SLAC Magnetic Measurements Date: 10-19-1995 Time: 10:35:54 Project: NITSIT Magnet Name (Serial #): CORPROTO Bar Code Number: 000 Test Stand: 5 Measurement Coil: WIRE SYSTEM Operator: zw Run Number: 2 Comment: Hysteresis loop to +-6 A Test Currents 0.0 1.0 2.0 3.0 4.0 5.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0 -1.0 -2.0 -3.0 -4.0 -5.0 -6.0 -5.0 -4.0 -3.0 -2.0 -1.0 0.0 10:36:53 Magnet Current, Imag = 8.27235E-03 A 10:36:53 Magnet Current Ramping to 0 A... 10:37:06 Magnet Current, Imag = .008272 A 10:37:10 Magnet Current, Imag = 8.271275E-03 A 10:37:12 Magnet Current, Imag = 8.265675E-03 A 10:37:13 Magnet Current, Imag = 8.274225E-03 A 10:37:15 Magnet Current, Imag = 8.276325E-03 A 10:37:15 Magnet Current Measurement: Imag = 8.271875E-03 +- 4.003745E-06 A 10:37:17 Wire moved to X = -.5 cm 10:37:22 Wire moved by DX = 1 cm 10:37:29 X0 = 0 cm, dx = 1 cm, VT = -4.746023E-06 VS 10:37:30 Wire moved to X = .5 cm 10:37:35 Wire moved by DX = -1 cm 10:37:41 X0 = 0 cm, dx = -1 cm, VT = 2.830748E-05 VS 10:37:42 Wire moved to X = -.5 cm 10:37:47 Wire moved by DX = 1 cm 10:37:54 X0 = 0 cm, dx = 1 cm, VT = -1.937644E-06 VS 10:37:55 Wire moved to X = .5 cm 10:38:00 Wire moved by DX = -1 cm 10:38:06 X0 = 0 cm, dx = -1 cm, VT = 2.459945E-05 VS 10:38:07 Wire moved to X = -.5 cm 10:38:12 Wire moved by DX = 1 cm 10:38:19 X0 = 0 cm, dx = 1 cm, VT = -2.649224E-06 VS 10:38:20 Wire moved to X = .5 cm 10:38:25 Wire moved by DX = -1 cm 10:38:31 X0 = 0 cm, dx = -1 cm, VT = 2.387573E-05 VS 10:38:32 Wire moved to X = -.5 cm 10:38:37 Wire moved by DX = 1 cm 10:38:43 X0 = 0 cm, dx = 1 cm, VT = -6.269092E-06 VS 10:38:45 Wire moved to X = .5 cm 10:38:50 Wire moved by DX = -1 cm 10:38:56 X0 = 0 cm, dx = -1 cm, VT = 2.050924E-05 VS 10:38:56 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = -1.411174E-05 +- 1.395225E-06 VS (= Tm^2) 10:38:58 Wire moved to X = 0 cm 10:39:00 Magnet Current, Imag = 8.274149E-03 A 10:39:00 Magnet Current Ramping to 1 A... 10:39:17 Magnet Current, Imag = 1.026092 A 10:39:20 Magnet Current, Imag = 1.026083 A 10:39:21 Magnet Current, Imag = 1.026085 A 10:39:22 Magnet Current, Imag = 1.026085 A 10:39:23 Magnet Current, Imag = 1.026085 A 10:39:23 Magnet Current Measurement: Imag = 1.026084 +- 1.087683E-06 A 10:39:26 Wire moved to X = -.5 cm 10:39:31 Wire moved by DX = 1 cm 10:39:37 X0 = 0 cm, dx = 1 cm, VT = -2.11685E-04 VS 10:39:38 Wire moved to X = .5 cm 10:39:43 Wire moved by DX = -1 cm 10:39:49 X0 = 0 cm, dx = -1 cm, VT = 2.144464E-04 VS 10:39:50 Wire moved to X = -.5 cm 10:39:55 Wire moved by DX = 1 cm 10:40:02 X0 = 0 cm, dx = 1 cm, VT = -2.166753E-04 VS 10:40:03 Wire moved to X = .5 cm 10:40:08 Wire moved by DX = -1 cm 10:40:14 X0 = 0 cm, dx = -1 cm, VT = 2.16473E-04 VS 10:40:15 Wire moved to X = -.5 cm 10:40:20 Wire moved by DX = 1 cm 10:40:26 X0 = 0 cm, dx = 1 cm, VT = -2.145415E-04 VS 10:40:28 Wire moved to X = .5 cm 10:40:33 Wire moved by DX = -1 cm 10:40:39 X0 = 0 cm, dx = -1 cm, VT = 2.154276E-04 VS 10:40:40 Wire moved to X = -.5 cm 10:40:45 Wire moved by DX = 1 cm 10:40:51 X0 = 0 cm, dx = 1 cm, VT = -2.113633E-04 VS 10:40:53 Wire moved to X = .5 cm 10:40:58 Wire moved by DX = -1 cm 10:41:04 X0 = 0 cm, dx = -1 cm, VT = 2.179883E-04 VS 10:41:04 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = -2.14825E-04 +- 1.245213E-06 VS (= Tm^2) 10:41:06 Wire moved to X = 0 cm 10:41:07 Magnet Current, Imag = 1.026083 A 10:41:08 Magnet Current Ramping to 2 A... 10:41:23 Magnet Current, Imag = 2.042948 A 10:41:26 Magnet Current, Imag = 2.042943 A 10:41:27 Magnet Current, Imag = 2.042945 A 10:41:28 Magnet Current, Imag = 2.042948 A 10:41:30 Magnet Current, Imag = 2.04295 A 10:41:30 Magnet Current Measurement: Imag = 2.042946 +- 2.775299E-06 A 10:41:32 Wire moved to X = -.5 cm 10:41:37 Wire moved by DX = 1 cm 10:41:43 X0 = 0 cm, dx = 1 cm, VT = -4.198093E-04 VS 10:41:44 Wire moved to X = .5 cm 10:41:49 Wire moved by DX = -1 cm 10:41:56 X0 = 0 cm, dx = -1 cm, VT = 4.22937E-04 VS 10:41:57 Wire moved to X = -.5 cm 10:42:02 Wire moved by DX = 1 cm 10:42:08 X0 = 0 cm, dx = 1 cm, VT = -4.113037E-04 VS 10:42:09 Wire moved to X = .5 cm 10:42:14 Wire moved by DX = -1 cm 10:42:21 X0 = 0 cm, dx = -1 cm, VT = 4.31454E-04 VS 10:42:22 Wire moved to X = -.5 cm 10:42:27 Wire moved by DX = 1 cm 10:42:33 X0 = 0 cm, dx = 1 cm, VT = -4.113668E-04 VS 10:42:34 Wire moved to X = .5 cm 10:42:39 Wire moved by DX = -1 cm 10:42:45 X0 = 0 cm, dx = -1 cm, VT = 4.273114E-04 VS 10:42:47 Wire moved to X = -.5 cm 10:42:52 Wire moved by DX = 1 cm 10:42:58 X0 = 0 cm, dx = 1 cm, VT = -4.121129E-04 VS 10:42:59 Wire moved to X = .5 cm 10:43:04 Wire moved by DX = -1 cm 10:43:10 X0 = 0 cm, dx = -1 cm, VT = 