SLAC Magnetic Measurements Date: 08-23-1996 Time: 13:44:40 Project: PEP2HER Magnet Type: DIPOLE Magnet Name (Serial #): B3_1 Bar Code Number: Test Stand: 5 Measurement System: STRETCHED WIRE Operator: zw Run Number: 8 Comment: BL vs X, X = 0 is -5.5cm from center, +X is away from leads Standardization Currents 3 cycles, 10 to 170 to 10 A Test Currents 0.0 25.0 50.0 75.0 85.0 100.0 125.0 150.0 13:46:24 Magnet Current Ramping to 170 A... 13:51:21 Magnet Current Ramping to 10 A... 13:55:50 Magnet Current Ramping to 170 A... 14:00:37 Magnet Current Ramping to 10 A... 14:05:06 Magnet Current Ramping to 170 A... 14:09:54 Magnet Current Ramping to 10 A... 14:17:22 Magnet Current Ramping to 50 A... 14:19:04 Magnet Current Measurement... 14:19:06 Power Supply 1 Current, Ips = 50.23022 A 14:19:06 Magnet Current, Imag = 50.23022 A 14:19:08 Power Supply 1 Current, Ips = 50.23446 A 14:19:08 Magnet Current, Imag = 50.23446 A 14:19:10 Power Supply 1 Current, Ips = 50.22172 A 14:19:10 Magnet Current, Imag = 50.22172 A 14:19:11 Power Supply 1 Current, Ips = 50.22849 A 14:19:12 Magnet Current, Imag = 50.22849 A 14:19:12 Magnet Current Measurement: Imag = 50.22872 +- 4.591524E-03 A 14:19:12 Integrated Voltage Measurement... 14:19:27 Wire moved to X = -5.5 cm 14:19:31 Wire moved by DX = 1 cm 14:19:39 X0 = -5 cm, dx = 1 cm, VT = 5.486277E-03 VS 14:19:41 Wire moved to X = -4.5 cm 14:19:45 Wire moved by DX = -1 cm 14:19:53 X0 = -5 cm, dx = -1 cm, VT = -5.498982E-03 VS 14:19:55 Wire moved to X = -5.5 cm 14:19:59 Wire moved by DX = 1 cm 14:20:07 X0 = -5 cm, dx = 1 cm, VT = 5.490341E-03 VS 14:20:09 Wire moved to X = -4.5 cm 14:20:13 Wire moved by DX = -1 cm 14:20:22 X0 = -5 cm, dx = -1 cm, VT = -5.434062E-03 VS 14:20:23 Wire moved to X = -5.5 cm 14:20:27 Wire moved by DX = 1 cm 14:20:36 X0 = -5 cm, dx = 1 cm, VT = 5.453412E-03 VS 14:20:37 Wire moved to X = -4.5 cm 14:20:41 Wire moved by DX = -1 cm 14:20:50 X0 = -5 cm, dx = -1 cm, VT = -5.451346E-03 VS 14:20:51 Wire moved to X = -5.5 cm 14:20:55 Wire moved by DX = 1 cm 14:21:04 X0 = -5 cm, dx = 1 cm, VT = 5.45455E-03 VS 14:21:05 Wire moved to X = -4.5 cm 14:21:09 Wire moved by DX = -1 cm 14:21:18 X0 = -5 cm, dx = -1 cm, VT = -5.507805E-03 VS 14:21:18 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -5 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 5.472097E-03 +- 1.573808E-05 VS (= Tm^2) 14:21:18 The integrated field strength is BL = 5.472096E-02 +- 1.573808E-04 Tm 14:21:18 Magnet Current Measurement... 14:21:20 Power Supply 1 Current, Ips = 50.22692 A 14:21:20 Magnet Current, Imag = 50.22692 A 14:21:22 Power Supply 1 Current, Ips = 50.24166 A 14:21:22 Magnet Current, Imag = 50.24166 A 14:21:24 Power Supply 1 Current, Ips = 50.24478 A 14:21:24 Magnet Current, Imag = 50.24478 A 14:21:26 Power Supply 1 Current, Ips = 50.25664 A 14:21:26 Magnet Current, Imag = 50.25664 A 14:21:26 Magnet Current Measurement: Imag = 50.2425 +- 1.058977E-02 A 14:21:26 Integrated Voltage Measurement... 14:21:29 Wire moved to X = -4.5 cm 14:21:34 Wire moved by DX = 1 cm 14:21:42 X0 = -4 cm, dx = 1 cm, VT = 5.509314E-03 VS 14:21:43 Wire moved to X = -3.5 cm 14:21:48 Wire moved by DX = -1 cm 14:21:56 X0 = -4 cm, dx = -1 cm, VT = -5.394249E-03 VS 14:21:57 Wire moved to X = -4.5 cm 14:22:02 Wire moved by DX = 1 cm 14:22:10 X0 = -4 cm, dx = 1 cm, VT = 5.539053E-03 VS 14:22:11 Wire moved to X = -3.5 cm 14:22:15 Wire moved by DX = -1 cm 14:22:24 X0 = -4 cm, dx = -1 cm, VT = -5.499839E-03 VS 14:22:25 Wire moved to X = -4.5 cm 14:22:29 Wire moved by DX = 1 cm 14:22:38 X0 = -4 cm, dx = 1 cm, VT = 5.497148E-03 VS 14:22:39 Wire