SLAC Magnetic Measurements Date: 04-05-2002 Time: 15:08:50 Project: spear3 Magnet Type: gdipole Magnet Name: 109D-032 Serial Number: Run Number: 11 Measurement Device: stretched wire Operator: sa Comment: bl vs. i, trim Test Currents (A): -12.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 15:09:18 Initial Zero Current Measurement, Imag_zero = 0.0000 A 15:09:48 Magnet current ramping to -12.0000 A... 15:10:39 Magnet Current, Imag = -12.0821 A Vtrans = -0.120821 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:10:41 Magnet Current, Imag = -12.0819 A Vtrans = -0.120819 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:10:43 Magnet Current, Imag = -12.0816 A Vtrans = -0.120816 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:10:45 Magnet Current, Imag = -12.0812 A Vtrans = -0.120812 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:10:45 Magnet Current Measurement: Imag = -12.0817 +- 0.0004 A 15:10:45 Magnetic Field Measurement Measuring the magnet strength... 15:10:45 Integrated Voltage Measurement... 15:10:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000433880 Vs 15:11:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000142947 Vs 15:11:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000435129 Vs 15:11:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000143051 Vs 15:11:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000434719 Vs 15:11:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000142801 Vs 15:12:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000435679 Vs 15:12:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000141993 Vs 15:12:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000288775 +- 0.000000242 Vs 15:12:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000288775 +- 0.000000242 Vs BL = -0.02887747 +- 0.00002418 Tm 15:12:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02888 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.02888 0.00002 -0.02888 0.00000 15:12:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02888 0.00002 SL = -0.0288775 +- 0.0000242 Tm^2/m^n 15:12:15 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0288775 +- 0.0000242 Tm^2/m^n 15:12:17 Magnet Current, Imag = -12.0721 A Vtrans = -0.120721 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:12:19 Magnet Current, Imag = -12.0720 A Vtrans = -0.120720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:12:21 Magnet Current, Imag = -12.0718 A Vtrans = -0.120718 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:12:23 Magnet Current, Imag = -12.0717 A Vtrans = -0.120717 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:12:23 Magnet Current Measurement: Imag = -12.0719 +- 0.0001 A 15:12:23 Magnet current ramping to -10.0000 A... 15:12:39 Magnet Current, Imag = -10.0376 A Vtrans = -0.100376 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:12:41 Magnet Current, Imag = -10.0377 A Vtrans = -0.100377 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:12:43 Magnet Current, Imag = -10.0376 A Vtrans = -0.100376 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:12:45 Magnet Current, Imag = -10.0377 A Vtrans = -0.100377 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:12:45 Magnet Current Measurement: Imag = -10.0376 +- 0.0000 A 15:12:45 Magnetic Field Measurement Measuring the magnet strength... 15:12:45 Integrated Voltage Measurement... 15:12:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000383745 Vs 15:13:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000092255 Vs 15:13:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000383401 Vs 15:13:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000092306 Vs 15:13:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000383232 Vs 15:13:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000091958 Vs 15:14:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000384183 Vs 15:14:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000092968 Vs 15:14:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000238006 +- 0.000000359 Vs 15:14:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000238006 +- 0.000000359 Vs BL = -0.02380061 +- 0.00003594 Tm 15:14:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02380 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.02380 0.00004 -0.02380 0.00000 15:14:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02380 0.00004 SL = -0.0238006 +- 0.0000359 Tm^2/m^n 15:14:15 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0238006 +- 0.0000359 Tm^2/m^n 15:14:17 Magnet Current, Imag = -10.0375 A Vtrans = -0.100375 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:14:19 Magnet Current, Imag = -10.0375 A Vtrans = -0.100375 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:14:21 Magnet Current, Imag = -10.0375 A Vtrans = -0.100375 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:14:23 Magnet Current, Imag = -10.0375 A Vtrans = -0.100375 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:14:23 Magnet Current Measurement: Imag = -10.0375 +- 0.0000 A 15:14:23 Magnet current ramping to -8.0000 A... 15:14:39 Magnet Current, Imag = -8.0083 A Vtrans = -0.080083 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:14:41 Magnet Current, Imag = -8.0083 A Vtrans = -0.080083 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:14:42 Magnet Current, Imag = -8.0084 A Vtrans = -0.080084 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:14:44 Magnet Current, Imag = -8.0084 A Vtrans = -0.080085 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:14:44 Magnet Current Measurement: Imag = -8.0084 +- 0.0001 A 15:14:44 Magnetic Field Measurement Measuring the magnet strength... 