SLAC Magnetic Measurements Date: 05-21-2001 Time: 12:34:35 Project: spear3 Magnet Type: gdipole Magnet Name: 145d-005 Serial Number: Run Number: 8 Measurement Device: stretched wire Operator: jy Comment: BL vs. I, mains Standardization: 1 cycles from 0.0 A to 770.0 A to 0.0 A Test Currents (A): 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 500.0 525.0 550.0 575.0 600.0 625.0 650.0 675.0 700.0 12:34:48 Initial Zero Current Measurement, Imag_zero = 0.0000 A 12:34:48 Magnet current ramping to 15.0000 A... 12:35:19 Magnet current ramping to 770.0000 A... 12:39:33 Magnet current ramping to 0.0000 A... 12:43:52 Magnet current ramping to 50.0000 A... 12:44:15 Magnet Current, Imag = 50.0919 A Vtrans = 0.500919 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:44:17 Magnet Current, Imag = 49.9724 A Vtrans = 0.499724 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:44:18 Magnet Current, Imag = 49.8541 A Vtrans = 0.498541 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:44:20 Magnet Current, Imag = 49.9555 A Vtrans = 0.499555 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:44:20 Magnet Current Measurement: Imag = 49.9685 +- 0.0844 A 12:44:20 Magnetic Field Measurement Measuring the magnet strength... 12:44:20 Integrated Voltage Measurement... 12:44:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002675170 Vs 12:44:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000551013 Vs 12:44:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002673215 Vs 12:45:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000508957 Vs 12:45:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002688529 Vs 12:45:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000560293 Vs 12:45:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002656623 Vs 12:45:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000523179 Vs 12:45:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001604623 +- 0.000014691 Vs 12:45:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001604623 +- 0.000014691 Vs BL = 0.16046225 +- 0.00146907 Tm 12:45:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.16046 0.00147 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.16046 0.00147 0.16046 0.00000 12:45:51 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.16046 0.00147 SL = 0.1604623 +- 0.0014691 Tm^2/m^n 12:45:51 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1604623 +- 0.0014691 Tm^2/m^n 12:45:53 Magnet Current, Imag = 49.9208 A Vtrans = 0.499208 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:45:54 Magnet Current, Imag = 49.9660 A Vtrans = 0.499660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:45:56 Magnet Current, Imag = 49.9178 A Vtrans = 0.499178 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:45:57 Magnet Current, Imag = 49.8971 A Vtrans = 0.498971 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:45:58 Magnet Current Measurement: Imag = 49.9254 +- 0.0251 A 12:45:58 Magnet current ramping to 100.0000 A... 12:46:21 Magnet Current, Imag = 99.9333 A Vtrans = 0.999333 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:46:22 Magnet Current, Imag = 99.9573 A Vtrans = 0.999573 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:46:23 Magnet Current, Imag = 99.9760 A Vtrans = 0.999760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:46:25 Magnet Current, Imag = 99.9938 A Vtrans = 0.999938 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:46:25 Magnet Current Measurement: Imag = 99.9651 +- 0.0224 A 12:46:25 Magnetic Field Measurement Measuring the magnet strength... 12:46:25 Integrated Voltage Measurement... 12:46:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004269853 Vs 12:46:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002088217 Vs 12:47:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004277698 Vs 12:47:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002086857 Vs 12:47:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004262685 Vs 12:47:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002086844 Vs 12:47:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004248006 Vs 12:47:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002104606 Vs 12:47:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003178096 +- 0.000002858 Vs 12:47:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.003178096 +- 0.000002858 Vs BL = 0.31780958 +- 0.00028578 Tm 12:47:57 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.31781 0.00029 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.31781 0.00029 0.31781 0.00000 12:47:57 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.31781 0.00029 SL = 0.3178096 +- 0.0002858 Tm^2/m^n 12:47:57 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3178096 +- 0.0002858 Tm^2/m^n 12:47:59 Magnet Current, Imag = 99.9833 A Vtrans = 0.999833 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:48:00 Magnet Current, Imag = 99.9964 A Vtrans = 0.999964 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:48:01 Magnet Current, Imag = 99.9314 A Vtrans = 0.999314 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:48:03 Magnet Current, Imag = 99.9383 A Vtrans = 0.999383 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:48:03 Magnet Current Measurement: Imag = 99.9624 +- 0.0280 A 12:48:03 Magnet current ramping to 150.0000 A... 12:48:26 Magnet Current, Imag = 149.9896 A Vtrans = 1.499896 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:48:27 Magnet Current, Imag = 150.0047 A Vtrans = 1.500047 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:48:29 Magnet Current, Imag = 150.0112 A Vtrans = 1.500112 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:48:30 Magnet Current, Imag = 150.0076 A Vtrans = 1.500076 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:48:30 Magnet Current Measurement: Imag = 150.0033 +- 0.0082 A 12:48:31 Magnetic Field Measurement Measuring the magnet strength... 