4.336505E-04 VS 10:43:10 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = -4.212432E-04 +- 1.259523E-06 VS (= Tm^2) 10:43:13 Wire moved to X = 0 cm 10:43:14 Magnet Current, Imag = 2.042915 A 10:43:14 Magnet Current Ramping to 3 A... 10:43:30 Magnet Current, Imag = 3.06065 A 10:43:33 Magnet Current, Imag = 3.060647 A 10:43:34 Magnet Current, Imag = 3.060645 A 10:43:35 Magnet Current, Imag = 3.060647 A 10:43:37 Magnet Current, Imag = 3.06065 A 10:43:37 Magnet Current Measurement: Imag = 3.060647 +- 1.772174E-06 A 10:43:39 Wire moved to X = -.5 cm 10:43:44 Wire moved by DX = 1 cm 10:43:50 X0 = 0 cm, dx = 1 cm, VT = -6.155216E-04 VS 10:43:51 Wire moved to X = .5 cm 10:43:56 Wire moved by DX = -1 cm 10:44:03 X0 = 0 cm, dx = -1 cm, VT = 6.460504E-04 VS 10:44:04 Wire moved to X = -.5 cm 10:44:09 Wire moved by DX = 1 cm 10:44:15 X0 = 0 cm, dx = 1 cm, VT = -6.203114E-04 VS 10:44:16 Wire moved to X = .5 cm 10:44:21 Wire moved by DX = -1 cm 10:44:28 X0 = 0 cm, dx = -1 cm, VT = 6.453554E-04 VS 10:44:29 Wire moved to X = -.5 cm 10:44:34 Wire moved by DX = 1 cm 10:44:40 X0 = 0 cm, dx = 1 cm, VT = -6.145065E-04 VS 10:44:41 Wire moved to X = .5 cm 10:44:46 Wire moved by DX = -1 cm 10:44:53 X0 = 0 cm, dx = -1 cm, VT = 6.456203E-04 VS 10:44:54 Wire moved to X = -.5 cm 10:44:59 Wire moved by DX = 1 cm 10:45:05 X0 = 0 cm, dx = 1 cm, VT = -6.222419E-04 VS 10:45:06 Wire moved to X = .5 cm 10:45:12 Wire moved by DX = -1 cm 10:45:18 X0 = 0 cm, dx = -1 cm, VT = 6.410064E-04 VS 10:45:18 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = -6.313268E-04 +- 1.030417E-06 VS (= Tm^2) 10:45:20 Wire moved to X = 0 cm 10:45:21 Magnet Current, Imag = 3.06059 A 10:45:21 Magnet Current Ramping to 4 A... 10:45:37 Magnet Current, Imag = 4.077232 A 10:45:40 Magnet Current, Imag = 4.07723 A 10:45:41 Magnet Current, Imag = 4.077232 A 10:45:42 Magnet Current, Imag = 4.07723 A 10:45:44 Magnet Current, Imag = 4.077225 A 10:45:44 Magnet Current Measurement: Imag = 4.077229 +- 2.800784E-06 A 10:45:46 Wire moved to X = -.5 cm 10:45:51 Wire moved by DX = 1 cm 10:45:57 X0 = 0 cm, dx = 1 cm, VT = -8.313003E-04 VS 10:45:59 Wire moved to X = .5 cm 10:46:04 Wire moved by DX = -1 cm 10:46:10 X0 = 0 cm, dx = -1 cm, VT = 8.500778E-04 VS 10:46:11 Wire moved to X = -.5 cm 10:46:16 Wire moved by DX = 1 cm 10:46:22 X0 = 0 cm, dx = 1 cm, VT = -8.318374E-04 VS 10:46:24 Wire moved to X = .5 cm 10:46:29 Wire moved by DX = -1 cm 10:46:35 X0 = 0 cm, dx = -1 cm, VT = 8.487075E-04 VS 10:46:36 Wire moved to X = -.5 cm 10:46:41 Wire moved by DX = 1 cm 10:46:48 X0 = 0 cm, dx = 1 cm, VT = -8.301197E-04 VS 10:46:49 Wire moved to X = .5 cm 10:46:54 Wire moved by DX = -1 cm 10:47:00 X0 = 0 cm, dx = -1 cm, VT = 8.500259E-04 VS 10:47:01 Wire moved to X = -.5 cm 10:47:06 Wire moved by DX = 1 cm 10:47:13 X0 = 0 cm, dx = 1 cm, VT = -8.323157E-04 VS 10:47:14 Wire moved to X = .5 cm 10:47:19 Wire moved by DX = -1 cm 10:47:25 X0 = 0 cm, dx = -1 cm, VT = 8.528403E-04 VS 10:47:25 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = -8.409031E-04 +- 9.922693E-07 VS (= Tm^2) 10:47:27 Wire moved to X = 0 cm 10:47:29 Magnet Current, Imag = 4.077115 A 10:47:29 Magnet Current Ramping to 5 A... 10:47:45 Magnet Current, Imag = 5.094785 A 10:47:47 Magnet Current, Imag = 5.094767 A 10:47:49 Magnet Current, Imag = 5.094762 A 10:47:50 Magnet Current, Imag = 5.094762 A 10:47:51 Magnet Current, Imag = 5.094755 A 10:47:51 Magnet Current Measurement: Imag = 5.094762 +- 4.258292E-06 A 10:47:53 Wire moved to X = -.5 cm 10:47:58 Wire moved by DX = 1 cm 10:48:05 X0 = 0 cm, dx = 1 cm, VT = -1.040876E-03 VS 10:48:06 Wire moved to X = .5 cm 10:48:11 Wire moved by DX = -1 cm 10:48:17 X0 = 0 cm, dx = -1 cm, VT = 1.054696E-03 VS 10:48:19 Wire moved to X = -.5 cm 10:48:24 Wire moved by DX = 1 cm 10:48:30 X0 = 0 cm, dx = 1 cm, VT = -1.04318E-03 VS 10:48:31 Wire moved to X = .5 cm 10:48:36 Wire moved by DX = -1 cm 10:48:42 X0 = 0 cm, dx = -1 cm, VT = 1.061156E-03 VS 10:48:44 Wire moved to X = -.5 cm 10:48:49 Wire moved by DX = 1 cm 10:48:55 X0 = 0 cm, dx = 1 cm, VT = -1.040835E-03 VS 10:48:56 Wire moved to X = .5 cm 10:49:01 Wire moved by DX = -1 cm 10:49:07 X0 = 0 cm, dx = -1 cm, VT = 1.059106E-03 VS 10:49:08 Wire moved to X = -.5 cm 10:49:13 Wire moved by DX = 1 cm 10:49:20 X0 = 0 cm, dx = 1 cm, VT = -1.040621E-03 VS 10:49:21 Wire moved to X = .5 cm 10:49:26 Wire moved by DX = -1 cm 10:49:32 X0 = 0 cm, dx = -1 cm, VT = 1.059434E-03 VS 10:49:32 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = -1.049988E-03 +- 1.549438E-06 VS (= Tm^2) 10:49:35 Wire moved to X = 0 cm 10:49:36 Magnet Current, Imag = 5.094603 A 10:49:36 Magnet Current Ramping to 6 A... 10:49:52 Magnet Current, Imag = 6.111372 A 10:49:54 Magnet Current, Imag = 6.111365 A 10:49:56 Magnet Current, Imag = 6.111362 A 10:49:57 Magnet Current, Imag = 6.111355 A 10:49:58 Magnet Current, Imag = 6.11135 A 10:49:58 Magnet Current Measurement: Imag = 6.111358 +- 5.922195E-06 A 10:50:01 Wire moved to X = -.5 cm 10:50:06 Wire moved by DX = 1 cm 10:50:12 X0 = 0 cm, dx = 1 cm, VT = -1.252848E-03 VS 10:50:13 Wire moved to X = .5 cm 10:50:18 Wire moved by DX = -1 cm 10:50:24 X0 = 0 cm, dx = -1 cm, VT = 1.268587E-03 VS 10:50:26 Wire moved to X = -.5 cm 10:50:31 Wire moved by DX = 1 cm 10:50:37 X0 = 0 cm, dx = 1 cm, VT = -1.24651E-03 VS 10:50:38 Wire moved to X = .5 cm 10:50:43 Wire moved by DX = -1 cm 10:50:49 X0 = 0 cm, dx = -1 cm, VT = 1.270229E-03 VS 10:50:51 Wire moved to X = -.5 cm 10:50:56 Wire moved by DX = 1 cm 10:51:02 X0 = 0 cm, dx = 1 cm, VT = -1.254424E-03 VS 10:51:03 Wire moved to X = .5 cm 10:51:08 Wire moved by DX = -1 cm 10:51:14 X0 = 0 cm, dx = -1 cm, VT = 1.268342E-03 VS 10:51:16 Wire moved to X = -.5 cm 10:51:21 Wire moved by DX = 1 cm 10:51:27 X0 = 0 cm, dx = 1 cm, VT = -1.25292E-03 VS 10:51:28 Wire moved to X = .5 cm 10:51:33 Wire moved by DX = -1 cm 10:51:39 X0 = 0 cm, dx = -1 cm, VT = 1.266051E-03 VS 10:51:39 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = -1.259989E-03 +- 1.156553E-06 VS (= Tm^2) 10:51:42 Wire moved to X = 0 cm 10:51:43 Magnet Current, Imag = 6.111153 A 10:51:43 Magnet Current Ramping to 5 A... 10:51:59 Magnet Current, Imag = 5.094352 A 10:52:02 Magnet Current, Imag = 5.094357 A 10:52:03 Magnet Current, Imag = 5.094362 A 10:52:04 Magnet Current, Imag = 5.09436 A 10:52:05 Magnet Current, Imag = 5.094367 A 10:52:05 Magnet Current Measurement: Imag = 5.094361 +- 3.544347E-06 A 10:52:08 Wire moved to X = -.5 cm 10:52:13 Wire moved by DX = 1 cm 10:52:19 X0 = 0 cm, dx = 1 cm, VT = -1.058086E-03 VS 10:52:20 Wire moved to X = .5 cm 10:52:25 Wire moved by DX = -1 cm 10:52:31 X0 = 0 cm, dx = -1 cm, VT = 1.065024E-03 VS 10:52:33 Wire moved to X = -.5 cm 10:52:38 Wire moved by DX = 1 cm 10:52:44 X0 = 0 cm, dx = 1 cm, VT = -1.061553E-03 VS 10:52:45 Wire moved to X = .5 cm 10:52:50 Wire moved by DX = -1 cm 10:52:56 X0 = 0 cm, dx = -1 cm, VT = 1.067285E-03 VS 10:52:58 Wire moved to X = -.5 cm 10:53:03 Wire moved by DX = 1 cm 10:53:09 X0 = 0 cm, dx = 1 cm, VT = -1.059327E-03 VS 10:53:10 Wire moved to X = .5 cm 10:53:15 Wire moved by DX = -1 cm 10:53:21 X0 = 0 cm, dx = -1 cm, VT = 1.06406E-03 VS 10:53:23 Wire moved to X = -.5 cm 10:53:28 Wire moved by DX = 1 cm 10:53:34 X0 = 0 cm, dx = 1 cm, VT = -1.062397E-03 VS 10:53:35 Wire moved to X = .5 cm 10:53:40 Wire moved by DX = -1 cm 10:53:46 X0 = 0 cm, dx = -1 cm, VT = 1.06652E-03 VS 10:53:46 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = -1.063032E-03 +- 1.408179E-06 VS (= Tm^2) 10:53:49 Wire moved to X = 0 cm 10:53:50 Magnet Current, Imag = 5.094475 A 10:53:50 Magnet Current Ramping to 4 A... 10:54:06 Magnet Current, Imag = 4.076842 A 10:54:09 Magnet Current, Imag = 4.07685 A 10:54:10 Magnet Current, Imag = 4.076848 A 10:54:11 Magnet Current, Imag = 4.07685 A 10:54:12 Magnet Current, Imag = 4.07685 A 10:54:12 Magnet Current Measurement: Imag = 4.076849 +- 1.039243E-06 A 10:54:15 Wire moved to X = -.5 cm 10:54:20 Wire moved by DX = 1 cm 10:54:26 X0 = 0 cm, dx = 1 cm, VT = -8.555951E-04 VS 10:54:27 Wire moved to X = .5 cm 10:54:32 Wire moved by DX = -1 cm 10:54:38 X0 = 0 cm, dx = -1 cm, VT = 8.600958E-04 VS 10:54:40 Wire moved to X = -.5 cm 10:54:45 Wire moved by DX = 1 cm 10:54:51 X0 = 0 cm, dx = 1 cm, VT = -8.566687E-04 VS 10:54:52 Wire moved to X = .5 cm 10:54:57 Wire moved by DX = -1 cm 10:55:03 X0 = 0 cm, dx = -1 cm, VT = 8.626477E-04 VS 10:55:05 Wire moved to X = -.5 cm 10:55:10 Wire moved by DX = 1 cm 10:55:16 X0 = 0 cm, dx = 1 cm, VT = -8.536035E-04 VS 10:55:17 Wire moved to X = .5 cm 10:55:22 Wire moved by DX = -1 cm 10:55:28 X0 = 0 cm, dx = -1 cm, VT = 8.651048E-04 VS 10:55:30 Wire moved to X = -.5 cm 10:55:35 Wire moved by DX = 1 cm 10:55:41 X0 = 0 cm, dx = 1 cm, VT = -8.520519E-04 VS 10:55:42 Wire moved to X = .5 cm 10:55:47 Wire moved by DX = -1 cm 10:55:53 X0 = 0 cm, dx = -1 cm, VT = 8.624097E-04 VS 10:55:53 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = -8.585221E-04 +- 1.013451E-06 VS (= Tm^2) 10:55:56 Wire moved to X = 0 cm 10:55:57 Magnet Current, Imag = 4.07694 A 10:55:57 Magnet Current Ramping to 3 A... 10:56:13 Magnet Current, Imag = 3.060335 A 10:56:16 Magnet Current, Imag = 3.060345 A 10:56:17 Magnet Current, Imag = 3.060345 A 10:56:18 Magnet Current, Imag = 3.060345 A 10:56:19 Magnet Current, Imag = 3.060342 A 10:56:19 Magnet Current Measurement: Imag = 3.060344 +- 1.137184E-06 A 10:56:22 