SLAC Magnetic Measurements Date: 04-15-2002 Time: 10:13:52 Project: spear3 Magnet Type: gdipole Magnet Name: 109D-039 Serial Number: Run Number: 12 Measurement Device: stretched wire Operator: sa Comment: BL vs I, Mains Standardization: 1 cycles from 0.0 A to 770.0 A to 0.0 A Test Currents (A): 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 500.0 525.0 550.0 575.0 600.0 625.0 650.0 675.0 700.0 650.0 600.0 550.0 500.0 450.0 400.0 10:14:01 Initial Zero Current Measurement, Imag_zero = 0.0000 A 10:14:01 Magnet current ramping to 15.0000 A... 10:14:32 Magnet current ramping to 770.0000 A... 10:18:49 Magnet current ramping to 0.0000 A... 10:23:40 Magnet current ramping to 50.0000 A... 10:24:04 Magnet Current, Imag = 58.0174 A Vtrans = 0.580174 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:24:05 Magnet Current, Imag = 51.9147 A Vtrans = 0.519147 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:24:07 Magnet Current, Imag = 47.5126 A Vtrans = 0.475126 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:24:08 Magnet Current, Imag = 49.4598 A Vtrans = 0.494598 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:24:08 Magnet Current Measurement: Imag = 51.7261 +- 3.9530 A 10:24:08 Magnetic Field Measurement Measuring the magnet strength... 10:24:08 Integrated Voltage Measurement... 10:24:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001003619 Vs 10:24:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001409642 Vs 10:24:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001024956 Vs 10:24:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001404420 Vs 10:25:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001032047 Vs 10:25:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001405301 Vs 10:25:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001035735 Vs 10:25:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001402327 Vs 10:25:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001214756 +- 0.000004991 Vs 10:25:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001214756 +- 0.000004991 Vs BL = 0.12147558 +- 0.00049912 Tm 10:25:39 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.12148 0.00050 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.12148 0.00050 0.12148 0.00000 10:25:39 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.12148 0.00050 SL = 0.1214756 +- 0.0004991 Tm^2/m^n 10:25:40 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1214756 +- 0.0004991 Tm^2/m^n 10:25:41 Magnet Current, Imag = 49.7064 A Vtrans = 0.497064 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:25:42 Magnet Current, Imag = 49.7017 A Vtrans = 0.497017 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:25:44 Magnet Current, Imag = 49.7172 A Vtrans = 0.497172 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:25:45 Magnet Current, Imag = 49.7195 A Vtrans = 0.497195 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:25:45 Magnet Current Measurement: Imag = 49.7112 +- 0.0074 A 10:25:45 Magnet current ramping to 100.0000 A... 10:26:08 Magnet Current, Imag = 99.7502 A Vtrans = 0.997502 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:26:10 Magnet Current, Imag = 99.7462 A Vtrans = 0.997462 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:26:11 Magnet Current, Imag = 99.7375 A Vtrans = 0.997375 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:26:12 Magnet Current, Imag = 99.7686 A Vtrans = 0.997686 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:26:12 Magnet Current Measurement: Imag = 99.7506 +- 0.0113 A 10:26:13 Magnetic Field Measurement Measuring the magnet strength... 10:26:13 Integrated Voltage Measurement... 10:26:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002230400 Vs 10:26:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002598115 Vs 10:26:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002226657 Vs 10:26:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002602992 Vs 10:27:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002225025 Vs 10:27:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002604254 Vs 10:27:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002222421 Vs 10:27:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002603765 Vs 10:27:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002414204 +- 0.000000673 Vs 10:27:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.002414204 +- 0.000000673 Vs BL = 0.24142035 +- 0.00006730 Tm 10:27:44 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.24142 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.24142 0.00007 0.24142 0.00000 10:27:44 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.24142 0.00007 SL = 0.2414204 +- 0.0000673 Tm^2/m^n 10:27:44 Magnet Strength Measurement Harmonic Number = 1 SL = 0.2414204 +- 0.0000673 Tm^2/m^n 10:27:45 Magnet Current, Imag = 99.7733 A Vtrans = 0.997733 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:27:47 Magnet Current, Imag = 99.7689 A Vtrans = 0.997689 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:27:48 Magnet Current, Imag = 99.7516 A Vtrans = 0.997516 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:27:49 Magnet Current, Imag = 99.7477 A Vtrans = 0.997477 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:27:49 Magnet Current Measurement: Imag = 99.7604 +- 0.0109 A 10:27:49 Magnet current ramping to 150.0000 A... 10:28:12 Magnet Current, Imag = 149.7979 A Vtrans = 1.497979 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:28:14 Magnet Current, Imag = 149.7871 A Vtrans = 1.497871 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:28:15 Magnet Current, Imag = 149.8110 A Vtrans = 1.498110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:28:17 Magnet Current, Imag = 149.8050 A Vtrans = 1.498050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:28:17 Magnet Current Measurement: Imag = 149.8002 +- 0.0089 A 10:28:17 Magnetic Field Measurement Measuring the magnet strength... 10:28:17 Integrated Voltage Measurement... 10:28:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003441699 Vs 10:28:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003810721 Vs 10:28:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003431623 Vs 10:29:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003804135 Vs 10:29:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003426113 Vs 10:29:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003819483 Vs 10:29:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003430388 Vs 10:29:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003820399 Vs 10:29:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003623070 +- 0.000003251 Vs 10:29:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.003623070 +- 0.000003251 Vs BL = 0.36230700 +- 0.00032512 Tm 10:29:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.36231 0.00033 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.36231 0.00033 0.36231 0.00000 10:29:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.36231 0.00033 SL = 0.3623070 +- 0.0003251 Tm^2/m^n 10:29:48 