SLAC Magnetic Measurements Date: 09-16-2002 Time: 15:41:11 Project: SSRL Magnet Type: Solenoid Magnet Name: GTFsolenoid_a Serial Number: Run Number: 7 Measurement Device: B9900 Hall probe Operator: zw Comment: Bz vs z at several currents on geometric axis, z=0 is magnet center Standardization: 4 cycles from 0.0 A to 220.0 A to 0.0 A Test Currents (A): 20.0 50.0 100.0 150.0 200.0 220.0 15:41:25 Stage Zeroed 15:41:25 MoveZ Devices: Move Device = SXDRIVE, Read Device = SXDRIVE 15:43:13 Hall Probe Zeroed 15:44:09 Hall Probe Type Being Used, type = B9900 15:44:11 Initial Zero Current Measurement, Imag_zero = 0.0000 A 15:44:11 Magnet current ramping to 25.0000 A... 15:45:16 Hall Probe Range Set, range = 5 15:45:16 Magnet current ramping to 220.0000 A... 15:46:50 Magnet current ramping to 0.0000 A... 15:48:39 Magnet current ramping to 220.0000 A... 15:50:26 Magnet current ramping to 0.0000 A... 15:52:57 Magnet current ramping to 220.0000 A... 15:54:39 Magnet current ramping to 0.0000 A... 15:56:25 Magnet current ramping to 220.0000 A... 15:58:10 Magnet current ramping to 0.0000 A... 15:59:51 Magnet current ramping to 220.0000 A... 16:01:36 Magnet current ramping to 0.0000 A... 16:03:25 Hall Probe Range Set, range = 4 16:03:26 Magnet current ramping to 20.0000 A... 16:04:59 Move Stage, position = -0.250000 16:05:00 Stage Position Measurement, pos = -0.250000 m 16:05:02 Magnet Current, Imag = 19.9162 A Vtrans = 0.199162 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:03 Hall Probe Field Measurement, B = 0.000010 T 16:05:11 Move Stage, position = -0.240000 16:05:12 Stage Position Measurement, pos = -0.240000 m 16:05:14 Magnet Current, Imag = 19.9128 A Vtrans = 0.199128 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:16 Hall Probe Field Measurement, B = 0.000000 T 16:05:24 Move Stage, position = -0.230000 16:05:25 Stage Position Measurement, pos = -0.230000 m 16:05:27 Magnet Current, Imag = 19.9127 A Vtrans = 0.199127 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:27 Hall Probe Field Measurement, B = -0.000010 T 16:05:35 Move Stage, position = -0.220000 16:05:36 Stage Position Measurement, pos = -0.220000 m 16:05:38 Magnet Current, Imag = 19.9255 A Vtrans = 0.199255 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:38 Hall Probe Field Measurement, B = -0.000030 T 16:05:46 Move Stage, position = -0.210000 16:05:47 Stage Position Measurement, pos = -0.210000 m 16:05:49 Magnet Current, Imag = 19.9126 A Vtrans = 0.199126 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:49 Hall Probe Field Measurement, B = -0.000070 T 16:05:57 Move Stage, position = -0.200000 16:05:58 Stage Position Measurement, pos = -0.200000 m 16:05:59 Magnet Current, Imag = 19.9276 A Vtrans = 0.199276 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:06:00 Hall Probe Field Measurement, B = -0.000100 T 16:06:08 Move Stage, position = -0.190000 16:06:09 Stage Position Measurement, pos = -0.190000 m 16:06:10 Magnet Current, Imag = 19.9175 A Vtrans = 0.199175 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:06:11 Hall Probe Field Measurement, B = -0.000170 T 16:06:19 Move Stage, position = -0.180000 16:06:20 Stage Position Measurement, pos = -0.180000 m 16:06:21 Magnet Current, Imag = 19.9204 A Vtrans = 0.199204 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:06:22 Hall Probe Field Measurement, B = -0.000270 T 16:06:29 Move Stage, position = -0.170000 16:06:30 Stage Position Measurement, pos = -0.170000 m 16:06:32 Magnet Current, Imag = 19.9083 A Vtrans = 0.199083 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:06:33 Hall Probe Field Measurement, B = -0.000440 T 16:06:40 Move Stage, position = -0.160000 16:06:41 Stage Position Measurement, pos = -0.160000 m 16:06:43 Magnet Current, Imag = 19.9189 A Vtrans = 0.199189 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:06:44 Hall Probe Field Measurement, B = -0.000750 T 16:06:51 Move Stage, position = -0.150000 16:06:52 Stage Position Measurement, pos = -0.150000 m 16:06:54 Magnet Current, Imag = 19.9146 A Vtrans = 0.199146 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:06:55 Hall Probe Field Measurement, B = -0.001280 T 16:07:02 Move Stage, position = -0.140000 16:07:03 Stage Position Measurement, pos = -0.140000 m 16:07:05 Magnet Current, Imag = 19.9023 A Vtrans = 0.199023 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:06 Hall Probe Field Measurement, B = -0.002280 T 16:07:13 Move Stage, position = -0.130000 16:07:14 Stage Position Measurement, pos = -0.130000 m 16:07:16 Magnet Current, Imag = 19.9222 A Vtrans = 0.199222 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:16 Hall Probe Field Measurement, B = -0.004030 T 16:07:24 Move Stage, position = -0.120000 16:07:25 Stage Position Measurement, pos = -0.120000 m 16:07:27 Magnet Current, Imag = 19.9128 A Vtrans = 0.199128 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:27 Hall Probe Field Measurement, B = -0.006970 T 16:07:35 Move Stage, position = -0.110000 16:07:36 Stage Position Measurement, pos = -0.110000 m 16:07:38 Magnet Current, Imag = 19.9183 A Vtrans = 0.199183 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:38 Hall Probe Field Measurement, B = -0.011200 T 16:07:46 Move Stage, position = -0.100000 16:07:47 Stage Position Measurement, pos = -0.100000 m 16:07:49 Magnet Current, Imag = 19.9187 A Vtrans = 0.199187 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:49 Hall Probe Field Measurement, B = -0.016180 T 16:07:57 Move Stage, position = -0.090000 16:07:58 Stage Position Measurement, pos = -0.090000 m 16:08:00 Magnet Current, Imag = 19.9141 A Vtrans = 0.199141 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:08:00 Hall Probe Field Measurement, B = -0.020780 T 16:08:08 Move Stage, position = -0.080000 16:08:09 Stage Position Measurement, pos = -0.080000 m 16:08:11 Magnet Current, Imag = 19.9179 A Vtrans = 0.199179 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:08:11 Hall Probe Field Measurement, B = -0.024260 T 16:08:19 Move Stage, position = -0.070000 16:08:20 Stage Position Measurement, pos = -0.070000 m 16:08:22 Magnet Current, Imag = 19.9151 A Vtrans = 0.199151 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:08:22 Hall Probe Field Measurement, B = -0.026590 T 16:08:30 Move Stage, position = -0.060000 16:08:31 Stage Position Measurement, pos = -0.060000 m 16:08:32 Magnet Current, Imag = 19.9026 A Vtrans = 0.199026 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:08:33 Hall Probe Field Measurement, B = -0.028010 T 16:08:41 Move Stage, position = -0.050000 16:08:42 Stage Position Measurement, pos = -0.050000 m 16:08:44 Magnet Current, Imag = 19.9209 A Vtrans = 0.199209 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:08:45 Hall Probe Field Measurement, B = -0.028870 T 16:08:53 Move Stage, position = -0.040000 16:08:54 Stage Position Measurement, pos = -0.040000 m 16:08:55 Magnet Current, Imag = 19.9199 A Vtrans = 0.199199 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:08:56 Hall Probe Field Measurement, B = -0.029360 T 16:09:03 Move Stage, position = -0.030000 16:09:05 Stage Position Measurement, pos = -0.030000 m 16:09:06 Magnet Current, Imag = 19.9104 A Vtrans = 0.199104 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:07 Hall Probe Field Measurement, B = -0.029630 T 16:09:14 Move Stage, position = -0.020000 16:09:15 Stage Position Measurement, pos = -0.020000 m 16:09:17 Magnet Current, Imag = 19.9162 A Vtrans = 0.199162 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:18 Hall Probe Field Measurement, B = -0.029780 T 16:09:25 Move Stage, position = -0.010000 16:09:26 Stage Position Measurement, pos = -0.010000 m 16:09:28 Magnet Current, Imag = 19.9106 A Vtrans = 0.199106 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:29 Hall Probe Field Measurement, B = -0.029820 T 16:09:37 Move Stage, position = 0.000000 16:09:38 Stage Position Measurement, pos = 0.000000 m 16:09:40 Magnet Current, Imag = 19.9102 A Vtrans = 0.199102 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:40 Hall Probe Field Measurement, B = -0.029830 T 16:09:48 Move Stage, position = 0.010000 16:09:49 Stage Position Measurement, pos = 0.010000 m 16:09:51 Magnet Current, Imag = 19.9045 A Vtrans = 0.199045 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:51 Hall Probe Field Measurement, B = -0.029770 T 16:09:59 Move Stage, position = 0.020000 16:10:00 Stage Position Measurement, pos = 0.020000 m 16:10:02 Magnet Current, Imag = 19.9039 A Vtrans = 0.199039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:10:02 Hall Probe Field Measurement, B = -0.029620 T 16:10:10 Move Stage, position = 0.030000 16:10:11 Stage Position Measurement, pos = 0.030000 m 16:10:13 Magnet Current, Imag = 19.9156 A Vtrans = 0.199156 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:10:13 Hall Probe Field Measurement, B = -0.029360 T 16:10:21 Move Stage, position = 0.040000 16:10:22 Stage Position Measurement, pos = 0.040000 m 16:10:23 Magnet Current, Imag = 19.9203 A Vtrans = 0.199203 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:10:24 Hall Probe Field Measurement, B = -0.028850 T 16:10:32 Move Stage, position = 0.050000 16:10:33 Stage Position Measurement, pos = 0.050000 m 16:10:34 Magnet Current, Imag = 19.9020 A Vtrans = 0.199020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:10:35 Hall Probe Field Measurement, B = -0.027940 T 16:10:43 Move Stage, position = 0.060000 16:10:44 Stage Position Measurement, pos = 0.060000 m 16:10:45 Magnet Current, Imag = 19.9054 A Vtrans = 0.199054 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:10:46 Hall Probe Field Measurement, B = -0.026420 T 16:10:53 Move Stage, position = 0.070000 16:10:55 Stage Position Measurement, pos = 0.070000 m 16:10:56 Magnet Current, Imag = 19.9078 A Vtrans = 0.199078 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:10:57 Hall Probe Field Measurement, B = -0.023960 T 16:11:04 Move Stage, position = 0.080000 16:11:05 Stage Position Measurement, pos = 0.080000 m 16:11:07 Magnet Current, Imag = 19.9125 A Vtrans = 0.199125 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:08 Hall Probe Field Measurement, B = -0.020330 T 16:11:15 Move Stage, position = 0.090000 16:11:16 Stage Position Measurement, pos = 0.090000 m 16:11:18 Magnet