SLAC Magnetic Measurements Date: 05-06-2002 Time: 10:16:10 Project: spear3 Magnet Type: gdipole Magnet Name: 109D-031 Serial Number: Run Number: 14 Measurement Device: stretched wire Operator: sa Comment: BL vs. I, Mains Standardization: 1 cycles from 0.0 A to 770.0 A to 0.0 A Test Currents (A): 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 500.0 525.0 550.0 575.0 600.0 625.0 650.0 675.0 700.0 650.0 600.0 550.0 500.0 450.0 400.0 10:16:18 Initial Zero Current Measurement, Imag_zero = 0.0000 A 10:16:18 Magnet current ramping to 15.0000 A... 10:16:50 Magnet current ramping to 770.0000 A... 10:21:06 Magnet current ramping to 0.0000 A... 10:25:55 Magnet current ramping to 50.0000 A... 10:26:19 Magnet Current, Imag = 59.4940 A Vtrans = 0.594940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:26:20 Magnet Current, Imag = 50.4083 A Vtrans = 0.504083 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:26:23 Magnet Current, Imag = 51.2463 A Vtrans = 0.512463 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:26:24 Magnet Current, Imag = 49.1265 A Vtrans = 0.491265 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:26:24 Magnet Current Measurement: Imag = 52.5688 +- 4.0689 A 10:26:24 Magnetic Field Measurement Measuring the magnet strength... 10:26:24 Integrated Voltage Measurement... 10:26:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001090491 Vs 10:26:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001331982 Vs 10:26:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001110355 Vs 10:27:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001326277 Vs 10:27:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001109315 Vs 10:27:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001320986 Vs 10:27:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001096379 Vs 10:27:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001325220 Vs 10:27:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001213876 +- 0.000003073 Vs 10:27:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001213876 +- 0.000003073 Vs BL = 0.12138757 +- 0.00030727 Tm 10:27:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.12139 0.00031 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.12139 0.00031 0.12139 0.00000 10:27:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.12139 0.00031 SL = 0.1213876 +- 0.0003073 Tm^2/m^n 10:27:55 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1213876 +- 0.0003073 Tm^2/m^n 10:27:56 Magnet Current, Imag = 49.7134 A Vtrans = 0.497134 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:27:58 Magnet Current, Imag = 49.7093 A Vtrans = 0.497093 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:27:59 Magnet Current, Imag = 49.6970 A Vtrans = 0.496970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:28:01 Magnet Current, Imag = 49.6951 A Vtrans = 0.496951 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:28:01 Magnet Current Measurement: Imag = 49.7037 +- 0.0078 A 10:28:01 Magnet current ramping to 100.0000 A... 10:28:24 Magnet Current, Imag = 99.7444 A Vtrans = 0.997444 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:28:25 Magnet Current, Imag = 99.7395 A Vtrans = 0.997395 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:28:27 Magnet Current, Imag = 99.7180 A Vtrans = 0.997180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:28:28 Magnet Current, Imag = 99.7200 A Vtrans = 0.997200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:28:28 Magnet Current Measurement: Imag = 99.7305 +- 0.0116 A 10:28:28 Magnetic Field Measurement Measuring the magnet strength... 10:28:28 Integrated Voltage Measurement... 10:28:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002301475 Vs 10:28:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002520473 Vs 10:29:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002295549 Vs 10:29:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002522887 Vs 10:29:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002295775 Vs 10:29:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002515314 Vs 10:29:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002299049 Vs 10:29:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002523116 Vs 10:29:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002409205 +- 0.000002239 Vs 10:29:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.002409205 +- 0.000002239 Vs BL = 0.24092048 +- 0.00022390 Tm 10:29:59 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.24092 0.00022 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.24092 0.00022 0.24092 0.00000 10:29:59 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.24092 0.00022 SL = 0.2409205 +- 0.0002239 Tm^2/m^n 10:29:59 Magnet Strength Measurement Harmonic Number = 1 SL = 0.2409205 +- 0.0002239 Tm^2/m^n 10:30:00 Magnet Current, Imag = 99.7277 A Vtrans = 0.997277 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:30:02 Magnet Current, Imag = 99.7193 A Vtrans = 0.997193 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:30:03 Magnet Current, Imag = 99.7405 A Vtrans = 0.997405 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:30:04 Magnet Current, Imag = 99.7328 A Vtrans = 0.997328 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:30:04 Magnet Current Measurement: Imag = 99.7301 +- 0.0077 A 10:30:04 Magnet current ramping to 150.0000 A... 10:30:27 Magnet Current, Imag = 149.7674 A Vtrans = 1.497674 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:30:29 Magnet Current, Imag = 149.7981 A Vtrans = 1.497981 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:30:30 Magnet Current, Imag = 149.7868 A Vtrans = 1.497868 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:30:32 Magnet Current, Imag = 149.7886 A Vtrans = 1.497886 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:30:32 Magnet Current Measurement: Imag = 149.7852 +- 0.0112 A 10:30:32 Magnetic Field Measurement Measuring the magnet strength... 10:30:32 Integrated Voltage Measurement... 10:30:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003510959 Vs 10:30:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003725643 Vs 10:31:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003502967 Vs 10:31:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003732408 Vs 10:31:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003509251 Vs 10:31:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003732849 Vs 10:31:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003519335 Vs 10:31:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003723910 Vs 10:31:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003619665 +- 0.000001697 Vs 10:31:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.003619665 +- 0.000001697 Vs BL = 0.36196653 +- 0.00016972 Tm 10:32:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.36197 0.00017 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.36197 0.00017 0.36197 0.00000 10:32:02 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.36197 0.00017 SL = 0.3619665 +- 0.0001697 Tm^2/m^n 10:32:02 