Wire moved to X = -.5 cm 10:56:27 Wire moved by DX = 1 cm 10:56:33 X0 = 0 cm, dx = 1 cm, VT = -6.479862E-04 VS 10:56:34 Wire moved to X = .5 cm 10:56:39 Wire moved by DX = -1 cm 10:56:45 X0 = 0 cm, dx = -1 cm, VT = 6.546056E-04 VS 10:56:47 Wire moved to X = -.5 cm 10:56:52 Wire moved by DX = 1 cm 10:56:58 X0 = 0 cm, dx = 1 cm, VT = -6.451615E-04 VS 10:56:59 Wire moved to X = .5 cm 10:57:04 Wire moved by DX = -1 cm 10:57:10 X0 = 0 cm, dx = -1 cm, VT = 6.596417E-04 VS 10:57:12 Wire moved to X = -.5 cm 10:57:17 Wire moved by DX = 1 cm 10:57:23 X0 = 0 cm, dx = 1 cm, VT = -6.443911E-04 VS 10:57:24 Wire moved to X = .5 cm 10:57:29 Wire moved by DX = -1 cm 10:57:35 X0 = 0 cm, dx = -1 cm, VT = 6.547552E-04 VS 10:57:37 Wire moved to X = -.5 cm 10:57:42 Wire moved by DX = 1 cm 10:57:48 X0 = 0 cm, dx = 1 cm, VT = -6.450365E-04 VS 10:57:49 Wire moved to X = .5 cm 10:57:54 Wire moved by DX = -1 cm 10:58:00 X0 = 0 cm, dx = -1 cm, VT = 6.583757E-04 VS 10:58:00 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = -6.512442E-04 +- 1.042589E-06 VS (= Tm^2) 10:58:03 Wire moved to X = 0 cm 10:58:04 Magnet Current, Imag = 3.060408 A 10:58:04 Magnet Current Ramping to 2 A... 10:58:20 Magnet Current, Imag = 2.042753 A 10:58:23 Magnet Current, Imag = 2.042753 A 10:58:24 Magnet Current, Imag = 2.042753 A 10:58:26 Magnet Current, Imag = 2.042753 A 10:58:27 Magnet Current, Imag = 2.042753 A 10:58:27 Magnet Current Measurement: Imag = 2.042753 +- 0 A 10:58:29 Wire moved to X = -.5 cm 10:58:34 Wire moved by DX = 1 cm 10:58:40 X0 = 0 cm, dx = 1 cm, VT = -4.395046E-04 VS 10:58:42 Wire moved to X = .5 cm 10:58:47 Wire moved by DX = -1 cm 10:58:53 X0 = 0 cm, dx = -1 cm, VT = 4.458732E-04 VS 10:58:54 Wire moved to X = -.5 cm 10:58:59 Wire moved by DX = 1 cm 10:59:05 X0 = 0 cm, dx = 1 cm, VT = -4.353054E-04 VS 10:59:07 Wire moved to X = .5 cm 10:59:12 Wire moved by DX = -1 cm 10:59:18 X0 = 0 cm, dx = -1 cm, VT = 4.462424E-04 VS 10:59:19 Wire moved to X = -.5 cm 10:59:24 Wire moved by DX = 1 cm 10:59:30 X0 = 0 cm, dx = 1 cm, VT = -4.292542E-04 VS 10:59:32 Wire moved to X = .5 cm 10:59:37 Wire moved by DX = -1 cm 10:59:43 X0 = 0 cm, dx = -1 cm, VT = 4.437935E-04 VS 10:59:44 Wire moved to X = -.5 cm 10:59:49 Wire moved by DX = 1 cm 10:59:55 X0 = 0 cm, dx = 1 cm, VT = -4.31523E-04 VS 10:59:57 Wire moved to X = .5 cm 11:00:02 Wire moved by DX = -1 cm 11:00:08 X0 = 0 cm, dx = -1 cm, VT = 4.457602E-04 VS 11:00:08 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = -4.396571E-04 +- 2.306945E-06 VS (= Tm^2) 11:00:10 Wire moved to X = 0 cm 11:00:11 Magnet Current, Imag = 2.042788 A 11:00:11 Magnet Current Ramping to 1 A... 11:00:28 Magnet Current, Imag = 1.025985 A 11:00:31 Magnet Current, Imag = 1.025988 A 11:00:32 Magnet Current, Imag = 1.025985 A 11:00:33 Magnet Current, Imag = 1.025982 A 11:00:34 Magnet Current, Imag = 1.025982 A 11:00:34 Magnet Current Measurement: Imag = 1.025984 +- 2.07763E-06 A 11:00:36 Wire moved to X = -.5 cm 11:00:42 Wire moved by DX = 1 cm 11:00:48 X0 = 0 cm, dx = 1 cm, VT = -2.258092E-04 VS 11:00:49 Wire moved to X = .5 cm 11:00:54 Wire moved by DX = -1 cm 11:01:00 X0 = 0 cm, dx = -1 cm, VT = 2.339181E-04 VS 11:01:02 Wire moved to X = -.5 cm 11:01:07 Wire moved by DX = 1 cm 11:01:13 X0 = 0 cm, dx = 1 cm, VT = -2.150638E-04 VS 11:01:14 Wire moved to X = .5 cm 11:01:19 Wire moved by DX = -1 cm 11:01:25 X0 = 0 cm, dx = -1 cm, VT = 2.330198E-04 VS 11:01:26 Wire moved to X = -.5 cm 11:01:31 Wire moved by DX = 1 cm 11:01:38 X0 = 0 cm, dx = 1 cm, VT = -2.187962E-04 VS 11:01:39 Wire moved to X = .5 cm 11:01:44 Wire moved by DX = -1 cm 11:01:50 X0 = 0 cm, dx = -1 cm, VT = 2.417942E-04 VS 11:01:51 Wire moved to X = -.5 cm 11:01:56 Wire moved by DX = 1 cm 11:02:02 X0 = 0 cm, dx = 1 cm, VT = -2.158001E-04 VS 11:02:04 Wire moved to X = .5 cm 11:02:09 Wire moved by DX = -1 cm 11:02:15 X0 = 0 cm, dx = -1 cm, VT = 2.368521E-04 VS 11:02:15 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = -2.276317E-04 +- 2.582045E-06 VS (= Tm^2) 11:02:17 Wire moved to X = 0 cm 11:02:19 Magnet Current, Imag = 1.025988 A 11:02:19 Magnet Current Ramping to 0 A... 11:02:35 Magnet Current, Imag = 8.259974E-03 A 11:02:39 Magnet Current, Imag = .0082685 A 11:02:40 Magnet Current, Imag = 8.265224E-03 A 11:02:42 Magnet Current, Imag = 8.26485E-03 A 11:02:44 Magnet Current, Imag = 8.267075E-03 A 11:02:44 Magnet Current Measurement: Imag = 8.266413E-03 +- 1.470448E-06 A 11:02:46 Wire moved to X = -.5 cm 11:02:51 Wire moved by DX = 1 cm 11:02:57 X0 = 0 cm, dx = 1 cm, VT = -2.903974E-06 VS 11:02:59 Wire moved to X = .5 cm 11:03:04 Wire moved by DX = -1 cm 11:03:10 X0 = 0 cm, dx = -1 cm, VT = 2.598343E-05 VS 11:03:11 Wire