Current, Imag = 19.9066 A Vtrans = 0.199067 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:19 Hall Probe Field Measurement, B = -0.015600 T 16:11:26 Move Stage, position = 0.100000 16:11:27 Stage Position Measurement, pos = 0.100000 m 16:11:29 Magnet Current, Imag = 19.9079 A Vtrans = 0.199079 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:30 Hall Probe Field Measurement, B = -0.010660 T 16:11:37 Move Stage, position = 0.110000 16:11:38 Stage Position Measurement, pos = 0.110000 m 16:11:40 Magnet Current, Imag = 19.9050 A Vtrans = 0.199050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:41 Hall Probe Field Measurement, B = -0.006560 T 16:11:48 Move Stage, position = 0.120000 16:11:49 Stage Position Measurement, pos = 0.120000 m 16:11:51 Magnet Current, Imag = 19.9215 A Vtrans = 0.199215 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:52 Hall Probe Field Measurement, B = -0.003810 T 16:12:00 Move Stage, position = 0.130000 16:12:01 Stage Position Measurement, pos = 0.130000 m 16:12:03 Magnet Current, Imag = 19.9065 A Vtrans = 0.199065 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:12:03 Hall Probe Field Measurement, B = -0.002150 T 16:12:11 Move Stage, position = 0.140000 16:12:12 Stage Position Measurement, pos = 0.140000 m 16:12:14 Magnet Current, Imag = 19.9078 A Vtrans = 0.199078 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:12:14 Hall Probe Field Measurement, B = -0.001250 T 16:12:22 Move Stage, position = 0.150000 16:12:23 Stage Position Measurement, pos = 0.150000 m 16:12:25 Magnet Current, Imag = 19.9010 A Vtrans = 0.199010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:12:25 Hall Probe Field Measurement, B = -0.000740 T 16:12:33 Move Stage, position = 0.160000 16:12:34 Stage Position Measurement, pos = 0.160000 m 16:12:36 Magnet Current, Imag = 19.9080 A Vtrans = 0.199080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:12:36 Hall Probe Field Measurement, B = -0.000450 T 16:12:44 Move Stage, position = 0.170000 16:12:45 Stage Position Measurement, pos = 0.170000 m 16:12:47 Magnet Current, Imag = 19.9040 A Vtrans = 0.199040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:12:47 Hall Probe Field Measurement, B = -0.000290 T 16:12:55 Move Stage, position = 0.180000 16:12:56 Stage Position Measurement, pos = 0.180000 m 16:12:58 Magnet Current, Imag = 19.9085 A Vtrans = 0.199085 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:12:58 Hall Probe Field Measurement, B = -0.000190 T 16:13:06 Move Stage, position = 0.190000 16:13:07 Stage Position Measurement, pos = 0.190000 m 16:13:08 Magnet Current, Imag = 19.9030 A Vtrans = 0.199030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:09 Hall Probe Field Measurement, B = -0.000120 T 16:13:17 Move Stage, position = 0.200000 16:13:18 Stage Position Measurement, pos = 0.200000 m 16:13:20 Magnet Current, Imag = 19.9083 A Vtrans = 0.199083 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:21 Hall Probe Field Measurement, B = -0.000080 T 16:13:28 Move Stage, position = 0.210000 16:13:29 Stage Position Measurement, pos = 0.210000 m 16:13:31 Magnet Current, Imag = 19.8994 A Vtrans = 0.198994 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:32 Hall Probe Field Measurement, B = -0.000070 T 16:13:39 Move Stage, position = 0.220000 16:13:40 Stage Position Measurement, pos = 0.220000 m 16:13:42 Magnet Current, Imag = 19.8986 A Vtrans = 0.198986 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:43 Hall Probe Field Measurement, B = -0.000040 T 16:13:50 Move Stage, position = 0.230000 16:13:51 Stage Position Measurement, pos = 0.230000 m 16:13:53 Magnet Current, Imag = 19.9047 A Vtrans = 0.199047 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:54 Hall Probe Field Measurement, B = -0.000040 T 16:14:01 Move Stage, position = 0.240000 16:14:02 Stage Position Measurement, pos = 0.240000 m 16:14:04 Magnet Current, Imag = 19.8975 A Vtrans = 0.198975 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:14:04 Hall Probe Field Measurement, B = -0.000010 T 16:14:12 Move Stage, position = 0.250000 16:14:13 Stage Position Measurement, pos = 0.250000 m 16:14:15 Magnet Current, Imag = 19.9033 A Vtrans = 0.199033 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:14:15 Hall Probe Field Measurement, B = -0.000010 T 16:15:11 Move Stage, position = 0.000000 16:15:15 Hall Probe Range Set, range = 4 16:15:15 Magnet current ramping to 50.0000 A... 16:16:51 Move Stage, position = -0.250000 16:16:52 Stage Position Measurement, pos = -0.250000 m 16:16:53 Magnet Current, Imag = 49.9221 A Vtrans = 0.499221 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:16:54 Hall Probe Field Measurement, B = -0.000170 T 16:17:01 Move Stage, position = -0.240000 16:17:02 Stage Position Measurement, pos = -0.240000 m 16:17:04 Magnet Current, Imag = 49.9218 A Vtrans = 0.499218 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:04 Hall Probe Field Measurement, B = -0.000200 T 16:17:12 Move Stage, position = -0.230000 16:17:13 Stage Position Measurement, pos = -0.230000 m 16:17:14 Magnet Current, Imag = 49.9214 A Vtrans = 0.499214 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:15 Hall Probe Field Measurement, B = -0.000240 T 16:17:22 Move Stage, position = -0.220000 16:17:23 Stage Position Measurement, pos = -0.220000 m 16:17:25 Magnet Current, Imag = 49.9239 A Vtrans = 0.499239 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:25 Hall Probe Field Measurement, B = -0.000300 T 16:17:33 Move Stage, position = -0.210000 16:17:34 Stage Position Measurement, pos = -0.210000 m 16:17:35 Magnet Current, Imag = 49.9286 A Vtrans = 0.499286 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:36 Hall Probe Field Measurement, B = -0.000390 T 16:17:43 Move Stage, position = -0.200000 16:17:44 Stage Position Measurement, pos = -0.200000 m 16:17:46 Magnet Current, Imag = 49.9234 A Vtrans = 0.499234 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:46 Hall Probe Field Measurement, B = -0.000510 T 16:17:54 Move Stage, position = -0.190000 16:17:55 Stage Position Measurement, pos = -0.190000 m 16:17:56 Magnet Current, Imag = 49.9207 A Vtrans = 0.499207 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:57 Hall Probe Field Measurement, B = -0.000690 T 16:18:04 Move Stage, position = -0.180000 16:18:05 Stage Position Measurement, pos = -0.180000 m 16:18:07 Magnet Current, Imag = 49.9225 A Vtrans = 0.499225 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:18:07 Hall Probe Field Measurement, B = -0.000980 T 16:18:15 Move Stage, position = -0.170000 16:18:16 Stage Position Measurement, pos = -0.170000 m 16:18:17 Magnet Current, Imag = 49.9220 A Vtrans = 0.499220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:18:18 Hall Probe Field Measurement, B = -0.001430 T 16:18:25 Move Stage, position = -0.160000 16:18:26 Stage Position Measurement, pos = -0.160000 m 16:18:28 Magnet Current, Imag = 49.9140 A Vtrans = 0.499140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:18:28 Hall Probe Field Measurement, B = -0.002200 T 16:18:36 Move Stage, position = -0.150000 16:18:37 Stage Position Measurement, pos = -0.150000 m 16:18:38 Magnet Current, Imag = 49.9142 A Vtrans = 0.499142 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:18:41 Hall Probe Field Measurement, B = -0.003560 T 16:18:48 Move Stage, position = -0.140000 16:18:49 Stage Position Measurement, pos = -0.140000 m 16:18:51 Magnet Current, Imag = 49.9145 A Vtrans = 0.499145 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:18:51 Hall Probe Field Measurement, B = -0.005990 T 16:18:59 Move Stage, position = -0.130000 16:19:00 Stage Position Measurement, pos = -0.130000 m 16:19:01 Magnet Current, Imag = 49.9182 A Vtrans = 0.499182 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:02 Hall Probe Field Measurement, B = -0.010280 T 16:19:09 Move Stage, position = -0.120000 16:19:10 Stage Position Measurement, pos = -0.120000 m 16:19:12 Magnet Current, Imag = 49.9270 A Vtrans = 0.499270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:12 Hall Probe Field Measurement, B = -0.017480 T 16:19:20 Move Stage, position = -0.110000 16:19:21 Stage Position Measurement, pos = -0.110000 m 16:19:22 Magnet Current, Imag = 49.9236 A Vtrans = 0.499236 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:23 Hall Probe Field Measurement, B = -0.027840 T 16:19:30 Move Stage, position = -0.100000 16:19:31 Stage Position Measurement, pos = -0.100000 m 16:19:33 Magnet Current, Imag = 49.9195 A Vtrans = 0.499195 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:33 Hall Probe Field Measurement, B = -0.040060 T 16:19:41 Move Stage, position = -0.090000 16:19:42 Stage Position Measurement, pos = -0.090000 m 16:19:43 Magnet Current, Imag = 49.9142 A Vtrans = 0.499142 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:44 Hall Probe Field Measurement, B = -0.051440 T 16:19:51 Move Stage, position = -0.080000 16:19:52 Stage Position Measurement, pos = -0.080000 m 16:19:53 Magnet Current, Imag = 49.9180 A Vtrans = 0.499180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:54 Hall Probe Field Measurement, B = -0.060040 T 16:20:02 Move Stage, position = -0.070000 16:20:03 Stage Position Measurement, pos = -0.070000 m 16:20:04 Magnet Current, Imag = 49.9114 A Vtrans = 0.499114 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:20:05 Hall Probe Field Measurement, B = -0.065820 T 16:20:12 Move Stage, position = -0.060000 16:20:13 Stage Position Measurement, pos = -0.060000 m 16:20:14 Magnet Current, Imag = 49.9223 A Vtrans = 0.499223 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:20:16 Hall Probe Field Measurement, B = -0.069400 T 16:20:24 Move Stage, position = -0.050000 16:20:25 Stage Position Measurement, pos = -0.050000 m 16:20:26 Magnet Current, Imag = 49.9130 A Vtrans = 0.499130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:20:26 Hall Probe Field Measurement, B = -0.071550 T 16:20:34 Move Stage, position = -0.040000 16:20:35 Stage Position Measurement, pos = -0.040000 m 16:20:36 Magnet Current, Imag = 49.9213 A Vtrans = 0.499213 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:20:37 Hall Probe Field Measurement, B = -0.072790 T 16:20:45 Move Stage, position = -0.030000 16:20:46 Stage Position Measurement, pos = -0.030000 m 16:20:47 