SLAC Magnetic Measurements Date: 04-05-2002 Time: 13:58:55 Project: spear3 Magnet Type: gdipole Magnet Name: 109D-032 Serial Number: Run Number: 10 Measurement Device: stretched wire Operator: sa Comment: bl vs. i, mains Standardization: 1 cycles from 0.0 A to 770.0 A to 0.0 A Test Currents (A): 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 500.0 525.0 550.0 575.0 600.0 625.0 650.0 675.0 700.0 650.0 600.0 550.0 500.0 450.0 400.0 13:59:28 Initial Zero Current Measurement, Imag_zero = 0.0000 A 13:59:28 Magnet current ramping to 15.0000 A... 13:59:59 Magnet current ramping to 770.0000 A... 14:04:15 Magnet current ramping to 0.0000 A... 14:09:04 Magnet current ramping to 50.0000 A... 14:09:27 Magnet Current, Imag = 60.8277 A Vtrans = 0.608277 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:09:29 Magnet Current, Imag = 47.6481 A Vtrans = 0.476481 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:09:30 Magnet Current, Imag = 47.4848 A Vtrans = 0.474848 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:09:32 Magnet Current, Imag = 50.3381 A Vtrans = 0.503381 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:09:32 Magnet Current Measurement: Imag = 51.5747 +- 5.4611 A 14:09:32 Magnetic Field Measurement Measuring the magnet strength... 14:09:32 Integrated Voltage Measurement... 14:09:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001062629 Vs 14:09:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001377445 Vs 14:10:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001058271 Vs 14:10:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001379061 Vs 14:10:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001047635 Vs 14:10:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001378958 Vs 14:10:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001041476 Vs 14:10:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001376996 Vs 14:10:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001215309 +- 0.000004317 Vs 14:10:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001215309 +- 0.000004317 Vs BL = 0.12153087 +- 0.00043172 Tm 14:11:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.12153 0.00043 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.12153 0.00043 0.12153 0.00000 14:11:02 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.12153 0.00043 SL = 0.1215309 +- 0.0004317 Tm^2/m^n 14:11:02 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1215309 +- 0.0004317 Tm^2/m^n 14:11:04 Magnet Current, Imag = 49.6208 A Vtrans = 0.496208 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:05 Magnet Current, Imag = 49.6157 A Vtrans = 0.496157 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:07 Magnet Current, Imag = 49.6209 A Vtrans = 0.496209 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:08 Magnet Current, Imag = 49.6392 A Vtrans = 0.496392 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:08 Magnet Current Measurement: Imag = 49.6242 +- 0.0089 A 14:11:08 Magnet current ramping to 100.0000 A... 14:11:31 Magnet Current, Imag = 99.6899 A Vtrans = 0.996899 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:32 Magnet Current, Imag = 99.7104 A Vtrans = 0.997104 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:34 Magnet Current, Imag = 99.6725 A Vtrans = 0.996725 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:35 Magnet Current, Imag = 99.6889 A Vtrans = 0.996889 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:35 Magnet Current Measurement: Imag = 99.6904 +- 0.0134 A 14:11:35 Magnetic Field Measurement Measuring the magnet strength... 14:11:35 Integrated Voltage Measurement... 14:11:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002244558 Vs 14:11:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002578287 Vs 14:12:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002242661 Vs 14:12:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002581088 Vs 14:12:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002239447 Vs 14:12:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002579815 Vs 14:12:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002252785 Vs 14:13:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002581571 Vs 14:13:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002412526 +- 0.000002814 Vs 14:13:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.002412526 +- 0.000002814 Vs BL = 0.24125265 +- 0.00028138 Tm 14:13:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.24125 0.00028 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.24125 0.00028 0.24125 0.00000 14:13:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.24125 0.00028 SL = 0.2412526 +- 0.0002814 Tm^2/m^n 14:13:06 Magnet Strength Measurement Harmonic Number = 1 SL = 0.2412526 +- 0.0002814 Tm^2/m^n 14:13:07 Magnet Current, Imag = 99.6719 A Vtrans = 0.996719 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:08 Magnet Current, Imag = 99.6796 A Vtrans = 0.996796 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:10 Magnet Current, Imag = 99.6824 A Vtrans = 0.996824 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:11 Magnet Current, Imag = 99.6819 A Vtrans = 0.996819 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:11 Magnet Current Measurement: Imag = 99.6790 +- 0.0042 A 14:13:11 Magnet current ramping to 150.0000 A... 14:13:34 Magnet Current, Imag = 149.7256 A Vtrans = 1.497256 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:36 Magnet Current, Imag = 149.7088 A Vtrans = 1.497088 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:37 Magnet Current, Imag = 149.7246 A Vtrans = 1.497246 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:39 Magnet Current, Imag = 149.7363 A Vtrans = 1.497363 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:39 Magnet Current Measurement: Imag = 149.7238 +- 0.0098 A 14:13:39 Magnetic Field Measurement Measuring the magnet strength... 14:13:39 Integrated Voltage Measurement... 14:13:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003451303 Vs 14:14:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003787660 Vs 14:14:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003456247 Vs 14:14:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003792141 Vs 14:14:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003458685 Vs 14:14:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003788168 Vs 14:14:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003451669 Vs 14:15:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003786111 Vs 14:15:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003621498 +- 0.000002338 Vs 14:15:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.003621498 +- 0.000002338 Vs BL = 0.36214979 +- 0.00023375 Tm 14:15:09 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.36215 0.00023 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.36215 0.00023 0.36215 0.00000 14:15:09 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.36215 0.00023 SL = 0.3621498 +- 0.0002338 Tm^2/m^n 14:15:09 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3621498 +- 0.0002338 Tm^2/m^n 14:15:10 Magnet Current, Imag = 149.7127 A Vtrans = 1.497127 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:12 Magnet Current, Imag = 149.7396 A Vtrans = 1.497396 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:13 Magnet Current, Imag = 149.7409 A Vtrans = 1.497409 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:15 Magnet Current, Imag = 149.7223 A Vtrans = 1.497223 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:15 Magnet Current Measurement: Imag = 149.7289 +- 0.0119 A 14:15:15 Magnet current ramping to 200.0000 A... 14:15:40 Magnet Current, Imag = 199.7473 A Vtrans = 1.997473 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:41 Magnet Current, Imag = 199.7506 A Vtrans = 1.997506 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:43 Magnet Current, Imag = 199.7626 A Vtrans = 1.997626 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:44 Magnet Current, Imag = 199.7487 A Vtrans = 1.997487 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:44 Magnet Current Measurement: Imag = 199.7523 +- 0.0061 A 14:15:44 Magnetic Field Measurement Measuring the magnet strength... 14:15:44 Integrated Voltage Measurement... 14:15:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004668801 Vs 14:16:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005009265 Vs 14:16:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004668664 Vs 14:16:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004993772 Vs 14:16:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004665442 Vs 14:16:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005002439 Vs 14:17:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004674228 Vs 14:17:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004994156 Vs 14:17:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004834596 +- 0.000002815 Vs 14:17:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004834596 +- 0.000002815 Vs BL = 0.48345958 +- 0.00028147 Tm 14:17:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.48346 0.00028 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.48346 0.00028 0.48346 0.00000 14:17:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.48346 0.00028 SL = 0.4834596 +- 0.0002815 Tm^2/m^n 14:17:14 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4834596 +- 0.0002815 Tm^2/m^n 14:17:16 Magnet Current, Imag = 199.7478 A Vtrans = 1.997478 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:17 Magnet Current, Imag = 199.7590 A Vtrans = 1.997590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:19 Magnet Current, Imag = 199.7557 A Vtrans = 1.997557 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:20 Magnet Current, Imag = 199.7450 A Vtrans = 1.997450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:20 Magnet Current Measurement: Imag = 199.7519 +- 0.0057 A 14:17:20 Magnet current ramping to 250.0000 A... 14:17:43 Magnet Current, Imag = 249.8123 A Vtrans = 2.498123 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:44 Magnet Current, Imag = 249.8106 A Vtrans = 2.498106 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:46 Magnet Current, Imag = 249.8085 A Vtrans = 2.498085 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:47 Magnet Current, Imag = 249.7953 A Vtrans = 2.497953 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:47 Magnet Current Measurement: Imag = 249.8067 +- 0.0067 A 14:17:47 Magnetic Field Measurement Measuring the magnet strength... 14:17:47 Integrated Voltage Measurement... 14:18:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005876233 Vs 14:18:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006220445 Vs 14:18:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005878001 Vs 14:18:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006209764 Vs 14:18:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005887035 Vs 14:18:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006217519 Vs 14:19:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005890701 Vs 14:19:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006213982 Vs 14:19:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006049210 +- 0.000003477 Vs 14:19:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006049210 +- 0.000003477 Vs BL = 0.60492101 +- 0.00034769 Tm 14:19:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.60492 0.00035 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.60492 0.00035 0.60492 0.00000 14:19:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.60492 0.00035 SL = 0.6049210 +- 0.0003477 Tm^2/m^n 14:19:18 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6049210 +- 0.0003477 Tm^2/m^n 14:19:19 Magnet Current, Imag = 249.8024 A Vtrans = 2.498024 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:21 Magnet Current, Imag = 249.7901 A Vtrans = 2.497901 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:22 Magnet Current, Imag = 249.8017 A Vtrans = 2.498017 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:24 Magnet Current, Imag = 249.8188 A Vtrans = 2.498188 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:24 Magnet Current Measurement: Imag = 249.8032 +- 0.0102 A 14:19:24 Magnet current ramping to 300.0000 A... 14:19:46 Magnet Current, Imag = 299.8375 A Vtrans = 2.998375 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:48 Magnet Current, Imag = 299.8504 A Vtrans = 2.998504 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:49 Magnet Current, Imag = 299.8781 A Vtrans = 2.998781 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:51 Magnet Current, Imag = 299.8597 A Vtrans = 2.998597 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:51 Magnet Current Measurement: Imag = 299.8564 +- 0.0148 A 14:19:51 Magnetic Field Measurement Measuring the magnet strength... 14:19:51 Integrated Voltage Measurement... 14:20:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007092615 Vs 14:20:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007415670 Vs 14:20:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007097832 Vs 14:20:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007428995 Vs 14:20:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007106617 Vs 14:20:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007418969 Vs 14:21:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007093315 Vs 14:21:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007420902 Vs 14:21:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007259364 +- 0.000003890 Vs 14:21:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.007259364 +- 0.000003890 Vs BL = 0.72593644 +- 0.00038895 Tm 14:21:21 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.72594 0.00039 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.72594 0.00039 0.72594 0.00000 14:21:21 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.72594 0.00039 SL = 0.7259364 +- 0.0003890 Tm^2/m^n 14:21:21 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7259364 +- 0.0003890 Tm^2/m^n 14:21:23 Magnet Current, Imag = 299.8407 A Vtrans = 2.998407 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:24 Magnet Current, Imag = 299.8489 A Vtrans = 2.998489 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:25 Magnet Current, Imag = 299.8651 A Vtrans = 2.998651 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:27 Magnet Current, Imag = 299.8734 A Vtrans = 2.998734 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:27 Magnet Current Measurement: Imag = 299.8570 +- 0.0129 A 14:21:27 Magnet current ramping to 350.0000 A... 14:21:50 Magnet Current, Imag = 349.9220 A Vtrans = 3.499220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:52 Magnet Current, Imag = 349.9260 A Vtrans = 3.499260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:54 Magnet Current, Imag = 349.9220 A Vtrans = 3.499220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:56 Magnet Current, Imag = 349.9050 A Vtrans = 3.499050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:56 Magnet Current Measurement: Imag = 349.9187 +- 0.0081 A 14:21:56 Magnetic Field Measurement Measuring the magnet strength... 