SLAC Magnetic Measurements Date: 04-19-2002 Time: 15:20:22 Project: spear3 Magnet Type: gdipole Magnet Name: 109D-036 Serial Number: Run Number: 9 Measurement Device: stretched wire Operator: sa Comment: BL vs. I, mains Standardization: 1 cycles from 0.0 A to 770.0 A to 0.0 A Test Currents (A): 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 500.0 525.0 550.0 575.0 600.0 625.0 650.0 675.0 700.0 650.0 600.0 550.0 500.0 450.0 400.0 15:20:47 Initial Zero Current Measurement, Imag_zero = 0.0000 A 15:20:47 Magnet current ramping to 15.0000 A... 15:21:19 Magnet current ramping to 770.0000 A... 15:25:37 Magnet current ramping to 0.0000 A... 15:30:29 Magnet current ramping to 50.0000 A... 15:30:53 Magnet Current, Imag = 59.9902 A Vtrans = 0.599902 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:54 Magnet Current, Imag = 44.4717 A Vtrans = 0.444717 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:55 Magnet Current, Imag = 48.3608 A Vtrans = 0.483608 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:57 Magnet Current, Imag = 51.0739 A Vtrans = 0.510739 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:57 Magnet Current Measurement: Imag = 50.9742 +- 5.7099 A 15:30:57 Magnetic Field Measurement Measuring the magnet strength... 15:30:57 Integrated Voltage Measurement... 15:31:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001143217 Vs 15:31:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001328407 Vs 15:31:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001100240 Vs 15:31:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001319122 Vs 15:31:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001096249 Vs 15:32:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001320343 Vs 15:32:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001104719 Vs 15:32:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001325758 Vs 15:32:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001217257 +- 0.000011024 Vs 15:32:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001217257 +- 0.000011024 Vs BL = 0.12172569 +- 0.00110235 Tm 15:32:28 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.12173 0.00110 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.12173 0.00110 0.12173 0.00000 15:32:28 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.12173 0.00110 SL = 0.1217257 +- 0.0011024 Tm^2/m^n 15:32:28 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1217257 +- 0.0011024 Tm^2/m^n 15:32:29 Magnet Current, Imag = 49.5729 A Vtrans = 0.495729 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:30 Magnet Current, Imag = 49.5959 A Vtrans = 0.495959 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:32 Magnet Current, Imag = 49.5778 A Vtrans = 0.495778 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:33 Magnet Current, Imag = 49.6093 A Vtrans = 0.496093 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:33 Magnet Current Measurement: Imag = 49.5890 +- 0.0145 A 15:32:33 Magnet current ramping to 100.0000 A... 15:32:56 Magnet Current, Imag = 99.6318 A Vtrans = 0.996318 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:58 Magnet Current, Imag = 99.6358 A Vtrans = 0.996358 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:59 Magnet Current, Imag = 99.6567 A Vtrans = 0.996567 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:33:01 Magnet Current, Imag = 99.6444 A Vtrans = 0.996444 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:33:01 Magnet Current Measurement: Imag = 99.6422 +- 0.0095 A 15:33:01 Magnetic Field Measurement Measuring the magnet strength... 15:33:01 Integrated Voltage Measurement... 15:33:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002300335 Vs 15:33:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002524024 Vs 15:33:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002302086 Vs 15:33:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002520338 Vs 15:33:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002303517 Vs 15:34:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002520080 Vs 15:34:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002300193 Vs 15:34:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002523117 Vs 15:34:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002411711 +- 0.000000346 Vs 15:34:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.002411711 +- 0.000000346 Vs BL = 0.24117113 +- 0.00003462 Tm 15:34:31 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.24117 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.24117 0.00003 0.24117 0.00000 15:34:31 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.24117 0.00003 SL = 0.2411711 +- 0.0000346 Tm^2/m^n 15:34:31 Magnet Strength Measurement Harmonic Number = 1 SL = 0.2411711 +- 0.0000346 Tm^2/m^n 15:34:33 Magnet Current, Imag = 99.6432 A Vtrans = 0.996432 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:34 Magnet Current, Imag = 99.6118 A Vtrans = 0.996118 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:36 Magnet Current, Imag = 99.6126 A Vtrans = 0.996126 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:37 Magnet Current, Imag = 99.6294 A Vtrans = 0.996294 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:37 Magnet Current Measurement: Imag = 99.6242 +- 0.0130 A 15:34:37 Magnet current ramping to 150.0000 A... 15:35:00 Magnet Current, Imag = 149.6692 A Vtrans = 1.496692 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:35:01 Magnet Current, Imag = 149.6921 A Vtrans = 1.496921 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:35:03 Magnet Current, Imag = 149.6677 A Vtrans = 1.496677 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:35:04 Magnet Current, Imag = 149.6843 A Vtrans = 1.496843 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:35:04 Magnet Current Measurement: Imag = 149.6783 +- 0.0103 A 15:35:04 Magnetic Field Measurement Measuring the magnet strength... 15:35:04 Integrated Voltage Measurement... 15:35:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003515427 Vs 15:35:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003736343 Vs 15:35:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003510539 Vs 15:35:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003736577 Vs 15:36:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003515831 Vs 15:36:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003740146 Vs 15:36:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003511047 Vs 15:36:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003733037 Vs 15:36:32 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003624868 +- 0.000002263 Vs 15:36:32 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.003624868 +- 0.000002263 Vs BL = 0.36248684 +- 0.00022626 Tm 15:36:35 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.36249 0.00023 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.36249 0.00023 0.36249 0.00000 15:36:35 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.36249 0.00023 SL = 0.3624868 +- 0.0002263 Tm^2/m^n 15:36:35 