SLAC Magnetic Measurements Date: 09-17-2002 Time: 15:32:24 Project: SSRL Magnet Type: Solenoid Magnet Name: GTFsolenoid_a Serial Number: Run Number: 10 Measurement Device: B9900 Hall probe Operator: zw Comment: Bz vs z, x = +10 mm, y = 0 Standardization: 1 cycles from 0.0 A to 220.0 A to 0.0 A Test Currents (A): 100.0 150.0 15:32:34 Stage Zeroed 15:32:34 MoveZ Devices: Move Device = SXDRIVE, Read Device = SXDRIVE 15:33:44 Hall Probe Zeroed 15:34:00 Hall Probe Type Being Used, type = B9900 15:34:02 Initial Zero Current Measurement, Imag_zero = 0.0000 A 15:34:02 Magnet current ramping to 25.0000 A... 15:35:05 Hall Probe Range Set, range = 5 15:35:05 Magnet current ramping to 220.0000 A... 15:36:34 Magnet current ramping to 0.0000 A... 15:38:13 Hall Probe Range Set, range = 4 15:38:13 Magnet current ramping to 100.0000 A... 15:40:10 Move Stage, position = -0.250000 15:40:11 Stage Position Measurement, pos = -0.250000 m 15:40:13 Magnet Current, Imag = 99.8792 A Vtrans = 0.998792 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:13 Hall Probe Field Measurement, B = -0.000300 T 15:40:21 Move Stage, position = -0.240000 15:40:22 Stage Position Measurement, pos = -0.240000 m 15:40:23 Magnet Current, Imag = 99.8855 A Vtrans = 0.998855 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:24 Hall Probe Field Measurement, B = -0.000350 T 15:40:31 Move Stage, position = -0.230000 15:40:32 Stage Position Measurement, pos = -0.230000 m 15:40:34 Magnet Current, Imag = 99.8793 A Vtrans = 0.998793 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:34 Hall Probe Field Measurement, B = -0.000430 T 15:40:42 Move Stage, position = -0.220000 15:40:43 Stage Position Measurement, pos = -0.220000 m 15:40:44 Magnet Current, Imag = 99.8766 A Vtrans = 0.998766 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:45 Hall Probe Field Measurement, B = -0.000530 T 15:40:52 Move Stage, position = -0.210000 15:40:53 Stage Position Measurement, pos = -0.210000 m 15:40:54 Magnet Current, Imag = 99.8848 A Vtrans = 0.998848 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:55 Hall Probe Field Measurement, B = -0.000660 T 15:41:03 Move Stage, position = -0.200000 15:41:04 Stage Position Measurement, pos = -0.200000 m 15:41:05 Magnet Current, Imag = 99.8795 A Vtrans = 0.998795 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:05 Hall Probe Field Measurement, B = -0.000840 T 15:41:13 Move Stage, position = -0.190000 15:41:14 Stage Position Measurement, pos = -0.190000 m 15:41:15 Magnet Current, Imag = 99.8819 A Vtrans = 0.998819 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:16 Hall Probe Field Measurement, B = -0.001120 T 15:41:23 Move Stage, position = -0.180000 15:41:24 Stage Position Measurement, pos = -0.180000 m 15:41:26 Magnet Current, Imag = 99.8828 A Vtrans = 0.998828 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:26 Hall Probe Field Measurement, B = -0.001530 T 15:41:34 Move Stage, position = -0.170000 15:41:35 Stage Position Measurement, pos = -0.170000 m 15:41:36 Magnet Current, Imag = 99.8873 A Vtrans = 0.998873 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:37 Hall Probe Field Measurement, B = -0.002180 T 15:41:44 Move Stage, position = -0.160000 15:41:45 Stage Position Measurement, pos = -0.160000 m 15:41:47 Magnet Current, Imag = 99.8900 A Vtrans = 0.998900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:47 Hall Probe Field Measurement, B = -0.003220 T 15:41:55 Move Stage, position = -0.150000 15:41:56 Stage Position Measurement, pos = -0.150000 m 15:41:57 Magnet Current, Imag = 99.8832 A Vtrans = 0.998832 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:58 Hall Probe Field Measurement, B = -0.004980 T 15:42:05 Move Stage, position = -0.140000 15:42:06 Stage Position Measurement, pos = -0.140000 m 15:42:07 Magnet Current, Imag = 99.8790 A Vtrans = 0.998790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:42:08 Hall Probe Field Measurement, B = -0.008110 T 15:42:16 Move Stage, position = -0.130000 15:42:17 Stage Position Measurement, pos = -0.130000 m 15:42:18 Magnet Current, Imag = 99.8836 A Vtrans = 0.998836 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:42:19 Hall Probe Field Measurement, B = -0.013800 T 15:42:27 Move Stage, position = -0.120000 15:42:28 Stage Position Measurement, pos = -0.120000 m 15:42:29 Magnet Current, Imag = 99.8879 A Vtrans = 0.998879 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:42:30 Hall Probe Field Measurement, B = -0.024050 T 15:42:37 Move Stage, position = -0.110000 15:42:38 Stage Position Measurement, pos = -0.110000 m 15:42:40 Magnet Current, Imag = 99.8862 A Vtrans = 0.998862 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:42:40 Hall Probe Field Measurement, B = -0.041090 T 15:42:48 Move Stage, position = -0.100000 15:42:49 Stage Position Measurement, pos = -0.100000 m 15:42:50 Magnet Current, Imag = 99.8818 A Vtrans = 0.998818 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:42:51 Hall Probe Field Measurement, B = -0.065160 T 15:42:58 Move Stage, position = -0.090000 15:42:59 Stage Position Measurement, pos = -0.090000 m 15:43:01 Magnet Current, Imag = 99.8837 A Vtrans = 0.998837 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:01 Hall Probe Field Measurement, B = -0.091000 T 15:43:09 Move Stage, position = -0.080000 15:43:10 Stage Position Measurement, pos = -0.080000 m 15:43:11 Magnet Current, Imag = 99.8653 A Vtrans = 0.998653 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:12 Hall Probe Field Measurement, B = -0.112270 T 15:43:19 Move Stage, position = -0.070000 15:43:20 Stage Position Measurement, pos = -0.070000 m 15:43:21 Magnet Current, Imag = 99.8833 A Vtrans = 0.998833 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:22 Hall Probe Field Measurement, B = -0.126670 T 15:43:30 Move Stage, position = -0.060000 15:43:31 Stage Position Measurement, pos = -0.060000 m 15:43:32 Magnet Current, Imag = 99.8773 A Vtrans = 0.998773 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:32 Hall Probe Field Measurement, B = -0.135900 T 15:43:40 Move Stage, position = -0.050000 15:43:41 Stage Position Measurement, pos = -0.050000 m 15:43:42 Magnet Current, Imag = 99.8823 A Vtrans = 0.998823 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:43 Hall Probe Field Measurement, B = -0.141320 T 15:43:50 Move Stage, position = -0.040000 15:43:51 Stage Position Measurement, pos = -0.040000 m 15:43:53 Magnet Current, Imag = 99.8893 A Vtrans = 0.998893 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:53 Hall Probe Field Measurement, B = -0.144590 T 15:44:01 Move Stage, position = -0.030000 15:44:02 Stage Position Measurement, pos = -0.030000 m 15:44:03 Magnet Current, Imag = 99.8708 A Vtrans = 0.998708 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:44:04 Hall Probe Field Measurement, B = -0.146400 T 15:44:11 Move Stage, position = -0.020000 15:44:12 Stage Position Measurement, pos = -0.020000 m 15:44:14 Magnet Current, Imag = 99.8720 A Vtrans = 0.998720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:44:14 Hall Probe Field Measurement, B = -0.147400 T 15:44:22 Move Stage, position = -0.010000 15:44:23 Stage Position Measurement, pos = -0.010000 m 15:44:24 Magnet Current, Imag = 99.8852 A Vtrans = 0.998852 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:44:25 Hall Probe Field Measurement, B = -0.147980 T 15:44:32 Move Stage, position = 0.000000 15:44:33 Stage Position Measurement, pos = 0.000000 m 15:44:35 Magnet Current, Imag = 99.8749 A Vtrans = 0.998749 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:44:35 Hall Probe Field Measurement, B = -0.148090 T 15:44:43 Move Stage, position = 0.010000 15:44:44 Stage Position Measurement, pos = 0.010000 m 15:44:45 Magnet Current, Imag = 99.8842 A Vtrans = 0.998842 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:44:46 Hall Probe Field Measurement, B = -0.148030 T 15:44:53 Move