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3623070 +- 0.0003251 Tm^2/m^n 10:29:50 Magnet Current, Imag = 149.7915 A Vtrans = 1.497915 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:29:51 Magnet Current, Imag = 149.8257 A Vtrans = 1.498257 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:29:52 Magnet Current, Imag = 149.7871 A Vtrans = 1.497871 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:29:54 Magnet Current, Imag = 149.8070 A Vtrans = 1.498070 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:29:54 Magnet Current Measurement: Imag = 149.8028 +- 0.0151 A 10:29:54 Magnet current ramping to 200.0000 A... 10:30:17 Magnet Current, Imag = 199.8140 A Vtrans = 1.998140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:30:18 Magnet Current, Imag = 199.7863 A Vtrans = 1.997863 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:30:20 Magnet Current, Imag = 199.7826 A Vtrans = 1.997826 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:30:21 Magnet Current, Imag = 199.8053 A Vtrans = 1.998053 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:30:21 Magnet Current Measurement: Imag = 199.7970 +- 0.0130 A 10:30:21 Magnetic Field Measurement Measuring the magnet strength... 10:30:21 Integrated Voltage Measurement... 10:30:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004645492 Vs 10:30:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005023565 Vs 10:30:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004648888 Vs 10:31:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005025064 Vs 10:31:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004647784 Vs 10:31:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005023801 Vs 10:31:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004650115 Vs 10:31:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005023240 Vs 10:31:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004835994 +- 0.000000951 Vs 10:31:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004835994 +- 0.000000951 Vs BL = 0.48359936 +- 0.00009513 Tm 10:31:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.48360 0.00010 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.48360 0.00010 0.48360 0.00000 10:31:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.48360 0.00010 SL = 0.4835994 +- 0.0000951 Tm^2/m^n 10:31:52 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4835994 +- 0.0000951 Tm^2/m^n 10:31:54 Magnet Current, Imag = 199.7930 A Vtrans = 1.997930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:31:55 Magnet Current, Imag = 199.7978 A Vtrans = 1.997978 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:31:57 Magnet Current, Imag = 199.8041 A Vtrans = 1.998041 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:31:58 Magnet Current, Imag = 199.7980 A Vtrans = 1.997980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:31:58 Magnet Current Measurement: Imag = 199.7982 +- 0.0039 A 10:31:58 Magnet current ramping to 250.0000 A... 10:32:21 Magnet Current, Imag = 249.8534 A Vtrans = 2.498534 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:32:22 Magnet Current, Imag = 249.8439 A Vtrans = 2.498439 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:32:24 Magnet Current, Imag = 249.8562 A Vtrans = 2.498562 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:32:25 Magnet Current, Imag = 249.8659 A Vtrans = 2.498659 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:32:25 Magnet Current Measurement: Imag = 249.8548 +- 0.0078 A 10:32:25 Magnetic Field Measurement Measuring the magnet strength... 10:32:25 Integrated Voltage Measurement... 10:32:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005864315 Vs 10:32:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006238153 Vs 10:33:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005855053 Vs 10:33:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006234652 Vs 10:33:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005854735 Vs 10:33:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006232621 Vs 10:33:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005865795 Vs 10:33:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006234561 Vs 10:33:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006047486 +- 0.000003268 Vs 10:33:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006047486 +- 0.000003268 Vs BL = 0.60474857 +- 0.00032685 Tm 10:33:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.60475 0.00033 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.60475 0.00033 0.60475 0.00000 10:33:56 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.60475 0.00033 SL = 0.6047486 +- 0.0003268 Tm^2/m^n 10:33:56 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6047486 +- 0.0003268 Tm^2/m^n 10:33:58 Magnet Current, Imag = 249.8285 A Vtrans = 2.498285 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:33:59 Magnet Current, Imag = 249.8390 A Vtrans = 2.498390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:34:01 Magnet Current, Imag = 249.8308 A Vtrans = 2.498308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:34:02 Magnet Current, Imag = 249.8490 A Vtrans = 2.498490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:34:02 Magnet Current Measurement: Imag = 249.8368 +- 0.0080 A 10:34:02 Magnet current ramping to 300.0000 A... 10:34:25 Magnet Current, Imag = 299.8779 A Vtrans = 2.998779 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:34:26 Magnet Current, Imag = 299.8943 A Vtrans = 2.998943 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:34:28 Magnet Current, Imag = 299.9154 A Vtrans = 2.999154 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:34:29 Magnet Current, Imag = 299.8877 A Vtrans = 2.998877 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:34:29 Magnet Current Measurement: Imag = 299.8938 +- 0.0138 A 10:34:30 Magnetic Field Measurement Measuring the magnet strength... 10:34:30 Integrated Voltage Measurement... 10:34:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007072713 Vs 10:34:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007449568 Vs 10:35:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007073183 Vs 10:35:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007448443 Vs 10:35:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007075835 Vs 10:35:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007453578 Vs 10:35:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007075409 Vs 10:35:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007453984 Vs 10:35:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007262839 +- 0.000001866 Vs 10:35:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.007262839 +- 0.000001866 Vs BL = 0.72628391 +- 0.00018662 Tm 10:36:01 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.72628 0.00019 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.72628 0.00019 0.72628 0.00000 10:36:01 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.72628 0.00019 SL = 0.7262839 +- 0.0001866 Tm^2/m^n 10:36:01 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7262839 +- 