moved to X = -.5 cm 11:03:16 Wire moved by DX = 1 cm 11:03:22 X0 = 0 cm, dx = 1 cm, VT = -7.814528E-06 VS 11:03:24 Wire moved to X = .5 cm 11:03:29 Wire moved by DX = -1 cm 11:03:35 X0 = 0 cm, dx = -1 cm, VT = 2.678927E-05 VS 11:03:36 Wire moved to X = -.5 cm 11:03:41 Wire moved by DX = 1 cm 11:03:47 X0 = 0 cm, dx = 1 cm, VT = -4.044289E-06 VS 11:03:48 Wire moved to X = .5 cm 11:03:53 Wire moved by DX = -1 cm 11:04:00 X0 = 0 cm, dx = -1 cm, VT = 2.791359E-05 VS 11:04:01 Wire moved to X = -.5 cm 11:04:06 Wire moved by DX = 1 cm 11:04:12 X0 = 0 cm, dx = 1 cm, VT = -1.109938E-05 VS 11:04:13 Wire moved to X = .5 cm 11:04:18 Wire moved by DX = -1 cm 11:04:25 X0 = 0 cm, dx = -1 cm, VT = 3.061701E-05 VS 11:04:25 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = -1.714568E-05 +- 2.370081E-06 VS (= Tm^2) 11:04:27 Wire moved to X = 0 cm 11:04:29 Magnet Current, Imag = .0082816 A 11:04:29 Magnet Current Ramping to -1 A... 11:04:45 Magnet Current, Imag = -1.02669 A 11:04:48 Magnet Current, Imag = -1.02669 A 11:04:49 Magnet Current, Imag = -1.026698 A 11:04:51 Magnet Current, Imag = -1.026703 A 11:04:52 Magnet Current, Imag = -1.026698 A 11:04:52 Magnet Current Measurement: Imag = -1.026697 +- 4.469553E-06 A 11:04:54 Wire moved to X = -.5 cm 11:04:59 Wire moved by DX = 1 cm 11:05:05 X0 = 0 cm, dx = 1 cm, VT = 2.182147E-04 VS 11:05:07 Wire moved to X = .5 cm 11:05:12 Wire moved by DX = -1 cm 11:05:18 X0 = 0 cm, dx = -1 cm, VT = -1.88342E-04 VS 11:05:19 Wire moved to X = -.5 cm 11:05:24 Wire moved by DX = 1 cm 11:05:31 X0 = 0 cm, dx = 1 cm, VT = 2.110024E-04 VS 11:05:32 Wire moved to X = .5 cm 11:05:37 Wire moved by DX = -1 cm 11:05:43 X0 = 0 cm, dx = -1 cm, VT = -1.876008E-04 VS 11:05:44 Wire moved to X = -.5 cm 11:05:49 Wire moved by DX = 1 cm 11:05:56 X0 = 0 cm, dx = 1 cm, VT = 2.181903E-04 VS 11:05:57 Wire moved to X = .5 cm 11:06:02 Wire moved by DX = -1 cm 11:06:08 X0 = 0 cm, dx = -1 cm, VT = -1.881087E-04 VS 11:06:09 Wire moved to X = -.5 cm 11:06:14 Wire moved by DX = 1 cm 11:06:21 X0 = 0 cm, dx = 1 cm, VT = 2.114949E-04 VS 11:06:22 Wire moved to X = .5 cm 11:06:27 Wire moved by DX = -1 cm 11:06:33 X0 = 0 cm, dx = -1 cm, VT = -1.922958E-04 VS 11:06:33 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 2.019062E-04 +- 1.59785E-06 VS (= Tm^2) 11:06:35 Wire moved to X = 0 cm 11:06:37 Magnet Current, Imag = -1.026692 A 11:06:37 Magnet Current Ramping to -2 A... 11:06:53 Magnet Current, Imag = -2.04348 A 11:06:55 Magnet Current, Imag = -2.043477 A 11:06:57 Magnet Current, Imag = -2.043477 A 11:06:58 Magnet Current, Imag = -2.043465 A 11:06:59 Magnet Current, Imag = -2.043473 A 11:06:59 Magnet Current Measurement: Imag = -2.043473 +- 5.068849E-06 A 11:07:02 Wire moved to X = -.5 cm 11:07:07 Wire moved by DX = 1 cm 11:07:13 X0 = 0 cm, dx = 1 cm, VT = 4.250132E-04 VS 11:07:14 Wire moved to X = .5 cm 11:07:19 Wire moved by DX = -1 cm 11:07:25 X0 = 0 cm, dx = -1 cm, VT = -4.017023E-04 VS 11:07:27 Wire moved to X = -.5 cm 11:07:32 Wire moved by DX = 1 cm 11:07:38 X0 = 0 cm, dx = 1 cm, VT = 4.231584E-04 VS 11:07:39 Wire moved to X = .5 cm 11:07:44 Wire moved by DX = -1 cm 11:07:50 X0 = 0 cm, dx = -1 cm, VT = -4.025301E-04 VS 11:07:52 Wire moved to X = -.5 cm 11:07:57 Wire moved by DX = 1 cm 11:08:03 X0 = 0 cm, dx = 1 cm, VT = 4.3037E-04 VS 11:08:04 Wire moved to X = .5 cm 11:08:09 Wire moved by DX = -1 cm 11:08:15 X0 = 0 cm, dx = -1 cm, VT = -4.020722E-04 VS 11:08:17 Wire moved to X = -.5 cm 11:08:22 Wire moved by DX = 1 cm 11:08:28 X0 = 0 cm, dx = 1 cm, VT = 4.264252E-04 VS 11:08:29 Wire moved to X = .5 cm 11:08:34 Wire moved by DX = -1 cm 11:08:40 X0 = 0 cm, dx = -1 cm, VT = -4.028491E-04 VS 11:08:40 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 4.142651E-04 +- 1.304462E-06 VS (= Tm^2) 11:08:43 Wire moved to X = 0 cm 11:08:44 Magnet Current, Imag = -2.043442 A 11:08:44 Magnet Current Ramping to -3 A... 11:09:00 Magnet Current, Imag = -3.061073 A 11:09:03 Magnet Current, Imag = -3.061075 A 11:09:04 Magnet Current, Imag = -3.061073 A 11:09:05 Magnet Current, Imag = -3.061078 A 11:09:06 Magnet Current, Imag = -3.061078 A 11:09:06 Magnet Current Measurement: Imag = -3.061076 +- 2.085311E-06 A 11:09:09 Wire moved to X = -.5 cm 11:09:14 Wire moved by DX = 1 cm 11:09:20 X0 = 0 cm, dx = 1 cm, VT = 6.374385E-04 VS 11:09:21 Wire moved to X = .5 cm 11:09:26 Wire moved by DX = -1 cm 11:09:32 X0 = 0 cm, dx = -1 cm, VT = -6.204455E-04 VS 11:09:34 Wire moved to X = -.5 cm 11:09:39 Wire moved by DX = 1 cm 11:09:45 X0 = 0 cm, dx = 1 cm, VT = 6.350011E-04 VS 11:09:46 Wire moved to X = .5 cm 11:09:51 Wire moved by DX = -1 cm 11:09:57 X0 = 0 cm, dx = -1 cm, VT = -6.217161E-04 VS 11:09:59 Wire moved