0960 A Vtrans = 5.250960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:42:20 Magnet Current, Imag = 525.1000 A Vtrans = 5.251000 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:42:20 Magnet Current Measurement: Imag = 525.1007 +- 0.0094 A 15:42:21 Magnet current ramping to 550.0000 A... 15:42:36 Magnet Current, Imag = 550.0590 A Vtrans = 5.500590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:42:38 Magnet Current, Imag = 550.0610 A Vtrans = 5.500610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:42:40 Magnet Current, Imag = 550.1120 A Vtrans = 5.501120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:42:42 Magnet Current, Imag = 550.1030 A Vtrans = 5.501030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:42:42 Magnet Current Measurement: Imag = 550.0838 +- 0.0240 A 15:42:42 Magnetic Field Measurement Measuring the magnet strength... 15:42:42 Integrated Voltage Measurement... 15:42:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017314171 Vs 15:43:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017624038 Vs 15:43:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017291527 Vs 15:43:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017629481 Vs 15:43:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017295436 Vs 15:43:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017626140 Vs 15:44:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017277482 Vs 15:44:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017625804 Vs 15:44:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017460510 +- 0.000006176 Vs 15:44:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017460510 +- 0.000006176 Vs BL = 1.74605098 +- 0.00061758 Tm 15:44:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.74605 0.00062 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.74605 0.00062 1.74605 0.00000 15:44:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.74605 0.00062 SL = 1.7460510 +- 0.0006176 Tm^2/m^n 15:44:14 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7460510 +- 0.0006176 Tm^2/m^n 15:44:16 Magnet Current, Imag = 550.1150 A Vtrans = 5.501150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:44:18 Magnet Current, Imag = 550.0820 A Vtrans = 5.500820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:44:19 Magnet Current, Imag = 550.0530 A Vtrans = 5.500530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:44:21 Magnet Current, Imag = 550.0650 A Vtrans = 5.500650 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:44:21 Magnet Current Measurement: Imag = 550.0788 +- 0.0233 A 15:44:21 Magnet current ramping to 575.0000 A... 15:44:37 Magnet Current, Imag = 575.0730 A Vtrans = 5.750730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:44:38 Magnet Current, Imag = 575.0750 A Vtrans = 5.750750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:44:40 Magnet Current, Imag = 575.0870 A Vtrans = 5.750870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:44:42 Magnet Current, Imag = 575.0600 A Vtrans = 5.750600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:44:42 Magnet Current Measurement: Imag = 575.0738 +- 0.0096 A 15:44:42 Magnetic Field Measurement Measuring the magnet strength... 15:44:42 Integrated Voltage Measurement... 15:44:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018050221 Vs 15:45:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018406489 Vs 15:45:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018067787 Vs 15:45:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018402914 Vs 15:45:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018070965 Vs 15:45:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018407488 Vs 15:46:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018054763 Vs 15:46:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018404961 Vs 15:46:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018233199 +- 0.000004346 Vs 15:46:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.018233199 +- 0.000004346 Vs BL = 1.82331987 +- 0.00043463 Tm 15:46:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.82332 0.00043 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.82332 0.00043 1.82332 0.00000 15:46:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.82332 0.00043 SL = 1.8233199 +- 0.0004346 Tm^2/m^n 15:46:14 Magnet Strength Measurement Harmonic Number = 1 SL = 1.8233199 +- 0.0004346 Tm^2/m^n 15:46:16 Magnet Current, Imag = 575.1180 A Vtrans = 5.751180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:46:17 Magnet Current, Imag = 575.1120 A Vtrans = 5.751120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:46:19 Magnet Current, Imag = 575.1280 A Vtrans = 5.751280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:46:20 Magnet Current, Imag = 575.1340 A Vtrans = 5.751340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:46:21 Magnet Current Measurement: Imag = 575.1230 +- 0.0085 A 15:46:21 Magnet current ramping to 600.0000 A... 15:46:36 Magnet Current, Imag = 600.1340 A Vtrans = 6.001340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:46:38 Magnet Current, Imag = 600.1600 A Vtrans = 6.001600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:46:40 Magnet Current, Imag = 600.1100 A Vtrans = 6.001100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:46:41 Magnet Current, Imag = 600.1520 A Vtrans = 6.001520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:46:41 Magnet Current Measurement: Imag = 600.1390 +- 0.0192 A 15:46:41 Magnetic Field Measurement Measuring the magnet strength... 