SLAC Magnetic Measurements Date: 04-15-2002 Time: 11:42:41 Project: spear3 Magnet Type: gdipole Magnet Name: 109D-039 Serial Number: Run Number: 13 Measurement Device: stretched wire Operator: sa Comment: BL vs. I, Trim Test Currents (A): -12.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 11:42:48 Initial Zero Current Measurement, Imag_zero = 0.0000 A 11:43:19 Magnet current ramping to -12.0000 A... 11:44:11 Magnet Current, Imag = -12.1049 A Vtrans = -0.121049 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:44:13 Magnet Current, Imag = -12.1047 A Vtrans = -0.121047 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:44:14 Magnet Current, Imag = -12.1044 A Vtrans = -0.121044 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:44:16 Magnet Current, Imag = -12.1040 A Vtrans = -0.121040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:44:16 Magnet Current Measurement: Imag = -12.1045 +- 0.0003 A 11:44:16 Magnetic Field Measurement Measuring the magnet strength... 11:44:16 Integrated Voltage Measurement... 11:44:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000462794 Vs 11:44:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000114997 Vs 11:44:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000463178 Vs 11:45:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000115854 Vs 11:45:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000462695 Vs 11:45:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000115211 Vs 11:45:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000462925 Vs 11:45:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000115740 Vs 11:45:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000289174 +- 0.000000259 Vs 11:45:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000289174 +- 0.000000259 Vs BL = -0.02891743 +- 0.00002590 Tm 11:45:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02892 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.02892 0.00003 -0.02892 0.00000 11:45:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02892 0.00003 SL = -0.0289174 +- 0.0000259 Tm^2/m^n 11:45:47 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0289174 +- 0.0000259 Tm^2/m^n 11:45:49 Magnet Current, Imag = -12.0949 A Vtrans = -0.120949 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:45:51 Magnet Current, Imag = -12.0948 A Vtrans = -0.120948 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:45:53 Magnet Current, Imag = -12.0947 A Vtrans = -0.120947 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:45:55 Magnet Current, Imag = -12.0946 A Vtrans = -0.120946 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:45:55 Magnet Current Measurement: Imag = -12.0947 +- 0.0001 A 11:45:55 Magnet current ramping to -10.0000 A... 11:46:11 Magnet Current, Imag = -10.0490 A Vtrans = -0.100490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:46:13 Magnet Current, Imag = -10.0490 A Vtrans = -0.100490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:46:15 Magnet Current, Imag = -10.0490 A Vtrans = -0.100490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:46:17 Magnet Current, Imag = -10.0490 A Vtrans = -0.100490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:46:17 Magnet Current Measurement: Imag = -10.0490 +- 0.0000 A 11:46:17 Magnetic Field Measurement Measuring the magnet strength... 11:46:17 Integrated Voltage Measurement... 11:46:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000411663 Vs 11:46:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000066806 Vs 11:46:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000409543 Vs 11:47:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000066773 Vs 11:47:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000410167 Vs 11:47:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000066501 Vs 11:47:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000409141 Vs 11:47:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000067522 Vs 11:47:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000238515 +- 0.000000422 Vs 11:47:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000238515 +- 0.000000422 Vs BL = -0.02385146 +- 0.00004218 Tm 11:47:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02385 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.02385 0.00004 -0.02385 0.00000 11:47:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02385 0.00004 SL = -0.0238515 +- 0.0000422 Tm^2/m^n 11:47:48 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0238515 +- 0.0000422 Tm^2/m^n 11:47:50 Magnet Current, Imag = -10.0488 A Vtrans = -0.100488 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:47:52 Magnet Current, Imag = -10.0488 A Vtrans = -0.100488 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:47:54 Magnet Current, Imag = -10.0487 A Vtrans = -0.100487 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:47:55 Magnet Current, Imag = -10.0487 A Vtrans = -0.100487 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:47:55 Magnet Current Measurement: Imag = -10.0487 +- 0.0000 A 11:47:56 Magnet current ramping to -8.0000 A... 11:48:12 Magnet Current, Imag = -8.0193 A Vtrans = -0.080193 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:48:13 Magnet Current, Imag = -8.0192 A Vtrans = -0.080192 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:48:15 Magnet Current, Imag = -8.0193 A Vtrans = -0.080194 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:48:17 Magnet Current, Imag = -8.0193 A Vtrans = -0.080193 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:48:17 Magnet Current Measurement: Imag = -8.0193 +- 0.0000 A 11:48:17 Magnetic Field Measurement Measuring the magnet strength... 