0.0001866 Tm^2/m^n 10:36:02 Magnet Current, Imag = 299.8801 A Vtrans = 2.998801 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:36:04 Magnet Current, Imag = 299.8812 A Vtrans = 2.998812 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:36:05 Magnet Current, Imag = 299.9029 A Vtrans = 2.999029 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:36:06 Magnet Current, Imag = 299.8969 A Vtrans = 2.998969 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:36:07 Magnet Current Measurement: Imag = 299.8903 +- 0.0099 A 10:36:07 Magnet current ramping to 350.0000 A... 10:36:30 Magnet Current, Imag = 349.9720 A Vtrans = 3.499720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:36:32 Magnet Current, Imag = 349.9030 A Vtrans = 3.499030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:36:34 Magnet Current, Imag = 349.9630 A Vtrans = 3.499630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:36:36 Magnet Current, Imag = 349.9640 A Vtrans = 3.499640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:36:36 Magnet Current Measurement: Imag = 349.9505 +- 0.0276 A 10:36:36 Magnetic Field Measurement Measuring the magnet strength... 10:36:36 Integrated Voltage Measurement... 10:36:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008289331 Vs 10:37:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008650329 Vs 10:37:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008277134 Vs 10:37:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008661201 Vs 10:37:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008285504 Vs 10:37:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008665161 Vs 10:37:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008276741 Vs 10:38:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008664868 Vs 10:38:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008471284 +- 0.000002409 Vs 10:38:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.008471284 +- 0.000002409 Vs BL = 0.84712837 +- 0.00024091 Tm 10:38:07 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.84713 0.00024 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.84713 0.00024 0.84713 0.00000 10:38:07 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.84713 0.00024 SL = 0.8471284 +- 0.0002409 Tm^2/m^n 10:38:07 Magnet Strength Measurement Harmonic Number = 1 SL = 0.8471284 +- 0.0002409 Tm^2/m^n 10:38:09 Magnet Current, Imag = 349.9400 A Vtrans = 3.499400 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:38:11 Magnet Current, Imag = 349.9240 A Vtrans = 3.499240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:38:13 Magnet Current, Imag = 349.9380 A Vtrans = 3.499380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:38:15 Magnet Current, Imag = 349.9360 A Vtrans = 3.499360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:38:15 Magnet Current Measurement: Imag = 349.9345 +- 0.0062 A 10:38:15 Magnet current ramping to 400.0000 A... 10:38:38 Magnet Current, Imag = 399.9530 A Vtrans = 3.999530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:38:40 Magnet Current, Imag = 399.9460 A Vtrans = 3.999460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:38:41 Magnet Current, Imag = 399.9470 A Vtrans = 3.999470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:38:43 Magnet Current, Imag = 399.9520 A Vtrans = 3.999520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:38:43 Magnet Current Measurement: Imag = 399.9495 +- 0.0030 A 10:38:43 Magnetic Field Measurement Measuring the magnet strength... 10:38:43 Integrated Voltage Measurement... 10:38:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009487333 Vs 10:39:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009868440 Vs 10:39:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009500671 Vs 10:39:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009874001 Vs 10:39:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009491980 Vs 10:39:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009865346 Vs 10:40:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009490770 Vs 10:40:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009870767 Vs 10:40:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009681163 +- 0.000003716 Vs 10:40:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009681163 +- 0.000003716 Vs BL = 0.96811633 +- 0.00037163 Tm 10:40:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.96812 0.00037 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.96812 0.00037 0.96812 0.00000 10:40:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.96812 0.00037 SL = 0.9681163 +- 0.0003716 Tm^2/m^n 10:40:14 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9681163 +- 0.0003716 Tm^2/m^n 10:40:16 Magnet Current, Imag = 399.9530 A Vtrans = 3.999530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:40:17 Magnet Current, Imag = 399.9630 A Vtrans = 3.999630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:40:19 Magnet Current, Imag = 399.9610 A Vtrans = 3.999610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:40:20 Magnet Current, Imag = 399.9570 A Vtrans = 3.999570 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:40:20 Magnet Current Measurement: Imag = 399.9585 +- 0.0038 A 10:40:20 Magnet current ramping to 450.0000 A... 10:40:43 Magnet Current, Imag = 450.0000 A Vtrans = 4.500000 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:40:45 Magnet Current, Imag = 450.0030 A Vtrans = 4.500030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:40:46 Magnet Current, Imag = 450.0150 A Vtrans = 4.500150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:40:48 Magnet Current, Imag = 450.0090 A Vtrans = 4.500090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:40:48 Magnet Current Measurement: Imag = 450.0067 +- 0.0058 A 10:40:48 Magnetic Field Measurement Measuring the magnet strength... 10:40:48 Integrated Voltage Measurement... 10:41:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010699297 Vs 10:41:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011081959 Vs 10:41:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010689648 Vs 10:41:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011077382 Vs 10:41:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010686591 Vs 10:41:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011083983 Vs 10:42:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010696315 Vs 10:42:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011079902 Vs 10:42:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010886885 +- 0.000002712 Vs 10:42:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.010886885 +- 0.000002712 Vs BL = 1.08868845 +- 0.00027118 Tm 10:42:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.08869 0.00027 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.08869 0.00027 1.08869 0.00000 10:42:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.08869 0.00027 SL = 1.0886885 +- 0.0002712 Tm^2/m^n 10:42:19 Magnet Strength Measurement Harmonic Number = 1 SL = 1.0886885 +- 0.0002712 Tm^2/m^n 10:42:21 Magnet Current, Imag = 450.0100 A