SLAC Magnetic Measurements Date: 07-18-2001 Time: 10:13:03 Project: spear3 Magnet Type: gdipole Magnet Name: 145d-014 Serial Number: Run Number: 10 Measurement Device: stretched wire Operator: jy Comment: BL vs. I, mains--10STDZ cycles Standardization: 10 cycles from 0.0 A to 770.0 A to 0.0 A Test Currents (A): 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 500.0 525.0 550.0 575.0 600.0 625.0 650.0 675.0 700.0 650.0 600.0 550.0 500.0 450.0 400.0 10:13:12 Initial Zero Current Measurement, Imag_zero = 0.0000 A 10:13:12 Magnet current ramping to 15.0000 A... 10:13:44 Magnet current ramping to 770.0000 A... 10:18:01 Magnet current ramping to 0.0000 A... 10:22:22 Magnet current ramping to 770.0000 A... 10:26:44 Magnet current ramping to 0.0000 A... 10:31:05 Magnet current ramping to 770.0000 A... 10:35:27 Magnet current ramping to 0.0000 A... 10:39:48 Magnet current ramping to 770.0000 A... 10:44:10 Magnet current ramping to 0.0000 A... 10:48:31 Magnet current ramping to 770.0000 A... 10:52:53 Magnet current ramping to 0.0000 A... 10:57:13 Magnet current ramping to 770.0000 A... 11:01:36 Magnet current ramping to 0.0000 A... 11:05:57 Magnet current ramping to 770.0000 A... 11:10:19 Magnet current ramping to 0.0000 A... 11:14:40 Magnet current ramping to 770.0000 A... 11:19:02 Magnet current ramping to 0.0000 A... 11:23:23 Magnet current ramping to 770.0000 A... 11:27:45 Magnet current ramping to 0.0000 A... 11:32:06 Magnet current ramping to 770.0000 A... 11:36:29 Magnet current ramping to 0.0000 A... 11:41:21 Magnet current ramping to 50.0000 A... 11:41:44 Magnet Current, Imag = 51.1106 A Vtrans = 0.511106 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:41:46 Magnet Current, Imag = 51.5761 A Vtrans = 0.515761 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:41:47 Magnet Current, Imag = 48.9408 A Vtrans = 0.489408 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:41:49 Magnet Current, Imag = 49.8674 A Vtrans = 0.498674 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:41:49 Magnet Current Measurement: Imag = 50.3737 +- 1.0366 A 11:41:49 Magnetic Field Measurement Measuring the magnet strength... 11:41:49 Integrated Voltage Measurement... 11:42:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001595154 Vs 11:42:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001606131 Vs 11:42:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001602735 Vs 11:42:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001591871 Vs 11:42:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001615839 Vs 11:42:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001603587 Vs 11:43:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001598863 Vs 11:43:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001601695 Vs 11:43:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001601985 +- 0.000004647 Vs 11:43:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001601985 +- 0.000004647 Vs BL = 0.16019845 +- 0.00046465 Tm 11:43:21 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.16020 0.00046 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.16020 0.00046 0.16020 0.00000 11:43:21 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.16020 0.00046 SL = 0.1601984 +- 0.0004647 Tm^2/m^n 11:43:21 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1601984 +- 0.0004647 Tm^2/m^n 11:43:23 Magnet Current, Imag = 49.9535 A Vtrans = 0.499535 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:43:24 Magnet Current, Imag = 49.9305 A Vtrans = 0.499305 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:43:26 Magnet Current, Imag = 49.9322 A Vtrans = 0.499322 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:43:27 Magnet Current, Imag = 49.9443 A Vtrans = 0.499443 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:43:27 Magnet Current Measurement: Imag = 49.9401 +- 0.0094 A 11:43:28 Magnet current ramping to 100.0000 A... 11:43:50 Magnet Current, Imag = 99.9729 A Vtrans = 0.999729 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:43:52 Magnet Current, Imag = 99.9819 A Vtrans = 0.999819 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:43:53 Magnet Current, Imag = 99.9895 A Vtrans = 0.999895 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:43:55 Magnet Current, Imag = 99.9722 A Vtrans = 0.999722 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:43:55 Magnet Current Measurement: Imag = 99.9791 +- 0.0071 A 11:43:55 Magnetic Field Measurement Measuring the magnet strength... 11:43:55 Integrated Voltage Measurement... 11:44:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003177995 Vs 11:44:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003173919 Vs 11:44:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003179110 Vs 11:44:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003177827 Vs 11:44:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003191408 Vs 11:45:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003191157 Vs 11:45:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003172127 Vs 11:45:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003190056 Vs 11:45:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003181700 +- 0.000005823 Vs 11:45:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.003181700 +- 0.000005823 Vs BL = 0.31817000 +- 0.00058226 Tm 11:45:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.31817 0.00058 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.31817 0.00058 0.31817 0.00000 11:45:27 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.31817 0.00058 SL = 0.3181700 +- 0.0005823 Tm^2/m^n 11:45:27 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3181700 +- 0.0005823 Tm^2/m^n 11:45:29 Magnet Current, Imag = 99.9694 A Vtrans = 0.999694 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:45:30 Magnet Current, Imag = 99.9685 A Vtrans = 0.999685 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:45:31 Magnet Current, Imag = 99.9872 A Vtrans = 0.999872 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:45:33 Magnet Current, Imag = 99.9845 A Vtrans = 0.999845 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:45:33 Magnet Current Measurement: Imag = 99.9774 +- 0.0085 A 11:45:33 Magnet current ramping to 150.0000 A... 11:45:56 Magnet Current, Imag = 150.0089 A Vtrans = 1.500089 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:45:58 Magnet Current, Imag = 150.0094 A Vtrans = 1.500094 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:45:59 Magnet Current, Imag = 150.0043 A Vtrans = 1.500043 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:46:01 Magnet Current, Imag = 150.0274 A Vtrans = 1.500274 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:46:01 Magnet Current Measurement: Imag = 150.0125 +- 0.0088 A 11:46:01 Magnetic Field Measurement Measuring the magnet strength... 11:46:01 Integrated Voltage Measurement... 