SLAC Magnetic Measurements Date: 11-13-2002 Time: 10:04:44 Project: spear3 Magnet Type: gdipole Magnet Name: test Serial Number: Run Number: 1 Measurement Device: stretched wire Operator: sa Comment: BL vs I, trim 109D33 Test Currents (A): -12.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 10:04:52 Initial Zero Current Measurement, Imag_zero = 0.0000 A 10:05:21 Magnet current ramping to -12.0000 A... 10:06:12 Magnet Current, Imag = -12.0862 A Vtrans = -0.120862 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:06:14 Magnet Current, Imag = -12.0859 A Vtrans = -0.120859 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:06:16 Magnet Current, Imag = -12.0856 A Vtrans = -0.120856 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:06:18 Magnet Current, Imag = -12.0853 A Vtrans = -0.120853 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:06:18 Magnet Current Measurement: Imag = -12.0858 +- 0.0004 A 10:06:18 Magnetic Field Measurement Measuring the magnet strength... 10:06:18 Integrated Voltage Measurement... 10:06:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000270809 Vs 10:06:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000309623 Vs 10:06:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000269671 Vs 10:07:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000309957 Vs 10:07:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000269400 Vs 10:07:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000309276 Vs 10:07:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000268753 Vs 10:07:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000308947 Vs 10:07:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000289554 +- 0.000000512 Vs 10:07:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000289554 +- 0.000000512 Vs BL = -0.02895544 +- 0.00005120 Tm 10:07:50 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02896 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.02896 0.00005 -0.02896 0.00000 10:07:50 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02896 0.00005 SL = -0.0289554 +- 0.0000512 Tm^2/m^n 10:07:50 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0289554 +- 0.0000512 Tm^2/m^n 10:07:52 Magnet Current, Imag = -12.0761 A Vtrans = -0.120761 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:07:54 Magnet Current, Imag = -12.0760 A Vtrans = -0.120760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:07:56 Magnet Current, Imag = -12.0759 A Vtrans = -0.120759 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:07:58 Magnet Current, Imag = -12.0758 A Vtrans = -0.120758 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:07:58 Magnet Current Measurement: Imag = -12.0759 +- 0.0001 A 10:07:58 Magnet current ramping to -10.0000 A... 10:08:14 Magnet Current, Imag = -10.0300 A Vtrans = -0.100300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:08:16 Magnet Current, Imag = -10.0300 A Vtrans = -0.100300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:08:18 Magnet Current, Imag = -10.0300 A Vtrans = -0.100300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:08:20 Magnet Current, Imag = -10.0300 A Vtrans = -0.100300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:08:20 Magnet Current Measurement: Imag = -10.0300 +- 0.0000 A 10:08:20 Magnetic Field Measurement Measuring the magnet strength... 10:08:20 Integrated Voltage Measurement... 10:08:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000220510 Vs 10:08:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000256984 Vs 10:08:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000221565 Vs 10:09:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000257888 Vs 10:09:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000221313 Vs 10:09:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000257000 Vs 10:09:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000221224 Vs 10:09:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000256490 Vs 10:09:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000239122 +- 0.000000380 Vs 10:09:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000239122 +- 0.000000380 Vs BL = -0.02391218 +- 0.00003800 Tm 10:09:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02391 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.02391 0.00004 -0.02391 0.00000 10:09:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02391 0.00004 SL = -0.0239122 +- 0.0000380 Tm^2/m^n 10:09:52 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0239122 +- 0.0000380 Tm^2/m^n 10:09:54 Magnet Current, Imag = -10.0299 A Vtrans = -0.100299 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:09:56 Magnet Current, Imag = -10.0299 A Vtrans = -0.100299 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:09:58 Magnet Current, Imag = -10.0299 A Vtrans = -0.100299 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:10:00 Magnet Current, Imag = -10.0298 A Vtrans = -0.100298 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:10:00 Magnet Current Measurement: Imag = -10.0299 +- 0.0000 A 10:10:00 Magnet current ramping to -8.0000 A... 10:10:16 Magnet Current, Imag = -8.0007 A Vtrans = -0.080007 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:10:18 Magnet Current, Imag = -8.0008 A Vtrans = -0.080007 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:10:20 Magnet Current, Imag = -8.0008 A Vtrans = -0.080007 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:10:21 Magnet Current, Imag = -8.0008 A Vtrans = -0.080008 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:10:22 Magnet Current Measurement: Imag = -8.0008 +- 0.0000 A 10:10:22 Magnetic Field Measurement Measuring the magnet strength... 