Vtrans = 4.500100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:42:22 Magnet Current, Imag = 449.9920 A Vtrans = 4.499920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:42:24 Magnet Current, Imag = 449.9800 A Vtrans = 4.499800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:42:26 Magnet Current, Imag = 450.0050 A Vtrans = 4.500050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:42:26 Magnet Current Measurement: Imag = 449.9968 +- 0.0117 A 10:42:26 Magnet current ramping to 500.0000 A... 10:42:49 Magnet Current, Imag = 500.0690 A Vtrans = 5.000690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:42:50 Magnet Current, Imag = 500.0830 A Vtrans = 5.000830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:42:52 Magnet Current, Imag = 500.0610 A Vtrans = 5.000610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:42:53 Magnet Current, Imag = 500.0510 A Vtrans = 5.000510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:42:53 Magnet Current Measurement: Imag = 500.0660 +- 0.0117 A 10:42:53 Magnetic Field Measurement Measuring the magnet strength... 10:42:53 Integrated Voltage Measurement... 10:43:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011905215 Vs 10:43:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012279946 Vs 10:43:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011910160 Vs 10:43:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012273225 Vs 10:43:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011907638 Vs 10:44:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012278665 Vs 10:44:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011907699 Vs 10:44:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012286711 Vs 10:44:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012093657 +- 0.000002113 Vs 10:44:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012093657 +- 0.000002113 Vs BL = 1.20936574 +- 0.00021131 Tm 10:44:25 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.20937 0.00021 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.20937 0.00021 1.20937 0.00000 10:44:25 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.20937 0.00021 SL = 1.2093657 +- 0.0002113 Tm^2/m^n 10:44:25 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2093657 +- 0.0002113 Tm^2/m^n 10:44:26 Magnet Current, Imag = 500.0460 A Vtrans = 5.000460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:44:28 Magnet Current, Imag = 500.0480 A Vtrans = 5.000480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:44:29 Magnet Current, Imag = 500.0560 A Vtrans = 5.000560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:44:31 Magnet Current, Imag = 500.0740 A Vtrans = 5.000740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:44:31 Magnet Current Measurement: Imag = 500.0560 +- 0.0110 A 10:44:31 Magnet current ramping to 525.0000 A... 10:44:47 Magnet Current, Imag = 525.0710 A Vtrans = 5.250710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:44:48 Magnet Current, Imag = 525.1020 A Vtrans = 5.251020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:44:50 Magnet Current, Imag = 525.1080 A Vtrans = 5.251080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:44:51 Magnet Current, Imag = 525.0990 A Vtrans = 5.250990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:44:51 Magnet Current Measurement: Imag = 525.0950 +- 0.0142 A 10:44:52 Magnetic Field Measurement Measuring the magnet strength... 10:44:52 Integrated Voltage Measurement... 10:45:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012501492 Vs 10:45:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012885593 Vs 10:45:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012493741 Vs 10:45:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012878944 Vs 10:45:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012503818 Vs 10:45:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012881539 Vs 10:46:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012495305 Vs 10:46:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012888889 Vs 10:46:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012691165 +- 0.000002831 Vs 10:46:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012691165 +- 0.000002831 Vs BL = 1.26911653 +- 0.00028315 Tm 10:46:23 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.26912 0.00028 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.26912 0.00028 1.26912 0.00000 10:46:23 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.26912 0.00028 SL = 1.2691165 +- 0.0002831 Tm^2/m^n 10:46:23 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2691165 +- 0.0002831 Tm^2/m^n 10:46:24 Magnet Current, Imag = 525.1050 A Vtrans = 5.251050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:46:26 Magnet Current, Imag = 525.0680 A Vtrans = 5.250680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:46:28 Magnet Current, Imag = 525.0720 A Vtrans = 5.250720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:46:29 Magnet Current, Imag = 525.0730 A Vtrans = 5.250730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:46:29 Magnet Current Measurement: Imag = 525.0795 +- 0.0148 A 10:46:29 Magnet current ramping to 550.0000 A... 10:46:45 Magnet Current, Imag = 550.0580 A Vtrans = 5.500580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:46:46 Magnet Current, Imag = 550.0650 A Vtrans = 5.500650 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:46:48 Magnet Current, Imag = 550.0700 A Vtrans = 5.500700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:46:50 Magnet Current, Imag = 550.0520 A Vtrans = 5.500520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:46:50 Magnet Current Measurement: Imag = 550.0612 +- 0.0068 A 10:46:50 Magnetic Field Measurement Measuring the magnet strength... 10:46:50 Integrated Voltage Measurement... 10:47:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013098207 Vs 10:47:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013477703 Vs 10:47:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013086927 Vs 10:47:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013462820 Vs 10:47:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013094939 Vs 10:47:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013475212 Vs 10:48:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013094479 Vs 10:48:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013474443 Vs 10:48:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013283091 +- 0.000004925 Vs 10:48:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.013283091 +- 0.000004925 Vs BL = 1.32830913 +- 0.00049246 Tm 10:48:21 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.32831 0.00049 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.32831 0.00049 1.32831 0.00000 10:48:21 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.32831 0.00049 SL = 1.3283091 +- 0.0004925 Tm^2/m^n 10:48:21 Magnet Strength Measurement Harmonic Number = 1 SL = 1.3283091 +- 0.0004925 Tm^2/m^n 10:48:23 Magnet Current, Imag = 550.0360 A Vtrans = 5.500360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:48:24 Magnet Current, Imag = 550.0470 A Vtrans = 5.500470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:48:26 Magnet Current, Imag = 550.0480 A Vtrans = 5.500480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:48:27 Magnet Current, Imag = 550.0390 A Vtrans = 5.500390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:48:27 Magnet Current Measurement: Imag = 550.0425 +- 0.0051 A 10:48:27 Magnet current ramping to 575.0000 A... 10:48:43 Magnet Current, Imag = 575.0940 A Vtrans = 5.750940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:48:45 Magnet Current, Imag = 575.0860 A Vtrans = 5.750860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:48:46 Magnet Current, Imag = 575.0840 A Vtrans = 5.750840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:48:48 Magnet Current, Imag = 575.0720 A Vtrans = 5.750720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:48:48 Magnet Current Measurement: Imag = 575.0840 +- 0.0079 A 10:48:48 Magnetic Field Measurement Measuring the magnet strength... 