SLAC Magnetic Measurements Date: 02-19-2002 Time: 10:37:00 Project: spear3 Magnet Type: gdipole Magnet Name: 109D-035 Serial Number: Run Number: 12 Measurement Device: stretched wire Operator: jy Comment: BL v. I, mains Standardization: 1 cycles from 0.0 A to 770.0 A to 0.0 A Test Currents (A): 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 500.0 525.0 550.0 575.0 600.0 625.0 650.0 675.0 700.0 650.0 600.0 550.0 500.0 450.0 400.0 10:37:08 Initial Zero Current Measurement, Imag_zero = 0.0000 A 10:37:08 Magnet current ramping to 15.0000 A... 10:37:44 Magnet current ramping to 770.0000 A... 10:48:49 Magnet current ramping to 0.0000 A... 10:53:45 Magnet current ramping to 50.0000 A... 10:54:09 Magnet Current, Imag = 44.8681 A Vtrans = 0.448681 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:11 Magnet Current, Imag = 52.8457 A Vtrans = 0.528457 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:12 Magnet Current, Imag = 50.3733 A Vtrans = 0.503733 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:14 Magnet Current, Imag = 49.0356 A Vtrans = 0.490356 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:14 Magnet Current Measurement: Imag = 49.2807 +- 2.8911 A 10:54:14 Magnetic Field Measurement Measuring the magnet strength... 10:54:14 Integrated Voltage Measurement... 10:54:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000994929 Vs 10:54:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001418646 Vs 10:54:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001022982 Vs 10:55:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001412839 Vs 10:55:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001019866 Vs 10:55:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001413937 Vs 10:55:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001007198 Vs 10:55:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001411053 Vs 10:55:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001212681 +- 0.000004810 Vs 10:55:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001212681 +- 0.000004810 Vs BL = 0.12126813 +- 0.00048098 Tm 10:55:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.12127 0.00048 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.12127 0.00048 0.12127 0.00000 10:55:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.12127 0.00048 SL = 0.1212681 +- 0.0004810 Tm^2/m^n 10:55:49 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1212681 +- 0.0004810 Tm^2/m^n 10:55:51 Magnet Current, Imag = 49.7146 A Vtrans = 0.497146 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:55:52 Magnet Current, Imag = 49.7388 A Vtrans = 0.497388 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:55:53 Magnet Current, Imag = 49.7298 A Vtrans = 0.497298 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:55:55 Magnet Current, Imag = 49.7192 A Vtrans = 0.497192 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:55:55 Magnet Current Measurement: Imag = 49.7256 +- 0.0094 A 10:55:55 Magnet current ramping to 100.0000 A... 10:56:18 Magnet Current, Imag = 99.7567 A Vtrans = 0.997567 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:19 Magnet Current, Imag = 99.7656 A Vtrans = 0.997656 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:21 Magnet Current, Imag = 99.7658 A Vtrans = 0.997658 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:22 Magnet Current, Imag = 99.7712 A Vtrans = 0.997712 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:22 Magnet Current Measurement: Imag = 99.7648 +- 0.0052 A 10:56:22 Magnetic Field Measurement Measuring the magnet strength... 10:56:22 Integrated Voltage Measurement... 10:56:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002218879 Vs 10:56:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002603097 Vs 10:56:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002227881 Vs 10:57:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002608215 Vs 10:57:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002217799 Vs 10:57:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002611222 Vs 10:57:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002223069 Vs 10:57:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002605526 Vs 10:57:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002414461 +- 0.000002498 Vs 10:57:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.002414461 +- 0.000002498 Vs BL = 0.24144609 +- 0.00024978 Tm 10:57:57 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.24145 0.00025 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.24145 0.00025 0.24145 0.00000 10:57:57 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.24145 0.00025 SL = 0.2414461 +- 0.0002498 Tm^2/m^n 10:57:57 Magnet Strength Measurement Harmonic Number = 1 SL = 0.2414461 +- 0.0002498 Tm^2/m^n 10:57:58 Magnet Current, Imag = 99.7700 A Vtrans = 0.997700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:00 Magnet Current, Imag = 99.7152 A Vtrans = 0.997152 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:01 Magnet Current, Imag = 99.7380 A Vtrans = 0.997380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:03 Magnet Current, Imag = 99.7602 A Vtrans = 0.997602 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:03 Magnet Current Measurement: Imag = 99.7458 +- 0.0212 A 10:58:03 Magnet current ramping to 150.0000 A... 10:58:27 Magnet Current, Imag = 149.7743 A Vtrans = 1.497743 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:28 Magnet Current, Imag = 149.7809 A Vtrans = 1.497809 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:30 Magnet Current, Imag = 149.8128 A Vtrans = 1.498128 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:31 Magnet Current, Imag = 149.8202 A Vtrans = 1.498202 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:31 Magnet Current Measurement: Imag = 149.7971 +- 0.0198 A 10:58:31 Magnetic Field Measurement Measuring the magnet strength... 10:58:31 Integrated Voltage Measurement... 10:58:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003415456 Vs 10:58:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003823347 Vs 10:59:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003430463 Vs 10:59:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003823559 Vs 10:59:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003422319 Vs 10:59:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003821871 Vs 10:59:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003431787 Vs 11:00:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003821239 Vs 11:00:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003623755 +- 0.000003159 Vs 11:00:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.003623755 +- 0.000003159 Vs BL = 0.36237553 +- 0.00031590 Tm 11:00:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.36238 0.00032 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.36238 0.00032 0.36238 0.00000 11:00:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.36238 0.00032 SL = 0.3623755 +- 0.0003159 Tm^2/m^n 11:00:05 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3623755 +- 0.0003159 