SLAC Magnetic Measurements
Date: 07-31-1996
Time: 13:21:22

Project: PEP2INJ
Magnet Type: DIPOLE
Magnet Name (Serial #): BFIX6421
Bar Code Number: SN001
Test Stand: MAGLAB #4
Measurement System: STRETCHED WIRE
Operator: pdr
Run Number: 3
Comment: Standardize and measure Int Bdl @ 100 amps

Standardization Currents
 3  cycles, 0 to  100  to 0 A

Test Currents
   100.0

13:23:07  Magnet Current Ramping to  100  A...

13:24:32  Magnet Current Ramping to  2  A...

13:25:57  Magnet Current Ramping to  100  A...

13:27:22  Magnet Current Ramping to  2  A...

13:28:47  Magnet Current Ramping to  100  A...

13:30:12  Magnet Current Ramping to  2  A...

13:31:37  Magnet Current Ramping to  100  A...

13:33:03  Magnet Current Measurement...
13:33:05  Power Supply  3  Current, Ips =  99.8774  A
13:33:05  Magnet Current, Imag =  99.8774  A
13:33:06  Power Supply  3  Current, Ips =  99.82021  A
13:33:06  Magnet Current, Imag =  99.82021  A
13:33:07  Power Supply  3  Current, Ips =  99.8104  A
13:33:07  Magnet Current, Imag =  99.8104  A
13:33:09  Power Supply  3  Current, Ips =  99.874  A
13:33:09  Magnet Current, Imag =  99.874  A
13:33:09  Magnet Current Measurement:
          Imag =  99.8455  +-  3.042112E-02  A

13:33:09  Integrated Voltage Measurement...
13:33:11  Wire moved to X = -.5  cm
13:33:16  Wire moved by DX =  1  cm
13:33:23  X0 =  0  cm, dx =  1  cm, VT =  6.672692E-05  VS
13:33:25  Wire moved to X =  .5  cm
13:33:30  Wire moved by DX = -1  cm
13:33:37  X0 =  0  cm, dx = -1  cm, VT =  9.12347E-07  VS
13:33:40  Wire moved to X = -.5  cm
13:33:44  Wire moved by DX =  1  cm
13:33:51  X0 =  0  cm, dx =  1  cm, VT = -4.963716E-06  VS
13:33:54  Wire moved to X =  .5  cm
13:33:58  Wire moved by DX = -1  cm
13:34:05  X0 =  0  cm, dx = -1  cm, VT =  7.198963E-06  VS
13:34:08  Wire moved to X = -.5  cm
13:34:12  Wire moved by DX =  1  cm
13:34:19  X0 =  0  cm, dx =  1  cm, VT =  1.122311E-05  VS
13:34:22  Wire moved to X =  .5  cm
13:34:26  Wire moved by DX = -1  cm
13:34:33  X0 =  0  cm, dx = -1  cm, VT =  2.12534E-05  VS
13:34:36  Wire moved to X = -.5  cm
13:34:40  Wire moved by DX =  1  cm
13:34:47  X0 =  0  cm, dx =  1  cm, VT =  1.515535E-05  VS
13:34:50  Wire moved to X =  .5  cm
13:34:54  Wire moved by DX = -1  cm
13:35:01  X0 =  0  cm, dx = -1  cm, VT =  3.890703E-05  VS
13:35:02  Integrated Voltage Measurement:
          Center Of Wire Motion, X0 =  0  cm
          Distance Wire Moved, Delta X =  1  cm
          # Measurements For Average, Nmeas =  4 
          Integrated Voltage, VT =  2.48374E-06  +-  1.775798E-05  VS (= Tm^2)
13:35:02  The integrated field strength is BL =  2.48374E-05  +-  1.775798E-04  Tm
13:35:03  Wire moved to X =  0  cm