SLAC Magnetic Measurements Date: 04-12-2002 Time: 16:18:44 Project: spear3 Magnet Type: gdipole Magnet Name: 109D-039 Serial Number: Run Number: 10 Measurement Device: stretched wire Operator: sa Comment: BL vs. I, Mains *** Run failed, Do Not Use ** -sa Standardization: 1 cycles from 0.0 A to 770.0 A to 0.0 A Test Currents (A): 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 500.0 525.0 550.0 575.0 600.0 625.0 650.0 675.0 700.0 650.0 600.0 550.0 500.0 450.0 400.0 16:19:07 Initial Zero Current Measurement, Imag_zero = 0.0000 A 16:19:07 Magnet current ramping to 15.0000 A... 16:19:38 Magnet current ramping to 770.0000 A... 16:23:53 Magnet current ramping to 0.0000 A... 16:28:42 Magnet current ramping to 50.0000 A... 16:29:05 Magnet Current, Imag = 51.6683 A Vtrans = 0.516683 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:29:06 Magnet Current, Imag = 42.7853 A Vtrans = 0.427853 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:29:08 Magnet Current, Imag = 50.2853 A Vtrans = 0.502853 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:29:09 Magnet Current, Imag = 50.9830 A Vtrans = 0.509830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:29:09 Magnet Current Measurement: Imag = 48.9305 +- 3.5815 A 16:29:09 Magnetic Field Measurement Measuring the magnet strength... 16:29:09 Integrated Voltage Measurement... 16:29:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001064297 Vs 16:29:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001403685 Vs 16:29:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001015036 Vs 16:29:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001400186 Vs 16:30:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001017303 Vs 16:30:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001398601 Vs 16:30:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001019369 Vs 16:30:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001402724 Vs 16:30:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001215150 +- 0.000010960 Vs 16:30:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001215150 +- 0.000010960 Vs BL = 0.12151500 +- 0.00109599 Tm 16:30:40 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.12151 0.00110 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.12151 0.00110 0.12151 0.00000 16:30:40 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.12151 0.00110 SL = 0.1215150 +- 0.0010960 Tm^2/m^n 16:30:40 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1215150 +- 0.0010960 Tm^2/m^n 16:30:41 Magnet Current, Imag = 49.5408 A Vtrans = 0.495408 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:30:43 Magnet Current, Imag = 49.5201 A Vtrans = 0.495201 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:30:44 Magnet Current, Imag = 49.5440 A Vtrans = 0.495440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:30:46 Magnet Current, Imag = 49.5085 A Vtrans = 0.495085 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:30:46 Magnet Current Measurement: Imag = 49.5283 +- 0.0147 A 16:30:46 Magnet current ramping to 100.0000 A... 16:31:08 Magnet Current, Imag = 99.6057 A Vtrans = 0.996057 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:31:10 Magnet Current, Imag = 99.5912 A Vtrans = 0.995912 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:31:11 Magnet Current, Imag = 99.5774 A Vtrans = 0.995774 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:31:13 Magnet Current, Imag = 99.5897 A Vtrans = 0.995897 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:31:13 Magnet Current Measurement: Imag = 99.5910 +- 0.0100 A 16:31:13 Magnetic Field Measurement Measuring the magnet strength... 16:31:13 Integrated Voltage Measurement... 16:31:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002218011 Vs 16:31:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002606688 Vs 16:31:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002215689 Vs 16:31:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002595231 Vs 16:32:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002207646 Vs 16:32:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002593451 Vs 16:32:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002213459 Vs 16:32:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002603723 Vs 16:32:40 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002406737 +- 0.000004326 Vs 16:32:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.002406737 +- 0.000004326 Vs BL = 0.24067372 +- 0.00043264 Tm 16:32:43 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.24067 0.00043 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.24067 0.00043 0.24067 0.00000 16:32:43 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.24067 0.00043 SL = 0.2406737 +- 0.0004326 Tm^2/m^n 16:32:43 Magnet Strength Measurement Harmonic Number = 1 SL = 0.2406737 +- 0.0004326 Tm^2/m^n 16:32:45 Magnet Current, Imag = 99.5974 A Vtrans = 0.995974 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:32:46 Magnet Current, Imag = 99.5932 