SLAC Magnetic Measurements Date: 04-10-2002 Time: 13:41:34 Project: spear3 Magnet Type: gdipole Magnet Name: 109D-038 Serial Number: Run Number: 13 Measurement Device: stretched wire Operator: sa Comment: BL vs. I, trim Test Currents (A): -12.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 13:41:40 Initial Zero Current Measurement, Imag_zero = 0.0000 A 13:42:11 Magnet current ramping to -12.0000 A... 13:43:01 Magnet Current, Imag = -12.0930 A Vtrans = -0.120930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:43:03 Magnet Current, Imag = -12.0926 A Vtrans = -0.120926 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:43:05 Magnet Current, Imag = -12.0922 A Vtrans = -0.120923 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:43:07 Magnet Current, Imag = -12.0921 A Vtrans = -0.120921 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:43:07 Magnet Current Measurement: Imag = -12.0925 +- 0.0003 A 13:43:07 Magnetic Field Measurement Measuring the magnet strength... 13:43:07 Integrated Voltage Measurement... 13:43:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000379414 Vs 13:43:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000197302 Vs 13:43:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000379466 Vs 13:43:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000198149 Vs 13:44:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000379533 Vs 13:44:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000197839 Vs 13:44:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000378928 Vs 13:44:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000199499 Vs 13:44:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000288766 +- 0.000000306 Vs 13:44:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000288766 +- 0.000000306 Vs BL = -0.02887662 +- 0.00003062 Tm 13:44:37 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02888 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.02888 0.00003 -0.02888 0.00000 13:44:37 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02888 0.00003 SL = -0.0288766 +- 0.0000306 Tm^2/m^n 13:44:37 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0288766 +- 0.0000306 Tm^2/m^n 13:44:39 Magnet Current, Imag = -12.0829 A Vtrans = -0.120829 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:44:41 Magnet Current, Imag = -12.0829 A Vtrans = -0.120829 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:44:43 Magnet Current, Imag = -12.0828 A Vtrans = -0.120828 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:44:45 Magnet Current, Imag = -12.0827 A Vtrans = -0.120827 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:44:45 Magnet Current Measurement: Imag = -12.0828 +- 0.0001 A 13:44:45 Magnet current ramping to -10.0000 A... 13:45:01 Magnet Current, Imag = -10.0370 A Vtrans = -0.100370 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:45:03 Magnet Current, Imag = -10.0371 A Vtrans = -0.100371 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:45:05 Magnet Current, Imag = -10.0370 A Vtrans = -0.100370 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:45:07 Magnet Current, Imag = -10.0370 A Vtrans = -0.100370 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:45:07 Magnet Current Measurement: Imag = -10.0370 +- 0.0000 A 13:45:07 Magnetic Field Measurement Measuring the magnet strength... 13:45:07 Integrated Voltage Measurement... 13:45:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000326800 Vs 13:45:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000147581 Vs 13:45:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000326801 Vs 13:45:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000148225 Vs 13:46:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000326709 Vs 13:46:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000148061 Vs 13:46:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000326761 Vs 13:46:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000148493 Vs 13:46:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000237429 +- 0.000000162 Vs 13:46:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000237429 +- 0.000000162 Vs BL = -0.02374291 +- 0.00001621 Tm 13:46:37 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02374 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.02374 0.00002 -0.02374 0.00000 13:46:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02374 0.00002 SL = -0.0237429 +- 0.0000162 Tm^2/m^n 13:46:38 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0237429 +- 0.0000162 Tm^2/m^n 13:46:39 Magnet Current, Imag = -10.0369 A Vtrans = -0.100369 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:46:41 Magnet Current, Imag = -10.0369 A Vtrans = -0.100369 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:46:43 Magnet Current, Imag = -10.0369 A Vtrans = -0.100369 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:46:45 Magnet Current, Imag = -10.0369 A Vtrans = -0.100369 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:46:45 Magnet Current Measurement: Imag = -10.0369 +- 0.0000 A 13:46:45 Magnet current ramping to -8.0000 A... 13:47:01 Magnet Current, Imag = -8.0074 A Vtrans = -0.080074 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:47:03 Magnet Current, Imag = -8.0075 A Vtrans = -0.080075 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:47:06 Magnet Current, Imag = -8.0075 A Vtrans = -0.080075 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:47:08 Magnet Current, Imag = -8.0076 A Vtrans = -0.080076 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:47:08 Magnet Current Measurement: Imag = -8.0075 +- 0.0001 A 13:47:08 Magnetic Field Measurement Measuring the magnet strength... 