11:46:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004785178 Vs 11:46:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004769239 Vs 11:46:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004767911 Vs 11:46:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004739621 Vs 11:46:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004770127 Vs 11:47:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004773253 Vs 11:47:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004766516 Vs 11:47:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004770160 Vs 11:47:31 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004767751 +- 0.000008673 Vs 11:47:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004767751 +- 0.000008673 Vs BL = 0.47677506 +- 0.00086730 Tm 11:47:34 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.47678 0.00087 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.47678 0.00087 0.47678 0.00000 11:47:34 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.47678 0.00087 SL = 0.4767751 +- 0.0008673 Tm^2/m^n 11:47:34 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4767751 +- 0.0008673 Tm^2/m^n 11:47:35 Magnet Current, Imag = 149.9919 A Vtrans = 1.499919 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:47:37 Magnet Current, Imag = 149.9935 A Vtrans = 1.499935 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:47:38 Magnet Current, Imag = 150.0115 A Vtrans = 1.500115 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:47:40 Magnet Current, Imag = 149.9948 A Vtrans = 1.499948 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:47:40 Magnet Current Measurement: Imag = 149.9979 +- 0.0079 A 11:47:40 Magnet current ramping to 200.0000 A... 11:48:03 Magnet Current, Imag = 199.9778 A Vtrans = 1.999778 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:48:05 Magnet Current, Imag = 199.9702 A Vtrans = 1.999702 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:48:06 Magnet Current, Imag = 199.9804 A Vtrans = 1.999804 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:48:08 Magnet Current, Imag = 199.9980 A Vtrans = 1.999980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:48:08 Magnet Current Measurement: Imag = 199.9816 +- 0.0102 A 11:48:08 Magnetic Field Measurement Measuring the magnet strength... 11:48:08 Integrated Voltage Measurement... 11:48:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006369218 Vs 11:48:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006380206 Vs 11:48:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006365279 Vs 11:48:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006364549 Vs 11:49:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006356807 Vs 11:49:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006363129 Vs 11:49:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006375631 Vs 11:49:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006364857 Vs 11:49:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006367460 +- 0.000005544 Vs 11:49:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006367460 +- 0.000005544 Vs BL = 0.63674596 +- 0.00055442 Tm 11:49:40 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.63675 0.00055 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.63675 0.00055 0.63675 0.00000 11:49:40 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.63675 0.00055 SL = 0.6367460 +- 0.0005544 Tm^2/m^n 11:49:40 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6367460 +- 0.0005544 Tm^2/m^n 11:49:41 Magnet Current, Imag = 199.9794 A Vtrans = 1.999794 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:49:43 Magnet Current, Imag = 199.9876 A Vtrans = 1.999876 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:49:44 Magnet Current, Imag = 199.9913 A Vtrans = 1.999913 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:49:46 Magnet Current, Imag = 199.9989 A Vtrans = 1.999989 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:49:46 Magnet Current Measurement: Imag = 199.9893 +- 0.0070 A 11:49:46 Magnet current ramping to 250.0000 A... 11:50:09 Magnet Current, Imag = 250.0187 A Vtrans = 2.500187 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:50:11 Magnet Current, Imag = 250.0160 A Vtrans = 2.500160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:50:12 Magnet Current, Imag = 250.0245 A Vtrans = 2.500245 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:50:14 Magnet Current, Imag = 250.0054 A Vtrans = 2.500054 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:50:14 Magnet Current Measurement: Imag = 250.0161 +- 0.0069 A 11:50:14 Magnetic Field Measurement Measuring the magnet strength... 11:50:14 Integrated Voltage Measurement... 11:50:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007963257 Vs 11:50:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007947545 Vs 11:50:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007953215 Vs 11:50:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007948165 Vs 11:51:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007954265 Vs 11:51:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007968901 Vs 11:51:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007962696 Vs 11:51:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007964513 Vs 11:51:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007957820 +- 0.000005107 Vs 11:51:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.007957820 +- 0.000005107 Vs BL = 0.79578197 +- 0.00051066 Tm 11:51:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.79578 0.00051 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.79578 0.00051 0.79578 0.00000 11:51:46 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.79578 0.00051 SL = 0.7957820 +- 0.0005107 Tm^2/m^n 11:51:46 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7957820 +- 0.0005107 Tm^2/m^n 11:51:47 Magnet Current, Imag = 250.0257 A Vtrans = 2.500257 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:51:49 Magnet Current, Imag = 250.0319 A Vtrans = 2.500319 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:51:50 Magnet Current, Imag = 250.0394 A Vtrans = 2.500394 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:51:52 Magnet Current, Imag = 250.0255 A Vtrans = 2.500255 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:51:52 Magnet Current Measurement: Imag = 250.0306 +- 0.0057 A 11:51:52 Magnet current ramping to 300.0000 A... 11:52:15 Magnet Current, Imag = 300.0470 A Vtrans = 3.000470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:52:16 Magnet Current, Imag = 300.0657 A Vtrans = 3.000657 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:52:18 Magnet Current, Imag = 300.0404 A Vtrans = 3.000404 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:52:19 Magnet Current, Imag = 300.0400 A Vtrans = 3.000400 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:52:19 Magnet Current Measurement: Imag = 300.0483 +- 0.0104 A 11:52:20 Magnetic Field Measurement Measuring the magnet strength... 11:52:20 Integrated Voltage Measurement... 