SLAC Magnetic Measurements Date: 07-09-2001 Time: 14:21:34 Project: spear3 Magnet Type: gdipole Magnet Name: 145d-010 Serial Number: Run Number: 7 Measurement Device: stretched wire Operator: jy Comment: BL vs. I, mains Standardization: 1 cycles from 0.0 A to 770.0 A to 0.0 A Test Currents (A): 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 500.0 525.0 550.0 575.0 600.0 625.0 650.0 675.0 700.0 650.0 600.0 550.0 500.0 450.0 400.0 14:21:41 Initial Zero Current Measurement, Imag_zero = 0.0000 A 14:21:42 Magnet current ramping to 15.0000 A... 14:22:13 Magnet current ramping to 770.0000 A... 14:26:28 Magnet current ramping to 0.0000 A... 14:31:15 Magnet current ramping to 50.0000 A... 14:31:39 Magnet Current, Imag = 42.8734 A Vtrans = 0.428734 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:40 Magnet Current, Imag = 53.5140 A Vtrans = 0.535140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:41 Magnet Current, Imag = 50.6482 A Vtrans = 0.506482 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:43 Magnet Current, Imag = 48.7046 A Vtrans = 0.487046 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:43 Magnet Current Measurement: Imag = 48.9350 +- 3.8955 A 14:31:43 Magnetic Field Measurement Measuring the magnet strength... 14:31:43 Integrated Voltage Measurement... 14:31:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001337795 Vs 14:32:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001800815 Vs 14:32:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001403103 Vs 14:32:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001800146 Vs 14:32:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001409183 Vs 14:32:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001793321 Vs 14:33:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001401909 Vs 14:33:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001787339 Vs 14:33:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001591702 +- 0.000013227 Vs 14:33:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001591702 +- 0.000013227 Vs BL = 0.15917016 +- 0.00132270 Tm 14:33:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.15917 0.00132 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.15917 0.00132 0.15917 0.00000 14:33:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.15917 0.00132 SL = 0.1591702 +- 0.0013227 Tm^2/m^n 14:33:15 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1591702 +- 0.0013227 Tm^2/m^n 14:33:16 Magnet Current, Imag = 49.9324 A Vtrans = 0.499324 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:18 Magnet Current, Imag = 49.9387 A Vtrans = 0.499387 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:19 Magnet Current, Imag = 49.9151 A Vtrans = 0.499151 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:21 Magnet Current, Imag = 49.9406 A Vtrans = 0.499406 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:21 Magnet Current Measurement: Imag = 49.9317 +- 0.0101 A 14:33:21 Magnet current ramping to 100.0000 A... 14:33:44 Magnet Current, Imag = 99.9713 A Vtrans = 0.999713 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:45 Magnet Current, Imag = 99.9739 A Vtrans = 0.999739 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:47 Magnet Current, Imag = 99.9562 A Vtrans = 0.999562 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:48 Magnet Current, Imag = 99.9604 A Vtrans = 0.999604 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:48 Magnet Current Measurement: Imag = 99.9655 +- 0.0074 A 14:33:49 Magnetic Field Measurement Measuring the magnet strength... 14:33:49 Integrated Voltage Measurement... 14:34:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002988667 Vs 14:34:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003373239 Vs 14:34:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002985326 Vs 14:34:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003373319 Vs 14:34:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002983261 Vs 14:34:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003377647 Vs 14:35:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002992243 Vs 14:35:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003376699 Vs 14:35:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003181300 +- 0.000001924 Vs 14:35:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.003181300 +- 0.000001924 Vs BL = 0.31813002 +- 0.00019237 Tm 14:35:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.31813 0.00019 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.31813 0.00019 0.31813 0.00000 14:35:20 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.31813 0.00019 SL = 0.3181300 +- 0.0001924 Tm^2/m^n 14:35:20 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3181300 +- 0.0001924 Tm^2/m^n 14:35:22 Magnet Current, Imag = 99.9453 A Vtrans = 0.999453 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:23 Magnet Current, Imag = 99.9761 A Vtrans = 0.999761 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:25 Magnet Current, Imag = 99.9721 A Vtrans = 0.999721 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:26 Magnet Current, Imag = 99.9549 A Vtrans = 0.999549 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:26 Magnet Current Measurement: Imag = 99.9621 +- 0.0126 A 14:35:26 Magnet current ramping to 150.0000 A... 14:35:49 Magnet Current, Imag = 149.9976 A Vtrans = 1.499976 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:51 Magnet Current, Imag = 150.0083 A Vtrans = 1.500083 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:52 Magnet Current, Imag = 150.0139 A Vtrans = 1.500139 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:54 Magnet Current, Imag = 150.0110 A Vtrans = 1.500110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:54 Magnet Current Measurement: Imag = 150.0077 +- 0.0062 A 14:35:54 Magnetic Field Measurement Measuring the magnet strength... 14:35:54 Integrated Voltage Measurement... 