moved to X = -3.5 cm 14:22:43 Wire moved by DX = -1 cm 14:22:52 X0 = -4 cm, dx = -1 cm, VT = -5.429601E-03 VS 14:22:53 Wire moved to X = -4.5 cm 14:22:57 Wire moved by DX = 1 cm 14:23:06 X0 = -4 cm, dx = 1 cm, VT = 5.464697E-03 VS 14:23:07 Wire moved to X = -3.5 cm 14:23:11 Wire moved by DX = -1 cm 14:23:20 X0 = -4 cm, dx = -1 cm, VT = -5.452961E-03 VS 14:23:20 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -4 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 5.473358E-03 +- 2.692767E-05 VS (= Tm^2) 14:23:20 The integrated field strength is BL = 5.473357E-02 +- 2.692767E-04 Tm 14:23:20 Magnet Current Measurement... 14:23:22 Power Supply 1 Current, Ips = 50.2315 A 14:23:22 Magnet Current, Imag = 50.2315 A 14:23:24 Power Supply 1 Current, Ips = 50.2146 A 14:23:24 Magnet Current, Imag = 50.2146 A 14:23:26 Power Supply 1 Current, Ips = 50.22324 A 14:23:26 Magnet Current, Imag = 50.22324 A 14:23:28 Power Supply 1 Current, Ips = 50.23588 A 14:23:28 Magnet Current, Imag = 50.23588 A 14:23:28 Magnet Current Measurement: Imag = 50.22631 +- 8.139589E-03 A 14:23:28 Integrated Voltage Measurement... 14:23:32 Wire moved to X = -3.5 cm 14:23:37 Wire moved by DX = 1 cm 14:23:45 X0 = -3 cm, dx = 1 cm, VT = 5.494889E-03 VS 14:23:46 Wire moved to X = -2.5 cm 14:23:51 Wire moved by DX = -1 cm 14:23:59 X0 = -3 cm, dx = -1 cm, VT = -5.494679E-03 VS 14:24:00 Wire moved to X = -3.5 cm 14:24:05 Wire moved by DX = 1 cm 14:24:13 X0 = -3 cm, dx = 1 cm, VT = 5.509789E-03 VS 14:24:14 Wire moved to X = -2.5 cm 14:24:19 Wire moved by DX = -1 cm 14:24:27 X0 = -3 cm, dx = -1 cm, VT = -5.470735E-03 VS 14:24:28 Wire moved to X = -3.5 cm 14:24:33 Wire moved by DX = 1 cm 14:24:41 X0 = -3 cm, dx = 1 cm, VT = 5.558532E-03 VS 14:24:42 Wire moved to X = -2.5 cm 14:24:47 Wire moved by DX = -1 cm 14:24:55 X0 = -3 cm, dx = -1 cm, VT = -5.472213E-03 VS 14:24:56 Wire moved to X = -3.5 cm 14:25:01 Wire moved by DX = 1 cm 14:25:09 X0 = -3 cm, dx = 1 cm, VT = 5.51472E-03 VS 14:25:10 Wire moved to X = -2.5 cm 14:25:15 Wire moved by DX = -1 cm 14:25:23 X0 = -3 cm, dx = -1 cm, VT = -5.46187E-03 VS 14:25:23 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -3 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 5.497179E-03 +- 1.076452E-05 VS (= Tm^2) 14:25:23 The integrated field strength is BL = 5.497178E-02 +- 1.076452E-04 Tm 14:25:23 Magnet Current Measurement... 14:25:25 Power Supply 1 Current, Ips = 50.23328 A 14:25:25 Magnet Current, Imag = 50.23328 A 14:25:27 Power Supply 1 Current, Ips = 50.23352 A 14:25:27 Magnet Current, Imag = 50.23352 A 14:25:29 Power Supply 1 Current, Ips = 50.20736 A 14:25:29 Magnet Current, Imag = 50.20736 A 14:25:31 Power Supply 1 Current, Ips = 50.24224 A 14:25:31 Magnet Current, Imag = 50.24224 A 14:25:31 Magnet Current Measurement: Imag = 50.2291 +- 1.306097E-02 A 14:25:31 Integrated Voltage Measurement... 14:25:35 Wire moved to X = -2.5 cm 14:25:39 Wire moved by DX = 1 cm 14:25:47 X0 = -2 cm, dx = 1 cm, VT = 5.536352E-03 VS 14:25:48 Wire moved to X = -1.5 cm 14:25:53 Wire moved by DX = -1 cm 14:26:01 X0 = -2 cm, dx = -1 cm, VT = -5.440344E-03 VS 14:26:02 Wire moved to X = -2.5 cm 14:26:07 Wire moved by DX = 1 cm 14:26:15 X0 = -2 cm, dx = 1 cm, VT = 5.53174E-03 VS 14:26:16 Wire moved to X = -1.5 cm 14:26:21 Wire moved by DX = -1 cm 14:26:29 X0 = -2 cm, dx = -1 cm, VT = -5.484524E-03 VS 14:26:30 Wire moved to X = -2.5 cm 14:26:35 Wire moved by DX = 1 cm 14:26:43 X0 = -2 cm, dx = 1 cm, VT = 5.496517E-03 VS 14:26:44 Wire moved to X = -1.5 cm 14:26:49 Wire moved by DX = -1 cm 14:26:57 X0 = -2 cm, dx = -1 cm, VT = -5.49475E-03 VS 14:26:58 Wire moved to X = -2.5 cm 14:27:03 Wire moved by DX = 1 cm 14:27:11 X0 = -2 cm, dx = 1 cm, VT = 5.543856E-03 VS 14:27:12 Wire moved to X = -1.5 cm 14:27:17 Wire moved by DX = -1 cm 14:27:25 X0 = -2 cm, dx = -1 cm, VT = -5.444914E-03 VS 14:27:25 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -2 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 5.496625E-03 +- 7.192234E-06 VS (= Tm^2) 14:27:25 The integrated field strength is BL = 5.496625E-02 +- 7.192234E-05 Tm 14:27:25 Magnet Current Measurement... 