SLAC Magnetic Measurements Date: 01-17-2002 Time: 13:55:23 Project: spear3 Magnet Type: gdipole Magnet Name: 145d-009a Serial Number: Run Number: 8 Measurement Device: stretched wire Operator: jy Comment: bl v.i Standardization: 1 cycles from 0.0 A to 770.0 A to 0.0 A Test Currents (A): 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 500.0 525.0 550.0 575.0 600.0 625.0 650.0 675.0 700.0 650.0 600.0 550.0 500.0 450.0 400.0 13:55:30 Initial Zero Current Measurement, Imag_zero = 0.0000 A 13:55:30 Magnet current ramping to 15.0000 A... 13:56:01 Magnet current ramping to 770.0000 A... 14:00:23 Magnet current ramping to 0.0000 A... 14:05:17 Magnet current ramping to 50.0000 A... 14:05:41 Magnet Current, Imag = 54.8242 A Vtrans = 0.548242 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:05:42 Magnet Current, Imag = 41.9702 A Vtrans = 0.419702 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:05:44 Magnet Current, Imag = 52.1594 A Vtrans = 0.521594 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:05:45 Magnet Current, Imag = 50.4376 A Vtrans = 0.504376 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:05:45 Magnet Current Measurement: Imag = 49.8479 +- 4.8092 A 14:05:45 Magnetic Field Measurement Measuring the magnet strength... 14:05:45 Integrated Voltage Measurement... 14:05:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001335769 Vs 14:06:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001784475 Vs 14:06:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001398511 Vs 14:06:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001786680 Vs 14:06:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001389229 Vs 14:06:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001788366 Vs 14:07:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001402507 Vs 14:07:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001781887 Vs 14:07:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001583428 +- 0.000013537 Vs 14:07:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001583428 +- 0.000013537 Vs BL = 0.15834278 +- 0.00135365 Tm 14:07:16 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.15834 0.00135 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.15834 0.00135 0.15834 0.00000 14:07:16 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.15834 0.00135 SL = 0.1583428 +- 0.0013537 Tm^2/m^n 14:07:16 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1583428 +- 0.0013537 Tm^2/m^n 14:07:17 Magnet Current, Imag = 49.5411 A Vtrans = 0.495411 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:07:19 Magnet Current, Imag = 49.5772 A Vtrans = 0.495772 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:07:20 Magnet Current, Imag = 49.5590 A Vtrans = 0.495590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:07:22 Magnet Current, Imag = 49.5576 A Vtrans = 0.495576 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:07:22 Magnet Current Measurement: Imag = 49.5587 +- 0.0128 A 14:07:22 Magnet current ramping to 100.0000 A... 14:07:45 Magnet Current, Imag = 99.6287 A Vtrans = 0.996287 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:07:46 Magnet Current, Imag = 99.6179 A Vtrans = 0.996179 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:07:47 Magnet Current, Imag = 99.6188 A Vtrans = 0.996188 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:07:49 Magnet Current, Imag = 99.6225 A Vtrans = 0.996225 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:07:49 Magnet Current Measurement: Imag = 99.6220 +- 0.0042 A 14:07:49 Magnetic Field Measurement Measuring the magnet strength... 14:07:49 Integrated Voltage Measurement... 14:08:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002961622 Vs 14:08:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003368379 Vs 14:08:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002965626 Vs 14:08:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003361899 Vs 14:08:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002967849 Vs 14:08:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003370213 Vs 14:09:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002984477 Vs 14:09:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003360863 Vs 14:09:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003167616 +- 0.000003508 Vs 14:09:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.003167616 +- 0.000003508 Vs BL = 0.31676160 +- 0.00035083 Tm 14:09:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.31676 0.00035 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.31676 0.00035 0.31676 0.00000 14:09:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.31676 0.00035 SL = 0.3167616 +- 0.0003508 Tm^2/m^n 14:09:19 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3167616 +- 0.0003508 Tm^2/m^n 14:09:21 Magnet Current, Imag = 99.6221 A Vtrans = 0.996221 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:09:22 Magnet Current, Imag = 99.6004 A Vtrans = 0.996004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:09:24 Magnet Current, Imag = 99.6584 A Vtrans = 0.996584 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:09:25 Magnet Current, Imag = 99.6173 A Vtrans = 0.996173 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:09:25 Magnet Current Measurement: Imag = 99.6245 +- 0.0211 A 14:09:25 Magnet current ramping to 150.0000 A... 14:09:50 Magnet Current, Imag = 149.6790 A Vtrans = 1.496790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:09:51 Magnet Current, Imag = 149.6084 A Vtrans = 1.496084 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:09:52 Magnet Current, Imag = 149.6700 A Vtrans = 1.496700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:09:54 Magnet Current, Imag = 149.7172 A Vtrans = 1.497172 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:09:54 Magnet Current Measurement: Imag = 149.6686 +- 0.0390 A 14:09:54 Magnetic Field Measurement Measuring the magnet strength... 14:09:54 Integrated Voltage Measurement... 14:10:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004548100 Vs 14:10:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004949370 Vs 14:10:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004570871 Vs 14:10:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004947937 Vs 14:10:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004553117 Vs 14:11:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004960075 Vs 14:11:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004586459 Vs 14:11:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004951155 Vs 14:11:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004758386 +- 0.000007176 Vs 14:11:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004758386 +- 0.000007176 Vs BL = 0.47583855 +- 0.00071761 Tm 14:11:24 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.47584 0.00072 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.47584 0.00072 0.47584 0.00000 14:11:24 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.47584 0.00072 SL = 0.4758386 +- 0.0007176 Tm^2/m^n 14:11:24 