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3619665 +- 0.0001697 Tm^2/m^n 10:32:04 Magnet Current, Imag = 149.7494 A Vtrans = 1.497494 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:32:05 Magnet Current, Imag = 149.7741 A Vtrans = 1.497741 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:32:07 Magnet Current, Imag = 149.7613 A Vtrans = 1.497613 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:32:08 Magnet Current, Imag = 149.7476 A Vtrans = 1.497476 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:32:08 Magnet Current Measurement: Imag = 149.7581 +- 0.0106 A 10:32:08 Magnet current ramping to 200.0000 A... 10:32:31 Magnet Current, Imag = 199.7769 A Vtrans = 1.997769 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:32:33 Magnet Current, Imag = 199.7757 A Vtrans = 1.997757 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:32:34 Magnet Current, Imag = 199.7496 A Vtrans = 1.997496 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:32:35 Magnet Current, Imag = 199.7655 A Vtrans = 1.997655 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:32:36 Magnet Current Measurement: Imag = 199.7669 +- 0.0109 A 10:32:36 Magnetic Field Measurement Measuring the magnet strength... 10:32:36 Integrated Voltage Measurement... 10:32:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004721399 Vs 10:32:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004939057 Vs 10:33:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004727545 Vs 10:33:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004939131 Vs 10:33:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004722371 Vs 10:33:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004936225 Vs 10:33:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004724296 Vs 10:34:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004946361 Vs 10:34:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004832048 +- 0.000002414 Vs 10:34:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004832048 +- 0.000002414 Vs BL = 0.48320479 +- 0.00024135 Tm 10:34:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.48320 0.00024 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.48320 0.00024 0.48320 0.00000 10:34:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.48320 0.00024 SL = 0.4832048 +- 0.0002414 Tm^2/m^n 10:34:06 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4832048 +- 0.0002414 Tm^2/m^n 10:34:08 Magnet Current, Imag = 199.8026 A Vtrans = 1.998026 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:34:09 Magnet Current, Imag = 199.7851 A Vtrans = 1.997851 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:34:10 Magnet Current, Imag = 199.7953 A Vtrans = 1.997953 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:34:12 Magnet Current, Imag = 199.7839 A Vtrans = 1.997839 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:34:12 Magnet Current Measurement: Imag = 199.7917 +- 0.0077 A 10:34:12 Magnet current ramping to 250.0000 A... 10:34:35 Magnet Current, Imag = 249.8324 A Vtrans = 2.498324 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:34:36 Magnet Current, Imag = 249.8133 A Vtrans = 2.498133 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:34:38 Magnet Current, Imag = 249.8362 A Vtrans = 2.498362 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:34:39 Magnet Current, Imag = 249.8288 A Vtrans = 2.498288 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:34:39 Magnet Current Measurement: Imag = 249.8277 +- 0.0087 A 10:34:39 Magnetic Field Measurement Measuring the magnet strength... 10:34:39 Integrated Voltage Measurement... 10:34:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005944281 Vs 10:35:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006165351 Vs 10:35:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005931243 Vs 10:35:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006159638 Vs 10:35:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005929362 Vs 10:35:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006158452 Vs 10:35:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005927833 Vs 10:36:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006166459 Vs 10:36:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006047827 +- 0.000004194 Vs 10:36:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006047827 +- 0.000004194 Vs BL = 0.60478272 +- 0.00041944 Tm 10:36:10 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.60478 0.00042 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.60478 0.00042 0.60478 0.00000 10:36:10 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.60478 0.00042 SL = 0.6047827 +- 0.0004194 Tm^2/m^n 10:36:10 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6047827 +- 0.0004194 Tm^2/m^n 10:36:11 Magnet Current, Imag = 249.8623 A Vtrans = 2.498623 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:36:13 Magnet Current, Imag = 249.8455 A Vtrans = 2.498455 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:36:14 Magnet Current, Imag = 249.8323 A Vtrans = 2.498323 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:36:15 Magnet Current, Imag = 249.8228 A Vtrans = 2.498228 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:36:16 Magnet Current Measurement: Imag = 249.8407 +- 0.0148 A 10:36:16 Magnet current ramping to 300.0000 A... 10:36:38 Magnet Current, Imag = 299.8769 A Vtrans = 2.998769 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:36:40 Magnet Current, Imag = 299.8921 A Vtrans = 2.998921 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:36:41 Magnet Current, Imag = 299.8945 A Vtrans = 2.998945 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:36:43 Magnet Current, Imag = 299.9114 A Vtrans = 2.999114 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:36:43 Magnet Current Measurement: Imag = 299.8937 +- 0.0122 A 10:36:43 Magnetic Field Measurement Measuring the magnet strength... 10:36:43 Integrated Voltage Measurement... 10:36:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007138416 Vs 10:37:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007356918 Vs 10:37:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007145455 Vs 10:37:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007364431 Vs 10:37:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007135132 Vs 10:37:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007362215 Vs 10:38:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007144368 Vs 10:38:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007364118 Vs 10:38:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007251382 +- 0.000003241 Vs 10:38:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.007251382 +- 0.000003241 Vs BL = 0.72513818 +- 0.00032406 Tm 10:38:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.72514 0.00032 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.72514 0.00032 0.72514 0.00000 10:38:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.72514 0.00032 SL = 0.7251382 +- 0.0003241 Tm^2/m^n 10:38:13 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7251382 +- 0.0003241 Tm^2/m^n 10:38:15 