12:48:31 Integrated Voltage Measurement... 12:48:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005860371 Vs 12:48:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003689891 Vs 12:49:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005858995 Vs 12:49:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003677253 Vs 12:49:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005858419 Vs 12:49:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003674555 Vs 12:49:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005856018 Vs 12:49:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003679637 Vs 12:49:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004769392 +- 0.000003370 Vs 12:49:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004769392 +- 0.000003370 Vs BL = 0.47693923 +- 0.00033701 Tm 12:50:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.47694 0.00034 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.47694 0.00034 0.47694 0.00000 12:50:02 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.47694 0.00034 SL = 0.4769392 +- 0.0003370 Tm^2/m^n 12:50:02 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4769392 +- 0.0003370 Tm^2/m^n 12:50:04 Magnet Current, Imag = 149.9814 A Vtrans = 1.499814 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:50:05 Magnet Current, Imag = 149.9905 A Vtrans = 1.499905 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:50:07 Magnet Current, Imag = 149.9755 A Vtrans = 1.499755 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:50:08 Magnet Current, Imag = 150.0120 A Vtrans = 1.500120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:50:09 Magnet Current Measurement: Imag = 149.9898 +- 0.0139 A 12:50:09 Magnet current ramping to 200.0000 A... 12:50:32 Magnet Current, Imag = 200.0354 A Vtrans = 2.000354 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:50:33 Magnet Current, Imag = 200.0356 A Vtrans = 2.000356 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:50:34 Magnet Current, Imag = 200.0206 A Vtrans = 2.000206 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:50:36 Magnet Current, Imag = 200.0303 A Vtrans = 2.000303 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:50:36 Magnet Current Measurement: Imag = 200.0305 +- 0.0061 A 12:50:36 Magnetic Field Measurement Measuring the magnet strength... 12:50:36 Integrated Voltage Measurement... 12:50:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007447899 Vs 12:51:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005296025 Vs 12:51:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007432377 Vs 12:51:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005283101 Vs 12:51:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007446698 Vs 12:51:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005282462 Vs 12:51:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007433655 Vs 12:52:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005284685 Vs 12:52:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006363363 +- 0.000005582 Vs 12:52:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006363363 +- 0.000005582 Vs BL = 0.63633628 +- 0.00055821 Tm 12:52:08 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.63634 0.00056 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.63634 0.00056 0.63634 0.00000 12:52:08 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.63634 0.00056 SL = 0.6363363 +- 0.0005582 Tm^2/m^n 12:52:08 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6363363 +- 0.0005582 Tm^2/m^n 12:52:09 Magnet Current, Imag = 199.9991 A Vtrans = 1.999991 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:52:11 Magnet Current, Imag = 200.0177 A Vtrans = 2.000177 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:52:12 Magnet Current, Imag = 200.0128 A Vtrans = 2.000128 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:52:14 Magnet Current, Imag = 199.9916 A Vtrans = 1.999916 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:52:14 Magnet Current Measurement: Imag = 200.0053 +- 0.0104 A 12:52:14 Magnet current ramping to 250.0000 A... 12:52:37 Magnet Current, Imag = 250.0345 A Vtrans = 2.500345 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:52:38 Magnet Current, Imag = 250.0340 A Vtrans = 2.500340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:52:40 Magnet Current, Imag = 250.0680 A Vtrans = 2.500680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:52:41 Magnet Current, Imag = 250.0537 A Vtrans = 2.500537 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:52:41 Magnet Current Measurement: Imag = 250.0476 +- 0.0142 A 12:52:41 Magnetic Field Measurement Measuring the magnet strength... 12:52:41 Integrated Voltage Measurement... 