SLAC Magnetic Measurements Date: 08-20-2001 Time: 11:25:08 Project: spear3 Magnet Type: gdipole Magnet Name: 145d-015 Serial Number: Run Number: 10 Measurement Device: stretched wire Operator: jy Comment: BL vs. I, trims Test Currents (A): -12.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 11:25:18 Initial Zero Current Measurement, Imag_zero = 0.0000 A 11:25:48 Magnet current ramping to -12.0000 A... 11:26:39 Magnet Current, Imag = -12.1156 A Vtrans = -0.121156 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:26:40 Magnet Current, Imag = -12.1152 A Vtrans = -0.121152 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:26:42 Magnet Current, Imag = -12.1149 A Vtrans = -0.121149 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:26:44 Magnet Current, Imag = -12.1145 A Vtrans = -0.121146 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:26:44 Magnet Current Measurement: Imag = -12.1151 +- 0.0004 A 11:26:44 Magnetic Field Measurement Measuring the magnet strength... 11:26:45 Integrated Voltage Measurement... 11:26:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000369994 Vs 11:27:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000392925 Vs 11:27:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000369395 Vs 11:27:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000392098 Vs 11:27:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000370175 Vs 11:27:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000392053 Vs 11:28:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000370512 Vs 11:28:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000390847 Vs 11:28:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000381000 +- 0.000000313 Vs 11:28:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000381000 +- 0.000000313 Vs BL = -0.03809998 +- 0.00003127 Tm 11:28:16 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.03810 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.03810 0.00003 -0.03810 0.00000 11:28:16 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.03810 0.00003 SL = -0.0381000 +- 0.0000313 Tm^2/m^n 11:28:16 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0381000 +- 0.0000313 Tm^2/m^n 11:28:18 Magnet Current, Imag = -12.1052 A Vtrans = -0.121052 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:28:20 Magnet Current, Imag = -12.1051 A Vtrans = -0.121051 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:28:22 Magnet Current, Imag = -12.1048 A Vtrans = -0.121048 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:28:24 Magnet Current, Imag = -12.1049 A Vtrans = -0.121049 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:28:24 Magnet Current Measurement: Imag = -12.1050 +- 0.0002 A 11:28:24 Magnet current ramping to -10.0000 A... 11:28:40 Magnet Current, Imag = -10.0591 A Vtrans = -0.100591 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:28:42 Magnet Current, Imag = -10.0592 A Vtrans = -0.100592 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:28:44 Magnet Current, Imag = -10.0592 A Vtrans = -0.100592 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:28:46 Magnet Current, Imag = -10.0591 A Vtrans = -0.100591 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:28:46 Magnet Current Measurement: Imag = -10.0592 +- 0.0000 A 11:28:46 Magnetic Field Measurement Measuring the magnet strength... 11:28:46 Integrated Voltage Measurement... 11:29:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000303177 Vs 11:29:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000324512 Vs 11:29:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000302473 Vs 11:29:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000324464 Vs 11:29:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000302865 Vs 11:29:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000324804 Vs 11:30:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000302556 Vs 11:30:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000323963 Vs 11:30:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000313602 +- 0.000000249 Vs 11:30:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000313602 +- 0.000000249 Vs BL = -0.03136019 +- 0.00002490 Tm 11:30:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.03136 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.03136 0.00002 -0.03136 0.00000 11:30:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.03136 0.00002 SL = -0.0313602 +- 0.0000249 Tm^2/m^n 11:30:18 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0313602 +- 0.0000249 Tm^2/m^n 11:30:20 Magnet Current, Imag = -10.0590 A Vtrans = -0.100590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:30:22 Magnet Current, Imag = -10.0591 A Vtrans = -0.100591 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:30:24 Magnet Current, Imag = -10.0591 A Vtrans = -0.100591 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:30:26 Magnet Current, Imag = -10.0591 A Vtrans = -0.100591 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:30:26 Magnet Current Measurement: Imag = -10.0591 +- 0.0000 A 11:30:26 Magnet current ramping to -8.0000 A... 11:30:42 Magnet Current, Imag = -8.0298 A Vtrans = -0.080298 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:30:44 Magnet Current, Imag = -8.0298 A Vtrans = -0.080298 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:30:46 Magnet Current, Imag = -8.0300 A Vtrans = -0.080300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:30:48 Magnet Current, Imag = -8.0299 A Vtrans = -0.080299 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:30:48 Magnet Current Measurement: Imag = -8.0299 +- 0.0001 A 11:30:48 Magnetic Field Measurement Measuring the magnet strength... 