Magnet Current, Imag = 49.9105 A Vtrans = 0.499105 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:20:47 Hall Probe Field Measurement, B = -0.073480 T 16:20:55 Move Stage, position = -0.020000 16:20:56 Stage Position Measurement, pos = -0.020000 m 16:20:57 Magnet Current, Imag = 49.9194 A Vtrans = 0.499194 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:20:58 Hall Probe Field Measurement, B = -0.073870 T 16:21:05 Move Stage, position = -0.010000 16:21:07 Stage Position Measurement, pos = -0.010000 m 16:21:08 Magnet Current, Imag = 49.9149 A Vtrans = 0.499149 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:21:08 Hall Probe Field Measurement, B = -0.074030 T 16:21:16 Move Stage, position = 0.000000 16:21:17 Stage Position Measurement, pos = 0.000000 m 16:21:18 Magnet Current, Imag = 49.9122 A Vtrans = 0.499122 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:21:19 Hall Probe Field Measurement, B = -0.074030 T 16:21:26 Move Stage, position = 0.010000 16:21:27 Stage Position Measurement, pos = 0.010000 m 16:21:29 Magnet Current, Imag = 49.9166 A Vtrans = 0.499166 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:21:29 Hall Probe Field Measurement, B = -0.073860 T 16:21:37 Move Stage, position = 0.020000 16:21:38 Stage Position Measurement, pos = 0.020000 m 16:21:39 Magnet Current, Imag = 49.9223 A Vtrans = 0.499223 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:21:40 Hall Probe Field Measurement, B = -0.073500 T 16:21:47 Move Stage, position = 0.030000 16:21:48 Stage Position Measurement, pos = 0.030000 m 16:21:50 Magnet Current, Imag = 49.9285 A Vtrans = 0.499285 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:21:50 Hall Probe Field Measurement, B = -0.072780 T 16:21:58 Move Stage, position = 0.040000 16:21:59 Stage Position Measurement, pos = 0.040000 m 16:22:00 Magnet Current, Imag = 49.9115 A Vtrans = 0.499115 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:22:01 Hall Probe Field Measurement, B = -0.071450 T 16:22:08 Move Stage, position = 0.050000 16:22:09 Stage Position Measurement, pos = 0.050000 m 16:22:11 Magnet Current, Imag = 49.9196 A Vtrans = 0.499196 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:22:12 Hall Probe Field Measurement, B = -0.069210 T 16:22:20 Move Stage, position = 0.060000 16:22:21 Stage Position Measurement, pos = 0.060000 m 16:22:22 Magnet Current, Imag = 49.9199 A Vtrans = 0.499199 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:22:23 Hall Probe Field Measurement, B = -0.065430 T 16:22:30 Move Stage, position = 0.070000 16:22:31 Stage Position Measurement, pos = 0.070000 m 16:22:33 Magnet Current, Imag = 49.9249 A Vtrans = 0.499249 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:22:34 Hall Probe Field Measurement, B = -0.059320 T 16:22:41 Move Stage, position = 0.080000 16:22:42 Stage Position Measurement, pos = 0.080000 m 16:22:44 Magnet Current, Imag = 49.9045 A Vtrans = 0.499045 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:22:44 Hall Probe Field Measurement, B = -0.050300 T 16:22:52 Move Stage, position = 0.090000 16:22:53 Stage Position Measurement, pos = 0.090000 m 16:22:54 Magnet Current, Imag = 49.9117 A Vtrans = 0.499117 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:22:55 Hall Probe Field Measurement, B = -0.038670 T 16:23:02 Move Stage, position = 0.100000 16:23:03 Stage Position Measurement, pos = 0.100000 m 16:23:05 Magnet Current, Imag = 49.9091 A Vtrans = 0.499091 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:23:05 Hall Probe Field Measurement, B = -0.026550 T 16:23:13 Move Stage, position = 0.110000 16:23:14 Stage Position Measurement, pos = 0.110000 m 16:23:15 Magnet Current, Imag = 49.9155 A Vtrans = 0.499155 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:23:16 Hall Probe Field Measurement, B = -0.016490 T 16:23:23 Move Stage, position = 0.120000 16:23:24 Stage Position Measurement, pos = 0.120000 m 16:23:26 Magnet Current, Imag = 49.9123 A Vtrans = 0.499123 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:23:26 Hall Probe Field Measurement, B = -0.009730 T 16:23:34 Move Stage, position = 0.130000 16:23:35 Stage Position Measurement, pos = 0.130000 m 16:23:36 Magnet Current, Imag = 49.9215 A Vtrans = 0.499215 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:23:37 Hall Probe Field Measurement, B = -0.005680 T 16:23:44 Move Stage, position = 0.140000 16:23:45 Stage Position Measurement, pos = 0.140000 m 16:23:47 Magnet Current, Imag = 49.9145 A Vtrans = 0.499145 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:23:47 Hall Probe Field Measurement, B = -0.003430 T 16:23:55 Move Stage, position = 0.150000 16:23:56 Stage Position Measurement, pos = 0.150000 m 16:23:57 Magnet Current, Imag = 49.9177 A Vtrans = 0.499177 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:23:58 Hall Probe Field Measurement, B = -0.002160 T 16:24:05 Move Stage, position = 0.160000 16:24:06 Stage Position Measurement, pos = 0.160000 m 16:24:08 Magnet Current, Imag = 49.9192 A Vtrans = 0.499192 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:24:08 Hall Probe Field Measurement, B = -0.001430 T 16:24:16 Move Stage, position = 0.170000 16:24:17 Stage Position Measurement, pos = 0.170000 m 16:24:18 Magnet Current, Imag = 49.9061 A Vtrans = 0.499061 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:24:19 Hall Probe Field Measurement, B = -0.001010 T 16:24:26 Move Stage, position = 0.180000 16:24:27 Stage Position Measurement, pos = 0.180000 m 16:24:29 Magnet Current, Imag = 49.9138 A Vtrans = 0.499138 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:24:29 Hall Probe Field Measurement, B = -0.000720 T 16:24:37 Move Stage, position = 0.190000 16:24:38 Stage Position Measurement, pos = 0.190000 m 16:24:39 Magnet Current, Imag = 49.9178 A Vtrans = 0.499178 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:24:40 Hall Probe Field Measurement, B = -0.000550 T 16:24:47 Move Stage, position = 0.200000 16:24:48 Stage Position Measurement, pos = 0.200000 m 16:24:49 Magnet Current, Imag = 49.9156 A Vtrans = 0.499156 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:24:51 Hall Probe Field Measurement, B = -0.000430 T 16:24:59 Move Stage, position = 0.210000 16:25:00 Stage Position Measurement, pos = 0.210000 m 16:25:01 Magnet Current, Imag = 49.9142 A Vtrans = 0.499142 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:25:02 Hall Probe Field Measurement, B = -0.000360 T 16:25:09 Move Stage, position = 0.220000 16:25:10 Stage Position Measurement, pos = 0.220000 m 16:25:12 Magnet Current, Imag = 49.9166 A Vtrans = 0.499166 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:25:12 Hall Probe Field Measurement, B = -0.000290 T 16:25:20 Move Stage, position = 0.230000 16:25:21 Stage Position Measurement, pos = 0.230000 m 16:25:22 Magnet Current, Imag = 49.9163 A Vtrans = 0.499163 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:25:23 Hall Probe Field Measurement, B = -0.000250 T 16:25:30 Move Stage, position = 0.240000 16:25:31 Stage Position Measurement, pos = 0.240000 m 16:25:33 Magnet Current, Imag = 49.9129 A Vtrans = 0.499129 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:25:33 Hall Probe Field Measurement, B = -0.000220 T 16:25:41 Move Stage, position = 0.250000 16:25:42 Stage Position Measurement, pos = 0.250000 m 16:25:43 Magnet Current, Imag = 49.9210 A Vtrans = 0.499210 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:25:44 Hall Probe Field Measurement, B = -0.000190 T 16:26:39 Move Stage, position = 0.000000 16:26:43 Hall Probe Range Set, range = 4 16:26:43 Magnet current ramping to 100.0000 A... 16:28:25 Move Stage, position = -0.250000 16:28:26 Stage Position Measurement, pos = -0.250000 m 16:28:27 Magnet Current, Imag = 99.9492 A Vtrans = 0.999492 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:28:28 Hall Probe Field Measurement, B = -0.000340 T 16:28:35 Move Stage, position = -0.240000 16:28:36 Stage Position Measurement, pos = -0.240000 m 16:28:38 Magnet Current, Imag = 99.9534 A Vtrans = 0.999534 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:28:38 Hall Probe Field Measurement, B = -0.000400 T 16:28:46 Move Stage, position = -0.230000 16:28:47 Stage Position Measurement, pos = -0.230000 m 16:28:48 Magnet Current, Imag = 99.9583 A Vtrans = 0.999583 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:28:49 Hall Probe Field Measurement, B = -0.000490 T 16:28:56 Move Stage, position = -0.220000 16:28:57 Stage Position Measurement, pos = -0.220000 m 16:28:59 Magnet Current, Imag = 99.9533 A Vtrans = 0.999533 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:28:59 Hall Probe Field Measurement, B = -0.000610 T 16:29:07 Move Stage, position = -0.210000 16:29:08 Stage Position Measurement, pos = -0.210000 m 16:29:09 Magnet Current, Imag = 99.9621 A Vtrans = 0.999621 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:29:10 Hall Probe Field Measurement, B = -0.000790 T 16:29:17 Move Stage, position = -0.200000 16:29:18 Stage Position Measurement, pos = -0.200000 m 16:29:20 Magnet Current, Imag = 99.9535 A Vtrans = 0.999535 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:29:20 Hall Probe Field Measurement, B = -0.001020 T 16:29:28 Move Stage, position = -0.190000 16:29:29 Stage Position Measurement, pos = -0.190000 m 16:29:30 Magnet Current, Imag = 99.9592 A Vtrans = 0.999592 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:29:31 Hall Probe Field Measurement, B = -0.001390 T 16:29:38 Move Stage, position = -0.180000 16:29:39 Stage Position Measurement, pos = -0.180000 m 16:29:41 Magnet Current, Imag = 99.9572 A Vtrans = 0.999572 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:29:41 Hall Probe Field Measurement, B = -0.001970 T 16:29:49 Move Stage, position = -0.170000 16:29:50 Stage Position Measurement, pos = -0.170000 m 16:29:51 Magnet Current, Imag = 99.9613 A Vtrans = 0.999613 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:29:52 Hall Probe Field Measurement, B = -0.002890 T 16:29:59 Move Stage, position = -0.160000 16:30:00 Stage Position Measurement, pos = -0.160000 m 16:30:02 Magnet Current, Imag = 99.9517 A Vtrans = 0.999517 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:30:02 Hall Probe Field Measurement, B = -0.004430 T 16:30:10 Move Stage, position = -0.150000 16:30:11 Stage Position Measurement, pos = -0.150000 m 16:30:12 Magnet Current, Imag = 99.9508 A Vtrans = 0.999508 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:30:13 Hall Probe Field Measurement, B = -0.007130 T 16:30:20 Move Stage, position = -0.140000 16:30:21 Stage Position Measurement, pos = -0.140000 m 16:30:23 Magnet Current, Imag = 99.9451 A Vtrans = 0.999451 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:30:23 Hall Probe Field Measurement, B = -0.012000 T 16:30:31 Move Stage, position = -0.130000 16:30:32 Stage Position Measurement, pos = -0.130000 m 16:30:33 Magnet Current, Imag = 99.9465 A Vtrans = 0.999465 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:30:34 Hall Probe Field Measurement, B = -0.020590 T 16:30:41 Move Stage, position = -0.120000 16:30:42 Stage Position Measurement, pos = -0.120000 m 16:30:43 Magnet Current, Imag = 99.9548 A Vtrans = 0.999548 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:30:44 Hall Probe Field Measurement, B = -0.034990 T 16:30:52 Move Stage, position = -0.110000 16:30:53 Stage Position Measurement, pos = -0.110000 m 16:30:54 Magnet Current, Imag = 99.9471 A Vtrans = 0.999471 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:30:54 Hall Probe Field Measurement, B = -0.055700 T 16:31:02 Move Stage, position = -0.100000 16:31:03 Stage Position Measurement, pos = -0.100000 m 16:31:04 Magnet Current, Imag = 99.9549 A Vtrans = 0.999549 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:31:05 Hall Probe Field Measurement, B = -0.080160 T 16:31:13 Move Stage, position = -0.090000 16:31:14 Stage Position Measurement, pos = -0.090000 m 16:31:15 Magnet Current, Imag = 99.9512 A Vtrans = 0.999512 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:31:15 Hall Probe Field Measurement, B = -0.102900 T 16:31:22 Move Stage, position = -0.080000 16:31:23 Stage Position Measurement, pos = -0.080000 m 16:31:24 Magnet Current, Imag = 99.9469 A Vtrans = 0.999469 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:31:25 Hall Probe Field Measurement, B = -0.120090 T 16:31:32 Move Stage, position = -0.070000 16:31:33 Stage Position Measurement, pos = -0.070000 m 16:31:35 Magnet Current, Imag = 99.9453 A Vtrans = 0.999453 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:31:35 Hall Probe Field Measurement, B = -0.131680 T 16:31:43 Move Stage, position = -0.060000 16:31:44 Stage Position Measurement, pos = -0.060000 m 16:31:45 Magnet Current, Imag = 99.9569 A Vtrans = 0.999569 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:31:46 Hall Probe Field Measurement, B = -0.138860 T 16:31:53 Move Stage, position = -0.050000 16:31:54 Stage Position Measurement, pos = -0.050000 m 16:31:56 Magnet Current, Imag = 99.9572 A Vtrans = 0.999572 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:31:56 Hall Probe Field Measurement, B = -0.143160 T 16:32:04 Move Stage, position = -0.040000 16:32:05 Stage Position Measurement, pos = -0.040000 m 16:32:06 Magnet Current, Imag = 99.9506 A Vtrans = 0.999506 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:32:06 Hall Probe Field Measurement, B = -0.145650 T 16:32:14 Move Stage, position = -0.030000 16:32:15 Stage Position Measurement, pos = -0.030000 m 16:32:16 Magnet Current, Imag = 99.9527 A Vtrans = 0.999527 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:32:17 Hall Probe Field Measurement, B = -0.147050 T 16:32:25 Move Stage, position = -0.020000 16:32:26 Stage Position Measurement, pos = -0.020000 m 16:32:27 Magnet Current, Imag = 99.9526 A Vtrans = 0.999526 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:32:27 Hall Probe Field Measurement, B = -0.147820 T 16:32:35 Move Stage, position = -0.010000 16:32:36 Stage Position Measurement, pos = -0.010000 m 16:32:37 Magnet Current, Imag = 99.9506 A Vtrans = 0.999506 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:32:38 Hall Probe Field Measurement, B = -0.148130 T 16:32:46 Move Stage, position = 0.000000 16:32:47 Stage Position Measurement, pos = 0.000000 m 16:32:48 Magnet Current, Imag = 99.9466 A Vtrans = 0.999466 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:32:48 Hall Probe Field Measurement, B = -0.148130 T 16:32:56 Move Stage, position = 0.010000 16:32:57 Stage Position Measurement, pos = 0.010000 m 16:32:58 Magnet Current, Imag = 99.9447 A Vtrans = 0.999447 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:32:59 Hall Probe Field Measurement, B = -0.147790 T 16:33:07 Move Stage, position = 0.020000 16:33:08 Stage Position Measurement, pos = 0.020000 m 16:33:09 Magnet Current, Imag = 99.9545 A Vtrans = 0.999545 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:09 Hall Probe Field Measurement, B = -0.147050 T 16:33:17 Move Stage, position = 0.030000 16:33:18 Stage Position Measurement, pos = 0.030000 m 16:33:19 Magnet Current, Imag = 99.9404 A Vtrans = 0.999404 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:20 Hall Probe Field Measurement, B = -0.145610 T 16:33:27 Move Stage, position = 0.040000 16:33:29 Stage Position Measurement, pos = 0.040000 m 16:33:30 Magnet Current, Imag = 99.9388 A Vtrans = 0.999388 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:30 Hall Probe Field Measurement, B = -0.142970 T 16:33:38 Move Stage, position = 0.050000 16:33:39 Stage Position Measurement, pos = 0.050000 m 16:33:40 Magnet Current, Imag = 99.9499 A Vtrans = 0.999499 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:41 Hall Probe Field Measurement, B = -0.138490 T 16:33:48 Move Stage, position = 0.060000 16:33:49 Stage Position Measurement, pos = 0.060000 m 16:33:51 Magnet Current, Imag = 99.9515 A Vtrans = 0.999515 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:51 Hall Probe Field Measurement, B = -0.130870 T 16:33:59 Move Stage, position = 0.070000 16:34:00 Stage Position Measurement, pos = 0.070000 m 16:34:01 Magnet Current, Imag = 99.9461 A Vtrans = 0.999461 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:34:02 Hall Probe Field Measurement, B = -0.118650 T 16:34:09 Move Stage, position = 0.080000 16:34:10 Stage Position Measurement, pos = 0.080000 m 16:34:12 Magnet Current, Imag = 99.9429 A Vtrans = 0.999429 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:34:12 Hall Probe Field Measurement, B = -0.100630 T 16:34:20 Move Stage, position = 0.090000 16:34:21 Stage Position Measurement, pos = 0.090000 m 16:34:22 Magnet Current, Imag = 99.9531 A Vtrans = 0.999531 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:34:23 Hall Probe Field Measurement, B = -0.077340 T 16:34:30 Move Stage, position = 0.100000 16:34:31 Stage Position Measurement, pos = 0.100000 m 16:34:33 Magnet Current, Imag = 99.9542 A Vtrans = 0.999542 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:34:33 Hall Probe Field Measurement, B = -0.053100 T 16:34:41 Move Stage, position = 0.110000 16:34:42 Stage Position Measurement, pos = 0.110000 m 16:34:43 Magnet Current, Imag = 99.9545 A Vtrans = 0.999545 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:34:44 Hall Probe Field Measurement, B = -0.032980 T 16:34:51 Move Stage, position = 0.120000 16:34:52 Stage Position Measurement, pos = 0.120000 m 16:34:54 Magnet Current, Imag = 99.9503 A Vtrans = 0.999503 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:34:54 Hall Probe Field Measurement, B = -0.019480 T 16:35:02 Move Stage, position = 0.130000 16:35:03 Stage Position Measurement, pos = 0.130000 m 16:35:04 Magnet Current, Imag = 99.9535 A Vtrans = 0.999535 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:05 Hall Probe Field Measurement, B = -0.011370 T 16:35:12 Move Stage, position = 0.140000 16:35:13 Stage Position Measurement, pos = 0.140000 m 16:35:15 Magnet Current, Imag = 99.9405 A Vtrans = 0.999405 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:15 Hall Probe Field Measurement, B = -0.006870 T 16:35:23 Move Stage, position = 0.150000 16:35:24 Stage Position Measurement, pos = 0.150000 m 16:35:25 Magnet Current, Imag = 99.9545 A Vtrans = 0.999545 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:26 Hall Probe Field Measurement, B = -0.004330 T 16:35:33 Move Stage, position = 0.160000 16:35:34 Stage Position Measurement, pos = 0.160000 m 16:35:36 Magnet Current, Imag = 99.9433 A Vtrans = 0.999433 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:36 Hall Probe Field Measurement, B = -0.002870 T 16:35:44 Move Stage, position = 0.170000 16:35:45 Stage Position Measurement, pos = 0.170000 m 16:35:46 Magnet Current, Imag = 99.9455 A Vtrans = 0.999455 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:47 Hall Probe Field Measurement, B = -0.002000 T 16:35:54 Move Stage, position = 0.180000 16:35:55 Stage Position Measurement, pos = 0.180000 m 16:35:56 Magnet Current, Imag = 99.9564 A Vtrans = 0.999564 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:57 Hall Probe Field Measurement, B = -0.001460 T 16:36:05 Move Stage, position = 0.190000 16:36:06 Stage Position Measurement, pos = 0.190000 m 16:36:07 Magnet Current, Imag = 99.9490 A Vtrans = 0.999490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:36:08 Hall Probe Field Measurement, B = -0.001110 T 16:36:15 Move Stage, position = 0.200000 16:36:16 Stage Position Measurement, pos = 0.200000 m 16:36:17 Magnet Current, Imag = 99.9591 A Vtrans = 0.999591 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:36:19 Hall Probe Field Measurement, B = -0.000860 T 16:36:25 Move Stage, position = 0.210000 16:36:26 Stage Position Measurement, pos = 0.210000 m 16:36:27 Magnet Current, Imag = 99.9407 A Vtrans = 0.999407 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:36:28 Hall Probe Field Measurement, B = -0.000700 T 16:36:35 Move Stage, position = 0.220000 16:36:37 Stage Position Measurement, pos = 0.220000 m 16:36:38 Magnet Current, Imag = 99.9520 A Vtrans = 0.999520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:36:38 Hall Probe Field Measurement, B = -0.000580 T 16:36:46 Move Stage, position = 0.230000 16:36:47 Stage Position Measurement, pos = 0.230000 m 16:36:48 Magnet Current, Imag = 99.9470 A Vtrans = 0.999470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:36:49 Hall Probe Field Measurement, B = -0.000490 T 16:36:56 Move Stage, position = 0.240000 16:36:57 Stage Position Measurement, pos = 0.240000 m 16:36:59 Magnet Current, Imag = 