14:36:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004568751 Vs 14:36:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004961547 Vs 14:36:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004574379 Vs 14:36:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004979947 Vs 14:36:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004578062 Vs 14:37:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004969676 Vs 14:37:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004569938 Vs 14:37:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004968539 Vs 14:37:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004771355 +- 0.000004557 Vs 14:37:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004771355 +- 0.000004557 Vs BL = 0.47713548 +- 0.00045565 Tm 14:37:25 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.47714 0.00046 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.47714 0.00046 0.47714 0.00000 14:37:25 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.47714 0.00046 SL = 0.4771355 +- 0.0004557 Tm^2/m^n 14:37:25 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4771355 +- 0.0004557 Tm^2/m^n 14:37:27 Magnet Current, Imag = 149.9625 A Vtrans = 1.499625 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:28 Magnet Current, Imag = 149.9773 A Vtrans = 1.499773 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:30 Magnet Current, Imag = 149.9649 A Vtrans = 1.499649 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:31 Magnet Current, Imag = 149.9780 A Vtrans = 1.499780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:31 Magnet Current Measurement: Imag = 149.9707 +- 0.0070 A 14:37:32 Magnet current ramping to 200.0000 A... 14:37:55 Magnet Current, Imag = 200.0114 A Vtrans = 2.000114 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:56 Magnet Current, Imag = 199.9945 A Vtrans = 1.999945 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:57 Magnet Current, Imag = 199.9839 A Vtrans = 1.999839 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:59 Magnet Current, Imag = 199.9644 A Vtrans = 1.999644 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:59 Magnet Current Measurement: Imag = 199.9885 +- 0.0170 A 14:37:59 Magnetic Field Measurement Measuring the magnet strength... 14:37:59 Integrated Voltage Measurement... 14:38:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006169523 Vs 14:38:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006546647 Vs 14:38:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006162703 Vs 14:38:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006549045 Vs 14:38:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006176009 Vs 14:39:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006555435 Vs 14:39:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006174437 Vs 14:39:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006559408 Vs 14:39:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006361651 +- 0.000004755 Vs 14:39:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006361651 +- 0.000004755 Vs BL = 0.63616507 +- 0.00047553 Tm 14:39:31 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.63617 0.00048 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.63617 0.00048 0.63617 0.00000 14:39:31 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.63617 0.00048 SL = 0.6361651 +- 0.0004755 Tm^2/m^n 14:39:31 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6361651 +- 0.0004755 Tm^2/m^n 14:39:32 Magnet Current, Imag = 199.9989 A Vtrans = 1.999989 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:34 Magnet Current, Imag = 199.9645 A Vtrans = 1.999645 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:35 Magnet Current, Imag = 199.9611 A Vtrans = 1.999611 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:37 Magnet Current, Imag = 199.9757 A Vtrans = 1.999757 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:37 Magnet Current Measurement: Imag = 199.9750 +- 0.0148 A 14:39:37 Magnet current ramping to 250.0000 A... 14:40:00 Magnet Current, Imag = 249.9993 A Vtrans = 2.499993 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:40:01 Magnet Current, Imag = 250.0060 A Vtrans = 2.500060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:40:03 Magnet Current, Imag = 250.0260 A Vtrans = 2.500260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:40:04 Magnet Current, Imag = 250.0342 A Vtrans = 2.500342 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:40:04 Magnet Current Measurement: Imag = 250.0164 +- 0.0142 A 14:40:04 Magnetic Field Measurement Measuring the magnet strength... 14:40:04 Integrated Voltage Measurement... 14:40:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007755705 Vs 14:40:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008155599 Vs 14:40:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007750849 Vs 14:40:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008144075 Vs 14:41:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007764465 Vs 14:41:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008146983 Vs 14:41:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007746182 Vs 14:41:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008160531 Vs 14:41:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007953049 +- 0.000003363 Vs 14:41:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.007953049 +- 0.000003363 Vs BL = 0.79530487 +- 0.00033633 Tm 14:41:36 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.79530 0.00034 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.79530 0.00034 0.79530 0.00000 14:41:36 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.79530 0.00034 SL = 0.7953049 +- 0.0003363 Tm^2/m^n 14:41:36 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7953049 +- 0.0003363 Tm^2/m^n 14:41:38 Magnet Current, Imag = 250.0248 A Vtrans = 2.500248 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:41:39 Magnet Current, Imag = 250.0088 A Vtrans = 2.500088 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:41:41 Magnet Current, Imag = 249.9860 A Vtrans = 2.499860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:41:42 Magnet Current, Imag = 249.9788 A Vtrans = 2.499788 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:41:42 Magnet Current Measurement: Imag = 249.9996 +- 0.0183 A 14:41:43 Magnet current ramping to 300.0000 A... 14:42:05 Magnet Current, Imag = 300.0542 A Vtrans = 3.000542 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:42:07 Magnet Current, Imag = 300.0530 A Vtrans = 3.000530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:42:08 Magnet Current, Imag = 300.0383 A Vtrans = 3.000383 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:42:10 Magnet Current, Imag = 300.0352 A Vtrans = 3.000352 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:42:10 Magnet Current Measurement: Imag = 300.0452 +- 0.0085 A 14:42:10 Magnetic Field Measurement Measuring the magnet strength... 14:42:10 Integrated Voltage Measurement... 