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3624868 +- 0.0002263 Tm^2/m^n 15:36:36 Magnet Current, Imag = 149.6899 A Vtrans = 1.496899 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:38 Magnet Current, Imag = 149.6843 A Vtrans = 1.496843 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:39 Magnet Current, Imag = 149.6914 A Vtrans = 1.496914 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:41 Magnet Current, Imag = 149.6938 A Vtrans = 1.496938 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:41 Magnet Current Measurement: Imag = 149.6898 +- 0.0035 A 15:36:41 Magnet current ramping to 200.0000 A... 15:37:04 Magnet Current, Imag = 199.6877 A Vtrans = 1.996877 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:05 Magnet Current, Imag = 199.6888 A Vtrans = 1.996888 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:07 Magnet Current, Imag = 199.6721 A Vtrans = 1.996721 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:08 Magnet Current, Imag = 199.7055 A Vtrans = 1.997055 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:08 Magnet Current Measurement: Imag = 199.6885 +- 0.0118 A 15:37:08 Magnetic Field Measurement Measuring the magnet strength... 15:37:08 Integrated Voltage Measurement... 15:37:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004725485 Vs 15:37:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004939607 Vs 15:37:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004714003 Vs 15:37:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004945554 Vs 15:38:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004719922 Vs 15:38:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004953558 Vs 15:38:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004715767 Vs 15:38:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004941198 Vs 15:38:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004831887 +- 0.000003163 Vs 15:38:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004831887 +- 0.000003163 Vs BL = 0.48318868 +- 0.00031631 Tm 15:38:39 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.48319 0.00032 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.48319 0.00032 0.48319 0.00000 15:38:39 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.48319 0.00032 SL = 0.4831887 +- 0.0003163 Tm^2/m^n 15:38:39 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4831887 +- 0.0003163 Tm^2/m^n 15:38:41 Magnet Current, Imag = 199.7031 A Vtrans = 1.997031 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:42 Magnet Current, Imag = 199.7037 A Vtrans = 1.997037 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:43 Magnet Current, Imag = 199.7061 A Vtrans = 1.997061 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:45 Magnet Current, Imag = 199.7077 A Vtrans = 1.997077 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:45 Magnet Current Measurement: Imag = 199.7052 +- 0.0019 A 15:38:45 Magnet current ramping to 250.0000 A... 15:39:08 Magnet Current, Imag = 249.7595 A Vtrans = 2.497595 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:09 Magnet Current, Imag = 249.7799 A Vtrans = 2.497799 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:11 Magnet Current, Imag = 249.7705 A Vtrans = 2.497705 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:12 Magnet Current, Imag = 249.7722 A Vtrans = 2.497722 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:12 Magnet Current Measurement: Imag = 249.7705 +- 0.0073 A 15:39:12 Magnetic Field Measurement Measuring the magnet strength... 15:39:12 Integrated Voltage Measurement... 15:39:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005930769 Vs 15:39:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006149379 Vs 15:39:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005934247 Vs 15:39:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006168589 Vs 15:40:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005938071 Vs 15:40:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006156727 Vs 15:40:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005932939 Vs 15:40:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006161025 Vs 15:40:40 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006046468 +- 0.000004078 Vs 15:40:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006046468 +- 0.000004078 Vs BL = 0.60464680 +- 0.00040778 Tm 15:40:43 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.60465 0.00041 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.60465 0.00041 0.60465 0.00000 15:40:43 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.60465 0.00041 SL = 0.6046468 +- 0.0004078 Tm^2/m^n 15:40:43 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6046468 +- 0.0004078 Tm^2/m^n 15:40:44 Magnet Current, Imag = 249.7718 A Vtrans = 2.497718 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:46 Magnet Current, Imag = 249.7846 A Vtrans = 2.497846 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:47 Magnet Current, Imag = 249.7760 A Vtrans = 2.497760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:49 Magnet Current, Imag = 249.7587 A Vtrans = 2.497587 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:49 Magnet Current Measurement: Imag = 249.7728 +- 0.0093 A 15:40:49 Magnet current ramping to 300.0000 A... 15:41:11 Magnet Current, Imag = 299.8352 A Vtrans = 2.998352 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:13 Magnet Current, Imag = 299.8135 A Vtrans = 2.998135 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:14 Magnet Current, Imag = 299.8324 A Vtrans = 2.998324 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:16 Magnet Current, Imag = 299.8178 A Vtrans = 2.998178 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:16 Magnet Current Measurement: Imag = 299.8247 +- 0.0093 A 15:41:16 Magnetic Field Measurement Measuring the magnet strength... 15:41:16 Integrated Voltage Measurement... 15:41:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007145843 Vs 15:41:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007363121 Vs 15:41:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007146016 Vs 15:42:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007371197 Vs 15:42:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007141797 Vs 15:42:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007363577 Vs 15:42:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007130074 Vs 15:42:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007353515 Vs 15:42:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007251892 +- 0.000006213 Vs 15:42:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.007251892 +- 0.000006213 Vs BL = 0.72518925 +- 0.00062125 Tm 15:42:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.72519 0.00062 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.72519 0.00062 0.72519 0.00000 15:42:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.72519 0.00062 SL = 0.7251893 +- 0.0006213 Tm^2/m^n 15:42:47 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7251893 +- 0.0006213 Tm^2/m^n 15:42:48 