11:52:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009557679 Vs 11:52:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009537383 Vs 11:52:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009549927 Vs 11:53:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009541607 Vs 11:53:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009549055 Vs 11:53:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009551812 Vs 11:53:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009548799 Vs 11:53:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009536686 Vs 11:53:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009546619 +- 0.000002790 Vs 11:53:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009546619 +- 0.000002790 Vs BL = 0.95466186 +- 0.00027900 Tm 11:53:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.95466 0.00028 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.95466 0.00028 0.95466 0.00000 11:53:51 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.95466 0.00028 SL = 0.9546619 +- 0.0002790 Tm^2/m^n 11:53:52 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9546619 +- 0.0002790 Tm^2/m^n 11:53:53 Magnet Current, Imag = 300.0572 A Vtrans = 3.000572 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:53:55 Magnet Current, Imag = 300.0634 A Vtrans = 3.000634 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:53:56 Magnet Current, Imag = 300.0543 A Vtrans = 3.000543 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:53:57 Magnet Current, Imag = 300.0636 A Vtrans = 3.000636 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:53:58 Magnet Current Measurement: Imag = 300.0596 +- 0.0040 A 11:53:58 Magnet current ramping to 350.0000 A... 11:54:21 Magnet Current, Imag = 350.0780 A Vtrans = 3.500780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:54:23 Magnet Current, Imag = 350.1240 A Vtrans = 3.501240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:54:25 Magnet Current, Imag = 350.1160 A Vtrans = 3.501160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:54:27 Magnet Current, Imag = 350.1200 A Vtrans = 3.501200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:54:27 Magnet Current Measurement: Imag = 350.1095 +- 0.0184 A 11:54:27 Magnetic Field Measurement Measuring the magnet strength... 11:54:27 Integrated Voltage Measurement... 11:54:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011148497 Vs 11:54:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011147533 Vs 11:55:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011142051 Vs 11:55:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011119095 Vs 11:55:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011151277 Vs 11:55:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011130669 Vs 11:55:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011160246 Vs 11:55:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011147384 Vs 11:55:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011143344 +- 0.000008663 Vs 11:55:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.011143344 +- 0.000008663 Vs BL = 1.11433443 +- 0.00086628 Tm 11:55:59 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.11433 0.00087 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.11433 0.00087 1.11433 0.00000 11:55:59 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.11433 0.00087 SL = 1.1143344 +- 0.0008663 Tm^2/m^n 11:55:59 Magnet Strength Measurement Harmonic Number = 1 SL = 1.1143344 +- 0.0008663 Tm^2/m^n 11:56:01 Magnet Current, Imag = 350.1020 A Vtrans = 3.501020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:56:03 Magnet Current, Imag = 350.0930 A Vtrans = 3.500930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:56:05 Magnet Current, Imag = 350.0630 A Vtrans = 3.500630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:56:07 Magnet Current, Imag = 350.0610 A Vtrans = 3.500610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:56:07 Magnet Current Measurement: Imag = 350.0797 +- 0.0180 A 11:56:07 Magnet current ramping to 400.0000 A... 11:56:31 Magnet Current, Imag = 400.0910 A Vtrans = 4.000910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:56:33 Magnet Current, Imag = 400.1110 A Vtrans = 4.001110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:56:34 Magnet Current, Imag = 400.0830 A Vtrans = 4.000830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:56:36 Magnet Current, Imag = 400.0780 A Vtrans = 4.000780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:56:36 Magnet Current Measurement: Imag = 400.0907 +- 0.0126 A 11:56:36 Magnetic Field Measurement Measuring the magnet strength... 11:56:36 Integrated Voltage Measurement... 11:56:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012725387 Vs 11:57:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012722239 Vs 11:57:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012738042 Vs 11:57:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012746228 Vs 11:57:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012726005 Vs 11:57:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012727745 Vs 11:57:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012726311 Vs 11:58:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012739775 Vs 11:58:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012731467 +- 0.000006999 Vs 11:58:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012731467 +- 0.000006999 Vs BL = 1.27314666 +- 0.00069992 Tm 11:58:08 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.27315 0.00070 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.27315 0.00070 1.27315 0.00000 11:58:08 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.27315 0.00070 SL = 1.2731467 +- 0.0006999 Tm^2/m^n 11:58:08 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2731467 +- 0.0006999 Tm^2/m^n 11:58:10 Magnet Current, Imag = 400.0820 A Vtrans = 4.000820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:58:11 Magnet Current, Imag = 400.0900 A Vtrans = 4.000900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:58:13 Magnet Current, Imag = 400.0640 A Vtrans = 4.000640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:58:14 Magnet Current, Imag = 400.0760 A Vtrans = 4.000760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:58:14 Magnet Current Measurement: Imag = 400.0780 +- 0.0095 A 11:58:15 Magnet current ramping to 450.0000 A... 11:58:38 Magnet Current, Imag = 450.1050 A Vtrans = 4.501050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:58:40 Magnet Current, Imag = 450.0960 A Vtrans = 4.500960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:58:41 Magnet Current, Imag = 450.1260 A Vtrans = 4.501260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:58:43 Magnet Current, Imag = 450.1250 A Vtrans = 4.501250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:58:43 Magnet Current Measurement: Imag = 450.1130 +- 0.0129 A 11:58:43 Magnetic Field Measurement Measuring the magnet strength... 11:58:43 Integrated Voltage Measurement... 