13:47:08 Integrated Voltage Measurement... 13:47:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000276375 Vs 13:47:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000097897 Vs 13:47:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000276402 Vs 13:47:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000098394 Vs 13:48:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000275414 Vs 13:48:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000098306 Vs 13:48:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000275654 Vs 13:48:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000098219 Vs 13:48:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000187083 +- 0.000000208 Vs 13:48:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000187083 +- 0.000000208 Vs BL = -0.01870826 +- 0.00002081 Tm 13:48:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01871 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.01871 0.00002 -0.01871 0.00000 13:48:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01871 0.00002 SL = -0.0187083 +- 0.0000208 Tm^2/m^n 13:48:38 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0187083 +- 0.0000208 Tm^2/m^n 13:48:40 Magnet Current, Imag = -8.0086 A Vtrans = -0.080086 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:48:42 Magnet Current, Imag = -8.0086 A Vtrans = -0.080086 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:48:44 Magnet Current, Imag = -8.0086 A Vtrans = -0.080086 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:48:46 Magnet Current, Imag = -8.0086 A Vtrans = -0.080086 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:48:46 Magnet Current Measurement: Imag = -8.0086 +- 0.0000 A 13:48:46 Magnet current ramping to -6.0000 A... 13:49:02 Magnet Current, Imag = -5.9780 A Vtrans = -0.059780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:49:03 Magnet Current, Imag = -5.9781 A Vtrans = -0.059781 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:49:05 Magnet Current, Imag = -5.9780 A Vtrans = -0.059780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:49:07 Magnet Current, Imag = -5.9781 A Vtrans = -0.059781 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:49:07 Magnet Current Measurement: Imag = -5.9780 +- 0.0000 A 13:49:07 Magnetic Field Measurement Measuring the magnet strength... 13:49:07 Integrated Voltage Measurement... 13:49:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000223256 Vs 13:49:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000048195 Vs 13:49:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000223102 Vs 13:49:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000047445 Vs 13:50:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000223026 Vs 13:50:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000047232 Vs 13:50:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000223074 Vs 13:50:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000047751 Vs 13:50:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000135385 +- 0.000000221 Vs 13:50:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000135385 +- 0.000000221 Vs BL = -0.01353852 +- 0.00002207 Tm 13:50:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01354 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.01354 0.00002 -0.01354 0.00000 13:50:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01354 0.00002 SL = -0.0135385 +- 0.0000221 Tm^2/m^n 13:50:38 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0135385 +- 0.0000221 Tm^2/m^n 13:50:40 Magnet Current, Imag = -5.9790 A Vtrans = -0.059790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:50:42 Magnet Current, Imag = -5.9790 A Vtrans = -0.059791 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:50:44 Magnet Current, Imag = -5.9790 A Vtrans = -0.059791 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:50:46 Magnet Current, Imag = -5.9791 A Vtrans = -0.059791 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:50:46 Magnet Current Measurement: Imag = -5.9790 +- 0.0000 A 13:50:46 Magnet current ramping to -4.0000 A... 13:51:02 Magnet Current, Imag = -3.9485 A Vtrans = -0.039485 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:51:03 Magnet Current, Imag = -3.9485 A Vtrans = -0.039485 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:51:05 Magnet Current, Imag = -3.9486 A Vtrans = -0.039486 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:51:07 Magnet Current, Imag = -3.9486 A Vtrans = -0.039486 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:51:07 Magnet Current Measurement: Imag = -3.9486 +- 0.0000 A 13:51:07 Magnetic Field Measurement Measuring the magnet strength... 