Magnet Current, Imag = 299.8242 A Vtrans = 2.998242 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:42:49 Magnet Current, Imag = 299.8188 A Vtrans = 2.998188 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:42:51 Magnet Current, Imag = 299.8043 A Vtrans = 2.998043 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:42:52 Magnet Current, Imag = 299.7854 A Vtrans = 2.997854 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:42:52 Magnet Current Measurement: Imag = 299.8082 +- 0.0150 A 15:42:52 Magnet current ramping to 350.0000 A... 15:43:16 Magnet Current, Imag = 349.8720 A Vtrans = 3.498720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:18 Magnet Current, Imag = 349.9030 A Vtrans = 3.499030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:20 Magnet Current, Imag = 349.8890 A Vtrans = 3.498890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:21 Magnet Current, Imag = 349.8760 A Vtrans = 3.498760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:22 Magnet Current Measurement: Imag = 349.8850 +- 0.0121 A 15:43:22 Magnetic Field Measurement Measuring the magnet strength... 15:43:22 Integrated Voltage Measurement... 15:43:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008353412 Vs 15:43:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008581693 Vs 15:43:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008353661 Vs 15:44:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008578975 Vs 15:44:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008356243 Vs 15:44:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008575772 Vs 15:44:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008347875 Vs 15:44:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008572092 Vs 15:44:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008464965 +- 0.000002934 Vs 15:44:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.008464965 +- 0.000002934 Vs BL = 0.84649653 +- 0.00029336 Tm 15:44:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.84650 0.00029 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.84650 0.00029 0.84650 0.00000 15:44:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.84650 0.00029 SL = 0.8464965 +- 0.0002934 Tm^2/m^n 15:44:52 Magnet Strength Measurement Harmonic Number = 1 SL = 0.8464965 +- 0.0002934 Tm^2/m^n 15:44:54 Magnet Current, Imag = 349.9040 A Vtrans = 3.499040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:44:56 Magnet Current, Imag = 349.8830 A Vtrans = 3.498830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:44:58 Magnet Current, Imag = 349.8900 A Vtrans = 3.498900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:00 Magnet Current, Imag = 349.8780 A Vtrans = 3.498780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:00 Magnet Current Measurement: Imag = 349.8888 +- 0.0098 A 15:45:00 Magnet current ramping to 400.0000 A... 15:45:24 Magnet Current, Imag = 399.9110 A Vtrans = 3.999110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:25 Magnet Current, Imag = 399.9110 A Vtrans = 3.999110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:27 Magnet Current, Imag = 399.9030 A Vtrans = 3.999030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:29 Magnet Current, Imag = 399.9130 A Vtrans = 3.999130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:29 Magnet Current Measurement: Imag = 399.9095 +- 0.0038 A 15:45:29 Magnetic Field Measurement Measuring the magnet strength... 15:45:29 Integrated Voltage Measurement... 15:45:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009569765 Vs 15:45:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009791155 Vs 15:46:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009560076 Vs 15:46:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009782119 Vs 15:46:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009563039 Vs 15:46:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009799217 Vs 15:46:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009571325 Vs 15:46:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009792557 Vs 15:46:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009678657 +- 0.000004396 Vs 15:46:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009678657 +- 0.000004396 Vs BL = 0.96786567 +- 0.00043956 Tm 15:47:00 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.96787 0.00044 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.96787 0.00044 0.96787 0.00000 15:47:00 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.96787 0.00044 SL = 0.9678657 +- 0.0004396 Tm^2/m^n 15:47:00 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9678657 +- 0.0004396 Tm^2/m^n 15:47:02 Magnet Current, Imag = 399.9120 A Vtrans = 3.999120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:03 Magnet Current, Imag = 399.9150 A Vtrans = 3.999150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:05 Magnet Current, Imag = 399.9000 A Vtrans = 3.999000 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:06 Magnet Current, Imag = 399.9010 A Vtrans = 3.999010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:06 Magnet Current Measurement: Imag = 399.9070 +- 0.0066 A 15:47:07 Magnet current ramping to 450.0000 A... 15:47:30 Magnet Current, Imag = 449.9680 A Vtrans = 4.499680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:31 Magnet Current, Imag = 449.9620 A Vtrans = 4.499620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:33 Magnet Current, Imag = 449.9590 A Vtrans = 4.499590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:35 Magnet Current, Imag = 449.9590 A Vtrans = 4.499590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:35 Magnet Current Measurement: Imag = 449.9620 +- 0.0037 A 15:47:35 Magnetic Field Measurement Measuring the magnet strength... 15:47:35 Integrated Voltage Measurement... 15:47:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010774129 Vs 15:47:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011005078 Vs 15:48:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010773141 Vs 15:48:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.010999171 Vs 15:48:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010775711 Vs 15:48:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011000363 Vs 15:48:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010772077 Vs 15:49:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.010995099 Vs 15:49:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010886846 +- 0.000002242 Vs 15:49:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.010886846 +- 0.000002242 Vs BL = 1.08868462 +- 0.00022424 Tm 15:49:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.08868 0.00022 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.08868 0.00022 1.08868 0.00000 15:49:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.08868 0.00022 SL = 1.0886846 +- 0.0002242 Tm^2/m^n 15:49:06 Magnet Strength Measurement Harmonic Number = 1 SL = 1.0886846 +- 0.0002242 Tm^2/m^n 15:49:07 Magnet Current, Imag = 449.9360 A Vtrans = 4.499360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:09 Magnet Current, Imag = 449.9380 A Vtrans = 4.499380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:10 Magnet Current, Imag = 449.9450 A Vtrans = 4.499450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:12 Magnet Current, Imag = 449.9410 A Vtrans = 4.499410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:12 Magnet Current Measurement: Imag = 449.9400 +- 0.0034 A 15:49:12 Magnet current ramping to 500.0000 A... 15:49:35 Magnet Current, Imag = 500.0150 A Vtrans = 5.000150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:36 Magnet Current, Imag = 500.0310 A Vtrans = 5.