15:14:44 Integrated Voltage Measurement... 15:14:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000331396 Vs 15:15:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000042132 Vs 15:15:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000333244 Vs 15:15:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000041764 Vs 15:15:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000333482 Vs 15:15:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000040831 Vs 15:16:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000332623 Vs 15:16:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000040750 Vs 15:16:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000187028 +- 0.000000328 Vs 15:16:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000187028 +- 0.000000328 Vs BL = -0.01870278 +- 0.00003276 Tm 15:16:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01870 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.01870 0.00003 -0.01870 0.00000 15:16:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01870 0.00003 SL = -0.0187028 +- 0.0000328 Tm^2/m^n 15:16:15 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0187028 +- 0.0000328 Tm^2/m^n 15:16:16 Magnet Current, Imag = -8.0095 A Vtrans = -0.080095 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:16:18 Magnet Current, Imag = -8.0094 A Vtrans = -0.080094 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:16:20 Magnet Current, Imag = -8.0094 A Vtrans = -0.080094 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:16:22 Magnet Current, Imag = -8.0095 A Vtrans = -0.080095 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:16:22 Magnet Current Measurement: Imag = -8.0095 +- 0.0000 A 15:16:22 Magnet current ramping to -6.0000 A... 15:16:38 Magnet Current, Imag = -5.9787 A Vtrans = -0.059787 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:16:40 Magnet Current, Imag = -5.9788 A Vtrans = -0.059788 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:16:42 Magnet Current, Imag = -5.9788 A Vtrans = -0.059788 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:16:44 Magnet Current, Imag = -5.9789 A Vtrans = -0.059789 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:16:44 Magnet Current Measurement: Imag = -5.9788 +- 0.0001 A 15:16:44 Magnetic Field Measurement Measuring the magnet strength... 15:16:44 Integrated Voltage Measurement... 15:16:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000279949 Vs 15:17:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000010009 Vs 15:17:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000281177 Vs 15:17:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000008348 Vs 15:17:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000279891 Vs 15:17:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000008597 Vs 15:18:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000279268 Vs 15:18:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000006910 Vs 15:18:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000135803 +- 0.000000555 Vs 15:18:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000135803 +- 0.000000555 Vs BL = -0.01358025 +- 0.00005554 Tm 15:18:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01358 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.01358 0.00006 -0.01358 0.00000 15:18:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01358 0.00006 SL = -0.0135803 +- 0.0000555 Tm^2/m^n 15:18:14 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0135803 +- 0.0000555 Tm^2/m^n 15:18:16 Magnet Current, Imag = -5.9798 A Vtrans = -0.059798 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:18:18 Magnet Current, Imag = -5.9798 A Vtrans = -0.059799 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:18:20 Magnet Current, Imag = -5.9798 A Vtrans = -0.059798 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:18:22 Magnet Current, Imag = -5.9798 A Vtrans = -0.059798 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:18:22 Magnet Current Measurement: Imag = -5.9798 +- 0.0000 A 15:18:22 Magnet current ramping to -4.0000 A... 15:18:38 Magnet Current, Imag = -3.9490 A Vtrans = -0.039490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:18:40 Magnet Current, Imag = -3.9491 A Vtrans = -0.039491 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:18:42 Magnet Current, Imag = -3.9491 A Vtrans = -0.039491 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:18:44 Magnet Current, Imag = -3.9491 A Vtrans = -0.039491 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:18:44 Magnet Current Measurement: Imag = -3.9491 +- 0.0001 A 15:18:44 Magnetic Field Measurement Measuring the magnet strength... 