SLAC Magnetic Measurements Date: 05-24-2001 Time: 12:15:06 Project: spear3 Magnet Type: gdipole Magnet Name: 145d-002 Serial Number: Run Number: 6 Measurement Device: stretched wire Operator: jy Comment: BL vs. I, mains Standardization: 1 cycles from 0.0 A to 770.0 A to 0.0 A Test Currents (A): 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 500.0 525.0 550.0 575.0 600.0 625.0 650.0 675.0 700.0 650.0 600.0 550.0 500.0 450.0 400.0 12:15:15 Initial Zero Current Measurement, Imag_zero = 0.0000 A 12:15:15 Magnet current ramping to 15.0000 A... 12:15:47 Magnet current ramping to 770.0000 A... 12:19:59 Magnet current ramping to 0.0000 A... 12:24:45 Magnet current ramping to 50.0000 A... 12:25:08 Magnet Current, Imag = 61.5780 A Vtrans = 0.615780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:10 Magnet Current, Imag = 46.4861 A Vtrans = 0.464861 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:11 Magnet Current, Imag = 47.7322 A Vtrans = 0.477322 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:13 Magnet Current, Imag = 51.3951 A Vtrans = 0.513951 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:13 Magnet Current Measurement: Imag = 51.7979 +- 5.9279 A 12:25:13 Magnetic Field Measurement Measuring the magnet strength... 12:25:13 Integrated Voltage Measurement... 12:25:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002757392 Vs 12:25:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000527743 Vs 12:25:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002676600 Vs 12:25:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000537031 Vs 12:26:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002651745 Vs 12:26:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000535238 Vs 12:26:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002678878 Vs 12:26:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000527297 Vs 12:26:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001611491 +- 0.000018589 Vs 12:26:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001611491 +- 0.000018589 Vs BL = 0.16114905 +- 0.00185889 Tm 12:26:44 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.16115 0.00186 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.16115 0.00186 0.16115 0.00000 12:26:44 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.16115 0.00186 SL = 0.1611491 +- 0.0018589 Tm^2/m^n 12:26:44 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1611491 +- 0.0018589 Tm^2/m^n 12:26:46 Magnet Current, Imag = 49.8045 A Vtrans = 0.498045 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:26:47 Magnet Current, Imag = 49.8408 A Vtrans = 0.498408 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:26:49 Magnet Current, Imag = 49.8433 A Vtrans = 0.498433 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:26:50 Magnet Current, Imag = 49.8444 A Vtrans = 0.498444 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:26:50 Magnet Current Measurement: Imag = 49.8332 +- 0.0166 A 12:26:50 Magnet current ramping to 100.0000 A... 12:27:13 Magnet Current, Imag = 99.8575 A Vtrans = 0.998575 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:15 Magnet Current, Imag = 99.8505 A Vtrans = 0.998505 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:16 Magnet Current, Imag = 99.8693 A Vtrans = 0.998693 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:17 Magnet Current, Imag = 99.8723 A Vtrans = 0.998723 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:18 Magnet Current Measurement: Imag = 99.8624 +- 0.0088 A 12:27:18 Magnetic Field Measurement Measuring the magnet strength... 12:27:18 Integrated Voltage Measurement... 12:27:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004237289 Vs 12:27:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002115374 Vs 12:27:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004242095 Vs 12:28:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002106787 Vs 12:28:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004249067 Vs 12:28:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002116578 Vs 12:28:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004236926 Vs 12:28:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002107365 Vs 12:28:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003176435 +- 0.000003974 Vs 12:28:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.003176435 +- 0.000003974 Vs BL = 0.31764350 +- 0.00039745 Tm 12:28:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.31764 0.00040 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.31764 0.00040 0.31764 0.00000 12:28:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.31764 0.00040 SL = 0.3176435 +- 0.0003974 Tm^2/m^n 12:28:49 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3176435 +- 0.0003974 Tm^2/m^n 12:28:51 Magnet Current, Imag = 99.8406 A Vtrans = 0.998406 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:28:52 Magnet Current, Imag = 99.8445 A Vtrans = 0.998445 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:28:53 Magnet Current, Imag = 99.8449 A Vtrans = 0.998449 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:28:55 Magnet Current, Imag = 99.8061 A Vtrans = 0.998061 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:28:55 Magnet Current Measurement: Imag = 99.8340 +- 0.0162 A 12:28:55 Magnet current ramping to 150.0000 A... 12:29:18 Magnet Current, Imag = 149.8890 A Vtrans = 1.498890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:19 Magnet Current, Imag = 149.8776 A Vtrans = 1.498776 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:21 Magnet Current, Imag = 149.8760 A Vtrans = 1.498760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:22 Magnet Current, Imag = 149.8864 A Vtrans = 1.498864 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:22 Magnet Current Measurement: Imag = 149.8822 +- 0.0056 A 12:29:23 Magnetic Field Measurement Measuring the magnet strength... 12:29:23 Integrated Voltage Measurement... 12:29:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005823715 Vs 12:29:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003711610 Vs 12:29:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005808713 Vs 12:30:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003707721 Vs 12:30:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005830966 Vs 12:30:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003723027 Vs 12:30:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005828463 Vs 12:30:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003716357 Vs 12:30:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004768821 +- 0.000006955 Vs 12:30:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004768821 +- 0.000006955 Vs BL = 0.47688214 +- 0.00069553 Tm 12:30:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.47688 0.00070 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.47688 0.00070 0.47688 0.00000 12:30:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.47688 0.00070 SL = 0.4768821 +- 0.0006955 Tm^2/m^n 12:30:54 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4768821 +- 