13:51:07 Integrated Voltage Measurement... 13:51:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000171383 Vs 13:51:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000003327 Vs 13:51:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000172465 Vs 13:51:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000004001 Vs 13:52:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000172479 Vs 13:52:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000005594 Vs 13:52:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000173258 Vs 13:52:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000005855 Vs 13:52:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000083851 +- 0.000000302 Vs 13:52:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000083851 +- 0.000000302 Vs BL = -0.00838510 +- 0.00003023 Tm 13:52:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00839 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00839 0.00003 -0.00839 0.00000 13:52:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00839 0.00003 SL = -0.0083851 +- 0.0000302 Tm^2/m^n 13:52:38 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0083851 +- 0.0000302 Tm^2/m^n 13:52:39 Magnet Current, Imag = -3.9492 A Vtrans = -0.039492 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:52:41 Magnet Current, Imag = -3.9492 A Vtrans = -0.039492 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:52:43 Magnet Current, Imag = -3.9492 A Vtrans = -0.039492 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:52:45 Magnet Current, Imag = -3.9492 A Vtrans = -0.039492 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:52:45 Magnet Current Measurement: Imag = -3.9492 +- 0.0000 A 13:52:45 Magnet current ramping to -2.0000 A... 13:53:01 Magnet Current, Imag = -1.9188 A Vtrans = -0.019188 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:53:03 Magnet Current, Imag = -1.9188 A Vtrans = -0.019188 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:53:05 Magnet Current, Imag = -1.9187 A Vtrans = -0.019187 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:53:07 Magnet Current, Imag = -1.9188 A Vtrans = -0.019188 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:53:07 Magnet Current Measurement: Imag = -1.9188 +- 0.0000 A 13:53:07 Magnetic Field Measurement Measuring the magnet strength... 13:53:07 Integrated Voltage Measurement... 13:53:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000121869 Vs 13:53:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000057101 Vs 13:53:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000122635 Vs 13:53:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000057471 Vs 13:54:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000122267 Vs 13:54:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000056773 Vs 13:54:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000123076 Vs 13:54:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000058555 Vs 13:54:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000032493 +- 0.000000186 Vs 13:54:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000032493 +- 0.000000186 Vs BL = -0.00324933 +- 0.00001860 Tm 13:54:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00325 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00325 0.00002 -0.00325 0.00000 13:54:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00325 0.00002 SL = -0.0032493 +- 0.0000186 Tm^2/m^n 13:54:38 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0032493 +- 0.0000186 Tm^2/m^n 13:54:40 Magnet Current, Imag = -1.9191 A Vtrans = -0.019191 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:54:41 Magnet Current, Imag = -1.9192 A Vtrans = -0.019192 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:54:43 Magnet Current, Imag = -1.9192 A Vtrans = -0.019192 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:54:45 Magnet Current, Imag = -1.9192 A Vtrans = -0.019192 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:54:45 Magnet Current Measurement: Imag = -1.9192 +- 0.0000 A 13:54:45 Magnet current ramping to 0.0000 A... 13:55:01 Magnet Current, Imag = 0.1133 A Vtrans = 0.001133 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:03 Magnet Current, Imag = 0.1133 A Vtrans = 0.001133 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:05 Magnet Current, Imag = 0.1132 A Vtrans = 0.001132 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:07 Magnet Current, Imag = 0.1132 A Vtrans = 0.001132 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:07 Magnet Current Measurement: Imag = 0.1133 +- 0.0000 A 13:55:07 Magnetic Field Measurement Measuring the magnet strength... 13:55:07 Integrated Voltage Measurement... 