Tm^2/m^n 11:00:06 Magnet Current, Imag = 149.8213 A Vtrans = 1.498213 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:08 Magnet Current, Imag = 149.8351 A Vtrans = 1.498351 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:09 Magnet Current, Imag = 149.8235 A Vtrans = 1.498235 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:11 Magnet Current, Imag = 149.8031 A Vtrans = 1.498031 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:11 Magnet Current Measurement: Imag = 149.8207 +- 0.0115 A 11:00:11 Magnet current ramping to 200.0000 A... 11:00:33 Magnet Current, Imag = 199.8343 A Vtrans = 1.998343 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:35 Magnet Current, Imag = 199.8230 A Vtrans = 1.998230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:36 Magnet Current, Imag = 199.8448 A Vtrans = 1.998448 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:38 Magnet Current, Imag = 199.8381 A Vtrans = 1.998381 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:38 Magnet Current Measurement: Imag = 199.8350 +- 0.0079 A 11:00:38 Magnetic Field Measurement Measuring the magnet strength... 11:00:38 Integrated Voltage Measurement... 11:00:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004638885 Vs 11:01:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005042133 Vs 11:01:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004627307 Vs 11:01:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005028349 Vs 11:01:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004654148 Vs 11:01:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005035150 Vs 11:01:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004623411 Vs 11:02:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005039557 Vs 11:02:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004836118 +- 0.000006750 Vs 11:02:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004836118 +- 0.000006750 Vs BL = 0.48361175 +- 0.00067500 Tm 11:02:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.48361 0.00067 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.48361 0.00067 0.48361 0.00000 11:02:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.48361 0.00067 SL = 0.4836118 +- 0.0006750 Tm^2/m^n 11:02:12 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4836118 +- 0.0006750 Tm^2/m^n 11:02:13 Magnet Current, Imag = 199.8008 A Vtrans = 1.998008 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:15 Magnet Current, Imag = 199.7954 A Vtrans = 1.997954 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:16 Magnet Current, Imag = 199.8209 A Vtrans = 1.998209 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:18 Magnet Current, Imag = 199.8216 A Vtrans = 1.998216 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:18 Magnet Current Measurement: Imag = 199.8097 +- 0.0117 A 11:02:18 Magnet current ramping to 250.0000 A... 11:02:41 Magnet Current, Imag = 249.8609 A Vtrans = 2.498609 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:43 Magnet Current, Imag = 249.8651 A Vtrans = 2.498651 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:44 Magnet Current, Imag = 249.8694 A Vtrans = 2.498694 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:46 Magnet Current, Imag = 249.8593 A Vtrans = 2.498593 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:46 Magnet Current Measurement: Imag = 249.8637 +- 0.0039 A 11:02:46 Magnetic Field Measurement Measuring the magnet strength... 11:02:46 Integrated Voltage Measurement... 11:02:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005848589 Vs 11:03:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006246391 Vs 11:03:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005860101 Vs 11:03:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006249694 Vs 11:03:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005856107 Vs 11:03:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006253726 Vs 11:04:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005861361 Vs 11:04:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006256871 Vs 11:04:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006054105 +- 0.000004188 Vs 11:04:19 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006054105 +- 0.000004188 Vs BL = 0.60541051 +- 0.00041882 Tm 11:04:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.60541 0.00042 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.60541 0.00042 0.60541 0.00000 11:04:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.60541 0.00042 SL = 0.6054105 +- 0.0004188 Tm^2/m^n 11:04:22 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6054105 +- 0.0004188 Tm^2/m^n 11:04:23 Magnet Current, Imag = 249.8917 A Vtrans = 2.498917 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:24 Magnet Current, Imag = 249.8971 A Vtrans = 2.498971 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:26 Magnet Current, Imag = 249.8538 A Vtrans = 2.498538 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:27 Magnet Current, Imag = 249.8527 A Vtrans = 2.498527 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:27 Magnet Current Measurement: Imag = 249.8738 +- 0.0207 A 11:04:27 Magnet current ramping to 300.0000 A... 11:04:52 Magnet Current, Imag = 299.9121 A Vtrans = 2.999121 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:54 Magnet Current, Imag = 299.9122 A Vtrans = 2.999122 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:55 Magnet Current, Imag = 299.8969 A Vtrans = 2.998969 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:58 Magnet Current, Imag = 299.8832 A Vtrans = 2.998832 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:58 Magnet Current Measurement: Imag = 299.9011 +- 0.0121 A 11:04:58 Magnetic Field Measurement Measuring the magnet strength... 11:04:58 Integrated Voltage Measurement... 11:05:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007069520 Vs 11:05:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007467428 Vs 11:05:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007052675 Vs 11:05:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007454005 Vs 11:05:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007059929 Vs 11:06:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007452798 Vs 11:06:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007077547 Vs 11:06:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007466235 Vs 11:06:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007262517 +- 0.000007833 Vs 11:06:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.007262517 +- 0.000007833 Vs BL = 0.72625172 +- 0.00078332 Tm 11:06:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.72625 0.00078 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.72625 0.00078 0.72625 0.00000 11:06:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.72625 0.00078 SL = 0.7262517 +- 0.0007833 Tm^2/m^n 11:06:33 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7262517 +- 0.0007833 Tm^2/m^n 11:06:34 Magnet Current, Imag = 299.9013 A Vtrans = 2.999013 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:35 Magnet Current, Imag = 299.8790 A Vtrans = 2.998790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:37 Magnet Current, Imag = 299.8805 A Vtrans = 2.998805 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:38 Magnet Current, Imag = 299.8862 A Vtrans = 2.998862 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:38 Magnet Current Measurement: Imag = 299.8868 +- 0.0088 A 11:06:38 Magnet current ramping to 350.0000 A... 11:07:02 Magnet Current, Imag = 349.9900 A Vtrans = 3.499900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:07:04 Magnet Current, Imag = 349.9490 A Vtrans = 3.499490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:07:06 Magnet Current, Imag = 349.9820 A Vtrans = 3.499820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:07:08 Magnet Current, Imag = 349.9600 A Vtrans = 3.499600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:07:08 Magnet Current Measurement: Imag = 349.9702 +- 0.0165 A 11:07:08 Magnetic Field Measurement Measuring the magnet strength... 