15:46:41 Integrated Voltage Measurement... 15:46:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018830065 Vs 15:47:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019165588 Vs 15:47:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018834304 Vs 15:47:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019150119 Vs 15:47:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018831095 Vs 15:47:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019158105 Vs 15:48:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018837918 Vs 15:48:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019131465 Vs 15:48:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018992332 +- 0.000004841 Vs 15:48:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.018992332 +- 0.000004841 Vs BL = 1.89923324 +- 0.00048405 Tm 15:48:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.89923 0.00048 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.89923 0.00048 1.89923 0.00000 15:48:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.89923 0.00048 SL = 1.8992332 +- 0.0004841 Tm^2/m^n 15:48:14 Magnet Strength Measurement Harmonic Number = 1 SL = 1.8992332 +- 0.0004841 Tm^2/m^n 15:48:15 Magnet Current, Imag = 600.1320 A Vtrans = 6.001320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:48:17 Magnet Current, Imag = 600.1530 A Vtrans = 6.001530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:48:19 Magnet Current, Imag = 600.1360 A Vtrans = 6.001360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:48:20 Magnet Current, Imag = 600.1140 A Vtrans = 6.001140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:48:20 Magnet Current Measurement: Imag = 600.1337 +- 0.0139 A 15:48:20 Magnet current ramping to 625.0000 A... 15:48:36 Magnet Current, Imag = 625.1300 A Vtrans = 6.251300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:48:38 Magnet Current, Imag = 625.1310 A Vtrans = 6.251310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:48:39 Magnet Current, Imag = 625.1360 A Vtrans = 6.251360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:48:41 Magnet Current, Imag = 625.1360 A Vtrans = 6.251360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:48:41 Magnet Current Measurement: Imag = 625.1332 +- 0.0028 A 15:48:41 Magnetic Field Measurement Measuring the magnet strength... 15:48:41 Integrated Voltage Measurement... 15:48:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019570537 Vs 15:49:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019894326 Vs 15:49:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019575082 Vs 15:49:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019897475 Vs 15:49:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019576404 Vs 15:49:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019898297 Vs 15:49:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019567143 Vs 15:50:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019890470 Vs 15:50:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019733717 +- 0.000003374 Vs 15:50:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019733717 +- 0.000003374 Vs BL = 1.97337168 +- 0.00033736 Tm 15:50:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.97337 0.00034 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.97337 0.00034 1.97337 0.00000 15:50:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.97337 0.00034 SL = 1.9733717 +- 0.0003374 Tm^2/m^n 15:50:14 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9733717 +- 0.0003374 Tm^2/m^n 15:50:15 Magnet Current, Imag = 625.0500 A Vtrans = 6.250500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:50:17 Magnet Current, Imag = 625.1080 A Vtrans = 6.251080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:50:18 Magnet Current, Imag = 625.1240 A Vtrans = 6.251240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:50:20 Magnet Current, Imag = 625.1350 A Vtrans = 6.251350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:50:20 Magnet Current Measurement: Imag = 625.1042 +- 0.0328 A 15:50:20 Magnet current ramping to 650.0000 A... 15:50:36 Magnet Current, Imag = 650.1480 A Vtrans = 6.501480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:50:38 Magnet Current, Imag = 650.1670 A Vtrans = 6.501670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:50:39 Magnet Current, Imag = 650.1540 A Vtrans = 6.501540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:50:41 Magnet Current, Imag = 650.1150 A Vtrans = 6.501150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:50:41 Magnet Current Measurement: Imag = 650.1460 +- 0.0192 A 15:50:41 Magnetic Field Measurement Measuring the magnet strength... 