14:21:56 Integrated Voltage Measurement... 14:22:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008306975 Vs 14:22:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008641708 Vs 14:22:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008315821 Vs 14:22:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008637845 Vs 14:22:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008310208 Vs 14:23:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008634775 Vs 14:23:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008308346 Vs 14:23:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008633251 Vs 14:23:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008473616 +- 0.000002240 Vs 14:23:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.008473616 +- 0.000002240 Vs BL = 0.84736163 +- 0.00022404 Tm 14:23:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.84736 0.00022 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.84736 0.00022 0.84736 0.00000 14:23:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.84736 0.00022 SL = 0.8473616 +- 0.0002240 Tm^2/m^n 14:23:26 Magnet Strength Measurement Harmonic Number = 1 SL = 0.8473616 +- 0.0002240 Tm^2/m^n 14:23:28 Magnet Current, Imag = 349.9340 A Vtrans = 3.499340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:23:30 Magnet Current, Imag = 349.9280 A Vtrans = 3.499280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:23:32 Magnet Current, Imag = 349.9100 A Vtrans = 3.499100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:23:34 Magnet Current, Imag = 349.9230 A Vtrans = 3.499230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:23:34 Magnet Current Measurement: Imag = 349.9237 +- 0.0088 A 14:23:34 Magnet current ramping to 400.0000 A... 14:23:58 Magnet Current, Imag = 399.9590 A Vtrans = 3.999590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:23:59 Magnet Current, Imag = 399.9740 A Vtrans = 3.999740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:24:01 Magnet Current, Imag = 399.9560 A Vtrans = 3.999560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:24:02 Magnet Current, Imag = 399.9450 A Vtrans = 3.999450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:24:02 Magnet Current Measurement: Imag = 399.9585 +- 0.0104 A 14:24:02 Magnetic Field Measurement Measuring the magnet strength... 14:24:02 Integrated Voltage Measurement... 14:24:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009525391 Vs 14:24:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009839898 Vs 14:24:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009513232 Vs 14:24:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009843015 Vs 14:24:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009515177 Vs 14:25:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009848780 Vs 14:25:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009517179 Vs 14:25:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009846479 Vs 14:25:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009681144 +- 0.000001771 Vs 14:25:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009681144 +- 0.000001771 Vs BL = 0.96811438 +- 0.00017707 Tm 14:25:33 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.96811 0.00018 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.96811 0.00018 0.96811 0.00000 14:25:33 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.96811 0.00018 SL = 0.9681144 +- 0.0001771 Tm^2/m^n 14:25:33 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9681144 +- 0.0001771 Tm^2/m^n 14:25:34 Magnet Current, Imag = 399.9350 A Vtrans = 3.999350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:25:36 Magnet Current, Imag = 399.9320 A Vtrans = 3.999320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:25:37 Magnet Current, Imag = 399.9420 A Vtrans = 3.999420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:25:39 Magnet Current, Imag = 399.9170 A Vtrans = 3.999170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:25:39 Magnet Current Measurement: Imag = 399.9315 +- 0.0091 A 14:25:39 Magnet current ramping to 450.0000 A... 14:26:02 Magnet Current, Imag = 450.0050 A Vtrans = 4.500050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:26:03 Magnet Current, Imag = 450.0030 A Vtrans = 4.500030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:26:05 Magnet Current, Imag = 449.9980 A Vtrans = 4.499980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:26:07 Magnet Current, Imag = 449.9720 A Vtrans = 4.499720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:26:07 Magnet Current Measurement: Imag = 449.9945 +- 0.0132 A 14:26:07 Magnetic Field Measurement Measuring the magnet strength... 14:26:07 Integrated Voltage Measurement... 14:26:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010718682 Vs 14:26:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011061331 Vs 14:26:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010719783 Vs 14:26:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011055041 Vs 14:27:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010719087 Vs 14:27:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011056449 Vs 14:27:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010717885 Vs 14:27:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011053539 Vs 14:27:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010887725 +- 0.000001529 Vs 14:27:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.010887725 +- 0.000001529 Vs BL = 1.08877248 +- 0.00015293 Tm 14:27:37 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.08877 0.00015 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.08877 0.00015 1.08877 0.00000 14:27:37 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.08877 0.00015 SL = 1.0887725 +- 0.0001529 Tm^2/m^n 14:27:37 Magnet Strength Measurement Harmonic Number = 1 SL = 1.0887725 +- 0.0001529 Tm^2/m^n 14:27:39 Magnet Current, Imag = 450.0020 A Vtrans = 4.500020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:27:40 Magnet Current, Imag = 449.9950 A Vtrans = 4.499950 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:27:42 Magnet Current, Imag = 449.9910 A Vtrans = 4.499910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:27:44 Magnet Current, Imag = 449.9960 A Vtrans = 4.499960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:27:44 Magnet Current Measurement: Imag = 449.9960 +- 0.0039 A 14:27:44 Magnet current ramping to 500.0000 A... 14:28:07 Magnet Current, Imag = 500.0680 A Vtrans = 5.000680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:28:08 Magnet Current, Imag = 500.0680 A Vtrans = 5.000680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:28:10 Magnet Current, Imag = 500.0820 A Vtrans = 5.000820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:28:11 Magnet Current, Imag = 500.0860 A Vtrans = 5.000860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:28:11 Magnet Current Measurement: Imag = 500.0760 +- 0.0081 A 14:28:11 Magnetic Field Measurement Measuring the magnet strength... 