SLAC Magnetic Measurements Date: 11-20-1995 Time: 11:07:39 Project: PEPII-SIT Magnet Name (Serial #): B2_2 Bar Code Number: Test Stand: MAGMEAS2 Measurement Coil: STRETCHED-WIRE Operator: PHIL RADUSEWICZ Run Number: 8 Comment: Measure Bdl vs X @ 264A, Repeatability Standardization Currents 3 cycles, 0 to 490 to 0 A 11:09:52 Power Supply 1 Current, Ips = .010346 A 11:09:52 Magnet Current, Imag = .010346 A 11:09:52 Magnet Current Ramping to 490 A... 11:12:16 Power Supply 1 Current, Ips = 493.7288 A 11:12:16 Magnet Current, Imag = 493.7288 A 11:12:19 Power Supply 1 Current, Ips = 493.7004 A 11:12:19 Magnet Current, Imag = 493.7004 A 11:12:19 Magnet Current Ramping to 5 A... 11:14:41 Power Supply 1 Current, Ips = 4.877598 A 11:14:41 Magnet Current, Imag = 4.877598 A 11:14:45 Power Supply 1 Current, Ips = 4.853016 A 11:14:45 Magnet Current, Imag = 4.853016 A 11:14:45 Magnet Current Ramping to 490 A... 11:17:08 Power Supply 1 Current, Ips = 493.8536 A 11:17:09 Magnet Current, Imag = 493.8536 A 11:17:11 Power Supply 1 Current, Ips = 493.7626 A 11:17:11 Magnet Current, Imag = 493.7626 A 11:17:11 Magnet Current Ramping to 5 A... 11:19:34 Power Supply 1 Current, Ips = 4.860216 A 11:19:34 Magnet Current, Imag = 4.860216 A 11:19:38 Power Supply 1 Current, Ips = 4.863518 A 11:19:38 Magnet Current, Imag = 4.863518 A 11:19:38 Magnet Current Ramping to 490 A... 11:22:01 Power Supply 1 Current, Ips = 493.8064 A 11:22:01 Magnet Current, Imag = 493.8064 A 11:22:04 Power Supply 1 Current, Ips = 493.7878 A 11:22:04 Magnet Current, Imag = 493.7878 A 11:22:04 Magnet Current Ramping to 5 A... 11:24:26 Power Supply 1 Current, Ips = 4.873432 A 11:24:26 Magnet Current, Imag = 4.873432 A 11:26:20 Power Supply 1 Current, Ips = 4.87444 A 11:26:20 Magnet Current, Imag = 4.87444 A 11:26:20 Magnet Current Ramping to 264 A... 11:29:56 Power Supply 1 Current, Ips = 266.1022 A 11:29:56 Magnet Current, Imag = 266.1022 A 11:29:59 Power Supply 1 Current, Ips = 266.0686 A 11:29:59 Magnet Current, Imag = 266.0686 A 11:30:00 Power Supply 1 Current, Ips = 266.085 A 11:30:00 Magnet Current, Imag = 266.085 A 11:30:01 Power Supply 1 Current, Ips = 266.0848 A 11:30:01 Magnet Current, Imag = 266.0848 A 11:30:03 Power Supply 1 Current, Ips = 266.0844 A 11:30:03 Magnet Current, Imag = 266.0844 A 11:30:03 Magnet Current Measurement: Imag = 266.0807 +- 6.993937E-03 A 11:30:12 Wire moved to X = -3 cm 11:30:17 Wire moved by DX = 1 cm 11:30:26 X0 = -2.5 cm, dx = 1 cm, VT = 8.785782E-03 VS 11:30:28 Wire moved to X = -2 cm 11:30:32 Wire moved by DX = -1 cm 11:30:42 X0 = -2.5 cm, dx = -1 cm, VT = -8.784564E-03 VS 11:30:44 Wire moved to X = -3 cm 11:30:48 Wire moved by DX = 1 cm 11:30:58 X0 = -2.5 cm, dx = 1 cm, VT = 8.773528E-03 VS 11:30:59 Wire moved to X = -2 cm 11:31:04 Wire moved by DX = -1 cm 11:31:14 X0 = -2.5 cm, dx = -1 cm, VT = -8.770211E-03 VS 11:31:15 Wire moved to X = -3 cm 11:31:19 Wire moved by DX = 1 cm 11:31:29 X0 = -2.5 cm, dx = 1 cm, VT = 8.765935E-03 VS 11:31:31 