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4758386 +- 0.0007176 Tm^2/m^n 14:11:26 Magnet Current, Imag = 149.6677 A Vtrans = 1.496677 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:27 Magnet Current, Imag = 149.6385 A Vtrans = 1.496385 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:28 Magnet Current, Imag = 149.6937 A Vtrans = 1.496937 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:30 Magnet Current, Imag = 149.7076 A Vtrans = 1.497076 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:30 Magnet Current Measurement: Imag = 149.6769 +- 0.0264 A 14:11:30 Magnet current ramping to 200.0000 A... 14:11:53 Magnet Current, Imag = 199.6795 A Vtrans = 1.996795 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:55 Magnet Current, Imag = 199.6992 A Vtrans = 1.996992 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:56 Magnet Current, Imag = 199.6939 A Vtrans = 1.996939 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:57 Magnet Current, Imag = 199.6974 A Vtrans = 1.996974 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:57 Magnet Current Measurement: Imag = 199.6925 +- 0.0077 A 14:11:57 Magnetic Field Measurement Measuring the magnet strength... 14:11:58 Integrated Voltage Measurement... 14:12:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006166227 Vs 14:12:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006548809 Vs 14:12:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006170717 Vs 14:12:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006539215 Vs 14:12:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006151688 Vs 14:13:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006557817 Vs 14:13:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006150774 Vs 14:13:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006558410 Vs 14:13:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006355457 +- 0.000001197 Vs 14:13:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006355457 +- 0.000001197 Vs BL = 0.63554572 +- 0.00011972 Tm 14:13:28 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.63555 0.00012 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.63555 0.00012 0.63555 0.00000 14:13:28 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.63555 0.00012 SL = 0.6355457 +- 0.0001197 Tm^2/m^n 14:13:28 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6355457 +- 0.0001197 Tm^2/m^n 14:13:30 Magnet Current, Imag = 199.7273 A Vtrans = 1.997273 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:31 Magnet Current, Imag = 199.6790 A Vtrans = 1.996790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:33 Magnet Current, Imag = 199.6758 A Vtrans = 1.996758 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:34 Magnet Current, Imag = 199.6770 A Vtrans = 1.996770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:34 Magnet Current Measurement: Imag = 199.6898 +- 0.0217 A 14:13:34 Magnet current ramping to 250.0000 A... 14:13:56 Magnet Current, Imag = 249.7675 A Vtrans = 2.497675 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:58 Magnet Current, Imag = 249.7498 A Vtrans = 2.497498 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:59 Magnet Current, Imag = 249.7727 A Vtrans = 2.497727 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:14:01 Magnet Current, Imag = 249.7662 A Vtrans = 2.497662 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:14:01 Magnet Current Measurement: Imag = 249.7640 +- 0.0086 A 14:14:01 Magnetic Field Measurement Measuring the magnet strength... 14:14:01 Integrated Voltage Measurement... 14:14:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007744465 Vs 14:14:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008137629 Vs 14:14:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007767692 Vs 14:14:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008131415 Vs 14:14:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007757653 Vs 14:15:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008143063 Vs 14:15:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007745201 Vs 14:15:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008151351 Vs 14:15:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007947308 +- 0.000003691 Vs 14:15:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.007947308 +- 0.000003691 Vs BL = 0.79473084 +- 0.00036907 Tm 14:15:31 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.79473 0.00037 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.79473 0.00037 0.79473 0.00000 14:15:31 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.79473 0.00037 SL = 0.7947308 +- 0.0003691 Tm^2/m^n 14:15:31 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7947308 +- 0.0003691 Tm^2/m^n 14:15:32 Magnet Current, Imag = 249.7496 A Vtrans = 2.497496 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:34 Magnet Current, Imag = 249.7659 A Vtrans = 2.497659 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:35 Magnet Current, Imag = 249.7919 A Vtrans = 2.497919 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:36 Magnet Current, Imag = 249.7539 A Vtrans = 2.497539 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:37 Magnet Current Measurement: Imag = 249.7653 +- 0.0165 A 14:15:37 Magnet current ramping to 300.0000 A... 14:15:59 Magnet Current, Imag = 299.8222 A Vtrans = 2.998222 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:16:00 Magnet Current, Imag = 299.8235 A Vtrans = 2.998235 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:16:02 Magnet Current, Imag = 299.7954 A Vtrans = 2.997954 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:16:03 Magnet Current, Imag = 299.7753 A Vtrans = 2.997753 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:16:03 Magnet Current Measurement: Imag = 299.8041 +- 0.0201 A 14:16:03 Magnetic Field Measurement Measuring the magnet strength... 14:16:03 Integrated Voltage Measurement... 14:16:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009338884 Vs 14:16:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009743543 Vs 14:16:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009342987 Vs 14:16:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009745209 Vs 14:16:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009356527 Vs 14:17:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009746594 Vs 14:17:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009339732 Vs 14:17:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009731803 Vs 14:17:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009543160 +- 0.000005698 Vs 14:17:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009543160 +- 0.000005698 Vs BL = 0.95431597 +- 0.00056983 Tm 14:17:33 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.95432 0.00057 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.95432 0.00057 0.95432 0.00000 14:17:33 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.95432 0.00057 SL = 0.9543160 +- 0.0005698 Tm^2/m^n 14:17:33 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9543160 +- 0.0005698 Tm^2/m^n 14:17:35 Magnet Current, Imag = 299.7929 A Vtrans = 2.997929 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:36 Magnet Current, Imag = 299.8188 A Vtrans = 2.998188 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:38 Magnet Current, Imag = 299.8208 A Vtrans = 2.998208 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:39 Magnet Current, Imag = 299.8119 A Vtrans = 2.998119 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:39 Magnet Current Measurement: Imag = 299.8111 +- 0.0110 A 14:17:39 Magnet current ramping to 350.0000 A... 14:18:02 Magnet Current, Imag = 349.8290 A Vtrans = 3.498290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:18:04 Magnet Current, Imag = 349.8520 A Vtrans = 3.498520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:18:06 Magnet Current, Imag = 349.8660 A Vtrans = 3.498660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:18:08 Magnet Current, Imag = 349.8630 A Vtrans = 3.498630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:18:08 Magnet Current Measurement: Imag = 349.8525 +- 0.0145 A 14:18:08 Magnetic Field Measurement Measuring the magnet strength... 14:18:08 Integrated Voltage Measurement... 14:18:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010941525 Vs 14:18:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011336834 Vs 14:18:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010958839 Vs 14:18:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011338971 Vs 14:19:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010945033 Vs 14:19:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011323778 Vs 14:19:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010938246 Vs 14:19:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011351945 Vs 14:19:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011141896 +- 0.000005542 Vs 14:19:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.011141896 +- 0.000005542 Vs BL = 1.11418963 +- 0.00055417 Tm 14:19:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.11419 0.00055 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.11419 0.00055 1.11419 0.00000 14:19:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.11419 0.00055 SL = 1.1141896 +- 0.0005542 Tm^2/m^n 14:19:38 Magnet Strength Measurement Harmonic Number = 1 SL = 1.1141896 +- 0.0005542 Tm^2/m^n 14:19:40 Magnet Current, Imag = 349.8920 A Vtrans = 3.498920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:42 Magnet Current, Imag = 349.8970 A Vtrans = 3.498970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:44 Magnet Current, Imag = 349.8760 A Vtrans = 3.498760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:46 Magnet Current, Imag = 349.8670 A Vtrans = 3.498670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:46 Magnet Current Measurement: Imag = 349.8830 +- 0.0121 A 14:19:46 Magnet current ramping to 400.0000 A... 14:20:09 Magnet Current, Imag = 399.8600 A Vtrans = 3.998600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:20:11 Magnet Current, Imag = 399.8690 A Vtrans = 3.998690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:20:12 Magnet Current, Imag = 399.8760 A Vtrans = 3.998760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:20:14 Magnet Current, Imag = 399.8680 A Vtrans = 3.998680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:20:14 Magnet Current Measurement: Imag = 399.8682 +- 0.0057 A 14:20:14 Magnetic Field Measurement Measuring the magnet strength... 14:20:14 Integrated Voltage Measurement... 14:20:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012515193 Vs 14:20:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012929845 Vs 14:20:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012529171 Vs 14:20:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012922426 Vs 14:21:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012531650 Vs 14:21:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012920814 Vs 14:21:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012537627 Vs 14:21:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012930820 Vs 14:21:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012727193 +- 0.000004305 Vs 14:21:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012727193 +- 0.000004305 Vs BL = 1.27271933 +- 0.00043054 Tm 14:21:44 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.27272 0.00043 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.27272 0.00043 1.27272 0.00000 14:21:44 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.27272 0.00043 SL = 1.2727193 +- 0.0004305 Tm^2/m^n 14:21:44 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2727193 +- 0.0004305 Tm^2/m^n 14:21:45 Magnet Current, Imag = 399.8970 A Vtrans = 3.998970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:47 Magnet Current, Imag = 399.9120 A Vtrans = 3.999120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:48 Magnet Current, Imag = 399.9030 A Vtrans = 3.999030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:50 Magnet Current, Imag = 399.8860 A Vtrans = 3.998860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:50 Magnet Current Measurement: Imag = 399.8995 +- 0.0094 A 14:21:50 Magnet current ramping to 450.0000 A... 14:22:14 Magnet Current, Imag = 449.9540 A Vtrans = 4.499540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:22:15 Magnet Current, Imag = 449.9600 A Vtrans = 4.499600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:22:17 Magnet Current, Imag = 449.9790 A Vtrans = 4.499790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:22:18 Magnet Current, Imag = 449.9540 A Vtrans = 4.499540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:22:19 Magnet Current Measurement: Imag = 449.9617 +- 0.0103 A 14:22:19 Magnetic Field Measurement Measuring the magnet strength... 14:22:19 Integrated Voltage Measurement... 14:22:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014119768 Vs 14:22:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014510839 Vs 14:22:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014131241 Vs 14:23:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014518129 Vs 14:23:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014128322 Vs 14:23:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014509485 Vs 14:23:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014116687 Vs 14:23:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014537967 Vs 14:23:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014321555 +- 0.000004723 Vs 14:23:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014321555 +- 0.000004723 Vs BL = 1.43215548 +- 0.00047229 Tm 14:23:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43216 0.00047 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.43216 0.00047 1.43216 0.00000 14:23:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43216 0.00047 SL = 1.4321555 +- 0.0004723 Tm^2/m^n 14:23:49 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4321555 +- 0.0004723 Tm^2/m^n 14:23:50 Magnet Current, Imag = 449.9240 A Vtrans = 4.499240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:23:52 Magnet Current, Imag = 449.9420 A Vtrans = 4.499420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:23:53 Magnet Current, Imag = 449.9450 A Vtrans = 4.499450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:23:56 Magnet Current, Imag = 449.9810 A Vtrans = 4.499810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:23:56 Magnet Current Measurement: Imag = 449.9480 +- 0.0207 A 14:23:56 Magnet current ramping to 500.0000 A... 14:24:20 Magnet Current, Imag = 499.9840 A Vtrans = 4.999840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:24:21 Magnet Current, Imag = 499.9980 A Vtrans = 4.999980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:24:23 Magnet Current, Imag = 499.9930 A Vtrans = 4.999930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:24:24 Magnet Current, Imag = 500.0020 A Vtrans = 5.000020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:24:24 Magnet Current Measurement: Imag = 499.9942 +- 0.0067 A 14:24:24 Magnetic Field Measurement Measuring the magnet strength... 