14:28:11 Integrated Voltage Measurement... 14:28:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011922335 Vs 14:28:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012257711 Vs 14:28:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011929053 Vs 14:28:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012253373 Vs 14:29:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011933483 Vs 14:29:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012264043 Vs 14:29:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011939750 Vs 14:29:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012250843 Vs 14:29:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012093824 +- 0.000003458 Vs 14:29:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012093824 +- 0.000003458 Vs BL = 1.20938241 +- 0.00034577 Tm 14:29:42 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.20938 0.00035 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.20938 0.00035 1.20938 0.00000 14:29:42 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.20938 0.00035 SL = 1.2093824 +- 0.0003458 Tm^2/m^n 14:29:42 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2093824 +- 0.0003458 Tm^2/m^n 14:29:43 Magnet Current, Imag = 500.0770 A Vtrans = 5.000770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:29:45 Magnet Current, Imag = 500.0700 A Vtrans = 5.000700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:29:46 Magnet Current, Imag = 500.0710 A Vtrans = 5.000710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:29:48 Magnet Current, Imag = 500.0740 A Vtrans = 5.000740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:29:48 Magnet Current Measurement: Imag = 500.0730 +- 0.0027 A 14:29:48 Magnet current ramping to 525.0000 A... 14:30:04 Magnet Current, Imag = 525.0770 A Vtrans = 5.250770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:30:05 Magnet Current, Imag = 525.0750 A Vtrans = 5.250750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:30:07 Magnet Current, Imag = 525.0820 A Vtrans = 5.250820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:30:08 Magnet Current, Imag = 525.0850 A Vtrans = 5.250850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:30:08 Magnet Current Measurement: Imag = 525.0797 +- 0.0040 A 14:30:08 Magnetic Field Measurement Measuring the magnet strength... 14:30:09 Integrated Voltage Measurement... 14:30:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012532540 Vs 14:30:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012840057 Vs 14:30:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012534114 Vs 14:30:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012846145 Vs 14:31:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012531115 Vs 14:31:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012856742 Vs 14:31:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012524625 Vs 14:31:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012856402 Vs 14:31:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012690217 +- 0.000002703 Vs 14:31:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012690217 +- 0.000002703 Vs BL = 1.26902174 +- 0.00027030 Tm 14:31:39 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.26902 0.00027 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.26902 0.00027 1.26902 0.00000 14:31:39 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.26902 0.00027 SL = 1.2690217 +- 0.0002703 Tm^2/m^n 14:31:39 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2690217 +- 0.0002703 Tm^2/m^n 14:31:41 Magnet Current, Imag = 525.0850 A Vtrans = 5.250850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:42 Magnet Current, Imag = 525.0870 A Vtrans = 5.250870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:44 Magnet Current, Imag = 525.0740 A Vtrans = 5.250740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:45 Magnet Current, Imag = 525.0790 A Vtrans = 5.250790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:45 Magnet Current Measurement: Imag = 525.0812 +- 0.0051 A 14:31:45 Magnet current ramping to 550.0000 A... 14:32:01 Magnet Current, Imag = 550.0540 A Vtrans = 5.500540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:32:02 Magnet Current, Imag = 550.0640 A Vtrans = 5.500640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:32:04 Magnet Current, Imag = 550.0670 A Vtrans = 5.500670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:32:06 Magnet Current, Imag = 550.0840 A Vtrans = 5.500840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:32:06 Magnet Current Measurement: Imag = 550.0673 +- 0.0108 A 14:32:06 Magnetic Field Measurement Measuring the magnet strength... 14:32:06 Integrated Voltage Measurement... 14:32:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013114793 Vs 14:32:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013453767 Vs 14:32:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013123438 Vs 14:32:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013448141 Vs 14:33:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013115883 Vs 14:33:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013458100 Vs 14:33:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013114716 Vs 14:33:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013450017 Vs 14:33:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013284857 +- 0.000001729 Vs 14:33:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.013284857 +- 0.000001729 Vs BL = 1.32848568 +- 0.00017293 Tm 14:33:36 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.32849 0.00017 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.32849 0.00017 1.32849 0.00000 14:33:36 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.32849 0.00017 SL = 1.3284857 +- 0.0001729 Tm^2/m^n 14:33:36 Magnet Strength Measurement Harmonic Number = 1 SL = 1.3284857 +- 0.0001729 Tm^2/m^n 14:33:38 Magnet Current, Imag = 550.0800 A Vtrans = 5.500800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:39 Magnet Current, Imag = 550.0910 A Vtrans = 5.500910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:41 Magnet Current, Imag = 550.0750 A Vtrans = 5.500750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:43 Magnet Current, Imag = 550.0640 A Vtrans = 5.500640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:43 Magnet Current Measurement: Imag = 550.0775 +- 0.0097 A 14:33:43 Magnet current ramping to 575.0000 A... 14:33:59 Magnet Current, Imag = 575.0980 A Vtrans = 5.750980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:34:00 Magnet Current, Imag = 575.0980 A Vtrans = 5.750980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:34:02 Magnet Current, Imag = 575.1030 A Vtrans = 5.751030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:34:03 Magnet Current, Imag = 575.1030 A Vtrans = 5.751030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:34:03 Magnet Current Measurement: Imag = 575.1005 +- 0.0025 A 14:34:03 Magnetic Field Measurement Measuring the magnet strength... 