99.9393 A Vtrans = 0.999393 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:36:59 Hall Probe Field Measurement, B = -0.000410 T 16:37:07 Move Stage, position = 0.250000 16:37:08 Stage Position Measurement, pos = 0.250000 m 16:37:09 Magnet Current, Imag = 99.9494 A Vtrans = 0.999494 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:37:10 Hall Probe Field Measurement, B = -0.000360 T 16:38:04 Move Stage, position = 0.000000 16:38:08 Hall Probe Range Set, range = 4 16:38:08 Magnet current ramping to 150.0000 A... 16:39:49 Move Stage, position = -0.250000 16:39:50 Stage Position Measurement, pos = -0.250000 m 16:39:52 Magnet Current, Imag = 149.9734 A Vtrans = 1.499734 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:39:53 Hall Probe Field Measurement, B = -0.000510 T 16:40:00 Move Stage, position = -0.240000 16:40:01 Stage Position Measurement, pos = -0.240000 m 16:40:03 Magnet Current, Imag = 149.9748 A Vtrans = 1.499748 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:40:03 Hall Probe Field Measurement, B = -0.000610 T 16:40:11 Move Stage, position = -0.230000 16:40:12 Stage Position Measurement, pos = -0.230000 m 16:40:13 Magnet Current, Imag = 149.9772 A Vtrans = 1.499772 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:40:14 Hall Probe Field Measurement, B = -0.000750 T 16:40:21 Move Stage, position = -0.220000 16:40:22 Stage Position Measurement, pos = -0.220000 m 16:40:24 Magnet Current, Imag = 149.9685 A Vtrans = 1.499685 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:40:24 Hall Probe Field Measurement, B = -0.000930 T 16:40:32 Move Stage, position = -0.210000 16:40:33 Stage Position Measurement, pos = -0.210000 m 16:40:34 Magnet Current, Imag = 149.9852 A Vtrans = 1.499852 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:40:35 Hall Probe Field Measurement, B = -0.001180 T 16:40:42 Move Stage, position = -0.200000 16:40:43 Stage Position Measurement, pos = -0.200000 m 16:40:45 Magnet Current, Imag = 149.9758 A Vtrans = 1.499758 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:40:45 Hall Probe Field Measurement, B = -0.001560 T 16:40:53 Move Stage, position = -0.190000 16:40:54 Stage Position Measurement, pos = -0.190000 m 16:40:55 Magnet Current, Imag = 149.9727 A Vtrans = 1.499727 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:40:56 Hall Probe Field Measurement, B = -0.002100 T 16:41:03 Move Stage, position = -0.180000 16:41:04 Stage Position Measurement, pos = -0.180000 m 16:41:06 Magnet Current, Imag = 149.9813 A Vtrans = 1.499813 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:41:07 Hall Probe Field Measurement, B = -0.002960 T 16:41:14 Move Stage, position = -0.170000 16:41:15 Stage Position Measurement, pos = -0.170000 m 16:41:17 Magnet Current, Imag = 149.9856 A Vtrans = 1.499856 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:41:17 Hall Probe Field Measurement, B = -0.004340 T 16:41:25 Move Stage, position = -0.160000 16:41:26 Stage Position Measurement, pos = -0.160000 m 16:41:27 Magnet Current, Imag = 149.9653 A Vtrans = 1.499653 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:41:28 Hall Probe Field Measurement, B = -0.006660 T 16:41:35 Move Stage, position = -0.150000 16:41:36 Stage Position Measurement, pos = -0.150000 m 16:41:38 Magnet Current, Imag = 149.9754 A Vtrans = 1.499754 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:41:38 Hall Probe Field Measurement, B = -0.010710 T 16:41:46 Move Stage, position = -0.140000 16:41:47 Stage Position Measurement, pos = -0.140000 m 16:41:48 Magnet Current, Imag = 149.9703 A Vtrans = 1.499703 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:41:49 Hall Probe Field Measurement, B = -0.018010 T 16:41:56 Move Stage, position = -0.130000 16:41:57 Stage Position Measurement, pos = -0.130000 m 16:41:59 Magnet Current, Imag = 149.9762 A Vtrans = 1.499762 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:41:59 Hall Probe Field Measurement, B = -0.030900 T 16:42:07 Move Stage, position = -0.120000 16:42:08 Stage Position Measurement, pos = -0.120000 m 16:42:09 Magnet Current, Imag = 149.9710 A Vtrans = 1.499710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:42:10 Hall Probe Field Measurement, B = -0.052500 T 16:42:17 Move Stage, position = -0.110000 16:42:18 Stage Position Measurement, pos = -0.110000 m 16:42:19 Magnet Current, Imag = 149.9742 A Vtrans = 1.499742 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:42:20 Hall Probe Field Measurement, B = -0.083550 T 16:42:28 Move Stage, position = -0.100000 16:42:29 Stage Position Measurement, pos = -0.100000 m 16:42:30 Magnet Current, Imag = 149.9760 A Vtrans = 1.499760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:42:30 Hall Probe Field Measurement, B = -0.120190 T 16:42:38 Move Stage, position = -0.090000 16:42:39 Stage Position Measurement, pos = -0.090000 m 16:42:40 Magnet Current, Imag = 149.9713 A Vtrans = 1.499713 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:42:41 Hall Probe Field Measurement, B = -0.154290 T 16:42:49 Move Stage, position = -0.080000 16:42:50 Stage Position Measurement, pos = -0.080000 m 16:42:51 Magnet Current, Imag = 149.9859 A Vtrans = 1.499859 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:42:51 Hall Probe Field Measurement, B = -0.180090 T 16:42:59 Move Stage, position = -0.070000 16:43:00 Stage Position Measurement, pos = -0.070000 m 16:43:01 Magnet Current, Imag = 149.9735 A Vtrans = 1.499735 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:43:02 Hall Probe Field Measurement, B = -0.197470 T 16:43:09 Move Stage, position = -0.060000 16:43:11 Stage Position Measurement, pos = -0.060000 m 16:43:12 Magnet Current, Imag = 149.9753 A Vtrans = 1.499753 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:43:12 Hall Probe Field Measurement, B = -0.208210 T 16:43:20 Move Stage, position = -0.050000 16:43:21 Stage Position Measurement, pos = -0.050000 m 16:43:22 Magnet Current, Imag = 149.9791 A Vtrans = 1.499791 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:43:23 Hall Probe Field Measurement, B = -0.214670 T 16:43:30 Move Stage, position = -0.040000 16:43:32 Stage Position Measurement, pos = -0.040000 m 16:43:33 Magnet Current, Imag = 149.9658 A Vtrans = 1.499658 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:43:33 Hall Probe Field Measurement, B = -0.218380 T 16:43:41 Move Stage, position = -0.030000 16:43:42 Stage Position Measurement, pos = -0.030000 m 16:43:43 Magnet Current, Imag = 149.9825 A Vtrans = 1.499825 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:43:44 Hall Probe Field Measurement, B = -0.220520 T 16:43:51 Move Stage, position = -0.020000 16:43:52 Stage Position Measurement, pos = -0.020000 m 16:43:54 Magnet Current, Imag = 149.9735 A Vtrans = 1.499735 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:43:54 Hall Probe Field Measurement, B = -0.221640 T 16:44:02 Move Stage, position = -0.010000 16:44:03 Stage Position Measurement, pos = -0.010000 m 16:44:04 Magnet Current, Imag = 149.9815 A Vtrans = 1.499815 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:44:05 Hall Probe Field Measurement, B = -0.222130 T 16:44:12 Move Stage, position = 0.000000 16:44:13 Stage Position Measurement, pos = 0.000000 m 16:44:15 Magnet Current, Imag = 149.9796 A Vtrans = 1.499796 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:44:15 Hall Probe Field Measurement, B = -0.222130 T 16:44:23 Move Stage, position = 0.010000 16:44:24 Stage Position Measurement, pos = 0.010000 m 16:44:25 Magnet Current, Imag = 149.9676 A Vtrans = 1.499676 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:44:26 Hall Probe Field Measurement, B = -0.221630 T 16:44:33 Move Stage, position = 0.020000 16:44:34 Stage Position Measurement, pos = 0.020000 m 16:44:36 Magnet Current, Imag = 149.9743 A Vtrans = 1.499743 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:44:36 Hall Probe Field Measurement, B = -0.220500 T 16:44:44 Move Stage, position = 0.030000 16:44:45 Stage Position Measurement, pos = 0.030000 m 16:44:46 Magnet Current, Imag = 149.9816 A Vtrans = 1.499816 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:44:47 Hall Probe Field Measurement, B = -0.218370 T 16:44:54 Move Stage, position = 0.040000 16:44:55 Stage Position Measurement, pos = 0.040000 m 16:44:57 Magnet Current, Imag = 149.9815 A Vtrans = 1.499815 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:44:57 Hall Probe Field Measurement, B = -0.214410 T 16:45:05 Move Stage, position = 0.050000 16:45:06 Stage Position Measurement, pos = 0.050000 m 16:45:07 Magnet Current, Imag = 149.9794 A Vtrans = 1.499794 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:45:08 Hall Probe Field Measurement, B = -0.207650 T 16:45:15 Move Stage, position = 0.060000 16:45:16 Stage Position Measurement, pos = 0.060000 m 16:45:18 Magnet Current, Imag = 149.9657 A Vtrans = 1.499657 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:45:18 Hall Probe Field Measurement, B = -0.196190 T 16:45:26 Move Stage, position = 0.070000 16:45:27 Stage Position Measurement, pos = 0.070000 m 16:45:28 Magnet Current, Imag = 149.9717 A Vtrans = 1.499717 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:45:29 Hall Probe Field Measurement, B = -0.177900 T 16:45:36 Move Stage, position = 0.080000 16:45:37 Stage Position Measurement, pos = 0.080000 m 16:45:38 Magnet Current, Imag = 149.9787 A Vtrans = 1.499787 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:45:39 Hall Probe Field Measurement, B = -0.150870 T 16:45:47 Move Stage, position = 0.090000 16:45:48 Stage Position Measurement, pos = 0.090000 m 16:45:49 Magnet Current, Imag = 149.9711 A Vtrans = 1.499711 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:45:49 Hall Probe Field Measurement, B = -0.115970 T 16:45:57 Move Stage, position = 0.100000 16:45:58 Stage Position Measurement, pos = 0.100000 m 16:45:59 Magnet Current, Imag = 149.9741 A Vtrans = 1.499741 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:46:00 Hall Probe Field Measurement, B = -0.079620 T 16:46:07 Move Stage, position = 0.110000 16:46:08 Stage Position Measurement, pos = 0.110000 m 16:46:10 Magnet Current, Imag = 149.9733 A Vtrans = 1.499733 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:46:10 Hall Probe Field Measurement, B = -0.049440 T 