10:10:22 Integrated Voltage Measurement... 10:10:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000171234 Vs 10:10:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000205599 Vs 10:10:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000171795 Vs 10:11:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000204673 Vs 10:11:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000171736 Vs 10:11:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000205257 Vs 10:11:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000171659 Vs 10:11:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000204595 Vs 10:11:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000188319 +- 0.000000146 Vs 10:11:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000188319 +- 0.000000146 Vs BL = -0.01883186 +- 0.00001456 Tm 10:11:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01883 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.01883 0.00001 -0.01883 0.00000 10:11:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01883 0.00001 SL = -0.0188319 +- 0.0000146 Tm^2/m^n 10:11:54 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0188319 +- 0.0000146 Tm^2/m^n 10:11:56 Magnet Current, Imag = -8.0018 A Vtrans = -0.080018 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:11:58 Magnet Current, Imag = -8.0018 A Vtrans = -0.080018 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:12:00 Magnet Current, Imag = -8.0018 A Vtrans = -0.080018 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:12:02 Magnet Current, Imag = -8.0019 A Vtrans = -0.080019 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:12:02 Magnet Current Measurement: Imag = -8.0018 +- 0.0000 A 10:12:02 Magnet current ramping to -6.0000 A... 10:12:18 Magnet Current, Imag = -5.9714 A Vtrans = -0.059714 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:12:20 Magnet Current, Imag = -5.9715 A Vtrans = -0.059715 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:12:21 Magnet Current, Imag = -5.9715 A Vtrans = -0.059715 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:12:23 Magnet Current, Imag = -5.9716 A Vtrans = -0.059716 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:12:23 Magnet Current Measurement: Imag = -5.9715 +- 0.0001 A 10:12:23 Magnetic Field Measurement Measuring the magnet strength... 10:12:23 Integrated Voltage Measurement... 10:12:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000120557 Vs 10:12:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000153033 Vs 10:12:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000121827 Vs 10:13:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000152669 Vs 10:13:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000122317 Vs 10:13:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000153765 Vs 10:13:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000121886 Vs 10:13:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000153075 Vs 10:13:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000137391 +- 0.000000449 Vs 10:13:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000137391 +- 0.000000449 Vs BL = -0.01373912 +- 0.00004489 Tm 10:13:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01374 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.01374 0.00004 -0.01374 0.00000 10:13:56 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01374 0.00004 SL = -0.0137391 +- 0.0000449 Tm^2/m^n 10:13:56 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0137391 +- 0.0000449 Tm^2/m^n 10:13:58 Magnet Current, Imag = -5.9724 A Vtrans = -0.059724 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:13:59 Magnet Current, Imag = -5.9725 A Vtrans = -0.059725 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:14:01 Magnet Current, Imag = -5.9724 A Vtrans = -0.059724 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:14:03 Magnet Current, Imag = -5.9724 A Vtrans = -0.059724 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:14:03 Magnet Current Measurement: Imag = -5.9724 +- 0.0000 A 10:14:03 Magnet current ramping to -4.0000 A... 10:14:19 Magnet Current, Imag = -3.9419 A Vtrans = -0.039419 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:14:21 Magnet Current, Imag = -3.9420 A Vtrans = -0.039420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:14:23 Magnet Current, Imag = -3.9420 A Vtrans = -0.039420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:14:25 Magnet Current, Imag = -3.9421 A Vtrans = -0.039421 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:14:25 Magnet Current Measurement: Imag = -3.9420 +- 0.0000 A 10:14:25 Magnetic Field Measurement Measuring the magnet strength... 