11:30:48 Integrated Voltage Measurement... 11:31:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000237301 Vs 11:31:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000256306 Vs 11:31:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000236789 Vs 11:31:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000256735 Vs 11:31:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000236158 Vs 11:31:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000256937 Vs 11:32:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000237504 Vs 11:32:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000256451 Vs 11:32:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000246773 +- 0.000000153 Vs 11:32:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000246773 +- 0.000000153 Vs BL = -0.02467727 +- 0.00001532 Tm 11:32:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02468 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.02468 0.00002 -0.02468 0.00000 11:32:20 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02468 0.00002 SL = -0.0246773 +- 0.0000153 Tm^2/m^n 11:32:20 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0246773 +- 0.0000153 Tm^2/m^n 11:32:22 Magnet Current, Imag = -8.0311 A Vtrans = -0.080311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:32:24 Magnet Current, Imag = -8.0311 A Vtrans = -0.080311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:32:26 Magnet Current, Imag = -8.0311 A Vtrans = -0.080311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:32:28 Magnet Current, Imag = -8.0312 A Vtrans = -0.080312 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:32:28 Magnet Current Measurement: Imag = -8.0311 +- 0.0000 A 11:32:28 Magnet current ramping to -6.0000 A... 11:32:44 Magnet Current, Imag = -6.0006 A Vtrans = -0.060006 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:32:46 Magnet Current, Imag = -6.0007 A Vtrans = -0.060007 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:32:48 Magnet Current, Imag = -6.0007 A Vtrans = -0.060007 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:32:50 Magnet Current, Imag = -6.0007 A Vtrans = -0.060007 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:32:50 Magnet Current Measurement: Imag = -6.0007 +- 0.0000 A 11:32:50 Magnetic Field Measurement Measuring the magnet strength... 11:32:50 Integrated Voltage Measurement... 11:33:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000169824 Vs 11:33:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000188917 Vs 11:33:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000169760 Vs 11:33:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000188449 Vs 11:33:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000170716 Vs 11:33:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000188987 Vs 11:34:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000170039 Vs 11:34:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000188496 Vs 11:34:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000179399 +- 0.000000278 Vs 11:34:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000179399 +- 0.000000278 Vs BL = -0.01793985 +- 0.00002783 Tm 11:34:21 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01794 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.01794 0.00003 -0.01794 0.00000 11:34:21 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01794 0.00003 SL = -0.0179399 +- 0.0000278 Tm^2/m^n 11:34:21 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0179399 +- 0.0000278 Tm^2/m^n 11:34:23 Magnet Current, Imag = -6.0017 A Vtrans = -0.060017 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:34:25 Magnet Current, Imag = -6.0017 A Vtrans = -0.060017 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:34:27 Magnet Current, Imag = -6.0013 A Vtrans = -0.060013 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:34:29 Magnet Current, Imag = -6.0016 A Vtrans = -0.060016 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:34:29 Magnet Current Measurement: Imag = -6.0016 +- 0.0002 A 11:34:30 Magnet current ramping to -4.0000 A... 11:34:46 Magnet Current, Imag = -3.9712 A Vtrans = -0.039712 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:34:48 Magnet Current, Imag = -3.9711 A Vtrans = -0.039711 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:34:50 Magnet Current, Imag = -3.9712 A Vtrans = -0.039712 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:34:52 Magnet Current, Imag = -3.9712 A Vtrans = -0.039712 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:34:52 Magnet Current Measurement: Imag = -3.9712 +- 0.0001 A 11:34:52 Magnetic Field Measurement Measuring the magnet strength... 