11:48:17 Integrated Voltage Measurement... 11:48:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000358917 Vs 11:48:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000015145 Vs 11:48:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000359329 Vs 11:49:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000014592 Vs 11:49:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000358919 Vs 11:49:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000015184 Vs 11:49:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000360055 Vs 11:49:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000015268 Vs 11:49:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000187176 +- 0.000000282 Vs 11:49:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000187176 +- 0.000000282 Vs BL = -0.01871761 +- 0.00002822 Tm 11:49:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01872 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.01872 0.00003 -0.01872 0.00000 11:49:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01872 0.00003 SL = -0.0187176 +- 0.0000282 Tm^2/m^n 11:49:49 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0187176 +- 0.0000282 Tm^2/m^n 11:49:51 Magnet Current, Imag = -8.0206 A Vtrans = -0.080206 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:49:53 Magnet Current, Imag = -8.0205 A Vtrans = -0.080205 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:49:54 Magnet Current, Imag = -8.0206 A Vtrans = -0.080206 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:49:56 Magnet Current, Imag = -8.0206 A Vtrans = -0.080205 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:49:56 Magnet Current Measurement: Imag = -8.0206 +- 0.0000 A 11:49:56 Magnet current ramping to -6.0000 A... 11:50:12 Magnet Current, Imag = -5.9898 A Vtrans = -0.059898 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:50:14 Magnet Current, Imag = -5.9898 A Vtrans = -0.059898 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:50:16 Magnet Current, Imag = -5.9898 A Vtrans = -0.059898 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:50:18 Magnet Current, Imag = -5.9899 A Vtrans = -0.059899 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:50:18 Magnet Current Measurement: Imag = -5.9898 +- 0.0000 A 11:50:18 Magnetic Field Measurement Measuring the magnet strength... 11:50:18 Integrated Voltage Measurement... 11:50:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000305892 Vs 11:50:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000034427 Vs 11:50:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000305925 Vs 11:51:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000032680 Vs 11:51:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000305506 Vs 11:51:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000033119 Vs 11:51:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000304748 Vs 11:51:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000033241 Vs 11:51:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000136075 +- 0.000000365 Vs 11:51:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000136075 +- 0.000000365 Vs BL = -0.01360755 +- 0.00003655 Tm 11:51:50 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01361 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.01361 0.00004 -0.01361 0.00000 11:51:50 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01361 0.00004 SL = -0.0136075 +- 0.0000365 Tm^2/m^n 11:51:50 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0136075 +- 0.0000365 Tm^2/m^n 11:51:52 Magnet Current, Imag = -5.9909 A Vtrans = -0.059909 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:51:54 Magnet Current, Imag = -5.9910 A Vtrans = -0.059910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:51:56 Magnet Current, Imag = -5.9911 A Vtrans = -0.059911 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:51:58 Magnet Current, Imag = -5.9910 A Vtrans = -0.059910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:51:58 Magnet Current Measurement: Imag = -5.9910 +- 0.0000 A 11:51:58 Magnet current ramping to -4.0000 A... 11:52:14 Magnet Current, Imag = -3.9604 A Vtrans = -0.039604 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:52:16 Magnet Current, Imag = -3.9604 A Vtrans = -0.039604 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:52:18 Magnet Current, Imag = -3.9604 A Vtrans = -0.039604 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:52:20 Magnet Current, Imag = -3.9604 A Vtrans = -0.039604 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:52:20 Magnet Current Measurement: Imag = -3.9604 +- 0.0000 A 11:52:20 Magnetic Field Measurement Measuring the magnet strength... 