14:42:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009337707 Vs 14:42:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009740600 Vs 14:42:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009350901 Vs 14:42:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009739759 Vs 14:43:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009343327 Vs 14:43:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009755081 Vs 14:43:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009352302 Vs 14:43:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009739737 Vs 14:43:38 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009544927 +- 0.000003639 Vs 14:43:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009544927 +- 0.000003639 Vs BL = 0.95449268 +- 0.00036395 Tm 14:43:42 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.95449 0.00036 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.95449 0.00036 0.95449 0.00000 14:43:42 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.95449 0.00036 SL = 0.9544927 +- 0.0003639 Tm^2/m^n 14:43:42 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9544927 +- 0.0003639 Tm^2/m^n 14:43:43 Magnet Current, Imag = 300.0572 A Vtrans = 3.000572 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:45 Magnet Current, Imag = 300.0519 A Vtrans = 3.000519 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:46 Magnet Current, Imag = 300.0531 A Vtrans = 3.000531 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:48 Magnet Current, Imag = 300.0327 A Vtrans = 3.000327 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:48 Magnet Current Measurement: Imag = 300.0487 +- 0.0095 A 14:43:48 Magnet current ramping to 350.0000 A... 14:44:11 Magnet Current, Imag = 350.0880 A Vtrans = 3.500880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:44:13 Magnet Current, Imag = 350.1040 A Vtrans = 3.501040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:44:15 Magnet Current, Imag = 350.0690 A Vtrans = 3.500690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:44:17 Magnet Current, Imag = 350.0720 A Vtrans = 3.500720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:44:17 Magnet Current Measurement: Imag = 350.0833 +- 0.0140 A 14:44:17 Magnetic Field Measurement Measuring the magnet strength... 14:44:18 Integrated Voltage Measurement... 14:44:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010954718 Vs 14:44:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011324101 Vs 14:44:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010942615 Vs 14:45:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011327371 Vs 14:45:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010941335 Vs 14:45:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011318349 Vs 14:45:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010940775 Vs 14:45:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011336985 Vs 14:45:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011135781 +- 0.000003830 Vs 14:45:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.011135781 +- 0.000003830 Vs BL = 1.11357812 +- 0.00038296 Tm 14:45:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.11358 0.00038 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.11358 0.00038 1.11358 0.00000 14:45:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.11358 0.00038 SL = 1.1135781 +- 0.0003830 Tm^2/m^n 14:45:49 Magnet Strength Measurement Harmonic Number = 1 SL = 1.1135781 +- 0.0003830 Tm^2/m^n 14:45:51 Magnet Current, Imag = 350.0590 A Vtrans = 3.500590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:53 Magnet Current, Imag = 350.0870 A Vtrans = 3.500870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:55 Magnet Current, Imag = 350.0960 A Vtrans = 3.500960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:57 Magnet Current, Imag = 350.1160 A Vtrans = 3.501160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:57 Magnet Current Measurement: Imag = 350.0895 +- 0.0205 A 14:45:57 Magnet current ramping to 400.0000 A... 14:46:21 Magnet Current, Imag = 400.0820 A Vtrans = 4.000820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:46:22 Magnet Current, Imag = 400.0840 A Vtrans = 4.000840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:46:24 Magnet Current, Imag = 400.0690 A Vtrans = 4.000690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:46:25 Magnet Current, Imag = 400.0870 A Vtrans = 4.000870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:46:25 Magnet Current Measurement: Imag = 400.0805 +- 0.0069 A 14:46:26 Magnetic Field Measurement Measuring the magnet strength... 14:46:26 Integrated Voltage Measurement... 14:46:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012520856 Vs 14:46:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012932276 Vs 14:47:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012535112 Vs 14:47:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012934799 Vs 14:47:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012545835 Vs 14:47:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012946258 Vs 14:47:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012529305 Vs 14:47:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012919705 Vs 14:47:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012733018 +- 0.000008479 Vs 14:47:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012733018 +- 0.000008479 Vs BL = 1.27330182 +- 0.00084794 Tm 14:47:57 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.27330 0.00085 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.27330 0.00085 1.27330 0.00000 14:47:57 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.27330 0.00085 SL = 1.2733018 +- 0.0008479 Tm^2/m^n 14:47:57 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2733018 +- 0.0008479 Tm^2/m^n 14:47:59 Magnet Current, Imag = 400.0880 A Vtrans = 4.000880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:48:01 Magnet Current, Imag = 400.0700 A Vtrans = 4.000700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:48:02 Magnet Current, Imag = 400.0500 A Vtrans = 4.000500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:48:04 Magnet Current, Imag = 400.0480 A Vtrans = 4.000480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:48:04 Magnet Current Measurement: Imag = 400.0640 +- 0.0163 A 14:48:04 Magnet current ramping to 450.0000 A... 14:48:27 Magnet Current, Imag = 450.0930 A Vtrans = 4.500930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:48:29 Magnet Current, Imag = 450.0980 A Vtrans = 4.500980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:48:30 Magnet Current, Imag = 450.1040 A Vtrans = 4.501040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:48:32 Magnet Current, Imag = 450.1150 A Vtrans = 4.501150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:48:32 Magnet Current Measurement: Imag = 450.1025 +- 0.0082 A 14:48:32 Magnetic Field Measurement Measuring the magnet strength... 14:48:32 Integrated Voltage Measurement... 