12:52:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009048637 Vs 12:53:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006881399 Vs 12:53:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009040683 Vs 12:53:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006880015 Vs 12:53:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009037926 Vs 12:53:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006871762 Vs 12:53:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009043685 Vs 12:54:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006875398 Vs 12:54:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007959938 +- 0.000003608 Vs 12:54:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.007959938 +- 0.000003608 Vs BL = 0.79599382 +- 0.00036084 Tm 12:54:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.79599 0.00036 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.79599 0.00036 0.79599 0.00000 12:54:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.79599 0.00036 SL = 0.7959938 +- 0.0003608 Tm^2/m^n 12:54:13 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7959938 +- 0.0003608 Tm^2/m^n 12:54:15 Magnet Current, Imag = 250.0582 A Vtrans = 2.500582 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:54:16 Magnet Current, Imag = 250.0497 A Vtrans = 2.500497 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:54:17 Magnet Current, Imag = 250.0423 A Vtrans = 2.500423 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:54:19 Magnet Current, Imag = 250.0189 A Vtrans = 2.500189 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:54:19 Magnet Current Measurement: Imag = 250.0423 +- 0.0146 A 12:54:19 Magnet current ramping to 300.0000 A... 12:54:42 Magnet Current, Imag = 300.0358 A Vtrans = 3.000358 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:54:44 Magnet Current, Imag = 300.0508 A Vtrans = 3.000508 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:54:45 Magnet Current, Imag = 300.0822 A Vtrans = 3.000822 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:54:47 Magnet Current, Imag = 300.0885 A Vtrans = 3.000885 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:54:47 Magnet Current Measurement: Imag = 300.0643 +- 0.0218 A 12:54:47 Magnetic Field Measurement Measuring the magnet strength... 12:54:47 Integrated Voltage Measurement... 12:55:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010638753 Vs 12:55:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008486237 Vs 12:55:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010648461 Vs 12:55:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008470391 Vs 12:55:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010643698 Vs 12:55:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008470191 Vs 12:56:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010630141 Vs 12:56:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008468118 Vs 12:56:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009556999 +- 0.000004951 Vs 12:56:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009556999 +- 0.000004951 Vs BL = 0.95569989 +- 0.00049507 Tm 12:56:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.95570 0.00050 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.95570 0.00050 0.95570 0.00000 12:56:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.95570 0.00050 SL = 0.9556999 +- 0.0004951 Tm^2/m^n 12:56:18 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9556999 +- 0.0004951 Tm^2/m^n 12:56:20 Magnet Current, Imag = 300.0703 A Vtrans = 3.000703 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:56:21 Magnet Current, Imag = 300.0785 A Vtrans = 3.000785 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:56:23 Magnet Current, Imag = 300.0859 A Vtrans = 3.000859 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:56:24 Magnet Current, Imag = 300.0959 A Vtrans = 3.000959 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:56:24 Magnet Current Measurement: Imag = 300.0827 +- 0.0094 A 12:56:25 Magnet current ramping to 350.0000 A... 12:56:48 Magnet Current, Imag = 350.0860 A Vtrans = 3.500860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:56:50 Magnet Current, Imag = 350.0800 A Vtrans = 3.500800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:56:52 Magnet Current, Imag = 350.1130 A Vtrans = 3.501130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:56:54 Magnet Current, Imag = 350.1290 A Vtrans = 3.501290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:56:54 Magnet Current Measurement: Imag = 350.1020 +- 0.0199 A 12:56:54 Magnetic Field Measurement Measuring the magnet strength... 12:56:54 Integrated Voltage Measurement... 