Wire moved to X = -2 cm 11:31:35 Wire moved by DX = -1 cm 11:31:45 X0 = -2.5 cm, dx = -1 cm, VT = -8.797634E-03 VS 11:31:46 Wire moved to X = -3 cm 11:31:51 Wire moved by DX = 1 cm 11:32:01 X0 = -2.5 cm, dx = 1 cm, VT = 8.756697E-03 VS 11:32:03 Wire moved to X = -2 cm 11:32:07 Wire moved by DX = -1 cm 11:32:17 X0 = -2.5 cm, dx = -1 cm, VT = -8.773983E-03 VS 11:32:17 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -2.5 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 8.776043E-03 +- 7.878947E-06 VS (= Tm^2) 11:32:20 Power Supply 1 Current, Ips = 266.0818 A 11:32:20 Magnet Current, Imag = 266.0818 A 11:32:21 Power Supply 1 Current, Ips = 266.0948 A 11:32:21 Magnet Current, Imag = 266.0948 A 11:32:22 Power Supply 1 Current, Ips = 266.0524 A 11:32:22 Magnet Current, Imag = 266.0524 A 11:32:24 Power Supply 1 Current, Ips = 266.0922 A 11:32:24 Magnet Current, Imag = 266.0922 A 11:32:24 Magnet Current Measurement: Imag = 266.0803 +- 1.683558E-02 A 11:32:26 Wire moved to X = -2.5 cm 11:32:31 Wire moved by DX = 1 cm 11:32:41 X0 = -2 cm, dx = 1 cm, VT = 1.105614E-02 VS 11:32:42 Wire moved to X = -1.5 cm 11:32:46 Wire moved by DX = -1 cm 11:32:56 X0 = -2 cm, dx = -1 cm, VT = -1.107568E-02 VS 11:32:58 Wire moved to X = -2.5 cm 11:33:02 Wire moved by DX = 1 cm 11:33:12 X0 = -2 cm, dx = 1 cm, VT = 1.104579E-02 VS 11:33:13 Wire moved to X = -1.5 cm 11:33:18 Wire moved by DX = -1 cm 11:33:28 X0 = -2 cm, dx = -1 cm, VT = -1.108155E-02 VS 11:33:29 Wire moved to X = -2.5 cm 11:33:34 Wire moved by DX = 1 cm 11:33:43 X0 = -2 cm, dx = 1 cm, VT = 1.105618E-02 VS 11:33:45 Wire moved to X = -1.5 cm 11:33:49 Wire moved by DX = -1 cm 11:33:59 X0 = -2 cm, dx = -1 cm, VT = -1.107862E-02 VS 11:34:00 Wire moved to X = -2.5 cm 11:34:05 Wire moved by DX = 1 cm 11:34:15 X0 = -2 cm, dx = 1 cm, VT = 1.105764E-02 VS 11:34:16 Wire moved to X = -1.5 cm 11:34:21 Wire moved by DX = -1 cm 11:34:31 X0 = -2 cm, dx = -1 cm, VT = -1.105404E-02 VS 11:34:31 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -2 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = .0110632 +- 4.455133E-06 VS (= Tm^2) 11:34:32 Power Supply 1 Current, Ips = 266.0652 A 11:34:32 Magnet Current, Imag = 266.0652 A 11:34:33 Power Supply 1 Current, Ips = 266.0806 A 11:34:33 Magnet Current, Imag = 266.0806 A 11:34:35 Power Supply 1 Current, Ips = 266.0408 A 11:34:35 Magnet Current, Imag = 266.0408 A 11:34:36 Power Supply 1 Current, Ips = 266.1214 A 11:34:36 Magnet Current, Imag = 266.1214 A 11:34:36 Magnet Current Measurement: Imag = 266.077 +- 2.931207E-02 A 11:34:39 Wire moved to X = -2 cm 11:34:43 Wire moved by DX = 1 cm 11:34:53 X0 = -1.5 cm, dx = 1 cm, VT = 1.105096E-02 VS 11:34:54 Wire moved to X = -1 cm 11:34:59 Wire moved by DX = -1 cm 11:35:08 X0 = -1.5 cm, dx = -1 cm, VT = -1.105723E-02 VS 11:35:10 Wire moved to X = -2 cm 11:35:14 Wire moved by DX = 1 cm 11:35:24 X0 = -1.5 cm, dx = 1 cm, VT = 1.105005E-02 VS 11:35:26 Wire moved to X = -1 cm 11:35:30 Wire moved by DX = -1 cm 