14:34:03 Integrated Voltage Measurement... 14:34:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013717157 Vs 14:34:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014031356 Vs 14:34:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013702749 Vs 14:34:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014041576 Vs 14:34:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013698280 Vs 14:35:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014039821 Vs 14:35:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013700833 Vs 14:35:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014033443 Vs 14:35:31 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013870652 +- 0.000002747 Vs 14:35:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.013870652 +- 0.000002747 Vs BL = 1.38706520 +- 0.00027471 Tm 14:35:34 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.38707 0.00027 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.38707 0.00027 1.38707 0.00000 14:35:34 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.38707 0.00027 SL = 1.3870652 +- 0.0002747 Tm^2/m^n 14:35:34 Magnet Strength Measurement Harmonic Number = 1 SL = 1.3870652 +- 0.0002747 Tm^2/m^n 14:35:35 Magnet Current, Imag = 575.1120 A Vtrans = 5.751120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:37 Magnet Current, Imag = 575.1030 A Vtrans = 5.751030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:39 Magnet Current, Imag = 575.0990 A Vtrans = 5.750990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:40 Magnet Current, Imag = 575.1100 A Vtrans = 5.751100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:40 Magnet Current Measurement: Imag = 575.1060 +- 0.0052 A 14:35:40 Magnet current ramping to 600.0000 A... 14:35:56 Magnet Current, Imag = 600.1290 A Vtrans = 6.001290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:57 Magnet Current, Imag = 600.1260 A Vtrans = 6.001260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:59 Magnet Current, Imag = 600.1330 A Vtrans = 6.001330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:36:01 Magnet Current, Imag = 600.1280 A Vtrans = 6.001280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:36:01 Magnet Current Measurement: Imag = 600.1290 +- 0.0025 A 14:36:01 Magnetic Field Measurement Measuring the magnet strength... 14:36:01 Integrated Voltage Measurement... 14:36:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014277395 Vs 14:36:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014617053 Vs 14:36:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014269851 Vs 14:36:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014604706 Vs 14:36:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014277893 Vs 14:37:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014610712 Vs 14:37:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014275444 Vs 14:37:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014614874 Vs 14:37:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014443491 +- 0.000003741 Vs 14:37:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014443491 +- 0.000003741 Vs BL = 1.44434910 +- 0.00037406 Tm 14:37:31 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.44435 0.00037 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.44435 0.00037 1.44435 0.00000 14:37:31 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.44435 0.00037 SL = 1.4443491 +- 0.0003741 Tm^2/m^n 14:37:31 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4443491 +- 0.0003741 Tm^2/m^n 14:37:33 Magnet Current, Imag = 600.1230 A Vtrans = 6.001230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:34 Magnet Current, Imag = 600.1480 A Vtrans = 6.001480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:36 Magnet Current, Imag = 600.1610 A Vtrans = 6.001610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:37 Magnet Current, Imag = 600.1560 A Vtrans = 6.001560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:37 Magnet Current Measurement: Imag = 600.1470 +- 0.0146 A 14:37:37 Magnet current ramping to 625.0000 A... 14:37:53 Magnet Current, Imag = 625.1820 A Vtrans = 6.251820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:55 Magnet Current, Imag = 625.1970 A Vtrans = 6.251970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:56 Magnet Current, Imag = 625.1670 A Vtrans = 6.251670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:58 Magnet Current, Imag = 625.1650 A Vtrans = 6.251650 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:58 Magnet Current Measurement: Imag = 625.1777 +- 0.0129 A 14:37:58 Magnetic Field Measurement Measuring the magnet strength... 14:37:58 Integrated Voltage Measurement... 14:38:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014837182 Vs 14:38:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015175953 Vs 14:38:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014837141 Vs 14:38:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015158565 Vs 14:38:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014844802 Vs 14:39:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015167779 Vs 14:39:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014833609 Vs 14:39:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015164521 Vs 14:39:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015002444 +- 0.000004009 Vs 14:39:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015002444 +- 0.000004009 Vs BL = 1.50024442 +- 0.00040090 Tm 14:39:29 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.50024 0.00040 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.50024 0.00040 1.50024 0.00000 14:39:29 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.50024 0.00040 SL = 1.5002444 +- 0.0004009 Tm^2/m^n 14:39:29 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5002444 +- 0.0004009 Tm^2/m^n 14:39:30 Magnet Current, Imag = 625.1800 A Vtrans = 6.251800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:32 Magnet Current, Imag = 625.1800 A Vtrans = 6.251800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:33 Magnet Current, Imag = 625.1740 A Vtrans = 6.251740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:35 Magnet Current, Imag = 625.1930 A Vtrans = 6.251930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:35 Magnet Current Measurement: Imag = 625.1817 +- 0.0069 A 14:39:35 Magnet current ramping to 650.0000 A... 14:39:51 Magnet Current, Imag = 650.2150 A Vtrans = 6.502150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:52 Magnet Current, Imag = 650.2320 A Vtrans = 6.502320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:54 Magnet Current, Imag = 650.2010 A Vtrans = 6.502010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:55 Magnet Current, Imag = 650.2170 A Vtrans = 6.502170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:55 Magnet Current Measurement: Imag = 650.2162 +- 0.0110 A 14:39:55 Magnetic Field Measurement Measuring the magnet strength... 