11:07:08 Integrated Voltage Measurement... 11:07:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008284093 Vs 11:07:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008659605 Vs 11:07:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008295432 Vs 11:07:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008670481 Vs 11:08:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008286023 Vs 11:08:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008675231 Vs 11:08:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008274777 Vs 11:08:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008667667 Vs 11:08:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008476664 +- 0.000005198 Vs 11:08:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.008476664 +- 0.000005198 Vs BL = 0.84766636 +- 0.00051984 Tm 11:08:40 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.84767 0.00052 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.84767 0.00052 0.84767 0.00000 11:08:40 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.84767 0.00052 SL = 0.8476664 +- 0.0005198 Tm^2/m^n 11:08:40 Magnet Strength Measurement Harmonic Number = 1 SL = 0.8476664 +- 0.0005198 Tm^2/m^n 11:08:42 Magnet Current, Imag = 349.9420 A Vtrans = 3.499420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:08:44 Magnet Current, Imag = 349.9720 A Vtrans = 3.499720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:08:46 Magnet Current, Imag = 349.9830 A Vtrans = 3.499830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:08:48 Magnet Current, Imag = 349.9370 A Vtrans = 3.499370 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:08:48 Magnet Current Measurement: Imag = 349.9585 +- 0.0195 A 11:08:48 Magnet current ramping to 400.0000 A... 11:09:11 Magnet Current, Imag = 399.9900 A Vtrans = 3.999900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:09:13 Magnet Current, Imag = 399.9830 A Vtrans = 3.999830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:09:15 Magnet Current, Imag = 399.9790 A Vtrans = 3.999790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:09:16 Magnet Current, Imag = 399.9790 A Vtrans = 3.999790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:09:16 Magnet Current Measurement: Imag = 399.9828 +- 0.0045 A 11:09:16 Magnetic Field Measurement Measuring the magnet strength... 11:09:16 Integrated Voltage Measurement... 11:09:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009484191 Vs 11:09:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009876481 Vs 11:09:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009476765 Vs 11:10:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009868017 Vs 11:10:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009499816 Vs 11:10:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009869158 Vs 11:10:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009486838 Vs 11:10:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009882984 Vs 11:10:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009680531 +- 0.000005028 Vs 11:10:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009680531 +- 0.000005028 Vs BL = 0.96805314 +- 0.00050281 Tm 11:10:50 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.96805 0.00050 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.96805 0.00050 0.96805 0.00000 11:10:50 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.96805 0.00050 SL = 0.9680531 +- 0.0005028 Tm^2/m^n 11:10:51 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9680531 +- 0.0005028 Tm^2/m^n 11:10:52 Magnet Current, Imag = 399.9830 A Vtrans = 3.999830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:10:54 Magnet Current, Imag = 399.9830 A Vtrans = 3.999830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:10:55 Magnet Current, Imag = 399.9850 A Vtrans = 3.999850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:10:57 Magnet Current, Imag = 399.9870 A Vtrans = 3.999870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:10:57 Magnet Current Measurement: Imag = 399.9845 +- 0.0017 A 11:10:57 Magnet current ramping to 450.0000 A... 11:11:20 Magnet Current, Imag = 449.9990 A Vtrans = 4.499990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:11:21 Magnet Current, Imag = 449.9840 A Vtrans = 4.499840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:11:23 Magnet Current, Imag = 450.0060 A Vtrans = 4.500060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:11:24 Magnet Current, Imag = 450.0210 A Vtrans = 4.500210 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:11:25 Magnet Current Measurement: Imag = 450.0025 +- 0.0133 A 11:11:25 Magnetic Field Measurement Measuring the magnet strength... 11:11:25 Integrated Voltage Measurement... 11:11:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010708057 Vs 11:11:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011095110 Vs 11:11:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010697599 Vs 11:12:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011100912 Vs 11:12:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010706451 Vs 11:12:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011090693 Vs 11:12:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010705529 Vs 11:12:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011080159 Vs 11:12:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010898064 +- 0.000003214 Vs 11:12:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.010898064 +- 0.000003214 Vs BL = 1.08980637 +- 0.00032138 Tm 11:12:58 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.08981 0.00032 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.08981 0.00032 1.08981 0.00000 11:12:58 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.08981 0.00032 SL = 1.0898064 +- 0.0003214 Tm^2/m^n 11:12:58 Magnet Strength Measurement Harmonic Number = 1 SL = 1.0898064 +- 0.0003214 Tm^2/m^n 11:12:59 Magnet Current, Imag = 450.0000 A Vtrans = 4.500000 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:13:01 Magnet Current, Imag = 450.0160 A Vtrans = 4.500160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:13:03 Magnet Current, Imag = 450.0140 A Vtrans = 4.500140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:13:04 Magnet Current, Imag = 450.0060 A Vtrans = 4.500060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:13:04 Magnet Current Measurement: Imag = 450.0090 +- 0.0064 A 11:13:04 Magnet current ramping to 500.0000 A... 11:13:28 Magnet Current, Imag = 500.0850 A Vtrans = 5.000850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:13:30 Magnet Current, Imag = 500.0860 A Vtrans = 5.000860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:13:31 Magnet Current, Imag = 500.0710 A Vtrans = 5.000710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:13:33 Magnet Current, Imag = 500.0630 A Vtrans = 5.000630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:13:33 Magnet Current Measurement: Imag = 500.0762 +- 0.0097 A 11:13:33 Magnetic Field Measurement Measuring the magnet strength... 