16:46:18 Move Stage, position = 0.120000 16:46:19 Stage Position Measurement, pos = 0.120000 m 16:46:20 Magnet Current, Imag = 149.9662 A Vtrans = 1.499662 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:46:21 Hall Probe Field Measurement, B = -0.029220 T 16:46:28 Move Stage, position = 0.130000 16:46:29 Stage Position Measurement, pos = 0.130000 m 16:46:31 Magnet Current, Imag = 149.9702 A Vtrans = 1.499702 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:46:31 Hall Probe Field Measurement, B = -0.017060 T 16:46:39 Move Stage, position = 0.140000 16:46:40 Stage Position Measurement, pos = 0.140000 m 16:46:41 Magnet Current, Imag = 149.9701 A Vtrans = 1.499701 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:46:42 Hall Probe Field Measurement, B = -0.010330 T 16:46:49 Move Stage, position = 0.150000 16:46:50 Stage Position Measurement, pos = 0.150000 m 16:46:52 Magnet Current, Imag = 149.9655 A Vtrans = 1.499655 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:46:52 Hall Probe Field Measurement, B = -0.006510 T 16:47:00 Move Stage, position = 0.160000 16:47:01 Stage Position Measurement, pos = 0.160000 m 16:47:02 Magnet Current, Imag = 149.9686 A Vtrans = 1.499686 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:03 Hall Probe Field Measurement, B = -0.004330 T 16:47:10 Move Stage, position = 0.170000 16:47:11 Stage Position Measurement, pos = 0.170000 m 16:47:13 Magnet Current, Imag = 149.9729 A Vtrans = 1.499729 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:13 Hall Probe Field Measurement, B = -0.003010 T 16:47:21 Move Stage, position = 0.180000 16:47:22 Stage Position Measurement, pos = 0.180000 m 16:47:23 Magnet Current, Imag = 149.9660 A Vtrans = 1.499660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:24 Hall Probe Field Measurement, B = -0.002200 T 16:47:31 Move Stage, position = 0.190000 16:47:32 Stage Position Measurement, pos = 0.190000 m 16:47:34 Magnet Current, Imag = 149.9743 A Vtrans = 1.499743 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:34 Hall Probe Field Measurement, B = -0.001670 T 16:47:42 Move Stage, position = 0.200000 16:47:43 Stage Position Measurement, pos = 0.200000 m 16:47:44 Magnet Current, Imag = 149.9712 A Vtrans = 1.499712 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:45 Hall Probe Field Measurement, B = -0.001310 T 16:47:52 Move Stage, position = 0.210000 16:47:53 Stage Position Measurement, pos = 0.210000 m 16:47:55 Magnet Current, Imag = 149.9644 A Vtrans = 1.499644 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:55 Hall Probe Field Measurement, B = -0.001060 T 16:48:03 Move Stage, position = 0.220000 16:48:04 Stage Position Measurement, pos = 0.220000 m 16:48:05 Magnet Current, Imag = 149.9759 A Vtrans = 1.499759 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:48:06 Hall Probe Field Measurement, B = -0.000890 T 16:48:13 Move Stage, position = 0.230000 16:48:14 Stage Position Measurement, pos = 0.230000 m 16:48:16 Magnet Current, Imag = 149.9770 A Vtrans = 1.499770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:48:16 Hall Probe Field Measurement, B = -0.000740 T 16:48:24 Move Stage, position = 0.240000 16:48:25 Stage Position Measurement, pos = 0.240000 m 16:48:26 Magnet Current, Imag = 149.9675 A Vtrans = 1.499675 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:48:27 Hall Probe Field Measurement, B = -0.000650 T 16:48:34 Move Stage, position = 0.250000 16:48:35 Stage Position Measurement, pos = 0.250000 m 16:48:37 Magnet Current, Imag = 149.9595 A Vtrans = 1.499595 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:48:37 Hall Probe Field Measurement, B = -0.000560 T 16:49:31 Move Stage, position = 0.000000 16:49:35 Hall Probe Range Set, range = 5 16:49:35 Magnet current ramping to 200.0000 A... 16:51:21 Move Stage, position = -0.250000 16:51:22 Stage Position Measurement, pos = -0.250000 m 16:51:23 Magnet Current, Imag = 200.0294 A Vtrans = 2.000294 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:51:24 Hall Probe Field Measurement, B = -0.000700 T 16:51:31 Move Stage, position = -0.240000 16:51:32 Stage Position Measurement, pos = -0.240000 m 16:51:34 Magnet Current, Imag = 200.0225 A Vtrans = 2.000225 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:51:34 Hall Probe Field Measurement, B = -0.000900 T 16:51:42 Move Stage, position = -0.230000 16:51:43 Stage Position Measurement, pos = -0.230000 m 16:51:44 Magnet Current, Imag = 200.0161 A Vtrans = 2.000161 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:51:45 Hall Probe Field Measurement, B = -0.001100 T 16:51:52 Move Stage, position = -0.220000 16:51:53 Stage Position Measurement, pos = -0.220000 m 16:51:55 Magnet Current, Imag = 200.0380 A Vtrans = 2.000380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:51:56 Hall Probe Field Measurement, B = -0.001400 T 16:52:03 Move Stage, position = -0.210000 16:52:04 Stage Position Measurement, pos = -0.210000 m 16:52:06 Magnet Current, Imag = 200.0368 A Vtrans = 2.000368 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:52:06 Hall Probe Field Measurement, B = -0.001600 T 16:52:14 Move Stage, position = -0.200000 16:52:15 Stage Position Measurement, pos = -0.200000 m 16:52:16 Magnet Current, Imag = 200.0343 A Vtrans = 2.000343 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:52:17 Hall Probe Field Measurement, B = -0.002100 T 16:52:24 Move Stage, position = -0.190000 16:52:25 Stage Position Measurement, pos = -0.190000 m 16:52:27 Magnet Current, Imag = 200.0324 A Vtrans = 2.000324 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:52:27 Hall Probe Field Measurement, B = -0.002900 T 16:52:35 Move Stage, position = -0.180000 16:52:36 Stage Position Measurement, pos = -0.180000 m 16:52:37 Magnet Current, Imag = 200.0331 A Vtrans = 2.000331 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:52:38 Hall Probe Field Measurement, B = -0.004100 T 16:52:45 Move Stage, position = -0.170000 16:52:46 Stage Position Measurement, pos = -0.170000 m 16:52:48 Magnet Current, Imag = 200.0291 A Vtrans = 2.000291 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:52:48 Hall Probe Field Measurement, B = -0.005800 T 16:52:56 Move Stage, position = -0.160000 16:52:57 Stage Position Measurement, pos = -0.160000 m 16:52:58 Magnet Current, Imag = 200.0379 A Vtrans = 2.000379 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:52:59 Hall Probe Field Measurement, B = -0.009000 T 16:53:06 Move Stage, position = -0.150000 16:53:07 Stage Position Measurement, pos = -0.150000 m 16:53:09 Magnet Current, Imag = 200.0345 A Vtrans = 2.000345 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:53:09 Hall Probe Field Measurement, B = -0.014300 T 16:53:17 Move Stage, position = -0.140000 16:53:18 Stage Position Measurement, pos = -0.140000 m 16:53:19 Magnet Current, Imag = 200.0247 A Vtrans = 2.000247 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:53:20 Hall Probe Field Measurement, B = -0.024100 T 16:53:27 Move Stage, position = -0.130000 16:53:28 Stage Position Measurement, pos = -0.130000 m 16:53:30 Magnet Current, Imag = 200.0331 A Vtrans = 2.000331 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:53:30 Hall Probe Field Measurement, B = -0.041200 T 16:53:38 Move Stage, position = -0.120000 16:53:39 Stage Position Measurement, pos = -0.120000 m 16:53:40 Magnet Current, Imag = 200.0325 A Vtrans = 2.000325 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:53:41 Hall Probe Field Measurement, B = -0.070000 T 16:53:48 Move Stage, position = -0.110000 16:53:49 Stage Position Measurement, pos = -0.110000 m 16:53:50 Magnet Current, Imag = 200.0270 A Vtrans = 2.000270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:53:51 Hall Probe Field Measurement, B = -0.111300 T 16:53:59 Move Stage, position = -0.100000 16:54:00 Stage Position Measurement, pos = -0.100000 m 16:54:01 Magnet Current, Imag = 200.0239 A Vtrans = 2.000239 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:54:01 Hall Probe Field Measurement, B = -0.160100 T 16:54:09 Move Stage, position = -0.090000 16:54:10 Stage Position Measurement, pos = -0.090000 m 16:54:11 Magnet Current, Imag = 200.0227 A Vtrans = 2.000227 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:54:13 Hall Probe Field Measurement, B = -0.205500 T 16:54:20 Move Stage, position = -0.080000 16:54:21 Stage Position Measurement, pos = -0.080000 m 16:54:23 Magnet Current, Imag = 200.0235 A Vtrans = 2.000235 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:54:23 Hall Probe Field Measurement, B = -0.239900 T 16:54:31 Move Stage, position = -0.070000 16:54:32 Stage Position Measurement, pos = -0.070000 m 16:54:33 Magnet Current, Imag = 200.0295 A Vtrans = 2.000295 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:54:34 Hall Probe Field Measurement, B = -0.263100 T 16:54:41 Move Stage, position = -0.060000 16:54:42 Stage Position Measurement, pos = -0.060000 m 16:54:44 Magnet Current, Imag = 200.0268 A Vtrans = 2.000268 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:54:45 Hall Probe Field Measurement, B = -0.277400 T 16:54:52 Move Stage, position = -0.050000 16:54:54 Stage Position Measurement, pos = -0.050000 m 16:54:55 Magnet Current, Imag = 200.0198 A Vtrans = 2.000198 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:54:55 Hall Probe Field Measurement, B = -0.285900 T 16:55:03 Move Stage, position = -0.040000 16:55:04 Stage Position Measurement, pos = -0.040000 m 16:55:06 Magnet Current, Imag = 200.0159 A Vtrans = 2.000159 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:55:07 Hall Probe Field Measurement, B = -0.291000 T 16:55:14 Move Stage, position = -0.030000 16:55:15 Stage Position Measurement, pos = -0.030000 m 16:55:16 Magnet Current, Imag = 200.0285 A Vtrans = 2.000285 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:55:17 Hall Probe Field Measurement, B = -0.293800 T 16:55:25 Move Stage, position = -0.020000 16:55:26 Stage Position Measurement, pos = -0.020000 m 16:55:27 Magnet Current, Imag = 200.0382 A Vtrans = 2.000382 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:55:28 Hall Probe Field Measurement, B = -0.295400 T 16:55:35 Move Stage, position = -0.010000 16:55:36 Stage Position Measurement, pos = -0.010000 m 16:55:37 Magnet Current, Imag = 200.0257 A Vtrans = 2.000257 