14:24:24 Integrated Voltage Measurement... 14:24:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015685924 Vs 14:24:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016098083 Vs 14:24:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015700995 Vs 14:25:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016116117 Vs 14:25:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015724424 Vs 14:25:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016110824 Vs 14:25:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015695639 Vs 14:25:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016112290 Vs 14:25:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015905537 +- 0.000009231 Vs 14:25:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015905537 +- 0.000009231 Vs BL = 1.59055370 +- 0.00092310 Tm 14:25:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.59055 0.00092 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.59055 0.00092 1.59055 0.00000 14:25:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.59055 0.00092 SL = 1.5905537 +- 0.0009231 Tm^2/m^n 14:25:55 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5905537 +- 0.0009231 Tm^2/m^n 14:25:56 Magnet Current, Imag = 500.0240 A Vtrans = 5.000240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:25:58 Magnet Current, Imag = 500.0220 A Vtrans = 5.000220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:26:00 Magnet Current, Imag = 500.0070 A Vtrans = 5.000070 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:26:02 Magnet Current, Imag = 500.0380 A Vtrans = 5.000380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:26:02 Magnet Current Measurement: Imag = 500.0227 +- 0.0110 A 14:26:02 Magnet current ramping to 525.0000 A... 14:26:17 Magnet Current, Imag = 525.0790 A Vtrans = 5.250790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:26:19 Magnet Current, Imag = 525.0900 A Vtrans = 5.250900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:26:20 Magnet Current, Imag = 525.0840 A Vtrans = 5.250840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:26:22 Magnet Current, Imag = 525.0620 A Vtrans = 5.250620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:26:22 Magnet Current Measurement: Imag = 525.0788 +- 0.0104 A 14:26:22 Magnetic Field Measurement Measuring the magnet strength... 14:26:22 Integrated Voltage Measurement... 14:26:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016508521 Vs 14:26:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016890214 Vs 14:26:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016484089 Vs 14:27:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016885373 Vs 14:27:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016483761 Vs 14:27:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016888855 Vs 14:27:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016493633 Vs 14:27:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016882887 Vs 14:27:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016689667 +- 0.000005739 Vs 14:27:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016689667 +- 0.000005739 Vs BL = 1.66896667 +- 0.00057386 Tm 14:27:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.66897 0.00057 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.66897 0.00057 1.66897 0.00000 14:27:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.66897 0.00057 SL = 1.6689667 +- 0.0005739 Tm^2/m^n 14:27:54 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6689667 +- 0.0005739 Tm^2/m^n 14:27:55 Magnet Current, Imag = 525.0860 A Vtrans = 5.250860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:27:57 Magnet Current, Imag = 525.0640 A Vtrans = 5.250640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:27:58 Magnet Current, Imag = 525.0590 A Vtrans = 5.250590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:28:00 Magnet Current, Imag = 525.0630 A Vtrans = 5.250630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:28:00 Magnet Current Measurement: Imag = 525.0680 +- 0.0106 A 14:28:00 Magnet current ramping to 550.0000 A... 14:28:18 Magnet Current, Imag = 550.0180 A Vtrans = 5.500180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:28:20 Magnet Current, Imag = 550.0380 A Vtrans = 5.500380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:28:21 Magnet Current, Imag = 550.0440 A Vtrans = 5.500440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:28:23 Magnet Current, Imag = 550.0050 A Vtrans = 5.500050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:28:23 Magnet Current Measurement: Imag = 550.0263 +- 0.0156 A 14:28:23 Magnetic Field Measurement Measuring the magnet strength... 14:28:23 Integrated Voltage Measurement... 14:28:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017272519 Vs 14:28:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017659576 Vs 14:28:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017271795 Vs 14:29:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017680321 Vs 14:29:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017271567 Vs 14:29:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017671336 Vs 14:29:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017288244 Vs 14:29:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017679725 Vs 14:29:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017474385 +- 0.000006578 Vs 14:29:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017474385 +- 0.000006578 Vs BL = 1.74743854 +- 0.00065776 Tm 14:29:53 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.74744 0.00066 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.74744 0.00066 1.74744 0.00000 14:29:53 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.74744 0.00066 SL = 1.7474385 +- 0.0006578 Tm^2/m^n 14:29:53 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7474385 +- 0.0006578 Tm^2/m^n 14:29:54 Magnet Current, Imag = 550.0300 A Vtrans = 5.500300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:29:56 Magnet Current, Imag = 550.0500 A Vtrans = 5.500500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:29:57 Magnet Current, Imag = 550.0360 A Vtrans = 5.500360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:29:59 Magnet Current, Imag = 550.0360 A Vtrans = 5.500360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:29:59 Magnet Current Measurement: Imag = 550.0380 +- 0.0073 A 14:29:59 Magnet current ramping to 575.0000 A... 14:30:14 Magnet Current, Imag = 575.0160 A Vtrans = 5.750160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:30:16 Magnet Current, Imag = 575.0550 A Vtrans = 5.750550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:30:17 Magnet Current, Imag = 575.1010 A Vtrans = 5.751010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:30:19 Magnet Current, Imag = 575.0750 A Vtrans = 5.750750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:30:19 Magnet Current Measurement: Imag = 575.0617 +- 0.0310 A 14:30:19 Magnetic Field Measurement Measuring the magnet strength... 