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:38 Magnet Current, Imag = 500.0370 A Vtrans = 5.000370 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:39 Magnet Current, Imag = 500.0320 A Vtrans = 5.000320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:40 Magnet Current Measurement: Imag = 500.0287 +- 0.0083 A 15:49:40 Magnetic Field Measurement Measuring the magnet strength... 15:49:40 Integrated Voltage Measurement... 15:49:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011985461 Vs 15:50:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012201607 Vs 15:50:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011974779 Vs 15:50:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012205907 Vs 15:50:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011976763 Vs 15:50:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012206496 Vs 15:50:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011978681 Vs 15:51:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012204789 Vs 15:51:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012091810 +- 0.000001136 Vs 15:51:08 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012091810 +- 0.000001136 Vs BL = 1.20918102 +- 0.00011362 Tm 15:51:11 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.20918 0.00011 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.20918 0.00011 1.20918 0.00000 15:51:11 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.20918 0.00011 SL = 1.2091810 +- 0.0001136 Tm^2/m^n 15:51:11 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2091810 +- 0.0001136 Tm^2/m^n 15:51:13 Magnet Current, Imag = 500.0240 A Vtrans = 5.000240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:15 Magnet Current, Imag = 499.9920 A Vtrans = 4.999920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:16 Magnet Current, Imag = 500.0330 A Vtrans = 5.000330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:18 Magnet Current, Imag = 500.0310 A Vtrans = 5.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:18 Magnet Current Measurement: Imag = 500.0200 +- 0.0165 A 15:51:18 Magnet current ramping to 525.0000 A... 15:51:33 Magnet Current, Imag = 525.0450 A Vtrans = 5.250450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:35 Magnet Current, Imag = 525.0470 A Vtrans = 5.250470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:37 Magnet Current, Imag = 525.0500 A Vtrans = 5.250500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:38 Magnet Current, Imag = 525.0600 A Vtrans = 5.250600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:38 Magnet Current Measurement: Imag = 525.0505 +- 0.0058 A 15:51:38 Magnetic Field Measurement Measuring the magnet strength... 15:51:38 Integrated Voltage Measurement... 15:51:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012586933 Vs 15:52:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012800059 Vs 15:52:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012572047 Vs 15:52:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012807959 Vs 15:52:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012575520 Vs 15:52:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012805143 Vs 15:52:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012581614 Vs 15:53:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012800900 Vs 15:53:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012691272 +- 0.000001364 Vs 15:53:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012691272 +- 0.000001364 Vs BL = 1.26912719 +- 0.00013639 Tm 15:53:10 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.26913 0.00014 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.26913 0.00014 1.26913 0.00000 15:53:10 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.26913 0.00014 SL = 1.2691272 +- 0.0001364 Tm^2/m^n 15:53:10 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2691272 +- 0.0001364 Tm^2/m^n 15:53:12 Magnet Current, Imag = 525.0610 A Vtrans = 5.250610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:13 Magnet Current, Imag = 525.0670 A Vtrans = 5.250670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:15 Magnet Current, Imag = 525.0680 A Vtrans = 5.250680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:16 Magnet Current, Imag = 525.0510 A Vtrans = 5.250510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:16 Magnet Current Measurement: Imag = 525.0617 +- 0.0068 A 15:53:16 Magnet current ramping to 550.0000 A... 15:53:32 Magnet Current, Imag = 550.0580 A Vtrans = 5.500580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:34 Magnet Current, Imag = 550.0230 A Vtrans = 5.500230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:35 Magnet Current, Imag = 550.0440 A Vtrans = 5.500440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:37 Magnet Current, Imag = 550.0130 A Vtrans = 5.500130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:37 Magnet Current Measurement: Imag = 550.0345 +- 0.0176 A 15:53:37 Magnetic Field Measurement Measuring the magnet strength... 15:53:37 Integrated Voltage Measurement... 15:53:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013168657 Vs 15:54:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013395799 Vs 15:54:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013157277 Vs 15:54:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013398293 Vs 15:54:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013171411 Vs 15:54:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013387027 Vs 15:54:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013173377 Vs 15:55:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013395409 Vs 15:55:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013280906 +- 0.000002573 Vs 15:55:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.013280906 +- 0.000002573 Vs BL = 1.32809063 +- 0.00025735 Tm 15:55:09 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.32809 0.00026 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.32809 0.00026 1.32809 0.00000 15:55:09 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.32809 0.00026 SL = 1.3280906 +- 0.0002573 Tm^2/m^n 15:55:09 Magnet Strength Measurement Harmonic Number = 1 SL = 1.3280906 +- 0.0002573 Tm^2/m^n 15:55:11 Magnet Current, Imag = 550.0590 A Vtrans = 5.500590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:12 Magnet Current, Imag = 550.0540 A Vtrans = 5.500540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:14 Magnet Current, Imag = 550.0660 A Vtrans = 5.500660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:16 Magnet Current, Imag = 550.0790 A Vtrans = 5.500790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:16 Magnet Current Measurement: Imag = 550.0645 +- 0.0094 A 15:55:16 Magnet current ramping to 575.0000 A... 15:55:31 Magnet Current, Imag = 575.0530 A Vtrans = 5.750530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:33 Magnet Current, Imag = 575.0560 A Vtrans = 5.750560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:34 Magnet Current, Imag = 575.0780 A Vtrans = 5.750780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:36 Magnet Current, Imag = 575.0770 A Vtrans = 5.750770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:36 Magnet Current Measurement: Imag = 575.0660 +- 0.0116 A 15:55:36 Magnetic Field Measurement Measuring the magnet strength... 