to X = -.5 cm 11:10:04 Wire moved by DX = 1 cm 11:10:10 X0 = 0 cm, dx = 1 cm, VT = 6.359079E-04 VS 11:10:11 Wire moved to X = .5 cm 11:10:16 Wire moved by DX = -1 cm 11:10:22 X0 = 0 cm, dx = -1 cm, VT = -6.250686E-04 VS 11:10:24 Wire moved to X = -.5 cm 11:10:29 Wire moved by DX = 1 cm 11:10:35 X0 = 0 cm, dx = 1 cm, VT = 6.356823E-04 VS 11:10:36 Wire moved to X = .5 cm 11:10:41 Wire moved by DX = -1 cm 11:10:47 X0 = 0 cm, dx = -1 cm, VT = -6.225245E-04 VS 11:10:47 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 6.292231E-04 +- 7.812371E-07 VS (= Tm^2) 11:10:50 Wire moved to X = 0 cm 11:10:51 Magnet Current, Imag = -3.061017 A 11:10:51 Magnet Current Ramping to -4 A... 11:11:07 Magnet Current, Imag = -4.077578 A 11:11:10 Magnet Current, Imag = -4.077572 A 11:11:11 Magnet Current, Imag = -4.077565 A 11:11:12 Magnet Current, Imag = -4.077565 A 11:11:13 Magnet Current, Imag = -4.077552 A 11:11:13 Magnet Current Measurement: Imag = -4.077564 +- 7.223729E-06 A 11:11:16 Wire moved to X = -.5 cm 11:11:21 Wire moved by DX = 1 cm 11:11:27 X0 = 0 cm, dx = 1 cm, VT = 8.495578E-04 VS 11:11:28 Wire moved to X = .5 cm 11:11:33 Wire moved by DX = -1 cm 11:11:39 X0 = 0 cm, dx = -1 cm, VT = -8.314254E-04 VS 11:11:41 Wire moved to X = -.5 cm 11:11:46 Wire moved by DX = 1 cm 11:11:52 X0 = 0 cm, dx = 1 cm, VT = 8.509855E-04 VS 11:11:53 Wire moved to X = .5 cm 11:11:58 Wire moved by DX = -1 cm 11:12:04 X0 = 0 cm, dx = -1 cm, VT = -8.296696E-04 VS 11:12:06 Wire moved to X = -.5 cm 11:12:11 Wire moved by DX = 1 cm 11:12:17 X0 = 0 cm, dx = 1 cm, VT = 8.577353E-04 VS 11:12:18 Wire moved to X = .5 cm 11:12:23 Wire moved by DX = -1 cm 11:12:29 X0 = 0 cm, dx = -1 cm, VT = -8.294337E-04 VS 11:12:31 Wire moved to X = -.5 cm 11:12:36 Wire moved by DX = 1 cm 11:12:42 X0 = 0 cm, dx = 1 cm, VT = 8.573279E-04 VS 11:12:43 Wire moved to X = .5 cm 11:12:48 Wire moved by DX = -1 cm 11:12:55 X0 = 0 cm, dx = -1 cm, VT = -8.297037E-04 VS 11:12:55 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 8.419799E-04 +- 1.571555E-06 VS (= Tm^2) 11:12:57 Wire moved to X = 0 cm 11:12:58 Magnet Current, Imag = -4.077437 A 11:12:58 Magnet Current Ramping to -5 A... 11:13:14 Magnet Current, Imag = -5.095022 A 11:13:17 Magnet Current, Imag = -5.095017 A 11:13:18 Magnet Current, Imag = -5.09501 A 11:13:19 Magnet Current, Imag = -5.095005 A 11:13:21 Magnet Current, Imag = -5.094997 A 11:13:21 Magnet Current Measurement: Imag = -5.095007 +- 7.278603E-06 A 11:13:23 Wire moved to X = -.5 cm 11:13:28 Wire moved by DX = 1 cm 11:13:34 X0 = 0 cm, dx = 1 cm, VT = 1.064784E-03 VS 11:13:35 Wire moved to X = .5 cm 11:13:40 Wire moved by DX = -1 cm 11:13:47 X0 = 0 cm, dx = -1 cm, VT = -1.04357E-03 VS 11:13:48 Wire moved to X = -.5 cm 11:13:53 Wire moved by DX = 1 cm 11:13:59 X0 = 0 cm, dx = 1 cm, VT = 1.063807E-03 VS 11:14:00 Wire moved to X = .5 cm 11:14:05 Wire moved by DX = -1 cm 11:14:12 X0 = 0 cm, dx = -1 cm, VT = -1.050358E-03 VS 11:14:13 Wire moved to X = -.5 cm 11:14:18 Wire moved by DX = 1 cm 11:14:24 X0 = 0 cm, dx = 1 cm, VT = 1.063439E-03 VS 11:14:25 Wire moved to X = .5 cm 11:14:30 Wire moved by DX = -1 cm 11:14:37 X0 = 0 cm, dx = -1 cm, VT = -1.046794E-03 VS 11:14:38 Wire moved to X = -.5 cm 11:14:43 Wire moved by DX = 1 cm 11:14:49 X0 = 0 cm, dx = 1 cm, VT = 1.060131E-03 VS 11:14:50 Wire moved to X = .5 cm 11:14:55 Wire moved by DX = -1 cm 11:15:02 X0 = 0 cm, dx = -1 cm, VT = -1.05059E-03 VS 11:15:02 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.055434E-03 +- 1.049045E-06 VS (= Tm^2) 11:15:04 Wire moved to X = 0 cm 11:15:05 Magnet Current, Imag = -5.094827 A 11:15:06 Magnet Current Ramping to -6 A... 11:15:21 Magnet Current, Imag = -6.111517 A 11:15:24 Magnet Current, Imag = -6.111517 A 11:15:25 Magnet Current, Imag = -6.111505 A 11:15:27 Magnet Current, Imag = -6.111497 A 11:15:28 Magnet Current, Imag = -6.111488 A 11:15:28 Magnet Current Measurement: Imag = -6.111502 +- 1.082116E-05 A 11:15:30 Wire moved to X = -.5 cm 11:15:35 Wire moved by DX = 1 cm 11:15:41 X0 = 0 cm, dx = 1 cm, VT = 1.273792E-03 VS 11:15:43 Wire moved to X = .5 cm 11:15:48 Wire moved by DX = -1 cm 11:15:54 X0 = 0 cm, dx = -1 cm, VT = -1.260135E-03 VS 11:15:55 Wire moved to X = -.5 cm 11:16:00 Wire moved by DX = 1 cm 11:16:06 X0 = 0 cm, dx = 1 cm, VT = 1.274403E-03 VS 11:16:08 Wire moved to X = .5 cm 11:16:13 Wire moved by DX = -1 cm 11:16:19 X0 = 0 cm, dx = -1 cm, VT = -1.256703E-03 VS 11:16:20 Wire moved to X = -.5 cm 11:16:25 Wire moved by DX = 1 cm 11:16:31 X0 = 0 cm, dx = 1 cm, VT = 1.277598E-03 VS 11:16:33 Wire moved to X = .5 cm 11:16:38 Wire moved by DX = -1 cm 11:16:44 X0 = 0 cm, dx = -1 cm, VT = -1.256187E-03 VS 11:16:45 Wire moved