14:39:55 Integrated Voltage Measurement... 14:40:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015370963 Vs 14:40:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015702413 Vs 14:40:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015374677 Vs 14:40:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015696928 Vs 14:40:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015383053 Vs 14:41:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015689317 Vs 14:41:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015386063 Vs 14:41:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015689981 Vs 14:41:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015536674 +- 0.000000839 Vs 14:41:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015536674 +- 0.000000839 Vs BL = 1.55366744 +- 0.00008389 Tm 14:41:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.55367 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.55367 0.00008 1.55367 0.00000 14:41:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.55367 0.00008 SL = 1.5536674 +- 0.0000839 Tm^2/m^n 14:41:26 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5536674 +- 0.0000839 Tm^2/m^n 14:41:27 Magnet Current, Imag = 650.2040 A Vtrans = 6.502040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:41:29 Magnet Current, Imag = 650.2120 A Vtrans = 6.502120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:41:30 Magnet Current, Imag = 650.1910 A Vtrans = 6.501910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:41:32 Magnet Current, Imag = 650.1900 A Vtrans = 6.501900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:41:32 Magnet Current Measurement: Imag = 650.1993 +- 0.0092 A 14:41:32 Magnet current ramping to 675.0000 A... 14:41:48 Magnet Current, Imag = 675.2390 A Vtrans = 6.752390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:41:49 Magnet Current, Imag = 675.2570 A Vtrans = 6.752570 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:41:51 Magnet Current, Imag = 675.2110 A Vtrans = 6.752110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:41:52 Magnet Current, Imag = 675.2470 A Vtrans = 6.752470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:41:52 Magnet Current Measurement: Imag = 675.2385 +- 0.0171 A 14:41:52 Magnetic Field Measurement Measuring the magnet strength... 14:41:52 Integrated Voltage Measurement... 14:42:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015877485 Vs 14:42:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016188412 Vs 14:42:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015877943 Vs 14:42:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016199458 Vs 14:42:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015878799 Vs 14:42:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016193721 Vs 14:43:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015872701 Vs 14:43:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016199523 Vs 14:43:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016036005 +- 0.000002042 Vs 14:43:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016036005 +- 0.000002042 Vs BL = 1.60360052 +- 0.00020423 Tm 14:43:23 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.60360 0.00020 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.60360 0.00020 1.60360 0.00000 14:43:23 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.60360 0.00020 SL = 1.6036005 +- 0.0002042 Tm^2/m^n 14:43:23 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6036005 +- 0.0002042 Tm^2/m^n 14:43:24 Magnet Current, Imag = 675.2560 A Vtrans = 6.752560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:26 Magnet Current, Imag = 675.2460 A Vtrans = 6.752460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:28 Magnet Current, Imag = 675.2250 A Vtrans = 6.752250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:29 Magnet Current, Imag = 675.2280 A Vtrans = 6.752280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:29 Magnet Current Measurement: Imag = 675.2387 +- 0.0128 A 14:43:29 Magnet current ramping to 700.0000 A... 14:43:45 Magnet Current, Imag = 700.2610 A Vtrans = 7.002610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:46 Magnet Current, Imag = 700.2580 A Vtrans = 7.002580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:48 Magnet Current, Imag = 700.2360 A Vtrans = 7.002360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:50 Magnet Current, Imag = 700.2310 A Vtrans = 7.002310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:50 Magnet Current Measurement: Imag = 700.2465 +- 0.0132 A 14:43:50 Magnetic Field Measurement Measuring the magnet strength... 14:43:50 Integrated Voltage Measurement... 14:44:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016363463 Vs 14:44:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016663642 Vs 14:44:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016348005 Vs 14:44:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016660230 Vs 14:44:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016346032 Vs 14:44:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016662419 Vs 14:45:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016339408 Vs 14:45:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016664443 Vs 14:45:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016505955 +- 0.000004481 Vs 14:45:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016505955 +- 0.000004481 Vs BL = 1.65059553 +- 0.00044811 Tm 14:45:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.65060 0.00045 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.65060 0.00045 1.65060 0.00000 14:45:20 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.65060 0.00045 SL = 1.6505955 +- 0.0004481 Tm^2/m^n 14:45:20 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6505955 +- 0.0004481 Tm^2/m^n 14:45:22 Magnet Current, Imag = 700.2480 A Vtrans = 7.002480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:24 Magnet Current, Imag = 700.2430 A Vtrans = 7.002430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:25 Magnet Current, Imag = 700.2670 A Vtrans = 7.002670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:27 Magnet Current, Imag = 700.2650 A Vtrans = 7.002650 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:27 Magnet Current Measurement: Imag = 700.2557 +- 0.0104 A 14:45:27 Magnet current ramping to 650.0000 A... 14:45:50 Magnet Current, Imag = 650.1920 A Vtrans = 6.501920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:51 Magnet Current, Imag = 650.2120 A Vtrans = 6.502120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:53 Magnet Current, Imag = 650.2260 A Vtrans = 6.502260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:54 Magnet Current, Imag = 650.1950 A Vtrans = 6.501950 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:54 Magnet Current Measurement: Imag = 650.2062 +- 0.0137 A 14:45:54 Magnetic Field Measurement Measuring the magnet strength... 