0.0006955 Tm^2/m^n 12:30:55 Magnet Current, Imag = 149.8399 A Vtrans = 1.498399 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:30:57 Magnet Current, Imag = 149.8667 A Vtrans = 1.498667 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:30:58 Magnet Current, Imag = 149.9024 A Vtrans = 1.499024 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:00 Magnet Current, Imag = 149.9006 A Vtrans = 1.499006 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:00 Magnet Current Measurement: Imag = 149.8774 +- 0.0259 A 12:31:00 Magnet current ramping to 200.0000 A... 12:31:23 Magnet Current, Imag = 199.8775 A Vtrans = 1.998775 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:24 Magnet Current, Imag = 199.8962 A Vtrans = 1.998962 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:26 Magnet Current, Imag = 199.8925 A Vtrans = 1.998925 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:27 Magnet Current, Imag = 199.8985 A Vtrans = 1.998985 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:27 Magnet Current Measurement: Imag = 199.8912 +- 0.0082 A 12:31:27 Magnetic Field Measurement Measuring the magnet strength... 12:31:27 Integrated Voltage Measurement... 12:31:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007407725 Vs 12:31:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005287283 Vs 12:32:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007428190 Vs 12:32:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005299347 Vs 12:32:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007422645 Vs 12:32:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005291122 Vs 12:32:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007415757 Vs 12:32:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005306229 Vs 12:32:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006357287 +- 0.000006157 Vs 12:32:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006357287 +- 0.000006157 Vs BL = 0.63572873 +- 0.00061566 Tm 12:32:59 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.63573 0.00062 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.63573 0.00062 0.63573 0.00000 12:32:59 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.63573 0.00062 SL = 0.6357287 +- 0.0006157 Tm^2/m^n 12:32:59 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6357287 +- 0.0006157 Tm^2/m^n 12:33:00 Magnet Current, Imag = 199.8794 A Vtrans = 1.998794 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:02 Magnet Current, Imag = 199.8834 A Vtrans = 1.998834 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:03 Magnet Current, Imag = 199.9029 A Vtrans = 1.999029 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:05 Magnet Current, Imag = 199.9067 A Vtrans = 1.999067 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:05 Magnet Current Measurement: Imag = 199.8931 +- 0.0119 A 12:33:05 Magnet current ramping to 250.0000 A... 12:33:28 Magnet Current, Imag = 249.9167 A Vtrans = 2.499167 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:29 Magnet Current, Imag = 249.9159 A Vtrans = 2.499159 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:30 Magnet Current, Imag = 249.9280 A Vtrans = 2.499280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:32 Magnet Current, Imag = 249.9197 A Vtrans = 2.499197 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:32 Magnet Current Measurement: Imag = 249.9201 +- 0.0048 A 12:33:32 Magnetic Field Measurement Measuring the magnet strength... 12:33:32 Integrated Voltage Measurement... 12:33:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009004915 Vs 12:33:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006891722 Vs 12:34:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009010776 Vs 12:34:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006885383 Vs 12:34:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009010071 Vs 12:34:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006919161 Vs 12:34:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009025353 Vs 12:35:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006893827 Vs 12:35:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007955151 +- 0.000007176 Vs 12:35:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.007955151 +- 0.000007176 Vs BL = 0.79551510 +- 0.00071758 Tm 12:35:03 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.79552 0.00072 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.79552 0.00072 0.79552 0.00000 12:35:03 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.79552 0.00072 SL = 0.7955151 +- 0.0007176 Tm^2/m^n 12:35:03 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7955151 +- 0.0007176 Tm^2/m^n 12:35:05 Magnet Current, Imag = 249.9128 A Vtrans = 2.499128 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:06 Magnet Current, Imag = 249.9333 A Vtrans = 2.499333 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:08 Magnet Current, Imag = 249.9419 A Vtrans = 2.499419 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:09 Magnet Current, Imag = 249.9265 A Vtrans = 2.499265 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:09 Magnet Current Measurement: Imag = 249.9286 +- 0.0106 A 12:35:10 Magnet current ramping to 300.0000 A... 12:35:32 Magnet Current, Imag = 299.9229 A Vtrans = 2.999229 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:34 Magnet Current, Imag = 299.9054 A Vtrans = 2.999054 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:35 Magnet Current, Imag = 299.9216 A Vtrans = 2.999216 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:37 Magnet Current, Imag = 299.9426 A Vtrans = 2.999426 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:37 Magnet Current Measurement: Imag = 299.9231 +- 0.0132 A 12:35:37 Magnetic Field Measurement Measuring the magnet strength... 12:35:37 Integrated Voltage Measurement... 12:35:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010601285 Vs 12:36:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008487601 Vs 12:36:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010619397 Vs 12:36:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008471129 Vs 12:36:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010609827 Vs 12:36:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008492627 Vs 12:36:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010615385 Vs 12:37:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008482093 Vs 12:37:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009547418 +- 0.000002727 Vs 12:37:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009547418 +- 0.000002727 Vs BL = 0.95474182 +- 0.00027271 Tm 12:37:08 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.95474 0.00027 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.95474 0.00027 0.95474 0.00000 12:37:08 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.95474 0.00027 SL = 0.9547418 +- 0.0002727 Tm^2/m^n 12:37:08 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9547418 +- 0.0002727 Tm^2/m^n 12:37:10 Magnet Current, Imag = 299.9664 A Vtrans = 2.999664 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:37:11 Magnet Current, Imag = 299.9613 A Vtrans = 2.999613 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:37:13 Magnet Current, Imag = 299.9612 A Vtrans = 2.999612 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:37:14 Magnet Current, Imag = 299.9541 A Vtrans = 2.999541 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:37:14 Magnet Current Measurement: Imag = 299.9607 +- 0.0044 A 12:37:15 Magnet current ramping to 350.0000 A... 12:37:38 Magnet Current, Imag = 349.9860 A Vtrans = 3.499860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:37:40 Magnet Current, Imag = 349.9900 A Vtrans = 3.499900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:37:42 Magnet Current, Imag = 349.9840 A Vtrans = 3.499840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:37:44 Magnet Current, Imag = 349.9770 A Vtrans = 3.499770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:37:44 Magnet Current Measurement: Imag = 349.9842 +- 0.0047 A 12:37:44 Magnetic Field Measurement Measuring the magnet strength... 