to X = -.5 cm 11:16:50 Wire moved by DX = 1 cm 11:16:56 X0 = 0 cm, dx = 1 cm, VT = 1.280907E-03 VS 11:16:58 Wire moved to X = .5 cm 11:17:03 Wire moved by DX = -1 cm 11:17:09 X0 = 0 cm, dx = -1 cm, VT = -1.256127E-03 VS 11:17:09 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.266981E-03 +- 1.049583E-06 VS (= Tm^2) 11:17:11 Wire moved to X = 0 cm 11:17:12 Magnet Current, Imag = -6.111217 A 11:17:13 Magnet Current Ramping to -5 A... 11:17:28 Magnet Current, Imag = -5.094525 A 11:17:31 Magnet Current, Imag = -5.094535 A 11:17:32 Magnet Current, Imag = -5.094545 A 11:17:33 Magnet Current, Imag = -5.094547 A 11:17:35 Magnet Current, Imag = -5.09455 A 11:17:35 Magnet Current Measurement: Imag = -5.094544 +- 5.746827E-06 A 11:17:37 Wire moved to X = -.5 cm 11:17:42 Wire moved by DX = 1 cm 11:17:48 X0 = 0 cm, dx = 1 cm, VT = 1.082921E-03 VS 11:17:50 Wire moved to X = .5 cm 11:17:55 Wire moved by DX = -1 cm 11:18:01 X0 = 0 cm, dx = -1 cm, VT = -1.060771E-03 VS 11:18:02 Wire moved to X = -.5 cm 11:18:07 Wire moved by DX = 1 cm 11:18:13 X0 = 0 cm, dx = 1 cm, VT = 1.083387E-03 VS 11:18:15 Wire moved to X = .5 cm 11:18:20 Wire moved by DX = -1 cm 11:18:26 X0 = 0 cm, dx = -1 cm, VT = -1.057224E-03 VS 11:18:27 Wire moved to X = -.5 cm 11:18:32 Wire moved by DX = 1 cm 11:18:38 X0 = 0 cm, dx = 1 cm, VT = 1.082521E-03 VS 11:18:40 Wire moved to X = .5 cm 11:18:44 Wire moved by DX = -1 cm 11:18:51 X0 = 0 cm, dx = -1 cm, VT = -1.058297E-03 VS 11:18:52 Wire moved to X = -.5 cm 11:18:57 Wire moved by DX = 1 cm 11:19:03 X0 = 0 cm, dx = 1 cm, VT = 1.080538E-03 VS 11:19:04 Wire moved to X = .5 cm 11:19:09 Wire moved by DX = -1 cm 11:19:16 X0 = 0 cm, dx = -1 cm, VT = -1.059063E-03 VS 11:19:16 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.07059E-03 +- 7.606713E-07 VS (= Tm^2) 11:19:18 Wire moved to X = 0 cm 11:19:19 Magnet Current, Imag = -5.094625 A 11:19:19 Magnet Current Ramping to -4 A... 11:19:35 Magnet Current, Imag = -4.077083 A 11:19:38 Magnet Current, Imag = -4.077085 A 11:19:39 Magnet Current, Imag = -4.077087 A 11:19:40 Magnet Current, Imag = -4.077095 A 11:19:42 Magnet Current, Imag = -4.0771 A 11:19:42 Magnet Current Measurement: Imag = -4.077092 +- 5.922195E-06 A 11:19:44 Wire moved to X = -.5 cm 11:19:49 Wire moved by DX = 1 cm 11:19:55 X0 = 0 cm, dx = 1 cm, VT = 8.762069E-04 VS 11:19:57 Wire moved to X = .5 cm 11:20:02 Wire moved by DX = -1 cm 11:20:08 X0 = 0 cm, dx = -1 cm, VT = -8.513216E-04 VS 11:20:09 Wire moved to X = -.5 cm 11:20:14 Wire moved by DX = 1 cm 11:20:20 X0 = 0 cm, dx = 1 cm, VT = 8.801307E-04 VS 11:20:21 Wire moved to X = .5 cm 11:20:27 Wire moved by DX = -1 cm 11:20:33 X0 = 0 cm, dx = -1 cm, VT = -8.563445E-04 VS 11:20:34 Wire moved to X = -.5 cm 11:20:39 Wire moved by DX = 1 cm 11:20:45 X0 = 0 cm, dx = 1 cm, VT = 8.761441E-04 VS 11:20:46 Wire moved to X = .5 cm 11:20:51 Wire moved by DX = -1 cm 11:20:58 X0 = 0 cm, dx = -1 cm, VT = -8.517528E-04 VS 11:20:59 Wire moved to X = -.5 cm 11:21:04 Wire moved by DX = 1 cm 11:21:10 X0 = 0 cm, dx = 1 cm, VT = 8.765495E-04 VS 11:21:11 Wire moved to X = .5 cm 11:21:16 Wire moved by DX = -1 cm 11:21:22 X0 = 0 cm, dx = -1 cm, VT = -8.579961E-04 VS 11:21:23 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 8.658058E-04 +- 1.980136E-06 VS (= Tm^2) 11:21:25 Wire moved to X = 0 cm 11:21:26 Magnet Current, Imag = -4.077198 A 11:21:26 Magnet Current Ramping to -3 A... 11:21:42 Magnet Current, Imag = -3.060688 A 11:21:45 Magnet Current, Imag = -3.060702 A 11:21:46 Magnet Current, Imag = -3.06071 A 11:21:47 Magnet Current, Imag = -3.060702 A 11:21:49 Magnet Current, Imag = -3.060713 A 11:21:49 Magnet Current Measurement: Imag = -3.060707 +- 4.607713E-06 A 11:21:51 Wire moved to X = -.5 cm 11:21:56 Wire moved by DX = 1 cm 11:22:02 X0 = 0 cm, dx = 1 cm, VT = 6.632102E-04 VS 11:22:04 Wire moved to X = .5 cm 11:22:09 Wire moved by DX = -1 cm 11:22:15 X0 = 0 cm, dx = -1 cm, VT = -6.464256E-04 VS 11:22:16 Wire moved to X = -.5 cm 11:22:21 Wire moved by DX = 1 cm 11:22:27 X0 = 0 cm, dx = 1 cm, VT = 6.65989E-04 VS 11:22:28 Wire moved to X = .5 cm 11:22:33 Wire moved by DX = -1 cm 11:22:40 X0 = 0 cm, dx = -1 cm, VT = -6.469872E-04 VS 11:22:41 Wire moved to X = -.5 cm 11:22:46 Wire moved by DX = 1 cm 11:22:52 X0 = 0 cm, dx = 1 cm, VT = 6.602232E-04 VS 11:22:53 Wire moved to X = .5 cm 11:22:58 Wire moved by DX = -1 cm 11:23:05 X0 = 0 cm, dx = -1 cm, VT = -6.469227E-04 VS 11:23:06 Wire moved to X = -.5 cm 11:23:11 Wire moved by DX = 1 cm 11:23:17 X0 = 0 cm, dx = 1 cm, VT = 6.662131E-04 VS 11:23:18 Wire moved to X = .5 cm 11:23:23 Wire moved by DX = -1 cm 11:23:30 X0 = 0 cm, dx = -1 cm, VT = -6.476474E-04 VS 11:23:30 