13:55:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000071336 Vs 13:55:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000109877 Vs 13:55:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000071757 Vs 13:55:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000110424 Vs 13:56:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000071937 Vs 13:56:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000110010 Vs 13:56:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000071589 Vs 13:56:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000109082 Vs 13:56:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000019097 +- 0.000000230 Vs 13:56:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000019097 +- 0.000000230 Vs BL = 0.00190968 +- 0.00002305 Tm 13:56:37 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00191 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00191 0.00002 0.00191 0.00000 13:56:37 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00191 0.00002 SL = 0.0019097 +- 0.0000230 Tm^2/m^n 13:56:37 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0019097 +- 0.0000230 Tm^2/m^n 13:56:39 Magnet Current, Imag = 0.1131 A Vtrans = 0.001131 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:56:41 Magnet Current, Imag = 0.1132 A Vtrans = 0.001132 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:56:43 Magnet Current, Imag = 0.1132 A Vtrans = 0.001132 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:56:45 Magnet Current, Imag = 0.1131 A Vtrans = 0.001131 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:56:45 Magnet Current Measurement: Imag = 0.1132 +- 0.0000 A 13:56:45 Magnet current ramping to 2.0000 A... 13:57:01 Magnet Current, Imag = 2.1451 A Vtrans = 0.021451 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:57:03 Magnet Current, Imag = 2.1451 A Vtrans = 0.021451 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:57:05 Magnet Current, Imag = 2.1451 A Vtrans = 0.021451 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:57:07 Magnet Current, Imag = 2.1451 A Vtrans = 0.021451 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:57:07 Magnet Current Measurement: Imag = 2.1451 +- 0.0000 A 13:57:07 Magnetic Field Measurement Measuring the magnet strength... 13:57:07 Integrated Voltage Measurement... 13:57:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000020878 Vs 13:57:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000162603 Vs 13:57:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000019852 Vs 13:57:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000162458 Vs 13:58:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000020974 Vs 13:58:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000161677 Vs 13:58:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000019920 Vs 13:58:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000161989 Vs 13:58:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000070888 +- 0.000000347 Vs 13:58:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000070888 +- 0.000000347 Vs BL = 0.00708879 +- 0.00003473 Tm 13:58:37 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00709 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00709 0.00003 0.00709 0.00000 13:58:37 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00709 0.00003 SL = 0.0070888 +- 0.0000347 Tm^2/m^n 13:58:37 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0070888 +- 0.0000347 Tm^2/m^n 13:58:39 Magnet Current, Imag = 2.1448 A Vtrans = 0.021448 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:58:41 Magnet Current, Imag = 2.1448 A Vtrans = 0.021448 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:58:43 Magnet Current, Imag = 2.1448 A Vtrans = 0.021448 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:58:45 Magnet Current, Imag = 2.1448 A Vtrans = 0.021448 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:58:45 Magnet Current Measurement: Imag = 2.1448 +- 0.0000 A 13:58:45 Magnet current ramping to 4.0000 A... 13:59:01 Magnet Current, Imag = 4.1762 A Vtrans = 0.041762 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:59:03 Magnet Current, Imag = 4.1761 A Vtrans = 0.041762 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:59:05 Magnet Current, Imag = 4.1761 A Vtrans = 0.041761 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:59:07 Magnet Current, Imag = 4.1761 A Vtrans = 0.041761 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:59:07 Magnet Current Measurement: Imag = 4.1761 +- 0.0000 A 13:59:07 Magnetic Field Measurement Measuring the magnet strength... 13:59:07 Integrated Voltage Measurement... 