15:50:41 Integrated Voltage Measurement... 15:50:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020268661 Vs 15:51:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020602367 Vs 15:51:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020263917 Vs 15:51:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020588074 Vs 15:51:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020284681 Vs 15:51:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020591787 Vs 15:51:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020287155 Vs 15:52:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020612081 Vs 15:52:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020437341 +- 0.000008420 Vs 15:52:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020437341 +- 0.000008420 Vs BL = 2.04373406 +- 0.00084200 Tm 15:52:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.04373 0.00084 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.04373 0.00084 2.04373 0.00000 15:52:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.04373 0.00084 SL = 2.0437341 +- 0.0008420 Tm^2/m^n 15:52:14 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0437341 +- 0.0008420 Tm^2/m^n 15:52:15 Magnet Current, Imag = 650.1770 A Vtrans = 6.501770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:52:17 Magnet Current, Imag = 650.1550 A Vtrans = 6.501550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:52:18 Magnet Current, Imag = 650.1090 A Vtrans = 6.501090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:52:20 Magnet Current, Imag = 650.0700 A Vtrans = 6.500700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:52:20 Magnet Current Measurement: Imag = 650.1277 +- 0.0414 A 15:52:20 Magnet current ramping to 675.0000 A... 15:52:36 Magnet Current, Imag = 675.1910 A Vtrans = 6.751910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:52:37 Magnet Current, Imag = 675.2080 A Vtrans = 6.752080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:52:39 Magnet Current, Imag = 675.1240 A Vtrans = 6.751240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:52:41 Magnet Current, Imag = 675.1410 A Vtrans = 6.751410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:52:41 Magnet Current Measurement: Imag = 675.1660 +- 0.0346 A 15:52:41 Magnetic Field Measurement Measuring the magnet strength... 15:52:41 Integrated Voltage Measurement... 15:52:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020940186 Vs 15:53:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021276938 Vs 15:53:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020943449 Vs 15:53:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021260765 Vs 15:53:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020939511 Vs 15:53:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021271266 Vs 15:53:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020944051 Vs 15:54:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021260824 Vs 15:54:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021104624 +- 0.000002608 Vs 15:54:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021104624 +- 0.000002608 Vs BL = 2.11046238 +- 0.00026081 Tm 15:54:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.11046 0.00026 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.11046 0.00026 2.11046 0.00000 15:54:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.11046 0.00026 SL = 2.1104624 +- 0.0002608 Tm^2/m^n 15:54:13 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1104624 +- 0.0002608 Tm^2/m^n 15:54:15 Magnet Current, Imag = 675.2180 A Vtrans = 6.752180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:16 Magnet Current, Imag = 675.1900 A Vtrans = 6.751900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:18 Magnet Current, Imag = 675.2020 A Vtrans = 6.752020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:20 Magnet Current, Imag = 675.2030 A Vtrans = 6.752030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:20 Magnet Current Measurement: Imag = 675.2033 +- 0.0099 A 15:54:20 Magnet current ramping to 700.0000 A... 15:54:36 Magnet Current, Imag = 700.1580 A Vtrans = 7.001580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:37 Magnet Current, Imag = 700.1910 A Vtrans = 7.001910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:39 Magnet Current, Imag = 700.1980 A Vtrans = 7.001980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:40 Magnet Current, Imag = 700.1760 A Vtrans = 7.001760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:40 Magnet Current Measurement: Imag = 700.1807 +- 0.0154 A 15:54:40 Magnetic Field Measurement Measuring the magnet strength... 15:54:41 Integrated Voltage Measurement... 