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:55:38 Hall Probe Field Measurement, B = -0.296000 T 16:55:46 Move Stage, position = 0.000000 16:55:47 Stage Position Measurement, pos = 0.000000 m 16:55:48 Magnet Current, Imag = 200.0252 A Vtrans = 2.000252 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:55:48 Hall Probe Field Measurement, B = -0.295900 T 16:55:56 Move Stage, position = 0.010000 16:55:57 Stage Position Measurement, pos = 0.010000 m 16:55:58 Magnet Current, Imag = 200.0254 A Vtrans = 2.000254 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:55:59 Hall Probe Field Measurement, B = -0.295400 T 16:56:07 Move Stage, position = 0.020000 16:56:08 Stage Position Measurement, pos = 0.020000 m 16:56:09 Magnet Current, Imag = 200.0259 A Vtrans = 2.000259 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:56:10 Hall Probe Field Measurement, B = -0.293800 T 16:56:17 Move Stage, position = 0.030000 16:56:18 Stage Position Measurement, pos = 0.030000 m 16:56:20 Magnet Current, Imag = 200.0242 A Vtrans = 2.000242 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:56:20 Hall Probe Field Measurement, B = -0.290900 T 16:56:28 Move Stage, position = 0.040000 16:56:29 Stage Position Measurement, pos = 0.040000 m 16:56:30 Magnet Current, Imag = 200.0218 A Vtrans = 2.000218 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:56:31 Hall Probe Field Measurement, B = -0.285700 T 16:56:38 Move Stage, position = 0.050000 16:56:39 Stage Position Measurement, pos = 0.050000 m 16:56:41 Magnet Current, Imag = 200.0308 A Vtrans = 2.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:56:41 Hall Probe Field Measurement, B = -0.276600 T 16:56:49 Move Stage, position = 0.060000 16:56:50 Stage Position Measurement, pos = 0.060000 m 16:56:51 Magnet Current, Imag = 200.0229 A Vtrans = 2.000229 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:56:52 Hall Probe Field Measurement, B = -0.261400 T 16:56:59 Move Stage, position = 0.070000 16:57:00 Stage Position Measurement, pos = 0.070000 m 16:57:02 Magnet Current, Imag = 200.0309 A Vtrans = 2.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:57:02 Hall Probe Field Measurement, B = -0.237000 T 16:57:10 Move Stage, position = 0.080000 16:57:11 Stage Position Measurement, pos = 0.080000 m 16:57:12 Magnet Current, Imag = 200.0246 A Vtrans = 2.000246 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:57:13 Hall Probe Field Measurement, B = -0.200900 T 16:57:20 Move Stage, position = 0.090000 16:57:21 Stage Position Measurement, pos = 0.090000 m 16:57:23 Magnet Current, Imag = 200.0235 A Vtrans = 2.000235 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:57:23 Hall Probe Field Measurement, B = -0.154400 T 16:57:31 Move Stage, position = 0.100000 16:57:32 Stage Position Measurement, pos = 0.100000 m 16:57:33 Magnet Current, Imag = 200.0317 A Vtrans = 2.000317 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:57:34 Hall Probe Field Measurement, B = -0.106100 T 16:57:41 Move Stage, position = 0.110000 16:57:42 Stage Position Measurement, pos = 0.110000 m 16:57:44 Magnet Current, Imag = 200.0249 A Vtrans = 2.000249 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:57:44 Hall Probe Field Measurement, B = -0.065900 T 16:57:52 Move Stage, position = 0.120000 16:57:53 Stage Position Measurement, pos = 0.120000 m 16:57:54 Magnet Current, Imag = 200.0316 A Vtrans = 2.000316 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:57:55 Hall Probe Field Measurement, B = -0.038900 T 16:58:02 Move Stage, position = 0.130000 16:58:03 Stage Position Measurement, pos = 0.130000 m 16:58:04 Magnet Current, Imag = 200.0333 A Vtrans = 2.000333 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:58:05 Hall Probe Field Measurement, B = -0.022800 T 16:58:13 Move Stage, position = 0.140000 16:58:14 Stage Position Measurement, pos = 0.140000 m 16:58:15 Magnet Current, Imag = 200.0307 A Vtrans = 2.000307 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:58:15 Hall Probe Field Measurement, B = -0.013800 T 16:58:23 Move Stage, position = 0.150000 16:58:24 Stage Position Measurement, pos = 0.150000 m 16:58:25 Magnet Current, Imag = 200.0167 A Vtrans = 2.000167 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:58:26 Hall Probe Field Measurement, B = -0.008800 T 16:58:34 Move Stage, position = 0.160000 16:58:35 Stage Position Measurement, pos = 0.160000 m 16:58:36 Magnet Current, Imag = 200.0276 A Vtrans = 2.000276 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:58:36 Hall Probe Field Measurement, B = -0.005800 T 16:58:44 Move Stage, position = 0.170000 16:58:45 Stage Position Measurement, pos = 0.170000 m 16:58:46 Magnet Current, Imag = 200.0129 A Vtrans = 2.000129 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:58:47 Hall Probe Field Measurement, B = -0.004100 T 16:58:54 Move Stage, position = 0.180000 16:58:56 Stage Position Measurement, pos = 0.180000 m 16:58:57 Magnet Current, Imag = 200.0196 A Vtrans = 2.000196 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:58:57 Hall Probe Field Measurement, B = -0.003000 T 16:59:05 Move Stage, position = 0.190000 16:59:06 Stage Position Measurement, pos = 0.190000 m 16:59:07 Magnet Current, Imag = 200.0445 A Vtrans = 2.000445 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:59:08 Hall Probe Field Measurement, B = -0.002400 T 16:59:15 Move Stage, position = 0.200000 16:59:16 Stage Position Measurement, pos = 0.200000 m 16:59:18 Magnet Current, Imag = 200.0241 A Vtrans = 2.000241 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:59:18 Hall Probe Field Measurement, B = -0.001900 T 16:59:26 Move Stage, position = 0.210000 16:59:27 Stage Position Measurement, pos = 0.210000 m 16:59:28 Magnet Current, Imag = 200.0362 A Vtrans = 2.000362 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:59:29 Hall Probe Field Measurement, B = -0.001500 T 16:59:36 Move Stage, position = 0.220000 16:59:37 Stage Position Measurement, pos = 0.220000 m 16:59:39 Magnet Current, Imag = 200.0244 A Vtrans = 2.000244 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:59:39 Hall Probe Field Measurement, B = -0.001200 T 16:59:47 Move Stage, position = 0.230000 16:59:48 Stage Position Measurement, pos = 0.230000 m 16:59:49 Magnet Current, Imag = 200.0210 A Vtrans = 2.000210 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:59:50 Hall Probe Field Measurement, B = -0.001100 T 16:59:57 Move Stage, position = 0.240000 16:59:58 Stage Position Measurement, pos = 0.240000 m 17:00:00 Magnet Current, Imag = 200.0261 A Vtrans = 2.000261 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:00:00 Hall Probe Field Measurement, B = -0.000900 T 17:00:08 Move Stage, position = 0.250000 17:00:09 Stage Position Measurement, pos = 0.250000 m 17:00:10 Magnet Current, Imag = 200.0266 A Vtrans = 2.000266 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:00:11 Hall Probe Field Measurement, B = -0.000900 T 17:01:06 Move Stage, position = 0.000000 17:01:10 Hall Probe Range Set, range = 5 17:01:10 Magnet current ramping to 220.0000 A... 17:02:44 Move Stage, position = -0.250000 17:02:45 Stage Position Measurement, pos = -0.250000 m 17:02:46 Magnet Current, Imag = 220.0405 A Vtrans = 2.200405 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:02:47 Hall Probe Field Measurement, B = -0.000900 T 17:02:54 Move Stage, position = -0.240000 17:02:55 Stage Position Measurement, pos = -0.240000 m 17:02:57 Magnet Current, Imag = 220.0453 A Vtrans = 2.200453 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:02:57 Hall Probe Field Measurement, B = -0.001000 T 17:03:05 Move Stage, position = -0.230000 17:03:06 Stage Position Measurement, pos = -0.230000 m 17:03:07 Magnet Current, Imag = 220.0351 A Vtrans = 2.200351 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:03:08 Hall Probe Field Measurement, B = -0.001200 T 17:03:15 Move Stage, position = -0.220000 17:03:16 Stage Position Measurement, pos = -0.220000 m 17:03:18 Magnet Current, Imag = 220.0405 A Vtrans = 2.200405 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:03:18 Hall Probe Field Measurement, B = -0.001500 T 17:03:26 Move Stage, position = -0.210000 17:03:27 Stage Position Measurement, pos = -0.210000 m 17:03:28 Magnet Current, Imag = 220.0511 A Vtrans = 2.200511 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:03:29 Hall Probe Field Measurement, B = -0.001900 T 17:03:36 Move Stage, position = -0.200000 17:03:37 Stage Position Measurement, pos = -0.200000 m 17:03:39 Magnet Current, Imag = 220.0349 A Vtrans = 2.200349 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:03:39 Hall Probe Field Measurement, B = -0.002400 T 17:03:47 Move Stage, position = -0.190000 17:03:48 Stage Position Measurement, pos = -0.190000 m 17:03:49 Magnet Current, Imag = 220.0339 A Vtrans = 2.200339 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:03:50 Hall Probe Field Measurement, B = -0.003200 T 17:03:57 Move Stage, position = -0.180000 17:03:58 Stage Position Measurement, pos = -0.180000 m 17:04:00 Magnet Current, Imag = 220.0456 A Vtrans = 2.200456 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:04:00 Hall Probe Field Measurement, B = -0.004500 T 17:04:08 Move Stage, position = -0.170000 17:04:09 Stage Position Measurement, pos = -0.170000 m 17:04:10 Magnet Current, Imag = 220.0347 A Vtrans = 2.200347 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:04:11 Hall Probe Field Measurement, B = -0.006500 T 17:04:18 Move Stage, position = -0.160000 17:04:19 Stage Position Measurement, pos = -0.160000 m 17:04:21 Magnet Current, Imag = 220.0327 A Vtrans = 2.200327 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:04:21 Hall Probe Field Measurement, B = -0.009900 T 17:04:29 Move Stage, position = -0.150000 17:04:30 Stage Position Measurement, pos = -0.150000 m 17:04:31 Magnet Current, Imag = 220.0458 A Vtrans = 2.200458 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:04:32 Hall Probe Field Measurement, B = -0.015900 T 17:04:39 Move Stage, position = -0.140000 17:04:40 Stage Position Measurement, pos = -0.140000 m 17:04:42 Magnet Current, Imag = 220.0395 A Vtrans = 2.200395 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:04:42 Hall Probe Field Measurement, B = -0.026600 T 17:04:50 Move Stage, position = -0.130000 17:04:51 Stage