11:13:33 Integrated Voltage Measurement... 11:13:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011904988 Vs 11:13:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012293587 Vs 11:14:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011879517 Vs 11:14:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012286626 Vs 11:14:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011899639 Vs 11:14:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012294977 Vs 11:14:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011908909 Vs 11:15:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012293184 Vs 11:15:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012095178 +- 0.000007114 Vs 11:15:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012095178 +- 0.000007114 Vs BL = 1.20951784 +- 0.00071139 Tm 11:15:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.20952 0.00071 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.20952 0.00071 1.20952 0.00000 11:15:04 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.20952 0.00071 SL = 1.2095178 +- 0.0007114 Tm^2/m^n 11:15:04 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2095178 +- 0.0007114 Tm^2/m^n 11:15:06 Magnet Current, Imag = 500.1030 A Vtrans = 5.001030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:15:07 Magnet Current, Imag = 500.0870 A Vtrans = 5.000870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:15:09 Magnet Current, Imag = 500.0930 A Vtrans = 5.000930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:15:10 Magnet Current, Imag = 500.0900 A Vtrans = 5.000900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:15:10 Magnet Current Measurement: Imag = 500.0933 +- 0.0060 A 11:15:10 Magnet current ramping to 525.0000 A... 11:15:27 Magnet Current, Imag = 525.1050 A Vtrans = 5.251050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:15:29 Magnet Current, Imag = 525.1160 A Vtrans = 5.251160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:15:30 Magnet Current, Imag = 525.0580 A Vtrans = 5.250580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:15:32 Magnet Current, Imag = 525.0860 A Vtrans = 5.250860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:15:32 Magnet Current Measurement: Imag = 525.0912 +- 0.0220 A 11:15:32 Magnetic Field Measurement Measuring the magnet strength... 11:15:32 Integrated Voltage Measurement... 11:15:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012499944 Vs 11:15:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012877538 Vs 11:16:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012482522 Vs 11:16:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012895342 Vs 11:16:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012486667 Vs 11:16:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012901246 Vs 11:16:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012492065 Vs 11:17:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012894953 Vs 11:17:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012691285 +- 0.000002454 Vs 11:17:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012691285 +- 0.000002454 Vs BL = 1.26912848 +- 0.00024543 Tm 11:17:03 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.26913 0.00025 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.26913 0.00025 1.26913 0.00000 11:17:03 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.26913 0.00025 SL = 1.2691285 +- 0.0002454 Tm^2/m^n 11:17:03 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2691285 +- 0.0002454 Tm^2/m^n 11:17:05 Magnet Current, Imag = 525.1140 A Vtrans = 5.251140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:17:06 Magnet Current, Imag = 525.0910 A Vtrans = 5.250910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:17:08 Magnet Current, Imag = 525.0970 A Vtrans = 5.250970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:17:10 Magnet Current, Imag = 525.1010 A Vtrans = 5.251010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:17:10 Magnet Current Measurement: Imag = 525.1008 +- 0.0084 A 11:17:10 Magnet current ramping to 550.0000 A... 11:17:25 Magnet Current, Imag = 550.0540 A Vtrans = 5.500540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:17:27 Magnet Current, Imag = 550.0610 A Vtrans = 5.500610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:17:29 Magnet Current, Imag = 550.0830 A Vtrans = 5.500830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:17:30 Magnet Current, Imag = 550.0760 A Vtrans = 5.500760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:17:30 Magnet Current Measurement: Imag = 550.0685 +- 0.0115 A 11:17:30 Magnetic Field Measurement Measuring the magnet strength... 11:17:30 Integrated Voltage Measurement... 11:17:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013086728 Vs 11:17:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013476010 Vs 11:18:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013084796 Vs 11:18:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013488983 Vs 11:18:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013068133 Vs 11:18:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013476410 Vs 11:18:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013087761 Vs 11:18:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013489085 Vs 11:18:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013282238 +- 0.000006324 Vs 11:18:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.013282238 +- 0.000006324 Vs BL = 1.32822381 +- 0.00063241 Tm 11:19:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.32822 0.00063 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.32822 0.00063 1.32822 0.00000 11:19:02 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.32822 0.00063 SL = 1.3282238 +- 0.0006324 Tm^2/m^n 11:19:02 Magnet Strength Measurement Harmonic Number = 1 SL = 1.3282238 +- 0.0006324 Tm^2/m^n 11:19:04 Magnet Current, Imag = 550.0810 A Vtrans = 5.500810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:19:05 Magnet Current, Imag = 550.0960 A Vtrans = 5.500960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:19:07 Magnet Current, Imag = 550.0830 A Vtrans = 5.500830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:19:08 Magnet Current, Imag = 550.0850 A Vtrans = 5.500850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:19:08 Magnet Current Measurement: Imag = 550.0862 +- 0.0058 A 11:19:08 Magnet current ramping to 575.0000 A... 11:19:24 Magnet Current, Imag = 575.1120 A Vtrans = 5.751120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:19:26 Magnet Current, Imag = 575.1190 A Vtrans = 5.751190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:19:27 Magnet Current, Imag = 575.1330 A Vtrans = 5.751330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:19:29 Magnet Current, Imag = 575.1030 A Vtrans = 5.751030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:19:29 Magnet Current Measurement: Imag = 575.1168 +- 0.0110 A 11:19:29 Magnetic Field Measurement Measuring the magnet strength... 