14:30:19 Integrated Voltage Measurement... 14:30:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018060115 Vs 14:30:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018426553 Vs 14:30:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018063552 Vs 14:31:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018426873 Vs 14:31:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018040741 Vs 14:31:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018431429 Vs 14:31:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018038605 Vs 14:31:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018444382 Vs 14:31:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018241531 +- 0.000003408 Vs 14:31:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.018241531 +- 0.000003408 Vs BL = 1.82415312 +- 0.00034082 Tm 14:31:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.82415 0.00034 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.82415 0.00034 1.82415 0.00000 14:31:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.82415 0.00034 SL = 1.8241531 +- 0.0003408 Tm^2/m^n 14:31:49 Magnet Strength Measurement Harmonic Number = 1 SL = 1.8241531 +- 0.0003408 Tm^2/m^n 14:31:51 Magnet Current, Imag = 575.1180 A Vtrans = 5.751180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:52 Magnet Current, Imag = 575.1310 A Vtrans = 5.751310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:54 Magnet Current, Imag = 575.1260 A Vtrans = 5.751260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:55 Magnet Current, Imag = 575.1270 A Vtrans = 5.751270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:55 Magnet Current Measurement: Imag = 575.1255 +- 0.0047 A 14:31:55 Magnet current ramping to 600.0000 A... 14:32:11 Magnet Current, Imag = 600.0610 A Vtrans = 6.000610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:32:12 Magnet Current, Imag = 600.0330 A Vtrans = 6.000330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:32:14 Magnet Current, Imag = 600.0420 A Vtrans = 6.000420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:32:15 Magnet Current, Imag = 600.0560 A Vtrans = 6.000560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:32:15 Magnet Current Measurement: Imag = 600.0480 +- 0.0111 A 14:32:15 Magnetic Field Measurement Measuring the magnet strength... 14:32:15 Integrated Voltage Measurement... 14:32:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018829243 Vs 14:32:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019206542 Vs 14:32:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018800815 Vs 14:33:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019212377 Vs 14:33:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018803467 Vs 14:33:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019205450 Vs 14:33:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018821656 Vs 14:33:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019199071 Vs 14:33:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019009828 +- 0.000005114 Vs 14:33:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019009828 +- 0.000005114 Vs BL = 1.90098276 +- 0.00051136 Tm 14:33:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.90098 0.00051 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.90098 0.00051 1.90098 0.00000 14:33:45 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.90098 0.00051 SL = 1.9009828 +- 0.0005114 Tm^2/m^n 14:33:45 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9009828 +- 0.0005114 Tm^2/m^n 14:33:47 Magnet Current, Imag = 600.0930 A Vtrans = 6.000930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:48 Magnet Current, Imag = 600.1180 A Vtrans = 6.001180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:50 Magnet Current, Imag = 600.0910 A Vtrans = 6.000910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:51 Magnet Current, Imag = 600.0600 A Vtrans = 6.000600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:51 Magnet Current Measurement: Imag = 600.0905 +- 0.0206 A 14:33:52 Magnet current ramping to 625.0000 A... 14:34:07 Magnet Current, Imag = 625.1590 A Vtrans = 6.251590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:34:08 Magnet Current, Imag = 625.1890 A Vtrans = 6.251890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:34:10 Magnet Current, Imag = 625.1910 A Vtrans = 6.251910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:34:11 Magnet Current, Imag = 625.1620 A Vtrans = 6.251620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:34:11 Magnet Current Measurement: Imag = 625.1753 +- 0.0148 A 14:34:11 Magnetic Field Measurement Measuring the magnet strength... 14:34:12 Integrated Voltage Measurement... 14:34:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019566908 Vs 14:34:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019931617 Vs 14:34:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019547603 Vs 14:34:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019954636 Vs 14:35:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019541605 Vs 14:35:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019946295 Vs 14:35:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019538788 Vs 14:35:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019966169 Vs 14:35:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019749203 +- 0.000003240 Vs 14:35:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019749203 +- 0.000003240 Vs BL = 1.97492025 +- 0.00032404 Tm 14:35:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.97492 0.00032 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.97492 0.00032 1.97492 0.00000 14:35:42 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.97492 0.00032 SL = 1.9749203 +- 0.0003240 Tm^2/m^n 14:35:42 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9749203 +- 0.0003240 Tm^2/m^n 14:35:43 Magnet Current, Imag = 625.1440 A Vtrans = 6.251440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:45 Magnet Current, Imag = 625.1460 A Vtrans = 6.251460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:46 Magnet Current, Imag = 625.1830 A Vtrans = 6.251830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:48 Magnet Current, Imag = 625.1660 A Vtrans = 6.251660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:48 Magnet Current Measurement: Imag = 625.1598 +- 0.0159 A 14:35:48 Magnet current ramping to 650.0000 A... 14:36:03 Magnet Current, Imag = 650.1410 A Vtrans = 6.501410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:36:05 Magnet Current, Imag = 650.1340 A Vtrans = 6.501340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:36:06 Magnet Current, Imag = 650.1500 A Vtrans = 6.501500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:36:08 Magnet Current, Imag = 650.1330 A Vtrans = 6.501330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:36:08 Magnet Current Measurement: Imag = 650.1395 +- 0.0068 A 14:36:08 Magnetic Field Measurement Measuring the magnet strength... 