11:34:52 Integrated Voltage Measurement... 11:35:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000103393 Vs 11:35:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000120573 Vs 11:35:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000102955 Vs 11:35:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000121138 Vs 11:35:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000102397 Vs 11:35:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000120255 Vs 11:36:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000103105 Vs 11:36:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000121002 Vs 11:36:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000111852 +- 0.000000305 Vs 11:36:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000111852 +- 0.000000305 Vs BL = -0.01118520 +- 0.00003051 Tm 11:36:23 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01119 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.01119 0.00003 -0.01119 0.00000 11:36:23 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01119 0.00003 SL = -0.0111852 +- 0.0000305 Tm^2/m^n 11:36:23 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0111852 +- 0.0000305 Tm^2/m^n 11:36:25 Magnet Current, Imag = -3.9718 A Vtrans = -0.039718 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:36:27 Magnet Current, Imag = -3.9718 A Vtrans = -0.039718 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:36:29 Magnet Current, Imag = -3.9717 A Vtrans = -0.039717 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:36:31 Magnet Current, Imag = -3.9719 A Vtrans = -0.039719 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:36:31 Magnet Current Measurement: Imag = -3.9718 +- 0.0000 A 11:36:31 Magnet current ramping to -2.0000 A... 11:36:47 Magnet Current, Imag = -1.9411 A Vtrans = -0.019411 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:36:49 Magnet Current, Imag = -1.9413 A Vtrans = -0.019413 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:36:51 Magnet Current, Imag = -1.9413 A Vtrans = -0.019413 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:36:53 Magnet Current, Imag = -1.9411 A Vtrans = -0.019411 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:36:53 Magnet Current Measurement: Imag = -1.9412 +- 0.0001 A 11:36:54 Magnetic Field Measurement Measuring the magnet strength... 11:36:54 Integrated Voltage Measurement... 11:37:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000035041 Vs 11:37:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000053486 Vs 11:37:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000035657 Vs 11:37:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000052803 Vs 11:37:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000035779 Vs 11:38:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000053223 Vs 11:38:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000036301 Vs 11:38:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000053238 Vs 11:38:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000044441 +- 0.000000216 Vs 11:38:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000044441 +- 0.000000216 Vs BL = -0.00444410 +- 0.00002164 Tm 11:38:25 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00444 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00444 0.00002 -0.00444 0.00000 11:38:25 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00444 0.00002 SL = -0.0044441 +- 0.0000216 Tm^2/m^n 11:38:25 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0044441 +- 0.0000216 Tm^2/m^n 11:38:27 Magnet Current, Imag = -1.9416 A Vtrans = -0.019416 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:38:29 Magnet Current, Imag = -1.9415 A Vtrans = -0.019415 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:38:31 Magnet Current, Imag = -1.9411 A Vtrans = -0.019411 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:38:33 Magnet Current, Imag = -1.9415 A Vtrans = -0.019415 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:38:33 Magnet Current Measurement: Imag = -1.9414 +- 0.0002 A 11:38:52 Magnet current ramping to 0.0000 A... 11:39:08 Magnet Current, Imag = 0.0906 A Vtrans = 0.000906 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:39:10 Magnet Current, Imag = 0.0906 A Vtrans = 0.000906 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:39:12 Magnet Current, Imag = 0.0907 A Vtrans = 0.000907 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:39:15 Magnet Current, Imag = 0.0905 A Vtrans = 0.000905 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:39:15 Magnet Current Measurement: Imag = 0.0906 +- 0.0000 A 11:39:15 Magnetic Field Measurement Measuring the magnet strength... 11:39:15 Integrated Voltage Measurement... 