11:58:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014326037 Vs 11:59:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014325907 Vs 11:59:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014330827 Vs 11:59:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014324363 Vs 11:59:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014306511 Vs 11:59:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014318223 Vs 12:00:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014303987 Vs 12:00:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014343657 Vs 12:00:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014322439 +- 0.000005967 Vs 12:00:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014322439 +- 0.000005967 Vs BL = 1.43224390 +- 0.00059671 Tm 12:00:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43224 0.00060 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.43224 0.00060 1.43224 0.00000 12:00:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43224 0.00060 SL = 1.4322439 +- 0.0005967 Tm^2/m^n 12:00:15 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4322439 +- 0.0005967 Tm^2/m^n 12:00:17 Magnet Current, Imag = 450.1200 A Vtrans = 4.501200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:00:18 Magnet Current, Imag = 450.1330 A Vtrans = 4.501330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:00:20 Magnet Current, Imag = 450.1240 A Vtrans = 4.501240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:00:21 Magnet Current, Imag = 450.1160 A Vtrans = 4.501160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:00:22 Magnet Current Measurement: Imag = 450.1232 +- 0.0063 A 12:00:22 Magnet current ramping to 500.0000 A... 12:00:45 Magnet Current, Imag = 500.1490 A Vtrans = 5.001490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:00:47 Magnet Current, Imag = 500.1630 A Vtrans = 5.001630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:00:48 Magnet Current, Imag = 500.1700 A Vtrans = 5.001700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:00:50 Magnet Current, Imag = 500.1790 A Vtrans = 5.001790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:00:50 Magnet Current Measurement: Imag = 500.1653 +- 0.0110 A 12:00:50 Magnetic Field Measurement Measuring the magnet strength... 12:00:50 Integrated Voltage Measurement... 12:01:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015899667 Vs 12:01:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015911549 Vs 12:01:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015905201 Vs 12:01:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015903273 Vs 12:01:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015917383 Vs 12:01:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015898433 Vs 12:02:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015920404 Vs 12:02:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015889405 Vs 12:02:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015905664 +- 0.000001383 Vs 12:02:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015905664 +- 0.000001383 Vs BL = 1.59056643 +- 0.00013832 Tm 12:02:23 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.59057 0.00014 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.59057 0.00014 1.59057 0.00000 12:02:23 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.59057 0.00014 SL = 1.5905664 +- 0.0001383 Tm^2/m^n 12:02:23 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5905664 +- 0.0001383 Tm^2/m^n 12:02:25 Magnet Current, Imag = 500.1240 A Vtrans = 5.001240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:02:26 Magnet Current, Imag = 500.1560 A Vtrans = 5.001560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:02:28 Magnet Current, Imag = 500.1350 A Vtrans = 5.001350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:02:30 Magnet Current, Imag = 500.1410 A Vtrans = 5.001410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:02:30 Magnet Current Measurement: Imag = 500.1390 +- 0.0116 A 12:02:30 Magnet current ramping to 525.0000 A... 12:02:46 Magnet Current, Imag = 525.1630 A Vtrans = 5.251630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:02:47 Magnet Current, Imag = 525.1640 A Vtrans = 5.251640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:02:49 Magnet Current, Imag = 525.1740 A Vtrans = 5.251740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:02:50 Magnet Current, Imag = 525.1460 A Vtrans = 5.251460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:02:50 Magnet Current Measurement: Imag = 525.1617 +- 0.0101 A 12:02:50 Magnetic Field Measurement Measuring the magnet strength... 12:02:51 Integrated Voltage Measurement... 12:03:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016706737 Vs 12:03:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016690482 Vs 12:03:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016699619 Vs 12:03:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016698979 Vs 12:03:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016711789 Vs 12:03:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016709534 Vs 12:04:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016695285 Vs 12:04:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016698769 Vs 12:04:19 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016701399 +- 0.000005411 Vs 12:04:19 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016701399 +- 0.000005411 Vs BL = 1.67013992 +- 0.00054105 Tm 12:04:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.67014 0.00054 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.67014 0.00054 1.67014 0.00000 12:04:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.67014 0.00054 SL = 1.6701399 +- 0.0005411 Tm^2/m^n 12:04:22 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6701399 +- 0.0005411 Tm^2/m^n 12:04:24 Magnet Current, Imag = 525.1930 A Vtrans = 5.251930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:04:26 Magnet Current, Imag = 525.1940 A Vtrans = 5.251940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:04:27 Magnet Current, Imag = 525.1840 A Vtrans = 5.251840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:04:29 Magnet Current, Imag = 525.1860 A Vtrans = 5.251860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:04:29 Magnet Current Measurement: Imag = 525.1892 +- 0.0043 A 12:04:29 Magnet current ramping to 550.0000 A... 12:04:45 Magnet Current, Imag = 550.1080 A Vtrans = 5.501080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:04:46 Magnet Current, Imag = 550.1220 A Vtrans = 5.501220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:04:48 Magnet Current, Imag = 550.1880 A Vtrans = 5.501880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:04:50 Magnet Current, Imag = 550.1860 A Vtrans = 5.501860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:04:50 Magnet Current Measurement: Imag = 550.1510 +- 0.0363 A 12:04:50 Magnetic Field Measurement Measuring the magnet strength... 12:04:50 Integrated Voltage Measurement... 