A Vtrans = 0.995932 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:32:48 Magnet Current, Imag = 99.5668 A Vtrans = 0.995668 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:32:49 Magnet Current, Imag = 99.6010 A Vtrans = 0.996010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:32:49 Magnet Current Measurement: Imag = 99.5896 +- 0.0134 A 16:32:49 Magnet current ramping to 150.0000 A... 16:33:12 Magnet Current, Imag = 149.6208 A Vtrans = 1.496208 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:13 Magnet Current, Imag = 149.6595 A Vtrans = 1.496595 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:15 Magnet Current, Imag = 149.6884 A Vtrans = 1.496884 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:16 Magnet Current, Imag = 149.6624 A Vtrans = 1.496624 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:16 Magnet Current Measurement: Imag = 149.6578 +- 0.0241 A 16:33:16 Magnetic Field Measurement Measuring the magnet strength... 16:33:16 Integrated Voltage Measurement... 16:33:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003429140 Vs 16:33:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003820587 Vs 16:33:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003427390 Vs 16:34:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003807527 Vs 16:34:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003430240 Vs 16:34:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003813042 Vs 16:34:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003422433 Vs 16:34:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003809851 Vs 16:34:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003620026 +- 0.000003453 Vs 16:34:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.003620026 +- 0.000003453 Vs BL = 0.36200261 +- 0.00034529 Tm 16:34:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.36200 0.00035 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.36200 0.00035 0.36200 0.00000 16:34:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.36200 0.00035 SL = 0.3620026 +- 0.0003453 Tm^2/m^n 16:34:47 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3620026 +- 0.0003453 Tm^2/m^n 16:34:49 Magnet Current, Imag = 149.6513 A Vtrans = 1.496513 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:34:50 Magnet Current, Imag = 149.6518 A Vtrans = 1.496518 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:34:52 Magnet Current, Imag = 149.6557 A Vtrans = 1.496557 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:34:53 Magnet Current, Imag = 149.6698 A Vtrans = 1.496698 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:34:53 Magnet Current Measurement: Imag = 149.6572 +- 0.0075 A 16:34:53 Magnet current ramping to 200.0000 A... 16:35:16 Magnet Current, Imag = 199.6749 A Vtrans = 1.996749 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:17 Magnet Current, Imag = 199.6734 A Vtrans = 1.996734 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:19 Magnet Current, Imag = 199.6670 A Vtrans = 1.996670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:20 Magnet Current, Imag = 199.6815 A Vtrans = 1.996815 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:20 Magnet Current Measurement: Imag = 199.6742 +- 0.0052 A 16:35:20 Magnetic Field Measurement Measuring the magnet strength... 16:35:20 Integrated Voltage Measurement... 16:35:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004638093 Vs 16:35:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005028259 Vs 16:35:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004639320 Vs 16:36:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005026913 Vs 16:36:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004650925 Vs 16:36:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005026303 Vs 16:36:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004638175 Vs 16:36:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005024265 Vs 16:36:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004834032 +- 0.000002760 Vs 16:36:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004834032 +- 0.000002760 Vs BL = 0.48340318 +- 0.00027600 Tm 16:36:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.48340 0.00028 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.48340 0.00028 0.48340 0.00000 16:36:51 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.48340 0.00028 SL = 0.4834032 +- 0.0002760 Tm^2/m^n 16:36:51 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4834032 +- 0.0002760 Tm^2/m^n 16:36:52 Magnet Current, Imag = 199.6690 A Vtrans = 1.996690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:36:54 Magnet Current, Imag = 199.6686 A Vtrans = 1.996686 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:36:55 Magnet Current, Imag = 199.6603 A Vtrans = 1.996603 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:36:57 Magnet Current, Imag = 199.6577 A Vtrans = 1.996577 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:36:57 Magnet Current Measurement: Imag = 199.6639 +- 0.0050 A 16:36:57 Magnet current ramping to 250.0000 A... 16:37:20 Magnet Current, Imag = 249.7470 A Vtrans = 2.497470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:37:21 Magnet Current, Imag = 249.7434 A Vtrans = 2.497434 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:37:23 Magnet Current, Imag = 249.7137 A Vtrans = 2.497137 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:37:24 Magnet Current, Imag = 249.7318 A Vtrans = 2.497318 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:37:24 Magnet Current Measurement: Imag = 249.7340 +- 0.0130 A 16:37:24 Magnetic Field Measurement Measuring the magnet strength... 