SLAC Magnetic Measurements Date: 04-19-2002 Time: 16:31:30 Project: spear3 Magnet Type: gdipole Magnet Name: 109D-036 Serial Number: Run Number: 10 Measurement Device: stretched wire Operator: sa Comment: BL vs. I, Trim Test Currents (A): -12.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 16:31:55 Initial Zero Current Measurement, Imag_zero = 0.0000 A 16:32:25 Magnet current ramping to -12.0000 A... 16:33:17 Magnet Current, Imag = -12.0937 A Vtrans = -0.120937 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:19 Magnet Current, Imag = -12.0934 A Vtrans = -0.120934 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:21 Magnet Current, Imag = -12.0930 A Vtrans = -0.120930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:22 Magnet Current, Imag = -12.0927 A Vtrans = -0.120927 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:22 Magnet Current Measurement: Imag = -12.0932 +- 0.0004 A 16:33:22 Magnetic Field Measurement Measuring the magnet strength... 16:33:23 Integrated Voltage Measurement... 16:33:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000383831 Vs 16:33:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000194451 Vs 16:33:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000383609 Vs 16:34:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000194129 Vs 16:34:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000383698 Vs 16:34:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000194528 Vs 16:34:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000383182 Vs 16:34:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000195202 Vs 16:34:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000289079 +- 0.000000124 Vs 16:34:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000289079 +- 0.000000124 Vs BL = -0.02890789 +- 0.00001243 Tm 16:34:53 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02891 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.02891 0.00001 -0.02891 0.00000 16:34:53 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02891 0.00001 SL = -0.0289079 +- 0.0000124 Tm^2/m^n 16:34:53 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0289079 +- 0.0000124 Tm^2/m^n 16:34:55 Magnet Current, Imag = -12.0836 A Vtrans = -0.120836 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:34:57 Magnet Current, Imag = -12.0835 A Vtrans = -0.120835 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:34:59 Magnet Current, Imag = -12.0833 A Vtrans = -0.120833 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:01 Magnet Current, Imag = -12.0832 A Vtrans = -0.120832 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:01 Magnet Current Measurement: Imag = -12.0834 +- 0.0001 A 16:35:01 Magnet current ramping to -10.0000 A... 16:35:17 Magnet Current, Imag = -10.0375 A Vtrans = -0.100375 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:19 Magnet Current, Imag = -10.0375 A Vtrans = -0.100375 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:21 Magnet Current, Imag = -10.0375 A Vtrans = -0.100375 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:23 Magnet Current, Imag = -10.0375 A Vtrans = -0.100375 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:23 Magnet Current Measurement: Imag = -10.0375 +- 0.0000 A 16:35:23 Magnetic Field Measurement Measuring the magnet strength... 16:35:23 Integrated Voltage Measurement... 16:35:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000331171 Vs 16:35:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000143861 Vs 16:35:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000331931 Vs 16:36:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000143962 Vs 16:36:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000332188 Vs 16:36:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000143736 Vs 16:36:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000332508 Vs 16:36:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000144279 Vs 16:36:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000237954 +- 0.000000310 Vs 16:36:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000237954 +- 0.000000310 Vs BL = -0.02379544 +- 0.00003102 Tm 16:36:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02380 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.02380 0.00003 -0.02380 0.00000 16:36:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02380 0.00003 SL = -0.0237954 +- 0.0000310 Tm^2/m^n 16:36:54 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0237954 +- 0.0000310 Tm^2/m^n 16:36:56 Magnet Current, Imag = -10.0372 A Vtrans = -0.100372 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:36:58 Magnet Current, Imag = -10.0373 A Vtrans = -0.100373 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:37:00 Magnet Current, Imag = -10.0373 A Vtrans = -0.100373 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:37:01 Magnet Current, Imag = -10.0373 A Vtrans = -0.100373 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:37:01 Magnet Current Measurement: Imag = -10.0373 +- 0.0000 A 16:37:02 Magnet current ramping to -8.0000 A... 16:37:18 Magnet Current, Imag = -8.0077 A Vtrans = -0.080077 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:37:19 Magnet Current, Imag = -8.0078 A Vtrans = -0.080078 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:37:21 Magnet Current, Imag = -8.0078 A Vtrans = -0.080078 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:37:23 Magnet Current, Imag = -8.0078 A Vtrans = -0.080078 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:37:23 Magnet Current Measurement: Imag = -8.0078 +- 0.0000 A 16:37:23 Magnetic Field Measurement Measuring the magnet strength... 