11:52:20 Integrated Voltage Measurement... 11:52:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000254183 Vs 11:52:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000084903 Vs 11:52:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000253199 Vs 11:53:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000084368 Vs 11:53:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000253723 Vs 11:53:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000085316 Vs 11:53:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000254571 Vs 11:53:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000086221 Vs 11:53:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000084358 +- 0.000000187 Vs 11:53:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000084358 +- 0.000000187 Vs BL = -0.00843585 +- 0.00001875 Tm 11:53:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00844 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00844 0.00002 -0.00844 0.00000 11:53:51 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00844 0.00002 SL = -0.0084358 +- 0.0000187 Tm^2/m^n 11:53:51 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0084358 +- 0.0000187 Tm^2/m^n 11:53:53 Magnet Current, Imag = -3.9610 A Vtrans = -0.039610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:53:55 Magnet Current, Imag = -3.9611 A Vtrans = -0.039611 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:53:57 Magnet Current, Imag = -3.9611 A Vtrans = -0.039611 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:53:59 Magnet Current, Imag = -3.9611 A Vtrans = -0.039612 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:53:59 Magnet Current Measurement: Imag = -3.9611 +- 0.0000 A 11:53:59 Magnet current ramping to -2.0000 A... 11:54:15 Magnet Current, Imag = -1.9304 A Vtrans = -0.019304 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:54:17 Magnet Current, Imag = -1.9305 A Vtrans = -0.019305 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:54:19 Magnet Current, Imag = -1.9305 A Vtrans = -0.019305 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:54:20 Magnet Current, Imag = -1.9305 A Vtrans = -0.019305 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:54:20 Magnet Current Measurement: Imag = -1.9305 +- 0.0000 A 11:54:20 Magnetic Field Measurement Measuring the magnet strength... 11:54:21 Integrated Voltage Measurement... 11:54:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000203686 Vs 11:54:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000137421 Vs 11:54:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000202647 Vs 11:55:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000137437 Vs 11:55:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000203472 Vs 11:55:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000137387 Vs 11:55:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000203695 Vs 11:55:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000137167 Vs 11:55:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000033011 +- 0.000000247 Vs 11:55:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000033011 +- 0.000000247 Vs BL = -0.00330110 +- 0.00002474 Tm 11:55:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00330 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00330 0.00002 -0.00330 0.00000 11:55:51 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00330 0.00002 SL = -0.0033011 +- 0.0000247 Tm^2/m^n 11:55:51 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0033011 +- 0.0000247 Tm^2/m^n 11:55:53 Magnet Current, Imag = -1.9309 A Vtrans = -0.019309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:55:55 Magnet Current, Imag = -1.9309 A Vtrans = -0.019309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:55:57 Magnet Current, Imag = -1.9309 A Vtrans = -0.019309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:55:59 Magnet Current, Imag = -1.9309 A Vtrans = -0.019309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:55:59 Magnet Current Measurement: Imag = -1.9309 +- 0.0000 A 11:55:59 Magnet current ramping to 0.0000 A... 11:56:15 Magnet Current, Imag = 0.1018 A Vtrans = 0.001018 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:56:17 Magnet Current, Imag = 0.1018 A Vtrans = 0.001018 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:56:19 Magnet Current, Imag = 0.1017 A Vtrans = 0.001017 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:56:21 Magnet Current, Imag = 0.1017 A Vtrans = 0.001017 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:56:21 Magnet Current Measurement: Imag = 0.1017 +- 0.0000 A 11:56:21 Magnetic Field Measurement Measuring the magnet strength... 11:56:21 Integrated Voltage Measurement... 