12:57:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012194824 Vs 12:57:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.010076313 Vs 12:57:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012227247 Vs 12:57:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.010093216 Vs 12:57:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012215435 Vs 12:58:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.010076549 Vs 12:58:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012237452 Vs 12:58:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.010061254 Vs 12:58:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011147786 +- 0.000008801 Vs 12:58:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.011147786 +- 0.000008801 Vs BL = 1.11477863 +- 0.00088010 Tm 12:58:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.11478 0.00088 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.11478 0.00088 1.11478 0.00000 12:58:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.11478 0.00088 SL = 1.1147786 +- 0.0008801 Tm^2/m^n 12:58:26 Magnet Strength Measurement Harmonic Number = 1 SL = 1.1147786 +- 0.0008801 Tm^2/m^n 12:58:28 Magnet Current, Imag = 350.0920 A Vtrans = 3.500920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:58:30 Magnet Current, Imag = 350.1240 A Vtrans = 3.501240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:58:32 Magnet Current, Imag = 350.0860 A Vtrans = 3.500860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:58:34 Magnet Current, Imag = 350.1020 A Vtrans = 3.501020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:58:34 Magnet Current Measurement: Imag = 350.1010 +- 0.0145 A 12:58:34 Magnet current ramping to 400.0000 A... 12:58:58 Magnet Current, Imag = 400.0720 A Vtrans = 4.000720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:58:59 Magnet Current, Imag = 400.1070 A Vtrans = 4.001070 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:59:01 Magnet Current, Imag = 400.1200 A Vtrans = 4.001200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:59:02 Magnet Current, Imag = 400.1080 A Vtrans = 4.001080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:59:02 Magnet Current Measurement: Imag = 400.1017 +- 0.0179 A 12:59:03 Magnetic Field Measurement Measuring the magnet strength... 12:59:03 Integrated Voltage Measurement... 12:59:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013794089 Vs 12:59:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011659837 Vs 12:59:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013826599 Vs 12:59:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011660237 Vs 12:59:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013824013 Vs 13:00:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011645194 Vs 13:00:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013808077 Vs 13:00:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011670653 Vs 13:00:31 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012736087 +- 0.000006122 Vs 13:00:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012736087 +- 0.000006122 Vs BL = 1.27360874 +- 0.00061224 Tm 13:00:35 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.27361 0.00061 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.27361 0.00061 1.27361 0.00000 13:00:35 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.27361 0.00061 SL = 1.2736087 +- 0.0006122 Tm^2/m^n 13:00:35 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2736087 +- 0.0006122 Tm^2/m^n 13:00:36 Magnet Current, Imag = 400.1140 A Vtrans = 4.001140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:00:38 Magnet Current, Imag = 400.1300 A Vtrans = 4.001300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:00:39 Magnet Current, Imag = 400.1430 A Vtrans = 4.001430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:00:41 Magnet Current, Imag = 400.1470 A Vtrans = 4.001470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:00:41 Magnet Current Measurement: Imag = 400.1335 +- 0.0129 A 13:00:41 Magnet current ramping to 450.0000 A... 13:01:04 Magnet Current, Imag = 450.1380 A Vtrans = 4.501380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:01:06 Magnet Current, Imag = 450.1080 A Vtrans = 4.501080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:01:08 Magnet Current, Imag = 450.1350 A Vtrans = 4.501350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:01:09 Magnet Current, Imag = 450.1570 A Vtrans = 4.501570 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:01:09 Magnet Current Measurement: Imag = 450.1345 +- 0.0175 A 13:01:09 Magnetic Field Measurement Measuring the magnet strength... 13:01:09 Integrated Voltage Measurement... 13:01:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015405393 Vs 13:01:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013256010 Vs 13:01:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015394238 Vs 13:01:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013251781 Vs 13:02:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015393174 Vs 13:02:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013239116 Vs 13:02:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015404999 Vs 13:02:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013244049 Vs 13:02:38 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014323595 +- 0.000005177 Vs 13:02:38 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014323595 +- 0.000005177 Vs BL = 1.43235951 +- 0.00051772 Tm 13:02:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43236 0.00052 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.43236 0.00052 1.43236 0.00000 13:02:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43236 0.00052 SL = 1.4323595 +- 0.0005177 Tm^2/m^n 13:02:41 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4323595 +- 0.0005177 Tm^2/m^n 13:02:43 Magnet Current, Imag = 450.1530 A Vtrans = 4.501530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:02:45 Magnet Current, Imag = 450.1450 A Vtrans = 