Magnet Current, Imag = 299.8478 A Vtrans = 2.998478 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:38:16 Magnet Current, Imag = 299.8443 A Vtrans = 2.998443 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:38:18 Magnet Current, Imag = 299.8217 A Vtrans = 2.998217 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:38:19 Magnet Current, Imag = 299.8379 A Vtrans = 2.998379 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:38:19 Magnet Current Measurement: Imag = 299.8379 +- 0.0100 A 10:38:19 Magnet current ramping to 350.0000 A... 10:38:43 Magnet Current, Imag = 349.9340 A Vtrans = 3.499340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:38:44 Magnet Current, Imag = 349.9100 A Vtrans = 3.499100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:38:46 Magnet Current, Imag = 349.8950 A Vtrans = 3.498950 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:38:48 Magnet Current, Imag = 349.9140 A Vtrans = 3.499140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:38:48 Magnet Current Measurement: Imag = 349.9133 +- 0.0139 A 10:38:48 Magnetic Field Measurement Measuring the magnet strength... 10:38:48 Integrated Voltage Measurement... 10:39:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008347741 Vs 10:39:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008584961 Vs 10:39:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008352024 Vs 10:39:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008570861 Vs 10:39:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008343410 Vs 10:39:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008573127 Vs 10:40:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008353491 Vs 10:40:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008567414 Vs 10:40:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008461629 +- 0.000002958 Vs 10:40:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.008461629 +- 0.000002958 Vs BL = 0.84616285 +- 0.00029583 Tm 10:40:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.84616 0.00030 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.84616 0.00030 0.84616 0.00000 10:40:20 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.84616 0.00030 SL = 0.8461629 +- 0.0002958 Tm^2/m^n 10:40:20 Magnet Strength Measurement Harmonic Number = 1 SL = 0.8461629 +- 0.0002958 Tm^2/m^n 10:40:22 Magnet Current, Imag = 349.8840 A Vtrans = 3.498840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:40:24 Magnet Current, Imag = 349.9050 A Vtrans = 3.499050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:40:26 Magnet Current, Imag = 349.9740 A Vtrans = 3.499740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:40:28 Magnet Current, Imag = 349.9460 A Vtrans = 3.499460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:40:28 Magnet Current Measurement: Imag = 349.9272 +- 0.0350 A 10:40:28 Magnet current ramping to 400.0000 A... 10:40:52 Magnet Current, Imag = 399.9120 A Vtrans = 3.999120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:40:54 Magnet Current, Imag = 399.9100 A Vtrans = 3.999100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:40:55 Magnet Current, Imag = 399.9390 A Vtrans = 3.999390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:40:57 Magnet Current, Imag = 399.9230 A Vtrans = 3.999230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:40:57 Magnet Current Measurement: Imag = 399.9210 +- 0.0115 A 10:40:57 Magnetic Field Measurement Measuring the magnet strength... 10:40:57 Integrated Voltage Measurement... 10:41:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009564133 Vs 10:41:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009784710 Vs 10:41:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009562385 Vs 10:41:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009782086 Vs 10:41:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009568094 Vs 10:42:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009805579 Vs 10:42:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009549637 Vs 10:42:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009784936 Vs 10:42:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009675195 +- 0.000007201 Vs 10:42:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009675195 +- 0.000007201 Vs BL = 0.96751949 +- 0.00072011 Tm 10:42:28 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.96752 0.00072 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.96752 0.00072 0.96752 0.00000 10:42:28 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.96752 0.00072 SL = 0.9675195 +- 0.0007201 Tm^2/m^n 10:42:28 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9675195 +- 0.0007201 Tm^2/m^n 10:42:30 Magnet Current, Imag = 399.9500 A Vtrans = 3.999500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:42:31 Magnet Current, Imag = 399.9150 A Vtrans = 3.999150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:42:33 Magnet Current, Imag = 399.9380 A Vtrans = 3.999380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:42:34 Magnet Current, Imag = 399.9450 A Vtrans = 3.999450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:42:34 Magnet Current Measurement: Imag = 399.9370 +- 0.0134 A 10:42:34 Magnet current ramping to 450.0000 A... 10:42:58 Magnet Current, Imag = 449.9620 A Vtrans = 4.499620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:43:00 Magnet Current, Imag = 449.9740 A Vtrans = 4.499740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:43:01 Magnet Current, Imag = 449.9760 A Vtrans = 4.499760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:43:03 Magnet Current, Imag = 449.9810 A Vtrans = 4.499810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:43:03 Magnet Current Measurement: Imag = 449.9732 +- 0.0070 A 10:43:03 Magnetic Field Measurement Measuring the magnet strength... 10:43:03 Integrated Voltage Measurement... 10:43:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010775815 Vs 10:43:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.010983019 Vs 10:43:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010769432 Vs 10:43:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.010995281 Vs 10:44:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010761432 Vs 10:44:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.010994577 Vs 10:44:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010763707 Vs 10:44:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.010989834 Vs 10:44:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010879137 +- 0.000002081 Vs 10:44:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.010879137 +- 0.000002081 Vs BL = 1.08791371 +- 0.00020813 Tm 10:44:37 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.08791 0.00021 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.08791 0.00021 1.08791 0.00000 10:44:37 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.08791 0.00021 SL = 1.0879137 +- 0.0002081 Tm^2/m^n 10:44:38 Magnet Strength Measurement Harmonic Number = 1 SL = 1.0879137 +- 0.0002081 Tm^2/m^n 10:44:39 Magnet Current, Imag = 449.9420 A Vtrans = 