11:56:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000150084 Vs 11:56:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000189838 Vs 11:56:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000150924 Vs 11:57:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000189376 Vs 11:57:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000150653 Vs 11:57:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000190043 Vs 11:57:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000150631 Vs 11:57:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000188346 Vs 11:57:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000019414 +- 0.000000399 Vs 11:57:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000019414 +- 0.000000399 Vs BL = 0.00194137 +- 0.00003995 Tm 11:57:53 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00194 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00194 0.00004 0.00194 0.00000 11:57:53 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00194 0.00004 SL = 0.0019414 +- 0.0000399 Tm^2/m^n 11:57:53 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0019414 +- 0.0000399 Tm^2/m^n 11:57:55 Magnet Current, Imag = 0.1016 A Vtrans = 0.001016 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:57:57 Magnet Current, Imag = 0.1016 A Vtrans = 0.001016 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:57:59 Magnet Current, Imag = 0.1016 A Vtrans = 0.001016 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:58:01 Magnet Current, Imag = 0.1015 A Vtrans = 0.001015 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:58:01 Magnet Current Measurement: Imag = 0.1016 +- 0.0000 A 11:58:01 Magnet current ramping to 2.0000 A... 11:58:17 Magnet Current, Imag = 2.1338 A Vtrans = 0.021338 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:58:20 Magnet Current, Imag = 2.1337 A Vtrans = 0.021337 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:58:22 Magnet Current, Imag = 2.1337 A Vtrans = 0.021337 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:58:24 Magnet Current, Imag = 2.1337 A Vtrans = 0.021337 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:58:24 Magnet Current Measurement: Imag = 2.1337 +- 0.0000 A 11:58:24 Magnetic Field Measurement Measuring the magnet strength... 11:58:24 Integrated Voltage Measurement... 11:58:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000099953 Vs 11:58:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000241056 Vs 11:58:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000099884 Vs 11:59:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000240103 Vs 11:59:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000099519 Vs 11:59:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000240725 Vs 11:59:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000099538 Vs 11:59:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000241502 Vs 11:59:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000070562 +- 0.000000309 Vs 11:59:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000070562 +- 0.000000309 Vs BL = 0.00705615 +- 0.00003095 Tm 11:59:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00706 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00706 0.00003 0.00706 0.00000 11:59:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00706 0.00003 SL = 0.0070562 +- 0.0000309 Tm^2/m^n 11:59:55 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0070562 +- 0.0000309 Tm^2/m^n 11:59:57 Magnet Current, Imag = 2.1335 A Vtrans = 0.021335 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:59:59 Magnet Current, Imag = 2.1335 A Vtrans = 0.021335 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:00:01 Magnet Current, Imag = 2.1334 A Vtrans = 0.021334 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:00:03 Magnet Current, Imag = 2.1335 A Vtrans = 0.021335 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:00:03 Magnet Current Measurement: Imag = 2.1335 +- 0.0000 A 12:00:03 Magnet current ramping to 4.0000 A... 12:00:20 Magnet Current, Imag = 4.1652 A Vtrans = 0.041652 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:00:22 Magnet Current, Imag = 4.1651 A Vtrans = 0.041651 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:00:24 Magnet Current, Imag = 4.1650 A Vtrans = 0.041650 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:00:26 Magnet Current, Imag = 4.1650 A Vtrans = 0.041650 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:00:26 Magnet Current Measurement: Imag = 4.1651 +- 0.0001 A 12:00:26 Magnetic Field Measurement Measuring the magnet strength... 12:00:26 Integrated Voltage Measurement... 