10:48:48 Integrated Voltage Measurement... 10:49:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013673480 Vs 10:49:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014066187 Vs 10:49:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013676809 Vs 10:49:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014052306 Vs 10:49:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013680253 Vs 10:49:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014069353 Vs 10:50:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013663752 Vs 10:50:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014059143 Vs 10:50:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013867660 +- 0.000005098 Vs 10:50:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.013867660 +- 0.000005098 Vs BL = 1.38676604 +- 0.00050983 Tm 10:50:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.38677 0.00051 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.38677 0.00051 1.38677 0.00000 10:50:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.38677 0.00051 SL = 1.3867660 +- 0.0005098 Tm^2/m^n 10:50:19 Magnet Strength Measurement Harmonic Number = 1 SL = 1.3867660 +- 0.0005098 Tm^2/m^n 10:50:21 Magnet Current, Imag = 575.1040 A Vtrans = 5.751040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:22 Magnet Current, Imag = 575.0940 A Vtrans = 5.750940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:24 Magnet Current, Imag = 575.0860 A Vtrans = 5.750860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:25 Magnet Current, Imag = 575.1020 A Vtrans = 5.751020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:25 Magnet Current Measurement: Imag = 575.0965 +- 0.0071 A 10:50:25 Magnet current ramping to 600.0000 A... 10:50:41 Magnet Current, Imag = 600.1280 A Vtrans = 6.001280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:43 Magnet Current, Imag = 600.1130 A Vtrans = 6.001130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:44 Magnet Current, Imag = 600.1000 A Vtrans = 6.001000 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:46 Magnet Current, Imag = 600.1030 A Vtrans = 6.001030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:46 Magnet Current Measurement: Imag = 600.1110 +- 0.0109 A 10:50:46 Magnetic Field Measurement Measuring the magnet strength... 10:50:46 Integrated Voltage Measurement... 10:50:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014261227 Vs 10:51:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014622400 Vs 10:51:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014254248 Vs 10:51:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014635699 Vs 10:51:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014254684 Vs 10:51:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014635003 Vs 10:52:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014253901 Vs 10:52:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014625337 Vs 10:52:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014442813 +- 0.000002235 Vs 10:52:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014442813 +- 0.000002235 Vs BL = 1.44428125 +- 0.00022354 Tm 10:52:17 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.44428 0.00022 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.44428 0.00022 1.44428 0.00000 10:52:17 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.44428 0.00022 SL = 1.4442812 +- 0.0002235 Tm^2/m^n 10:52:17 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4442812 +- 0.0002235 Tm^2/m^n 10:52:19 Magnet Current, Imag = 600.1170 A Vtrans = 6.001170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:52:20 Magnet Current, Imag = 600.1490 A Vtrans = 6.001490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:52:22 Magnet Current, Imag = 600.1400 A Vtrans = 6.001400 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:52:23 Magnet Current, Imag = 600.1250 A Vtrans = 6.001250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:52:23 Magnet Current Measurement: Imag = 600.1327 +- 0.0125 A 10:52:24 Magnet current ramping to 625.0000 A... 10:52:39 Magnet Current, Imag = 625.1510 A Vtrans = 6.251510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:52:41 Magnet Current, Imag = 625.1010 A Vtrans = 6.251010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:52:42 Magnet Current, Imag = 625.1190 A Vtrans = 6.251190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:52:44 Magnet Current, Imag = 625.1470 A Vtrans = 6.251470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:52:44 Magnet Current Measurement: Imag = 625.1295 +- 0.0206 A 10:52:44 Magnetic Field Measurement Measuring the magnet strength... 10:52:44 Integrated Voltage Measurement... 10:52:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014805215 Vs 10:53:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015193371 Vs 10:53:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014815321 Vs 10:53:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015206891 Vs 10:53:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014807027 Vs 10:53:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015196839 Vs 10:54:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014805865 Vs 10:54:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015195304 Vs 10:54:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015003229 +- 0.000004643 Vs 10:54:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015003229 +- 0.000004643 Vs BL = 1.50032292 +- 0.00046426 Tm 10:54:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.50032 0.00046 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.50032 0.00046 1.50032 0.00000 10:54:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.50032 0.00046 SL = 1.5003229 +- 0.0004643 Tm^2/m^n 10:54:15 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5003229 +- 0.0004643 Tm^2/m^n 10:54:17 Magnet Current, Imag = 625.1530 A Vtrans = 6.251530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:18 Magnet Current, Imag = 625.1720 A Vtrans = 6.251720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:20 Magnet Current, Imag = 625.1590 A Vtrans = 6.251590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:22 Magnet Current, Imag = 625.1750 A Vtrans = 6.251750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:22 Magnet Current Measurement: Imag = 625.1647 +- 0.0091 A 10:54:22 Magnet current ramping to 650.0000 A... 10:54:37 Magnet Current, Imag = 650.1640 A Vtrans = 6.501640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:39 Magnet Current, Imag = 650.1780 A Vtrans = 6.501780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:40 Magnet Current, Imag = 650.1920 A Vtrans = 6.501920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:42 Magnet Current, Imag = 650.1870 A Vtrans = 6.501870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:42 Magnet Current Measurement: Imag = 650.1803 +- 0.0106 A 10:54:42 Magnetic Field Measurement Measuring the magnet strength... 