10:14:25 Integrated Voltage Measurement... 10:14:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000070510 Vs 10:14:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000101144 Vs 10:15:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000070756 Vs 10:15:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000100648 Vs 10:15:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000072237 Vs 10:15:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000099541 Vs 10:15:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000072860 Vs 10:15:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000100251 Vs 10:15:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000085993 +- 0.000000331 Vs 10:15:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000085993 +- 0.000000331 Vs BL = -0.00859932 +- 0.00003314 Tm 10:15:58 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00860 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00860 0.00003 -0.00860 0.00000 10:15:58 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00860 0.00003 SL = -0.0085993 +- 0.0000331 Tm^2/m^n 10:15:58 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0085993 +- 0.0000331 Tm^2/m^n 10:16:00 Magnet Current, Imag = -3.9427 A Vtrans = -0.039427 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:16:02 Magnet Current, Imag = -3.9427 A Vtrans = -0.039427 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:16:04 Magnet Current, Imag = -3.9427 A Vtrans = -0.039427 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:16:06 Magnet Current, Imag = -3.9427 A Vtrans = -0.039427 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:16:06 Magnet Current Measurement: Imag = -3.9427 +- 0.0000 A 10:16:06 Magnet current ramping to -2.0000 A... 10:16:22 Magnet Current, Imag = -1.9123 A Vtrans = -0.019123 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:16:24 Magnet Current, Imag = -1.9123 A Vtrans = -0.019123 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:16:26 Magnet Current, Imag = -1.9123 A Vtrans = -0.019123 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:16:28 Magnet Current, Imag = -1.9124 A Vtrans = -0.019124 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:16:28 Magnet Current Measurement: Imag = -1.9123 +- 0.0000 A 10:16:28 Magnetic Field Measurement Measuring the magnet strength... 10:16:28 Integrated Voltage Measurement... 10:16:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000020323 Vs 10:16:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000047793 Vs 10:17:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000021103 Vs 10:17:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000049350 Vs 10:17:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000019635 Vs 10:17:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000049265 Vs 10:17:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000020603 Vs 10:17:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000048606 Vs 10:17:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000034585 +- 0.000000421 Vs 10:17:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000034585 +- 0.000000421 Vs BL = -0.00345848 +- 0.00004207 Tm 10:18:00 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00346 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00346 0.00004 -0.00346 0.00000 10:18:00 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00346 0.00004 SL = -0.0034585 +- 0.0000421 Tm^2/m^n 10:18:00 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0034585 +- 0.0000421 Tm^2/m^n 10:18:02 Magnet Current, Imag = -1.9126 A Vtrans = -0.019126 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:18:04 Magnet Current, Imag = -1.9126 A Vtrans = -0.019126 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:18:06 Magnet Current, Imag = -1.9126 A Vtrans = -0.019126 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:18:07 Magnet Current, Imag = -1.9126 A Vtrans = -0.019126 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:18:08 Magnet Current Measurement: Imag = -1.9126 +- 0.0000 A 10:18:08 Magnet current ramping to 0.0000 A... 10:18:24 Magnet Current, Imag = 0.1196 A Vtrans = 0.001196 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:18:26 Magnet Current, Imag = 0.1196 A Vtrans = 0.001196 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:18:28 Magnet Current, Imag = 0.1196 A Vtrans = 0.001196 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:18:30 Magnet Current, Imag = 0.1196 A Vtrans = 0.001196 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:18:30 Magnet Current Measurement: Imag = 0.1196 +- 0.0000 A 10:18:30 Magnetic Field Measurement Measuring the magnet strength... 10:18:30 Integrated Voltage Measurement... 