SLAC Magnetic Measurements
Date: 07-31-1996
Time: 13:41:10

Project: PEP2INJ
Magnet Type: DIPOLE
Magnet Name (Serial #): BFIX6421
Bar Code Number: SN001
Test Stand: MAGLAB #4
Measurement System: STRETCHED WIRE
Operator: pdr
Run Number: 4
Comment: Measure Int Bdl @ 100 amps

Test Currents
   100.0

13:41:12  Magnet Current Ramping to  100  A...

13:41:48  Magnet Current Measurement...
13:41:49  Power Supply  3  Current, Ips =  99.877  A
13:41:49  Magnet Current, Imag =  99.877  A
13:41:51  Power Supply  3  Current, Ips =  99.8106  A
13:41:51  Magnet Current, Imag =  99.8106  A
13:41:52  Power Supply  3  Current, Ips =  99.8546  A
13:41:52  Magnet Current, Imag =  99.8546  A
13:41:53  Power Supply  3  Current, Ips =  99.8824  A
13:41:54  Magnet Current, Imag =  99.8824  A
13:41:54  Magnet Current Measurement:
          Imag =  99.85614  +-  2.828846E-02  A

13:41:54  Integrated Voltage Measurement...
13:41:56  Wire moved to X = -.5  cm
13:42:01  Wire moved by DX =  1  cm
13:42:08  X0 =  0  cm, dx =  1  cm, VT =  1.447852E-02  VS
13:42:09  Wire moved to X =  .5  cm
13:42:14  Wire moved by DX = -1  cm
13:42:21  X0 =  0  cm, dx = -1  cm, VT = -.0145544  VS
13:42:22  Wire moved to X = -.5  cm
13:42:27  Wire moved by DX =  1  cm
13:42:34  X0 =  0  cm, dx =  1  cm, VT =  1.446474E-02  VS
13:42:35  Wire moved to X =  .5  cm
13:42:40  Wire moved by DX = -1  cm
13:42:47  X0 =  0  cm, dx = -1  cm, VT = -1.457136E-02  VS
13:42:48  Wire moved to X = -.5  cm
13:42:52  Wire moved by DX =  1  cm
13:43:00  X0 =  0  cm, dx =  1  cm, VT =  1.451278E-02  VS
13:43:01  Wire moved to X =  .5  cm
13:43:06  Wire moved by DX = -1  cm
13:43:13  X0 =  0  cm, dx = -1  cm, VT = -1.455305E-02  VS
13:43:14  Wire moved to X = -.5  cm
13:43:19  Wire moved by DX =  1  cm
13:43:26  X0 =  0  cm, dx =  1  cm, VT =  1.450337E-02  VS
13:43:27  Wire moved to X =  .5  cm
13:43:32  Wire moved by DX = -1  cm
13:43:39  X0 =  0  cm, dx = -1  cm, VT = -1.455601E-02  VS
13:43:39  Integrated Voltage Measurement:
          Center Of Wire Motion, X0 =  0  cm
          Distance Wire Moved, Delta X =  1  cm
          # Measurements For Average, Nmeas =  4 
          Integrated Voltage, VT =  1.452428E-02  +-  7.135584E-06  VS (= Tm^2)
13:43:39  The integrated field strength is BL =  .1452428  +-  7.135584E-05  Tm
13:43:41  Wire moved to X =  0  cm