Stage, position = 0.020000 15:44:54 Stage Position Measurement, pos = 0.020000 m 15:44:56 Magnet Current, Imag = 99.8795 A Vtrans = 0.998795 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:44:56 Hall Probe Field Measurement, B = -0.147550 T 15:45:04 Move Stage, position = 0.030000 15:45:05 Stage Position Measurement, pos = 0.030000 m 15:45:06 Magnet Current, Imag = 99.8636 A Vtrans = 0.998636 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:07 Hall Probe Field Measurement, B = -0.146660 T 15:45:14 Move Stage, position = 0.040000 15:45:15 Stage Position Measurement, pos = 0.040000 m 15:45:16 Magnet Current, Imag = 99.8818 A Vtrans = 0.998818 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:17 Hall Probe Field Measurement, B = -0.144970 T 15:45:25 Move Stage, position = 0.050000 15:45:26 Stage Position Measurement, pos = 0.050000 m 15:45:27 Magnet Current, Imag = 99.8742 A Vtrans = 0.998742 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:27 Hall Probe Field Measurement, B = -0.141860 T 15:45:35 Move Stage, position = 0.060000 15:45:36 Stage Position Measurement, pos = 0.060000 m 15:45:37 Magnet Current, Imag = 99.8801 A Vtrans = 0.998801 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:38 Hall Probe Field Measurement, B = -0.136610 T 15:45:45 Move Stage, position = 0.070000 15:45:47 Stage Position Measurement, pos = 0.070000 m 15:45:48 Magnet Current, Imag = 99.8742 A Vtrans = 0.998742 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:48 Hall Probe Field Measurement, B = -0.127710 T 15:45:56 Move Stage, position = 0.080000 15:45:57 Stage Position Measurement, pos = 0.080000 m 15:45:58 Magnet Current, Imag = 99.8848 A Vtrans = 0.998848 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:59 Hall Probe Field Measurement, B = -0.113450 T 15:46:06 Move Stage, position = 0.090000 15:46:07 Stage Position Measurement, pos = 0.090000 m 15:46:09 Magnet Current, Imag = 99.8780 A Vtrans = 0.998780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:46:09 Hall Probe Field Measurement, B = -0.092630 T 15:46:17 Move Stage, position = 0.100000 15:46:18 Stage Position Measurement, pos = 0.100000 m 15:46:19 Magnet Current, Imag = 99.8844 A Vtrans = 0.998844 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:46:20 Hall Probe Field Measurement, B = -0.066660 T 15:46:27 Move Stage, position = 0.110000 15:46:28 Stage Position Measurement, pos = 0.110000 m 15:46:30 Magnet Current, Imag = 99.8869 A Vtrans = 0.998869 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:46:30 Hall Probe Field Measurement, B = -0.042520 T 15:46:38 Move Stage, position = 0.120000 15:46:39 Stage Position Measurement, pos = 0.120000 m 15:46:40 Magnet Current, Imag = 99.8798 A Vtrans = 0.998798 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:46:41 Hall Probe Field Measurement, B = -0.025020 T 15:46:48 Move Stage, position = 0.130000 15:46:49 Stage Position Measurement, pos = 0.130000 m 15:46:51 Magnet Current, Imag = 99.8743 A Vtrans = 0.998743 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:46:51 Hall Probe Field Measurement, B = -0.014450 T 15:46:59 Move Stage, position = 0.140000 15:47:00 Stage Position Measurement, pos = 0.140000 m 15:47:01 Magnet Current, Imag = 99.8756 A Vtrans = 0.998756 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:01 Hall Probe Field Measurement, B = -0.008540 T 15:47:09 Move Stage, position = 0.150000 15:47:10 Stage Position Measurement, pos = 0.150000 m 15:47:11 Magnet Current, Imag = 99.8672 A Vtrans = 0.998672 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:12 Hall Probe Field Measurement, B = -0.005270 T 15:47:20 Move Stage, position = 0.160000 15:47:21 Stage Position Measurement, pos = 0.160000 m 15:47:22 Magnet Current, Imag = 99.8811 A Vtrans = 0.998811 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:22 Hall Probe Field Measurement, B = -0.003440 T 15:47:30 Move Stage, position = 0.170000 15:47:31 Stage Position Measurement, pos = 0.170000 m 15:47:32 Magnet Current, Imag = 99.8751 A Vtrans = 0.998751 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:33 Hall Probe Field Measurement, B = -0.002350 T 15:47:40 Move Stage, position = 0.180000 15:47:41 Stage Position Measurement, pos = 0.180000 m 15:47:43 Magnet Current, Imag = 99.8854 A Vtrans = 0.998854 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:43 Hall Probe Field Measurement, B = -0.001680 T 15:47:51 Move Stage, position = 0.190000 15:47:52 Stage Position Measurement, pos = 0.190000 m 15:47:53 Magnet Current, Imag = 99.8848 A Vtrans = 0.998848 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:54 Hall Probe Field Measurement, B = -0.001260 T 15:48:01 Move Stage, position = 0.200000 15:48:02 Stage Position Measurement, pos = 0.200000 m 15:48:04 Magnet Current, Imag = 99.8842 A Vtrans = 0.998842 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:48:04 Hall Probe Field Measurement, B = -0.000960 T 15:48:12 Move Stage, position = 0.210000 15:48:13 Stage Position Measurement, pos = 0.210000 m 15:48:14 Magnet Current, Imag = 99.8915 A Vtrans = 0.998915 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:48:15 Hall Probe Field Measurement, B = -0.000770 T 15:48:22 Move Stage, position = 0.220000 15:48:23 Stage Position Measurement, pos = 0.220000 m 15:48:25 Magnet Current, Imag = 99.8797 A Vtrans = 0.998797 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:48:25 Hall Probe Field Measurement, B = -0.000620 T 15:48:33 Move Stage, position = 0.230000 15:48:34 Stage Position Measurement, pos = 0.230000 m 15:48:35 Magnet Current, Imag = 99.8911 A Vtrans = 0.998911 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:48:36 Hall Probe Field Measurement, B = -0.000530 T 15:48:43 Move Stage, position = 0.240000 15:48:44 Stage Position Measurement, pos = 0.240000 m 15:48:45 Magnet Current, Imag = 99.8731 A Vtrans = 0.998731 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:48:46 Hall Probe Field Measurement, B = -0.000460 T 15:48:54 Move Stage, position = 0.250000 15:48:55 Stage Position Measurement, pos = 0.250000 m 15:48:56 Magnet Current, Imag = 99.8785 A Vtrans = 0.998785 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:48:56 Hall Probe Field Measurement, B = -0.000400 T 15:49:52 Move Stage, position = 0.000000 15:49:56 Hall Probe Range Set, range = 4 15:49:56 Magnet current ramping to 150.0000 A... 15:51:38 Move Stage, position = -0.250000 15:51:39 Stage Position Measurement, pos = -0.250000 m 15:51:40 Magnet Current, Imag = 149.8786 A Vtrans = 1.498786 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:41 Hall Probe Field Measurement, B = -0.000460 T 15:51:48 Move Stage, position = -0.240000 15:51:49 Stage Position Measurement, pos = -0.240000 m 15:51:51 Magnet Current, Imag = 149.9101 A Vtrans = 1.499101 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:51 Hall Probe Field Measurement, B = -0.000540 T 15:51:59 Move Stage, position = -0.230000 15:52:00 Stage Position Measurement, pos = -0.230000 m 15:52:01 Magnet Current, Imag = 149.9097 A Vtrans = 1.499097 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:52:02 Hall Probe Field Measurement, B = -0.000650 T 15:52:09 Move Stage, position = -0.220000 15:52:10 Stage Position Measurement, pos = -0.220000 m 15:52:12 Magnet Current, Imag = 149.9223 A Vtrans = 1.499223 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:52:12 Hall Probe Field Measurement, B = -0.000810 T 15:52:20 Move Stage, position = -0.210000 15:52:21 Stage Position Measurement, pos = -0.210000 m 15:52:22 Magnet Current, Imag = 149.9056 A Vtrans = 1.499056 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:52:23 Hall Probe Field Measurement, B = -0.001010 T 15:52:30 Move Stage, position = -0.200000 15:52:31 Stage Position Measurement, pos = -0.200000 m 15:52:32 Magnet Current, Imag = 149.8952 A Vtrans = 1.498952 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:52:33 Hall Probe Field