4.499420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:44:41 Magnet Current, Imag = 449.9510 A Vtrans = 4.499510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:44:42 Magnet Current, Imag = 449.9480 A Vtrans = 4.499480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:44:44 Magnet Current, Imag = 449.9230 A Vtrans = 4.499230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:44:44 Magnet Current Measurement: Imag = 449.9410 +- 0.0109 A 10:44:44 Magnet current ramping to 500.0000 A... 10:45:07 Magnet Current, Imag = 500.0050 A Vtrans = 5.000050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:45:08 Magnet Current, Imag = 499.9760 A Vtrans = 4.999760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:45:10 Magnet Current, Imag = 499.9840 A Vtrans = 4.999840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:45:11 Magnet Current, Imag = 499.9890 A Vtrans = 4.999890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:45:11 Magnet Current Measurement: Imag = 499.9885 +- 0.0106 A 10:45:12 Magnetic Field Measurement Measuring the magnet strength... 10:45:12 Integrated Voltage Measurement... 10:45:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011980108 Vs 10:45:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012200673 Vs 10:45:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011961511 Vs 10:45:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012197407 Vs 10:46:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011966788 Vs 10:46:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012192945 Vs 10:46:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011967082 Vs 10:46:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012198623 Vs 10:46:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012083142 +- 0.000004385 Vs 10:46:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012083142 +- 0.000004385 Vs BL = 1.20831421 +- 0.00043853 Tm 10:46:42 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.20831 0.00044 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.20831 0.00044 1.20831 0.00000 10:46:42 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.20831 0.00044 SL = 1.2083142 +- 0.0004385 Tm^2/m^n 10:46:42 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2083142 +- 0.0004385 Tm^2/m^n 10:46:44 Magnet Current, Imag = 499.9860 A Vtrans = 4.999860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:46:45 Magnet Current, Imag = 499.9870 A Vtrans = 4.999870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:46:47 Magnet Current, Imag = 499.9880 A Vtrans = 4.999880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:46:48 Magnet Current, Imag = 499.9910 A Vtrans = 4.999910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:46:49 Magnet Current Measurement: Imag = 499.9880 +- 0.0019 A 10:46:49 Magnet current ramping to 525.0000 A... 10:47:05 Magnet Current, Imag = 525.0760 A Vtrans = 5.250760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:47:07 Magnet Current, Imag = 525.0450 A Vtrans = 5.250450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:47:08 Magnet Current, Imag = 525.0390 A Vtrans = 5.250390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:47:10 Magnet Current, Imag = 525.0360 A Vtrans = 5.250360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:47:10 Magnet Current Measurement: Imag = 525.0490 +- 0.0159 A 10:47:10 Magnetic Field Measurement Measuring the magnet strength... 10:47:10 Integrated Voltage Measurement... 10:47:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012556936 Vs 10:47:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012785327 Vs 10:47:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012552482 Vs 10:47:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012786006 Vs 10:48:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012567580 Vs 10:48:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012781817 Vs 10:48:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012571047 Vs 10:48:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012780787 Vs 10:48:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012672748 +- 0.000002680 Vs 10:48:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012672748 +- 0.000002680 Vs BL = 1.26727478 +- 0.00026804 Tm 10:48:40 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.26727 0.00027 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.26727 0.00027 1.26727 0.00000 10:48:40 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.26727 0.00027 SL = 1.2672748 +- 0.0002680 Tm^2/m^n 10:48:41 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2672748 +- 0.0002680 Tm^2/m^n 10:48:42 Magnet Current, Imag = 524.9760 A Vtrans = 5.249760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:48:44 Magnet Current, Imag = 525.0170 A Vtrans = 5.250170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:48:45 Magnet Current, Imag = 525.0010 A Vtrans = 5.250010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:48:47 Magnet Current, Imag = 525.0140 A Vtrans = 5.250140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:48:47 Magnet Current Measurement: Imag = 525.0020 +- 0.0162 A 10:48:47 Magnet current ramping to 550.0000 A... 10:49:03 Magnet Current, Imag = 550.0040 A Vtrans = 5.500040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:49:05 Magnet Current, Imag = 549.9950 A Vtrans = 5.499950 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:49:06 Magnet Current, Imag = 549.9990 A Vtrans = 5.499990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:49:08 Magnet Current, Imag = 549.9760 A Vtrans = 5.499760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:49:08 Magnet Current Measurement: Imag = 549.9935 +- 0.0106 A 10:49:08 Magnetic Field Measurement Measuring the magnet strength... 10:49:08 Integrated Voltage Measurement... 10:49:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013149131 Vs 10:49:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013377381 Vs 10:49:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013145094 Vs 10:49:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013389983 Vs 10:50:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013157784 Vs 10:50:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013385004 Vs 10:50:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013149444 Vs 10:50:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013388177 Vs 10:50:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013267750 +- 0.000002943 Vs 10:50:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.013267750 +- 0.000002943 Vs BL = 1.32677498 +- 0.00029430 Tm 10:50:39 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.32677 0.00029 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.32677 0.00029 1.32677 0.00000 10:50:39 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.32677 0.00029 SL = 1.3267750 +- 0.0002943 Tm^2/m^n 10:50:39 Magnet Strength Measurement Harmonic Number = 1 SL = 1.3267750 +- 0.0002943 Tm^2/m^n 10:50:41 Magnet Current, Imag = 550.0220 A Vtrans = 5.500220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:42 Magnet Current, Imag = 550.0110 A Vtrans = 5.500110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:44 Magnet Current, Imag = 550.0240 A Vtrans = 5.500240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:45 Magnet Current, Imag = 550.0200 A Vtrans = 5.500200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:45 Magnet Current Measurement: Imag = 550.0192 +- 0.0050 A 10:50:45 Magnet current ramping to 575.0000 A... 10:51:01 Magnet Current, Imag = 575.0470 A Vtrans = 5.750470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:51:02 Magnet Current, Imag = 575.0370 A Vtrans = 5.750370 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:51:04 Magnet Current, Imag = 575.0400 A Vtrans = 5.750400 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:51:06 Magnet Current, Imag = 575.0200 A Vtrans = 5.750200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:51:06 Magnet Current Measurement: Imag = 575.0360 +- 0.0099 A 10:51:06 Magnetic Field Measurement Measuring the magnet strength... 