11:39:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000032478 Vs 11:39:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000015055 Vs 11:39:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000031951 Vs 11:40:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000015683 Vs 11:40:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000030976 Vs 11:40:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000016391 Vs 11:40:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000032262 Vs 11:40:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000016525 Vs 11:40:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000023915 +- 0.000000280 Vs 11:40:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000023915 +- 0.000000280 Vs BL = 0.00239150 +- 0.00002804 Tm 11:40:46 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00239 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00239 0.00003 0.00239 0.00000 11:40:46 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00239 0.00003 SL = 0.0023915 +- 0.0000280 Tm^2/m^n 11:40:46 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0023915 +- 0.0000280 Tm^2/m^n 11:40:48 Magnet Current, Imag = 0.0906 A Vtrans = 0.000906 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:40:50 Magnet Current, Imag = 0.0904 A Vtrans = 0.000904 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:40:52 Magnet Current, Imag = 0.0906 A Vtrans = 0.000906 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:40:54 Magnet Current, Imag = 0.0903 A Vtrans = 0.000903 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:40:54 Magnet Current Measurement: Imag = 0.0905 +- 0.0001 A 11:40:54 Magnet current ramping to 2.0000 A... 11:41:10 Magnet Current, Imag = 2.1225 A Vtrans = 0.021225 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:41:12 Magnet Current, Imag = 2.1225 A Vtrans = 0.021225 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:41:14 Magnet Current, Imag = 2.1223 A Vtrans = 0.021223 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:41:16 Magnet Current, Imag = 2.1223 A Vtrans = 0.021223 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:41:16 Magnet Current Measurement: Imag = 2.1224 +- 0.0001 A 11:41:17 Magnetic Field Measurement Measuring the magnet strength... 11:41:17 Integrated Voltage Measurement... 11:41:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000098585 Vs 11:41:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000083207 Vs 11:41:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000100066 Vs 11:42:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000083477 Vs 11:42:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000099381 Vs 11:42:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000083973 Vs 11:42:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000099816 Vs 11:42:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000084090 Vs 11:42:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000091574 +- 0.000000404 Vs 11:42:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000091574 +- 0.000000404 Vs BL = 0.00915744 +- 0.00004040 Tm 11:42:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00916 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00916 0.00004 0.00916 0.00000 11:42:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00916 0.00004 SL = 0.0091574 +- 0.0000404 Tm^2/m^n 11:42:48 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0091574 +- 0.0000404 Tm^2/m^n 11:42:50 Magnet Current, Imag = 2.1221 A Vtrans = 0.021221 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:42:52 Magnet Current, Imag = 2.1222 A Vtrans = 0.021222 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:42:54 Magnet Current, Imag = 2.1222 A Vtrans = 0.021222 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:42:56 Magnet Current, Imag = 2.1221 A Vtrans = 0.021221 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:42:56 Magnet Current Measurement: Imag = 2.1221 +- 0.0000 A 11:42:56 Magnet current ramping to 4.0000 A... 11:43:12 Magnet Current, Imag = 4.1534 A Vtrans = 0.041534 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:43:14 Magnet Current, Imag = 4.1534 A Vtrans = 0.041534 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:43:16 Magnet Current, Imag = 4.1531 A Vtrans = 0.041531 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:43:18 Magnet Current, Imag = 4.1534 A Vtrans = 0.041534 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:43:18 Magnet Current Measurement: Imag = 4.1533 +- 0.0001 A 11:43:19 Magnetic Field Measurement Measuring the magnet strength... 11:43:19 Integrated Voltage Measurement... 