12:37:44 Integrated Voltage Measurement... 12:37:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012227407 Vs 12:38:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.010058373 Vs 12:38:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012212410 Vs 12:38:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.010059973 Vs 12:38:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012233611 Vs 12:38:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.010091638 Vs 12:39:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012212051 Vs 12:39:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.010081497 Vs 12:39:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011147120 +- 0.000009719 Vs 12:39:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.011147120 +- 0.000009719 Vs BL = 1.11471200 +- 0.00097190 Tm 12:39:16 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.11471 0.00097 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.11471 0.00097 1.11471 0.00000 12:39:16 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.11471 0.00097 SL = 1.1147120 +- 0.0009719 Tm^2/m^n 12:39:16 Magnet Strength Measurement Harmonic Number = 1 SL = 1.1147120 +- 0.0009719 Tm^2/m^n 12:39:18 Magnet Current, Imag = 349.9960 A Vtrans = 3.499960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:39:20 Magnet Current, Imag = 349.9620 A Vtrans = 3.499620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:39:22 Magnet Current, Imag = 349.9620 A Vtrans = 3.499620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:39:24 Magnet Current, Imag = 349.9500 A Vtrans = 3.499500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:39:24 Magnet Current Measurement: Imag = 349.9675 +- 0.0172 A 12:39:24 Magnet current ramping to 400.0000 A... 12:39:47 Magnet Current, Imag = 399.9690 A Vtrans = 3.999690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:39:49 Magnet Current, Imag = 399.9640 A Vtrans = 3.999640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:39:50 Magnet Current, Imag = 399.9970 A Vtrans = 3.999970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:39:52 Magnet Current, Imag = 400.0130 A Vtrans = 4.000130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:39:52 Magnet Current Measurement: Imag = 399.9857 +- 0.0201 A 12:39:52 Magnetic Field Measurement Measuring the magnet strength... 12:39:52 Integrated Voltage Measurement... 12:40:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013800917 Vs 12:40:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011681714 Vs 12:40:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013815531 Vs 12:40:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011675186 Vs 12:40:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013781307 Vs 12:40:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011672993 Vs 12:41:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013819318 Vs 12:41:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011667446 Vs 12:41:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012739302 +- 0.000007160 Vs 12:41:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012739302 +- 0.000007160 Vs BL = 1.27393016 +- 0.00071599 Tm 12:41:23 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.27393 0.00072 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.27393 0.00072 1.27393 0.00000 12:41:24 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.27393 0.00072 SL = 1.2739302 +- 0.0007160 Tm^2/m^n 12:41:24 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2739302 +- 0.0007160 Tm^2/m^n 12:41:25 Magnet Current, Imag = 399.9760 A Vtrans = 3.999760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:41:27 Magnet Current, Imag = 399.9690 A Vtrans = 3.999690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:41:28 Magnet Current, Imag = 399.9740 A Vtrans = 3.999740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:41:30 Magnet Current, Imag = 399.9660 A Vtrans = 3.999660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:41:30 Magnet Current Measurement: Imag = 399.9712 +- 0.0040 A 12:41:30 Magnet current ramping to 450.0000 A... 12:41:53 Magnet Current, Imag = 449.9780 A Vtrans = 4.499780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:41:55 Magnet Current, Imag = 449.9700 A Vtrans = 4.499700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:41:56 Magnet Current, Imag = 449.9810 A Vtrans = 4.499810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:41:58 Magnet Current, Imag = 449.9660 A Vtrans = 4.499660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:41:58 Magnet Current Measurement: Imag = 449.9737 +- 0.0060 A 12:41:58 Magnetic Field Measurement Measuring the magnet strength... 12:41:58 Integrated Voltage Measurement... 12:42:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015401220 Vs 12:42:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013267310 Vs 12:42:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015385855 Vs 12:42:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013252052 Vs 12:42:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015398413 Vs 12:43:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013269073 Vs 12:43:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015387557 Vs 12:43:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013258388 Vs 12:43:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014327483 +- 0.000006676 Vs 12:43:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014327483 +- 0.000006676 Vs BL = 1.43274834 +- 0.00066760 Tm 12:43:30 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43275 0.00067 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.43275 0.00067 1.43275 0.00000 12:43:30 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43275 0.00067 SL = 1.4327483 +- 0.0006676 Tm^2/m^n 12:43:30 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4327483 +- 0.0006676 Tm^2/m^n 12:43:31 Magnet Current, Imag = 450.0110 A Vtrans = 4.500110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:43:33 Magnet Current, Imag = 450.0090 A Vtrans = 4.500090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:43:35 Magnet Current, Imag = 449.9930 A Vtrans = 4.499930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:43:36 Magnet Current, Imag = 449.9860 A Vtrans = 4.499860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:43:36 Magnet Current Measurement: Imag = 449.9997 +- 0.0106 A 12:43:36 Magnet current ramping to 500.0000 A... 12:44:00 Magnet Current, Imag = 500.0660 A Vtrans = 5.000660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:44:01 Magnet Current, Imag = 500.0610 A Vtrans = 5.000610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:44:03 Magnet Current, Imag = 500.0740 A Vtrans = 5.000740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:44:04 Magnet Current, Imag = 500.0700 A Vtrans = 5.000700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:44:04 Magnet Current Measurement: Imag = 500.0677 +- 0.0048 A 12:44:04 Magnetic Field Measurement Measuring the magnet strength... 