12:05:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017483271 Vs 12:05:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017481370 Vs 12:05:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017478279 Vs 12:05:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017485673 Vs 12:05:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017477201 Vs 12:05:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017485720 Vs 12:06:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017471079 Vs 12:06:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017481739 Vs 12:06:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017480542 +- 0.000002405 Vs 12:06:19 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017480542 +- 0.000002405 Vs BL = 1.74805415 +- 0.00024055 Tm 12:06:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.74805 0.00024 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.74805 0.00024 1.74805 0.00000 12:06:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.74805 0.00024 SL = 1.7480542 +- 0.0002405 Tm^2/m^n 12:06:22 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7480542 +- 0.0002405 Tm^2/m^n 12:06:23 Magnet Current, Imag = 550.1230 A Vtrans = 5.501230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:06:25 Magnet Current, Imag = 550.1160 A Vtrans = 5.501160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:06:27 Magnet Current, Imag = 550.0890 A Vtrans = 5.500890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:06:28 Magnet Current, Imag = 550.0900 A Vtrans = 5.500900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:06:28 Magnet Current Measurement: Imag = 550.1045 +- 0.0152 A 12:06:28 Magnet current ramping to 575.0000 A... 12:06:44 Magnet Current, Imag = 575.1260 A Vtrans = 5.751260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:06:46 Magnet Current, Imag = 575.1170 A Vtrans = 5.751170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:06:47 Magnet Current, Imag = 575.1680 A Vtrans = 5.751680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:06:49 Magnet Current, Imag = 575.1610 A Vtrans = 5.751610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:06:49 Magnet Current Measurement: Imag = 575.1430 +- 0.0219 A 12:06:49 Magnetic Field Measurement Measuring the magnet strength... 12:06:49 Integrated Voltage Measurement... 12:07:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018257039 Vs 12:07:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018247441 Vs 12:07:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018258933 Vs 12:07:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018255923 Vs 12:07:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018239894 Vs 12:07:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018265067 Vs 12:08:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018229283 Vs 12:08:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018245235 Vs 12:08:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018249852 +- 0.000007560 Vs 12:08:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.018249852 +- 0.000007560 Vs BL = 1.82498520 +- 0.00075597 Tm 12:08:21 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.82499 0.00076 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.82499 0.00076 1.82499 0.00000 12:08:21 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.82499 0.00076 SL = 1.8249852 +- 0.0007560 Tm^2/m^n 12:08:21 Magnet Strength Measurement Harmonic Number = 1 SL = 1.8249852 +- 0.0007560 Tm^2/m^n 12:08:23 Magnet Current, Imag = 575.1420 A Vtrans = 5.751420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:08:24 Magnet Current, Imag = 575.1240 A Vtrans = 5.751240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:08:26 Magnet Current, Imag = 575.1390 A Vtrans = 5.751390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:08:28 Magnet Current, Imag = 575.1640 A Vtrans = 5.751640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:08:28 Magnet Current Measurement: Imag = 575.1423 +- 0.0143 A 12:08:28 Magnet current ramping to 600.0000 A... 12:08:44 Magnet Current, Imag = 600.1890 A Vtrans = 6.001890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:08:45 Magnet Current, Imag = 600.1740 A Vtrans = 6.001740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:08:47 Magnet Current, Imag = 600.1750 A Vtrans = 6.001750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:08:48 Magnet Current, Imag = 600.1660 A Vtrans = 6.001660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:08:48 Magnet Current Measurement: Imag = 600.1760 +- 0.0083 A 12:08:49 Magnetic Field Measurement Measuring the magnet strength... 12:08:49 Integrated Voltage Measurement... 12:09:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019020347 Vs 12:09:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019033147 Vs 12:09:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019012669 Vs 12:09:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019023949 Vs 12:09:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019006197 Vs 12:09:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018999471 Vs 12:10:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019009829 Vs 12:10:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019006927 Vs 12:10:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019014067 +- 0.000009183 Vs 12:10:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019014067 +- 0.000009183 Vs BL = 1.90140671 +- 0.00091831 Tm 12:10:21 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.90141 0.00092 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.90141 0.00092 1.90141 0.00000 12:10:21 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.90141 0.00092 SL = 1.9014067 +- 0.0009183 Tm^2/m^n 12:10:21 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9014067 +- 0.0009183 Tm^2/m^n 12:10:22 Magnet Current, Imag = 600.1810 A Vtrans = 6.001810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:10:24 Magnet Current, Imag = 600.1670 A Vtrans = 6.001670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:10:26 Magnet Current, Imag = 600.1870 A Vtrans = 6.001870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:10:27 Magnet Current, Imag = 600.1580 A Vtrans = 6.001580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:10:27 Magnet Current Measurement: Imag = 600.1732 +- 0.0114 A 12:10:27 Magnet current ramping to 625.0000 A... 12:10:43 Magnet Current, Imag = 625.1960 A Vtrans = 6.251960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:10:45 Magnet Current, Imag = 625.2130 A Vtrans = 6.252130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:10:46 Magnet Current, Imag = 625.2030 A Vtrans = 6.252030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:10:48 Magnet Current, Imag = 625.2290 A Vtrans = 6.252290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:10:48 Magnet Current Measurement: Imag = 625.2102 +- 0.0124 A 12:10:48 Magnetic Field Measurement Measuring the magnet strength... 12:10:48 Integrated Voltage Measurement... 