Position Measurement, pos = -0.130000 m 17:04:52 Magnet Current, Imag = 220.0410 A Vtrans = 2.200410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:04:53 Hall Probe Field Measurement, B = -0.045400 T 17:05:00 Move Stage, position = -0.120000 17:05:01 Stage Position Measurement, pos = -0.120000 m 17:05:03 Magnet Current, Imag = 220.0378 A Vtrans = 2.200378 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:05:03 Hall Probe Field Measurement, B = -0.077000 T 17:05:11 Move Stage, position = -0.110000 17:05:12 Stage Position Measurement, pos = -0.110000 m 17:05:13 Magnet Current, Imag = 220.0381 A Vtrans = 2.200381 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:05:14 Hall Probe Field Measurement, B = -0.122400 T 17:05:21 Move Stage, position = -0.100000 17:05:22 Stage Position Measurement, pos = -0.100000 m 17:05:23 Magnet Current, Imag = 220.0370 A Vtrans = 2.200370 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:05:24 Hall Probe Field Measurement, B = -0.175900 T 17:05:32 Move Stage, position = -0.090000 17:05:33 Stage Position Measurement, pos = -0.090000 m 17:05:34 Magnet Current, Imag = 220.0325 A Vtrans = 2.200325 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:05:34 Hall Probe Field Measurement, B = -0.225800 T 17:05:42 Move Stage, position = -0.080000 17:05:43 Stage Position Measurement, pos = -0.080000 m 17:05:44 Magnet Current, Imag = 220.0293 A Vtrans = 2.200293 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:05:45 Hall Probe Field Measurement, B = -0.263700 T 17:05:53 Move Stage, position = -0.070000 17:05:54 Stage Position Measurement, pos = -0.070000 m 17:05:55 Magnet Current, Imag = 220.0459 A Vtrans = 2.200459 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:05:55 Hall Probe Field Measurement, B = -0.289200 T 17:06:03 Move Stage, position = -0.060000 17:06:04 Stage Position Measurement, pos = -0.060000 m 17:06:05 Magnet Current, Imag = 220.0278 A Vtrans = 2.200278 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:06:06 Hall Probe Field Measurement, B = -0.304900 T 17:06:13 Move Stage, position = -0.050000 17:06:15 Stage Position Measurement, pos = -0.050000 m 17:06:16 Magnet Current, Imag = 220.0251 A Vtrans = 2.200251 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:06:16 Hall Probe Field Measurement, B = -0.314500 T 17:06:24 Move Stage, position = -0.040000 17:06:25 Stage Position Measurement, pos = -0.040000 m 17:06:26 Magnet Current, Imag = 220.0359 A Vtrans = 2.200359 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:06:27 Hall Probe Field Measurement, B = -0.320000 T 17:06:35 Move Stage, position = -0.030000 17:06:36 Stage Position Measurement, pos = -0.030000 m 17:06:37 Magnet Current, Imag = 220.0350 A Vtrans = 2.200350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:06:38 Hall Probe Field Measurement, B = -0.323100 T 17:06:45 Move Stage, position = -0.020000 17:06:46 Stage Position Measurement, pos = -0.020000 m 17:06:48 Magnet Current, Imag = 220.1103 A Vtrans = 2.201103 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:06:48 Hall Probe Field Measurement, B = -0.324800 T 17:06:56 Move Stage, position = -0.010000 17:06:57 Stage Position Measurement, pos = -0.010000 m 17:06:58 Magnet Current, Imag = 220.0448 A Vtrans = 2.200448 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:06:58 Hall Probe Field Measurement, B = -0.325400 T 17:07:06 Move Stage, position = 0.000000 17:07:07 Stage Position Measurement, pos = 0.000000 m 17:07:08 Magnet Current, Imag = 220.0326 A Vtrans = 2.200326 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:07:09 Hall Probe Field Measurement, B = -0.325400 T 17:07:17 Move Stage, position = 0.010000 17:07:18 Stage Position Measurement, pos = 0.010000 m 17:07:19 Magnet Current, Imag = 220.0306 A Vtrans = 2.200306 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:07:19 Hall Probe Field Measurement, B = -0.324700 T 17:07:27 Move Stage, position = 0.020000 17:07:28 Stage Position Measurement, pos = 0.020000 m 17:07:29 Magnet Current, Imag = 220.0463 A Vtrans = 2.200463 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:07:30 Hall Probe Field Measurement, B = -0.323100 T 17:07:38 Move Stage, position = 0.030000 17:07:39 Stage Position Measurement, pos = 0.030000 m 17:07:40 Magnet Current, Imag = 220.0328 A Vtrans = 2.200328 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:07:40 Hall Probe Field Measurement, B = -0.320000 T 17:07:48 Move Stage, position = 0.040000 17:07:49 Stage Position Measurement, pos = 0.040000 m 17:07:50 Magnet Current, Imag = 220.0451 A Vtrans = 2.200451 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:07:51 Hall Probe Field Measurement, B = -0.314000 T 17:07:58 Move Stage, position = 0.050000 17:08:00 Stage Position Measurement, pos = 0.050000 m 17:08:01 Magnet Current, Imag = 220.0306 A Vtrans = 2.200306 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:08:01 Hall Probe Field Measurement, B = -0.304100 T 17:08:09 Move Stage, position = 0.060000 17:08:10 Stage Position Measurement, pos = 0.060000 m 17:08:11 Magnet Current, Imag = 220.0435 A Vtrans = 2.200435 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:08:12 Hall Probe Field Measurement, B = -0.287300 T 17:08:19 Move Stage, position = 0.070000 17:08:20 Stage Position Measurement, pos = 0.070000 m 17:08:22 Magnet Current, Imag = 220.0404 A Vtrans = 2.200404 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:08:22 Hall Probe Field Measurement, B = -0.260600 T 17:08:30 Move Stage, position = 0.080000 17:08:31 Stage Position Measurement, pos = 0.080000 m 17:08:32 Magnet Current, Imag = 220.0378 A Vtrans = 2.200378 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:08:33 Hall Probe Field Measurement, B = -0.220900 T 17:08:40 Move Stage, position = 0.090000 17:08:41 Stage Position Measurement, pos = 0.090000 m 17:08:43 Magnet Current, Imag = 220.0366 A Vtrans = 2.200366 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:08:43 Hall Probe Field Measurement, B = -0.169700 T 17:08:51 Move Stage, position = 0.100000 17:08:52 Stage Position Measurement, pos = 0.100000 m 17:08:53 Magnet Current, Imag = 220.0367 A Vtrans = 2.200367 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:08:54 Hall Probe Field Measurement, B = -0.116600 T 17:09:01 Move Stage, position = 0.110000 17:09:02 Stage Position Measurement, pos = 0.110000 m 17:09:04 Magnet Current, Imag = 220.0286 A Vtrans = 2.200286 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:09:04 Hall Probe Field Measurement, B = -0.072500 T 17:09:12 Move Stage, position = 0.120000 17:09:13 Stage Position Measurement, pos = 0.120000 m 17:09:14 Magnet Current, Imag = 220.0307 A Vtrans = 2.200307 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:09:15 Hall Probe Field Measurement, B = -0.042900 T 17:09:22 Move Stage, position = 0.130000 17:09:23 Stage Position Measurement, pos = 0.130000 m 17:09:25 Magnet Current, Imag = 220.0338 A Vtrans = 2.200338 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:09:25 Hall Probe Field Measurement, B = -0.025200 T 17:09:33 Move Stage, position = 0.140000 17:09:34 Stage Position Measurement, pos = 0.140000 m 17:09:35 Magnet Current, Imag = 220.0375 A Vtrans = 2.200375 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:09:36 Hall Probe Field Measurement, B = -0.015300 T 17:09:43 Move Stage, position = 0.150000 17:09:44 Stage Position Measurement, pos = 0.150000 m 17:09:46 Magnet Current, Imag = 220.0327 A Vtrans = 2.200327 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:09:46 Hall Probe Field Measurement, B = -0.009800 T 17:09:54 Move Stage, position = 0.160000 17:09:55 Stage Position Measurement, pos = 0.160000 m 17:09:56 Magnet Current, Imag = 220.0300 A Vtrans = 2.200300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:09:57 Hall Probe Field Measurement, B = -0.006500 T 17:10:04 Move Stage, position = 0.170000 17:10:05 Stage Position Measurement, pos = 0.170000 m 17:10:07 Magnet Current, Imag = 220.0341 A Vtrans = 2.200341 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:10:07 Hall Probe Field Measurement, B = -0.004600 T 17:10:15 Move Stage, position = 0.180000 17:10:16 Stage Position Measurement, pos = 0.180000 m 17:10:17 Magnet Current, Imag = 220.0123 A Vtrans = 2.200123 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:10:18 Hall Probe Field Measurement, B = -0.003400 T 17:10:26 Move Stage, position = 0.190000 17:10:27 Stage Position Measurement, pos = 0.190000 m 17:10:28 Magnet Current, Imag = 220.0466 A Vtrans = 2.200466 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:10:28 Hall Probe Field Measurement, B = -0.002600 T 17:10:36 Move Stage, position = 0.200000 17:10:37 Stage Position Measurement, pos = 0.200000 m 17:10:38 Magnet Current, Imag = 220.0226 A Vtrans = 2.200226 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:10:39 Hall Probe Field Measurement, B = -0.002100 T 17:10:47 Move Stage, position = 0.210000 17:10:48 Stage Position Measurement, pos = 0.210000 m 17:10:49 Magnet Current, Imag = 220.0256 A Vtrans = 2.200256 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:10:49 Hall Probe Field Measurement, B = -0.001700 T 17:10:57 Move Stage, position = 0.220000 17:10:58 Stage Position Measurement, pos = 0.220000 m 17:10:59 Magnet Current, Imag = 220.0286 A Vtrans = 2.200286 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:11:00 Hall Probe Field Measurement, B = -0.001400 T 17:11:08 Move Stage, position = 0.230000 17:11:09 Stage Position Measurement, pos = 0.230000 m 17:11:10 Magnet Current, Imag = 220.0373 A Vtrans = 2.200373 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:11:10 Hall Probe Field Measurement, B = -0.001200 T 17:11:18 Move Stage, position = 0.240000 17:11:19 Stage Position Measurement, pos = 0.240000 m 17:11:20 Magnet Current, Imag = 220.0270 A Vtrans = 2.200270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:11:21 Hall Probe Field Measurement, B = -0.001100 T 17:11:28 Move Stage, position = 0.250000 17:11:29 Stage Position Measurement, pos = 0.250000 m 17:11:31 Magnet Current, Imag = 220.0358 A Vtrans = 2.200358 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:11:31 Hall Probe Field Measurement, B = -0.000900 T 17:12:27 Move Stage, position = 0.000000 17:12:28 Magnet current ramping to 0.0000 A...