4.501450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:02:46 Magnet Current, Imag = 450.1530 A Vtrans = 4.501530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:02:48 Magnet Current, Imag = 450.1320 A Vtrans = 4.501320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:02:48 Magnet Current Measurement: Imag = 450.1458 +- 0.0086 A 13:02:48 Magnet current ramping to 500.0000 A... 13:03:11 Magnet Current, Imag = 500.1890 A Vtrans = 5.001890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:03:13 Magnet Current, Imag = 500.1810 A Vtrans = 5.001810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:03:14 Magnet Current, Imag = 500.1680 A Vtrans = 5.001680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:03:16 Magnet Current, Imag = 500.1730 A Vtrans = 5.001730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:03:16 Magnet Current Measurement: Imag = 500.1777 +- 0.0080 A 13:03:16 Magnetic Field Measurement Measuring the magnet strength... 13:03:16 Integrated Voltage Measurement... 13:03:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016991425 Vs 13:03:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014842641 Vs 13:03:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016987027 Vs 13:04:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014831599 Vs 13:04:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016974584 Vs 13:04:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014843792 Vs 13:04:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016996946 Vs 13:04:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014822061 Vs 13:04:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015911259 +- 0.000003335 Vs 13:04:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015911259 +- 0.000003335 Vs BL = 1.59112593 +- 0.00033351 Tm 13:04:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.59113 0.00033 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.59113 0.00033 1.59113 0.00000 13:04:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.59113 0.00033 SL = 1.5911259 +- 0.0003335 Tm^2/m^n 13:04:48 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5911259 +- 0.0003335 Tm^2/m^n 13:04:50 Magnet Current, Imag = 500.1850 A Vtrans = 5.001850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:04:51 Magnet Current, Imag = 500.1950 A Vtrans = 5.001950 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:04:53 Magnet Current, Imag = 500.1740 A Vtrans = 5.001740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:04:54 Magnet Current, Imag = 500.1640 A Vtrans = 5.001640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:04:54 Magnet Current Measurement: Imag = 500.1795 +- 0.0116 A 13:04:55 Magnet current ramping to 525.0000 A... 13:05:10 Magnet Current, Imag = 525.1590 A Vtrans = 5.251590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:05:12 Magnet Current, Imag = 525.1920 A Vtrans = 5.251920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:05:14 Magnet Current, Imag = 525.2040 A Vtrans = 5.252040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:05:15 Magnet Current, Imag = 525.1990 A Vtrans = 5.251990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:05:15 Magnet Current Measurement: Imag = 525.1885 +- 0.0176 A 13:05:15 Magnetic Field Measurement Measuring the magnet strength... 13:05:16 Integrated Voltage Measurement... 13:05:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017779471 Vs 13:05:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015624200 Vs 13:05:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017795172 Vs 13:06:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015601270 Vs 13:06:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017782851 Vs 13:06:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015630677 Vs 13:06:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017771361 Vs 13:06:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015628930 Vs 13:06:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016701742 +- 0.000003169 Vs 13:06:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016701742 +- 0.000003169 Vs BL = 1.67017417 +- 0.00031693 Tm 13:06:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.67017 0.00032 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.67017 0.00032 1.67017 0.00000 13:06:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.67017 0.00032 SL = 1.6701742 +- 0.0003169 Tm^2/m^n 13:06:48 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6701742 +- 0.0003169 Tm^2/m^n 13:06:49 Magnet Current, Imag = 525.2410 A Vtrans = 5.252410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:06:51 Magnet Current, Imag = 525.2110 A Vtrans = 5.252110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:06:52 Magnet Current, Imag = 525.2210 A Vtrans = 5.252210 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:06:54 Magnet Current, Imag = 525.2130 A Vtrans = 5.252130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:06:54 Magnet Current Measurement: Imag = 525.2215 +- 0.0119 A 13:06:54 Magnet current ramping to 550.0000 A... 13:07:10 Magnet Current, Imag = 550.1040 A Vtrans = 5.501040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:07:12 Magnet Current, Imag = 550.1390 A Vtrans = 5.501390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:07:13 Magnet Current, Imag = 550.1840 A Vtrans = 5.501840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:07:15 Magnet Current, Imag = 550.1940 A Vtrans = 5.501940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:07:15 Magnet Current Measurement: Imag = 550.1553 +- 0.0361 A 13:07:15 Magnetic Field Measurement Measuring the magnet strength... 