13:59:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000030807 Vs 13:59:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000214375 Vs 13:59:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000031276 Vs 13:59:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000214821 Vs 14:00:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000030619 Vs 14:00:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000215964 Vs 14:00:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000031040 Vs 14:00:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000215023 Vs 14:00:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000122991 +- 0.000000253 Vs 14:00:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000122991 +- 0.000000253 Vs BL = 0.01229908 +- 0.00002525 Tm 14:00:37 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.01230 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.01230 0.00003 0.01230 0.00000 14:00:37 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.01230 0.00003 SL = 0.0122991 +- 0.0000253 Tm^2/m^n 14:00:37 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0122991 +- 0.0000253 Tm^2/m^n 14:00:39 Magnet Current, Imag = 4.1755 A Vtrans = 0.041755 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:00:41 Magnet Current, Imag = 4.1755 A Vtrans = 0.041755 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:00:43 Magnet Current, Imag = 4.1756 A Vtrans = 0.041756 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:00:45 Magnet Current, Imag = 4.1756 A Vtrans = 0.041756 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:00:45 Magnet Current Measurement: Imag = 4.1756 +- 0.0000 A 14:00:45 Magnet current ramping to 6.0000 A... 14:01:01 Magnet Current, Imag = 6.2067 A Vtrans = 0.062067 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:01:03 Magnet Current, Imag = 6.2066 A Vtrans = 0.062066 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:01:04 Magnet Current, Imag = 6.2066 A Vtrans = 0.062066 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:01:06 Magnet Current, Imag = 6.2065 A Vtrans = 0.062065 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:01:06 Magnet Current Measurement: Imag = 6.2066 +- 0.0001 A 14:01:06 Magnetic Field Measurement Measuring the magnet strength... 14:01:06 Integrated Voltage Measurement... 14:01:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000082417 Vs 14:01:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000267008 Vs 14:01:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000082799 Vs 14:01:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000266626 Vs 14:02:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000083531 Vs 14:02:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000267123 Vs 14:02:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000083953 Vs 14:02:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000264724 Vs 14:02:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000174773 +- 0.000000355 Vs 14:02:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000174773 +- 0.000000355 Vs BL = 0.01747725 +- 0.00003547 Tm 14:02:37 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.01748 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.01748 0.00004 0.01748 0.00000 14:02:37 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.01748 0.00004 SL = 0.0174773 +- 0.0000355 Tm^2/m^n 14:02:37 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0174773 +- 0.0000355 Tm^2/m^n 14:02:39 Magnet Current, Imag = 6.2053 A Vtrans = 0.062053 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:02:41 Magnet Current, Imag = 6.2053 A Vtrans = 0.062053 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:02:43 Magnet Current, Imag = 6.2052 A Vtrans = 0.062052 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:02:45 Magnet Current, Imag = 6.2053 A Vtrans = 0.062053 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:02:45 Magnet Current Measurement: Imag = 6.2053 +- 0.0000 A 14:02:45 Magnet current ramping to 8.0000 A... 14:03:01 Magnet Current, Imag = 8.2358 A Vtrans = 0.082358 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:03:03 Magnet Current, Imag = 8.2356 A Vtrans = 0.082356 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:03:04 Magnet Current, Imag = 8.2355 A Vtrans = 0.082355 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:03:06 Magnet Current, Imag = 8.2353 A Vtrans = 0.082353 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:03:06 Magnet Current Measurement: Imag = 8.2355 +- 0.0002 A 14:03:06 Magnetic Field Measurement Measuring the magnet strength... 14:03:06 Integrated Voltage Measurement... 14:03:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000135555 Vs 14:03:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000317135 Vs 14:03:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000136373 Vs 14:03:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000317575 Vs 14:04:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000135313 Vs 14:04:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000317344 Vs 14:04:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000136045 Vs 14:04:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000318290 Vs 14:04:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000226704 +- 0.000000373 Vs 14:04:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000226704 +- 0.000000373 Vs BL = 0.02267038 +- 0.00003734 Tm 14:04:37 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.02267 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.02267 0.00004 0.02267 0.00000 14:04:37 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.02267 0.00004 SL = 0.0226704 +- 0.0000373 Tm^2/m^n 14:04:37 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0226704 +- 0.0000373 Tm^2/m^n 14:04:39 Magnet Current, Imag = 8.2334 A Vtrans = 0.082334 