15:55:36 Integrated Voltage Measurement... 15:55:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013750404 Vs 15:56:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013987074 Vs 15:56:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013763352 Vs 15:56:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013984023 Vs 15:56:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013745941 Vs 15:56:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013986341 Vs 15:56:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013757951 Vs 15:57:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013974696 Vs 15:57:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013868723 +- 0.000003044 Vs 15:57:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.013868723 +- 0.000003044 Vs BL = 1.38687227 +- 0.00030443 Tm 15:57:07 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.38687 0.00030 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.38687 0.00030 1.38687 0.00000 15:57:07 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.38687 0.00030 SL = 1.3868723 +- 0.0003044 Tm^2/m^n 15:57:07 Magnet Strength Measurement Harmonic Number = 1 SL = 1.3868723 +- 0.0003044 Tm^2/m^n 15:57:08 Magnet Current, Imag = 575.0660 A Vtrans = 5.750660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:10 Magnet Current, Imag = 575.0570 A Vtrans = 5.750570 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:12 Magnet Current, Imag = 575.0820 A Vtrans = 5.750820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:13 Magnet Current, Imag = 575.0730 A Vtrans = 5.750730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:13 Magnet Current Measurement: Imag = 575.0695 +- 0.0092 A 15:57:13 Magnet current ramping to 600.0000 A... 15:57:29 Magnet Current, Imag = 600.0730 A Vtrans = 6.000730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:30 Magnet Current, Imag = 600.0810 A Vtrans = 6.000810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:32 Magnet Current, Imag = 600.0750 A Vtrans = 6.000750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:34 Magnet Current, Imag = 600.0910 A Vtrans = 6.000910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:34 Magnet Current Measurement: Imag = 600.0800 +- 0.0070 A 15:57:34 Magnetic Field Measurement Measuring the magnet strength... 15:57:34 Integrated Voltage Measurement... 15:57:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014331222 Vs 15:57:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014557770 Vs 15:58:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014331527 Vs 15:58:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014555366 Vs 15:58:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014336435 Vs 15:58:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014562227 Vs 15:58:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014328822 Vs 15:59:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014546091 Vs 15:59:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014443682 +- 0.000004225 Vs 15:59:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014443682 +- 0.000004225 Vs BL = 1.44436824 +- 0.00042246 Tm 15:59:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.44437 0.00042 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.44437 0.00042 1.44437 0.00000 15:59:04 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.44437 0.00042 SL = 1.4443682 +- 0.0004225 Tm^2/m^n 15:59:05 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4443682 +- 0.0004225 Tm^2/m^n 15:59:06 Magnet Current, Imag = 600.0980 A Vtrans = 6.000980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:08 Magnet Current, Imag = 600.0850 A Vtrans = 6.000850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:09 Magnet Current, Imag = 600.0900 A Vtrans = 6.000900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:11 Magnet Current, Imag = 600.0820 A Vtrans = 6.000820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:11 Magnet Current Measurement: Imag = 600.0888 +- 0.0061 A 15:59:11 Magnet current ramping to 625.0000 A... 15:59:26 Magnet Current, Imag = 625.1220 A Vtrans = 6.251220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:28 Magnet Current, Imag = 625.1230 A Vtrans = 6.251230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:30 Magnet Current, Imag = 625.1320 A Vtrans = 6.251320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:31 Magnet Current, Imag = 625.1250 A Vtrans = 6.251250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:31 Magnet Current Measurement: Imag = 625.1255 +- 0.0039 A 15:59:31 Magnetic Field Measurement Measuring the magnet strength... 15:59:31 Integrated Voltage Measurement... 15:59:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014886870 Vs 15:59:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015119665 Vs 16:00:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014894110 Vs 16:00:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015119362 Vs 16:00:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014898141 Vs 16:00:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015119760 Vs 16:00:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014887925 Vs 16:00:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015104620 Vs 16:00:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015003807 +- 0.000004798 Vs 16:00:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015003807 +- 0.000004798 Vs BL = 1.50038066 +- 0.00047984 Tm 16:01:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.50038 0.00048 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.50038 0.00048 1.50038 0.00000 16:01:02 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.50038 0.00048 SL = 1.5003807 +- 0.0004798 Tm^2/m^n 16:01:02 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5003807 +- 0.0004798 Tm^2/m^n 16:01:04 Magnet Current, Imag = 625.1340 A Vtrans = 6.251340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:01:05 Magnet Current, Imag = 625.1460 A Vtrans = 6.251460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:01:07 Magnet Current, Imag = 625.1170 A Vtrans = 6.251170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:01:08 Magnet Current, Imag = 625.1300 A Vtrans = 6.251300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:01:08 Magnet Current Measurement: Imag = 625.1318 +- 0.0104 A 16:01:08 Magnet current ramping to 650.0000 A... 16:01:24 Magnet Current, Imag = 650.1650 A Vtrans = 6.501650 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:01:26 Magnet Current, Imag = 650.1690 A Vtrans = 6.501690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:01:27 Magnet Current, Imag = 650.1770 A Vtrans = 6.501770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:01:29 Magnet Current, Imag = 650.1600 A Vtrans = 6.501600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:01:29 Magnet Current Measurement: Imag = 650.1677 +- 0.0062 A 16:01:29 Magnetic Field Measurement Measuring the magnet strength... 