10:51:06 Integrated Voltage Measurement... 10:51:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013725061 Vs 10:51:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013981426 Vs 10:51:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013736199 Vs 10:51:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013962563 Vs 10:52:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013737039 Vs 10:52:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013972797 Vs 10:52:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013733639 Vs 10:52:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013969459 Vs 10:52:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013852273 +- 0.000002051 Vs 10:52:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.013852273 +- 0.000002051 Vs BL = 1.38522729 +- 0.00020508 Tm 10:52:37 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.38523 0.00021 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.38523 0.00021 1.38523 0.00000 10:52:37 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.38523 0.00021 SL = 1.3852273 +- 0.0002051 Tm^2/m^n 10:52:37 Magnet Strength Measurement Harmonic Number = 1 SL = 1.3852273 +- 0.0002051 Tm^2/m^n 10:52:39 Magnet Current, Imag = 575.0390 A Vtrans = 5.750390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:52:40 Magnet Current, Imag = 575.0520 A Vtrans = 5.750520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:52:42 Magnet Current, Imag = 575.0580 A Vtrans = 5.750580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:52:43 Magnet Current, Imag = 575.0450 A Vtrans = 5.750450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:52:43 Magnet Current Measurement: Imag = 575.0485 +- 0.0072 A 10:52:44 Magnet current ramping to 600.0000 A... 10:52:59 Magnet Current, Imag = 600.0640 A Vtrans = 6.000640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:53:01 Magnet Current, Imag = 600.0710 A Vtrans = 6.000710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:53:02 Magnet Current, Imag = 600.0970 A Vtrans = 6.000970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:53:04 Magnet Current, Imag = 600.0680 A Vtrans = 6.000680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:53:04 Magnet Current Measurement: Imag = 600.0750 +- 0.0129 A 10:53:04 Magnetic Field Measurement Measuring the magnet strength... 10:53:04 Integrated Voltage Measurement... 10:53:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014304193 Vs 10:53:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014542751 Vs 10:53:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014315084 Vs 10:53:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014547450 Vs 10:54:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014306091 Vs 10:54:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014552640 Vs 10:54:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014310958 Vs 10:54:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014550787 Vs 10:54:32 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014428744 +- 0.000003126 Vs 10:54:32 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014428744 +- 0.000003126 Vs BL = 1.44287442 +- 0.00031255 Tm 10:54:35 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.44287 0.00031 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.44287 0.00031 1.44287 0.00000 10:54:35 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.44287 0.00031 SL = 1.4428744 +- 0.0003126 Tm^2/m^n 10:54:35 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4428744 +- 0.0003126 Tm^2/m^n 10:54:37 Magnet Current, Imag = 600.0790 A Vtrans = 6.000790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:38 Magnet Current, Imag = 600.0610 A Vtrans = 6.000610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:40 Magnet Current, Imag = 600.0690 A Vtrans = 6.000690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:41 Magnet Current, Imag = 600.0770 A Vtrans = 6.000770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:41 Magnet Current Measurement: Imag = 600.0715 +- 0.0071 A 10:54:41 Magnet current ramping to 625.0000 A... 10:54:57 Magnet Current, Imag = 625.0650 A Vtrans = 6.250650 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:54:59 Magnet Current, Imag = 625.0700 A Vtrans = 6.250700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:55:00 Magnet Current, Imag = 625.0810 A Vtrans = 6.250810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:55:02 Magnet Current, Imag = 625.1180 A Vtrans = 6.251180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:55:02 Magnet Current Measurement: Imag = 625.0835 +- 0.0207 A 10:55:02 Magnetic Field Measurement Measuring the magnet strength... 10:55:02 Integrated Voltage Measurement... 10:55:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014860915 Vs 10:55:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015111791 Vs 10:55:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014857843 Vs 10:55:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015098801 Vs 10:55:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014863825 Vs 10:56:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015096845 Vs 10:56:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014858707 Vs 10:56:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015098287 Vs 10:56:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014980877 +- 0.000003259 Vs 10:56:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014980877 +- 0.000003259 Vs BL = 1.49808768 +- 0.00032586 Tm 10:56:33 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.49809 0.00033 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.49809 0.00033 1.49809 0.00000 10:56:33 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.49809 0.00033 SL = 1.4980877 +- 0.0003259 Tm^2/m^n 10:56:33 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4980877 +- 0.0003259 Tm^2/m^n 10:56:34 Magnet Current, Imag = 625.0330 A Vtrans = 6.250330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:36 Magnet Current, Imag = 625.0860 A Vtrans = 6.250860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:37 Magnet Current, Imag = 625.0720 A Vtrans = 6.250720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:39 Magnet Current, Imag = 625.0820 A Vtrans = 6.250820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:39 Magnet Current Measurement: Imag = 625.0682 +- 0.0210 A 10:56:39 Magnet current ramping to 650.0000 A... 10:56:55 Magnet Current, Imag = 650.1250 A Vtrans = 6.501250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:56 Magnet Current, Imag = 650.0900 A Vtrans = 6.500900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:58 Magnet Current, Imag = 650.0930 A Vtrans = 6.500930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:59 Magnet Current, Imag = 650.0360 A Vtrans = 6.500360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:56:59 Magnet Current Measurement: Imag = 650.0860 +- 0.0320 A 10:56:59 Magnetic Field Measurement Measuring the magnet strength... 