14:48:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014128535 Vs 14:48:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014515071 Vs 14:49:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014129585 Vs 14:49:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014532536 Vs 14:49:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014139701 Vs 14:49:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014517365 Vs 14:49:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014112959 Vs 14:50:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014533658 Vs 14:50:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014326176 +- 0.000003767 Vs 14:50:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014326176 +- 0.000003767 Vs BL = 1.43261763 +- 0.00037670 Tm 14:50:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43262 0.00038 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.43262 0.00038 1.43262 0.00000 14:50:04 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43262 0.00038 SL = 1.4326176 +- 0.0003767 Tm^2/m^n 14:50:04 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4326176 +- 0.0003767 Tm^2/m^n 14:50:05 Magnet Current, Imag = 450.1150 A Vtrans = 4.501150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:50:07 Magnet Current, Imag = 450.1280 A Vtrans = 4.501280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:50:09 Magnet Current, Imag = 450.1270 A Vtrans = 4.501270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:50:10 Magnet Current, Imag = 450.1360 A Vtrans = 4.501360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:50:10 Magnet Current Measurement: Imag = 450.1265 +- 0.0075 A 14:50:11 Magnet current ramping to 500.0000 A... 14:50:34 Magnet Current, Imag = 500.1050 A Vtrans = 5.001050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:50:35 Magnet Current, Imag = 500.1210 A Vtrans = 5.001210 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:50:37 Magnet Current, Imag = 500.1300 A Vtrans = 5.001300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:50:38 Magnet Current, Imag = 500.1490 A Vtrans = 5.001490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:50:38 Magnet Current Measurement: Imag = 500.1262 +- 0.0159 A 14:50:39 Magnetic Field Measurement Measuring the magnet strength... 14:50:39 Integrated Voltage Measurement... 14:50:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015714606 Vs 14:51:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016095890 Vs 14:51:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015715642 Vs 14:51:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016087011 Vs 14:51:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015716044 Vs 14:51:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016108723 Vs 14:51:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015719401 Vs 14:52:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016095109 Vs 14:52:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015906553 +- 0.000003985 Vs 14:52:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015906553 +- 0.000003985 Vs BL = 1.59065532 +- 0.00039846 Tm 14:52:10 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.59066 0.00040 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.59066 0.00040 1.59066 0.00000 14:52:10 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.59066 0.00040 SL = 1.5906553 +- 0.0003985 Tm^2/m^n 14:52:11 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5906553 +- 0.0003985 Tm^2/m^n 14:52:12 Magnet Current, Imag = 500.1550 A Vtrans = 5.001550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:52:14 Magnet Current, Imag = 500.1690 A Vtrans = 5.001690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:52:15 Magnet Current, Imag = 500.1620 A Vtrans = 5.001620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:52:17 Magnet Current, Imag = 500.1630 A Vtrans = 5.001630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:52:17 Magnet Current Measurement: Imag = 500.1622 +- 0.0050 A 14:52:17 Magnet current ramping to 525.0000 A... 14:52:33 Magnet Current, Imag = 525.1320 A Vtrans = 5.251320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:52:35 Magnet Current, Imag = 525.1590 A Vtrans = 5.251590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:52:36 Magnet Current, Imag = 525.1560 A Vtrans = 5.251560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:52:38 Magnet Current, Imag = 525.1560 A Vtrans = 5.251560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:52:38 Magnet Current Measurement: Imag = 525.1508 +- 0.0109 A 14:52:38 Magnetic Field Measurement Measuring the magnet strength... 14:52:38 Integrated Voltage Measurement... 14:52:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016488289 Vs 14:53:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016880317 Vs 14:53:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016506215 Vs 14:53:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016894295 Vs 14:53:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016508918 Vs 14:53:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016901165 Vs 14:53:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016493178 Vs 14:54:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016888125 Vs 14:54:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016695063 +- 0.000008090 Vs 14:54:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016695063 +- 0.000008090 Vs BL = 1.66950627 +- 0.00080898 Tm 14:54:10 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.66951 0.00081 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.66951 0.00081 1.66951 0.00000 14:54:10 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.66951 0.00081 SL = 1.6695063 +- 0.0008090 Tm^2/m^n 14:54:10 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6695063 +- 0.0008090 Tm^2/m^n 14:54:12 Magnet Current, Imag = 525.1700 A Vtrans = 5.251700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:54:13 Magnet Current, Imag = 525.1830 A Vtrans = 5.251830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:54:15 Magnet Current, Imag = 525.1840 A Vtrans = 5.251840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:54:16 Magnet Current, Imag = 525.1820 A Vtrans = 5.251820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:54:16 Magnet Current Measurement: Imag = 525.1798 +- 0.0057 A 14:54:17 Magnet current ramping to 550.0000 A... 14:54:32 Magnet Current, Imag = 550.1470 A Vtrans = 5.501470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:54:34 Magnet Current, Imag = 550.1550 A Vtrans = 5.501550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:54:36 Magnet Current, Imag = 550.1550 A Vtrans = 5.501550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:54:37 Magnet Current, Imag = 550.1530 A Vtrans = 5.501530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:54:37 Magnet Current Measurement: Imag = 550.1525 +- 0.0033 A 14:54:37 Magnetic Field Measurement Measuring the magnet strength... 14:54:37 Integrated Voltage Measurement... 