Measurement, B = -0.001280 T 15:52:41 Move Stage, position = -0.190000 15:52:42 Stage Position Measurement, pos = -0.190000 m 15:52:43 Magnet Current, Imag = 149.8918 A Vtrans = 1.498918 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:52:43 Hall Probe Field Measurement, B = -0.001700 T 15:52:51 Move Stage, position = -0.180000 15:52:52 Stage Position Measurement, pos = -0.180000 m 15:52:53 Magnet Current, Imag = 149.9045 A Vtrans = 1.499045 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:52:54 Hall Probe Field Measurement, B = -0.002330 T 15:53:02 Move Stage, position = -0.170000 15:53:03 Stage Position Measurement, pos = -0.170000 m 15:53:04 Magnet Current, Imag = 149.9012 A Vtrans = 1.499012 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:04 Hall Probe Field Measurement, B = -0.003300 T 15:53:12 Move Stage, position = -0.160000 15:53:13 Stage Position Measurement, pos = -0.160000 m 15:53:14 Magnet Current, Imag = 149.9217 A Vtrans = 1.499217 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:15 Hall Probe Field Measurement, B = -0.004850 T 15:53:22 Move Stage, position = -0.150000 15:53:23 Stage Position Measurement, pos = -0.150000 m 15:53:25 Magnet Current, Imag = 149.9139 A Vtrans = 1.499139 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:25 Hall Probe Field Measurement, B = -0.007520 T 15:53:33 Move Stage, position = -0.140000 15:53:34 Stage Position Measurement, pos = -0.140000 m 15:53:35 Magnet Current, Imag = 149.8977 A Vtrans = 1.498977 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:36 Hall Probe Field Measurement, B = -0.012190 T 15:53:43 Move Stage, position = -0.130000 15:53:44 Stage Position Measurement, pos = -0.130000 m 15:53:46 Magnet Current, Imag = 149.9182 A Vtrans = 1.499182 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:46 Hall Probe Field Measurement, B = -0.020730 T 15:53:54 Move Stage, position = -0.120000 15:53:55 Stage Position Measurement, pos = -0.120000 m 15:53:56 Magnet Current, Imag = 149.9047 A Vtrans = 1.499047 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:57 Hall Probe Field Measurement, B = -0.036100 T 15:54:04 Move Stage, position = -0.110000 15:54:05 Stage Position Measurement, pos = -0.110000 m 15:54:07 Magnet Current, Imag = 149.9032 A Vtrans = 1.499032 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:07 Hall Probe Field Measurement, B = -0.061640 T 15:54:15 Move Stage, position = -0.100000 15:54:16 Stage Position Measurement, pos = -0.100000 m 15:54:17 Magnet Current, Imag = 149.9139 A Vtrans = 1.499139 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:18 Hall Probe Field Measurement, B = -0.097710 T 15:54:25 Move Stage, position = -0.090000 15:54:26 Stage Position Measurement, pos = -0.090000 m 15:54:27 Magnet Current, Imag = 149.9045 A Vtrans = 1.499045 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:28 Hall Probe Field Measurement, B = -0.136440 T 15:54:36 Move Stage, position = -0.080000 15:54:37 Stage Position Measurement, pos = -0.080000 m 15:54:38 Magnet Current, Imag = 149.9197 A Vtrans = 1.499197 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:38 Hall Probe Field Measurement, B = -0.168330 T 15:54:46 Move Stage, position = -0.070000 15:54:47 Stage Position Measurement, pos = -0.070000 m 15:54:48 Magnet Current, Imag = 149.9198 A Vtrans = 1.499198 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:49 Hall Probe Field Measurement, B = -0.189950 T 15:54:57 Move Stage, position = -0.060000 15:54:58 Stage Position Measurement, pos = -0.060000 m 15:54:59 Magnet Current, Imag = 149.8994 A Vtrans = 1.498994 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:59 Hall Probe Field Measurement, B = -0.203810 T 15:55:07 Move Stage, position = -0.050000 15:55:08 Stage Position Measurement, pos = -0.050000 m 15:55:09 Magnet Current, Imag = 149.8972 A Vtrans = 1.498972 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:10 Hall Probe Field Measurement, B = -0.211970 