16:37:23 Integrated Voltage Measurement... 16:37:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000280087 Vs 16:37:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000093229 Vs 16:37:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000279945 Vs 16:38:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000093368 Vs 16:38:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000280673 Vs 16:38:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000092619 Vs 16:38:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000281511 Vs 16:38:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000093591 Vs 16:38:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000186878 +- 0.000000389 Vs 16:38:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000186878 +- 0.000000389 Vs BL = -0.01868780 +- 0.00003886 Tm 16:38:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01869 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.01869 0.00004 -0.01869 0.00000 16:38:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01869 0.00004 SL = -0.0186878 +- 0.0000389 Tm^2/m^n 16:38:54 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0186878 +- 0.0000389 Tm^2/m^n 16:38:56 Magnet Current, Imag = -8.0089 A Vtrans = -0.080089 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:38:58 Magnet Current, Imag = -8.0090 A Vtrans = -0.080090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:39:00 Magnet Current, Imag = -8.0089 A Vtrans = -0.080089 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:39:02 Magnet Current, Imag = -8.0090 A Vtrans = -0.080090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:39:02 Magnet Current Measurement: Imag = -8.0090 +- 0.0000 A 16:39:02 Magnet current ramping to -6.0000 A... 16:39:18 Magnet Current, Imag = -5.9784 A Vtrans = -0.059784 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:39:20 Magnet Current, Imag = -5.9785 A Vtrans = -0.059785 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:39:22 Magnet Current, Imag = -5.9785 A Vtrans = -0.059785 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:39:23 Magnet Current, Imag = -5.9785 A Vtrans = -0.059785 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:39:24 Magnet Current Measurement: Imag = -5.9784 +- 0.0000 A 16:39:24 Magnetic Field Measurement Measuring the magnet strength... 16:39:24 Integrated Voltage Measurement... 16:39:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000229479 Vs 16:39:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000041087 Vs 16:39:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000230020 Vs 16:40:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000039569 Vs 16:40:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000229624 Vs 16:40:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000040671 Vs 16:40:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000230031 Vs 16:40:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000040113 Vs 16:40:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000135074 +- 0.000000178 Vs 16:40:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000135074 +- 0.000000178 Vs BL = -0.01350743 +- 0.00001782 Tm 16:40:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01351 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.01351 0.00002 -0.01351 0.00000 16:40:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01351 0.00002 SL = -0.0135074 +- 0.0000178 Tm^2/m^n 16:40:54 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0135074 +- 0.0000178 Tm^2/m^n 16:40:56 Magnet Current, Imag = -5.9794 A Vtrans = -0.059794 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:40:58 Magnet Current, Imag = -5.9795 A Vtrans = -0.059795 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:41:00 Magnet Current, Imag = -5.9796 A Vtrans = -0.059796 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:41:02 Magnet Current, Imag = -5.9795 A Vtrans = -0.059795 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:41:02 Magnet Current Measurement: Imag = -5.9795 +- 0.0001 A 16:41:02 Magnet current ramping to -4.0000 A... 16:41:18 Magnet Current, Imag = -3.9489 A Vtrans = -0.039489 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:41:20 Magnet Current, Imag = -3.9490 A Vtrans = -0.039490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:41:22 Magnet Current, Imag = -3.9490 A Vtrans = -0.039490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:41:24 Magnet Current, Imag = -3.9490 A Vtrans = -0.039490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:41:24 Magnet Current Measurement: Imag = -3.9490 +- 0.0001 A 16:41:24 Magnetic Field Measurement Measuring the magnet strength... 