12:44:05 Integrated Voltage Measurement... 12:44:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016976934 Vs 12:44:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014837836 Vs 12:44:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016977753 Vs 12:44:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014830618 Vs 12:45:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016973109 Vs 12:45:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014858020 Vs 12:45:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016965939 Vs 12:45:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014837067 Vs 12:45:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015907160 +- 0.000005280 Vs 12:45:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015907160 +- 0.000005280 Vs BL = 1.59071595 +- 0.00052804 Tm 12:45:36 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.59072 0.00053 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.59072 0.00053 1.59072 0.00000 12:45:36 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.59072 0.00053 SL = 1.5907160 +- 0.0005280 Tm^2/m^n 12:45:36 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5907160 +- 0.0005280 Tm^2/m^n 12:45:38 Magnet Current, Imag = 500.0510 A Vtrans = 5.000510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:45:39 Magnet Current, Imag = 500.0430 A Vtrans = 5.000430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:45:41 Magnet Current, Imag = 500.0310 A Vtrans = 5.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:45:42 Magnet Current, Imag = 500.0250 A Vtrans = 5.000250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:45:42 Magnet Current Measurement: Imag = 500.0375 +- 0.0101 A 12:45:43 Magnet current ramping to 525.0000 A... 12:45:58 Magnet Current, Imag = 525.0140 A Vtrans = 5.250140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:46:00 Magnet Current, Imag = 525.0420 A Vtrans = 5.250420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:46:02 Magnet Current, Imag = 525.0710 A Vtrans = 5.250710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:46:03 Magnet Current, Imag = 525.1160 A Vtrans = 5.251160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:46:03 Magnet Current Measurement: Imag = 525.0607 +- 0.0377 A 12:46:03 Magnetic Field Measurement Measuring the magnet strength... 12:46:03 Integrated Voltage Measurement... 12:46:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017760506 Vs 12:46:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015628211 Vs 12:46:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017762648 Vs 12:46:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015651050 Vs 12:46:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017751608 Vs 12:47:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015614725 Vs 12:47:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017749705 Vs 12:47:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015640304 Vs 12:47:32 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016694845 +- 0.000008378 Vs 12:47:32 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016694845 +- 0.000008378 Vs BL = 1.66948446 +- 0.00083777 Tm 12:47:35 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.66948 0.00084 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.66948 0.00084 1.66948 0.00000 12:47:35 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.66948 0.00084 SL = 1.6694845 +- 0.0008378 Tm^2/m^n 12:47:35 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6694845 +- 0.0008378 Tm^2/m^n 12:47:37 Magnet Current, Imag = 525.0470 A Vtrans = 5.250470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:47:38 Magnet Current, Imag = 525.0270 A Vtrans = 5.250270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:47:40 Magnet Current, Imag = 525.0440 A Vtrans = 5.250440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:47:41 Magnet Current, Imag = 525.0600 A Vtrans = 5.250600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:47:41 Magnet Current Measurement: Imag = 525.0445 +- 0.0118 A 12:47:42 Magnet current ramping to 550.0000 A... 12:47:57 Magnet Current, Imag = 549.9610 A Vtrans = 5.499610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:47:59 Magnet Current, Imag = 550.0020 A Vtrans = 5.500020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:48:00 Magnet Current, Imag = 550.0290 A Vtrans = 5.500290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:48:02 Magnet Current, Imag = 550.0090 A Vtrans = 5.500090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:48:02 Magnet Current Measurement: Imag = 550.0002 +- 0.0247 A 12:48:02 Magnetic Field Measurement Measuring the magnet strength... 12:48:02 Integrated Voltage Measurement... 12:48:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018546335 Vs 12:48:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016394465 Vs 12:48:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018544069 Vs 12:48:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016404131 Vs 12:48:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018537845 Vs 12:49:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016420201 Vs 12:49:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018534756 Vs 12:49:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016415190 Vs 12:49:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017474624 +- 0.000003065 Vs 12:49:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017474624 +- 0.000003065 Vs BL = 1.74746240 +- 0.00030654 Tm 12:49:34 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.74746 0.00031 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.74746 0.00031 1.74746 0.00000 12:49:34 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.74746 0.00031 SL = 1.7474624 +- 0.0003065 Tm^2/m^n 12:49:34 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7474624 +- 0.0003065 Tm^2/m^n 12:49:35 Magnet Current, Imag = 550.0530 A Vtrans = 5.500530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:49:37 Magnet Current, Imag = 550.0940 A Vtrans = 5.500940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:49:38 Magnet Current, Imag = 550.0850 A Vtrans = 5.500850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:49:40 Magnet Current, Imag = 550.0880 A Vtrans = 5.500880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:49:40 Magnet Current Measurement: Imag = 550.0800 +- 0.0159 A 12:49:40 Magnet current ramping to 575.0000 A... 12:49:56 Magnet Current, Imag = 575.0370 A Vtrans = 5.750370 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:49:58 Magnet Current, Imag = 575.0710 A Vtrans = 5.750710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:49:59 Magnet Current, Imag = 575.0760 A Vtrans = 5.750760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:50:01 Magnet Current, Imag = 575.0500 A Vtrans = 5.750500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:50:01 Magnet Current Measurement: Imag = 575.0585 +- 0.0158 A 12:50:01 Magnetic Field Measurement Measuring the magnet strength... 