16:01:29 Integrated Voltage Measurement... 16:01:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015419302 Vs 16:01:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015650923 Vs 16:02:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015419305 Vs 16:02:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015653581 Vs 16:02:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015424851 Vs 16:02:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015649607 Vs 16:02:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015425273 Vs 16:02:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015650278 Vs 16:02:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015536640 +- 0.000001001 Vs 16:02:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015536640 +- 0.000001001 Vs BL = 1.55366401 +- 0.00010011 Tm 16:03:00 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.55366 0.00010 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.55366 0.00010 1.55366 0.00000 16:03:00 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.55366 0.00010 SL = 1.5536640 +- 0.0001001 Tm^2/m^n 16:03:00 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5536640 +- 0.0001001 Tm^2/m^n 16:03:01 Magnet Current, Imag = 650.1510 A Vtrans = 6.501510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:03 Magnet Current, Imag = 650.1920 A Vtrans = 6.501920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:05 Magnet Current, Imag = 650.1690 A Vtrans = 6.501690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:06 Magnet Current, Imag = 650.1740 A Vtrans = 6.501740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:06 Magnet Current Measurement: Imag = 650.1715 +- 0.0146 A 16:03:06 Magnet current ramping to 675.0000 A... 16:03:22 Magnet Current, Imag = 675.1880 A Vtrans = 6.751880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:23 Magnet Current, Imag = 675.1710 A Vtrans = 6.751710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:25 Magnet Current, Imag = 675.2110 A Vtrans = 6.752110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:26 Magnet Current, Imag = 675.2250 A Vtrans = 6.752250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:27 Magnet Current Measurement: Imag = 675.1988 +- 0.0208 A 16:03:27 Magnetic Field Measurement Measuring the magnet strength... 16:03:27 Integrated Voltage Measurement... 16:03:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015923019 Vs 16:03:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016147506 Vs 16:04:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015930512 Vs 16:04:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016150021 Vs 16:04:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015921670 Vs 16:04:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016155182 Vs 16:04:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015918721 Vs 16:04:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016142311 Vs 16:04:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016036118 +- 0.000003696 Vs 16:04:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016036118 +- 0.000003696 Vs BL = 1.60361178 +- 0.00036961 Tm 16:04:57 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.60361 0.00037 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.60361 0.00037 1.60361 0.00000 16:04:57 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.60361 0.00037 SL = 1.6036118 +- 0.0003696 Tm^2/m^n 16:04:57 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6036118 +- 0.0003696 Tm^2/m^n 16:04:59 Magnet Current, Imag = 675.2000 A Vtrans = 6.752000 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:01 Magnet Current, Imag = 675.1880 A Vtrans = 6.751880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:02 Magnet Current, Imag = 675.1850 A Vtrans = 6.751850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:04 Magnet Current, Imag = 675.2240 A Vtrans = 6.752240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:04 Magnet Current Measurement: Imag = 675.1992 +- 0.0154 A 16:05:04 Magnet current ramping to 700.0000 A... 16:05:19 Magnet Current, Imag = 700.2390 A Vtrans = 7.002390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:21 Magnet Current, Imag = 700.2260 A Vtrans = 7.002260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:23 Magnet Current, Imag = 700.2070 A Vtrans = 7.002070 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:24 Magnet Current, Imag = 700.2030 A Vtrans = 7.002030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:24 Magnet Current Measurement: Imag = 700.2188 +- 0.0146 A 16:05:24 Magnetic Field Measurement Measuring the magnet strength... 16:05:24 Integrated Voltage Measurement... 16:05:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016388437 Vs 16:05:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016616161 Vs 16:05:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016400771 Vs 16:06:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016622729 Vs 16:06:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016384986 Vs 16:06:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016616836 Vs 16:06:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016393239 Vs 16:06:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016620247 Vs 16:06:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016505426 +- 0.000004240 Vs 16:06:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016505426 +- 0.000004240 Vs BL = 1.65054258 +- 0.00042396 Tm 16:06:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.65054 0.00042 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.65054 0.00042 1.65054 0.00000 16:06:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.65054 0.00042 SL = 1.6505426 +- 0.0004240 Tm^2/m^n 16:06:55 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6505426 +- 0.0004240 Tm^2/m^n 16:06:57 Magnet Current, Imag = 700.2230 A Vtrans = 7.002230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:06:58 Magnet Current, Imag = 700.2120 A Vtrans = 7.002120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:00 Magnet Current, Imag = 700.2490 A Vtrans = 7.002490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:01 Magnet Current, Imag = 700.2280 A Vtrans = 7.002280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:01 Magnet Current Measurement: Imag = 700.2280 +- 0.0134 A 16:07:01 Magnet current ramping to 650.0000 A... 16:07:24 Magnet Current, Imag = 650.1460 A Vtrans = 6.501460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:26 Magnet Current, Imag = 650.1660 A Vtrans = 6.501660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:27 Magnet Current, Imag = 650.1640 A Vtrans = 6.501640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:29 Magnet Current, Imag = 650.1610 A Vtrans = 6.501610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:29 Magnet Current Measurement: Imag = 650.1592 +- 0.0079 A 16:07:29 Magnetic Field Measurement Measuring the magnet strength... 