15:54:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021548449 Vs 15:55:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021890342 Vs 15:55:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021558967 Vs 15:55:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021895968 Vs 15:55:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021560227 Vs 15:55:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021888423 Vs 15:55:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021544616 Vs 15:56:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021880716 Vs 15:56:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021720963 +- 0.000005588 Vs 15:56:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021720963 +- 0.000005588 Vs BL = 2.17209634 +- 0.00055880 Tm 15:56:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.17210 0.00056 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.17210 0.00056 2.17210 0.00000 15:56:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.17210 0.00056 SL = 2.1720963 +- 0.0005588 Tm^2/m^n 15:56:13 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1720963 +- 0.0005588 Tm^2/m^n 15:56:14 Magnet Current, Imag = 700.1820 A Vtrans = 7.001820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:16 Magnet Current, Imag = 700.2060 A Vtrans = 7.002060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:17 Magnet Current, Imag = 700.1970 A Vtrans = 7.001970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:19 Magnet Current, Imag = 700.1910 A Vtrans = 7.001910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:19 Magnet Current Measurement: Imag = 700.1940 +- 0.0087 A 15:56:19 Magnet current ramping to 650.0000 A... 15:56:42 Magnet Current, Imag = 650.1840 A Vtrans = 6.501840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:44 Magnet Current, Imag = 650.1630 A Vtrans = 6.501630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:45 Magnet Current, Imag = 650.1720 A Vtrans = 6.501720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:47 Magnet Current, Imag = 650.1440 A Vtrans = 6.501440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:47 Magnet Current Measurement: Imag = 650.1657 +- 0.0146 A 15:56:47 Magnetic Field Measurement Measuring the magnet strength... 15:56:47 Integrated Voltage Measurement... 15:57:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020350983 Vs 15:57:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020694539 Vs 15:57:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020341442 Vs 15:57:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020689232 Vs 15:57:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020346343 Vs 15:57:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020680915 Vs 15:58:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020351459 Vs 15:58:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020688791 Vs 15:58:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020517963 +- 0.000003653 Vs 15:58:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020517963 +- 0.000003653 Vs BL = 2.05179628 +- 0.00036527 Tm 15:58:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.05180 0.00037 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.05180 0.00037 2.05180 0.00000 15:58:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.05180 0.00037 SL = 2.0517963 +- 0.0003653 Tm^2/m^n 15:58:19 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0517963 +- 0.0003653 Tm^2/m^n 15:58:21 Magnet Current, Imag = 650.1850 A Vtrans = 6.501850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:58:23 Magnet Current, Imag = 650.1740 A Vtrans = 6.501740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:58:24 Magnet Current, Imag = 650.1790 A Vtrans = 6.501790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:58:26 Magnet Current, Imag = 650.1760 A Vtrans = 6.501760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:58:26 Magnet Current Measurement: Imag = 650.1785 +- 0.0042 A 15:58:26 Magnet current ramping to 600.0000 A... 15:58:49 Magnet Current, Imag = 600.1270 A Vtrans = 6.001270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:58:51 Magnet Current, Imag = 600.1140 A Vtrans = 6.001140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:58:52 Magnet Current, Imag = 600.0950 A Vtrans = 6.000950 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:58:54 Magnet Current, Imag = 600.1450 A Vtrans = 6.001450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:58:54 Magnet Current Measurement: Imag = 600.1202 +- 0.0183 A 15:58:54 Magnetic Field Measurement Measuring the magnet strength... 15:58:54 Integrated Voltage Measurement... 15:59:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018921319 Vs 15:59:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019234534 Vs 15:59:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018925107 Vs 15:59:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019243603 Vs 15:59:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018913768 Vs 16:00:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019240566 Vs 16:00:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018929038 Vs 16:00:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019234549 Vs 16:00:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019080310 +- 0.000002921 Vs 16:00:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019080310 +- 0.000002921 Vs BL = 1.90803104 +- 0.00029207 Tm 