14:27:27 Power Supply 1 Current, Ips = 50.25704 A 14:27:27 Magnet Current, Imag = 50.25704 A 14:27:29 Power Supply 1 Current, Ips = 50.213 A 14:27:29 Magnet Current, Imag = 50.213 A 14:27:31 Power Supply 1 Current, Ips = 50.22878 A 14:27:31 Magnet Current, Imag = 50.22878 A 14:27:33 Power Supply 1 Current, Ips = 50.22352 A 14:27:33 Magnet Current, Imag = 50.22352 A 14:27:33 Magnet Current Measurement: Imag = 50.23058 +- 1.629783E-02 A 14:27:33 Integrated Voltage Measurement... 14:27:38 Wire moved to X = -1.5 cm 14:27:42 Wire moved by DX = 1 cm 14:27:50 X0 = -1 cm, dx = 1 cm, VT = 5.544298E-03 VS 14:27:52 Wire moved to X = -.5 cm 14:27:56 Wire moved by DX = -1 cm 14:28:04 X0 = -1 cm, dx = -1 cm, VT = -5.448968E-03 VS 14:28:06 Wire moved to X = -1.5 cm 14:28:10 Wire moved by DX = 1 cm 14:28:18 X0 = -1 cm, dx = 1 cm, VT = 5.543335E-03 VS 14:28:20 Wire moved to X = -.5 cm 14:28:24 Wire moved by DX = -1 cm 14:28:32 X0 = -1 cm, dx = -1 cm, VT = -5.492645E-03 VS 14:28:34 Wire moved to X = -1.5 cm 14:28:38 Wire moved by DX = 1 cm 14:28:46 X0 = -1 cm, dx = 1 cm, VT = 5.498571E-03 VS 14:28:48 Wire moved to X = -.5 cm 14:28:52 Wire moved by DX = -1 cm 14:29:00 X0 = -1 cm, dx = -1 cm, VT = -5.449332E-03 VS 14:29:02 Wire moved to X = -1.5 cm 14:29:06 Wire moved by DX = 1 cm 14:29:14 X0 = -1 cm, dx = 1 cm, VT = 5.519723E-03 VS 14:29:16 Wire moved to X = -.5 cm 14:29:20 Wire moved by DX = -1 cm 14:29:28 X0 = -1 cm, dx = -1 cm, VT = -5.416771E-03 VS 14:29:28 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -1 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 5.489205E-03 +- 1.972084E-05 VS (= Tm^2) 14:29:28 The integrated field strength is BL = 5.489206E-02 +- 1.972084E-04 Tm 14:29:29 Magnet Current Measurement... 14:29:31 Power Supply 1 Current, Ips = 50.23516 A 14:29:31 Magnet Current, Imag = 50.23516 A 14:29:32 Power Supply 1 Current, Ips = 50.20934 A 14:29:33 Magnet Current, Imag = 50.20934 A 14:29:34 Power Supply 1 Current, Ips = 50.2292 A 14:29:34 Magnet Current, Imag = 50.2292 A 14:29:36 Power Supply 1 Current, Ips = 50.26064 A 14:29:36 Magnet Current, Imag = 50.26064 A 14:29:36 Magnet Current Measurement: Imag = 50.23359 +- 1.831336E-02 A 14:29:36 Integrated Voltage Measurement... 14:29:40 Wire moved to X = -.5 cm 14:29:44 Wire moved by DX = 1 cm 14:29:53 X0 = 0 cm, dx = 1 cm, VT = 5.506513E-03 VS 14:29:54 Wire moved to X = .5 cm 14:29:58 Wire moved by DX = -1 cm 14:30:06 X0 = 0 cm, dx = -1 cm, VT = -5.441972E-03 VS 14:30:08 Wire moved to X = -.5 cm 14:30:12 Wire moved by DX = 1 cm 14:30:21 X0 = 0 cm, dx = 1 cm, VT = 5.550991E-03 VS 14:30:22 Wire moved to X = .5 cm 14:30:26 Wire moved by DX = -1 cm 14:30:34 X0 = 0 cm, dx = -1 cm, VT = -5.412249E-03 VS 14:30:36 Wire moved to X = -.5 cm 14:30:40 Wire moved by DX = 1 cm 14:30:48 X0 = 0 cm, dx = 1 cm, VT = 5.541244E-03 VS 14:30:50 Wire moved to X = .5 cm 14:30:54 Wire moved by DX = -1 cm 14:31:03 X0 = 0 cm, dx = -1 cm, VT = -5.458664E-03 VS 14:31:04 Wire moved to X = -.5 cm 14:31:08 Wire moved by DX = 1 cm 14:31:17 X0 = 0 cm, dx = 1 cm, VT = 5.523268E-03 VS 14:31:18 Wire moved to X = .5 cm 14:31:22 Wire moved by DX = -1 cm 14:31:31 X0 = 0 cm, dx = -1 cm, VT = -5.448517E-03 VS 14:31:31 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 5.485428E-03 +- 9.365448E-06 VS (= Tm^2) 14:31:31 The integrated field strength is BL = 5.485427E-02 +- 9.365448E-05 Tm 14:31:31 Magnet Current Measurement... 