15:18:44 Integrated Voltage Measurement... 15:18:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000226973 Vs 15:19:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000058242 Vs 15:19:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000227913 Vs 15:19:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000058881 Vs 15:19:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000227812 Vs 15:19:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000060699 Vs 15:20:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000228231 Vs 15:20:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000058753 Vs 15:20:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000084294 +- 0.000000446 Vs 15:20:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000084294 +- 0.000000446 Vs BL = -0.00842944 +- 0.00004462 Tm 15:20:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00843 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00843 0.00004 -0.00843 0.00000 15:20:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00843 0.00004 SL = -0.0084294 +- 0.0000446 Tm^2/m^n 15:20:14 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0084294 +- 0.0000446 Tm^2/m^n 15:20:16 Magnet Current, Imag = -3.9498 A Vtrans = -0.039498 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:20:18 Magnet Current, Imag = -3.9499 A Vtrans = -0.039499 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:20:20 Magnet Current, Imag = -3.9498 A Vtrans = -0.039498 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:20:22 Magnet Current, Imag = -3.9498 A Vtrans = -0.039498 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:20:22 Magnet Current Measurement: Imag = -3.9498 +- 0.0000 A 15:20:22 Magnet current ramping to -2.0000 A... 15:20:38 Magnet Current, Imag = -1.9191 A Vtrans = -0.019191 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:20:40 Magnet Current, Imag = -1.9191 A Vtrans = -0.019191 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:20:42 Magnet Current, Imag = -1.9191 A Vtrans = -0.019191 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:20:44 Magnet Current, Imag = -1.9191 A Vtrans = -0.019191 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:20:44 Magnet Current Measurement: Imag = -1.9191 +- 0.0000 A 15:20:44 Magnetic Field Measurement Measuring the magnet strength... 15:20:44 Integrated Voltage Measurement... 15:20:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000174678 Vs 15:21:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000110355 Vs 15:21:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000174993 Vs 15:21:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000110833 Vs 15:21:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000176507 Vs 15:21:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000110597 Vs 15:22:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000176092 Vs 15:22:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000108821 Vs 15:22:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000032708 +- 0.000000635 Vs 15:22:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000032708 +- 0.000000635 Vs BL = -0.00327080 +- 0.00006353 Tm 15:22:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00327 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00327 0.00006 -0.00327 0.00000 15:22:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00327 0.00006 SL = -0.0032708 +- 0.0000635 Tm^2/m^n 15:22:14 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0032708 +- 0.0000635 Tm^2/m^n 15:22:16 Magnet Current, Imag = -1.9194 A Vtrans = -0.019194 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:22:18 Magnet Current, Imag = -1.9194 A Vtrans = -0.019194 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:22:20 Magnet Current, Imag = -1.9194 A Vtrans = -0.019194 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:22:22 Magnet Current, Imag = -1.9195 A Vtrans = -0.019195 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:22:22 Magnet Current Measurement: Imag = -1.9194 +- 0.0000 A 15:22:22 Magnet current ramping to 0.0000 A... 15:22:38 Magnet Current, Imag = 0.1130 A Vtrans = 0.001130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:22:40 Magnet Current, Imag = 0.1129 A Vtrans = 0.001129 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:22:41 Magnet Current, Imag = 0.1129 A Vtrans = 0.001129 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:22:43 Magnet Current, Imag = 0.1130 A Vtrans = 0.001130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:22:43 Magnet Current Measurement: Imag = 0.1130 +- 0.0001 A 15:22:43 Magnetic Field Measurement Measuring the magnet strength... 15:22:43 Integrated Voltage Measurement... 