10:56:59 Integrated Voltage Measurement... 10:57:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015392929 Vs 10:57:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015632949 Vs 10:57:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015396793 Vs 10:57:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015631823 Vs 10:57:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015393007 Vs 10:58:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015638404 Vs 10:58:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015403597 Vs 10:58:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015636735 Vs 10:58:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015515780 +- 0.000002715 Vs 10:58:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015515780 +- 0.000002715 Vs BL = 1.55157797 +- 0.00027148 Tm 10:58:31 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.55158 0.00027 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.55158 0.00027 1.55158 0.00000 10:58:31 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.55158 0.00027 SL = 1.5515780 +- 0.0002715 Tm^2/m^n 10:58:31 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5515780 +- 0.0002715 Tm^2/m^n 10:58:32 Magnet Current, Imag = 650.1060 A Vtrans = 6.501060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:34 Magnet Current, Imag = 650.1260 A Vtrans = 6.501260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:36 Magnet Current, Imag = 650.1330 A Vtrans = 6.501330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:37 Magnet Current, Imag = 650.1270 A Vtrans = 6.501270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:37 Magnet Current Measurement: Imag = 650.1230 +- 0.0102 A 10:58:37 Magnet current ramping to 675.0000 A... 10:58:53 Magnet Current, Imag = 675.1180 A Vtrans = 6.751180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:54 Magnet Current, Imag = 675.1520 A Vtrans = 6.751520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:56 Magnet Current, Imag = 675.1260 A Vtrans = 6.751260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:58 Magnet Current, Imag = 675.1320 A Vtrans = 6.751320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:58:58 Magnet Current Measurement: Imag = 675.1320 +- 0.0126 A 10:58:58 Magnetic Field Measurement Measuring the magnet strength... 10:58:58 Integrated Voltage Measurement... 10:59:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015893097 Vs 10:59:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016126508 Vs 10:59:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015888133 Vs 10:59:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016128163 Vs 10:59:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015873291 Vs 11:00:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016136051 Vs 11:00:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015888973 Vs 11:00:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016133523 Vs 11:00:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016008468 +- 0.000002451 Vs 11:00:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016008468 +- 0.000002451 Vs BL = 1.60084675 +- 0.00024508 Tm 11:00:28 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.60085 0.00025 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.60085 0.00025 1.60085 0.00000 11:00:28 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.60085 0.00025 SL = 1.6008468 +- 0.0002451 Tm^2/m^n 11:00:28 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6008468 +- 0.0002451 Tm^2/m^n 11:00:30 Magnet Current, Imag = 675.1830 A Vtrans = 6.751830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:31 Magnet Current, Imag = 675.1110 A Vtrans = 6.751110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:33 Magnet Current, Imag = 675.1130 A Vtrans = 6.751130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:35 Magnet Current, Imag = 675.1190 A Vtrans = 6.751190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:35 Magnet Current Measurement: Imag = 675.1315 +- 0.0299 A 11:00:35 Magnet current ramping to 700.0000 A... 11:00:50 Magnet Current, Imag = 700.1620 A Vtrans = 7.001620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:52 Magnet Current, Imag = 700.1800 A Vtrans = 7.001800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:53 Magnet Current, Imag = 700.1500 A Vtrans = 7.001500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:55 Magnet Current, Imag = 700.1770 A Vtrans = 7.001770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:55 Magnet Current Measurement: Imag = 700.1672 +- 0.0121 A 11:00:55 Magnetic Field Measurement Measuring the magnet strength... 11:00:55 Integrated Voltage Measurement... 11:01:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016355150 Vs 11:01:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016604411 Vs 11:01:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016355503 Vs 11:01:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016597982 Vs 11:01:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016360633 Vs 11:02:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016601659 Vs 11:02:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016361671 Vs 11:02:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016604509 Vs 11:02:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016480190 +- 0.000002312 Vs 11:02:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016480190 +- 0.000002312 Vs BL = 1.64801898 +- 0.00023118 Tm 11:02:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.64802 0.00023 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.64802 0.00023 1.64802 0.00000 11:02:27 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.64802 0.00023 SL = 1.6480190 +- 0.0002312 Tm^2/m^n 11:02:27 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6480190 +- 0.0002312 Tm^2/m^n 11:02:28 Magnet Current, Imag = 700.1540 A Vtrans = 7.001540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:30 Magnet Current, Imag = 700.1530 A Vtrans = 7.001530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:31 Magnet Current, Imag = 700.1690 A Vtrans = 7.001690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:33 Magnet Current, Imag = 700.1680 A Vtrans = 7.001680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:33 Magnet Current Measurement: Imag = 700.1610 +- 0.0075 A 11:02:33 Magnet current ramping to 650.0000 A... 11:02:56 Magnet Current, Imag = 650.0760 A Vtrans = 6.500760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:58 Magnet Current, Imag = 650.0630 A Vtrans = 6.500630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:59 Magnet Current, Imag = 650.1150 A Vtrans = 6.501150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:03:01 Magnet Current, Imag = 650.1360 A Vtrans = 6.501360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:03:01 Magnet Current Measurement: Imag = 650.0975 +- 0.0293 A 11:03:01 Magnetic Field Measurement Measuring the magnet strength... 