16:00:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.90803 0.00029 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.90803 0.00029 1.90803 0.00000 16:00:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.90803 0.00029 SL = 1.9080310 +- 0.0002921 Tm^2/m^n 16:00:26 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9080310 +- 0.0002921 Tm^2/m^n 16:00:28 Magnet Current, Imag = 600.1010 A Vtrans = 6.001010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:00:29 Magnet Current, Imag = 600.1490 A Vtrans = 6.001490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:00:31 Magnet Current, Imag = 600.1610 A Vtrans = 6.001610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:00:32 Magnet Current, Imag = 600.1420 A Vtrans = 6.001420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:00:32 Magnet Current Measurement: Imag = 600.1382 +- 0.0226 A 16:00:33 Magnet current ramping to 550.0000 A... 16:00:56 Magnet Current, Imag = 550.1010 A Vtrans = 5.501010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:00:57 Magnet Current, Imag = 550.0930 A Vtrans = 5.500930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:00:59 Magnet Current, Imag = 550.0660 A Vtrans = 5.500660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:01:01 Magnet Current, Imag = 550.0660 A Vtrans = 5.500660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:01:01 Magnet Current Measurement: Imag = 550.0815 +- 0.0158 A 16:01:01 Magnetic Field Measurement Measuring the magnet strength... 16:01:01 Integrated Voltage Measurement... 16:01:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017377875 Vs 16:01:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017688949 Vs 16:01:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017366157 Vs 16:01:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017693153 Vs 16:01:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017375795 Vs 16:02:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017683151 Vs 16:02:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017384755 Vs 16:02:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017705004 Vs 16:02:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017534355 +- 0.000006277 Vs 16:02:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017534355 +- 0.000006277 Vs BL = 1.75343549 +- 0.00062766 Tm 16:02:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.75344 0.00063 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.75344 0.00063 1.75344 0.00000 16:02:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.75344 0.00063 SL = 1.7534355 +- 0.0006277 Tm^2/m^n 16:02:32 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7534355 +- 0.0006277 Tm^2/m^n 16:02:34 Magnet Current, Imag = 550.1400 A Vtrans = 5.501400 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:02:36 Magnet Current, Imag = 550.1190 A Vtrans = 5.501190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:02:37 Magnet Current, Imag = 550.1110 A Vtrans = 5.501110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:02:39 Magnet Current, Imag = 550.1010 A Vtrans = 5.501010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:02:39 Magnet Current Measurement: Imag = 550.1178 +- 0.0143 A 16:02:39 Magnet current ramping to 500.0000 A... 16:03:02 Magnet Current, Imag = 500.1450 A Vtrans = 5.001450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:04 Magnet Current, Imag = 500.1410 A Vtrans = 5.001410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:05 Magnet Current, Imag = 500.1350 A Vtrans = 5.001350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:07 Magnet Current, Imag = 500.1130 A Vtrans = 5.001130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:07 Magnet Current Measurement: Imag = 500.1335 +- 0.0124 A 16:03:07 Magnetic Field Measurement Measuring the magnet strength... 16:03:07 Integrated Voltage Measurement... 16:03:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015807385 Vs 16:03:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016124267 Vs 16:03:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015796977 Vs 16:03:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016129042 Vs 16:04:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015807119 Vs 16:04:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016118058 Vs 16:04:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015801093 Vs 16:04:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016117657 Vs 16:04:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015962700 +- 0.000002288 Vs 16:04:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015962700 +- 0.000002288 Vs BL = 1.59626998 +- 0.00022877 Tm 16:04:39 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.59627 0.00023 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.59627 0.00023 1.59627 0.00000 16:04:39 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.59627 0.00023 SL = 1.5962700 +- 0.0002288 Tm^2/m^n 16:04:39 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5962700 +- 0.0002288 Tm^2/m^n 16:04:41 Magnet Current, Imag = 500.0980 A Vtrans = 5.000980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:04:43 