11:19:29 Integrated Voltage Measurement... 11:19:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013657278 Vs 11:19:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014060949 Vs 11:20:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013669010 Vs 11:20:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014062953 Vs 11:20:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013667435 Vs 11:20:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014070454 Vs 11:20:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013688843 Vs 11:20:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014058210 Vs 11:20:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013866891 +- 0.000005234 Vs 11:20:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.013866891 +- 0.000005234 Vs BL = 1.38668914 +- 0.00052336 Tm 11:21:01 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.38669 0.00052 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.38669 0.00052 1.38669 0.00000 11:21:01 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.38669 0.00052 SL = 1.3866891 +- 0.0005234 Tm^2/m^n 11:21:01 Magnet Strength Measurement Harmonic Number = 1 SL = 1.3866891 +- 0.0005234 Tm^2/m^n 11:21:02 Magnet Current, Imag = 575.1220 A Vtrans = 5.751220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:21:04 Magnet Current, Imag = 575.1290 A Vtrans = 5.751290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:21:05 Magnet Current, Imag = 575.1210 A Vtrans = 5.751210 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:21:07 Magnet Current, Imag = 575.1120 A Vtrans = 5.751120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:21:07 Magnet Current Measurement: Imag = 575.1210 +- 0.0060 A 11:21:07 Magnet current ramping to 600.0000 A... 11:21:23 Magnet Current, Imag = 600.1390 A Vtrans = 6.001390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:21:24 Magnet Current, Imag = 600.1230 A Vtrans = 6.001230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:21:26 Magnet Current, Imag = 600.0920 A Vtrans = 6.000920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:21:27 Magnet Current, Imag = 600.1440 A Vtrans = 6.001440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:21:27 Magnet Current Measurement: Imag = 600.1245 +- 0.0203 A 11:21:27 Magnetic Field Measurement Measuring the magnet strength... 11:21:27 Integrated Voltage Measurement... 11:21:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014250823 Vs 11:21:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014651852 Vs 11:22:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014255043 Vs 11:22:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014636006 Vs 11:22:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014253523 Vs 11:22:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014655356 Vs 11:22:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014266290 Vs 11:22:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014651751 Vs 11:22:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014452580 +- 0.000004906 Vs 11:22:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014452580 +- 0.000004906 Vs BL = 1.44525804 +- 0.00049055 Tm 11:23:00 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.44526 0.00049 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.44526 0.00049 1.44526 0.00000 11:23:00 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.44526 0.00049 SL = 1.4452580 +- 0.0004906 Tm^2/m^n 11:23:00 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4452580 +- 0.0004906 Tm^2/m^n 11:23:02 Magnet Current, Imag = 600.1520 A Vtrans = 6.001520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:23:03 Magnet Current, Imag = 600.0970 A Vtrans = 6.000970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:23:05 Magnet Current, Imag = 600.1060 A Vtrans = 6.001060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:23:07 Magnet Current, Imag = 600.1060 A Vtrans = 6.001060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:23:07 Magnet Current Measurement: Imag = 600.1153 +- 0.0215 A 11:23:07 Magnet current ramping to 625.0000 A... 11:23:22 Magnet Current, Imag = 625.1640 A Vtrans = 6.251640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:23:24 Magnet Current, Imag = 625.1110 A Vtrans = 6.251110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:23:25 Magnet Current, Imag = 625.1510 A Vtrans = 6.251510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:23:27 Magnet Current, Imag = 625.1790 A Vtrans = 6.251790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:23:27 Magnet Current Measurement: Imag = 625.1513 +- 0.0253 A 11:23:27 Magnetic Field Measurement Measuring the magnet strength... 11:23:27 Integrated Voltage Measurement... 11:23:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014799137 Vs 11:23:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015190325 Vs 11:24:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014812081 Vs 11:24:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015193276 Vs 11:24:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014802979 Vs 11:24:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015201013 Vs 11:24:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014798989 Vs 11:24:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015198028 Vs 11:24:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014999478 +- 0.000003164 Vs 11:24:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014999478 +- 0.000003164 Vs BL = 1.49994783 +- 0.00031645 Tm 11:25:00 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.49995 0.00032 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.49995 0.00032 1.49995 0.00000 11:25:00 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.49995 0.00032 SL = 1.4999478 +- 0.0003164 Tm^2/m^n 11:25:00 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4999478 +- 0.0003164 Tm^2/m^n 11:25:01 Magnet Current, Imag = 625.1470 A Vtrans = 6.251470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:25:03 Magnet Current, Imag = 625.1510 A Vtrans = 6.251510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:25:04 Magnet Current, Imag = 625.1470 A Vtrans = 6.251470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:25:06 Magnet Current, Imag = 625.1590 A Vtrans = 6.251590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:25:06 Magnet Current Measurement: Imag = 625.1510 +- 0.0049 A 11:25:06 Magnet current ramping to 650.0000 A... 11:25:22 Magnet Current, Imag = 650.2160 A Vtrans = 6.502160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:25:23 Magnet Current, Imag = 650.1820 A Vtrans = 6.501820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:25:25 Magnet Current, Imag = 650.1990 A Vtrans = 6.501990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:25:26 Magnet Current, Imag = 650.2220 A Vtrans = 6.502220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:25:26 Magnet Current Measurement: Imag = 650.2047 +- 0.0156 A 11:25:26 Magnetic Field Measurement Measuring the magnet strength... 