15:22:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000123539 Vs 15:23:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000161036 Vs 15:23:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000122860 Vs 15:23:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000161489 Vs 15:23:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000122178 Vs 15:23:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000161204 Vs 15:24:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000123489 Vs 15:24:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000162849 Vs 15:24:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000019314 +- 0.000000351 Vs 15:24:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000019314 +- 0.000000351 Vs BL = 0.00193141 +- 0.00003513 Tm 15:24:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00193 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00193 0.00004 0.00193 0.00000 15:24:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00193 0.00004 SL = 0.0019314 +- 0.0000351 Tm^2/m^n 15:24:14 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0019314 +- 0.0000351 Tm^2/m^n 15:24:16 Magnet Current, Imag = 0.1128 A Vtrans = 0.001128 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:24:18 Magnet Current, Imag = 0.1128 A Vtrans = 0.001128 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:24:19 Magnet Current, Imag = 0.1128 A Vtrans = 0.001128 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:24:21 Magnet Current, Imag = 0.1127 A Vtrans = 0.001127 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:24:21 Magnet Current Measurement: Imag = 0.1128 +- 0.0000 A 15:24:22 Magnet current ramping to 2.0000 A... 15:24:37 Magnet Current, Imag = 2.1449 A Vtrans = 0.021449 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:24:39 Magnet Current, Imag = 2.1449 A Vtrans = 0.021449 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:24:41 Magnet Current, Imag = 2.1448 A Vtrans = 0.021448 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:24:43 Magnet Current, Imag = 2.1448 A Vtrans = 0.021448 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:24:43 Magnet Current Measurement: Imag = 2.1449 +- 0.0000 A 15:24:43 Magnetic Field Measurement Measuring the magnet strength... 15:24:43 Integrated Voltage Measurement... 15:24:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000071872 Vs 15:25:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000214652 Vs 15:25:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000072959 Vs 15:25:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000214787 Vs 15:25:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000072472 Vs 15:25:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000214673 Vs 15:26:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000072823 Vs 15:26:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000214537 Vs 15:26:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000071065 +- 0.000000208 Vs 15:26:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000071065 +- 0.000000208 Vs BL = 0.00710653 +- 0.00002080 Tm 15:26:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00711 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00711 0.00002 0.00711 0.00000 15:26:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00711 0.00002 SL = 0.0071065 +- 0.0000208 Tm^2/m^n 15:26:14 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0071065 +- 0.0000208 Tm^2/m^n 15:26:15 Magnet Current, Imag = 2.1447 A Vtrans = 0.021447 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:26:17 Magnet Current, Imag = 2.1446 A Vtrans = 0.021446 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:26:19 Magnet Current, Imag = 2.1446 A Vtrans = 0.021446 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:26:21 Magnet Current, Imag = 2.1446 A Vtrans = 0.021446 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:26:21 Magnet Current Measurement: Imag = 2.1446 +- 0.0000 A 15:26:21 Magnet current ramping to 4.0000 A... 15:26:37 Magnet Current, Imag = 4.1762 A Vtrans = 0.041762 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:26:39 Magnet Current, Imag = 4.1762 A Vtrans = 0.041762 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:26:41 Magnet Current, Imag = 4.1761 A Vtrans = 0.041761 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:26:43 Magnet Current, Imag = 4.1760 A Vtrans = 0.041760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:26:43 Magnet Current Measurement: Imag = 4.1761 +- 0.0001 A 15:26:43 Magnetic Field Measurement Measuring the magnet strength... 15:26:43 Integrated Voltage Measurement... 