16:41:24 Integrated Voltage Measurement... 16:41:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000177656 Vs 16:41:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000008871 Vs 16:41:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000177999 Vs 16:42:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000010387 Vs 16:42:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000177493 Vs 16:42:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000010007 Vs 16:42:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000177285 Vs 16:42:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000009111 Vs 16:42:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000084007 +- 0.000000257 Vs 16:42:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000084007 +- 0.000000257 Vs BL = -0.00840071 +- 0.00002574 Tm 16:42:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00840 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00840 0.00003 -0.00840 0.00000 16:42:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00840 0.00003 SL = -0.0084007 +- 0.0000257 Tm^2/m^n 16:42:54 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0084007 +- 0.0000257 Tm^2/m^n 16:42:56 Magnet Current, Imag = -3.9497 A Vtrans = -0.039497 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:42:58 Magnet Current, Imag = -3.9497 A Vtrans = -0.039497 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:43:00 Magnet Current, Imag = -3.9496 A Vtrans = -0.039496 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:43:02 Magnet Current, Imag = -3.9497 A Vtrans = -0.039497 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:43:02 Magnet Current Measurement: Imag = -3.9497 +- 0.0001 A 16:43:02 Magnet current ramping to -2.0000 A... 16:43:18 Magnet Current, Imag = -1.9192 A Vtrans = -0.019192 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:43:20 Magnet Current, Imag = -1.9192 A Vtrans = -0.019192 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:43:22 Magnet Current, Imag = -1.9192 A Vtrans = -0.019192 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:43:23 Magnet Current, Imag = -1.9192 A Vtrans = -0.019192 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:43:24 Magnet Current Measurement: Imag = -1.9192 +- 0.0000 A 16:43:24 Magnetic Field Measurement Measuring the magnet strength... 16:43:24 Integrated Voltage Measurement... 16:43:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000126505 Vs 16:43:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000060956 Vs 16:43:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000126127 Vs 16:44:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000060567 Vs 16:44:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000125939 Vs 16:44:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000061148 Vs 16:44:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000127066 Vs 16:44:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000062769 Vs 16:44:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000032525 +- 0.000000267 Vs 16:44:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000032525 +- 0.000000267 Vs BL = -0.00325247 +- 0.00002672 Tm 16:44:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00325 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00325 0.00003 -0.00325 0.00000 16:44:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00325 0.00003 SL = -0.0032525 +- 0.0000267 Tm^2/m^n 16:44:54 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0032525 +- 0.0000267 Tm^2/m^n 16:44:56 Magnet Current, Imag = -1.9195 A Vtrans = -0.019195 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:44:58 Magnet Current, Imag = -1.9195 A Vtrans = -0.019195 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:45:00 Magnet Current, Imag = -1.9196 A Vtrans = -0.019196 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:45:02 Magnet Current, Imag = -1.9195 A Vtrans = -0.019195 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:45:02 Magnet Current Measurement: Imag = -1.9195 +- 0.0000 A 16:45:02 Magnet current ramping to 0.0000 A... 16:45:18 Magnet Current, Imag = 0.1130 A Vtrans = 0.001130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:45:20 Magnet Current, Imag = 0.1129 A Vtrans = 0.001129 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:45:22 Magnet Current, Imag = 0.1130 A Vtrans = 0.001130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:45:24 Magnet Current, Imag = 0.1129 A Vtrans = 0.001129 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:45:24 Magnet Current Measurement: Imag = 0.1130 +- 0.0000 A 16:45:24 Magnetic Field Measurement Measuring the magnet strength... 16:45:24 Integrated Voltage Measurement... 