14:31:33 Power Supply 1 Current, Ips = 50.2343 A 14:31:33 Magnet Current, Imag = 50.2343 A 14:31:35 Power Supply 1 Current, Ips = 50.21724 A 14:31:35 Magnet Current, Imag = 50.21724 A 14:31:37 Power Supply 1 Current, Ips = 50.23316 A 14:31:37 Magnet Current, Imag = 50.23316 A 14:31:39 Power Supply 1 Current, Ips = 50.23022 A 14:31:39 Magnet Current, Imag = 50.23022 A 14:31:39 Magnet Current Measurement: Imag = 50.22873 +- 6.798446E-03 A 14:31:39 Integrated Voltage Measurement... 14:31:42 Wire moved to X = .5 cm 14:31:47 Wire moved by DX = 1 cm 14:31:55 X0 = 1 cm, dx = 1 cm, VT = 5.522403E-03 VS 14:31:56 Wire moved to X = 1.5 cm 14:32:01 Wire moved by DX = -1 cm 14:32:09 X0 = 1 cm, dx = -1 cm, VT = -5.488339E-03 VS 14:32:10 Wire moved to X = .5 cm 14:32:14 Wire moved by DX = 1 cm 14:32:23 X0 = 1 cm, dx = 1 cm, VT = 5.551166E-03 VS 14:32:24 Wire moved to X = 1.5 cm 14:32:28 Wire moved by DX = -1 cm 14:32:37 X0 = 1 cm, dx = -1 cm, VT = -5.465051E-03 VS 14:32:38 Wire moved to X = .5 cm 14:32:42 Wire moved by DX = 1 cm 14:32:50 X0 = 1 cm, dx = 1 cm, VT = 5.56278E-03 VS 14:32:52 Wire moved to X = 1.5 cm 14:32:56 Wire moved by DX = -1 cm 14:33:04 X0 = 1 cm, dx = -1 cm, VT = -5.457945E-03 VS 14:33:06 Wire moved to X = .5 cm 14:33:10 Wire moved by DX = 1 cm 14:33:18 X0 = 1 cm, dx = 1 cm, VT = 5.551273E-03 VS 14:33:20 Wire moved to X = 1.5 cm 14:33:24 Wire moved by DX = -1 cm 14:33:32 X0 = 1 cm, dx = -1 cm, VT = -5.454701E-03 VS 14:33:32 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 1 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 5.506707E-03 +- 2.781697E-06 VS (= Tm^2) 14:33:32 The integrated field strength is BL = 5.506707E-02 +- 2.781697E-05 Tm 14:33:33 Magnet Current Measurement... 14:33:34 Power Supply 1 Current, Ips = 50.22281 A 14:33:35 Magnet Current, Imag = 50.22281 A 14:33:36 Power Supply 1 Current, Ips = 50.23912 A 14:33:36 Magnet Current, Imag = 50.23912 A 14:33:38 Power Supply 1 Current, Ips = 50.21654 A 14:33:38 Magnet Current, Imag = 50.21654 A 14:33:40 Power Supply 1 Current, Ips = 50.23214 A 14:33:40 Magnet Current, Imag = 50.23214 A 14:33:40 Magnet Current Measurement: Imag = 50.22765 +- 8.643093E-03 A 14:33:40 Integrated Voltage Measurement... 14:33:44 Wire moved to X = 1.5 cm 14:33:48 Wire moved by DX = 1 cm 14:33:56 X0 = 2 cm, dx = 1 cm, VT = 5.544706E-03 VS 14:33:58 Wire moved to X = 2.5 cm 14:34:02 Wire moved by DX = -1 cm 14:34:10 X0 = 2 cm, dx = -1 cm, VT = -5.456814E-03 VS 14:34:12 Wire moved to X = 1.5 cm 14:34:16 Wire moved by DX = 1 cm 14:34:24 X0 = 2 cm, dx = 1 cm, VT = 5.50576E-03 VS 14:34:26 Wire moved to X = 2.5 cm 14:34:30 Wire moved by DX = -1 cm 14:34:38 X0 = 2 cm, dx = -1 cm, VT = -5.489297E-03 VS 14:34:40 Wire moved to X = 1.5 cm 14:34:44 Wire moved by DX = 1 cm 14:34:52 X0 = 2 cm, dx = 1 cm, VT = 5.491755E-03 VS 14:34:54 Wire moved to X = 2.5 cm 14:34:58 Wire moved by DX = -1 cm 14:35:06 X0 = 2 cm, dx = -1 cm, VT = -5.486986E-03 VS 14:35:08 Wire moved to X = 1.5 cm 14:35:12 Wire moved by DX = 1 cm 14:35:20 X0 = 2 cm, dx = 1 cm, VT = 5.533558E-03 VS 14:35:22 Wire moved to X = 2.5 cm 14:35:26 Wire moved by DX = -1 cm 14:35:34 X0 = 2 cm, dx = -1 cm, VT = -5.424018E-03 VS 14:35:34 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 2 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 5.491612E-03 +- 8.487723E-06 VS (= Tm^2) 14:35:35 The integrated field strength is BL = 5.491611E-02 +- 8.487723E-05 Tm 14:35:35 Magnet Current Measurement... 