11:35:40 X0 = -1.5 cm, dx = -1 cm, VT = -1.107972E-02 VS 11:35:41 Wire moved to X = -2 cm 11:35:46 Wire moved by DX = 1 cm 11:35:56 X0 = -1.5 cm, dx = 1 cm, VT = 1.106641E-02 VS 11:35:57 Wire moved to X = -1 cm 11:36:02 Wire moved by DX = -1 cm 11:36:12 X0 = -1.5 cm, dx = -1 cm, VT = -1.106732E-02 VS 11:36:13 Wire moved to X = -2 cm 11:36:17 Wire moved by DX = 1 cm 11:36:27 X0 = -1.5 cm, dx = 1 cm, VT = 1.105736E-02 VS 11:36:29 Wire moved to X = -1 cm 11:36:33 Wire moved by DX = -1 cm 11:36:43 X0 = -1.5 cm, dx = -1 cm, VT = -1.106248E-02 VS 11:36:43 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -1.5 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.106144E-02 +- 4.938766E-06 VS (= Tm^2) 11:36:44 Power Supply 1 Current, Ips = 266.1 A 11:36:44 Magnet Current, Imag = 266.1 A 11:36:46 Power Supply 1 Current, Ips = 266.1082 A 11:36:46 Magnet Current, Imag = 266.1082 A 11:36:47 Power Supply 1 Current, Ips = 266.0874 A 11:36:47 Magnet Current, Imag = 266.0874 A 11:36:48 Power Supply 1 Current, Ips = 266.0788 A 11:36:48 Magnet Current, Imag = 266.0788 A 11:36:48 Magnet Current Measurement: Imag = 266.0936 +- 1.130599E-02 A 11:36:51 Wire moved to X = -1.5 cm 11:36:55 Wire moved by DX = 1 cm 11:37:05 X0 = -1 cm, dx = 1 cm, VT = 1.106054E-02 VS 11:37:07 Wire moved to X = -.5 cm 11:37:12 Wire moved by DX = -1 cm 11:37:21 X0 = -1 cm, dx = -1 cm, VT = -1.105957E-02 VS 11:37:23 Wire moved to X = -1.5 cm 11:37:27 Wire moved by DX = 1 cm 11:37:37 X0 = -1 cm, dx = 1 cm, VT = 1.106031E-02 VS 11:37:39 Wire moved to X = -.5 cm 11:37:43 Wire moved by DX = -1 cm 11:37:53 X0 = -1 cm, dx = -1 cm, VT = -1.107165E-02 VS 11:37:54 Wire moved to X = -1.5 cm 11:37:59 Wire moved by DX = 1 cm 11:38:09 X0 = -1 cm, dx = 1 cm, VT = .0110407 VS 11:38:10 Wire moved to X = -.5 cm 11:38:15 Wire moved by DX = -1 cm 11:38:25 X0 = -1 cm, dx = -1 cm, VT = -1.107615E-02 VS 11:38:26 Wire moved to X = -1.5 cm 11:38:31 Wire moved by DX = 1 cm 11:38:40 X0 = -1 cm, dx = 1 cm, VT = 1.105606E-02 VS 11:38:42 Wire moved to X = -.5 cm 11:38:46 Wire moved by DX = -1 cm 11:38:56 X0 = -1 cm, dx = -1 cm, VT = -1.105348E-02 VS 11:38:56 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -1 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.105981E-02 +- 4.044009E-06 VS (= Tm^2) 11:38:58 Power Supply 1 Current, Ips = 266.083 A 11:38:58 Magnet Current, Imag = 266.083 A 11:38:59 Power Supply 1 Current, Ips = 266.1102 A 11:38:59 Magnet Current, Imag = 266.1102 A 11:39:01 Power Supply 1 Current, Ips = 266.094 A 11:39:01 Magnet Current, Imag = 266.094 A 11:39:02 Power Supply 1 Current, Ips = 266.106 A 11:39:02 Magnet Current, Imag = 266.106 A 11:39:02 Magnet Current Measurement: Imag = 266.0983 +- 1.064833E-02 A 11:39:05 Wire moved to X = -1 cm 11:39:09 Wire moved by DX = 1 cm 11:39:19 X0 = -.5 cm, dx = 1 cm, VT = 1.106119E-02 VS 11:39:20 Wire moved to X = 0 cm 11:39:25 Wire moved by DX = -1 cm 11:39:35 X0 = -.5 cm, dx = -1 cm, VT = -1.107196E-02 VS 11:39:36 Wire moved to X = -1 cm 11:39:41 Wire moved by DX = 1 cm 11:39:50 X0 = -.5 cm, dx = 1 cm, VT = 1.105926E-02 VS 11:39:52 Wire moved to X = 0 cm 11:39:56 Wire moved by DX = -1 cm 11:40:06 X0 = -.5 cm, dx = -1 cm, VT = -1.105306E-02 VS 11:40:07 Wire moved to X = -1 cm 11:40:12 Wire moved by DX = 1 cm 11:40:22 X0 = -.5 cm, dx = 1 cm, VT = 1.103885E-02 VS 11:40:23 Wire moved to X = 0 cm 11:40:28 Wire moved by DX = -1 cm 11:40:38 X0 = -.5 cm, dx = -1 cm, VT = -.0110557 VS 11:40:39 Wire moved to X = -1 cm 11:40:43 Wire moved by DX = 1 cm 11:40:53 X0 = -.5 cm, dx = 1 cm, VT = 1.105259E-02 VS 11:40:55 Wire moved to X = 0 cm 11:40:59 Wire moved by DX = -1 cm 11:41:09 X0 = -.5 cm, dx = -1 cm, VT = -1.109842E-02 VS 11:41:09 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -.5 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.106138E-02 +- 1.063822E-05 VS (= Tm^2) 11:41:10 Power Supply 1 Current, Ips = 266.108 A 11:41:10 Magnet Current, Imag = 266.108 A 11:41:12 Power Supply 1 Current, Ips = 266.108 A 11:41:12 Magnet Current, Imag = 266.108 A 11:41:13 Power Supply 1 Current, Ips = 266.1034 A 11:41:13 Magnet Current, Imag = 266.1034 A 11:41:14 Power Supply 1 Current, Ips = 266.0994 A 11:41:14 Magnet Current, Imag = 266.0994 A 11:41:14 Magnet Current Measurement: Imag = 266.1047 +- 3.579251E-03 A 11:41:17 Wire moved to X = -.5 cm 11:41:21 Wire moved by DX = 1 cm 11:41:31 X0 = 0 cm, dx = 1 cm, VT = 1.107747E-02 VS 11:41:32 Wire moved to X = .5 cm 11:41:37 Wire moved by DX = -1 cm 11:41:47 X0 = 0 cm, dx = -1 cm, VT = -1.105712E-02 VS 11:41:48 Wire moved to X = -.5 cm 11:41:52 Wire moved by DX = 1 cm 11:42:02 X0 = 0 cm, dx = 1 cm, VT = 1.106107E-02 VS 11:42:04 Wire moved to X = .5 cm 11:42:08 Wire moved by DX = -1 cm 11:42:18 X0 = 0 cm, dx = -1 cm, VT = -1.105366E-02 VS 11:42:19 Wire moved to X = -.5 cm 11:42:24 Wire moved by DX = 1 cm 11:42:36 X0 = 0 cm, dx = 1 cm, VT = 1.103988E-02 VS 11:42:37 Wire moved to X = .5 cm 11:42:42 Wire moved by DX = -1 cm 11:42:52 X0 = 0 cm, dx = -1 cm, VT = -1.103305E-02 VS 11:42:53 Wire moved to X = -.5 cm 11:42:57 Wire moved by DX = 1 cm 11:43:07 X0 = 0 cm, dx = 1 cm, VT = 1.104359E-02 VS 11:43:09 Wire moved to X = .5 cm 11:43:13 Wire moved by DX = -1 cm 11:43:23 X0 = 0 cm, dx = -1 cm, VT = -1.107842E-02 VS 11:43:23 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.105553E-02 +- 1.156628E-05 VS (= Tm^2) 11:43:26 Power Supply 1 Current, Ips = 266.0764 A 11:43:26 Magnet Current, Imag = 266.0764 A 11:43:27 Power Supply 1 Current, Ips = 266.0772 A 11:43:27 Magnet Current, Imag = 266.0772 A 11:43:28 Power Supply 1 Current, Ips = 266.0844 A 11:43:28 Magnet Current, Imag = 266.0844 A 11:43:30 Power Supply 1 Current, Ips = 266.0918 A 11:43:30 Magnet Current, Imag = 266.0918 A 11:43:30 Magnet Current Measurement: Imag = 266.0825 +- 6.226633E-03 A 11:43:32 Wire moved to X = 0 cm 11:43:37 Wire moved by DX = 1 cm 11:43:46 X0 = .5 cm, dx = 1 cm, VT = 1.106758E-02 VS 11:43:48 Wire moved to X = 1 cm 11:43:52 Wire moved by DX = -1 cm 11:44:02 X0 = .5 cm, dx = -1 cm, VT = -1.106429E-02 VS 11:44:03 Wire moved to X = 0 cm 11:44:08 Wire moved by DX = 1 cm 11:44:18 X0 = .5 cm, dx = 1 cm, VT = 1.103156E-02 VS 11:44:19 Wire moved to X = 1 cm 11:44:24 Wire moved by DX = -1 cm 11:44:34 X0 = .5 cm, dx = -1 cm, VT = -1.108001E-02 VS 11:44:35 Wire moved to X = 0 cm 11:44:39 Wire moved by DX = 1 cm 11:44:49 X0 = .5 cm, dx = 1 cm, VT = 1.106901E-02 VS 11:44:51 Wire moved to X = 1 cm 11:44:55 Wire moved by DX = -1 cm 11:45:05 X0 = .5 cm, dx = -1 cm, VT = -1.107688E-02 VS 11:45:06 Wire moved to X = 0 cm 11:45:11 Wire moved by DX = 1 cm 11:45:21 X0 = .5 cm, dx = 1 cm, VT = 1.105063E-02 VS 11:45:22 Wire moved to X = 1 cm 11:45:27 Wire moved by DX = -1 cm 11:45:37 X0 = .5 cm, dx = -1 cm, VT = -1.107445E-02 VS 11:45:37 Integrated Voltage Measurement: Center Of Wire Motion, X0 = .5 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = .0110643 +- 6.184931E-06 VS (= Tm^2) 11:45:38 Power Supply 1 Current, Ips = 266.0844 A 11:45:38 Magnet Current, Imag = 266.0844 A 11:45:39 Power Supply 1 Current, Ips = 266.098 A 11:45:39 Magnet Current, Imag = 266.098 A 11:45:41 Power Supply 1 Current, Ips = 266.0828 A 11:45:41 Magnet Current, Imag = 266.0828 A 11:45:42 Power Supply 1 Current, Ips = 266.1118 A 11:45:42 Magnet Current, Imag = 266.1118 A 11:45:42 Magnet Current Measurement: Imag = 266.0942 +- 1.172512E-02 A 11:45:44 Wire moved to X = .5 cm 11:45:49 Wire moved by DX = 1 cm 11:45:59 X0 = 1 cm, dx = 1 cm, VT = 1.105997E-02 VS 11:46:00 Wire moved to X = 1.5 cm 11:46:05 Wire moved by DX = -1 cm 11:46:14 X0 = 1 cm, dx = -1 cm, VT = -1.105146E-02 VS 11:46:16 Wire moved to X = .5 cm 11:46:20 Wire moved by DX = 1 cm 11:46:30 X0 = 1 cm, dx = 1 cm, VT = 1.103227E-02 VS 11:46:31 Wire moved to X = 1.5 cm 11:46:36 Wire moved by DX = -1 cm 11:46:46 X0 = 1 cm, dx = -1 cm, VT = -1.108039E-02 VS 11:46:47 Wire moved to X = .5 cm 11:46:52 Wire moved by DX = 1 cm 11:47:02 X0 = 1 cm, dx = 1 cm, VT = .0110266 VS 11:47:03 Wire moved to X = 1.5 cm 11:47:07 Wire moved by DX = -1 cm 11:47:17 X0 = 1 cm, dx = -1 cm, VT = -1.106588E-02 VS 11:47:19 Wire moved to X = .5 cm 11:47:23 Wire moved by DX = 1 cm 11:47:33 X0 = 1 cm, dx = 1 cm, VT = 1.102989E-02 VS 11:47:34 Wire moved to X = 1.5 cm 11:47:39 Wire moved by DX = -1 cm 11:47:49 X0 = 1 cm, dx = -1 cm, VT = -1.106758E-02 VS 11:47:49 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 1 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.105175E-02 +- 4.362016E-06 VS (= Tm^2) 11:47:51 Power Supply 1 Current, Ips = 266.1036 A 11:47:51 Magnet Current, Imag = 266.1036 A 11:47:52 Power Supply 1 Current, Ips = 266.1062 A 11:47:52 Magnet Current, Imag = 266.1062 A 11:47:54 Power Supply 1 Current, Ips = 266.1562 A 11:47:54 Magnet Current, Imag = 266.1562 A 11:47:56 Power Supply 1 Current, Ips = 266.088 A 11:47:56 Magnet Current, Imag = 266.088 A 11:47:56 Magnet Current Measurement: Imag = 266.1135 +- 2.560807E-02 A 11:47:59 Wire moved to X = 1 cm 11:48:03 