14:45:54 Integrated Voltage Measurement... 14:46:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015432750 Vs 14:46:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015763052 Vs 14:46:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015439590 Vs 14:46:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015751639 Vs 14:46:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015443644 Vs 14:47:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015745922 Vs 14:47:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015439394 Vs 14:47:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015757037 Vs 14:47:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015596629 +- 0.000001464 Vs 14:47:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015596629 +- 0.000001464 Vs BL = 1.55966285 +- 0.00014640 Tm 14:47:25 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.55966 0.00015 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.55966 0.00015 1.55966 0.00000 14:47:25 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.55966 0.00015 SL = 1.5596629 +- 0.0001464 Tm^2/m^n 14:47:25 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5596629 +- 0.0001464 Tm^2/m^n 14:47:26 Magnet Current, Imag = 650.2330 A Vtrans = 6.502330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:47:28 Magnet Current, Imag = 650.2090 A Vtrans = 6.502090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:47:30 Magnet Current, Imag = 650.2170 A Vtrans = 6.502170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:47:31 Magnet Current, Imag = 650.2000 A Vtrans = 6.502000 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:47:31 Magnet Current Measurement: Imag = 650.2147 +- 0.0121 A 14:47:31 Magnet current ramping to 600.0000 A... 14:47:54 Magnet Current, Imag = 600.1310 A Vtrans = 6.001310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:47:56 Magnet Current, Imag = 600.1230 A Vtrans = 6.001230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:47:57 Magnet Current, Imag = 600.1270 A Vtrans = 6.001270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:47:59 Magnet Current, Imag = 600.1260 A Vtrans = 6.001260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:47:59 Magnet Current Measurement: Imag = 600.1267 +- 0.0029 A 14:47:59 Magnetic Field Measurement Measuring the magnet strength... 14:47:59 Integrated Voltage Measurement... 14:48:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014350637 Vs 14:48:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014669769 Vs 14:48:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014358055 Vs 14:48:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014665322 Vs 14:48:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014349021 Vs 14:49:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014672284 Vs 14:49:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014353235 Vs 14:49:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014673456 Vs 14:49:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014511472 +- 0.000001208 Vs 14:49:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014511472 +- 0.000001208 Vs BL = 1.45114723 +- 0.00012083 Tm 14:49:29 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.45115 0.00012 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.45115 0.00012 1.45115 0.00000 14:49:29 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.45115 0.00012 SL = 1.4511472 +- 0.0001208 Tm^2/m^n 14:49:29 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4511472 +- 0.0001208 Tm^2/m^n 14:49:31 Magnet Current, Imag = 600.1530 A Vtrans = 6.001530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:32 Magnet Current, Imag = 600.1290 A Vtrans = 6.001290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:34 Magnet Current, Imag = 600.1170 A Vtrans = 6.001170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:36 Magnet Current, Imag = 600.1270 A Vtrans = 6.001270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:36 Magnet Current Measurement: Imag = 600.1315 +- 0.0132 A 14:49:36 Magnet current ramping to 550.0000 A... 14:49:59 Magnet Current, Imag = 550.0580 A Vtrans = 5.500580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:50:00 Magnet Current, Imag = 550.0750 A Vtrans = 5.500750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:50:02 Magnet Current, Imag = 550.0950 A Vtrans = 5.500950 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:50:03 Magnet Current, Imag = 550.0890 A Vtrans = 5.500890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:50:03 Magnet Current Measurement: Imag = 550.0792 +- 0.0143 A 14:50:03 Magnetic Field Measurement Measuring the magnet strength... 14:50:03 Integrated Voltage Measurement... 14:50:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013186367 Vs 14:50:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013502682 Vs 14:50:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013182328 Vs 14:50:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013503643 Vs 14:50:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013174517 Vs 14:51:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013503926 Vs 14:51:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013182137 Vs 14:51:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013500797 Vs 14:51:31 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013342050 +- 0.000001958 Vs 14:51:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.013342050 +- 0.000001958 Vs BL = 1.33420497 +- 0.00019581 Tm 14:51:34 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.33420 0.00020 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.33420 0.00020 1.33420 0.00000 14:51:34 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.33420 0.00020 SL = 1.3342050 +- 0.0001958 Tm^2/m^n 14:51:34 Magnet Strength Measurement Harmonic Number = 1 SL = 1.3342050 +- 0.0001958 Tm^2/m^n 14:51:35 Magnet Current, Imag = 550.0770 A Vtrans = 5.500770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:51:37 Magnet Current, Imag = 550.0960 A Vtrans = 5.500960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:51:39 Magnet Current, Imag = 550.0920 A Vtrans = 5.500920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:51:40 Magnet Current, Imag = 550.0800 A Vtrans = 5.500800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:51:40 Magnet Current Measurement: Imag = 550.0862 +- 0.0079 A 14:51:40 Magnet current ramping to 500.0000 A... 14:52:03 Magnet Current, Imag = 500.0680 A Vtrans = 5.000680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:52:05 Magnet Current, Imag = 500.0750 A Vtrans = 5.000750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:52:06 Magnet Current, Imag = 500.0630 A Vtrans = 5.000630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:52:08 Magnet Current, Imag = 500.0690 A Vtrans = 5.000690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:52:08 Magnet Current Measurement: Imag = 500.0688 +- 0.0043 A 14:52:08 Magnetic Field Measurement Measuring the magnet strength... 