15:26:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000021577 Vs 15:27:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000267725 Vs 15:27:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000020961 Vs 15:27:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000267329 Vs 15:27:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000021164 Vs 15:27:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000266845 Vs 15:28:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000021339 Vs 15:28:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000266113 Vs 15:28:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000122871 +- 0.000000306 Vs 15:28:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000122871 +- 0.000000306 Vs BL = 0.01228714 +- 0.00003062 Tm 15:28:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.01229 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.01229 0.00003 0.01229 0.00000 15:28:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.01229 0.00003 SL = 0.0122871 +- 0.0000306 Tm^2/m^n 15:28:13 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0122871 +- 0.0000306 Tm^2/m^n 15:28:15 Magnet Current, Imag = 4.1756 A Vtrans = 0.041756 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:17 Magnet Current, Imag = 4.1755 A Vtrans = 0.041755 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:19 Magnet Current, Imag = 4.1755 A Vtrans = 0.041755 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:21 Magnet Current, Imag = 4.1755 A Vtrans = 0.041755 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:21 Magnet Current Measurement: Imag = 4.1755 +- 0.0000 A 15:28:21 Magnet current ramping to 6.0000 A... 15:28:37 Magnet Current, Imag = 6.2068 A Vtrans = 0.062068 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:39 Magnet Current, Imag = 6.2067 A Vtrans = 0.062067 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:41 Magnet Current, Imag = 6.2066 A Vtrans = 0.062066 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:43 Magnet Current, Imag = 6.2065 A Vtrans = 0.062065 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:43 Magnet Current Measurement: Imag = 6.2067 +- 0.0001 A 15:28:43 Magnetic Field Measurement Measuring the magnet strength... 15:28:43 Integrated Voltage Measurement... 15:28:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000031111 Vs 15:29:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000320169 Vs 15:29:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000029829 Vs 15:29:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000319629 Vs 15:29:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000029919 Vs 15:29:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000319978 Vs 15:29:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000029951 Vs 15:30:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000319279 Vs 15:30:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000174983 +- 0.000000398 Vs 15:30:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000174983 +- 0.000000398 Vs BL = 0.01749832 +- 0.00003977 Tm 15:30:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.01750 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.01750 0.00004 0.01750 0.00000 15:30:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.01750 0.00004 SL = 0.0174983 +- 0.0000398 Tm^2/m^n 15:30:13 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0174983 +- 0.0000398 Tm^2/m^n 15:30:15 Magnet Current, Imag = 6.2053 A Vtrans = 0.062053 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:17 Magnet Current, Imag = 6.2052 A Vtrans = 0.062052 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:19 Magnet Current, Imag = 6.2052 A Vtrans = 0.062052 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:21 Magnet Current, Imag = 6.2052 A Vtrans = 0.062052 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:21 Magnet Current Measurement: Imag = 6.2052 +- 0.0000 A 15:30:21 Magnet current ramping to 8.0000 A... 15:30:37 Magnet Current, Imag = 8.2360 A Vtrans = 0.082360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:39 Magnet Current, Imag = 8.2356 A Vtrans = 0.082356 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:41 Magnet Current, Imag = 8.2355 A Vtrans = 0.082355 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:43 Magnet Current, Imag = 8.2353 A Vtrans = 0.082353 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:43 Magnet Current Measurement: Imag = 8.2356 +- 0.0002 A 15:30:43 Magnetic Field Measurement Measuring the magnet strength... 15:30:43 Integrated Voltage Measurement... 15:30:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000082155 Vs 15:31:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000371445 Vs 15:31:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000081751 Vs 15:31:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000372381 Vs 15:31:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000082838 Vs 15:31:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000371211 Vs 15:31:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000082743 Vs 15:32:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000371483 Vs 15:32:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000227001 +- 0.000000120 Vs 15:32:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000227001 +- 0.000000120 Vs BL = 0.02270007 +- 0.00001202 Tm 15:32:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.02270 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.02270 0.00001 0.02270 0.00000 15:32:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.02270 0.00001 SL = 0.0227001 +- 0.0000120 Tm^2/m^n 15:32:13 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0227001 +- 0.0000120 Tm^2/m^n 15:32:15 Magnet Current, Imag = 8.2333 A Vtrans = 