12:50:01 Integrated Voltage Measurement... 12:50:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019301650 Vs 12:50:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017193431 Vs 12:50:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019311336 Vs 12:50:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017198213 Vs 12:50:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019299342 Vs 12:51:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017192087 Vs 12:51:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019294998 Vs 12:51:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017191568 Vs 12:51:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018247828 +- 0.000004285 Vs 12:51:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.018247828 +- 0.000004285 Vs BL = 1.82478282 +- 0.00042854 Tm 12:51:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.82478 0.00043 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.82478 0.00043 1.82478 0.00000 12:51:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.82478 0.00043 SL = 1.8247828 +- 0.0004285 Tm^2/m^n 12:51:32 Magnet Strength Measurement Harmonic Number = 1 SL = 1.8247828 +- 0.0004285 Tm^2/m^n 12:51:34 Magnet Current, Imag = 575.1020 A Vtrans = 5.751020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:51:36 Magnet Current, Imag = 575.0900 A Vtrans = 5.750900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:51:37 Magnet Current, Imag = 575.0750 A Vtrans = 5.750750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:51:39 Magnet Current, Imag = 575.0510 A Vtrans = 5.750510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:51:39 Magnet Current Measurement: Imag = 575.0795 +- 0.0190 A 12:51:39 Magnet current ramping to 600.0000 A... 12:51:55 Magnet Current, Imag = 600.0990 A Vtrans = 6.000990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:51:56 Magnet Current, Imag = 600.0760 A Vtrans = 6.000760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:51:58 Magnet Current, Imag = 600.0870 A Vtrans = 6.000870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:51:59 Magnet Current, Imag = 600.0880 A Vtrans = 6.000880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:52:00 Magnet Current Measurement: Imag = 600.0875 +- 0.0081 A 12:52:00 Magnetic Field Measurement Measuring the magnet strength... 12:52:00 Integrated Voltage Measurement... 12:52:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020068207 Vs 12:52:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017954123 Vs 12:52:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020070542 Vs 12:52:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017938331 Vs 12:52:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020066236 Vs 12:53:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017944596 Vs 12:53:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020062993 Vs 12:53:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017975153 Vs 12:53:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019010023 +- 0.000005823 Vs 12:53:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019010023 +- 0.000005823 Vs BL = 1.90100227 +- 0.00058232 Tm 12:53:31 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.90100 0.00058 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.90100 0.00058 1.90100 0.00000 12:53:31 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.90100 0.00058 SL = 1.9010023 +- 0.0005823 Tm^2/m^n 12:53:31 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9010023 +- 0.0005823 Tm^2/m^n 12:53:33 Magnet Current, Imag = 600.0600 A Vtrans = 6.000600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:53:34 Magnet Current, Imag = 600.0870 A Vtrans = 6.000870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:53:36 Magnet Current, Imag = 600.0420 A Vtrans = 6.000420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:53:38 Magnet Current, Imag = 600.0690 A Vtrans = 6.000690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:53:38 Magnet Current Measurement: Imag = 600.0645 +- 0.0162 A 12:53:38 Magnet current ramping to 625.0000 A... 12:53:53 Magnet Current, Imag = 625.1270 A Vtrans = 6.251270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:53:55 Magnet Current, Imag = 625.1640 A Vtrans = 6.251640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:53:57 Magnet Current, Imag = 625.1440 A Vtrans = 6.251440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:53:58 Magnet Current, Imag = 625.1290 A Vtrans = 6.251290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:53:58 Magnet Current Measurement: Imag = 625.1410 +- 0.0148 A 12:53:58 Magnetic Field Measurement Measuring the magnet strength... 12:53:58 Integrated Voltage Measurement... 12:54:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020824740 Vs 12:54:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018667181 Vs 12:54:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020827373 Vs 12:54:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018676770 Vs 12:54:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020814744 Vs 12:55:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018695189 Vs 12:55:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020842376 Vs 12:55:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018694694 Vs 12:55:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019755383 +- 0.000008260 Vs 12:55:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019755383 +- 0.000008260 Vs BL = 1.97553834 +- 0.00082598 Tm 12:55:30 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.97554 0.00083 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.97554 0.00083 1.97554 0.00000 12:55:30 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.97554 0.00083 SL = 1.9755383 +- 0.0008260 Tm^2/m^n 12:55:30 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9755383 +- 0.0008260 Tm^2/m^n 12:55:32 Magnet Current, Imag = 625.0990 A Vtrans = 6.250990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:55:33 Magnet Current, Imag = 625.0810 A Vtrans = 6.250810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:55:35 Magnet Current, Imag = 625.1090 A Vtrans = 6.251090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:55:36 Magnet Current, Imag = 625.0950 A Vtrans = 6.250950 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:55:36 Magnet Current Measurement: Imag = 625.0960 +- 0.0100 A 12:55:37 Magnet current ramping to 650.0000 A... 12:55:52 Magnet Current, Imag = 650.1670 A Vtrans = 6.501670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:55:54 Magnet Current, Imag = 650.1610 A Vtrans = 6.501610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:55:55 Magnet Current, Imag = 650.1580 A Vtrans = 6.501580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:55:57 Magnet Current, Imag = 650.1280 A Vtrans = 6.501280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:55:57 Magnet Current Measurement: Imag = 650.1535 +- 0.0151 A 12:55:57 Magnetic Field Measurement Measuring the magnet strength... 