13:07:15 Integrated Voltage Measurement... 13:07:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018556936 Vs 13:07:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016395769 Vs 13:07:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018550196 Vs 13:08:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016399862 Vs 13:08:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018556541 Vs 13:08:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016405615 Vs 13:08:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018536385 Vs 13:08:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016416907 Vs 13:08:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017477276 +- 0.000002278 Vs 13:08:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017477276 +- 0.000002278 Vs BL = 1.74772763 +- 0.00022778 Tm 13:08:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.74773 0.00023 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.74773 0.00023 1.74773 0.00000 13:08:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.74773 0.00023 SL = 1.7477276 +- 0.0002278 Tm^2/m^n 13:08:47 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7477276 +- 0.0002278 Tm^2/m^n 13:08:49 Magnet Current, Imag = 550.1560 A Vtrans = 5.501560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:50 Magnet Current, Imag = 550.1660 A Vtrans = 5.501660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:52 Magnet Current, Imag = 550.1630 A Vtrans = 5.501630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:54 Magnet Current, Imag = 550.1820 A Vtrans = 5.501820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:54 Magnet Current Measurement: Imag = 550.1667 +- 0.0095 A 13:08:54 Magnet current ramping to 575.0000 A... 13:09:10 Magnet Current, Imag = 575.1680 A Vtrans = 5.751680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:09:11 Magnet Current, Imag = 575.1850 A Vtrans = 5.751850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:09:13 Magnet Current, Imag = 575.2030 A Vtrans = 5.752030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:09:14 Magnet Current, Imag = 575.1930 A Vtrans = 5.751930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:09:15 Magnet Current Measurement: Imag = 575.1872 +- 0.0128 A 13:09:15 Magnetic Field Measurement Measuring the magnet strength... 13:09:15 Integrated Voltage Measurement... 13:09:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019337941 Vs 13:09:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017162984 Vs 13:09:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019326274 Vs 13:10:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017178697 Vs 13:10:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019348689 Vs 13:10:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017174003 Vs 13:10:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019327182 Vs 13:10:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017188559 Vs 13:10:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018255541 +- 0.000004308 Vs 13:10:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.018255541 +- 0.000004308 Vs BL = 1.82555410 +- 0.00043085 Tm 13:10:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.82555 0.00043 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.82555 0.00043 1.82555 0.00000 13:10:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.82555 0.00043 SL = 1.8255541 +- 0.0004308 Tm^2/m^n 13:10:47 Magnet Strength Measurement Harmonic Number = 1 SL = 1.8255541 +- 0.0004308 Tm^2/m^n 13:10:49 Magnet Current, Imag = 575.2060 A Vtrans = 5.752060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:50 Magnet Current, Imag = 575.2110 A Vtrans = 5.752110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:52 Magnet Current, Imag = 575.2160 A Vtrans = 5.752160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:53 Magnet Current, Imag = 575.2170 A Vtrans = 5.752170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:53 Magnet Current Measurement: Imag = 575.2125 +- 0.0044 A 13:10:54 Magnet current ramping to 600.0000 A... 13:11:09 Magnet Current, Imag = 600.2440 A Vtrans = 6.002440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:11:11 Magnet Current, Imag = 600.2270 A Vtrans = 6.002270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:11:12 Magnet Current, Imag = 600.2010 A Vtrans = 6.002010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:11:14 Magnet Current, Imag = 600.1970 A Vtrans = 6.001970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:11:14 Magnet Current Measurement: Imag = 600.2173 +- 0.0193 A 13:11:14 Magnetic Field Measurement Measuring the magnet strength... 13:11:14 Integrated Voltage Measurement... 