14:54:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017286032 Vs 14:55:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017664841 Vs 14:55:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017265261 Vs 14:55:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017667709 Vs 14:55:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017271125 Vs 14:55:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017663162 Vs 14:55:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017279836 Vs 14:56:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017656952 Vs 14:56:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017469365 +- 0.000003572 Vs 14:56:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017469365 +- 0.000003572 Vs BL = 1.74693648 +- 0.00035719 Tm 14:56:09 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.74694 0.00036 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.74694 0.00036 1.74694 0.00000 14:56:09 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.74694 0.00036 SL = 1.7469365 +- 0.0003572 Tm^2/m^n 14:56:10 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7469365 +- 0.0003572 Tm^2/m^n 14:56:11 Magnet Current, Imag = 550.1710 A Vtrans = 5.501710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:56:13 Magnet Current, Imag = 550.1480 A Vtrans = 5.501480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:56:14 Magnet Current, Imag = 550.1410 A Vtrans = 5.501410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:56:16 Magnet Current, Imag = 550.1170 A Vtrans = 5.501170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:56:16 Magnet Current Measurement: Imag = 550.1443 +- 0.0193 A 14:56:16 Magnet current ramping to 575.0000 A... 14:56:32 Magnet Current, Imag = 575.1470 A Vtrans = 5.751470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:56:34 Magnet Current, Imag = 575.1660 A Vtrans = 5.751660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:56:35 Magnet Current, Imag = 575.1650 A Vtrans = 5.751650 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:56:37 Magnet Current, Imag = 575.1570 A Vtrans = 5.751570 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:56:37 Magnet Current Measurement: Imag = 575.1587 +- 0.0076 A 14:56:37 Magnetic Field Measurement Measuring the magnet strength... 14:56:37 Integrated Voltage Measurement... 14:56:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018049995 Vs 14:57:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018437055 Vs 14:57:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018057951 Vs 14:57:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018443432 Vs 14:57:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018057607 Vs 14:57:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018449530 Vs 14:57:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018039668 Vs 14:58:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018439801 Vs 14:58:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018246880 +- 0.000005513 Vs 14:58:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.018246880 +- 0.000005513 Vs BL = 1.82468800 +- 0.00055130 Tm 14:58:09 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.82469 0.00055 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.82469 0.00055 1.82469 0.00000 14:58:09 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.82469 0.00055 SL = 1.8246880 +- 0.0005513 Tm^2/m^n 14:58:09 Magnet Strength Measurement Harmonic Number = 1 SL = 1.8246880 +- 0.0005513 Tm^2/m^n 14:58:11 Magnet Current, Imag = 575.1860 A Vtrans = 5.751860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:58:12 Magnet Current, Imag = 575.1800 A Vtrans = 5.751800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:58:14 Magnet Current, Imag = 575.1690 A Vtrans = 5.751690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:58:15 Magnet Current, Imag = 575.1580 A Vtrans = 5.751580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:58:15 Magnet Current Measurement: Imag = 575.1732 +- 0.0107 A 14:58:16 Magnet current ramping to 600.0000 A... 14:58:31 Magnet Current, Imag = 600.2170 A Vtrans = 6.002170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:58:33 Magnet Current, Imag = 600.2180 A Vtrans = 6.002180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:58:35 Magnet Current, Imag = 600.1910 A Vtrans = 6.001910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:58:36 Magnet Current, Imag = 600.1730 A Vtrans = 6.001730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:58:36 Magnet Current Measurement: Imag = 600.1997 +- 0.0189 A 14:58:36 Magnetic Field Measurement Measuring the magnet strength... 14:58:36 Integrated Voltage Measurement... 14:58:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018815791 Vs 14:59:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019191130 Vs 14:59:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018810117 Vs 14:59:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019199777 Vs 14:59:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018816567 Vs 14:59:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019191717 Vs 14:59:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018822580 Vs 15:00:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019205201 Vs 15:00:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019006610 +- 0.000004236 Vs 15:00:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019006610 +- 0.000004236 Vs BL = 1.90066100 +- 0.00042363 Tm 15:00:08 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.90066 0.00042 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.90066 0.00042 1.90066 0.00000 15:00:08 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.90066 0.00042 SL = 1.9006610 +- 0.0004236 Tm^2/m^n 15:00:09 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9006610 +- 0.0004236 Tm^2/m^n 15:00:10 Magnet Current, Imag = 600.2000 A Vtrans = 6.002000 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:00:12 Magnet Current, Imag = 600.1900 A Vtrans = 6.001900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:00:13 Magnet Current, Imag = 600.1710 A Vtrans = 6.001710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:00:15 Magnet Current, Imag = 600.1850 A Vtrans = 6.001850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:00:15 Magnet Current Measurement: Imag = 600.1865 +- 0.0105 A 15:00:15 Magnet current ramping to 625.0000 A... 15:00:31 Magnet Current, Imag = 625.2340 A Vtrans = 6.252340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:00:32 Magnet Current, Imag = 625.2320 A Vtrans = 6.252320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:00:34 Magnet Current, Imag = 625.2230 A Vtrans = 6.252230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:00:36 Magnet Current, Imag = 625.2320 A Vtrans = 6.252320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:00:36 Magnet Current Measurement: Imag = 625.2302 +- 0.0043 A 15:00:36 Magnetic Field Measurement Measuring the magnet strength... 15:00:36 Integrated Voltage Measurement... 