14:35:37 Power Supply 1 Current, Ips = 50.23808 A 14:35:37 Magnet Current, Imag = 50.23808 A 14:35:38 Power Supply 1 Current, Ips = 50.21012 A 14:35:39 Magnet Current, Imag = 50.21012 A 14:35:40 Power Supply 1 Current, Ips = 50.22586 A 14:35:40 Magnet Current, Imag = 50.22586 A 14:35:42 Power Supply 1 Current, Ips = 50.2331 A 14:35:42 Magnet Current, Imag = 50.2331 A 14:35:42 Magnet Current Measurement: Imag = 50.22679 +- 1.055975E-02 A 14:35:42 Integrated Voltage Measurement... 14:35:46 Wire moved to X = 2.5 cm 14:35:50 Wire moved by DX = 1 cm 14:35:58 X0 = 3 cm, dx = 1 cm, VT = 5.563685E-03 VS 14:36:00 Wire moved to X = 3.5 cm 14:36:04 Wire moved by DX = -1 cm 14:36:12 X0 = 3 cm, dx = -1 cm, VT = -5.434518E-03 VS 14:36:14 Wire moved to X = 2.5 cm 14:36:18 Wire moved by DX = 1 cm 14:36:26 X0 = 3 cm, dx = 1 cm, VT = 5.554821E-03 VS 14:36:28 Wire moved to X = 3.5 cm 14:36:32 Wire moved by DX = -1 cm 14:36:40 X0 = 3 cm, dx = -1 cm, VT = -5.451698E-03 VS 14:36:42 Wire moved to X = 2.5 cm 14:36:46 Wire moved by DX = 1 cm 14:36:54 X0 = 3 cm, dx = 1 cm, VT = 5.532638E-03 VS 14:36:55 Wire moved to X = 3.5 cm 14:37:00 Wire moved by DX = -1 cm 14:37:08 X0 = 3 cm, dx = -1 cm, VT = -5.449369E-03 VS 14:37:09 Wire moved to X = 2.5 cm 14:37:14 Wire moved by DX = 1 cm 14:37:22 X0 = 3 cm, dx = 1 cm, VT = 5.563769E-03 VS 14:37:23 Wire moved to X = 3.5 cm 14:37:28 Wire moved by DX = -1 cm 14:37:36 X0 = 3 cm, dx = -1 cm, VT = -5.435072E-03 VS 14:37:36 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 3 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 5.498196E-03 +- 4.463569E-06 VS (= Tm^2) 14:37:36 The integrated field strength is BL = 5.498197E-02 +- 4.463569E-05 Tm 14:37:36 Magnet Current Measurement... 14:37:38 Power Supply 1 Current, Ips = 50.19738 A 14:37:38 Magnet Current, Imag = 50.19738 A 14:37:40 Power Supply 1 Current, Ips = 50.23294 A 14:37:40 Magnet Current, Imag = 50.23294 A 14:37:42 Power Supply 1 Current, Ips = 50.23418 A 14:37:42 Magnet Current, Imag = 50.23418 A 14:37:44 Power Supply 1 Current, Ips = 50.23114 A 14:37:44 Magnet Current, Imag = 50.23114 A 14:37:44 Magnet Current Measurement: Imag = 50.22391 +- 1.535535E-02 A 14:37:44 Integrated Voltage Measurement... 14:37:48 Wire moved to X = 3.5 cm 14:37:53 Wire moved by DX = 1 cm 14:38:01 X0 = 4 cm, dx = 1 cm, VT = 5.563139E-03 VS 14:38:02 Wire moved to X = 4.5 cm 14:38:07 Wire moved by DX = -1 cm 14:38:15 X0 = 4 cm, dx = -1 cm, VT = -5.426476E-03 VS 14:38:16 Wire moved to X = 3.5 cm 14:38:21 Wire moved by DX = 1 cm 14:38:29 X0 = 4 cm, dx = 1 cm, VT = 5.546698E-03 VS 14:38:30 Wire moved to X = 4.5 cm 14:38:35 Wire moved by DX = -1 cm 14:38:43 X0 = 4 cm, dx = -1 cm, VT = -5.464958E-03 VS 14:38:44 Wire moved to X = 3.5 cm 14:38:48 Wire moved by DX = 1 cm 14:38:57 X0 = 4 cm, dx = 1 cm, VT = 5.52607E-03 VS 14:38:58 Wire moved to X = 4.5 cm 14:39:02 Wire moved by DX = -1 cm 14:39:11 X0 = 4 cm, dx = -1 cm, VT = -5.473367E-03 VS 14:39:12 Wire moved to X = 3.5 cm 14:39:16 Wire moved by DX = 1 cm 14:39:25 X0 = 4 cm, dx = 1 cm, VT = 5.529427E-03 VS 14:39:26 Wire moved to X = 4.5 cm 14:39:30 Wire moved by DX = -1 cm 14:39:39 X0 = 4 cm, dx = -1 cm, VT = -5.471728E-03 VS 14:39:39 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 4 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 5.500233E-03 +- 3.909012E-06 VS (= Tm^2) 14:39:39 The integrated field strength is BL = 5.500233E-02 +- 3.909012E-05 Tm 14:39:39 Magnet Current Measurement... 