12:11:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019754009 Vs 12:11:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019759047 Vs 12:11:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019762605 Vs 12:11:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019765910 Vs 12:11:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019756510 Vs 12:11:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019747645 Vs 12:12:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019760429 Vs 12:12:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019763647 Vs 12:12:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019758725 +- 0.000004759 Vs 12:12:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019758725 +- 0.000004759 Vs BL = 1.97587253 +- 0.00047592 Tm 12:12:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.97587 0.00048 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.97587 0.00048 1.97587 0.00000 12:12:21 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.97587 0.00048 SL = 1.9758725 +- 0.0004759 Tm^2/m^n 12:12:21 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9758725 +- 0.0004759 Tm^2/m^n 12:12:22 Magnet Current, Imag = 625.1800 A Vtrans = 6.251800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:12:24 Magnet Current, Imag = 625.1990 A Vtrans = 6.251990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:12:25 Magnet Current, Imag = 625.2050 A Vtrans = 6.252050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:12:27 Magnet Current, Imag = 625.2240 A Vtrans = 6.252240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:12:27 Magnet Current Measurement: Imag = 625.2020 +- 0.0157 A 12:12:27 Magnet current ramping to 650.0000 A... 12:12:43 Magnet Current, Imag = 650.2310 A Vtrans = 6.502310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:12:45 Magnet Current, Imag = 650.1970 A Vtrans = 6.501970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:12:46 Magnet Current, Imag = 650.1310 A Vtrans = 6.501310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:12:48 Magnet Current, Imag = 650.1800 A Vtrans = 6.501800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:12:48 Magnet Current Measurement: Imag = 650.1847 +- 0.0361 A 12:12:48 Magnetic Field Measurement Measuring the magnet strength... 12:12:48 Integrated Voltage Measurement... 12:13:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020475672 Vs 12:13:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020456921 Vs 12:13:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020471926 Vs 12:13:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020480841 Vs 12:13:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020453603 Vs 12:13:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020464119 Vs 12:14:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020456505 Vs 12:14:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020450157 Vs 12:14:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020463718 +- 0.000008639 Vs 12:14:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020463718 +- 0.000008639 Vs BL = 2.04637179 +- 0.00086393 Tm 12:14:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.04637 0.00086 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.04637 0.00086 2.04637 0.00000 12:14:20 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.04637 0.00086 SL = 2.0463718 +- 0.0008639 Tm^2/m^n 12:14:20 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0463718 +- 0.0008639 Tm^2/m^n 12:14:22 Magnet Current, Imag = 650.1760 A Vtrans = 6.501760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:14:23 Magnet Current, Imag = 650.1610 A Vtrans = 6.501610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:14:25 Magnet Current, Imag = 650.1560 A Vtrans = 6.501560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:14:26 Magnet Current, Imag = 650.2060 A Vtrans = 6.502060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:14:27 Magnet Current Measurement: Imag = 650.1747 +- 0.0195 A 12:14:27 Magnet current ramping to 675.0000 A... 12:14:42 Magnet Current, Imag = 675.2030 A Vtrans = 6.752030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:14:44 Magnet Current, Imag = 675.1970 A Vtrans = 6.751970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:14:46 Magnet Current, Imag = 675.2060 A Vtrans = 6.752060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:14:47 Magnet Current, Imag = 675.1770 A Vtrans = 6.751770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:14:47 Magnet Current Measurement: Imag = 675.1957 +- 0.0113 A 12:14:47 Magnetic Field Measurement Measuring the magnet strength... 12:14:47 Integrated Voltage Measurement... 12:15:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021135819 Vs 12:15:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021130037 Vs 12:15:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021123604 Vs 12:15:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021126817 Vs 12:15:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021113911 Vs 12:15:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021116729 Vs 12:16:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021119553 Vs 12:16:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021120409 Vs 12:16:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021123360 +- 0.000006539 Vs 12:16:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021123360 +- 0.000006539 Vs BL = 2.11233599 +- 0.00065390 Tm 12:16:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.11234 0.00065 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.11234 0.00065 2.11234 0.00000 12:16:20 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.11234 0.00065 SL = 2.1123360 +- 0.0006539 Tm^2/m^n 12:16:20 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1123360 +- 0.0006539 Tm^2/m^n 12:16:21 Magnet Current, Imag = 675.2540 A Vtrans = 6.752540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:16:23 Magnet Current, Imag = 675.2330 A Vtrans = 6.752330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:16:24 Magnet Current, Imag = 675.2160 A Vtrans = 6.752160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:16:26 Magnet Current, Imag = 675.2190 A Vtrans = 6.752190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:16:26 Magnet Current Measurement: Imag = 675.2305 +- 0.0150 A 12:16:26 Magnet current ramping to 700.0000 A... 12:16:42 Magnet Current, Imag = 700.2310 A Vtrans = 7.002310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:16:43 Magnet Current, Imag = 700.2750 A Vtrans = 7.002750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:16:45 Magnet Current, Imag = 700.2410 A Vtrans = 7.002410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:16:47 Magnet Current, Imag = 700.1990 A Vtrans = 7.001990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:16:47 Magnet Current Measurement: Imag = 700.2365 +- 0.0271 A 12:16:47 Magnetic Field Measurement Measuring the magnet strength... 12:16:47 Integrated Voltage Measurement... 12:17:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021732972 Vs 12:17:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021746755 Vs 12:17:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021745817 Vs 12:17:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021735557 Vs 12:17:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021755396 Vs 12:17:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021739449 Vs 12:18:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021734014 Vs 12:18:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021739000 Vs 12:18:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021741120 +- 0.000003961 Vs 12:18:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021741120 +- 0.000003961 Vs BL = 2.17411199 +- 0.00039612 Tm 12:18:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.17411 0.00040 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.17411 0.00040 2.17411 0.00000 12:18:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.17411 0.00040 SL = 2.1741120 +- 0.0003961 Tm^2/m^n 12:18:19 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1741120 +- 0.0003961 Tm^2/m^n 12:18:21 Magnet Current, Imag = 700.2050 A Vtrans = 7.002050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:18:22 Magnet Current, Imag = 700.2100 A Vtrans = 7.002100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:18:24 Magnet Current, Imag = 700.2690 A Vtrans = 7.002690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:18:25 Magnet Current, Imag = 700.2180 A Vtrans = 7.002180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:18:25 Magnet Current Measurement: Imag = 700.2255 +- 0.0255 A 12:18:26 Magnet current ramping to 650.0000 A... 12:18:49 Magnet Current, Imag = 650.1530 A Vtrans = 6.501530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:18:51 Magnet Current, Imag = 650.1740 A Vtrans = 6.501740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:18:52 Magnet Current, Imag = 650.1420 A Vtrans = 6.501420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:18:54 Magnet Current, Imag = 650.1760 A Vtrans = 6.501760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:18:54 Magnet Current Measurement: Imag = 650.1612 +- 0.0143 A 12:18:54 Magnetic Field Measurement Measuring the magnet strength... 