13:11:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020115894 Vs 13:11:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017947421 Vs 13:11:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020082537 Vs 13:12:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017948767 Vs 13:12:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020081193 Vs 13:12:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017848542 Vs 13:12:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020088348 Vs 13:12:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017952506 Vs 13:12:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019008151 +- 0.000025656 Vs 13:12:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019008151 +- 0.000025656 Vs BL = 1.90081510 +- 0.00256564 Tm 13:12:50 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.90082 0.00257 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.90082 0.00257 1.90082 0.00000 13:12:50 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.90082 0.00257 SL = 1.9008151 +- 0.0025656 Tm^2/m^n 13:12:50 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9008151 +- 0.0025656 Tm^2/m^n 13:12:52 Magnet Current, Imag = 600.1890 A Vtrans = 6.001890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:12:54 Magnet Current, Imag = 600.1750 A Vtrans = 6.001750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:12:55 Magnet Current, Imag = 600.1750 A Vtrans = 6.001750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:12:57 Magnet Current, Imag = 600.1930 A Vtrans = 6.001930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:12:57 Magnet Current Measurement: Imag = 600.1830 +- 0.0081 A 13:12:57 Magnet current ramping to 625.0000 A... 13:13:13 Magnet Current, Imag = 625.2660 A Vtrans = 6.252660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:13:14 Magnet Current, Imag = 625.2700 A Vtrans = 6.252700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:13:16 Magnet Current, Imag = 625.2540 A Vtrans = 6.252540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:13:17 Magnet Current, Imag = 625.2360 A Vtrans = 6.252360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:13:17 Magnet Current Measurement: Imag = 625.2565 +- 0.0132 A 13:13:18 Magnetic Field Measurement Measuring the magnet strength... 13:13:18 Integrated Voltage Measurement... 13:13:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020808313 Vs 13:13:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018676994 Vs 13:13:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020803830 Vs 13:14:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018676631 Vs 13:14:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020801369 Vs 13:14:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018701987 Vs 13:14:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020808134 Vs 13:14:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018689303 Vs 13:14:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019745820 +- 0.000004582 Vs 13:14:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019745820 +- 0.000004582 Vs BL = 1.97458202 +- 0.00045821 Tm 13:14:50 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.97458 0.00046 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.97458 0.00046 1.97458 0.00000 13:14:50 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.97458 0.00046 SL = 1.9745820 +- 0.0004582 Tm^2/m^n 13:14:50 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9745820 +- 0.0004582 Tm^2/m^n 13:14:51 Magnet Current, Imag = 625.2270 A Vtrans = 6.252270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:14:53 Magnet Current, Imag = 625.2570 A Vtrans = 6.252570 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:14:54 Magnet Current, Imag = 625.2390 A Vtrans = 6.252390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:14:56 Magnet Current, Imag = 625.1950 A Vtrans = 6.251950 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:14:56 Magnet Current Measurement: Imag = 625.2295 +- 0.0226 A 13:14:56 Magnet current ramping to 650.0000 A... 13:15:12 Magnet Current, Imag = 650.2980 A Vtrans = 6.502980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:15:14 Magnet Current, Imag = 650.2940 A Vtrans = 6.502940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:15:15 Magnet Current, Imag = 650.2910 A Vtrans = 6.502910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:15:17 Magnet Current, Imag = 650.3120 A Vtrans = 6.503120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:15:17 Magnet Current Measurement: Imag = 650.2988 +- 0.0080 A 13:15:17 Magnetic Field Measurement Measuring the magnet strength... 13:15:17 Integrated Voltage Measurement... 13:15:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021514175 Vs 13:15:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019397718 Vs 13:15:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021512033 Vs 13:16:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019392819 Vs 13:16:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021506017 Vs 13:16:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019420951 Vs 13:16:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021519276 Vs 13:16:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019392043 Vs 13:16:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020456879 +- 0.000004056 Vs 13:16:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020456879 +- 0.000004056 Vs BL = 2.04568791 +- 0.00040562 Tm 13:16:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.04569 0.00041 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.04569 0.00041 2.04569 0.00000 13:16:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.04569 0.00041 SL = 2.0456879 +- 0.0004056 