14:52:08 Integrated Voltage Measurement... 14:52:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011994457 Vs 14:52:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012311417 Vs 14:52:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011986993 Vs 14:52:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012309661 Vs 14:53:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011979327 Vs 14:53:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012305186 Vs 14:53:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011985928 Vs 14:53:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012315321 Vs 14:53:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012148536 +- 0.000003975 Vs 14:53:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012148536 +- 0.000003975 Vs BL = 1.21485361 +- 0.00039749 Tm 14:53:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.21485 0.00040 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.21485 0.00040 1.21485 0.00000 14:53:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.21485 0.00040 SL = 1.2148536 +- 0.0003975 Tm^2/m^n 14:53:38 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2148536 +- 0.0003975 Tm^2/m^n 14:53:40 Magnet Current, Imag = 500.0680 A Vtrans = 5.000680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:53:42 Magnet Current, Imag = 500.0660 A Vtrans = 5.000660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:53:43 Magnet Current, Imag = 500.0560 A Vtrans = 5.000560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:53:45 Magnet Current, Imag = 500.0710 A Vtrans = 5.000710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:53:45 Magnet Current Measurement: Imag = 500.0652 +- 0.0056 A 14:53:45 Magnet current ramping to 450.0000 A... 14:54:08 Magnet Current, Imag = 450.0160 A Vtrans = 4.500160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:54:09 Magnet Current, Imag = 450.0130 A Vtrans = 4.500130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:54:11 Magnet Current, Imag = 449.9930 A Vtrans = 4.499930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:54:12 Magnet Current, Imag = 450.0090 A Vtrans = 4.500090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:54:12 Magnet Current Measurement: Imag = 450.0077 +- 0.0089 A 14:54:12 Magnetic Field Measurement Measuring the magnet strength... 14:54:12 Integrated Voltage Measurement... 14:54:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010773719 Vs 14:54:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011094351 Vs 14:54:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010776353 Vs 14:54:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011106082 Vs 14:55:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010771621 Vs 14:55:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011099566 Vs 14:55:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010771437 Vs 14:55:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011089801 Vs 14:55:40 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010935366 +- 0.000003828 Vs 14:55:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.010935366 +- 0.000003828 Vs BL = 1.09353662 +- 0.00038275 Tm 14:55:43 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.09354 0.00038 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.09354 0.00038 1.09354 0.00000 14:55:43 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.09354 0.00038 SL = 1.0935366 +- 0.0003828 Tm^2/m^n 14:55:43 Magnet Strength Measurement Harmonic Number = 1 SL = 1.0935366 +- 0.0003828 Tm^2/m^n 14:55:45 Magnet Current, Imag = 449.9860 A Vtrans = 4.499860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:55:46 Magnet Current, Imag = 449.9960 A Vtrans = 4.499960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:55:48 Magnet Current, Imag = 450.0050 A Vtrans = 4.500050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:55:49 Magnet Current, Imag = 450.0040 A Vtrans = 4.500040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:55:49 Magnet Current Measurement: Imag = 449.9977 +- 0.0076 A 14:55:49 Magnet current ramping to 400.0000 A... 14:56:12 Magnet Current, Imag = 399.9350 A Vtrans = 3.999350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:56:14 Magnet Current, Imag = 399.9250 A Vtrans = 3.999250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:56:15 Magnet Current, Imag = 399.9330 A Vtrans = 3.999330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:56:17 Magnet Current, Imag = 399.9190 A Vtrans = 3.999190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:56:17 Magnet Current Measurement: Imag = 399.9280 +- 0.0064 A 14:56:17 Magnetic Field Measurement Measuring the magnet strength... 14:56:17 Integrated Voltage Measurement... 14:56:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009567665 Vs 14:56:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009895457 Vs 14:56:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009566020 Vs 14:57:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009890225 Vs 14:57:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009564919 Vs 14:57:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009884695 Vs 14:57:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009559073 Vs 14:57:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009880661 Vs 14:57:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009726089 +- 0.000004314 Vs 14:57:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009726089 +- 0.000004314 Vs BL = 0.97260893 +- 0.00043138 Tm 14:57:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.97261 0.00043 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.97261 0.00043 0.97261 0.00000 14:57:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.97261 0.00043 SL = 0.9726089 +- 0.0004314 Tm^2/m^n 14:57:47 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9726089 +- 0.0004314 Tm^2/m^n 14:57:49 Magnet Current, Imag = 399.9520 A Vtrans = 3.999520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:57:50 Magnet Current, Imag = 399.9480 A Vtrans = 3.999480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:57:52 Magnet Current, Imag = 399.9430 A Vtrans = 3.999430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:57:54 Magnet Current, Imag = 399.9330 A Vtrans = 3.999330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:57:54 Magnet Current Measurement: Imag = 399.9440 +- 0.0071 A 14:58:24 Magnet current ramping to 0.0000 A...