12:18:54 Integrated Voltage Measurement... 12:19:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020544022 Vs 12:19:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020545871 Vs 12:19:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020548092 Vs 12:19:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020541445 Vs 12:19:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020541737 Vs 12:20:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020544608 Vs 12:20:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020520110 Vs 12:20:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020540250 Vs 12:20:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020540767 +- 0.000006151 Vs 12:20:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020540767 +- 0.000006151 Vs BL = 2.05407669 +- 0.00061513 Tm 12:20:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.05408 0.00062 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.05408 0.00062 2.05408 0.00000 12:20:27 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.05408 0.00062 SL = 2.0540767 +- 0.0006151 Tm^2/m^n 12:20:27 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0540767 +- 0.0006151 Tm^2/m^n 12:20:28 Magnet Current, Imag = 650.1920 A Vtrans = 6.501920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:20:30 Magnet Current, Imag = 650.2100 A Vtrans = 6.502100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:20:31 Magnet Current, Imag = 650.2480 A Vtrans = 6.502480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:20:33 Magnet Current, Imag = 650.2390 A Vtrans = 6.502390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:20:33 Magnet Current Measurement: Imag = 650.2223 +- 0.0224 A 12:20:33 Magnet current ramping to 600.0000 A... 12:20:57 Magnet Current, Imag = 600.1530 A Vtrans = 6.001530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:20:58 Magnet Current, Imag = 600.1510 A Vtrans = 6.001510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:21:00 Magnet Current, Imag = 600.1550 A Vtrans = 6.001550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:21:01 Magnet Current, Imag = 600.1620 A Vtrans = 6.001620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:21:01 Magnet Current Measurement: Imag = 600.1553 +- 0.0041 A 12:21:02 Magnetic Field Measurement Measuring the magnet strength... 12:21:02 Integrated Voltage Measurement... 12:21:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019108869 Vs 12:21:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019079533 Vs 12:21:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019098640 Vs 12:21:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019099632 Vs 12:21:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019092477 Vs 12:22:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019100049 Vs 12:22:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019112093 Vs 12:22:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019087551 Vs 12:22:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019097355 +- 0.000002258 Vs 12:22:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019097355 +- 0.000002258 Vs BL = 1.90973554 +- 0.00022582 Tm 12:22:34 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.90974 0.00023 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.90974 0.00023 1.90974 0.00000 12:22:34 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.90974 0.00023 SL = 1.9097355 +- 0.0002258 Tm^2/m^n 12:22:34 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9097355 +- 0.0002258 Tm^2/m^n 12:22:35 Magnet Current, Imag = 600.1380 A Vtrans = 6.001380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:22:37 Magnet Current, Imag = 600.1630 A Vtrans = 6.001630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:22:39 Magnet Current, Imag = 600.1670 A Vtrans = 6.001670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:22:40 Magnet Current, Imag = 600.1480 A Vtrans = 6.001480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:22:40 Magnet Current Measurement: Imag = 600.1540 +- 0.0116 A 12:22:40 Magnet current ramping to 550.0000 A... 12:23:04 Magnet Current, Imag = 550.1310 A Vtrans = 5.501310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:23:05 Magnet Current, Imag = 550.1380 A Vtrans = 5.501380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:23:07 Magnet Current, Imag = 550.1190 A Vtrans = 5.501190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:23:09 Magnet Current, Imag = 550.1150 A Vtrans = 5.501150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:23:09 Magnet Current Measurement: Imag = 550.1257 +- 0.0092 A 12:23:09 Magnetic Field Measurement Measuring the magnet strength... 12:23:09 Integrated Voltage Measurement... 12:23:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017556391 Vs 12:23:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017553573 Vs 12:23:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017551268 Vs 12:23:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017549706 Vs 12:24:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017539333 Vs 12:24:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017557468 Vs 12:24:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017549692 Vs 12:24:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017550813 Vs 12:24:38 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017551030 +- 0.000002420 Vs 12:24:38 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017551030 +- 0.000002420 Vs BL = 1.75510304 +- 0.00024204 Tm 12:24:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.75510 0.00024 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.75510 0.00024 1.75510 0.00000 12:24:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.75510 0.00024 SL = 1.7551030 +- 0.0002420 Tm^2/m^n 12:24:41 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7551030 +- 0.0002420 Tm^2/m^n 12:24:43 Magnet Current, Imag = 550.1230 A Vtrans = 5.501230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:24:44 Magnet Current, Imag = 550.1330 A Vtrans = 5.501330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:24:46 Magnet Current, Imag = 550.1160 A Vtrans = 5.501160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:24:47 Magnet Current, Imag = 550.0680 A Vtrans = 5.500680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:24:48 Magnet Current Measurement: Imag = 550.1100 +- 0.0250 A 12:24:48 Magnet current ramping to 500.0000 A... 12:25:11 Magnet Current, Imag = 500.1570 A Vtrans = 5.001570 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:13 Magnet Current, Imag = 500.1630 A Vtrans = 5.001630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:14 Magnet Current, Imag = 500.1030 A Vtrans = 5.001030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:16 Magnet Current, Imag = 500.1050 A Vtrans = 5.001050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:16 Magnet Current Measurement: Imag = 500.1320 +- 0.0281 A 12:25:16 Magnetic Field Measurement Measuring the magnet strength... 