SLAC Magnetic Measurements
Date: 12-12-1996
Time: 16:24:28

Project: SLC
Magnet Type: DIPOLE
Magnet Name (Serial #): NDRINJ
Bar Code Number: 1
Test Stand: CLEAN ROOM
Measurement System: B9900 ULTRA MIDGET HALL PROBE.
Operator: tss
Run Number: 20
Comment: By vs x, Z = 8.0(in), Y = -0.200(in), backleg = 9.0(A), Memo ref: 6biv.

Standardization Currents
 2  cycles, 0 to  375  to 0 A
16:24:56  Probe moved to Z =  .2  cm
16:24:57  Field Measurement, B =  .00044  T
16:25:09  Probe moved to Z =  .3  cm
16:25:09  Field Measurement, B =  .00035  T
16:25:14  Probe moved to Z =  .4  cm
16:25:14  Field Measurement, B =  .00031  T
16:25:20  Probe moved to Z =  .5  cm
16:25:21  Field Measurement, B =  .00026  T
16:25:27  Probe moved to Z =  .6  cm
16:25:27  Field Measurement, B =  .00024  T
16:25:34  Probe moved to Z =  .7  cm
16:25:34  Field Measurement, B =  .00023  T
16:25:40  Probe moved to Z =  .8  cm
16:25:41  Field Measurement, B =  .00019  T
16:25:46  Probe moved to Z =  .9  cm
16:25:47  Field Measurement, B =  .00018  T
16:25:53  Probe moved to Z =  1  cm
16:25:53  Field Measurement, B =  .00016  T
16:25:53  Integrated Field Strength BL =  2.06E-06  Tm
16:27:31  Probe moved to Z =  0  cm