10:54:42 Integrated Voltage Measurement... 10:54:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015333085 Vs 10:55:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015725379 Vs 10:55:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015339833 Vs 10:55:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015729919 Vs 10:55:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015339753 Vs 10:55:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015725414 Vs 10:55:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015337392 Vs 10:56:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015724679 Vs 10:56:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015531932 +- 0.000002073 Vs 10:56:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015531932 +- 0.000002073 Vs BL = 1.55319320 +- 0.00020728 Tm 10:56:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.55319 0.00021 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.55319 0.00021 1.55319 0.00000 10:56:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.55319 0.00021 SL = 1.5531932 +- 0.0002073 Tm^2/m^n 10:56:13 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5531932 +- 0.0002073 Tm^2/m^n 10:56:15 Magnet Current, Imag = 650.2010 A Vtrans = 6.502010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:16 Magnet Current, Imag = 650.1990 A Vtrans = 6.501990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:18 Magnet Current, Imag = 650.1770 A Vtrans = 6.501770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:20 Magnet Current, Imag = 650.1630 A Vtrans = 6.501630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:20 Magnet Current Measurement: Imag = 650.1850 +- 0.0158 A 10:56:20 Magnet current ramping to 675.0000 A... 10:56:35 Magnet Current, Imag = 675.1840 A Vtrans = 6.751840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:37 Magnet Current, Imag = 675.1960 A Vtrans = 6.751960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:38 Magnet Current, Imag = 675.1930 A Vtrans = 6.751930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:40 Magnet Current, Imag = 675.2470 A Vtrans = 6.752470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:40 Magnet Current Measurement: Imag = 675.2050 +- 0.0246 A 10:56:40 Magnetic Field Measurement Measuring the magnet strength... 10:56:40 Integrated Voltage Measurement... 10:56:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015839631 Vs 10:57:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016224529 Vs 10:57:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015847809 Vs 10:57:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016233124 Vs 10:57:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015842294 Vs 10:57:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016225579 Vs 10:57:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015842617 Vs 10:58:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016225986 Vs 10:58:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016035196 +- 0.000003157 Vs 10:58:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016035196 +- 0.000003157 Vs BL = 1.60351960 +- 0.00031573 Tm 10:58:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.60352 0.00032 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.60352 0.00032 1.60352 0.00000 10:58:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.60352 0.00032 SL = 1.6035196 +- 0.0003157 Tm^2/m^n 10:58:12 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6035196 +- 0.0003157 Tm^2/m^n 10:58:13 Magnet Current, Imag = 675.2010 A Vtrans = 6.752010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:15 Magnet Current, Imag = 675.2020 A Vtrans = 6.752020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:16 Magnet Current, Imag = 675.2020 A Vtrans = 6.752020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:18 Magnet Current, Imag = 675.2010 A Vtrans = 6.752010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:18 Magnet Current Measurement: Imag = 675.2015 +- 0.0005 A 10:58:18 Magnet current ramping to 700.0000 A... 10:58:34 Magnet Current, Imag = 700.2340 A Vtrans = 7.002340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:35 Magnet Current, Imag = 700.2370 A Vtrans = 7.002370 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:37 Magnet Current, Imag = 700.2430 A Vtrans = 7.002430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:38 Magnet Current, Imag = 700.2300 A Vtrans = 7.002300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:38 Magnet Current Measurement: Imag = 700.2360 +- 0.0047 A 10:58:38 Magnetic Field Measurement Measuring the magnet strength... 10:58:38 Integrated Voltage Measurement... 10:58:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016302543 Vs 10:59:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016691559 Vs 10:59:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016305959 Vs 10:59:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016695381 Vs 10:59:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016307739 Vs 10:59:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016700071 Vs 10:59:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016306618 Vs 11:00:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016694391 Vs 11:00:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016500532 +- 0.000002425 Vs 11:00:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016500532 +- 0.000002425 Vs BL = 1.65005325 +- 0.00024247 Tm 11:00:10 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.65005 0.00024 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.65005 0.00024 1.65005 0.00000 11:00:10 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.65005 0.00024 SL = 1.6500532 +- 0.0002425 Tm^2/m^n 11:00:10 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6500532 +- 0.0002425 Tm^2/m^n 11:00:11 Magnet Current, Imag = 700.2300 A Vtrans = 7.002300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:13 Magnet Current, Imag = 700.2200 A Vtrans = 7.002200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:14 Magnet Current, Imag = 700.2400 A Vtrans = 7.002400 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:16 Magnet Current, Imag = 700.2430 A Vtrans = 7.002430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:16 Magnet Current Measurement: Imag = 700.2332 +- 0.0090 A 11:00:16 Magnet current ramping to 650.0000 A... 11:00:39 Magnet Current, Imag = 650.1870 A Vtrans = 6.501870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:41 Magnet Current, Imag = 650.2160 A Vtrans = 6.502160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:42 Magnet Current, Imag = 650.1930 A Vtrans = 6.501930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:44 Magnet Current, Imag = 650.1800 A Vtrans = 6.501800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:44 Magnet Current Measurement: Imag = 650.1940 +- 0.0135 A 11:00:44 Magnetic Field Measurement Measuring the magnet strength... 