10:18:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000030315 Vs 10:18:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000003580 Vs 10:19:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000028441 Vs 10:19:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000003724 Vs 10:19:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000029401 Vs 10:19:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000004299 Vs 10:19:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000030080 Vs 10:19:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000004591 Vs 10:19:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000016804 +- 0.000000454 Vs 10:19:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000016804 +- 0.000000454 Vs BL = 0.00168039 +- 0.00004543 Tm 10:20:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00168 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00168 0.00005 0.00168 0.00000 10:20:02 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00168 0.00005 SL = 0.0016804 +- 0.0000454 Tm^2/m^n 10:20:02 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0016804 +- 0.0000454 Tm^2/m^n 10:20:04 Magnet Current, Imag = 0.1195 A Vtrans = 0.001195 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:20:06 Magnet Current, Imag = 0.1195 A Vtrans = 0.001195 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:20:08 Magnet Current, Imag = 0.1195 A Vtrans = 0.001195 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:20:10 Magnet Current, Imag = 0.1195 A Vtrans = 0.001195 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:20:10 Magnet Current Measurement: Imag = 0.1195 +- 0.0000 A 10:20:10 Magnet current ramping to 2.0000 A... 10:20:26 Magnet Current, Imag = 2.1514 A Vtrans = 0.021514 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:20:28 Magnet Current, Imag = 2.1513 A Vtrans = 0.021513 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:20:30 Magnet Current, Imag = 2.1514 A Vtrans = 0.021514 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:20:31 Magnet Current, Imag = 2.1513 A Vtrans = 0.021513 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:20:32 Magnet Current Measurement: Imag = 2.1514 +- 0.0001 A 10:20:32 Magnetic Field Measurement Measuring the magnet strength... 10:20:32 Integrated Voltage Measurement... 10:20:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000081047 Vs 10:20:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000056907 Vs 10:21:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000080033 Vs 10:21:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000055638 Vs 10:21:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000080689 Vs 10:21:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000056180 Vs 10:21:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000080093 Vs 10:22:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000056775 Vs 10:22:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000068420 +- 0.000000404 Vs 10:22:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000068420 +- 0.000000404 Vs BL = 0.00684204 +- 0.00004038 Tm 10:22:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00684 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00684 0.00004 0.00684 0.00000 10:22:04 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00684 0.00004 SL = 0.0068420 +- 0.0000404 Tm^2/m^n 10:22:04 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0068420 +- 0.0000404 Tm^2/m^n 10:22:06 Magnet Current, Imag = 2.1513 A Vtrans = 0.021513 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:22:07 Magnet Current, Imag = 2.1512 A Vtrans = 0.021512 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:22:09 Magnet Current, Imag = 2.1512 A Vtrans = 0.021512 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:22:11 Magnet Current, Imag = 2.1512 A Vtrans = 0.021512 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:22:11 Magnet Current Measurement: Imag = 2.1512 +- 0.0000 A 10:22:11 Magnet current ramping to 4.0000 A... 10:22:27 Magnet Current, Imag = 4.1826 A Vtrans = 0.041826 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:22:29 Magnet Current, Imag = 4.1826 A Vtrans = 0.041826 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:22:31 Magnet Current, Imag = 4.1825 A Vtrans = 0.041825 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:22:33 Magnet Current, Imag = 4.1825 A Vtrans = 0.041825 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:22:33 Magnet Current Measurement: Imag = 4.1825 +- 0.0000 A 10:22:33 Magnetic Field Measurement Measuring the magnet strength... 10:22:33 Integrated Voltage Measurement... 