Wire moved by DX = 1 cm 11:48:13 X0 = 1.5 cm, dx = 1 cm, VT = 1.103907E-02 VS 11:48:15 Wire moved to X = 2 cm 11:48:19 Wire moved by DX = -1 cm 11:48:29 X0 = 1.5 cm, dx = -1 cm, VT = -1.105051E-02 VS 11:48:31 Wire moved to X = 1 cm 11:48:35 Wire moved by DX = 1 cm 11:48:45 X0 = 1.5 cm, dx = 1 cm, VT = 1.106256E-02 VS 11:48:47 Wire moved to X = 2 cm 11:48:51 Wire moved by DX = -1 cm 11:49:01 X0 = 1.5 cm, dx = -1 cm, VT = -1.107264E-02 VS 11:49:02 Wire moved to X = 1 cm 11:49:07 Wire moved by DX = 1 cm 11:49:17 X0 = 1.5 cm, dx = 1 cm, VT = 1.103096E-02 VS 11:49:18 Wire moved to X = 2 cm 11:49:22 Wire moved by DX = -1 cm 11:49:32 X0 = 1.5 cm, dx = -1 cm, VT = -1.103292E-02 VS 11:49:34 Wire moved to X = 1 cm 11:49:38 Wire moved by DX = 1 cm 11:49:48 X0 = 1.5 cm, dx = 1 cm, VT = .0110648 VS 11:49:49 Wire moved to X = 2 cm 11:49:54 Wire moved by DX = -1 cm 11:50:04 X0 = 1.5 cm, dx = -1 cm, VT = -1.102927E-02 VS 11:50:04 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 1.5 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.104784E-02 +- 1.277923E-05 VS (= Tm^2) 11:50:05 Power Supply 1 Current, Ips = 266.0962 A 11:50:06 Magnet Current, Imag = 266.0962 A 11:50:07 Power Supply 1 Current, Ips = 266.0958 A 11:50:07 Magnet Current, Imag = 266.0958 A 11:50:08 Power Supply 1 Current, Ips = 266.1118 A 11:50:08 Magnet Current, Imag = 266.1118 A 11:50:09 Power Supply 1 Current, Ips = 266.0696 A 11:50:09 Magnet Current, Imag = 266.0696 A 11:50:09 Magnet Current Measurement: Imag = 266.0934 +- 1.515702E-02 A 11:50:12 Wire moved to X = 1.5 cm 11:50:16 Wire moved by DX = 1 cm 11:50:26 X0 = 2 cm, dx = 1 cm, VT = 1.102214E-02 VS 11:50:28 Wire moved to X = 2.5 cm 11:50:32 Wire moved by DX = -1 cm 11:50:42 X0 = 2 cm, dx = -1 cm, VT = -1.109435E-02 VS 11:50:43 Wire moved to X = 1.5 cm 11:50:48 Wire moved by DX = 1 cm 11:50:58 X0 = 2 cm, dx = 1 cm, VT = 1.105758E-02 VS 11:50:59 Wire moved to X = 2.5 cm 11:51:03 Wire moved by DX = -1 cm 11:51:13 X0 = 2 cm, dx = -1 cm, VT = -1.110063E-02 VS 11:51:15 Wire moved to X = 1.5 cm 11:51:19 Wire moved by DX = 1 cm 11:51:29 X0 = 2 cm, dx = 1 cm, VT = 1.102054E-02 VS 11:51:30 Wire moved to X = 2.5 cm 11:51:35 Wire moved by DX = -1 cm 11:51:45 X0 = 2 cm, dx = -1 cm, VT = -1.106997E-02 VS 11:51:46 Wire moved to X = 1.5 cm 11:51:51 Wire moved by DX = 1 cm 11:52:01 X0 = 2 cm, dx = 1 cm, VT = 1.102711E-02 VS 11:52:02 Wire moved to X = 2.5 cm 11:52:06 Wire moved by DX = -1 cm 11:52:16 X0 = 2 cm, dx = -1 cm, VT = -1.106861E-02 VS 11:52:16 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 2 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.105762E-02 +- 1.332293E-05 VS (= Tm^2) 11:52:18 Power Supply 1 Current, Ips = 266.1136 A 11:52:18 Magnet Current, Imag = 266.1136 A 11:52:19 Power Supply 1 Current, Ips = 266.0752 A 11:52:19 Magnet Current, Imag = 266.0752 A 11:52:20 Power Supply 1 Current, Ips = 266.0972 A 11:52:20 Magnet Current, Imag = 266.0972 A 11:52:22 Power Supply 1 Current, Ips = 266.0126 A 