SLAC Magnetic Measurements Date: 09-24-2015 Time: 17:48:11 Project: SSRL Magnet Type: Undulator Magnet Name: BL13_ID Magnet Mode: CP Magnet Gap: 18.5 mm Magnet Phase: 0.175 Run Number: 1 Measurement Device: 10wire Operator: sda Comment: Bx integrals at -0.5, -0.175, 0, 0.175 and 0.5 phase. Gap = 18.5. Bx 2nd Field Integral Distance the wire was moved = 0.002000 m Number of turns in the wire = 10 Number of measurements for averaging = 4 Main +/- sigma X Y Integral sigIntegral (A) (m) (m) (Tm^2) -------------+--------- ----------- ----------- ------------+------------ 0.0000 0.0000 0.000000 0.000000 -0.000637 0.000028 0.0000 0.0000 0.000000 0.000000 -0.000630 0.000024 0.0000 0.0000 0.000000 0.000000 -0.000635 0.000011