16:07:29 Integrated Voltage Measurement... 16:07:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015482567 Vs 16:07:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015714571 Vs 16:08:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015477035 Vs 16:08:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015708397 Vs 16:08:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015491375 Vs 16:08:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015710601 Vs 16:08:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015485214 Vs 16:08:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015707267 Vs 16:08:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015597129 +- 0.000003051 Vs 16:08:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015597129 +- 0.000003051 Vs BL = 1.55971285 +- 0.00030509 Tm 16:09:00 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.55971 0.00031 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.55971 0.00031 1.55971 0.00000 16:09:00 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.55971 0.00031 SL = 1.5597129 +- 0.0003051 Tm^2/m^n 16:09:00 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5597129 +- 0.0003051 Tm^2/m^n 16:09:01 Magnet Current, Imag = 650.1820 A Vtrans = 6.501820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:03 Magnet Current, Imag = 650.1840 A Vtrans = 6.501840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:05 Magnet Current, Imag = 650.1670 A Vtrans = 6.501670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:06 Magnet Current, Imag = 650.1910 A Vtrans = 6.501910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:06 Magnet Current Measurement: Imag = 650.1810 +- 0.0087 A 16:09:06 Magnet current ramping to 600.0000 A... 16:09:29 Magnet Current, Imag = 600.0810 A Vtrans = 6.000810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:31 Magnet Current, Imag = 600.0830 A Vtrans = 6.000830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:32 Magnet Current, Imag = 600.0900 A Vtrans = 6.000900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:34 Magnet Current, Imag = 600.0860 A Vtrans = 6.000860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:34 Magnet Current Measurement: Imag = 600.0850 +- 0.0034 A 16:09:34 Magnetic Field Measurement Measuring the magnet strength... 16:09:34 Integrated Voltage Measurement... 16:09:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014391339 Vs 16:09:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014619263 Vs 16:10:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014400685 Vs 16:10:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014622581 Vs 16:10:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014392365 Vs 16:10:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014623214 Vs 16:10:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014396913 Vs 16:11:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014622243 Vs 16:11:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014508575 +- 0.000002329 Vs 16:11:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014508575 +- 0.000002329 Vs BL = 1.45085754 +- 0.00023290 Tm 16:11:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.45086 0.00023 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.45086 0.00023 1.45086 0.00000 16:11:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.45086 0.00023 SL = 1.4508575 +- 0.0002329 Tm^2/m^n 16:11:05 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4508575 +- 0.0002329 Tm^2/m^n 16:11:06 Magnet Current, Imag = 600.0900 A Vtrans = 6.000900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:08 Magnet Current, Imag = 600.0980 A Vtrans = 6.000980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:09 Magnet Current, Imag = 600.1000 A Vtrans = 6.001000 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:11 Magnet Current, Imag = 600.0940 A Vtrans = 6.000940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:11 Magnet Current Measurement: Imag = 600.0955 +- 0.0038 A 16:11:11 Magnet current ramping to 550.0000 A... 16:11:34 Magnet Current, Imag = 550.0450 A Vtrans = 5.500450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:36 Magnet Current, Imag = 550.0360 A Vtrans = 5.500360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:37 Magnet Current, Imag = 550.0620 A Vtrans = 5.500620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:39 Magnet Current, Imag = 550.0690 A Vtrans = 5.500690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:39 Magnet Current Measurement: Imag = 550.0530 +- 0.0131 A 16:11:39 Magnetic Field Measurement Measuring the magnet strength... 16:11:39 Integrated Voltage Measurement... 16:11:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013225837 Vs 16:12:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013448187 Vs 16:12:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013223843 Vs 16:12:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013450223 Vs 16:12:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013230529 Vs 16:12:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013458780 Vs 16:12:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013224193 Vs 16:13:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013452719 Vs 16:13:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013339289 +- 0.000003153 Vs 16:13:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.013339289 +- 0.000003153 Vs BL = 1.33392889 +- 0.00031526 Tm 16:13:10 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.33393 0.00032 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.33393 0.00032 1.33393 0.00000 16:13:10 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.33393 0.00032 SL = 1.3339289 +- 0.0003153 Tm^2/m^n 16:13:10 Magnet Strength Measurement Harmonic Number = 1 SL = 1.3339289 +- 0.0003153 Tm^2/m^n 16:13:11 Magnet Current, Imag = 550.0250 A Vtrans = 5.500250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:13 Magnet Current, Imag = 550.0400 A Vtrans = 5.500400 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:14 Magnet Current, Imag = 550.0400 A Vtrans = 5.500400 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:16 Magnet Current, Imag = 550.0190 A Vtrans = 5.500190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:16 Magnet Current Measurement: Imag = 550.0310 +- 0.0092 A 16:13:16 Magnet current ramping to 500.0000 A... 16:13:39 Magnet Current, Imag = 500.0220 A Vtrans = 5.000220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:41 Magnet Current, Imag = 500.0430 A Vtrans = 5.000430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:43 Magnet Current, Imag = 500.0560 A Vtrans = 5.000560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:44 Magnet Current, Imag = 500.0740 A Vtrans = 5.000740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:44 Magnet Current Measurement: Imag = 500.0487 +- 0.0190 A 16:13:44 Magnetic Field Measurement Measuring the magnet strength... 