14:39:41 Power Supply 1 Current, Ips = 50.21276 A 14:39:41 Magnet Current, Imag = 50.21276 A 14:39:43 Power Supply 1 Current, Ips = 50.21838 A 14:39:43 Magnet Current, Imag = 50.21838 A 14:39:45 Power Supply 1 Current, Ips = 50.2176 A 14:39:45 Magnet Current, Imag = 50.2176 A 14:39:46 Power Supply 1 Current, Ips = 50.24436 A 14:39:47 Magnet Current, Imag = 50.24436 A 14:39:47 Magnet Current Measurement: Imag = 50.22327 +- 1.236317E-02 A 14:39:47 Integrated Voltage Measurement... 14:39:50 Wire moved to X = 4.5 cm 14:39:54 Wire moved by DX = 1 cm 14:40:03 X0 = 5 cm, dx = 1 cm, VT = 5.500272E-03 VS 14:40:04 Wire moved to X = 5.5 cm 14:40:08 Wire moved by DX = -1 cm 14:40:17 X0 = 5 cm, dx = -1 cm, VT = -5.490659E-03 VS 14:40:18 Wire moved to X = 4.5 cm 14:40:22 Wire moved by DX = 1 cm 14:40:31 X0 = 5 cm, dx = 1 cm, VT = 5.500556E-03 VS 14:40:32 Wire moved to X = 5.5 cm 14:40:36 Wire moved by DX = -1 cm 14:40:44 X0 = 5 cm, dx = -1 cm, VT = -5.494006E-03 VS 14:40:46 Wire moved to X = 4.5 cm 14:40:50 Wire moved by DX = 1 cm 14:40:58 X0 = 5 cm, dx = 1 cm, VT = 5.50036E-03 VS 14:41:00 Wire moved to X = 5.5 cm 14:41:04 Wire moved by DX = -1 cm 14:41:12 X0 = 5 cm, dx = -1 cm, VT = -5.490726E-03 VS 14:41:14 Wire moved to X = 4.5 cm 14:41:18 Wire moved by DX = 1 cm 14:41:26 X0 = 5 cm, dx = 1 cm, VT = 5.498472E-03 VS 14:41:28 Wire moved to X = 5.5 cm 14:41:32 Wire moved by DX = -1 cm 14:41:40 X0 = 5 cm, dx = -1 cm, VT = -5.489054E-03 VS 14:41:40 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 5 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 5.495513E-03 +- 1.244324E-06 VS (= Tm^2) 14:41:40 The integrated field strength is BL = 5.495513E-02 +- 1.244324E-05 Tm 14:41:53 Wire moved to X = 0 cm 14:44:31 Magnet Current Ramping to 75 A... 14:45:47 Magnet Current Measurement... 14:45:49 Power Supply 1 Current, Ips = 75.676 A 14:45:49 Magnet Current, Imag = 75.676 A 14:45:50 Power Supply 1 Current, Ips = 75.6572 A 14:45:50 Magnet Current, Imag = 75.6572 A 14:45:51 Power Supply 1 Current, Ips = 75.69501 A 14:45:51 Magnet Current, Imag = 75.69501 A 14:45:53 Power Supply 1 Current, Ips = 75.6716 A 14:45:53 Magnet Current, Imag = 75.6716 A 14:45:53 Magnet Current Measurement: Imag = 75.67496 +- 1.350515E-02 A 14:45:53 Integrated Voltage Measurement... 14:46:08 Wire moved to X = -5.5 cm 14:46:13 Wire moved by DX = 1 cm 14:46:21 X0 = -5 cm, dx = 1 cm, VT = 8.233088E-03 VS 14:46:22 Wire moved to X = -4.5 cm 14:46:26 Wire moved by DX = -1 cm 14:46:35 X0 = -5 cm, dx = -1 cm, VT = -8.204372E-03 VS 14:46:36 Wire moved to X = -5.5 cm 14:46:40 Wire moved by DX = 1 cm 14:46:48 X0 = -5 cm, dx = 1 cm, VT = 8.25634E-03 VS 14:46:50 Wire moved to X = -4.5 cm 14:46:54 Wire moved by DX = -1 cm 14:47:02 X0 = -5 cm, dx = -1 cm, VT = -8.241243E-03 VS 14:47:04 Wire moved to X = -5.5 cm 14:47:08 Wire moved by DX = 1 cm 14:47:16 X0 = -5 cm, dx = 1 cm, VT = 8.225325E-03 VS 14:47:18 Wire moved to X = -4.5 cm 14:47:22 Wire moved by DX = -1 cm 14:47:30 X0 = -5 cm, dx = -1 cm, VT = -8.214748E-03 VS 14:47:32 Wire moved to X = -5.5 cm 14:47:36 Wire moved by DX = 1 cm 14:47:44 X0 = -5 cm, dx = 1 cm, VT = 8.282802E-03 VS 14:47:45 Wire moved to X = -4.5 cm 14:47:50 Wire moved by DX = -1 cm 14:47:58 X0 = -5 cm, dx = -1 cm, VT = -8.209411E-03 VS 14:47:58 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -5 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 8.233416E-03 +- 1.407279E-05 VS (= Tm^2) 14:47:58 The integrated field strength is BL = 8.233416E-02 +- 1.407279E-04 Tm 14:47:58 Magnet Current Measurement... 