11:00:44 Integrated Voltage Measurement... 11:00:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015402883 Vs 11:01:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015788300 Vs 11:01:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015397765 Vs 11:01:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015789519 Vs 11:01:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015398200 Vs 11:01:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015789289 Vs 11:02:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015396397 Vs 11:02:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015788384 Vs 11:02:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015593842 +- 0.000001142 Vs 11:02:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015593842 +- 0.000001142 Vs BL = 1.55938422 +- 0.00011422 Tm 11:02:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.55938 0.00011 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.55938 0.00011 1.55938 0.00000 11:02:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.55938 0.00011 SL = 1.5593842 +- 0.0001142 Tm^2/m^n 11:02:15 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5593842 +- 0.0001142 Tm^2/m^n 11:02:17 Magnet Current, Imag = 650.1580 A Vtrans = 6.501580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:18 Magnet Current, Imag = 650.1690 A Vtrans = 6.501690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:20 Magnet Current, Imag = 650.1870 A Vtrans = 6.501870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:21 Magnet Current, Imag = 650.1500 A Vtrans = 6.501500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:21 Magnet Current Measurement: Imag = 650.1660 +- 0.0139 A 11:02:22 Magnet current ramping to 600.0000 A... 11:02:45 Magnet Current, Imag = 600.0740 A Vtrans = 6.000740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:46 Magnet Current, Imag = 600.1040 A Vtrans = 6.001040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:48 Magnet Current, Imag = 600.1120 A Vtrans = 6.001120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:49 Magnet Current, Imag = 600.1380 A Vtrans = 6.001380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:49 Magnet Current Measurement: Imag = 600.1070 +- 0.0228 A 11:02:49 Magnetic Field Measurement Measuring the magnet strength... 11:02:49 Integrated Voltage Measurement... 11:03:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014314555 Vs 11:03:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014703787 Vs 11:03:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014310939 Vs 11:03:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014698189 Vs 11:03:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014313636 Vs 11:03:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014704245 Vs 11:04:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014315593 Vs 11:04:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014700992 Vs 11:04:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014507742 +- 0.000001863 Vs 11:04:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014507742 +- 0.000001863 Vs BL = 1.45077420 +- 0.00018627 Tm 11:04:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.45077 0.00019 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.45077 0.00019 1.45077 0.00000 11:04:21 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.45077 0.00019 SL = 1.4507742 +- 0.0001863 Tm^2/m^n 11:04:21 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4507742 +- 0.0001863 Tm^2/m^n 11:04:22 Magnet Current, Imag = 600.1010 A Vtrans = 6.001010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:24 Magnet Current, Imag = 600.1030 A Vtrans = 6.001030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:25 Magnet Current, Imag = 600.1180 A Vtrans = 6.001180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:27 Magnet Current, Imag = 600.1040 A Vtrans = 6.001040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:27 Magnet Current Measurement: Imag = 600.1065 +- 0.0067 A 11:04:27 Magnet current ramping to 550.0000 A... 11:04:50 Magnet Current, Imag = 550.0410 A Vtrans = 5.500410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:52 Magnet Current, Imag = 550.0280 A Vtrans = 5.500280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:53 Magnet Current, Imag = 550.0280 A Vtrans = 5.500280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:55 Magnet Current, Imag = 550.0490 A Vtrans = 5.500490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:55 Magnet Current Measurement: Imag = 550.0365 +- 0.0090 A 11:04:55 Magnetic Field Measurement Measuring the magnet strength... 11:04:55 Integrated Voltage Measurement... 11:05:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013144829 Vs 11:05:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013534527 Vs 11:05:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013143402 Vs 11:05:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013531756 Vs 11:05:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013151428 Vs 11:06:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013540635 Vs 11:06:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013140117 Vs 11:06:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013529390 Vs 11:06:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013339511 +- 0.000004151 Vs 11:06:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.013339511 +- 0.000004151 Vs BL = 1.33395105 +- 0.00041508 Tm 11:06:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.33395 0.00042 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.33395 0.00042 1.33395 0.00000 11:06:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.33395 0.00042 SL = 1.3339511 +- 0.0004151 Tm^2/m^n 11:06:26 Magnet Strength Measurement Harmonic Number = 1 SL = 1.3339511 +- 0.0004151 Tm^2/m^n 11:06:28 Magnet Current, Imag = 550.0600 A Vtrans = 5.500600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:30 Magnet Current, Imag = 550.0590 A Vtrans = 5.500590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:31 Magnet Current, Imag = 550.0740 A Vtrans = 5.500740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:33 Magnet Current, Imag = 550.0930 A Vtrans = 5.500930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:33 Magnet Current Measurement: Imag = 550.0715 +- 0.0138 A 11:06:33 Magnet current ramping to 500.0000 A... 11:06:56 Magnet Current, Imag = 500.0710 A Vtrans = 5.000710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:57 Magnet Current, Imag = 500.0780 A Vtrans = 5.000780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:59 Magnet Current, Imag = 500.0460 A Vtrans = 5.000460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:07:00 Magnet Current, Imag = 500.0510 A Vtrans = 5.000510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:07:01 Magnet Current Measurement: Imag = 500.0615 +- 0.0134 A 11:07:01 Magnetic Field Measurement Measuring the magnet strength... 