11:25:26 Integrated Voltage Measurement... 11:25:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015340990 Vs 11:25:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015723637 Vs 11:26:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015329821 Vs 11:26:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015726918 Vs 11:26:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015328893 Vs 11:26:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015731527 Vs 11:26:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015342049 Vs 11:26:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015728188 Vs 11:26:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015531503 +- 0.000002511 Vs 11:26:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015531503 +- 0.000002511 Vs BL = 1.55315029 +- 0.00025108 Tm 11:27:00 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.55315 0.00025 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.55315 0.00025 1.55315 0.00000 11:27:00 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.55315 0.00025 SL = 1.5531503 +- 0.0002511 Tm^2/m^n 11:27:00 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5531503 +- 0.0002511 Tm^2/m^n 11:27:01 Magnet Current, Imag = 650.1590 A Vtrans = 6.501590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:27:03 Magnet Current, Imag = 650.1170 A Vtrans = 6.501170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:27:05 Magnet Current, Imag = 650.2160 A Vtrans = 6.502160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:27:07 Magnet Current, Imag = 650.1960 A Vtrans = 6.501960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:27:07 Magnet Current Measurement: Imag = 650.1720 +- 0.0378 A 11:27:07 Magnet current ramping to 675.0000 A... 11:27:23 Magnet Current, Imag = 675.2180 A Vtrans = 6.752180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:27:24 Magnet Current, Imag = 675.2210 A Vtrans = 6.752210 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:27:26 Magnet Current, Imag = 675.2080 A Vtrans = 6.752080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:27:27 Magnet Current, Imag = 675.2190 A Vtrans = 6.752190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:27:27 Magnet Current Measurement: Imag = 675.2165 +- 0.0050 A 11:27:27 Magnetic Field Measurement Measuring the magnet strength... 11:27:27 Integrated Voltage Measurement... 11:27:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015842169 Vs 11:27:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016238671 Vs 11:28:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015830575 Vs 11:28:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016225335 Vs 11:28:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015833671 Vs 11:28:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016235949 Vs 11:28:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015841024 Vs 11:28:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016232696 Vs 11:28:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016035011 +- 0.000004542 Vs 11:28:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016035011 +- 0.000004542 Vs BL = 1.60350113 +- 0.00045417 Tm 11:28:59 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.60350 0.00045 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.60350 0.00045 1.60350 0.00000 11:28:59 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.60350 0.00045 SL = 1.6035011 +- 0.0004542 Tm^2/m^n 11:28:59 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6035011 +- 0.0004542 Tm^2/m^n 11:29:01 Magnet Current, Imag = 675.2310 A Vtrans = 6.752310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:29:02 Magnet Current, Imag = 675.2730 A Vtrans = 6.752730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:29:04 Magnet Current, Imag = 675.2480 A Vtrans = 6.752480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:29:05 Magnet Current, Imag = 675.2250 A Vtrans = 6.752250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:29:05 Magnet Current Measurement: Imag = 675.2442 +- 0.0186 A 11:29:05 Magnet current ramping to 700.0000 A... 11:29:21 Magnet Current, Imag = 700.2440 A Vtrans = 7.002440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:29:23 Magnet Current, Imag = 700.2470 A Vtrans = 7.002470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:29:24 Magnet Current, Imag = 700.1860 A Vtrans = 7.001860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:29:26 Magnet Current, Imag = 700.2290 A Vtrans = 7.002290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:29:26 Magnet Current Measurement: Imag = 700.2265 +- 0.0244 A 11:29:26 Magnetic Field Measurement Measuring the magnet strength... 11:29:26 Integrated Voltage Measurement... 11:29:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016296158 Vs 11:29:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016689872 Vs 11:30:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016319087 Vs 11:30:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016700753 Vs 11:30:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016307050 Vs 11:30:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016702019 Vs 11:30:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016304951 Vs 11:30:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016695807 Vs 11:30:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016501962 +- 0.000006175 Vs 11:30:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016501962 +- 0.000006175 Vs BL = 1.65019622 +- 0.00061747 Tm 11:30:57 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.65020 0.00062 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.65020 0.00062 1.65020 0.00000 11:30:57 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.65020 0.00062 SL = 1.6501962 +- 0.0006175 Tm^2/m^n 11:30:57 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6501962 +- 0.0006175 Tm^2/m^n 11:30:59 Magnet Current, Imag = 700.1970 A Vtrans = 7.001970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:31:00 Magnet Current, Imag = 700.2230 A Vtrans = 7.002230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:31:02 Magnet Current, Imag = 700.1810 A Vtrans = 7.001810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:31:03 Magnet Current, Imag = 700.2160 A Vtrans = 7.002160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:31:03 Magnet Current Measurement: Imag = 700.2043 +- 0.0165 A 11:31:04 Magnet current ramping to 650.0000 A... 11:31:27 Magnet Current, Imag = 650.1760 A Vtrans = 6.501760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:31:28 Magnet Current, Imag = 650.1800 A Vtrans = 6.501800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:31:30 Magnet Current, Imag = 650.1550 A Vtrans = 6.501550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:31:31 Magnet Current, Imag = 650.1810 A Vtrans = 6.501810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:31:31 Magnet Current Measurement: Imag = 650.1730 +- 0.0106 A 11:31:31 Magnetic Field Measurement Measuring the magnet strength... 