SLAC Magnetic Measurements
Date: 07-24-1996
Time: 14:25:32

Magnet Name: 2Q4W-29
Project: PEP II Injection Line
Test Stand: 1
Measurement Coil: DC100
Operator: J. BRATMAN
Run Number: 1
Comment: STANDARD MEASUREMENT (180 AMPS)

Standardization Currents (A):
   180.0     2.0   180.0     2.0   180.0     2.0   180.0
     2.0   180.0     2.0   180.0     2.0

Test Currents (A):
    10.0    30.0    50.0    60.0    70.0    80.0    90.0
   100.0   110.0   120.0   130.0   140.0   150.0   160.0
   180.0   150.0   100.0    50.0


                      HARMONICS MEASUREMENTS

Date: 07-24-1996
Time: 15:06:02
Magnet Name: 2Q4W-29
Project: PEP II Injection Line
Run Number: 1


                          FIELD HARMONICS

Magnet Current, Imag =  49.99308  +-  4.183142E-05  A
Coil Radius, Rcoil =  .0189973  m
Coil # Turns, Nturns =  30 
Average, # Rotations/Measurement =  8 , # Measurements =  4 

 N   BLn    sigBLn  THspole  sigTH  BLn/BL2 sBLn/BL2
     (Gm)    (Gm)    (deg)   (deg)    (%)     (%)   
--- -------+------- -------+------- -------+------- 
  1   1.001   0.007  171.86    0.07   0.699   0.005
  2 143.295   0.025  -46.02    0.01 100.000   0.000
  3   0.161   0.018  -12.44    2.73   0.112   0.013
  4   0.163   0.018  -30.06    1.03   0.114   0.013
  5   0.101   0.038  -28.62    4.74   0.070   0.027
  6   0.189   0.020   16.91    1.98   0.132   0.014
  7   0.138   0.039    1.86   12.17   0.096   0.028
  8   0.144   0.022    0.94   10.36   0.100   0.015
  9   0.039   0.021   -6.78    6.53   0.027   0.014
 10   0.283   0.011    7.94    0.19   0.197   0.008
 11   0.012   0.002   -0.84    9.67   0.008   0.001
 12   0.009   0.002   -2.26   11.23   0.006   0.001
 13   0.006   0.004   -1.69    6.00   0.004   0.003
 14   0.056   0.002    5.39    0.32   0.039   0.002
 15   0.005   0.002    2.92    8.15   0.003   0.001
 16   0.008   0.004   -0.27    6.94   0.005   0.003


The magnetic center is at
X =    18.8 +-     0.2 microns
Y =  -131.4 +-     0.9 microns

The magnetic center is measured relative to the coil axis
effectively at the longitudinal center of the magnet.
Pitch and yaw are not seen by the coil.

View from the non lead end of the magnet:

           y          
           ^          
           |          
        S     N       

                --> x 

        N     S       

Date: 07-24-1996
Time: 15:38:39
Magnet Name: 2Q4W-29
Project: PEP II Injection Line
Run Number: 1


                          FIELD HARMONICS

Magnet Current, Imag =  109.9684  +-  2.609933E-04  A
Coil Radius, Rcoil =  .0189973  m
Coil # Turns, Nturns =  30 
Average, # Rotations/Measurement =  8 , # Measurements =  4 

 N   BLn    sigBLn  THspole  sigTH  BLn/BL2 sBLn/BL2
     (Gm)    (Gm)    (deg)   (deg)    (%)     (%)   
--- -------+------- -------+------- -------+------- 
  1   2.023   0.010  167.67    0.11   0.642   0.004
  2 315.162   0.166  -45.97    0.00 100.000   0.000
  3   0.444   0.026  -15.00    2.74   0.141   0.008
  4   0.371   0.011  -28.97    0.46   0.118   0.003
  5   0.207   0.052  -27.71    2.84   0.066   0.017
  6   0.405   0.163   14.56    2.37   0.128   0.052
  7   0.328   0.083   -2.75   10.28   0.104   0.026
  8   0.286   0.104   -0.52   10.85   0.091   0.033
  9   0.065   0.038   -0.52    9.91   0.020   0.012
 10   0.616   0.022    8.02    0.17   0.196   0.007
 11   0.016   0.013    0.40   10.66   0.005   0.004
 12   0.017   0.009    2.19   10.24   0.005   0.003
 13   0.020   0.011    4.05    6.65   0.006   0.003
 14   0.128   0.005    5.24    0.04   0.041   0.002
 15   0.009   0.001    6.49    3.85   0.003   0.000
 16   0.012   0.007    1.07    4.60   0.004   0.002


The magnetic center is at
X =    26.0 +-     0.3 microns
Y =  -119.1 +-     0.6 microns

The magnetic center is measured relative to the coil axis
effectively at the longitudinal center of the magnet.
Pitch and yaw are not seen by the coil.