14:48:00 Power Supply 1 Current, Ips = 75.67 A 14:48:00 Magnet Current, Imag = 75.67 A 14:48:01 Power Supply 1 Current, Ips = 75.6934 A 14:48:01 Magnet Current, Imag = 75.6934 A 14:48:03 Power Supply 1 Current, Ips = 75.70741 A 14:48:03 Magnet Current, Imag = 75.70741 A 14:48:04 Power Supply 1 Current, Ips = 75.6782 A 14:48:04 Magnet Current, Imag = 75.6782 A 14:48:04 Magnet Current Measurement: Imag = 75.68725 +- .0143488 A 14:48:04 Integrated Voltage Measurement... 14:48:08 Wire moved to X = -4.5 cm 14:48:12 Wire moved by DX = 1 cm 14:48:20 X0 = -4 cm, dx = 1 cm, VT = 8.216416E-03 VS 14:48:22 Wire moved to X = -3.5 cm 14:48:26 Wire moved by DX = -1 cm 14:48:34 X0 = -4 cm, dx = -1 cm, VT = -8.224455E-03 VS 14:48:36 Wire moved to X = -4.5 cm 14:48:40 Wire moved by DX = 1 cm 14:48:48 X0 = -4 cm, dx = 1 cm, VT = 8.208147E-03 VS 14:48:50 Wire moved to X = -3.5 cm 14:48:54 Wire moved by DX = -1 cm 14:49:02 X0 = -4 cm, dx = -1 cm, VT = -8.246708E-03 VS 14:49:04 Wire moved to X = -4.5 cm 14:49:08 Wire moved by DX = 1 cm 14:49:16 X0 = -4 cm, dx = 1 cm, VT = 8.254859E-03 VS 14:49:18 Wire moved to X = -3.5 cm 14:49:22 Wire moved by DX = -1 cm 14:49:30 X0 = -4 cm, dx = -1 cm, VT = -8.215179E-03 VS 14:49:32 Wire moved to X = -4.5 cm 14:49:36 Wire moved by DX = 1 cm 14:49:44 X0 = -4 cm, dx = 1 cm, VT = 8.22969E-03 VS 14:49:46 Wire moved to X = -3.5 cm 14:49:50 Wire moved by DX = -1 cm 14:49:58 X0 = -4 cm, dx = -1 cm, VT = -8.265037E-03 VS 14:49:58 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -4 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 8.232562E-03 +- 9.981459E-06 VS (= Tm^2) 14:49:58 The integrated field strength is BL = 8.232562E-02 +- 9.981458E-05 Tm 14:49:59 Magnet Current Measurement... 14:50:00 Power Supply 1 Current, Ips = 75.6426 A 14:50:00 Magnet Current, Imag = 75.6426 A 14:50:02 Power Supply 1 Current, Ips = 75.68561 A 14:50:02 Magnet Current, Imag = 75.68561 A 14:50:03 Power Supply 1 Current, Ips = 75.68021 A 14:50:03 Magnet Current, Imag = 75.68021 A 14:50:04 Power Supply 1 Current, Ips = 75.6818 A 14:50:04 Magnet Current, Imag = 75.6818 A 14:50:04 Magnet Current Measurement: Imag = 75.67255 +- 1.740436E-02 A 14:50:05 Integrated Voltage Measurement... 14:50:09 Wire moved to X = -3.5 cm 14:50:13 Wire moved by DX = 1 cm 14:50:22 X0 = -3 cm, dx = 1 cm, VT = 8.212001E-03 VS 14:50:23 Wire moved to X = -2.5 cm 14:50:27 Wire moved by DX = -1 cm 14:50:36 X0 = -3 cm, dx = -1 cm, VT = -8.241626E-03 VS 14:50:37 Wire moved to X = -3.5 cm 14:50:41 Wire moved by DX = 1 cm 14:50:50 X0 = -3 cm, dx = 1 cm, VT = 8.238697E-03 VS 14:50:51 Wire moved to X = -2.5 cm 14:50:55 Wire moved by DX = -1 cm 14:51:04 X0 = -3 cm, dx = -1 cm, VT = -8.223547E-03 VS 14:51:05 Wire moved to X = -3.5 cm 14:51:09 Wire moved by DX = 1 cm 14:51:18 X0 = -3 cm, dx = 1 cm, VT = 8.234674E-03 VS 14:51:19 Wire moved to X = -2.5 cm 14:51:23 Wire moved by DX = -1 cm 14:51:32 X0 = -3 cm, dx = -1 cm, VT = -8.240286E-03 VS 14:51:33 Wire moved to X = -3.5 cm 14:51:37 Wire moved by DX = 1 cm 14:51:46 X0 = -3 cm, dx = 1 cm, VT = 8.205843E-03 VS 14:51:47 Wire moved to X = -2.5 cm 14:51:51 Wire moved by DX = -1 cm 14:52:00 X0 = -3 cm, dx = -1 cm, VT = -8.231204E-03 VS 14:52:00 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -3 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 8.228485E-03 +- 6.890204E-06 VS (= Tm^2) 14:52:00 The integrated field strength is BL = 8.228485E-02 +- 6.890204E-05 Tm 14:52:00 Magnet Current Measurement... 