SLAC Magnetic Measurements Date: 09-10-2002 Time: 14:22:55 Project: SPPS Magnet Type: undulator Magnet Name: W8524A Serial Number: Run Number: 6 Measurement Device: 30 wire bundle Operator: sa Comment: Wire setup check using 2.3 cm (along z) magnet with field 0.235 T at the wire. Test Currents (A): 0.0 14:23:00 Magnet Current Measurement: Imag = 0.0000 +- 0.0000 A 14:23:00 Magnetic Field Measurement Measuring the magnet strength... 14:23:00 Integrated Voltage Measurement... 14:23:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002629656 Vs 14:23:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000577365 Vs 14:23:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002620629 Vs 14:23:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000581290 Vs 14:23:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002622389 Vs 14:23:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000579779 Vs 14:24:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002621522 Vs 14:24:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000573915 Vs 14:24:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001600818 +- 0.000002058 Vs 14:24:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 30.0 VT = -0.001600818 +- 0.000002058 Vs BL = -0.00533606 +- 0.00000686 Tm 14:24:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00534 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00534 0.00001 -0.00534 0.00000 14:24:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00534 0.00001 SL = -0.0053361 +- 0.0000069 Tm^2/m^n 14:24:18 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0053361 +- 0.0000069 Tm^2/m^n 14:24:18 Magnet Current Measurement: Imag = 0.0000 +- 0.0000 A