11:31:31 Integrated Voltage Measurement... 11:31:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015403269 Vs 11:31:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015794237 Vs 11:32:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015380147 Vs 11:32:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015800371 Vs 11:32:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015401419 Vs 11:32:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015789671 Vs 11:32:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015407193 Vs 11:33:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015790493 Vs 11:33:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015595850 +- 0.000003491 Vs 11:33:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015595850 +- 0.000003491 Vs BL = 1.55958500 +- 0.00034908 Tm 11:33:03 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.55958 0.00035 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.55958 0.00035 1.55958 0.00000 11:33:03 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.55958 0.00035 SL = 1.5595850 +- 0.0003491 Tm^2/m^n 11:33:03 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5595850 +- 0.0003491 Tm^2/m^n 11:33:04 Magnet Current, Imag = 650.1430 A Vtrans = 6.501430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:33:06 Magnet Current, Imag = 650.2270 A Vtrans = 6.502270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:33:07 Magnet Current, Imag = 650.1550 A Vtrans = 6.501550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:33:09 Magnet Current, Imag = 650.2130 A Vtrans = 6.502130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:33:09 Magnet Current Measurement: Imag = 650.1845 +- 0.0361 A 11:33:09 Magnet current ramping to 600.0000 A... 11:33:34 Magnet Current, Imag = 600.1170 A Vtrans = 6.001170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:33:35 Magnet Current, Imag = 600.1340 A Vtrans = 6.001340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:33:37 Magnet Current, Imag = 600.1350 A Vtrans = 6.001350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:33:38 Magnet Current, Imag = 600.1060 A Vtrans = 6.001060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:33:38 Magnet Current Measurement: Imag = 600.1230 +- 0.0121 A 11:33:38 Magnetic Field Measurement Measuring the magnet strength... 11:33:38 Integrated Voltage Measurement... 11:33:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014326722 Vs 11:34:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014684574 Vs 11:34:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014309994 Vs 11:34:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014704230 Vs 11:34:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014318072 Vs 11:34:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014719691 Vs 11:34:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014329182 Vs 11:35:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014698346 Vs 11:35:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014511351 +- 0.000005316 Vs 11:35:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014511351 +- 0.000005316 Vs BL = 1.45113514 +- 0.00053157 Tm 11:35:10 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.45114 0.00053 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.45114 0.00053 1.45114 0.00000 11:35:10 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.45114 0.00053 SL = 1.4511351 +- 0.0005316 Tm^2/m^n 11:35:10 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4511351 +- 0.0005316 Tm^2/m^n 11:35:12 Magnet Current, Imag = 600.1570 A Vtrans = 6.001570 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:35:13 Magnet Current, Imag = 600.1020 A Vtrans = 6.001020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:35:15 Magnet Current, Imag = 600.0860 A Vtrans = 6.000860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:35:17 Magnet Current, Imag = 600.0900 A Vtrans = 6.000900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:35:17 Magnet Current Measurement: Imag = 600.1087 +- 0.0285 A 11:35:17 Magnet current ramping to 550.0000 A... 11:35:40 Magnet Current, Imag = 550.0820 A Vtrans = 5.500820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:35:41 Magnet Current, Imag = 550.0520 A Vtrans = 5.500520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:35:43 Magnet Current, Imag = 550.0560 A Vtrans = 5.500560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:35:44 Magnet Current, Imag = 550.0540 A Vtrans = 5.500540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:35:44 Magnet Current Measurement: Imag = 550.0610 +- 0.0122 A 11:35:44 Magnetic Field Measurement Measuring the magnet strength... 11:35:44 Integrated Voltage Measurement... 11:35:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013143254 Vs 11:36:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013524948 Vs 11:36:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013144253 Vs 11:36:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013532667 Vs 11:36:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013140727 Vs 11:36:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013531936 Vs 11:37:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013143169 Vs 11:37:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013547079 Vs 11:37:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013338504 +- 0.000004121 Vs 11:37:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.013338504 +- 0.000004121 Vs BL = 1.33385041 +- 0.00041211 Tm 11:37:17 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.33385 0.00041 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.33385 0.00041 1.33385 0.00000 11:37:17 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.33385 0.00041 SL = 1.3338504 +- 0.0004121 Tm^2/m^n 11:37:17 Magnet Strength Measurement Harmonic Number = 1 SL = 1.3338504 +- 0.0004121 Tm^2/m^n 11:37:18 Magnet Current, Imag = 550.0580 A Vtrans = 5.500580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:37:20 Magnet Current, Imag = 550.0530 A Vtrans = 5.500530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:37:21 Magnet Current, Imag = 550.0660 A Vtrans = 5.500660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:37:23 Magnet Current, Imag = 550.0690 A Vtrans = 5.500690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:37:23 Magnet Current Measurement: Imag = 550.0615 +- 0.0063 A 11:37:23 Magnet current ramping to 500.0000 A... 11:37:46 Magnet Current, Imag = 500.0570 A Vtrans = 5.000570 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:37:48 Magnet Current, Imag = 500.0720 A Vtrans = 5.000720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:37:49 Magnet Current, Imag = 500.0710 A Vtrans = 5.000710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:37:51 Magnet Current, Imag = 500.0710 A Vtrans = 5.000710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:37:51 Magnet Current Measurement: Imag = 500.0677 +- 0.0062 A 11:37:51 Magnetic Field Measurement Measuring the magnet strength... 