T 15:55:17 Move Stage, position = -0.040000 15:55:19 Stage Position Measurement, pos = -0.040000 m 15:55:20 Magnet Current, Imag = 149.9049 A Vtrans = 1.499049 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:20 Hall Probe Field Measurement, B = -0.216860 T 15:55:28 Move Stage, position = -0.030000 15:55:29 Stage Position Measurement, pos = -0.030000 m 15:55:30 Magnet Current, Imag = 149.9064 A Vtrans = 1.499064 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:31 Hall Probe Field Measurement, B = -0.219600 T 15:55:38 Move Stage, position = -0.020000 15:55:39 Stage Position Measurement, pos = -0.020000 m 15:55:41 Magnet Current, Imag = 149.8961 A Vtrans = 1.498961 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:41 Hall Probe Field Measurement, B = -0.221090 T 15:55:49 Move Stage, position = -0.010000 15:55:50 Stage Position Measurement, pos = -0.010000 m 15:55:51 Magnet Current, Imag = 149.9060 A Vtrans = 1.499060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:52 Hall Probe Field Measurement, B = -0.221920 T 15:55:59 Move Stage, position = 0.000000 15:56:00 Stage Position Measurement, pos = 0.000000 m 15:56:02 Magnet Current, Imag = 149.9022 A Vtrans = 1.499022 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:02 Hall Probe Field Measurement, B = -0.222120 T 15:56:10 Move Stage, position = 0.010000 15:56:11 Stage Position Measurement, pos = 0.010000 m 15:56:12 Magnet Current, Imag = 149.8996 A Vtrans = 1.498996 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:13 Hall Probe Field Measurement, B = -0.222010 T 15:56:20 Move Stage, position = 0.020000 15:56:21 Stage Position Measurement, pos = 0.020000 m 15:56:23 Magnet Current, Imag = 149.9181 A Vtrans = 1.499181 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:23 Hall Probe Field Measurement, B = -0.221310 T 15:56:31 Move Stage, position = 0.030000 15:56:32 Stage Position Measurement, pos = 0.030000 m 15:56:33 Magnet Current, Imag = 149.9111 A Vtrans = 1.499111 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:34 Hall Probe Field Measurement, B = -0.219970 T 15:56:41 Move Stage, position = 0.040000 15:56:42 Stage Position Measurement, pos = 0.040000 m 15:56:44 Magnet Current, Imag = 149.9233 A Vtrans = 1.499233 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:44 Hall Probe Field Measurement, B = -0.217430 T 15:56:52 Move Stage, position = 0.050000 15:56:53 Stage Position Measurement, pos = 0.050000 m 15:56:54 Magnet Current, Imag = 149.9204 A Vtrans = 1.499204 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:55 Hall Probe Field Measurement, B = -0.212760 T 15:57:02 Move Stage, position = 0.060000 15:57:03 Stage Position Measurement, pos = 0.060000 m 15:57:04 Magnet Current, Imag = 149.9028 A Vtrans = 1.499028 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:05 Hall Probe Field Measurement, B = -0.204850 T 15:57:13 Move Stage, position = 0.070000 15:57:14 Stage Position Measurement, pos = 0.070000 m 15:57:15 Magnet Current, Imag = 149.9138 A Vtrans = 1.499138 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:15 Hall Probe Field Measurement, B = -0.191500 T 15:57:23 Move Stage, position = 0.080000 15:57:24 Stage Position Measurement, pos = 0.080000 m 15:57:25 Magnet Current, Imag = 149.9076 A Vtrans = 1.499076 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:26 Hall Probe Field Measurement, B = -0.170120 T 15:57:33 Move Stage, position = 0.090000 15:57:35 Stage Position Measurement, pos = 0.090000 m 15:57:36 Magnet Current, Imag = 149.9065 A Vtrans = 1.499065 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:36 Hall Probe Field Measurement, B = -0.138870 T 15:57:44 Move Stage, position = 0.100000 15:57:45 Stage Position Measurement, pos = 0.100000 m 15:57:46 Magnet Current, Imag = 149.9003 A Vtrans = 1.499003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:47 Hall Probe Field Measurement, B = -0.099960 T 15:57:54 Move Stage, position = 0.110000 15:57:55 