12:00:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000049355 Vs 12:00:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000293989 Vs 12:01:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000049125 Vs 12:01:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000293989 Vs 12:01:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000049794 Vs 12:01:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000294959 Vs 12:01:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000049781 Vs 12:01:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000294623 Vs 12:01:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000122438 +- 0.000000095 Vs 12:01:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000122438 +- 0.000000095 Vs BL = 0.01224380 +- 0.00000946 Tm 12:01:59 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.01224 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.01224 0.00001 0.01224 0.00000 12:01:59 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.01224 0.00001 SL = 0.0122438 +- 0.0000095 Tm^2/m^n 12:01:59 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0122438 +- 0.0000095 Tm^2/m^n 12:02:01 Magnet Current, Imag = 4.1644 A Vtrans = 0.041644 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:02:03 Magnet Current, Imag = 4.1645 A Vtrans = 0.041645 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:02:05 Magnet Current, Imag = 4.1645 A Vtrans = 0.041645 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:02:07 Magnet Current, Imag = 4.1644 A Vtrans = 0.041644 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:02:07 Magnet Current Measurement: Imag = 4.1644 +- 0.0000 A 12:02:07 Magnet current ramping to 6.0000 A... 12:02:23 Magnet Current, Imag = 6.1959 A Vtrans = 0.061959 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:02:25 Magnet Current, Imag = 6.1958 A Vtrans = 0.061958 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:02:27 Magnet Current, Imag = 6.1957 A Vtrans = 0.061957 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:02:29 Magnet Current, Imag = 6.1955 A Vtrans = 0.061955 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:02:29 Magnet Current Measurement: Imag = 6.1957 +- 0.0001 A 12:02:29 Magnetic Field Measurement Measuring the magnet strength... 12:02:29 Integrated Voltage Measurement... 12:02:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000002083 Vs 12:02:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000346261 Vs 12:03:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000002448 Vs 12:03:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000346187 Vs 12:03:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000001483 Vs 12:03:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000348021 Vs 12:03:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000001565 Vs 12:03:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000346900 Vs 12:03:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000174369 +- 0.000000227 Vs 12:03:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000174369 +- 0.000000227 Vs BL = 0.01743686 +- 0.00002273 Tm 12:04:00 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.01744 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.01744 0.00002 0.01744 0.00000 12:04:00 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.01744 0.00002 SL = 0.0174369 +- 0.0000227 Tm^2/m^n 12:04:00 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0174369 +- 0.0000227 Tm^2/m^n 12:04:02 Magnet Current, Imag = 6.1944 A Vtrans = 0.061944 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:04:04 Magnet Current, Imag = 6.1944 A Vtrans = 0.061944 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:04:05 Magnet Current, Imag = 6.1944 A Vtrans = 0.061944 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:04:07 Magnet Current, Imag = 6.1943 A Vtrans = 0.061943 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:04:07 Magnet Current Measurement: Imag = 6.1944 +- 0.0000 A 12:04:08 Magnet current ramping to 8.0000 A... 12:04:23 Magnet Current, Imag = 8.2252 A Vtrans = 0.082252 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:04:25 Magnet Current, Imag = 8.2250 A Vtrans = 0.082250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:04:27 Magnet Current, Imag = 8.2249 A Vtrans = 0.082249 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:04:29 Magnet Current, Imag = 8.2247 A Vtrans = 0.082247 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:04:29 Magnet Current Measurement: Imag = 8.2249 +- 0.0002 A 12:04:29 Magnetic Field Measurement Measuring the magnet strength... 12:04:29 Integrated Voltage Measurement... 12:04:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000052805 Vs 12:04:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000401134 Vs 12:05:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000050885 Vs 12:05:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000401643 Vs 12:05:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000052907 Vs 12:05:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000399977 Vs 12:05:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000054489 Vs 12:05:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000399111 Vs 12:05:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000226619 +- 0.000000280 Vs 12:05:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000226619 +- 0.000000280 Vs BL = 0.02266188 +- 0.00002795 Tm 12:06:00 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.02266 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.02266 0.00003 0.02266 0.00000 12:06:00 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.02266 0.00003 SL = 0.0226619 +- 0.0000280 Tm^2/m^n 12:06:00 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0226619 +- 0.0000280 Tm^2/m^n 12:06:02 Magnet Current, Imag = 8.2227 A Vtrans = 0.082227 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:06:04 