14:36:08 Integrated Voltage Measurement... 14:36:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020271343 Vs 14:36:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020658975 Vs 14:36:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020264328 Vs 14:36:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020655501 Vs 14:37:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020259863 Vs 14:37:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020663431 Vs 14:37:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020256401 Vs 14:37:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020654273 Vs 14:37:38 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020460514 +- 0.000003536 Vs 14:37:38 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020460514 +- 0.000003536 Vs BL = 2.04605143 +- 0.00035363 Tm 14:37:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.04605 0.00035 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.04605 0.00035 2.04605 0.00000 14:37:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.04605 0.00035 SL = 2.0460514 +- 0.0003536 Tm^2/m^n 14:37:41 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0460514 +- 0.0003536 Tm^2/m^n 14:37:42 Magnet Current, Imag = 650.1320 A Vtrans = 6.501320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:44 Magnet Current, Imag = 650.1540 A Vtrans = 6.501540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:45 Magnet Current, Imag = 650.1620 A Vtrans = 6.501620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:47 Magnet Current, Imag = 650.1650 A Vtrans = 6.501650 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:47 Magnet Current Measurement: Imag = 650.1532 +- 0.0129 A 14:37:47 Magnet current ramping to 675.0000 A... 14:38:02 Magnet Current, Imag = 675.2040 A Vtrans = 6.752040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:38:04 Magnet Current, Imag = 675.1960 A Vtrans = 6.751960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:38:05 Magnet Current, Imag = 675.1830 A Vtrans = 6.751830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:38:07 Magnet Current, Imag = 675.1810 A Vtrans = 6.751810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:38:07 Magnet Current Measurement: Imag = 675.1910 +- 0.0095 A 14:38:07 Magnetic Field Measurement Measuring the magnet strength... 14:38:07 Integrated Voltage Measurement... 14:38:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020938814 Vs 14:38:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021308057 Vs 14:38:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020923581 Vs 14:38:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021310963 Vs 14:39:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020946307 Vs 14:39:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021319983 Vs 14:39:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020933449 Vs 14:39:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021325275 Vs 14:39:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021125804 +- 0.000006020 Vs 14:39:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021125804 +- 0.000006020 Vs BL = 2.11258037 +- 0.00060201 Tm 14:39:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.11258 0.00060 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.11258 0.00060 2.11258 0.00000 14:39:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.11258 0.00060 SL = 2.1125804 +- 0.0006020 Tm^2/m^n 14:39:38 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1125804 +- 0.0006020 Tm^2/m^n 14:39:40 Magnet Current, Imag = 675.1930 A Vtrans = 6.751930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:41 Magnet Current, Imag = 675.2150 A Vtrans = 6.752150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:43 Magnet Current, Imag = 675.2590 A Vtrans = 6.752590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:44 Magnet Current, Imag = 675.2070 A Vtrans = 6.752070 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:44 Magnet Current Measurement: Imag = 675.2185 +- 0.0247 A 14:39:44 Magnet current ramping to 700.0000 A... 14:40:00 Magnet Current, Imag = 700.2590 A Vtrans = 7.002590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:40:01 Magnet Current, Imag = 700.2460 A Vtrans = 7.002460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:40:03 Magnet Current, Imag = 700.2380 A Vtrans = 7.002380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:40:04 Magnet Current, Imag = 700.2190 A Vtrans = 7.002190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:40:04 Magnet Current Measurement: Imag = 700.2405 +- 0.0145 A 14:40:04 Magnetic Field Measurement Measuring the magnet strength... 14:40:04 Integrated Voltage Measurement... 14:40:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021543745 Vs 14:40:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021948965 Vs 14:40:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021556355 Vs 14:40:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021945815 Vs 14:41:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021543201 Vs 14:41:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021934029 Vs 14:41:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021539137 Vs 14:41:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021941351 Vs 14:41:31 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021744075 +- 0.000004971 Vs 14:41:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021744075 +- 0.000004971 Vs BL = 2.17440747 +- 0.00049705 Tm 14:41:34 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.17441 0.00050 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.17441 0.00050 2.17441 0.00000 14:41:34 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.17441 0.00050 SL = 2.1744075 +- 0.0004971 Tm^2/m^n 14:41:34 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1744075 +- 0.0004971 Tm^2/m^n 14:41:36 Magnet Current, Imag = 700.1760 A Vtrans = 7.001760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:41:38 Magnet Current, Imag = 700.1840 A Vtrans = 7.001840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:41:39 Magnet Current, Imag = 700.1890 A Vtrans = 7.001890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:41:41 Magnet Current, Imag = 700.2170 A Vtrans = 7.002170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:41:41 Magnet Current Measurement: Imag = 700.1915 +- 0.0154 A 14:41:41 Magnet current ramping to 650.0000 A... 14:42:04 Magnet Current, Imag = 650.1240 A Vtrans = 6.501240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:42:06 Magnet Current, Imag = 650.1290 A Vtrans = 6.501290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:42:07 Magnet Current, Imag = 650.1380 A Vtrans = 6.501380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:42:09 Magnet Current, Imag = 650.1100 A Vtrans = 6.501100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:42:09 Magnet Current Measurement: Imag = 650.1253 +- 0.0101 A 14:42:09 Magnetic Field Measurement Measuring the magnet strength... 