11:37:51 Integrated Voltage Measurement... 11:38:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011950492 Vs 11:38:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012350791 Vs 11:38:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011940170 Vs 11:38:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012344058 Vs 11:38:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011953725 Vs 11:38:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012345045 Vs 11:39:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011934866 Vs 11:39:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012349243 Vs 11:39:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012146049 +- 0.000003989 Vs 11:39:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012146049 +- 0.000003989 Vs BL = 1.21460488 +- 0.00039894 Tm 11:39:23 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.21460 0.00040 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.21460 0.00040 1.21460 0.00000 11:39:24 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.21460 0.00040 SL = 1.2146049 +- 0.0003989 Tm^2/m^n 11:39:24 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2146049 +- 0.0003989 Tm^2/m^n 11:39:25 Magnet Current, Imag = 500.0790 A Vtrans = 5.000790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:39:27 Magnet Current, Imag = 500.0420 A Vtrans = 5.000420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:39:28 Magnet Current, Imag = 500.0580 A Vtrans = 5.000580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:39:30 Magnet Current, Imag = 500.0830 A Vtrans = 5.000830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:39:30 Magnet Current Measurement: Imag = 500.0655 +- 0.0166 A 11:39:30 Magnet current ramping to 450.0000 A... 11:39:53 Magnet Current, Imag = 450.0020 A Vtrans = 4.500020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:39:54 Magnet Current, Imag = 449.9850 A Vtrans = 4.499850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:39:56 Magnet Current, Imag = 450.0170 A Vtrans = 4.500170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:39:58 Magnet Current, Imag = 450.0230 A Vtrans = 4.500230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:39:58 Magnet Current Measurement: Imag = 450.0068 +- 0.0147 A 11:39:58 Magnetic Field Measurement Measuring the magnet strength... 11:39:58 Integrated Voltage Measurement... 11:40:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010747655 Vs 11:40:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011143679 Vs 11:40:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010752353 Vs 11:40:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011139437 Vs 11:40:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010747312 Vs 11:41:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011133562 Vs 11:41:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010731316 Vs 11:41:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011134039 Vs 11:41:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010941169 +- 0.000005367 Vs 11:41:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.010941169 +- 0.000005367 Vs BL = 1.09411690 +- 0.00053666 Tm 11:41:29 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.09412 0.00054 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.09412 0.00054 1.09412 0.00000 11:41:29 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.09412 0.00054 SL = 1.0941169 +- 0.0005367 Tm^2/m^n 11:41:29 Magnet Strength Measurement Harmonic Number = 1 SL = 1.0941169 +- 0.0005367 Tm^2/m^n 11:41:31 Magnet Current, Imag = 449.9850 A Vtrans = 4.499850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:41:32 Magnet Current, Imag = 449.9900 A Vtrans = 4.499900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:41:34 Magnet Current, Imag = 450.0260 A Vtrans = 4.500260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:41:35 Magnet Current, Imag = 450.0050 A Vtrans = 4.500050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:41:35 Magnet Current Measurement: Imag = 450.0015 +- 0.0159 A 11:41:35 Magnet current ramping to 400.0000 A... 11:41:59 Magnet Current, Imag = 399.9780 A Vtrans = 3.999780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:42:01 Magnet Current, Imag = 399.9620 A Vtrans = 3.999620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:42:02 Magnet Current, Imag = 399.9560 A Vtrans = 3.999560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:42:04 Magnet Current, Imag = 399.9530 A Vtrans = 3.999530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:42:04 Magnet Current Measurement: Imag = 399.9622 +- 0.0097 A 11:42:04 Magnetic Field Measurement Measuring the magnet strength... 11:42:04 Integrated Voltage Measurement... 11:42:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009532457 Vs 11:42:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009922616 Vs 11:42:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009532029 Vs 11:42:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009934001 Vs 11:43:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009517251 Vs 11:43:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009929577 Vs 11:43:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009546723 Vs 11:43:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009916449 Vs 11:43:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009728888 +- 0.000003745 Vs 11:43:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009728888 +- 0.000003745 Vs BL = 0.97288878 +- 0.00037453 Tm 11:43:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.97289 0.00037 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.97289 0.00037 0.97289 0.00000 11:43:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.97289 0.00037 SL = 0.9728888 +- 0.0003745 Tm^2/m^n 11:43:38 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9728888 +- 0.0003745 Tm^2/m^n 11:43:40 Magnet Current, Imag = 399.9540 A Vtrans = 3.999540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:43:42 Magnet Current, Imag = 399.9250 A Vtrans = 3.999250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:43:43 Magnet Current, Imag = 399.9430 A Vtrans = 3.999430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:43:45 Magnet Current, Imag = 399.9350 A Vtrans = 3.999350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:43:45 Magnet Current Measurement: Imag = 399.9393 +- 0.0106 A 11:44:15 Magnet current ramping to 0.0000 A...