11:43:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000167503 Vs 11:43:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000152211 Vs 11:43:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000166371 Vs 11:44:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000152343 Vs 11:44:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000167499 Vs 11:44:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000151815 Vs 11:44:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000167295 Vs 11:44:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000152775 Vs 11:44:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000159727 +- 0.000000252 Vs 11:44:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000159727 +- 0.000000252 Vs BL = 0.01597266 +- 0.00002518 Tm 11:44:50 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.01597 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.01597 0.00003 0.01597 0.00000 11:44:50 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.01597 0.00003 SL = 0.0159727 +- 0.0000252 Tm^2/m^n 11:44:50 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0159727 +- 0.0000252 Tm^2/m^n 11:44:52 Magnet Current, Imag = 4.1528 A Vtrans = 0.041528 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:44:54 Magnet Current, Imag = 4.1528 A Vtrans = 0.041528 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:44:56 Magnet Current, Imag = 4.1527 A Vtrans = 0.041527 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:44:58 Magnet Current, Imag = 4.1528 A Vtrans = 0.041528 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:44:58 Magnet Current Measurement: Imag = 4.1528 +- 0.0000 A 11:44:58 Magnet current ramping to 6.0000 A... 11:45:14 Magnet Current, Imag = 6.1838 A Vtrans = 0.061838 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:45:16 Magnet Current, Imag = 6.1837 A Vtrans = 0.061837 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:45:18 Magnet Current, Imag = 6.1836 A Vtrans = 0.061836 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:45:20 Magnet Current, Imag = 6.1836 A Vtrans = 0.061836 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:45:20 Magnet Current Measurement: Imag = 6.1837 +- 0.0001 A 11:45:20 Magnetic Field Measurement Measuring the magnet strength... 11:45:20 Integrated Voltage Measurement... 11:45:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000235366 Vs 11:45:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000220152 Vs 11:45:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000235891 Vs 11:46:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000220558 Vs 11:46:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000235613 Vs 11:46:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000221035 Vs 11:46:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000235004 Vs 11:46:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000221104 Vs 11:46:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000228090 +- 0.000000214 Vs 11:46:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000228090 +- 0.000000214 Vs BL = 0.02280904 +- 0.00002144 Tm 11:46:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.02281 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.02281 0.00002 0.02281 0.00000 11:46:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.02281 0.00002 SL = 0.0228090 +- 0.0000214 Tm^2/m^n 11:46:52 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0228090 +- 0.0000214 Tm^2/m^n 11:46:54 Magnet Current, Imag = 6.1822 A Vtrans = 0.061822 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:46:56 Magnet Current, Imag = 6.1822 A Vtrans = 0.061822 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:46:58 Magnet Current, Imag = 6.1822 A Vtrans = 0.061822 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:47:00 Magnet Current, Imag = 6.1822 A Vtrans = 0.061822 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:47:00 Magnet Current Measurement: Imag = 6.1822 +- 0.0000 A 11:47:01 Magnet current ramping to 8.0000 A... 11:47:17 Magnet Current, Imag = 8.2127 A Vtrans = 0.082127 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:47:19 Magnet Current, Imag = 8.2126 A Vtrans = 0.082126 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:47:21 Magnet Current, Imag = 8.2124 A Vtrans = 0.082124 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:47:23 Magnet Current, Imag = 8.2122 A Vtrans = 0.082122 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:47:23 Magnet Current Measurement: Imag = 8.2125 +- 0.0002 A 11:47:23 Magnetic Field Measurement Measuring the magnet strength... 11:47:23 Integrated Voltage Measurement... 11:47:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000303579 Vs 11:47:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000290747 Vs 11:47:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000302113 Vs 11:48:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000290921 Vs 11:48:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000301963 Vs 11:48:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000290741 Vs 11:48:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000300821 Vs 11:48:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000289607 Vs 11:48:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000296311 +- 0.000000702 Vs 11:48:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000296311 +- 0.000000702 Vs BL = 0.02963114 +- 0.00007024 Tm 11:48:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.02963 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.02963 0.00007 0.02963 0.00000 11:48:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.02963 0.00007 SL = 0.0296311 +- 0.0000702 Tm^2/m^n 11:48:55 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0296311 +- 0.0000702 Tm^2/m^n 11:48:57 Magnet Current, Imag = 8.2103 A Vtrans = 0.082103 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:48:59 