SLAC Magnetic Measurements Date: 12-13-2012 Time: 17:39:29 Project: SSRL Magnet Type: Undulator Magnet Name: BL5_EPU Serial Number: Run Number: 13 Measurement Device: 1wire Operator: sda Comment: VP- mode, Single Wire, 1st and 2nd Bx integral vs y at -1,0 and 1 mm. Motion is +/- 0.5 mm Test Currents for Main (A): 0.00 0.00 Bx 1st Field Integral vs XY Distance the wire was moved = 0.001000 m Number of turns in the wire = 1 Number of measurements for averaging = 6 Main +/- sigma X Y Integral sigIntegral (A) (m) (m) (Tm) -------------+--------- ----------- ----------- ------------+------------ 0.0000 0.0000 0.000000 -0.001000 0.000153 0.000008 0.0000 0.0000 0.000000 0.000000 0.000518 0.000012 0.0000 0.0000 0.000000 0.001000 0.000932 0.000014 0.0000 0.0000 0.000000 -0.001000 0.000143 0.000009 0.0000 0.0000 0.000000 0.000000 0.000520 0.000009 0.0000 0.0000 0.000000 0.001000 0.000932 0.000018