15:00:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019556513 Vs 15:01:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019944343 Vs 15:01:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019552019 Vs 15:01:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019937977 Vs 15:01:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019544379 Vs 15:01:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019940885 Vs 15:01:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019562716 Vs 15:02:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019940517 Vs 15:02:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019747419 +- 0.000003723 Vs 15:02:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019747419 +- 0.000003723 Vs BL = 1.97474186 +- 0.00037232 Tm 15:02:08 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.97474 0.00037 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.97474 0.00037 1.97474 0.00000 15:02:08 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.97474 0.00037 SL = 1.9747419 +- 0.0003723 Tm^2/m^n 15:02:08 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9747419 +- 0.0003723 Tm^2/m^n 15:02:10 Magnet Current, Imag = 625.1790 A Vtrans = 6.251790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:02:11 Magnet Current, Imag = 625.1960 A Vtrans = 6.251960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:02:13 Magnet Current, Imag = 625.1950 A Vtrans = 6.251950 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:02:14 Magnet Current, Imag = 625.1980 A Vtrans = 6.251980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:02:15 Magnet Current Measurement: Imag = 625.1920 +- 0.0076 A 15:02:15 Magnet current ramping to 650.0000 A... 15:02:30 Magnet Current, Imag = 650.2260 A Vtrans = 6.502260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:02:32 Magnet Current, Imag = 650.2280 A Vtrans = 6.502280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:02:34 Magnet Current, Imag = 650.2530 A Vtrans = 6.502530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:02:35 Magnet Current, Imag = 650.2460 A Vtrans = 6.502460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:02:35 Magnet Current Measurement: Imag = 650.2382 +- 0.0115 A 15:02:35 Magnetic Field Measurement Measuring the magnet strength... 15:02:35 Integrated Voltage Measurement... 15:02:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020261045 Vs 15:02:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020649780 Vs 15:03:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020254952 Vs 15:03:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020647269 Vs 15:03:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020251856 Vs 15:03:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020655061 Vs 15:03:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020257431 Vs 15:04:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020647781 Vs 15:04:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020453147 +- 0.000001555 Vs 15:04:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020453147 +- 0.000001555 Vs BL = 2.04531468 +- 0.00015549 Tm 15:04:07 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.04531 0.00016 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.04531 0.00016 2.04531 0.00000 15:04:07 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.04531 0.00016 SL = 2.0453147 +- 0.0001555 Tm^2/m^n 15:04:07 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0453147 +- 0.0001555 Tm^2/m^n 15:04:09 Magnet Current, Imag = 650.2190 A Vtrans = 6.502190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:04:11 Magnet Current, Imag = 650.2320 A Vtrans = 6.502320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:04:12 Magnet Current, Imag = 650.2220 A Vtrans = 6.502220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:04:14 Magnet Current, Imag = 650.2300 A Vtrans = 6.502300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:04:14 Magnet Current Measurement: Imag = 650.2258 +- 0.0054 A 15:04:14 Magnet current ramping to 675.0000 A... 15:04:30 Magnet Current, Imag = 675.2050 A Vtrans = 6.752050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:04:31 Magnet Current, Imag = 675.2150 A Vtrans = 6.752150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:04:33 Magnet Current, Imag = 675.2280 A Vtrans = 6.752280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:04:34 Magnet Current, Imag = 675.2640 A Vtrans = 6.752640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:04:34 Magnet Current Measurement: Imag = 675.2280 +- 0.0223 A 15:04:35 Magnetic Field Measurement Measuring the magnet strength... 15:04:35 Integrated Voltage Measurement... 15:04:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020921412 Vs 15:04:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021312175 Vs 15:05:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020923153 Vs 15:05:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021321353 Vs 15:05:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020915786 Vs 15:05:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021314329 Vs 15:05:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020921398 Vs 15:06:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021315611 Vs 15:06:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021118152 +- 0.000002663 Vs 15:06:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021118152 +- 0.000002663 Vs BL = 2.11181521 +- 0.00026629 Tm 15:06:07 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.11182 0.00027 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.11182 0.00027 2.11182 0.00000 15:06:07 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.11182 0.00027 SL = 2.1118152 +- 0.0002663 Tm^2/m^n 15:06:07 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1118152 +- 0.0002663 Tm^2/m^n 15:06:08 Magnet Current, Imag = 675.2160 A Vtrans = 6.752160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:06:10 Magnet Current, Imag = 675.2340 A Vtrans = 6.752340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:06:12 Magnet Current, Imag = 675.2440 A Vtrans = 6.752440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:06:13 Magnet Current, Imag = 675.2240 A Vtrans = 6.752240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:06:13 Magnet Current Measurement: Imag = 675.2295 +- 0.0105 A 15:06:13 Magnet current ramping to 700.0000 A... 15:06:29 Magnet Current, Imag = 700.2480 A Vtrans = 7.002480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:06:31 Magnet Current, Imag = 700.2220 A Vtrans = 7.002220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:06:32 Magnet Current, Imag = 700.2110 A Vtrans = 7.002110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:06:34 Magnet Current, Imag = 700.2440 A Vtrans = 7.002440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:06:34 Magnet Current Measurement: Imag = 700.2312 +- 0.0153 A 15:06:34 Magnetic Field Measurement Measuring the magnet strength... 15:06:34 Integrated Voltage Measurement... 