12:55:57 Integrated Voltage Measurement... 12:56:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021530715 Vs 12:56:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019398331 Vs 12:56:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021522298 Vs 12:56:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019401629 Vs 12:56:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021523793 Vs 12:57:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019372898 Vs 12:57:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021523285 Vs 12:57:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019397443 Vs 12:57:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020458799 +- 0.000006215 Vs 12:57:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020458799 +- 0.000006215 Vs BL = 2.04587991 +- 0.00062151 Tm 12:57:29 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.04588 0.00062 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.04588 0.00062 2.04588 0.00000 12:57:29 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.04588 0.00062 SL = 2.0458799 +- 0.0006215 Tm^2/m^n 12:57:29 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0458799 +- 0.0006215 Tm^2/m^n 12:57:31 Magnet Current, Imag = 650.1450 A Vtrans = 6.501450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:57:32 Magnet Current, Imag = 650.1440 A Vtrans = 6.501440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:57:34 Magnet Current, Imag = 650.1410 A Vtrans = 6.501410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:57:35 Magnet Current, Imag = 650.1390 A Vtrans = 6.501390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:57:35 Magnet Current Measurement: Imag = 650.1422 +- 0.0024 A 12:57:36 Magnet current ramping to 675.0000 A... 12:57:51 Magnet Current, Imag = 675.1020 A Vtrans = 6.751020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:57:53 Magnet Current, Imag = 675.1670 A Vtrans = 6.751670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:57:54 Magnet Current, Imag = 675.1640 A Vtrans = 6.751640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:57:56 Magnet Current, Imag = 675.1700 A Vtrans = 6.751700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:57:56 Magnet Current Measurement: Imag = 675.1507 +- 0.0282 A 12:57:56 Magnetic Field Measurement Measuring the magnet strength... 12:57:56 Integrated Voltage Measurement... 12:58:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.022186614 Vs 12:58:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020052344 Vs 12:58:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.022182293 Vs 12:58:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020057913 Vs 12:58:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.022176798 Vs 12:59:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020061168 Vs 12:59:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.022183916 Vs 12:59:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020038493 Vs 12:59:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021117442 +- 0.000003623 Vs 12:59:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021117442 +- 0.000003623 Vs BL = 2.11174425 +- 0.00036232 Tm 12:59:28 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.11174 0.00036 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.11174 0.00036 2.11174 0.00000 12:59:28 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.11174 0.00036 SL = 2.1117443 +- 0.0003623 Tm^2/m^n 12:59:28 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1117443 +- 0.0003623 Tm^2/m^n 12:59:30 Magnet Current, Imag = 675.1700 A Vtrans = 6.751700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:59:31 Magnet Current, Imag = 675.1610 A Vtrans = 6.751610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:59:33 Magnet Current, Imag = 675.1340 A Vtrans = 6.751340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:59:34 Magnet Current, Imag = 675.0720 A Vtrans = 6.750720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:59:34 Magnet Current Measurement: Imag = 675.1342 +- 0.0383 A 12:59:35 Magnet current ramping to 700.0000 A... 12:59:50 Magnet Current, Imag = 700.1600 A Vtrans = 7.001600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:59:52 Magnet Current, Imag = 700.1850 A Vtrans = 7.001850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:59:53 Magnet Current, Imag = 700.1600 A Vtrans = 7.001600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:59:55 Magnet Current, Imag = 700.2120 A Vtrans = 7.002120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:59:55 Magnet Current Measurement: Imag = 700.1792 +- 0.0215 A 12:59:55 Magnetic Field Measurement Measuring the magnet strength... 12:59:55 Integrated Voltage Measurement... 13:00:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.022797517 Vs 13:00:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020686579 Vs 13:00:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.022792323 Vs 13:00:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020676504 Vs 13:00:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.022794156 Vs 13:01:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020666789 Vs 13:01:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.022793746 Vs 13:01:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020664443 Vs 13:01:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021734007 +- 0.000005036 Vs 13:01:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021734007 +- 0.000005036 Vs BL = 2.17340072 +- 0.00050360 Tm 13:01:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.17340 0.00050 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.17340 0.00050 2.17340 0.00000 13:01:27 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.17340 0.00050 SL = 2.1734007 +- 0.0005036 Tm^2/m^n 13:01:27 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1734007 +- 0.0005036 Tm^2/m^n 13:01:28 Magnet Current, Imag = 700.1370 A Vtrans = 7.001370 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:01:30 Magnet Current, Imag = 700.1260 A Vtrans = 7.001260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:01:32 Magnet Current, Imag = 700.1640 A Vtrans = 7.001640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:01:33 Magnet Current, Imag = 700.1710 A Vtrans = 7.001710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:01:33 Magnet Current Measurement: Imag = 700.1495 +- 0.0186 A 13:01:33 Magnet current ramping to 650.0000 A... 13:01:56 Magnet Current, Imag = 650.1260 A Vtrans = 6.501260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:01:58 Magnet Current, Imag = 650.0640 A Vtrans = 6.500640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:02:00 Magnet Current, Imag = 650.0660 A Vtrans = 6.500660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:02:01 Magnet Current, Imag = 650.0760 A Vtrans = 6.500760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:02:01 Magnet Current Measurement: Imag = 650.0830 +- 0.0252 A 13:02:01 Magnetic Field Measurement Measuring the magnet strength... 