10:22:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000131643 Vs 10:22:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000109556 Vs 10:23:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000130865 Vs 10:23:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000109383 Vs 10:23:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000131239 Vs 10:23:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000110209 Vs 10:23:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000130941 Vs 10:24:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000108746 Vs 10:24:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000120323 +- 0.000000356 Vs 10:24:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000120323 +- 0.000000356 Vs BL = 0.01203226 +- 0.00003560 Tm 10:24:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.01203 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.01203 0.00004 0.01203 0.00000 10:24:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.01203 0.00004 SL = 0.0120323 +- 0.0000356 Tm^2/m^n 10:24:05 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0120323 +- 0.0000356 Tm^2/m^n 10:24:07 Magnet Current, Imag = 4.1820 A Vtrans = 0.041820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:24:09 Magnet Current, Imag = 4.1819 A Vtrans = 0.041819 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:24:11 Magnet Current, Imag = 4.1819 A Vtrans = 0.041819 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:24:13 Magnet Current, Imag = 4.1820 A Vtrans = 0.041820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:24:13 Magnet Current Measurement: Imag = 4.1819 +- 0.0000 A 10:24:13 Magnet current ramping to 6.0000 A... 10:24:29 Magnet Current, Imag = 6.2131 A Vtrans = 0.062131 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:24:31 Magnet Current, Imag = 6.2129 A Vtrans = 0.062129 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:24:33 Magnet Current, Imag = 6.2129 A Vtrans = 0.062129 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:24:35 Magnet Current, Imag = 6.2128 A Vtrans = 0.062128 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:24:35 Magnet Current Measurement: Imag = 6.2129 +- 0.0001 A 10:24:35 Magnetic Field Measurement Measuring the magnet strength... 10:24:35 Integrated Voltage Measurement... 10:24:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000182279 Vs 10:24:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000161173 Vs 10:25:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000182287 Vs 10:25:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000161987 Vs 10:25:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000182118 Vs 10:25:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000162273 Vs 10:25:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000181314 Vs 10:26:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000163258 Vs 10:26:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000172086 +- 0.000000215 Vs 10:26:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000172086 +- 0.000000215 Vs BL = 0.01720861 +- 0.00002146 Tm 10:26:07 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.01721 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.01721 0.00002 0.01721 0.00000 10:26:07 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.01721 0.00002 SL = 0.0172086 +- 0.0000215 Tm^2/m^n 10:26:07 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0172086 +- 0.0000215 Tm^2/m^n 10:26:09 Magnet Current, Imag = 6.2115 A Vtrans = 0.062115 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:26:11 Magnet Current, Imag = 6.2114 A Vtrans = 0.062114 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:26:13 Magnet Current, Imag = 6.2114 A Vtrans = 0.062114 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:26:15 Magnet Current, Imag = 6.2115 A Vtrans = 0.062115 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:26:15 Magnet Current Measurement: Imag = 6.2114 +- 0.0000 A 10:26:15 Magnet current ramping to 8.0000 A... 10:26:31 Magnet Current, Imag = 8.2420 A Vtrans = 0.082420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:26:33 Magnet Current, Imag = 8.2417 A Vtrans = 0.082417 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:26:35 Magnet Current, Imag = 8.2416 A Vtrans = 0.082416 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:26:37 Magnet Current, Imag = 8.2415 A Vtrans = 0.082415 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:26:37 Magnet Current Measurement: Imag = 8.2417 +- 0.0002 A 10:26:37 Magnetic Field Measurement Measuring the magnet strength... 10:26:37 Integrated Voltage Measurement... 10:26:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000233167 Vs 10:27:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000215320 Vs 10:27:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000234270 Vs 10:27:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000215230 Vs 10:27:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000233149 Vs 10:27:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000215727 Vs 10:27:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000233006 Vs 10:28:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000214645 Vs 10:28:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000224314 +- 0.000000335 Vs 10:28:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000224314 +- 0.000000335 Vs BL = 0.02243143 +- 0.00003350 Tm 10:28:09 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.02243 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.02243 0.00003 0.02243 0.00000 10:28:09 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.02243 0.00003 SL = 0.0224314 +- 0.0000335 Tm^2/m^n 10:28:09 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0224314 +- 0.0000335 Tm^2/m^n 10:28:11 Magnet Current, Imag = 8.2394 A Vtrans = 0.082394 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:28:13 