16:45:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000075823 Vs 16:45:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000115073 Vs 16:45:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000075836 Vs 16:46:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000115142 Vs 16:46:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000075319 Vs 16:46:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000114528 Vs 16:46:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000075796 Vs 16:46:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000113785 Vs 16:46:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000019469 +- 0.000000275 Vs 16:46:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000019469 +- 0.000000275 Vs BL = 0.00194692 +- 0.00002747 Tm 16:46:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00195 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00195 0.00003 0.00195 0.00000 16:46:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00195 0.00003 SL = 0.0019469 +- 0.0000275 Tm^2/m^n 16:46:54 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0019469 +- 0.0000275 Tm^2/m^n 16:46:56 Magnet Current, Imag = 0.1129 A Vtrans = 0.001129 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:46:58 Magnet Current, Imag = 0.1127 A Vtrans = 0.001127 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:00 Magnet Current, Imag = 0.1127 A Vtrans = 0.001127 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:02 Magnet Current, Imag = 0.1127 A Vtrans = 0.001127 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:02 Magnet Current Measurement: Imag = 0.1128 +- 0.0001 A 16:47:02 Magnet current ramping to 2.0000 A... 16:47:18 Magnet Current, Imag = 2.1448 A Vtrans = 0.021448 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:20 Magnet Current, Imag = 2.1448 A Vtrans = 0.021448 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:22 Magnet Current, Imag = 2.1448 A Vtrans = 0.021448 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:24 Magnet Current, Imag = 2.1447 A Vtrans = 0.021447 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:24 Magnet Current Measurement: Imag = 2.1447 +- 0.0000 A 16:47:24 Magnetic Field Measurement Measuring the magnet strength... 16:47:24 Integrated Voltage Measurement... 16:47:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000023756 Vs 16:47:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000166349 Vs 16:47:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000024222 Vs 16:48:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000165524 Vs 16:48:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000024353 Vs 16:48:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000165841 Vs 16:48:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000023349 Vs 16:48:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000164995 Vs 16:48:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000070879 +- 0.000000249 Vs 16:48:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000070879 +- 0.000000249 Vs BL = 0.00708785 +- 0.00002488 Tm 16:48:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00709 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00709 0.00002 0.00709 0.00000 16:48:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00709 0.00002 SL = 0.0070878 +- 0.0000249 Tm^2/m^n 16:48:54 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0070878 +- 0.0000249 Tm^2/m^n 16:48:56 Magnet Current, Imag = 2.1445 A Vtrans = 0.021445 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:48:58 Magnet Current, Imag = 2.1446 A Vtrans = 0.021446 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:49:00 Magnet Current, Imag = 2.1445 A Vtrans = 0.021445 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:49:02 Magnet Current, Imag = 2.1445 A Vtrans = 0.021445 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:49:02 Magnet Current Measurement: Imag = 2.1445 +- 0.0000 A 16:49:02 Magnet current ramping to 4.0000 A... 16:49:18 Magnet Current, Imag = 4.1760 A Vtrans = 0.041760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:49:20 Magnet Current, Imag = 4.1759 A Vtrans = 0.041759 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:49:22 Magnet Current, Imag = 4.1758 A Vtrans = 0.041758 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:49:24 Magnet Current, Imag = 4.1758 A Vtrans = 0.041758 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:49:24 Magnet Current Measurement: Imag = 4.1759 +- 0.0001 A 16:49:24 Magnetic Field Measurement Measuring the magnet strength... 16:49:24 Integrated Voltage Measurement... 16:49:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000028581 Vs 16:49:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000219303 Vs 16:49:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000027738 Vs 16:50:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000218826 Vs 16:50:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000027604 Vs 16:50:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000218691 Vs 16:50:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000028335 Vs 16:50:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000218381 Vs 16:50:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000123432 +- 0.000000304 Vs 16:50:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000123432 +- 0.000000304 Vs BL = 0.01234324 +- 0.00003039 Tm 16:50:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.01234 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.01234 0.00003 0.01234 0.00000 16:50:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.01234 0.00003 SL = 0.0123432 +- 0.0000304 Tm^2/m^n 16:50:54 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0123432 +- 0.0000304 Tm^2/m^n 16:50:56 Magnet Current, Imag = 4.1751 A Vtrans = 0.041751 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:50:58 Magnet Current, Imag = 4.1752 A Vtrans = 0.041752 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:51:00 Magnet Current, Imag = 4.1751 A Vtrans = 0.041751 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:51:02 Magnet Current, Imag = 4.1751 A Vtrans = 0.041751 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:51:02 Magnet Current Measurement: Imag = 4.1751 +- 0.0000 A 16:51:02 Magnet current ramping to 6.0000 A... 16:51:19 Magnet Current, Imag = 6.2063 A Vtrans = 0.062063 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:51:21 Magnet Current, Imag = 6.2063 A Vtrans = 0.062063 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:51:23 Magnet Current, Imag = 6.2061 A Vtrans = 0.062061 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:51:25 Magnet Current, Imag = 6.2061 A Vtrans = 0.062061 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:51:25 Magnet Current Measurement: Imag = 6.2062 +- 0.0001 A 16:51:25 Magnetic Field Measurement Measuring the magnet strength... 16:51:25 Integrated Voltage Measurement... 16:51:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000079241 Vs 16:51:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000271766 Vs 16:51:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000079792 Vs 16:52:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000270971 Vs 16:52:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000079070 Vs 16:52:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000271853 Vs 16:52:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000078663 Vs 16:52:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000270303 Vs 16:52:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000175207 +- 0.000000420 Vs 16:52:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000175207 +- 0.000000420 Vs BL = 0.01752073 +- 0.00004205 Tm 16:52:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.01752 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.01752 0.00004 0.01752 0.00000 16:52:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.01752 0.00004 SL = 0.0175207 +- 0.0000420 Tm^2/m^n 16:52:55 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0175207 +- 0.0000420 Tm^2/m^n 16:52:57 Magnet Current, Imag = 6.2050 A Vtrans = 0.062050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:52:59 Magnet Current, Imag = 6.2049 A Vtrans = 0.062049 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:53:01 Magnet Current, Imag = 6.2049 A Vtrans = 0.062049 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:53:03 Magnet Current, Imag = 6.2049 A Vtrans = 0.062049 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:53:03 Magnet Current Measurement: Imag = 6.2049 +- 0.0000 A 16:53:03 Magnet current ramping to 8.0000 A... 16:53:19 Magnet Current, Imag = 8.2355 A Vtrans = 0.082355 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:53:21 Magnet Current, Imag = 8.2353 A Vtrans = 0.082353 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:53:23 Magnet Current, Imag = 8.2352 A Vtrans = 0.082352 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:53:25 Magnet Current, Imag = 8.2350 A Vtrans = 0.082350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:53:25 Magnet Current Measurement: Imag = 8.2353 +- 0.0002 A 16:53:25 Magnetic Field Measurement Measuring the magnet strength... 16:53:25 Integrated Voltage Measurement... 16:53:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000129669 Vs 16:53:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000323694 Vs 16:53:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000130235 Vs 16:54:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000323501 Vs 16:54:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000130229 Vs 16:54:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000324151 Vs 16:54:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000130591 Vs 16:54:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000323704 Vs 16:54:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000226972 +- 0.000000208 Vs 16:54:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000226972 +- 0.000000208 Vs BL = 0.02269718 +- 0.00002085 Tm 16:54:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.02270 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.02270 0.00002 0.02270 0.00000 16:54:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.02270 0.00002 SL = 0.0226972 +- 0.0000208 Tm^2/m^n 16:54:55 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0226972 +- 0.0000208 Tm^2/m^n 16:54:57 Magnet Current, Imag = 8.2330 A Vtrans = 0.082330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:54:59 