Magnet Current, Imag = 8.2103 A Vtrans = 0.082103 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:49:01 Magnet Current, Imag = 8.2103 A Vtrans = 0.082103 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:49:03 Magnet Current, Imag = 8.2103 A Vtrans = 0.082103 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:49:03 Magnet Current Measurement: Imag = 8.2103 +- 0.0000 A 11:49:03 Magnet current ramping to 10.0000 A... 11:49:19 Magnet Current, Imag = 10.2391 A Vtrans = 0.102391 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:49:21 Magnet Current, Imag = 10.2389 A Vtrans = 0.102389 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:49:23 Magnet Current, Imag = 10.2385 A Vtrans = 0.102385 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:49:25 Magnet Current, Imag = 10.2384 A Vtrans = 0.102384 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:49:25 Magnet Current Measurement: Imag = 10.2387 +- 0.0003 A 11:49:25 Magnetic Field Measurement Measuring the magnet strength... 11:49:25 Integrated Voltage Measurement... 11:49:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000370827 Vs 11:49:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000357400 Vs 11:50:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000369669 Vs 11:50:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000358859 Vs 11:50:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000369807 Vs 11:50:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000359104 Vs 11:50:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000369430 Vs 11:50:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000359546 Vs 11:50:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000364330 +- 0.000000152 Vs 11:50:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000364330 +- 0.000000152 Vs BL = 0.03643302 +- 0.00001517 Tm 11:50:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.03643 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.03643 0.00002 0.03643 0.00000 11:50:56 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.03643 0.00002 SL = 0.0364330 +- 0.0000152 Tm^2/m^n 11:50:57 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0364330 +- 0.0000152 Tm^2/m^n 11:50:59 Magnet Current, Imag = 10.2355 A Vtrans = 0.102355 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:51:00 Magnet Current, Imag = 10.2354 A Vtrans = 0.102354 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:51:02 Magnet Current, Imag = 10.2354 A Vtrans = 0.102354 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:51:04 Magnet Current, Imag = 10.2354 A Vtrans = 0.102354 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:51:04 Magnet Current Measurement: Imag = 10.2354 +- 0.0001 A 11:51:05 Magnet current ramping to 12.0000 A... 11:51:21 Magnet Current, Imag = 12.2636 A Vtrans = 0.122636 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:51:23 Magnet Current, Imag = 12.2634 A Vtrans = 0.122634 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:51:24 Magnet Current, Imag = 12.2630 A Vtrans = 0.122630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:51:26 Magnet Current, Imag = 12.2627 A Vtrans = 0.122627 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:51:26 Magnet Current Measurement: Imag = 12.2632 +- 0.0003 A 11:51:27 Magnetic Field Measurement Measuring the magnet strength... 11:51:27 Integrated Voltage Measurement... 11:51:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000437293 Vs 11:51:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000427508 Vs 11:52:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000438128 Vs 11:52:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000427833 Vs 11:52:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000438062 Vs 11:52:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000427386 Vs 11:52:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000438675 Vs 11:52:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000426041 Vs 11:52:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000432616 +- 0.000000254 Vs 11:52:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000432616 +- 0.000000254 Vs BL = 0.04326157 +- 0.00002537 Tm 11:52:58 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.04326 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.04326 0.00003 0.04326 0.00000 11:52:58 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.04326 0.00003 SL = 0.0432616 +- 0.0000254 Tm^2/m^n 11:52:59 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0432616 +- 0.0000254 Tm^2/m^n 11:53:00 Magnet Current, Imag = 12.2587 A Vtrans = 0.122587 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:53:02 Magnet Current, Imag = 12.2587 A Vtrans = 0.122587 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:53:04 Magnet Current, Imag = 12.2585 A Vtrans = 0.122586 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:53:06 Magnet Current, Imag = 12.2586 A Vtrans = 0.122586 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:53:06 Magnet Current Measurement: Imag = 12.2586 +- 0.0001 A 11:53:37 Magnet current ramping to 0.0000 A...