16:37:24 Integrated Voltage Measurement... 16:37:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005848947 Vs 16:37:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006243325 Vs 16:37:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005851008 Vs 16:38:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006239846 Vs 16:38:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005847389 Vs 16:38:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006239335 Vs 16:38:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005849528 Vs 16:38:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006239434 Vs 16:38:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006044851 +- 0.000001041 Vs 16:38:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006044851 +- 0.000001041 Vs BL = 0.60448513 +- 0.00010413 Tm 16:38:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.60449 0.00010 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.60449 0.00010 0.60449 0.00000 16:38:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.60449 0.00010 SL = 0.6044851 +- 0.0001041 Tm^2/m^n 16:38:55 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6044851 +- 0.0001041 Tm^2/m^n 16:38:57 Magnet Current, Imag = 249.7133 A Vtrans = 2.497133 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:38:58 Magnet Current, Imag = 249.7150 A Vtrans = 2.497150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:39:00 Magnet Current, Imag = 249.7264 A Vtrans = 2.497264 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:39:01 Magnet Current, Imag = 249.7494 A Vtrans = 2.497494 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:39:01 Magnet Current Measurement: Imag = 249.7260 +- 0.0144 A 16:39:01 Magnet current ramping to 300.0000 A... 16:39:24 Magnet Current, Imag = 299.7876 A Vtrans = 2.997876 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:39:25 Magnet Current, Imag = 299.7903 A Vtrans = 2.997903 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:39:27 Magnet Current, Imag = 299.7833 A Vtrans = 2.997833 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:39:28 Magnet Current, Imag = 299.7866 A Vtrans = 2.997866 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:39:28 Magnet Current Measurement: Imag = 299.7869 +- 0.0025 A 16:39:28 Magnetic Field Measurement Measuring the magnet strength... 16:39:28 Integrated Voltage Measurement... 16:39:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007061924 Vs 16:39:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007460259 Vs 16:40:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007053143 Vs 16:40:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007450808 Vs 16:40:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007067440 Vs 16:40:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007454568 Vs 16:40:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007059549 Vs 16:40:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007457773 Vs 16:40:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007258183 +- 0.000003714 Vs 16:40:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.007258183 +- 0.000003714 Vs BL = 0.72581831 +- 0.00037141 Tm 16:40:59 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.72582 0.00037 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.72582 0.00037 0.72582 0.00000 16:40:59 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.72582 0.00037 SL = 0.7258183 +- 0.0003714 Tm^2/m^n 16:40:59 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7258183 +- 0.0003714 Tm^2/m^n 16:41:00 Magnet Current, Imag = 299.7997 A Vtrans = 2.997997 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:41:02 Magnet Current, Imag = 299.8020 A Vtrans = 2.998020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:41:03 Magnet Current, Imag = 299.7979 A Vtrans = 2.997979 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:41:05 Magnet Current, Imag = 299.7932 A Vtrans = 2.997932 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:41:05 Magnet Current Measurement: Imag = 299.7982 +- 0.0032 A 16:41:05 Magnet current ramping to 350.0000 A... 16:41:28 Magnet Current, Imag = 349.8830 A Vtrans = 3.498830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:41:30 Magnet Current, Imag = 349.8920 A Vtrans = 3.498920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:41:32 Magnet Current, Imag = 349.8830 A Vtrans = 3.498830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:41:34 Magnet Current, Imag = 349.8770 A Vtrans = 3.498770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:41:34 Magnet Current Measurement: Imag = 349.8837 +- 0.0054 A 16:41:34 Magnetic Field Measurement Measuring the magnet strength... 