0.082333 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:17 Magnet Current, Imag = 8.2333 A Vtrans = 0.082333 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:19 Magnet Current, Imag = 8.2333 A Vtrans = 0.082333 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:20 Magnet Current, Imag = 8.2333 A Vtrans = 0.082333 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:21 Magnet Current Measurement: Imag = 8.2333 +- 0.0000 A 15:32:21 Magnet current ramping to 10.0000 A... 15:32:37 Magnet Current, Imag = 10.2624 A Vtrans = 0.102624 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:38 Magnet Current, Imag = 10.2622 A Vtrans = 0.102622 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:40 Magnet Current, Imag = 10.2620 A Vtrans = 0.102620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:42 Magnet Current, Imag = 10.2617 A Vtrans = 0.102617 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:42 Magnet Current Measurement: Imag = 10.2621 +- 0.0003 A 15:32:42 Magnetic Field Measurement Measuring the magnet strength... 15:32:42 Integrated Voltage Measurement... 15:32:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000133781 Vs 15:33:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000423575 Vs 15:33:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000134525 Vs 15:33:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000423969 Vs 15:33:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000134527 Vs 15:33:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000423072 Vs 15:33:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000134379 Vs 15:34:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000423837 Vs 15:34:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000278958 +- 0.000000229 Vs 15:34:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000278958 +- 0.000000229 Vs BL = 0.02789583 +- 0.00002289 Tm 15:34:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.02790 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.02790 0.00002 0.02790 0.00000 15:34:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.02790 0.00002 SL = 0.0278958 +- 0.0000229 Tm^2/m^n 15:34:13 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0278958 +- 0.0000229 Tm^2/m^n 15:34:14 Magnet Current, Imag = 10.2586 A Vtrans = 0.102586 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:16 Magnet Current, Imag = 10.2586 A Vtrans = 0.102586 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:18 Magnet Current, Imag = 10.2587 A Vtrans = 0.102587 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:20 Magnet Current, Imag = 10.2586 A Vtrans = 0.102586 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:20 Magnet Current Measurement: Imag = 10.2586 +- 0.0000 A 15:34:20 Magnet current ramping to 12.0000 A... 15:34:36 Magnet Current, Imag = 12.2867 A Vtrans = 0.122867 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:38 Magnet Current, Imag = 12.2865 A Vtrans = 0.122865 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:40 Magnet Current, Imag = 12.2862 A Vtrans = 0.122862 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:42 Magnet Current, Imag = 12.2859 A Vtrans = 0.122859 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:42 Magnet Current Measurement: Imag = 12.2863 +- 0.0003 A 15:34:42 Magnetic Field Measurement Measuring the magnet strength... 15:34:42 Integrated Voltage Measurement... 15:34:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000185629 Vs 15:35:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000475688 Vs 15:35:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000184773 Vs 15:35:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000476471 Vs 15:35:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000185026 Vs 15:35:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000476832 Vs 15:35:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000185027 Vs 15:36:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000476708 Vs 15:36:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000330769 +- 0.000000131 Vs 15:36:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000330769 +- 0.000000131 Vs BL = 0.03307693 +- 0.00001314 Tm 15:36:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.03308 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.03308 0.00001 0.03308 0.00000 15:36:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.03308 0.00001 SL = 0.0330769 +- 0.0000131 Tm^2/m^n 15:36:12 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0330769 +- 0.0000131 Tm^2/m^n 15:36:14 Magnet Current, Imag = 12.2817 A Vtrans = 0.122817 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:16 Magnet Current, Imag = 12.2817 A Vtrans = 0.122817 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:18 Magnet Current, Imag = 12.2817 A Vtrans = 0.122817 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:20 Magnet Current, Imag = 12.2817 A Vtrans = 0.122817 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:20 Magnet Current Measurement: Imag = 12.2817 +- 0.0000 A 15:36:50 Magnet current ramping to 0.0000 A...