13:02:01 Integrated Voltage Measurement... 13:02:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021606540 Vs 13:02:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019472945 Vs 13:02:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021615385 Vs 13:02:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019444169 Vs 13:02:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021595082 Vs 13:03:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019456903 Vs 13:03:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021591707 Vs 13:03:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019470996 Vs 13:03:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020531716 +- 0.000005027 Vs 13:03:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020531716 +- 0.000005027 Vs BL = 2.05317159 +- 0.00050269 Tm 13:03:33 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.05317 0.00050 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.05317 0.00050 2.05317 0.00000 13:03:33 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.05317 0.00050 SL = 2.0531716 +- 0.0005027 Tm^2/m^n 13:03:33 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0531716 +- 0.0005027 Tm^2/m^n 13:03:34 Magnet Current, Imag = 650.0960 A Vtrans = 6.500960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:03:36 Magnet Current, Imag = 650.0920 A Vtrans = 6.500920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:03:38 Magnet Current, Imag = 650.0790 A Vtrans = 6.500790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:03:39 Magnet Current, Imag = 650.1110 A Vtrans = 6.501110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:03:39 Magnet Current Measurement: Imag = 650.0945 +- 0.0114 A 13:03:40 Magnet current ramping to 600.0000 A... 13:04:03 Magnet Current, Imag = 600.0730 A Vtrans = 6.000730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:04:04 Magnet Current, Imag = 600.1010 A Vtrans = 6.001010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:04:06 Magnet Current, Imag = 600.1110 A Vtrans = 6.001110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:04:07 Magnet Current, Imag = 600.1020 A Vtrans = 6.001020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:04:07 Magnet Current Measurement: Imag = 600.0967 +- 0.0143 A 13:04:07 Magnetic Field Measurement Measuring the magnet strength... 13:04:07 Integrated Voltage Measurement... 13:04:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020169939 Vs 13:04:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018034721 Vs 13:04:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020178518 Vs 13:04:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018035267 Vs 13:05:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020162209 Vs 13:05:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018048294 Vs 13:05:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020157009 Vs 13:05:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018034022 Vs 13:05:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019102497 +- 0.000004350 Vs 13:05:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019102497 +- 0.000004350 Vs BL = 1.91024972 +- 0.00043496 Tm 13:05:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.91025 0.00043 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.91025 0.00043 1.91025 0.00000 13:05:45 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.91025 0.00043 SL = 1.9102497 +- 0.0004350 Tm^2/m^n 13:05:45 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9102497 +- 0.0004350 Tm^2/m^n 13:05:46 Magnet Current, Imag = 600.1070 A Vtrans = 6.001070 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:05:48 Magnet Current, Imag = 600.1200 A Vtrans = 6.001200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:05:50 Magnet Current, Imag = 600.0700 A Vtrans = 6.000700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:05:51 Magnet Current, Imag = 600.0690 A Vtrans = 6.000690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:05:51 Magnet Current Measurement: Imag = 600.0915 +- 0.0225 A 13:05:51 Magnet current ramping to 550.0000 A... 13:06:15 Magnet Current, Imag = 550.0570 A Vtrans = 5.500570 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:06:16 Magnet Current, Imag = 550.0760 A Vtrans = 5.500760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:06:18 Magnet Current, Imag = 550.0510 A Vtrans = 5.500510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:06:19 Magnet Current, Imag = 550.0680 A Vtrans = 5.500680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:06:19 Magnet Current Measurement: Imag = 550.0630 +- 0.0097 A 13:06:19 Magnetic Field Measurement Measuring the magnet strength... 13:06:20 Integrated Voltage Measurement... 13:06:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018617025 Vs 13:06:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016472369 Vs 13:07:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018601431 Vs 13:07:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016500677 Vs 13:07:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018612766 Vs 13:07:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016490905 Vs 13:07:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018614873 Vs 13:07:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016481829 Vs 13:07:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017548984 +- 0.000002793 Vs 13:07:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017548984 +- 0.000002793 Vs BL = 1.75489842 +- 0.00027925 Tm 13:08:00 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.75490 0.00028 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.75490 0.00028 1.75490 0.00000 13:08:00 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.75490 0.00028 SL = 1.7548984 +- 0.0002793 Tm^2/m^n 13:08:00 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7548984 +- 0.0002793 Tm^2/m^n 13:08:01 Magnet Current, Imag = 550.0830 A Vtrans = 5.500830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:03 Magnet Current, Imag = 550.0590 A Vtrans = 5.500590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:04 Magnet Current, Imag = 550.0880 A Vtrans = 5.500880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:06 Magnet Current, Imag = 550.0740 A Vtrans = 5.500740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:06 Magnet Current Measurement: Imag = 550.0760 +- 0.0110 A 13:08:06 Magnet current ramping to 500.0000 A... 13:08:29 Magnet Current, Imag = 500.0720 A Vtrans = 5.000720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:31 Magnet Current, Imag = 500.0740 A Vtrans = 5.000740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:33 Magnet Current, Imag = 500.0580 A Vtrans = 5.000580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:34 Magnet Current, Imag = 500.0150 A Vtrans = 5.000150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:34 Magnet Current Measurement: Imag = 500.0547 +- 0.0238 A 13:08:34 Magnetic Field Measurement Measuring the magnet strength... 