Magnet Current, Imag = 8.2226 A Vtrans = 0.082226 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:06:06 Magnet Current, Imag = 8.2227 A Vtrans = 0.082227 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:06:08 Magnet Current, Imag = 8.2226 A Vtrans = 0.082227 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:06:08 Magnet Current Measurement: Imag = 8.2227 +- 0.0000 A 12:06:08 Magnet current ramping to 10.0000 A... 12:06:25 Magnet Current, Imag = 10.2517 A Vtrans = 0.102517 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:06:27 Magnet Current, Imag = 10.2514 A Vtrans = 0.102514 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:06:29 Magnet Current, Imag = 10.2512 A Vtrans = 0.102512 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:06:31 Magnet Current, Imag = 10.2509 A Vtrans = 0.102509 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:06:31 Magnet Current Measurement: Imag = 10.2513 +- 0.0003 A 12:06:31 Magnetic Field Measurement Measuring the magnet strength... 12:06:31 Integrated Voltage Measurement... 12:06:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000107203 Vs 12:06:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000451299 Vs 12:07:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000106139 Vs 12:07:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000450769 Vs 12:07:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000105675 Vs 12:07:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000450287 Vs 12:07:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000106553 Vs 12:07:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000450828 Vs 12:07:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000278594 +- 0.000000457 Vs 12:07:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000278594 +- 0.000000457 Vs BL = 0.02785942 +- 0.00004571 Tm 12:08:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.02786 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.02786 0.00005 0.02786 0.00000 12:08:02 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.02786 0.00005 SL = 0.0278594 +- 0.0000457 Tm^2/m^n 12:08:02 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0278594 +- 0.0000457 Tm^2/m^n 12:08:04 Magnet Current, Imag = 10.2480 A Vtrans = 0.102480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:08:06 Magnet Current, Imag = 10.2480 A Vtrans = 0.102480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:08:08 Magnet Current, Imag = 10.2480 A Vtrans = 0.102480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:08:09 Magnet Current, Imag = 10.2479 A Vtrans = 0.102480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:08:10 Magnet Current Measurement: Imag = 10.2480 +- 0.0000 A 12:08:10 Magnet current ramping to 12.0000 A... 12:08:26 Magnet Current, Imag = 12.2763 A Vtrans = 0.122763 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:08:28 Magnet Current, Imag = 12.2760 A Vtrans = 0.122760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:08:29 Magnet Current, Imag = 12.2758 A Vtrans = 0.122758 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:08:31 Magnet Current, Imag = 12.2755 A Vtrans = 0.122755 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:08:31 Magnet Current Measurement: Imag = 12.2759 +- 0.0003 A 12:08:31 Magnetic Field Measurement Measuring the magnet strength... 12:08:31 Integrated Voltage Measurement... 12:08:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000159135 Vs 12:08:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000501783 Vs 12:09:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000158821 Vs 12:09:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000502787 Vs 12:09:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000158063 Vs 12:09:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000501665 Vs 12:09:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000159583 Vs 12:09:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000501841 Vs 12:09:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000330460 +- 0.000000367 Vs 12:09:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000330460 +- 0.000000367 Vs BL = 0.03304597 +- 0.00003666 Tm 12:10:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.03305 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.03305 0.00004 0.03305 0.00000 12:10:02 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.03305 0.00004 SL = 0.0330460 +- 0.0000367 Tm^2/m^n 12:10:02 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0330460 +- 0.0000367 Tm^2/m^n 12:10:04 Magnet Current, Imag = 12.2714 A Vtrans = 0.122714 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:10:06 Magnet Current, Imag = 12.2714 A Vtrans = 0.122714 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:10:08 Magnet Current, Imag = 12.2713 A Vtrans = 0.122713 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:10:10 Magnet Current, Imag = 12.2713 A Vtrans = 0.122714 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:10:10 Magnet Current Measurement: Imag = 12.2714 +- 0.0000 A 12:10:40 Magnet current ramping to 0.0000 A...