14:42:09 Integrated Voltage Measurement... 14:42:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020345248 Vs 14:42:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020735176 Vs 14:42:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020331677 Vs 14:42:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020750977 Vs 14:43:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020322310 Vs 14:43:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020727216 Vs 14:43:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020339909 Vs 14:43:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020738776 Vs 14:43:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020536411 +- 0.000006762 Vs 14:43:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020536411 +- 0.000006762 Vs BL = 2.05364112 +- 0.00067618 Tm 14:43:39 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.05364 0.00068 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.05364 0.00068 2.05364 0.00000 14:43:39 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.05364 0.00068 SL = 2.0536411 +- 0.0006762 Tm^2/m^n 14:43:39 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0536411 +- 0.0006762 Tm^2/m^n 14:43:41 Magnet Current, Imag = 650.1540 A Vtrans = 6.501540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:42 Magnet Current, Imag = 650.1480 A Vtrans = 6.501480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:44 Magnet Current, Imag = 650.1490 A Vtrans = 6.501490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:45 Magnet Current, Imag = 650.1710 A Vtrans = 6.501710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:45 Magnet Current Measurement: Imag = 650.1555 +- 0.0092 A 14:43:45 Magnet current ramping to 600.0000 A... 14:44:09 Magnet Current, Imag = 600.0980 A Vtrans = 6.000980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:44:11 Magnet Current, Imag = 600.0910 A Vtrans = 6.000910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:44:12 Magnet Current, Imag = 600.0930 A Vtrans = 6.000930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:44:14 Magnet Current, Imag = 600.0600 A Vtrans = 6.000600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:44:14 Magnet Current Measurement: Imag = 600.0855 +- 0.0149 A 14:44:14 Magnetic Field Measurement Measuring the magnet strength... 14:44:14 Integrated Voltage Measurement... 14:44:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018890562 Vs 14:44:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019294651 Vs 14:44:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018891861 Vs 14:45:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019280526 Vs 14:45:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018916841 Vs 14:45:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019296057 Vs 14:45:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018888745 Vs 14:45:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019276350 Vs 14:45:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019091949 +- 0.000009113 Vs 14:45:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019091949 +- 0.000009113 Vs BL = 1.90919490 +- 0.00091132 Tm 14:45:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.90919 0.00091 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.90919 0.00091 1.90919 0.00000 14:45:45 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.90919 0.00091 SL = 1.9091949 +- 0.0009113 Tm^2/m^n 14:45:45 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9091949 +- 0.0009113 Tm^2/m^n 14:45:47 Magnet Current, Imag = 600.1080 A Vtrans = 6.001080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:48 Magnet Current, Imag = 600.1140 A Vtrans = 6.001140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:50 Magnet Current, Imag = 600.0780 A Vtrans = 6.000780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:51 Magnet Current, Imag = 600.0590 A Vtrans = 6.000590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:51 Magnet Current Measurement: Imag = 600.0897 +- 0.0224 A 14:45:52 Magnet current ramping to 550.0000 A... 14:46:14 Magnet Current, Imag = 550.0380 A Vtrans = 5.500380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:46:16 Magnet Current, Imag = 550.0520 A Vtrans = 5.500520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:46:17 Magnet Current, Imag = 550.0910 A Vtrans = 5.500910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:46:19 Magnet Current, Imag = 550.0470 A Vtrans = 5.500470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:46:19 Magnet Current Measurement: Imag = 550.0570 +- 0.0203 A 14:46:19 Magnetic Field Measurement Measuring the magnet strength... 14:46:19 Integrated Voltage Measurement... 14:46:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017338942 Vs 14:46:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017713197 Vs 14:46:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017349929 Vs 14:47:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017728549 Vs 14:47:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017343925 Vs 14:47:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017740900 Vs 14:47:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017350948 Vs 14:47:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017746739 Vs 14:47:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017539141 +- 0.000008302 Vs 14:47:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017539141 +- 0.000008302 Vs BL = 1.75391411 +- 0.00083022 Tm 14:47:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.75391 0.00083 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.75391 0.00083 1.75391 0.00000 14:47:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.75391 0.00083 SL = 1.7539141 +- 0.0008302 Tm^2/m^n 14:47:49 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7539141 +- 0.0008302 Tm^2/m^n 14:47:51 Magnet Current, Imag = 550.0380 A Vtrans = 5.500380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:47:52 Magnet Current, Imag = 550.0510 A Vtrans = 5.500510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:47:54 Magnet Current, Imag = 550.0730 A Vtrans = 5.500730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:47:55 Magnet Current, Imag = 550.1120 A Vtrans = 5.501120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:47:55 Magnet Current Measurement: Imag = 550.0685 +- 0.0281 A 14:47:55 Magnet current ramping to 500.0000 A... 14:48:18 Magnet Current, Imag = 500.0550 A Vtrans = 5.000550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:48:20 Magnet Current, Imag = 500.0450 A Vtrans = 5.000450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:48:21 Magnet Current, Imag = 500.0450 A Vtrans = 5.000450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:48:23 Magnet Current, Imag = 500.0510 A Vtrans = 5.000510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:48:23 Magnet Current Measurement: Imag = 500.0490 +- 0.0042 A 14:48:23 Magnetic Field Measurement Measuring the magnet strength... 