11:52:22 Magnet Current, Imag = 266.0126 A 11:52:22 Magnet Current Measurement: Imag = 266.0747 +- 3.832729E-02 A 11:52:24 Wire moved to X = 2 cm 11:52:29 Wire moved by DX = 1 cm 11:52:39 X0 = 2.5 cm, dx = 1 cm, VT = 1.107893E-02 VS 11:52:40 Wire moved to X = 3 cm 11:52:45 Wire moved by DX = -1 cm 11:52:54 X0 = 2.5 cm, dx = -1 cm, VT = -1.105301E-02 VS 11:52:56 Wire moved to X = 2 cm 11:53:00 Wire moved by DX = 1 cm 11:53:10 X0 = 2.5 cm, dx = 1 cm, VT = 1.109888E-02 VS 11:53:12 Wire moved to X = 3 cm 11:53:17 Wire moved by DX = -1 cm 11:53:27 X0 = 2.5 cm, dx = -1 cm, VT = -1.106323E-02 VS 11:53:29 Wire moved to X = 2 cm 11:53:33 Wire moved by DX = 1 cm 11:53:43 X0 = 2.5 cm, dx = 1 cm, VT = 1.106232E-02 VS 11:53:44 Wire moved to X = 3 cm 11:53:49 Wire moved by DX = -1 cm 11:53:59 X0 = 2.5 cm, dx = -1 cm, VT = -1.108956E-02 VS 11:54:00 Wire moved to X = 2 cm 11:54:05 Wire moved by DX = 1 cm 11:54:15 X0 = 2.5 cm, dx = 1 cm, VT = 1.107314E-02 VS 11:54:16 Wire moved to X = 3 cm 11:54:21 Wire moved by DX = -1 cm 11:54:30 X0 = 2.5 cm, dx = -1 cm, VT = -1.113021E-02 VS 11:54:30 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 2.5 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.108116E-02 +- 1.302906E-05 VS (= Tm^2) 11:54:33 Power Supply 1 Current, Ips = 266.0874 A 11:54:33 Magnet Current, Imag = 266.0874 A 11:54:34 Power Supply 1 Current, Ips = 266.096 A 11:54:34 Magnet Current, Imag = 266.096 A 11:54:35 Power Supply 1 Current, Ips = 266.0958 A 11:54:35 Magnet Current, Imag = 266.0958 A 11:54:37 Power Supply 1 Current, Ips = 266.1306 A 11:54:37 Magnet Current, Imag = 266.1306 A 11:54:37 Magnet Current Measurement: Imag = 266.1024 +- 1.660857E-02 A 11:54:39 Wire moved to X = 2.5 cm 11:54:44 Wire moved by DX = 1 cm 11:54:53 X0 = 3 cm, dx = 1 cm, VT = 1.114996E-02 VS 11:54:55 Wire moved to X = 3.5 cm 11:54:59 Wire moved by DX = -1 cm 11:55:09 X0 = 3 cm, dx = -1 cm, VT = -1.118278E-02 VS 11:55:10 Wire moved to X = 2.5 cm 11:55:15 Wire moved by DX = 1 cm 11:55:25 X0 = 3 cm, dx = 1 cm, VT = 1.113484E-02 VS 11:55:26 Wire moved to X = 3.5 cm 11:55:31 Wire moved by DX = -1 cm 11:55:40 X0 = 3 cm, dx = -1 cm, VT = -1.117294E-02 VS 11:55:42 Wire moved to X = 2.5 cm 11:55:46 Wire moved by DX = 1 cm 11:55:56 X0 = 3 cm, dx = 1 cm, VT = 1.114671E-02 VS 11:55:58 Wire moved to X = 3.5 cm 11:56:02 Wire moved by DX = -1 cm 11:56:12 X0 = 3 cm, dx = -1 cm, VT = -1.119609E-02 VS 11:56:13 Wire moved to X = 2.5 cm 11:56:18 Wire moved by DX = 1 cm 11:56:28 X0 = 3 cm, dx = 1 cm, VT = 1.115994E-02 VS 11:56:29 Wire moved to X = 3.5 cm 11:56:34 Wire moved by DX = -1 cm 11:56:43 X0 = 3 cm, dx = -1 cm, VT = -1.114875E-02 VS 11:56:43 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 3 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = .0111615 +- 7.597814E-06 VS (= Tm^2) 11:56:45 Power Supply 1 Current, Ips = 266.1052 A 11:56:45 Magnet Current, Imag = 266.1052 A 11:56:46 Power Supply 1 Current, Ips = 266.098 A 11:56:46 Magnet Current, Imag = 266.098 