Magnet Current, Imag = 8.2394 A Vtrans = 0.082394 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:28:15 Magnet Current, Imag = 8.2394 A Vtrans = 0.082394 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:28:17 Magnet Current, Imag = 8.2394 A Vtrans = 0.082394 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:28:17 Magnet Current Measurement: Imag = 8.2394 +- 0.0000 A 10:28:17 Magnet current ramping to 10.0000 A... 10:28:33 Magnet Current, Imag = 10.2681 A Vtrans = 0.102681 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:28:35 Magnet Current, Imag = 10.2680 A Vtrans = 0.102680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:28:37 Magnet Current, Imag = 10.2676 A Vtrans = 0.102676 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:28:39 Magnet Current, Imag = 10.2675 A Vtrans = 0.102675 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:28:39 Magnet Current Measurement: Imag = 10.2678 +- 0.0003 A 10:28:39 Magnetic Field Measurement Measuring the magnet strength... 10:28:39 Integrated Voltage Measurement... 10:28:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000285813 Vs 10:29:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000268071 Vs 10:29:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000285880 Vs 10:29:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000267078 Vs 10:29:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000286186 Vs 10:29:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000267174 Vs 10:29:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000286025 Vs 10:30:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000267975 Vs 10:30:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000276775 +- 0.000000209 Vs 10:30:08 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000276775 +- 0.000000209 Vs BL = 0.02767753 +- 0.00002092 Tm 10:30:11 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.02768 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.02768 0.00002 0.02768 0.00000 10:30:11 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.02768 0.00002 SL = 0.0276775 +- 0.0000209 Tm^2/m^n 10:30:11 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0276775 +- 0.0000209 Tm^2/m^n 10:30:13 Magnet Current, Imag = 10.2646 A Vtrans = 0.102647 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:30:15 Magnet Current, Imag = 10.2647 A Vtrans = 0.102647 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:30:17 Magnet Current, Imag = 10.2647 A Vtrans = 0.102647 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:30:19 Magnet Current, Imag = 10.2647 A Vtrans = 0.102647 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:30:19 Magnet Current Measurement: Imag = 10.2647 +- 0.0000 A 10:30:19 Magnet current ramping to 12.0000 A... 10:30:35 Magnet Current, Imag = 12.2928 A Vtrans = 0.122928 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:30:37 Magnet Current, Imag = 12.2926 A Vtrans = 0.122926 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:30:38 Magnet Current, Imag = 12.2923 A Vtrans = 0.122923 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:30:40 Magnet Current, Imag = 12.2921 A Vtrans = 0.122921 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:30:40 Magnet Current Measurement: Imag = 12.2924 +- 0.0003 A 10:30:40 Magnetic Field Measurement Measuring the magnet strength... 10:30:40 Integrated Voltage Measurement... 10:30:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000337229 Vs 10:31:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000320909 Vs 10:31:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000336908 Vs 10:31:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000320530 Vs 10:31:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000336551 Vs 10:31:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000319891 Vs 10:31:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000338190 Vs 10:32:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000319542 Vs 10:32:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000328719 +- 0.000000313 Vs 10:32:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000328719 +- 0.000000313 Vs BL = 0.03287186 +- 0.00003131 Tm 10:32:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.03287 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.03287 0.00003 0.03287 0.00000 10:32:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.03287 0.00003 SL = 0.0328719 +- 0.0000313 Tm^2/m^n 10:32:13 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0328719 +- 0.0000313 Tm^2/m^n 10:32:15 Magnet Current, Imag = 12.2880 A Vtrans = 0.122880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:32:17 Magnet Current, Imag = 12.2880 A Vtrans = 0.122880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:32:18 Magnet Current, Imag = 12.2879 A Vtrans = 0.122879 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:32:20 Magnet Current, Imag = 12.2879 A Vtrans = 0.122879 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:32:20 Magnet Current Measurement: Imag = 12.2879 +- 0.0000 A 10:32:50 Magnet current ramping to 0.0000 A...