View from the non lead end of the magnet:

           y          
           ^          
           |          
        S     N       

                --> x 

        N     S       

Date: 07-24-1996
Time: 16:11:20
Magnet Name: 2Q4W-29
Project: PEP II Injection Line
Run Number: 1


                          FIELD HARMONICS

Magnet Current, Imag =  179.9591  +-  3.899957E-04  A
Coil Radius, Rcoil =  .0189973  m
Coil # Turns, Nturns =  30 
Average, # Rotations/Measurement =  8 , # Measurements =  4 

 N   BLn    sigBLn  THspole  sigTH  BLn/BL2 sBLn/BL2
     (Gm)    (Gm)    (deg)   (deg)    (%)     (%)   
--- -------+------- -------+------- -------+------- 
  1   3.237   0.020  167.28    0.11   0.631   0.004
  2 512.997   0.253  -46.05    0.00 100.000   0.000
  3   0.707   0.027  -14.19    2.60   0.138   0.005
  4   0.589   0.005  -29.71    0.93   0.115   0.001
  5   0.354   0.087  -27.86    3.56   0.069   0.017
  6   0.776   0.290   15.18    3.47   0.151   0.056
  7   0.583   0.177    0.61   10.47   0.114   0.035
  8   0.496   0.137   -7.41   12.34   0.097   0.027
  9   0.113   0.054   -5.14    9.94   0.022   0.010
 10   1.017   0.041    7.98    0.20   0.198   0.008
 11   0.019   0.007   -0.19   12.84   0.004   0.001
 12   0.028   0.012   -3.44    7.79   0.005   0.002
 13   0.033   0.015   -5.53    5.12   0.007   0.003
 14   0.206   0.006    5.33    0.08   0.040   0.001
 15   0.014   0.005    3.89    8.03   0.003   0.001
 16   0.019   0.007   -2.21    7.41   0.004   0.001


The magnetic center is at
X =    26.4 +-     0.3 microns
Y =  -116.9 +-     0.7 microns

The magnetic center is measured relative to the coil axis
effectively at the longitudinal center of the magnet.
Pitch and yaw are not seen by the coil.

View from the non lead end of the magnet:

           y          
           ^          
           |          
        S     N       

                --> x 

        N     S       


           SUMMARY OF THE CALCULATIONS AND CONVENTIONS USED


Calculation of GL using a double coil (assumed flat):
V2 = (Nturns * velocity * B2 * L)_1 + (Nturns * velocity * B2 * L)_2
   = (Nturns1 * Rcoil1 * ang_freq * GL * Rcoil1)
          + (Nturns2 * Rcoil2 * ang_freq * GL * Rcoil2)
   = (Nturns1 * Rcoil1^2 + Nturns2 * Rcoil2^2) * ang_freq * GL
If Nturns1 = Nturns2 == Nturns12, then
V2 = Nturns12 * (Rcoil1^2 + Rcoil2^2) * ang_freq * GL
Let Reff^2 = Rcoil1^2 + Rcoil2^2, then
V2 = Nturns12 * Reff^2 * ang_freq * GL
Or,
GL = V2 / (Nturns12 * Reff^2 * ang_freq)


Calculation of the harmonics:
The integrated radial field for the n'th harmonic at the
coil radius is given by
BLn(th) = BLn * cos(n*(th - THspole))
The coil voltage is V = Nturns * v_theta * B_r * L
Vn(th) = Nturns * velocity * BLn(th)
       = Nturns * Rcoil * ang_freq * BLn * cos(n*(th - THspole))
The FFT gives Vn and PhiVn in the formula
Vn(i) = Vn * cos(n*2pi*i/N + PhiVn)
Then,
Vn = Nturns * Rcoil * ang_freq * BLn
PhiVn = - n * THspole
Or,
BLn = Vn / (Nturns * Rcoil * ang_freq)
THspole = - PhiVn / n


Calculation of the magnetic center:
Xcenter = - (1/GL) * BL1 * sin(THspole1)
Ycenter = - (1/GL) * BL1 * cos(THspole1)