A 11:56:47 Power Supply 1 Current, Ips = 266.0912 A 11:56:47 Magnet Current, Imag = 266.0912 A 11:56:49 Power Supply 1 Current, Ips = 266.0804 A 11:56:49 Magnet Current, Imag = 266.0804 A 11:56:49 Magnet Current Measurement: Imag = 266.0937 +- 9.127205E-03 A 11:56:51 Wire moved to X = 3 cm 11:56:56 Wire moved by DX = 1 cm 11:57:06 X0 = 3.5 cm, dx = 1 cm, VT = 1.125639E-02 VS 11:57:07 Wire moved to X = 4 cm 11:57:12 Wire moved by DX = -1 cm 11:57:21 X0 = 3.5 cm, dx = -1 cm, VT = -1.127682E-02 VS 11:57:23 Wire moved to X = 3 cm 11:57:27 Wire moved by DX = 1 cm 11:57:37 X0 = 3.5 cm, dx = 1 cm, VT = 1.125919E-02 VS 11:57:39 Wire moved to X = 4 cm 11:57:43 Wire moved by DX = -1 cm 11:57:53 X0 = 3.5 cm, dx = -1 cm, VT = -1.133063E-02 VS 11:57:54 Wire moved to X = 3 cm 11:57:59 Wire moved by DX = 1 cm 11:58:09 X0 = 3.5 cm, dx = 1 cm, VT = 1.128621E-02 VS 11:58:10 Wire moved to X = 4 cm 11:58:15 Wire moved by DX = -1 cm 11:58:24 X0 = 3.5 cm, dx = -1 cm, VT = -1.127646E-02 VS 11:58:26 Wire moved to X = 3 cm 11:58:30 Wire moved by DX = 1 cm 11:58:41 X0 = 3.5 cm, dx = 1 cm, VT = 1.125205E-02 VS 11:58:42 Wire moved to X = 4 cm 11:58:47 Wire moved by DX = -1 cm 11:58:57 X0 = 3.5 cm, dx = -1 cm, VT = -1.132637E-02 VS 11:58:57 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 3.5 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.128302E-02 +- 1.063023E-05 VS (= Tm^2) 11:58:59 Power Supply 1 Current, Ips = 266.108 A 11:58:59 Magnet Current, Imag = 266.108 A 11:59:00 Power Supply 1 Current, Ips = 266.0766 A 11:59:00 Magnet Current, Imag = 266.0766 A 11:59:01 Power Supply 1 Current, Ips = 266.0954 A 11:59:01 Magnet Current, Imag = 266.0954 A 11:59:03 Power Supply 1 Current, Ips = 266.093 A 11:59:03 Magnet Current, Imag = 266.093 A 11:59:03 Magnet Current Measurement: Imag = 266.0932 +- 1.117529E-02 A 11:59:05 Wire moved to X = 3.5 cm 11:59:10 Wire moved by DX = 1 cm 11:59:19 X0 = 4 cm, dx = 1 cm, VT = 1.121642E-02 VS 11:59:21 Wire moved to X = 4.5 cm 11:59:25 Wire moved by DX = -1 cm 11:59:35 X0 = 4 cm, dx = -1 cm, VT = -1.128412E-02 VS 11:59:37 Wire moved to X = 3.5 cm 11:59:41 Wire moved by DX = 1 cm 11:59:51 X0 = 4 cm, dx = 1 cm, VT = 1.122941E-02 VS 11:59:53 Wire moved to X = 4.5 cm 11:59:57 Wire moved by DX = -1 cm 12:00:07 X0 = 4 cm, dx = -1 cm, VT = -1.127055E-02 VS 12:00:08 Wire moved to X = 3.5 cm 12:00:13 Wire moved by DX = 1 cm 12:00:23 X0 = 4 cm, dx = 1 cm, VT = 1.120046E-02 VS 12:00:24 Wire moved to X = 4.5 cm 12:00:28 Wire moved by DX = -1 cm 12:00:38 X0 = 4 cm, dx = -1 cm, VT = -1.120874E-02 VS 12:00:40 Wire moved to X = 3.5 cm 12:00:44 Wire moved by DX = 1 cm 12:00:54 X0 = 4 cm, dx = 1 cm, VT = 1.122846E-02 VS 12:00:56 Wire moved to X = 4.5 cm 12:01:00 Wire moved by DX = -1 cm 12:01:10 X0 = 4 cm, dx = -1 cm, VT = -1.125677E-02 VS 12:01:10 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 4 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.123687E-02 +- 1.888048E-05 VS (= Tm^2) 12:01:20 Wire moved to X = 0 cm