16:41:34 Integrated Voltage Measurement... 16:41:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008272297 Vs 16:41:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008673155 Vs 16:42:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008272002 Vs 16:42:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008669081 Vs 16:42:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008274191 Vs 16:42:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008661101 Vs 16:42:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008276487 Vs 16:43:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008660583 Vs 16:43:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008469862 +- 0.000001958 Vs 16:43:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.008469862 +- 0.000001958 Vs BL = 0.84698620 +- 0.00019580 Tm 16:43:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.84699 0.00020 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.84699 0.00020 0.84699 0.00000 16:43:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.84699 0.00020 SL = 0.8469862 +- 0.0001958 Tm^2/m^n 16:43:05 Magnet Strength Measurement Harmonic Number = 1 SL = 0.8469862 +- 0.0001958 Tm^2/m^n 16:43:07 Magnet Current, Imag = 349.8670 A Vtrans = 3.498670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:43:09 Magnet Current, Imag = 349.9040 A Vtrans = 3.499040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:43:11 Magnet Current, Imag = 349.8710 A Vtrans = 3.498710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:43:13 Magnet Current, Imag = 349.8770 A Vtrans = 3.498770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:43:13 Magnet Current Measurement: Imag = 349.8797 +- 0.0144 A 16:43:13 Magnet current ramping to 400.0000 A... 16:43:36 Magnet Current, Imag = 399.8820 A Vtrans = 3.998820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:43:38 Magnet Current, Imag = 399.8850 A Vtrans = 3.998850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:43:39 Magnet Current, Imag = 399.9150 A Vtrans = 3.999150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:43:41 Magnet Current, Imag = 399.8920 A Vtrans = 3.998920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:43:41 Magnet Current Measurement: Imag = 399.8935 +- 0.0129 A 16:43:41 Magnetic Field Measurement Measuring the magnet strength... 16:43:41 Integrated Voltage Measurement... 16:43:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009483704 Vs 16:44:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009868363 Vs 16:44:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009486998 Vs 16:44:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009869478 Vs 16:44:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009487600 Vs 16:44:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009865893 Vs 16:44:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009482585 Vs 16:45:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009873912 Vs 16:45:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009677317 +- 0.000000960 Vs 16:45:08 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009677317 +- 0.000000960 Vs BL = 0.96773167 +- 0.00009604 Tm 16:45:11 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.96773 0.00010 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.96773 0.00010 0.96773 0.00000 16:45:11 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.96773 0.00010 SL = 0.9677317 +- 0.0000960 Tm^2/m^n 16:45:11 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9677317 +- 0.0000960 Tm^2/m^n 16:45:13 Magnet Current, Imag = 399.8760 A Vtrans = 3.998760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:45:15 Magnet Current, Imag = 399.8990 A Vtrans = 3.998990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:45:16 Magnet Current, Imag = 399.8980 A Vtrans = 3.998980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:45:18 Magnet Current, Imag = 399.9030 A Vtrans = 3.999030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:45:18 Magnet Current Measurement: Imag = 399.8940 +- 0.0106 A 16:45:18 Magnet current ramping to 450.0000 A... 16:45:41 Magnet Current, Imag = 449.9640 A Vtrans = 4.499640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:45:42 Magnet Current, Imag = 449.9670 A Vtrans = 4.499670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:45:44 Magnet Current, Imag = 449.9650 A Vtrans = 4.499650 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:45:45 Magnet Current, Imag = 449.9670 A Vtrans = 4.499670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:45:45 Magnet Current Measurement: Imag = 449.9657 +- 0.0013 A 16:45:46 Magnetic Field Measurement Measuring the magnet strength... 