11:07:01 Integrated Voltage Measurement... 11:07:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011953211 Vs 11:07:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012331907 Vs 11:07:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011945268 Vs 11:07:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012335715 Vs 11:07:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011951123 Vs 11:08:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012328772 Vs 11:08:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011942851 Vs 11:08:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012332072 Vs 11:08:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012140115 +- 0.000001815 Vs 11:08:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012140115 +- 0.000001815 Vs BL = 1.21401147 +- 0.00018154 Tm 11:08:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.21401 0.00018 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.21401 0.00018 1.21401 0.00000 11:08:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.21401 0.00018 SL = 1.2140115 +- 0.0001815 Tm^2/m^n 11:08:32 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2140115 +- 0.0001815 Tm^2/m^n 11:08:33 Magnet Current, Imag = 500.0840 A Vtrans = 5.000840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:08:35 Magnet Current, Imag = 500.0590 A Vtrans = 5.000590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:08:37 Magnet Current, Imag = 500.0300 A Vtrans = 5.000300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:08:38 Magnet Current, Imag = 500.0120 A Vtrans = 5.000120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:08:38 Magnet Current Measurement: Imag = 500.0462 +- 0.0275 A 11:08:38 Magnet current ramping to 450.0000 A... 11:09:01 Magnet Current, Imag = 449.9670 A Vtrans = 4.499670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:09:03 Magnet Current, Imag = 449.9650 A Vtrans = 4.499650 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:09:04 Magnet Current, Imag = 449.9700 A Vtrans = 4.499700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:09:06 Magnet Current, Imag = 449.9520 A Vtrans = 4.499520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:09:06 Magnet Current Measurement: Imag = 449.9635 +- 0.0069 A 11:09:06 Magnetic Field Measurement Measuring the magnet strength... 11:09:06 Integrated Voltage Measurement... 11:09:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010734972 Vs 11:09:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011131255 Vs 11:09:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010737765 Vs 11:09:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011128138 Vs 11:10:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010737271 Vs 11:10:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011125476 Vs 11:10:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010746839 Vs 11:10:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011126839 Vs 11:10:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010933570 +- 0.000002006 Vs 11:10:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.010933570 +- 0.000002006 Vs BL = 1.09335695 +- 0.00020064 Tm 11:10:37 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.09336 0.00020 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.09336 0.00020 1.09336 0.00000 11:10:37 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.09336 0.00020 SL = 1.0933569 +- 0.0002006 Tm^2/m^n 11:10:37 Magnet Strength Measurement Harmonic Number = 1 SL = 1.0933569 +- 0.0002006 Tm^2/m^n 11:10:39 Magnet Current, Imag = 449.9620 A Vtrans = 4.499620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:10:40 Magnet Current, Imag = 449.9760 A Vtrans = 4.499760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:10:42 Magnet Current, Imag = 449.9750 A Vtrans = 4.499750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:10:44 Magnet Current, Imag = 449.9770 A Vtrans = 4.499770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:10:44 Magnet Current Measurement: Imag = 449.9725 +- 0.0061 A 11:10:44 Magnet current ramping to 400.0000 A... 11:11:07 Magnet Current, Imag = 399.9250 A Vtrans = 3.999250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:11:08 Magnet Current, Imag = 399.9250 A Vtrans = 3.999250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:11:10 Magnet Current, Imag = 399.9200 A Vtrans = 3.999200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:11:11 Magnet Current, Imag = 399.9210 A Vtrans = 3.999210 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:11:11 Magnet Current Measurement: Imag = 399.9227 +- 0.0023 A 11:11:11 Magnetic Field Measurement Measuring the magnet strength... 11:11:11 Integrated Voltage Measurement... 11:11:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009526882 Vs 11:11:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009919676 Vs 11:11:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009524613 Vs 11:11:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009930415 Vs 11:12:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009533004 Vs 11:12:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009928039 Vs 11:12:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009536431 Vs 11:12:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009916107 Vs 11:12:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009726896 +- 0.000002598 Vs 11:12:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009726896 +- 0.000002598 Vs BL = 0.97268958 +- 0.00025981 Tm 11:12:43 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.97269 0.00026 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.97269 0.00026 0.97269 0.00000 11:12:43 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.97269 0.00026 SL = 0.9726896 +- 0.0002598 Tm^2/m^n 11:12:43 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9726896 +- 0.0002598 Tm^2/m^n 11:12:44 Magnet Current, Imag = 399.9330 A Vtrans = 3.999330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:12:46 Magnet Current, Imag = 399.9500 A Vtrans = 3.999500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:12:47 Magnet Current, Imag = 399.9490 A Vtrans = 3.999490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:12:49 Magnet Current, Imag = 399.9410 A Vtrans = 3.999410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:12:49 Magnet Current Measurement: Imag = 399.9432 +- 0.0069 A 11:13:19 Magnet current ramping to 0.0000 A...