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 6.554523E-04 +- 1.340864E-06 VS (= Tm^2) 11:23:32 Wire moved to X = 0 cm 11:23:33 Magnet Current, Imag = -3.060795 A 11:23:33 Magnet Current Ramping to -2 A... 11:23:49 Magnet Current, Imag = -2.043217 A 11:23:52 Magnet Current, Imag = -2.043215 A 11:23:53 Magnet Current, Imag = -2.043217 A 11:23:54 Magnet Current, Imag = -2.043217 A 11:23:56 Magnet Current, Imag = -2.043217 A 11:23:56 Magnet Current Measurement: Imag = -2.043217 +- 1.039243E-06 A 11:23:58 Wire moved to X = -.5 cm 11:24:03 Wire moved by DX = 1 cm 11:24:09 X0 = 0 cm, dx = 1 cm, VT = 4.595928E-04 VS 11:24:10 Wire moved to X = .5 cm 11:24:16 Wire moved by DX = -1 cm 11:24:22 X0 = 0 cm, dx = -1 cm, VT = -4.333986E-04 VS 11:24:23 Wire moved to X = -.5 cm 11:24:28 Wire moved by DX = 1 cm 11:24:34 X0 = 0 cm, dx = 1 cm, VT = 4.646643E-04 VS 11:24:36 Wire moved to X = .5 cm 11:24:41 Wire moved by DX = -1 cm 11:24:47 X0 = 0 cm, dx = -1 cm, VT = -4.292185E-04 VS 11:24:48 Wire moved to X = -.5 cm 11:24:53 Wire moved by DX = 1 cm 11:24:59 X0 = 0 cm, dx = 1 cm, VT = 4.622066E-04 VS 11:25:01 Wire moved to X = .5 cm 11:25:06 Wire moved by DX = -1 cm 11:25:12 X0 = 0 cm, dx = -1 cm, VT = -4.295245E-04 VS 11:25:13 Wire moved to X = -.5 cm 11:25:18 Wire moved by DX = 1 cm 11:25:24 X0 = 0 cm, dx = 1 cm, VT = 4.605788E-04 VS 11:25:26 Wire moved to X = .5 cm 11:25:31 Wire moved by DX = -1 cm 11:25:37 X0 = 0 cm, dx = -1 cm, VT = -4.317745E-04 VS 11:25:37 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 4.463698E-04 +- 3.981534E-07 VS (= Tm^2) 11:25:39 Wire moved to X = 0 cm 11:25:41 Magnet Current, Imag = -2.043278 A 11:25:41 Magnet Current Ramping to -1 A... 11:25:56 Magnet Current, Imag = -1.026545 A 11:25:59 Magnet Current, Imag = -1.026545 A 11:26:00 Magnet Current, Imag = -1.026545 A 11:26:02 Magnet Current, Imag = -1.026555 A 11:26:03 Magnet Current, Imag = -1.026558 A 11:26:03 Magnet Current Measurement: Imag = -1.026551 +- 5.679044E-06 A 11:26:05 Wire moved to X = -.5 cm 11:26:10 Wire moved by DX = 1 cm 11:26:16 X0 = 0 cm, dx = 1 cm, VT = 2.466693E-04 VS 11:26:18 Wire moved to X = .5 cm 11:26:23 Wire moved by DX = -1 cm 11:26:29 X0 = 0 cm, dx = -1 cm, VT = -2.227636E-04 VS 11:26:30 Wire moved to X = -.5 cm 11:26:35 Wire moved by DX = 1 cm 11:26:41 X0 = 0 cm, dx = 1 cm, VT = 2.426729E-04 VS 11:26:43 Wire moved to X = .5 cm 11:26:48 Wire moved by DX = -1 cm 11:26:54 X0 = 0 cm, dx = -1 cm, VT = -2.276233E-04 VS 11:26:55 Wire moved to X = -.5 cm 11:27:00 Wire moved by DX = 1 cm 11:27:06 X0 = 0 cm, dx = 1 cm, VT = 2.406029E-04 VS 11:27:08 Wire moved to X = .5 cm 11:27:13 Wire moved by DX = -1 cm 11:27:19 X0 = 0 cm, dx = -1 cm, VT = -2.257123E-04 VS 11:27:20 Wire moved to X = -.5 cm 11:27:25 Wire moved by DX = 1 cm 11:27:31 X0 = 0 cm, dx = 1 cm, VT = 2.457641E-04 VS 11:27:33 Wire moved to X = .5 cm 11:27:38 Wire moved by DX = -1 cm 11:27:44 X0 = 0 cm, dx = -1 cm, VT = -2.239345E-04 VS 11:27:44 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 2.344679E-04 +- 7.724593E-07 VS (= Tm^2) 11:27:46 Wire moved to X = 0 cm 11:27:48 Magnet Current, Imag = -1.026585 A 11:27:48 Magnet Current Ramping to 0 A... 11:28:04 Magnet Current, Imag = .0083962 A 11:28:08 Magnet Current, Imag = 8.392475E-03 A 11:28:09 Magnet Current, Imag = 8.394225E-03 A 11:28:11 Magnet Current, Imag = .0083965 A 11:28:13 Magnet Current, Imag = .0083922 A 11:28:13 Magnet Current Measurement: Imag = 8.393849E-03 +- 1.71583E-06 A 11:28:15 Wire moved to X = -.5 cm 11:28:20 Wire moved by DX = 1 cm 11:28:26 X0 = 0 cm, dx = 1 cm, VT = 2.821248E-05 VS 11:28:28 Wire moved to X = .5 cm 11:28:33 Wire moved by DX = -1 cm 11:28:39 X0 = 0 cm, dx = -1 cm, VT = -6.735008E-06 VS 11:28:40 Wire moved to X = -.5 cm 11:28:45 Wire moved by DX = 1 cm 11:28:51 X0 = 0 cm, dx = 1 cm, VT = 3.212265E-05 VS 11:28:53 Wire moved to X = .5 cm 11:28:58 Wire moved by DX = -1 cm 11:29:04 X0 = 0 cm, dx = -1 cm, VT = -5.734018E-06 VS 11:29:05 Wire moved to X = -.5 cm 11:29:10 Wire moved by DX = 1 cm 11:29:16 X0 = 0 cm, dx = 1 cm, VT = 3.145447E-05 VS 11:29:18 Wire moved to X = .5 cm 11:29:23 Wire moved by DX = -1 cm 11:29:29 X0 = 0 cm, dx = -1 cm, VT = -1.990338E-06 VS 11:29:30 Wire moved to X = -.5 cm 11:29:35 Wire moved by DX = 1 cm 11:29:41 X0 = 0 cm, dx = 1 cm, VT = 3.321843E-05 VS 11:29:43 Wire moved to X = .5 cm 11:29:48 Wire moved by DX = -1 cm 11:29:54 X0 = 0 cm, dx = -1 cm, VT = -4.326528E-06 VS 11:29:54 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.797424E-05 +- 9.172066E-07 VS (= Tm^2) 11:29:56 Wire moved to X = 0 cm 11:29:58 Magnet Current, Imag = .0083681 A 11:29:58 Magnet Current Ramping to 0 A... 11:30:11 Magnet Current, Imag = .0083613 A