Magnet Current, Imag = 500.1070 A Vtrans = 5.001070 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:04:44 Magnet Current, Imag = 500.1370 A Vtrans = 5.001370 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:04:46 Magnet Current, Imag = 500.1020 A Vtrans = 5.001020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:04:46 Magnet Current Measurement: Imag = 500.1110 +- 0.0153 A 16:04:46 Magnet current ramping to 450.0000 A... 16:05:09 Magnet Current, Imag = 450.0730 A Vtrans = 4.500730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:11 Magnet Current, Imag = 450.0560 A Vtrans = 4.500560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:12 Magnet Current, Imag = 450.0320 A Vtrans = 4.500320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:14 Magnet Current, Imag = 450.0320 A Vtrans = 4.500320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:14 Magnet Current Measurement: Imag = 450.0482 +- 0.0173 A 16:05:14 Magnetic Field Measurement Measuring the magnet strength... 16:05:14 Integrated Voltage Measurement... 16:05:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014196459 Vs 16:05:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014535723 Vs 16:05:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014199445 Vs 16:06:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014545501 Vs 16:06:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014202425 Vs 16:06:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014545783 Vs 16:06:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014202293 Vs 16:06:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014533915 Vs 16:06:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014370193 +- 0.000003228 Vs 16:06:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014370193 +- 0.000003228 Vs BL = 1.43701929 +- 0.00032282 Tm 16:06:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43702 0.00032 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.43702 0.00032 1.43702 0.00000 16:06:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43702 0.00032 SL = 1.4370193 +- 0.0003228 Tm^2/m^n 16:06:47 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4370193 +- 0.0003228 Tm^2/m^n 16:06:49 Magnet Current, Imag = 450.0600 A Vtrans = 4.500600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:06:50 Magnet Current, Imag = 450.0560 A Vtrans = 4.500560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:06:52 Magnet Current, Imag = 450.0270 A Vtrans = 4.500270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:06:53 Magnet Current, Imag = 449.9910 A Vtrans = 4.499910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:06:53 Magnet Current Measurement: Imag = 450.0335 +- 0.0276 A 16:06:54 Magnet current ramping to 400.0000 A... 16:07:17 Magnet Current, Imag = 400.0350 A Vtrans = 4.000350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:19 Magnet Current, Imag = 400.0060 A Vtrans = 4.000060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:20 Magnet Current, Imag = 400.0170 A Vtrans = 4.000170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:22 Magnet Current, Imag = 400.0010 A Vtrans = 4.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:22 Magnet Current Measurement: Imag = 400.0147 +- 0.0130 A 16:07:22 Magnetic Field Measurement Measuring the magnet strength... 16:07:22 Integrated Voltage Measurement... 16:07:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012611271 Vs 16:07:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012927491 Vs 16:07:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012624185 Vs 16:08:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012936043 Vs 16:08:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012613084 Vs 16:08:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012943755 Vs 16:08:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012613702 Vs 16:08:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012951984 Vs 16:08:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012777689 +- 0.000005050 Vs 16:08:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012777689 +- 0.000005050 Vs BL = 1.27776893 +- 0.00050499 Tm 16:08:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.27777 0.00050 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.27777 0.00050 1.27777 0.00000 16:08:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.27777 0.00050 SL = 1.2777689 +- 0.0005050 Tm^2/m^n 16:08:55 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2777689 +- 0.0005050 Tm^2/m^n 16:08:56 Magnet Current, Imag = 399.9910 A Vtrans = 3.999910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:08:58 Magnet Current, Imag = 400.0020 A Vtrans = 4.000020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:08:59 Magnet Current, Imag = 400.0220 A Vtrans = 4.000220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:01 Magnet Current, Imag = 400.0250 A Vtrans = 4.000250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:01 Magnet Current Measurement: Imag = 400.0100 +- 0.0141 A 16:09:31 Magnet current ramping to 0.0000 A...