Magnet Current, Imag = 8.2330 A Vtrans = 0.082330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:55:01 Magnet Current, Imag = 8.2330 A Vtrans = 0.082330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:55:03 Magnet Current, Imag = 8.2329 A Vtrans = 0.082329 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:55:03 Magnet Current Measurement: Imag = 8.2330 +- 0.0000 A 16:55:03 Magnet current ramping to 10.0000 A... 16:55:19 Magnet Current, Imag = 10.2619 A Vtrans = 0.102619 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:55:21 Magnet Current, Imag = 10.2616 A Vtrans = 0.102616 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:55:23 Magnet Current, Imag = 10.2614 A Vtrans = 0.102614 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:55:25 Magnet Current, Imag = 10.2612 A Vtrans = 0.102612 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:55:25 Magnet Current Measurement: Imag = 10.2615 +- 0.0002 A 16:55:25 Magnetic Field Measurement Measuring the magnet strength... 16:55:25 Integrated Voltage Measurement... 16:55:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000182477 Vs 16:55:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000376811 Vs 16:55:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000181038 Vs 16:56:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000375338 Vs 16:56:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000183255 Vs 16:56:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000374446 Vs 16:56:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000181739 Vs 16:56:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000375939 Vs 16:56:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000278880 +- 0.000000516 Vs 16:56:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000278880 +- 0.000000516 Vs BL = 0.02788804 +- 0.00005161 Tm 16:56:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.02789 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.02789 0.00005 0.02789 0.00000 16:56:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.02789 0.00005 SL = 0.0278880 +- 0.0000516 Tm^2/m^n 16:56:55 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0278880 +- 0.0000516 Tm^2/m^n 16:56:57 Magnet Current, Imag = 10.2582 A Vtrans = 0.102582 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:56:59 Magnet Current, Imag = 10.2581 A Vtrans = 0.102581 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:57:01 Magnet Current, Imag = 10.2581 A Vtrans = 0.102581 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:57:03 Magnet Current, Imag = 10.2581 A Vtrans = 0.102581 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:57:03 Magnet Current Measurement: Imag = 10.2581 +- 0.0000 A 16:57:03 Magnet current ramping to 12.0000 A... 16:57:19 Magnet Current, Imag = 12.2863 A Vtrans = 0.122863 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:57:21 Magnet Current, Imag = 12.2861 A Vtrans = 0.122861 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:57:23 Magnet Current, Imag = 12.2857 A Vtrans = 0.122857 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:57:25 Magnet Current, Imag = 12.2855 A Vtrans = 0.122855 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:57:25 Magnet Current Measurement: Imag = 12.2859 +- 0.0003 A 16:57:25 Magnetic Field Measurement Measuring the magnet strength... 16:57:25 Integrated Voltage Measurement... 16:57:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000235252 Vs 16:57:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000427820 Vs 16:57:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000233583 Vs 16:58:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000427716 Vs 16:58:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000232139 Vs 16:58:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000429118 Vs 16:58:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000233708 Vs 16:58:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000427839 Vs 16:58:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000330897 +- 0.000000373 Vs 16:58:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000330897 +- 0.000000373 Vs BL = 0.03308969 +- 0.00003731 Tm 16:58:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.03309 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.03309 0.00004 0.03309 0.00000 16:58:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.03309 0.00004 SL = 0.0330897 +- 0.0000373 Tm^2/m^n 16:58:55 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0330897 +- 0.0000373 Tm^2/m^n 16:58:57 Magnet Current, Imag = 12.2811 A Vtrans = 0.122811 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:58:59 Magnet Current, Imag = 12.2811 A Vtrans = 0.122811 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:59:01 Magnet Current, Imag = 12.2811 A Vtrans = 0.122811 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:59:03 Magnet Current, Imag = 12.2810 A Vtrans = 0.122810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:59:03 Magnet Current Measurement: Imag = 12.2811 +- 0.0000 A 16:59:33 Magnet current ramping to 0.0000 A...