16:45:46 Integrated Voltage Measurement... 16:45:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010689612 Vs 16:46:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011083933 Vs 16:46:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010695470 Vs 16:46:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011084983 Vs 16:46:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010687767 Vs 16:46:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011084499 Vs 16:47:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010692413 Vs 16:47:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011081702 Vs 16:47:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010887547 +- 0.000001582 Vs 16:47:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.010887547 +- 0.000001582 Vs BL = 1.08875474 +- 0.00015825 Tm 16:47:16 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.08875 0.00016 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.08875 0.00016 1.08875 0.00000 16:47:16 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.08875 0.00016 SL = 1.0887547 +- 0.0001582 Tm^2/m^n 16:47:17 Magnet Strength Measurement Harmonic Number = 1 SL = 1.0887547 +- 0.0001582 Tm^2/m^n 16:47:18 Magnet Current, Imag = 449.9860 A Vtrans = 4.499860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:20 Magnet Current, Imag = 449.9810 A Vtrans = 4.499810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:21 Magnet Current, Imag = 449.9790 A Vtrans = 4.499790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:23 Magnet Current, Imag = 449.9560 A Vtrans = 4.499560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:23 Magnet Current Measurement: Imag = 449.9755 +- 0.0115 A 16:47:23 Magnet current ramping to 500.0000 A... 16:47:46 Magnet Current, Imag = 500.0370 A Vtrans = 5.000370 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:47 Magnet Current, Imag = 500.0590 A Vtrans = 5.000590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:49 Magnet Current, Imag = 500.0470 A Vtrans = 5.000470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:50 Magnet Current, Imag = 500.0510 A Vtrans = 5.000510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:51 Magnet Current Measurement: Imag = 500.0485 +- 0.0079 A 16:47:51 Magnetic Field Measurement Measuring the magnet strength... 16:47:51 Integrated Voltage Measurement... 16:48:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011892501 Vs 16:48:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012291153 Vs 16:48:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011888101 Vs 16:48:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012290210 Vs 16:48:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011894261 Vs 16:48:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012284005 Vs 16:49:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008424129 Vs 16:49:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012299327 Vs 16:49:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011657961 +- 0.000748381 Vs 16:49:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.011657961 +- 0.000748381 Vs BL = 1.16579607 +- 0.07483813 Tm 16:49:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.16580 0.07484 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.16580 0.07484 1.16580 0.00000 16:49:27 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.16580 0.07484 SL = 1.1657961 +- 0.0748381 Tm^2/m^n 16:49:28 Magnet Strength Measurement Harmonic Number = 1 SL = 1.1657961 +- 0.0748381 Tm^2/m^n 16:49:29 Magnet Current, Imag = 500.0540 A Vtrans = 5.000540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:49:31 Magnet Current, Imag = 500.0180 A Vtrans = 5.000180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:49:32 Magnet Current, Imag = 500.0300 A Vtrans = 5.000300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:49:34 Magnet Current, Imag = 500.0120 A Vtrans = 5.000120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:49:34 Magnet Current Measurement: Imag = 500.0285 +- 0.0161 A 16:49:34 Magnet current ramping to 525.0000 A... 16:49:49 Magnet Current, Imag = 525.0860 A Vtrans = 5.250860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:49:51 Magnet Current, Imag = 525.0820 A Vtrans = 5.250820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:49:53 Magnet Current, Imag = 525.0860 A Vtrans = 5.250860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:49:54 Magnet Current, Imag = 525.0790 A Vtrans = 5.250790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:49:54 Magnet Current Measurement: Imag = 525.0832 +- 0.0029 A 16:49:54 Magnetic Field Measurement Measuring the magnet strength... 16:49:54 Integrated Voltage Measurement... 16:50:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012493821 Vs 16:50:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012883801 Vs 16:50:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012488419 Vs 16:50:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012890517 Vs