16:13:44 Integrated Voltage Measurement... 16:13:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012026871 Vs 16:14:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012257695 Vs 16:14:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012031057 Vs 16:14:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012249803 Vs 16:14:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012022946 Vs 16:14:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012250951 Vs 16:15:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012029659 Vs 16:15:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012255059 Vs 16:15:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012140505 +- 0.000002194 Vs 16:15:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012140505 +- 0.000002194 Vs BL = 1.21405052 +- 0.00021940 Tm 16:15:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.21405 0.00022 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.21405 0.00022 1.21405 0.00000 16:15:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.21405 0.00022 SL = 1.2140505 +- 0.0002194 Tm^2/m^n 16:15:15 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2140505 +- 0.0002194 Tm^2/m^n 16:15:17 Magnet Current, Imag = 500.0330 A Vtrans = 5.000330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:15:18 Magnet Current, Imag = 500.0460 A Vtrans = 5.000460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:15:20 Magnet Current, Imag = 500.0490 A Vtrans = 5.000490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:15:21 Magnet Current, Imag = 500.0460 A Vtrans = 5.000460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:15:21 Magnet Current Measurement: Imag = 500.0435 +- 0.0062 A 16:15:21 Magnet current ramping to 450.0000 A... 16:15:45 Magnet Current, Imag = 449.9450 A Vtrans = 4.499450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:15:46 Magnet Current, Imag = 449.9510 A Vtrans = 4.499510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:15:48 Magnet Current, Imag = 449.9560 A Vtrans = 4.499560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:15:49 Magnet Current, Imag = 449.9560 A Vtrans = 4.499560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:15:49 Magnet Current Measurement: Imag = 449.9520 +- 0.0045 A 16:15:49 Magnetic Field Measurement Measuring the magnet strength... 16:15:49 Integrated Voltage Measurement... 16:16:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010822385 Vs 16:16:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011049277 Vs 16:16:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010821419 Vs 16:16:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011054923 Vs 16:16:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010822795 Vs 16:16:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011051994 Vs 16:17:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010817138 Vs 16:17:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011041990 Vs 16:17:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010935240 +- 0.000003384 Vs 16:17:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.010935240 +- 0.000003384 Vs BL = 1.09352401 +- 0.00033837 Tm 16:17:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.09352 0.00034 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.09352 0.00034 1.09352 0.00000 16:17:20 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.09352 0.00034 SL = 1.0935240 +- 0.0003384 Tm^2/m^n 16:17:20 Magnet Strength Measurement Harmonic Number = 1 SL = 1.0935240 +- 0.0003384 Tm^2/m^n 16:17:22 Magnet Current, Imag = 449.9420 A Vtrans = 4.499420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:23 Magnet Current, Imag = 449.9490 A Vtrans = 4.499490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:25 Magnet Current, Imag = 449.9360 A Vtrans = 4.499360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:27 Magnet Current, Imag = 449.9410 A Vtrans = 4.499410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:27 Magnet Current Measurement: Imag = 449.9420 +- 0.0046 A 16:17:27 Magnet current ramping to 400.0000 A... 16:17:50 Magnet Current, Imag = 399.9060 A Vtrans = 3.999060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:51 Magnet Current, Imag = 399.8930 A Vtrans = 3.998930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:53 Magnet Current, Imag = 399.8890 A Vtrans = 3.998890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:54 Magnet Current, Imag = 399.8870 A Vtrans = 3.998870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:54 Magnet Current Measurement: Imag = 399.8937 +- 0.0074 A 16:17:54 Magnetic Field Measurement Measuring the magnet strength... 16:17:54 Integrated Voltage Measurement... 16:18:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009607383 Vs 16:18:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009833963 Vs 16:18:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009611475 Vs 16:18:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009829379 Vs 16:18:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009609413 Vs 16:19:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009832615 Vs 16:19:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009616831 Vs 16:19:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009834625 Vs 16:19:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009721960 +- 0.000002185 Vs 16:19:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009721960 +- 0.000002185 Vs BL = 0.97219605 +- 0.00021851 Tm 16:19:25 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.97220 0.00022 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.97220 0.00022 0.97220 0.00000 16:19:25 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.97220 0.00022 SL = 0.9721960 +- 0.0002185 Tm^2/m^n 16:19:25 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9721960 +- 0.0002185 Tm^2/m^n 16:19:27 Magnet Current, Imag = 399.9010 A Vtrans = 3.999010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:28 Magnet Current, Imag = 399.9170 A Vtrans = 3.999170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:30 Magnet Current, Imag = 399.8810 A Vtrans = 3.998810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:31 Magnet Current, Imag = 399.8920 A Vtrans = 3.998920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:31 Magnet Current Measurement: Imag = 399.8978 +- 0.0132 A 16:20:02 Magnet current ramping to 0.0000 A...