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:04:41 Magnet Current, Imag = 8.2333 A Vtrans = 0.082333 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:04:43 Magnet Current, Imag = 8.2333 A Vtrans = 0.082333 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:04:44 Magnet Current, Imag = 8.2333 A Vtrans = 0.082333 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:04:44 Magnet Current Measurement: Imag = 8.2333 +- 0.0000 A 14:04:45 Magnet current ramping to 10.0000 A... 14:05:01 Magnet Current, Imag = 10.2621 A Vtrans = 0.102621 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:05:02 Magnet Current, Imag = 10.2619 A Vtrans = 0.102619 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:05:04 Magnet Current, Imag = 10.2616 A Vtrans = 0.102616 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:05:06 Magnet Current, Imag = 10.2615 A Vtrans = 0.102615 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:05:06 Magnet Current Measurement: Imag = 10.2618 +- 0.0002 A 14:05:06 Magnetic Field Measurement Measuring the magnet strength... 14:05:06 Integrated Voltage Measurement... 14:05:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000187459 Vs 14:05:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000369919 Vs 14:05:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000186172 Vs 14:05:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000371425 Vs 14:06:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000186291 Vs 14:06:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000371542 Vs 14:06:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000187597 Vs 14:06:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000371045 Vs 14:06:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000278931 +- 0.000000239 Vs 14:06:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000278931 +- 0.000000239 Vs BL = 0.02789313 +- 0.00002392 Tm 14:06:37 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.02789 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.02789 0.00002 0.02789 0.00000 14:06:37 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.02789 0.00002 SL = 0.0278931 +- 0.0000239 Tm^2/m^n 14:06:37 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0278931 +- 0.0000239 Tm^2/m^n 14:06:39 Magnet Current, Imag = 10.2586 A Vtrans = 0.102586 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:41 Magnet Current, Imag = 10.2585 A Vtrans = 0.102585 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:43 Magnet Current, Imag = 10.2586 A Vtrans = 0.102586 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:45 Magnet Current, Imag = 10.2585 A Vtrans = 0.102585 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:45 Magnet Current Measurement: Imag = 10.2586 +- 0.0001 A 14:06:45 Magnet current ramping to 12.0000 A... 14:07:01 Magnet Current, Imag = 12.2866 A Vtrans = 0.122866 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:07:03 Magnet Current, Imag = 12.2863 A Vtrans = 0.122863 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:07:05 Magnet Current, Imag = 12.2860 A Vtrans = 0.122860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:07:07 Magnet Current, Imag = 12.2857 A Vtrans = 0.122857 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:07:07 Magnet Current Measurement: Imag = 12.2861 +- 0.0003 A 14:07:07 Magnetic Field Measurement Measuring the magnet strength... 14:07:07 Integrated Voltage Measurement... 14:07:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000238799 Vs 14:07:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000423419 Vs 14:07:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000238405 Vs 14:07:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000423004 Vs 14:08:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000238858 Vs 14:08:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000422901 Vs 14:08:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000237238 Vs 14:08:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000424255 Vs 14:08:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000330860 +- 0.000000158 Vs 14:08:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000330860 +- 0.000000158 Vs BL = 0.03308599 +- 0.00001578 Tm 14:08:39 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.03309 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.03309 0.00002 0.03309 0.00000 14:08:39 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.03309 0.00002 SL = 0.0330860 +- 0.0000158 Tm^2/m^n 14:08:39 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0330860 +- 0.0000158 Tm^2/m^n 14:08:41 Magnet Current, Imag = 12.2815 A Vtrans = 0.122815 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:43 Magnet Current, Imag = 12.2814 A Vtrans = 0.122814 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:44 Magnet Current, Imag = 12.2814 A Vtrans = 0.122814 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:46 Magnet Current, Imag = 12.2813 A Vtrans = 0.122813 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:46 Magnet Current Measurement: Imag = 12.2814 +- 0.0001 A 14:09:17 Magnet current ramping to 0.0000 A...