15:06:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021529339 Vs 15:06:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021935463 Vs 15:07:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021534839 Vs 15:07:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021938077 Vs 15:07:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021545361 Vs 15:07:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021924371 Vs 15:07:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021531463 Vs 15:08:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021933709 Vs 15:08:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021734078 +- 0.000001682 Vs 15:08:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021734078 +- 0.000001682 Vs BL = 2.17340778 +- 0.00016825 Tm 15:08:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.17341 0.00017 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.17341 0.00017 2.17341 0.00000 15:08:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.17341 0.00017 SL = 2.1734078 +- 0.0001682 Tm^2/m^n 15:08:06 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1734078 +- 0.0001682 Tm^2/m^n 15:08:08 Magnet Current, Imag = 700.2660 A Vtrans = 7.002660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:08:09 Magnet Current, Imag = 700.2640 A Vtrans = 7.002640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:08:11 Magnet Current, Imag = 700.2540 A Vtrans = 7.002540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:08:12 Magnet Current, Imag = 700.2700 A Vtrans = 7.002700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:08:12 Magnet Current Measurement: Imag = 700.2635 +- 0.0059 A 15:08:13 Magnet current ramping to 650.0000 A... 15:08:36 Magnet Current, Imag = 650.2460 A Vtrans = 6.502460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:08:37 Magnet Current, Imag = 650.2510 A Vtrans = 6.502510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:08:39 Magnet Current, Imag = 650.2340 A Vtrans = 6.502340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:08:40 Magnet Current, Imag = 650.2540 A Vtrans = 6.502540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:08:40 Magnet Current Measurement: Imag = 650.2462 +- 0.0076 A 15:08:40 Magnetic Field Measurement Measuring the magnet strength... 15:08:41 Integrated Voltage Measurement... 15:08:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020329517 Vs 15:09:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020723213 Vs 15:09:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020345365 Vs 15:09:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020723768 Vs 15:09:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020336278 Vs 15:09:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020715704 Vs 15:09:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020337805 Vs 15:10:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020728855 Vs 15:10:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020530063 +- 0.000003912 Vs 15:10:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020530063 +- 0.000003912 Vs BL = 2.05300630 +- 0.00039119 Tm 15:10:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.05301 0.00039 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.05301 0.00039 2.05301 0.00000 15:10:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.05301 0.00039 SL = 2.0530063 +- 0.0003912 Tm^2/m^n 15:10:12 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0530063 +- 0.0003912 Tm^2/m^n 15:10:14 Magnet Current, Imag = 650.2290 A Vtrans = 6.502290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:10:16 Magnet Current, Imag = 650.2000 A Vtrans = 6.502000 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:10:17 Magnet Current, Imag = 650.2060 A Vtrans = 6.502060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:10:19 Magnet Current, Imag = 650.2450 A Vtrans = 6.502450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:10:19 Magnet Current Measurement: Imag = 650.2200 +- 0.0180 A 15:10:19 Magnet current ramping to 600.0000 A... 15:10:42 Magnet Current, Imag = 600.1820 A Vtrans = 6.001820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:10:44 Magnet Current, Imag = 600.1870 A Vtrans = 6.001870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:10:45 Magnet Current, Imag = 600.1700 A Vtrans = 6.001700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:10:47 Magnet Current, Imag = 600.1690 A Vtrans = 6.001690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:10:47 Magnet Current Measurement: Imag = 600.1770 +- 0.0077 A 15:10:47 Magnetic Field Measurement Measuring the magnet strength... 15:10:47 Integrated Voltage Measurement... 15:11:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018889439 Vs 15:11:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019284065 Vs 15:11:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018881607 Vs 15:11:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019280993 Vs 15:11:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018892907 Vs 15:11:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019279392 Vs 15:12:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018898763 Vs 15:12:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019283243 Vs 15:12:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019086301 +- 0.000003440 Vs 15:12:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019086301 +- 0.000003440 Vs BL = 1.90863011 +- 0.00034403 Tm 15:12:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.90863 0.00034 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.90863 0.00034 1.90863 0.00000 15:12:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.90863 0.00034 SL = 1.9086301 +- 0.0003440 Tm^2/m^n 15:12:19 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9086301 +- 0.0003440 Tm^2/m^n 15:12:21 Magnet Current, Imag = 600.1770 A Vtrans = 6.001770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:12:22 Magnet Current, Imag = 600.1630 A Vtrans = 6.001630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:12:24 Magnet Current, Imag = 600.1740 A Vtrans = 6.001740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:12:25 Magnet Current, Imag = 600.1940 A Vtrans = 6.001940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:12:26 Magnet Current Measurement: Imag = 600.1770 +- 0.0111 A 15:12:26 Magnet current ramping to 550.0000 A... 15:12:49 Magnet Current, Imag = 550.1260 A Vtrans = 5.501260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:12:50 Magnet Current, Imag = 550.1330 A Vtrans = 5.501330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:12:52 Magnet Current, Imag = 550.1450 A Vtrans = 5.501450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:12:54 Magnet Current, Imag = 550.1360 A Vtrans = 5.501360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:12:54 Magnet Current Measurement: Imag = 550.1350 +- 0.0068 A 15:12:54 Magnetic Field Measurement Measuring the magnet strength... 15:12:54 Integrated Voltage Measurement... 