11:03:01 Integrated Voltage Measurement... 11:03:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015451507 Vs 11:03:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015694629 Vs 11:03:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015453243 Vs 11:03:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015683305 Vs 11:03:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015457685 Vs 11:04:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015698608 Vs 11:04:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015468993 Vs 11:04:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015690856 Vs 11:04:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015574853 +- 0.000004556 Vs 11:04:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015574853 +- 0.000004556 Vs BL = 1.55748532 +- 0.00045561 Tm 11:04:31 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.55749 0.00046 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.55749 0.00046 1.55749 0.00000 11:04:31 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.55749 0.00046 SL = 1.5574853 +- 0.0004556 Tm^2/m^n 11:04:31 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5574853 +- 0.0004556 Tm^2/m^n 11:04:33 Magnet Current, Imag = 650.1400 A Vtrans = 6.501400 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:35 Magnet Current, Imag = 650.1200 A Vtrans = 6.501200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:36 Magnet Current, Imag = 650.1130 A Vtrans = 6.501130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:38 Magnet Current, Imag = 650.1010 A Vtrans = 6.501010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:38 Magnet Current Measurement: Imag = 650.1185 +- 0.0142 A 11:04:38 Magnet current ramping to 600.0000 A... 11:05:01 Magnet Current, Imag = 600.0190 A Vtrans = 6.000190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:05:02 Magnet Current, Imag = 600.0440 A Vtrans = 6.000440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:05:04 Magnet Current, Imag = 600.0520 A Vtrans = 6.000520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:05:05 Magnet Current, Imag = 600.0670 A Vtrans = 6.000670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:05:05 Magnet Current Measurement: Imag = 600.0455 +- 0.0174 A 11:05:05 Magnetic Field Measurement Measuring the magnet strength... 11:05:06 Integrated Voltage Measurement... 11:05:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014359957 Vs 11:05:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014613452 Vs 11:05:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014371936 Vs 11:05:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014606495 Vs 11:06:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014365051 Vs 11:06:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014613240 Vs 11:06:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014364804 Vs 11:06:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014621185 Vs 11:06:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014489515 +- 0.000002249 Vs 11:06:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014489515 +- 0.000002249 Vs BL = 1.44895150 +- 0.00022490 Tm 11:06:36 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.44895 0.00022 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.44895 0.00022 1.44895 0.00000 11:06:36 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.44895 0.00022 SL = 1.4489515 +- 0.0002249 Tm^2/m^n 11:06:36 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4489515 +- 0.0002249 Tm^2/m^n 11:06:38 Magnet Current, Imag = 600.0460 A Vtrans = 6.000460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:39 Magnet Current, Imag = 600.0470 A Vtrans = 6.000470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:41 Magnet Current, Imag = 600.0240 A Vtrans = 6.000240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:42 Magnet Current, Imag = 600.0450 A Vtrans = 6.000450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:42 Magnet Current Measurement: Imag = 600.0405 +- 0.0096 A 11:06:43 Magnet current ramping to 550.0000 A... 11:07:06 Magnet Current, Imag = 550.0100 A Vtrans = 5.500100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:07:07 Magnet Current, Imag = 550.0010 A Vtrans = 5.500010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:07:09 Magnet Current, Imag = 550.0320 A Vtrans = 5.500320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:07:10 Magnet Current, Imag = 550.0310 A Vtrans = 5.500310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:07:10 Magnet Current Measurement: Imag = 550.0185 +- 0.0134 A 11:07:10 Magnetic Field Measurement Measuring the magnet strength... 11:07:10 Integrated Voltage Measurement... 11:07:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013205719 Vs 11:07:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013442017 Vs 11:07:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013206095 Vs 11:07:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013435748 Vs 11:08:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013202767 Vs 11:08:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013443589 Vs 11:08:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013210663 Vs 11:08:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013442345 Vs 11:08:38 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013323618 +- 0.000001991 Vs 11:08:38 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.013323618 +- 0.000001991 Vs BL = 1.33236177 +- 0.00019911 Tm 11:08:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.33236 0.00020 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.33236 0.00020 1.33236 0.00000 11:08:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.33236 0.00020 SL = 1.3323618 +- 0.0001991 Tm^2/m^n 11:08:41 Magnet Strength Measurement Harmonic Number = 1 SL = 1.3323618 +- 0.0001991 Tm^2/m^n 11:08:43 Magnet Current, Imag = 549.9830 A Vtrans = 5.499830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:08:44 Magnet Current, Imag = 549.9960 A Vtrans = 5.499960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:08:46 Magnet Current, Imag = 550.0020 A Vtrans = 5.500020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:08:47 Magnet Current, Imag = 550.0080 A Vtrans = 5.500080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:08:48 Magnet Current Measurement: Imag = 549.9972 +- 0.0093 A 11:08:48 Magnet current ramping to 500.0000 A... 11:09:11 Magnet Current, Imag = 499.9820 A Vtrans = 4.999820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:09:12 Magnet Current, Imag = 499.9820 A Vtrans = 4.999820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:09:14 Magnet Current, Imag = 499.9870 A Vtrans = 4.999870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:09:15 Magnet Current, Imag = 499.9730 A Vtrans = 4.999730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:09:15 Magnet Current Measurement: Imag = 499.9810 +- 0.0050 A 11:09:15 Magnetic Field Measurement Measuring the magnet strength... 