14:48:23 Integrated Voltage Measurement... 14:48:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015785071 Vs 14:48:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016151598 Vs 14:48:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015780380 Vs 14:49:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016167003 Vs 14:49:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015768767 Vs 14:49:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016173489 Vs 14:49:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015756626 Vs 14:49:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016182771 Vs 14:49:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015970713 +- 0.000001983 Vs 14:49:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015970713 +- 0.000001983 Vs BL = 1.59707132 +- 0.00019831 Tm 14:49:53 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.59707 0.00020 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.59707 0.00020 1.59707 0.00000 14:49:53 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.59707 0.00020 SL = 1.5970713 +- 0.0001983 Tm^2/m^n 14:49:53 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5970713 +- 0.0001983 Tm^2/m^n 14:49:55 Magnet Current, Imag = 500.0190 A Vtrans = 5.000190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:56 Magnet Current, Imag = 500.0280 A Vtrans = 5.000280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:58 Magnet Current, Imag = 500.0340 A Vtrans = 5.000340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:59 Magnet Current, Imag = 500.0510 A Vtrans = 5.000510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:59 Magnet Current Measurement: Imag = 500.0330 +- 0.0117 A 14:50:00 Magnet current ramping to 450.0000 A... 14:50:23 Magnet Current, Imag = 449.9630 A Vtrans = 4.499630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:50:25 Magnet Current, Imag = 449.9480 A Vtrans = 4.499480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:50:26 Magnet Current, Imag = 449.9470 A Vtrans = 4.499470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:50:28 Magnet Current, Imag = 449.9490 A Vtrans = 4.499490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:50:28 Magnet Current Measurement: Imag = 449.9517 +- 0.0065 A 14:50:28 Magnetic Field Measurement Measuring the magnet strength... 14:50:28 Integrated Voltage Measurement... 14:50:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014174731 Vs 14:50:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014561511 Vs 14:51:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014177320 Vs 14:51:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014572720 Vs 14:51:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014184403 Vs 14:51:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014564763 Vs 14:51:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014191601 Vs 14:51:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014587219 Vs 14:51:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014376784 +- 0.000007785 Vs 14:51:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014376784 +- 0.000007785 Vs BL = 1.43767836 +- 0.00077850 Tm 14:51:58 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43768 0.00078 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.43768 0.00078 1.43768 0.00000 14:51:58 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43768 0.00078 SL = 1.4376784 +- 0.0007785 Tm^2/m^n 14:51:58 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4376784 +- 0.0007785 Tm^2/m^n 14:52:00 Magnet Current, Imag = 449.9640 A Vtrans = 4.499640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:52:01 Magnet Current, Imag = 449.9640 A Vtrans = 4.499640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:52:03 Magnet Current, Imag = 449.9510 A Vtrans = 4.499510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:52:04 Magnet Current, Imag = 449.9800 A Vtrans = 4.499800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:52:04 Magnet Current Measurement: Imag = 449.9647 +- 0.0103 A 14:52:04 Magnet current ramping to 400.0000 A... 14:52:28 Magnet Current, Imag = 399.8910 A Vtrans = 3.998910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:52:30 Magnet Current, Imag = 399.9100 A Vtrans = 3.999100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:52:31 Magnet Current, Imag = 399.8990 A Vtrans = 3.998990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:52:33 Magnet Current, Imag = 399.9160 A Vtrans = 3.999160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:52:33 Magnet Current Measurement: Imag = 399.9040 +- 0.0097 A 14:52:33 Magnetic Field Measurement Measuring the magnet strength... 14:52:33 Integrated Voltage Measurement... 14:52:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012589822 Vs 14:52:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012971860 Vs 14:53:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012578799 Vs 14:53:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012982747 Vs 14:53:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012588942 Vs 14:53:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012985195 Vs 14:53:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012576847 Vs 14:54:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012962605 Vs 14:54:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012779602 +- 0.000006249 Vs 14:54:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012779602 +- 0.000006249 Vs BL = 1.27796022 +- 0.00062488 Tm 14:54:03 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.27796 0.00062 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.27796 0.00062 1.27796 0.00000 14:54:03 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.27796 0.00062 SL = 1.2779602 +- 0.0006249 Tm^2/m^n 14:54:03 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2779602 +- 0.0006249 Tm^2/m^n 14:54:05 Magnet Current, Imag = 399.9230 A Vtrans = 3.999230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:54:06 Magnet Current, Imag = 399.9290 A Vtrans = 3.999290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:54:08 Magnet Current, Imag = 399.9360 A Vtrans = 3.999360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:54:09 Magnet Current, Imag = 399.9170 A Vtrans = 3.999170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:54:09 Magnet Current Measurement: Imag = 399.9262 +- 0.0070 A 14:54:39 Magnet current ramping to 0.0000 A...