Tm^2/m^n 13:16:50 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0456879 +- 0.0004056 Tm^2/m^n 13:16:51 Magnet Current, Imag = 650.1780 A Vtrans = 6.501780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:16:53 Magnet Current, Imag = 650.2280 A Vtrans = 6.502280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:16:54 Magnet Current, Imag = 650.2280 A Vtrans = 6.502280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:16:56 Magnet Current, Imag = 650.2870 A Vtrans = 6.502870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:16:56 Magnet Current Measurement: Imag = 650.2302 +- 0.0386 A 13:16:56 Magnet current ramping to 675.0000 A... 13:17:12 Magnet Current, Imag = 675.3230 A Vtrans = 6.753230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:17:13 Magnet Current, Imag = 675.2880 A Vtrans = 6.752880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:17:15 Magnet Current, Imag = 675.3040 A Vtrans = 6.753040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:17:17 Magnet Current, Imag = 675.2560 A Vtrans = 6.752560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:17:17 Magnet Current Measurement: Imag = 675.2927 +- 0.0246 A 13:17:17 Magnetic Field Measurement Measuring the magnet strength... 13:17:17 Integrated Voltage Measurement... 13:17:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.022169578 Vs 13:17:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020056925 Vs 13:17:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.022205966 Vs 13:18:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020045124 Vs 13:18:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.022187884 Vs 13:18:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020063909 Vs 13:18:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.022195263 Vs 13:18:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020054969 Vs 13:18:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021122452 +- 0.000005319 Vs 13:18:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021122452 +- 0.000005319 Vs BL = 2.11224522 +- 0.00053193 Tm 13:18:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.11225 0.00053 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.11225 0.00053 2.11225 0.00000 13:18:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.11225 0.00053 SL = 2.1122452 +- 0.0005319 Tm^2/m^n 13:18:49 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1122452 +- 0.0005319 Tm^2/m^n 13:18:51 Magnet Current, Imag = 675.2980 A Vtrans = 6.752980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:18:52 Magnet Current, Imag = 675.3240 A Vtrans = 6.753240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:18:54 Magnet Current, Imag = 675.3290 A Vtrans = 6.753290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:18:55 Magnet Current, Imag = 675.3000 A Vtrans = 6.753000 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:18:55 Magnet Current Measurement: Imag = 675.3127 +- 0.0139 A 13:18:56 Magnet current ramping to 700.0000 A... 13:19:11 Magnet Current, Imag = 700.2950 A Vtrans = 7.002950 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:19:13 Magnet Current, Imag = 700.3040 A Vtrans = 7.003040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:19:14 Magnet Current, Imag = 700.3100 A Vtrans = 7.003100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:19:16 Magnet Current, Imag = 700.3000 A Vtrans = 7.003000 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:19:16 Magnet Current Measurement: Imag = 700.3022 +- 0.0055 A 13:19:16 Magnetic Field Measurement Measuring the magnet strength... 13:19:16 Integrated Voltage Measurement... 13:19:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.022802017 Vs 13:19:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020673653 Vs 13:19:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.022794285 Vs 13:20:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020687774 Vs 13:20:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.022793591 Vs 13:20:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020682129 Vs 13:20:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.022814056 Vs 13:20:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020688105 Vs 13:20:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021741951 +- 0.000005428 Vs 13:20:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021741951 +- 0.000005428 Vs BL = 2.17419512 +- 0.00054284 Tm 13:20:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.17420 0.00054 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.17420 0.00054 2.17420 0.00000 13:20:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.17420 0.00054 SL = 2.1741951 +- 0.0005428 Tm^2/m^n 13:20:48 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1741951 +- 0.0005428 Tm^2/m^n 13:20:50 Magnet Current, Imag = 700.2750 A Vtrans = 7.002750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:20:51 Magnet Current, Imag = 700.3100 A Vtrans = 7.003100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:20:53 Magnet Current, Imag = 700.3130 A Vtrans = 7.003130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:20:55 Magnet Current, Imag = 700.2580 A Vtrans = 7.002580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:20:55 Magnet Current Measurement: Imag = 700.2890 +- 0.0233 A 13:20:56 Magnet current ramping to 0.0000 A...