13:08:35 Integrated Voltage Measurement... 13:08:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017044611 Vs 13:08:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014933936 Vs 13:09:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017020821 Vs 13:09:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014906377 Vs 13:09:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017031989 Vs 13:09:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014919596 Vs 13:09:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017025909 Vs 13:10:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014909106 Vs 13:10:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015974043 +- 0.000009834 Vs 13:10:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015974043 +- 0.000009834 Vs BL = 1.59740432 +- 0.00098339 Tm 13:10:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.59740 0.00098 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.59740 0.00098 1.59740 0.00000 13:10:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.59740 0.00098 SL = 1.5974043 +- 0.0009834 Tm^2/m^n 13:10:06 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5974043 +- 0.0009834 Tm^2/m^n 13:10:07 Magnet Current, Imag = 500.0440 A Vtrans = 5.000440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:09 Magnet Current, Imag = 500.0390 A Vtrans = 5.000390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:10 Magnet Current, Imag = 500.0460 A Vtrans = 5.000460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:12 Magnet Current, Imag = 500.0270 A Vtrans = 5.000270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:12 Magnet Current Measurement: Imag = 500.0390 +- 0.0074 A 13:10:12 Magnet current ramping to 450.0000 A... 13:10:35 Magnet Current, Imag = 450.0010 A Vtrans = 4.500010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:37 Magnet Current, Imag = 450.0270 A Vtrans = 4.500270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:39 Magnet Current, Imag = 450.0090 A Vtrans = 4.500090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:40 Magnet Current, Imag = 450.0070 A Vtrans = 4.500070 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:40 Magnet Current Measurement: Imag = 450.0110 +- 0.0097 A 13:10:41 Magnetic Field Measurement Measuring the magnet strength... 13:10:41 Integrated Voltage Measurement... 13:10:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015437237 Vs 13:11:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013318301 Vs 13:11:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015443257 Vs 13:11:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013327662 Vs 13:11:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015448634 Vs 13:11:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013312799 Vs 13:11:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015440625 Vs 13:12:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013323046 Vs 13:12:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014381445 +- 0.000002753 Vs 13:12:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014381445 +- 0.000002753 Vs BL = 1.43814452 +- 0.00027529 Tm 13:12:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43814 0.00028 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.43814 0.00028 1.43814 0.00000 13:12:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43814 0.00028 SL = 1.4381445 +- 0.0002753 Tm^2/m^n 13:12:12 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4381445 +- 0.0002753 Tm^2/m^n 13:12:14 Magnet Current, Imag = 449.9870 A Vtrans = 4.499870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:12:15 Magnet Current, Imag = 449.9910 A Vtrans = 4.499910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:12:17 Magnet Current, Imag = 449.9940 A Vtrans = 4.499940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:12:18 Magnet Current, Imag = 450.0170 A Vtrans = 4.500170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:12:18 Magnet Current Measurement: Imag = 449.9973 +- 0.0117 A 13:12:19 Magnet current ramping to 400.0000 A... 13:12:42 Magnet Current, Imag = 399.9900 A Vtrans = 3.999900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:12:43 Magnet Current, Imag = 399.9490 A Vtrans = 3.999490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:12:45 Magnet Current, Imag = 399.9500 A Vtrans = 3.999500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:12:46 Magnet Current, Imag = 399.9910 A Vtrans = 3.999910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:12:46 Magnet Current Measurement: Imag = 399.9700 +- 0.0205 A 13:12:47 Magnetic Field Measurement Measuring the magnet strength... 13:12:47 Integrated Voltage Measurement... 13:13:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013874836 Vs 13:13:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011734913 Vs 13:13:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013853281 Vs 13:13:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011726697 Vs 13:13:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013853535 Vs 13:13:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011704230 Vs 13:14:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013860544 Vs 13:14:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011734068 Vs 13:14:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012792763 +- 0.000009588 Vs 13:14:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012792763 +- 0.000009588 Vs BL = 1.27927629 +- 0.00095876 Tm 13:14:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.27928 0.00096 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.27928 0.00096 1.27928 0.00000 13:14:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.27928 0.00096 SL = 1.2792763 +- 0.0009588 Tm^2/m^n 13:14:18 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2792763 +- 0.0009588 Tm^2/m^n 13:14:20 Magnet Current, Imag = 399.9630 A Vtrans = 3.999630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:14:21 Magnet Current, Imag = 399.9630 A Vtrans = 3.999630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:14:23 Magnet Current, Imag = 399.9660 A Vtrans = 3.999660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:14:24 Magnet Current, Imag = 399.9810 A Vtrans = 3.999810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:14:24 Magnet Current Measurement: Imag = 399.9682 +- 0.0075 A 13:14:55 Magnet current ramping to 0.0000 A...