15:13:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017352707 Vs 15:13:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017744128 Vs 15:13:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017357399 Vs 15:13:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017754989 Vs 15:13:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017326257 Vs 15:14:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017737135 Vs 15:14:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017344872 Vs 15:14:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017750029 Vs 15:14:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017545940 +- 0.000008895 Vs 15:14:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017545940 +- 0.000008895 Vs BL = 1.75459397 +- 0.00088946 Tm 15:14:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.75459 0.00089 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.75459 0.00089 1.75459 0.00000 15:14:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.75459 0.00089 SL = 1.7545940 +- 0.0008895 Tm^2/m^n 15:14:26 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7545940 +- 0.0008895 Tm^2/m^n 15:14:27 Magnet Current, Imag = 550.1660 A Vtrans = 5.501660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:14:29 Magnet Current, Imag = 550.1650 A Vtrans = 5.501650 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:14:30 Magnet Current, Imag = 550.1610 A Vtrans = 5.501610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:14:32 Magnet Current, Imag = 550.1410 A Vtrans = 5.501410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:14:32 Magnet Current Measurement: Imag = 550.1582 +- 0.0101 A 15:14:32 Magnet current ramping to 500.0000 A... 15:14:55 Magnet Current, Imag = 500.1830 A Vtrans = 5.001830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:14:57 Magnet Current, Imag = 500.1580 A Vtrans = 5.001580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:14:59 Magnet Current, Imag = 500.1500 A Vtrans = 5.001500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:15:00 Magnet Current, Imag = 500.1770 A Vtrans = 5.001770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:15:00 Magnet Current Measurement: Imag = 500.1670 +- 0.0135 A 15:15:00 Magnetic Field Measurement Measuring the magnet strength... 15:15:01 Integrated Voltage Measurement... 15:15:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015775435 Vs 15:15:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016163390 Vs 15:15:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015763283 Vs 15:15:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016166295 Vs 15:15:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015761985 Vs 15:16:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016163840 Vs 15:16:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015788342 Vs 15:16:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016182998 Vs 15:16:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015970696 +- 0.000008963 Vs 15:16:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015970696 +- 0.000008963 Vs BL = 1.59706960 +- 0.00089631 Tm 15:16:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.59707 0.00090 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.59707 0.00090 1.59707 0.00000 15:16:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.59707 0.00090 SL = 1.5970696 +- 0.0008963 Tm^2/m^n 15:16:32 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5970696 +- 0.0008963 Tm^2/m^n 15:16:34 Magnet Current, Imag = 500.1520 A Vtrans = 5.001520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:16:35 Magnet Current, Imag = 500.1460 A Vtrans = 5.001460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:16:37 Magnet Current, Imag = 500.1420 A Vtrans = 5.001420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:16:39 Magnet Current, Imag = 500.1660 A Vtrans = 5.001660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:16:39 Magnet Current Measurement: Imag = 500.1515 +- 0.0091 A 15:16:39 Magnet current ramping to 450.0000 A... 15:17:02 Magnet Current, Imag = 450.1130 A Vtrans = 4.501130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:17:03 Magnet Current, Imag = 450.1180 A Vtrans = 4.501180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:17:05 Magnet Current, Imag = 450.1110 A Vtrans = 4.501110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:17:07 Magnet Current, Imag = 450.1110 A Vtrans = 4.501110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:17:07 Magnet Current Measurement: Imag = 450.1132 +- 0.0029 A 15:17:07 Magnetic Field Measurement Measuring the magnet strength... 15:17:07 Integrated Voltage Measurement... 15:17:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014179303 Vs 15:17:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014587053 Vs 15:17:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014183609 Vs 15:17:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014580885 Vs 15:18:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014191733 Vs 15:18:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014576862 Vs 15:18:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014170726 Vs 15:18:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014575613 Vs 15:18:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014380723 +- 0.000004421 Vs 15:18:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014380723 +- 0.000004421 Vs BL = 1.43807231 +- 0.00044210 Tm 15:18:39 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43807 0.00044 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.43807 0.00044 1.43807 0.00000 15:18:39 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43807 0.00044 SL = 1.4380723 +- 0.0004421 Tm^2/m^n 15:18:39 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4380723 +- 0.0004421 Tm^2/m^n 15:18:40 Magnet Current, Imag = 450.0930 A Vtrans = 4.500930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:18:42 Magnet Current, Imag = 450.0970 A Vtrans = 4.500970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:18:44 Magnet Current, Imag = 450.1150 A Vtrans = 4.501150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:18:45 Magnet Current, Imag = 450.1230 A Vtrans = 4.501230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:18:45 Magnet Current Measurement: Imag = 450.1070 +- 0.0124 A 15:18:45 Magnet current ramping to 400.0000 A... 15:19:08 Magnet Current, Imag = 400.0560 A Vtrans = 4.000560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:19:10 Magnet Current, Imag = 400.0530 A Vtrans = 4.000530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:19:12 Magnet Current, Imag = 400.0420 A Vtrans = 4.000420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:19:13 Magnet Current, Imag = 400.0620 A Vtrans = 4.000620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:19:13 Magnet Current Measurement: Imag = 400.0532 +- 0.0073 A 15:19:13 Magnetic Field Measurement Measuring the magnet strength... 15:19:14 Integrated Voltage Measurement... 15:19:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012600781 Vs 15:19:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012982811 Vs 15:19:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012596843 Vs 15:19:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012978363 Vs 15:20:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012595835 Vs 15:20:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012975633 Vs 15:20:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012606488 Vs