11:09:15 Integrated Voltage Measurement... 11:09:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012015899 Vs 11:09:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012251598 Vs 11:09:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012010213 Vs 11:10:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012249343 Vs 11:10:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012004643 Vs 11:10:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012255185 Vs 11:10:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012016473 Vs 11:10:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012248448 Vs 11:10:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012131475 +- 0.000001692 Vs 11:10:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012131475 +- 0.000001692 Vs BL = 1.21314752 +- 0.00016923 Tm 11:10:46 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.21315 0.00017 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.21315 0.00017 1.21315 0.00000 11:10:46 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.21315 0.00017 SL = 1.2131475 +- 0.0001692 Tm^2/m^n 11:10:46 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2131475 +- 0.0001692 Tm^2/m^n 11:10:48 Magnet Current, Imag = 499.9980 A Vtrans = 4.999980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:10:49 Magnet Current, Imag = 499.9940 A Vtrans = 4.999940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:10:51 Magnet Current, Imag = 499.9840 A Vtrans = 4.999840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:10:52 Magnet Current, Imag = 500.0000 A Vtrans = 5.000000 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:10:52 Magnet Current Measurement: Imag = 499.9940 +- 0.0062 A 11:10:52 Magnet current ramping to 450.0000 A... 11:11:15 Magnet Current, Imag = 449.8800 A Vtrans = 4.498800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:11:17 Magnet Current, Imag = 449.8650 A Vtrans = 4.498650 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:11:18 Magnet Current, Imag = 449.8550 A Vtrans = 4.498550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:11:20 Magnet Current, Imag = 449.8720 A Vtrans = 4.498720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:11:20 Magnet Current Measurement: Imag = 449.8680 +- 0.0092 A 11:11:20 Magnetic Field Measurement Measuring the magnet strength... 11:11:20 Integrated Voltage Measurement... 11:11:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010808763 Vs 11:11:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011036144 Vs 11:11:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010800717 Vs 11:12:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011049030 Vs 11:12:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010803409 Vs 11:12:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011042536 Vs 11:12:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010806769 Vs 11:12:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011052201 Vs 11:12:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010924946 +- 0.000002771 Vs 11:12:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.010924946 +- 0.000002771 Vs BL = 1.09249461 +- 0.00027711 Tm 11:12:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.09249 0.00028 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.09249 0.00028 1.09249 0.00000 11:12:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.09249 0.00028 SL = 1.0924946 +- 0.0002771 Tm^2/m^n 11:12:52 Magnet Strength Measurement Harmonic Number = 1 SL = 1.0924946 +- 0.0002771 Tm^2/m^n 11:12:53 Magnet Current, Imag = 449.8990 A Vtrans = 4.498990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:12:55 Magnet Current, Imag = 449.9210 A Vtrans = 4.499210 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:12:56 Magnet Current, Imag = 449.9100 A Vtrans = 4.499100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:12:58 Magnet Current, Imag = 449.9270 A Vtrans = 4.499270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:12:58 Magnet Current Measurement: Imag = 449.9142 +- 0.0107 A 11:12:58 Magnet current ramping to 400.0000 A... 11:13:21 Magnet Current, Imag = 399.8780 A Vtrans = 3.998780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:13:23 Magnet Current, Imag = 399.8610 A Vtrans = 3.998610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:13:24 Magnet Current, Imag = 399.8640 A Vtrans = 3.998640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:13:26 Magnet Current, Imag = 399.8590 A Vtrans = 3.998590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:13:26 Magnet Current Measurement: Imag = 399.8655 +- 0.0074 A 11:13:26 Magnetic Field Measurement Measuring the magnet strength... 11:13:26 Integrated Voltage Measurement... 11:13:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009592193 Vs 11:13:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009834770 Vs 11:14:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009583776 Vs 11:14:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009828895 Vs 11:14:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009598794 Vs 11:14:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009832108 Vs 11:14:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009595052 Vs 11:14:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009828467 Vs 11:14:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009711757 +- 0.000003392 Vs 11:14:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009711757 +- 0.000003392 Vs BL = 0.97117570 +- 0.00033916 Tm 11:14:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.97118 0.00034 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.97118 0.00034 0.97118 0.00000 11:14:56 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.97118 0.00034 SL = 0.9711757 +- 0.0003392 Tm^2/m^n 11:14:56 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9711757 +- 0.0003392 Tm^2/m^n 11:14:58 Magnet Current, Imag = 399.8820 A Vtrans = 3.998820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:14:59 Magnet Current, Imag = 399.8640 A Vtrans = 3.998640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:15:01 Magnet Current, Imag = 399.8640 A Vtrans = 3.998640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:15:03 Magnet Current, Imag = 399.8620 A Vtrans = 3.998620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:15:03 Magnet Current Measurement: Imag = 399.8680 +- 0.0081 A 11:15:33 Magnet current ramping to 0.0000 A...