SLAC Magnetic Measurements Date: 03-06-1995 Time: 15:08:12 Magnet Name: 2Q10-08 Project: PEP II Injection Line Test Stand: Rotating Coil Stand 2 Measurement Coil: DC100 Operator: STEVEN GARCIA Run Number: 1 Comment: STANDARD MEASUREMENT Standardization Currents (A): 160.0 2.0 160.0 2.0 160.0 2.0 Test Currents (A): 10.0 30.0 45.0 60.0 75.0 90.0 100.0 110.0 125.0 140.0 160.0 130.0 100.0 60.0 15:12:38 Magnet Current, Imag = -9.425E-05 A 15:12:38 Ramping magnet to 10 A... 15:14:26 Magnet Current, Imag = -.0000725 A 15:14:28 Magnet Current, Imag = -1.2825E-04 A 15:14:30 Magnet Current, Imag = -.000144 A 15:14:32 Magnet Current, Imag = -1.2425E-04 A 15:14:34 Magnet Current, Imag = -.0000625 A 15:14:34 Magnet Current Measurement: Imag = -1.1475E-04 +- 3.10569E-05 A 15:14:38 Coil Rotation Frequency, Fcoil = 6.702754 Hz