Stage Position Measurement, pos = 0.110000 m 15:57:57 Magnet Current, Imag = 149.8871 A Vtrans = 1.498871 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:57 Hall Probe Field Measurement, B = -0.063770 T 15:58:05 Move Stage, position = 0.120000 15:58:06 Stage Position Measurement, pos = 0.120000 m 15:58:07 Magnet Current, Imag = 149.9087 A Vtrans = 1.499087 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:58:08 Hall Probe Field Measurement, B = -0.037550 T 15:58:15 Move Stage, position = 0.130000 15:58:16 Stage Position Measurement, pos = 0.130000 m 15:58:18 Magnet Current, Imag = 149.8953 A Vtrans = 1.498953 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:58:18 Hall Probe Field Measurement, B = -0.021690 T 15:58:26 Move Stage, position = 0.140000 15:58:27 Stage Position Measurement, pos = 0.140000 m 15:58:28 Magnet Current, Imag = 149.9061 A Vtrans = 1.499061 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:58:29 Hall Probe Field Measurement, B = -0.012830 T 15:58:36 Move Stage, position = 0.150000 15:58:37 Stage Position Measurement, pos = 0.150000 m 15:58:39 Magnet Current, Imag = 149.9102 A Vtrans = 1.499102 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:58:39 Hall Probe Field Measurement, B = -0.007940 T 15:58:47 Move Stage, position = 0.160000 15:58:48 Stage Position Measurement, pos = 0.160000 m 15:58:49 Magnet Current, Imag = 149.9128 A Vtrans = 1.499128 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:58:50 Hall Probe Field Measurement, B = -0.005180 T 15:58:57 Move Stage, position = 0.170000 15:58:58 Stage Position Measurement, pos = 0.170000 m 15:58:59 Magnet Current, Imag = 149.9165 A Vtrans = 1.499165 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:00 Hall Probe Field Measurement, B = -0.003540 T 15:59:08 Move Stage, position = 0.180000 15:59:09 Stage Position Measurement, pos = 0.180000 m 15:59:10 Magnet Current, Imag = 149.9240 A Vtrans = 1.499240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:11 Hall Probe Field Measurement, B = -0.002550 T 15:59:18 Move Stage, position = 0.190000 15:59:19 Stage Position Measurement, pos = 0.190000 m 15:59:20 Magnet Current, Imag = 149.8948 A Vtrans = 1.498948 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:22 Hall Probe Field Measurement, B = -0.001900 T 15:59:30 Move Stage, position = 0.200000 15:59:31 Stage Position Measurement, pos = 0.200000 m 15:59:32 Magnet Current, Imag = 149.8993 A Vtrans = 1.498993 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:33 Hall Probe Field Measurement, B = -0.001470 T 15:59:40 Move Stage, position = 0.210000 15:59:41 Stage Position Measurement, pos = 0.210000 m 15:59:42 Magnet Current, Imag = 149.8962 A Vtrans = 1.498962 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:43 Hall Probe Field Measurement, B = -0.001180 T 15:59:51 Move Stage, position = 0.220000 15:59:52 Stage Position Measurement, pos = 0.220000 m 15:59:53 Magnet Current, Imag = 149.8853 A Vtrans = 1.498853 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:53 Hall Probe Field Measurement, B = -0.000970 T 16:00:01 Move Stage, position = 0.230000 16:00:02 Stage Position Measurement, pos = 0.230000 m 16:00:03 Magnet Current, Imag = 149.9027 A Vtrans = 1.499027 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:00:04 Hall Probe Field Measurement, B = -0.000810 T 16:00:12 Move Stage, position = 0.240000 16:00:13 Stage Position Measurement, pos = 0.240000 m 16:00:14 Magnet Current, Imag = 149.8948 A Vtrans = 1.498948 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:00:14 Hall Probe Field Measurement, B = -0.000700 T 16:00:22 Move Stage, position = 0.250000 16:00:23 Stage Position Measurement, pos = 0.250000 m 16:00:24 Magnet Current, Imag = 149.8982 A Vtrans = 1.498982 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:00:25 Hall Probe Field Measurement, B = -0.000610 T 16:01:21 Move Stage, position = 0.000000 16:01:21 Magnet current ramping to 0.0000 A...