12:25:16 Integrated Voltage Measurement... 12:25:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015965167 Vs 12:25:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015967471 Vs 12:25:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015987977 Vs 12:26:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015984858 Vs 12:26:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015967072 Vs 12:26:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015980770 Vs 12:26:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015956976 Vs 12:26:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015971211 Vs 12:26:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015972688 +- 0.000008724 Vs 12:26:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015972688 +- 0.000008724 Vs BL = 1.59726878 +- 0.00087241 Tm 12:26:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.59727 0.00087 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.59727 0.00087 1.59727 0.00000 12:26:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.59727 0.00087 SL = 1.5972688 +- 0.0008724 Tm^2/m^n 12:26:49 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5972688 +- 0.0008724 Tm^2/m^n 12:26:50 Magnet Current, Imag = 500.1460 A Vtrans = 5.001460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:26:52 Magnet Current, Imag = 500.0960 A Vtrans = 5.000960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:26:53 Magnet Current, Imag = 500.1180 A Vtrans = 5.001180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:26:55 Magnet Current, Imag = 500.1040 A Vtrans = 5.001040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:26:55 Magnet Current Measurement: Imag = 500.1160 +- 0.0190 A 12:26:55 Magnet current ramping to 450.0000 A... 12:27:19 Magnet Current, Imag = 450.0990 A Vtrans = 4.500990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:20 Magnet Current, Imag = 450.0700 A Vtrans = 4.500700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:22 Magnet Current, Imag = 450.0770 A Vtrans = 4.500770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:23 Magnet Current, Imag = 450.1010 A Vtrans = 4.501010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:23 Magnet Current Measurement: Imag = 450.0868 +- 0.0135 A 12:27:23 Magnetic Field Measurement Measuring the magnet strength... 12:27:24 Integrated Voltage Measurement... 12:27:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014367967 Vs 12:27:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014402627 Vs 12:27:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014373047 Vs 12:28:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014394753 Vs 12:28:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014375185 Vs 12:28:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014391968 Vs 12:28:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014378727 Vs 12:28:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014392374 Vs 12:28:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014384581 +- 0.000000855 Vs 12:28:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014384581 +- 0.000000855 Vs BL = 1.43845810 +- 0.00008553 Tm 12:28:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43846 0.00009 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.43846 0.00009 1.43846 0.00000 12:28:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43846 0.00009 SL = 1.4384581 +- 0.0000855 Tm^2/m^n 12:28:55 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4384581 +- 0.0000855 Tm^2/m^n 12:28:57 Magnet Current, Imag = 450.0990 A Vtrans = 4.500990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:28:59 Magnet Current, Imag = 450.1340 A Vtrans = 4.501340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:00 Magnet Current, Imag = 450.1070 A Vtrans = 4.501070 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:02 Magnet Current, Imag = 450.1260 A Vtrans = 4.501260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:02 Magnet Current Measurement: Imag = 450.1165 +- 0.0141 A 12:29:02 Magnet current ramping to 400.0000 A... 12:29:25 Magnet Current, Imag = 400.1060 A Vtrans = 4.001060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:27 Magnet Current, Imag = 400.0900 A Vtrans = 4.000900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:29 Magnet Current, Imag = 400.0770 A Vtrans = 4.000770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:30 Magnet Current, Imag = 400.0850 A Vtrans = 4.000850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:30 Magnet Current Measurement: Imag = 400.0895 +- 0.0106 A 12:29:30 Magnetic Field Measurement Measuring the magnet strength... 12:29:30 Integrated Voltage Measurement... 12:29:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012796611 Vs 12:29:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012791719 Vs 12:30:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012779960 Vs 12:30:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012801213 Vs 12:30:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012781014 Vs 12:30:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012788703 Vs 12:30:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012788077 Vs 12:30:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012781841 Vs 12:30:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012788642 +- 0.000003942 Vs 12:30:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012788642 +- 0.000003942 Vs BL = 1.27886422 +- 0.00039422 Tm 12:31:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.27886 0.00039 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.27886 0.00039 1.27886 0.00000 12:31:02 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.27886 0.00039 SL = 1.2788642 +- 0.0003942 Tm^2/m^n 12:31:02 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2788642 +- 0.0003942 Tm^2/m^n 12:31:04 Magnet Current, Imag = 400.0650 A Vtrans = 4.000650 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:06 Magnet Current, Imag = 400.0490 A Vtrans = 4.000490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:07 Magnet Current, Imag = 400.0670 A Vtrans = 4.000670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:09 Magnet Current, Imag = 400.0670 A Vtrans = 4.000670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:09 Magnet Current Measurement: Imag = 400.0620 +- 0.0075 A 12:31:39 Magnet current ramping to 0.0000 A...