14:52:02 Power Supply 1 Current, Ips = 75.6624 A 14:52:02 Magnet Current, Imag = 75.6624 A 14:52:03 Power Supply 1 Current, Ips = 75.6762 A 14:52:03 Magnet Current, Imag = 75.6762 A 14:52:05 Power Supply 1 Current, Ips = 75.65961 A 14:52:05 Magnet Current, Imag = 75.65961 A 14:52:06 Power Supply 1 Current, Ips = 75.6788 A 14:52:06 Magnet Current, Imag = 75.6788 A 14:52:06 Magnet Current Measurement: Imag = 75.66925 +- 8.358911E-03 A 14:52:06 Integrated Voltage Measurement... 14:52:11 Wire moved to X = -2.5 cm 14:52:15 Wire moved by DX = 1 cm 14:52:23 X0 = -2 cm, dx = 1 cm, VT = 8.259767E-03 VS 14:52:24 Wire moved to X = -1.5 cm 14:52:29 Wire moved by DX = -1 cm 14:52:37 X0 = -2 cm, dx = -1 cm, VT = -8.218893E-03 VS 14:52:38 Wire moved to X = -2.5 cm 14:52:43 Wire moved by DX = 1 cm 14:52:51 X0 = -2 cm, dx = 1 cm, VT = 8.276482E-03 VS 14:52:52 Wire moved to X = -1.5 cm 14:52:57 Wire moved by DX = -1 cm 14:53:05 X0 = -2 cm, dx = -1 cm, VT = -8.157949E-03 VS 14:53:06 Wire moved to X = -2.5 cm 14:53:11 Wire moved by DX = 1 cm 14:53:19 X0 = -2 cm, dx = 1 cm, VT = 8.316491E-03 VS 14:53:20 Wire moved to X = -1.5 cm 14:53:25 Wire moved by DX = -1 cm 14:53:33 X0 = -2 cm, dx = -1 cm, VT = -8.13755E-03 VS 14:53:34 Wire moved to X = -2.5 cm 14:53:39 Wire moved by DX = 1 cm 14:53:47 X0 = -2 cm, dx = 1 cm, VT = 8.313841E-03 VS 14:53:48 Wire moved to X = -1.5 cm 14:53:53 Wire moved by DX = -1 cm 14:54:01 X0 = -2 cm, dx = -1 cm, VT = -8.207742E-03 VS 14:54:01 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -2 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 8.23609E-03 +- 1.627262E-05 VS (= Tm^2) 14:54:01 The integrated field strength is BL = 8.236089E-02 +- 1.627262E-04 Tm 14:54:02 Magnet Current Measurement... 14:54:03 Power Supply 1 Current, Ips = 75.68201 A 14:54:03 Magnet Current, Imag = 75.68201 A 14:54:04 Power Supply 1 Current, Ips = 75.6926 A 14:54:04 Magnet Current, Imag = 75.6926 A 14:54:06 Power Supply 1 Current, Ips = 75.689 A 14:54:06 Magnet Current, Imag = 75.689 A 14:54:07 Power Supply 1 Current, Ips = 75.674 A 14:54:07 Magnet Current, Imag = 75.674 A 14:54:07 Magnet Current Measurement: Imag = 75.6844 +- 7.114514E-03 A 14:54:07 Integrated Voltage Measurement... 14:54:11 Wire moved to X = -1.5 cm 14:54:15 Wire moved by DX = 1 cm 14:54:23 X0 = -1 cm, dx = 1 cm, VT = 8.263878E-03 VS 14:54:25 Wire moved to X = -.5 cm 14:54:29 Wire moved by DX = -1 cm 14:54:37 X0 = -1 cm, dx = -1 cm, VT = -8.186658E-03 VS 14:54:39 Wire moved to X = -1.5 cm 14:54:43 Wire moved by DX = 1 cm 14:54:51 X0 = -1 cm, dx = 1 cm, VT = 8.277692E-03 VS 14:54:53 Wire moved to X = -.5 cm 14:54:57 Wire moved by DX = -1 cm 14:55:05 X0 = -1 cm, dx = -1 cm, VT = -8.230488E-03 VS 14:55:07 Wire moved to X = -1.5 cm 14:55:11 Wire moved by DX = 1 cm 14:55:19 X0 = -1 cm, dx = 1 cm, VT = 8.248817E-03 VS 14:55:21 Wire moved to X = -.5 cm 14:55:25 Wire moved by DX = -1 cm 14:55:33 X0 = -1 cm, dx = -1 cm, VT = -8.213438E-03 VS 14:55:34 Wire moved to X = -1.5 cm 14:55:39 Wire moved by DX = 1 cm 14:55:47 X0 = -1 cm, dx = 1 cm, VT = 8.277818E-03 VS 14:55:48 Wire moved to X = -.5 cm 14:55:53 Wire moved by DX = -1 cm 14:56:01 X0 = -1 cm, dx = -1 cm, VT = -8.181542E-03 VS 14:56:01 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -1 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 8.235041E-03 +- 1.120763E-05 VS (= Tm^2) 14:56:01 The integrated field strength is BL = 8.235041E-02 +- 1.120763E-04 Tm 14:56:02 Magnet Current Measurement... 14:56:03 Power Supply 1 Current, Ips = 75.67741 A 14:56:03 Magnet Current, Imag = 75.67741 A 14:56:04 Power Supply 1 Current, Ips = 75.6616 A 14:56:05 Magnet Current, Imag = 75.6616 A 14:56:06 Power Supply 1 Current, Ips = 75.673 A 14:56:06 Magnet Current, Imag = 75.673 A 14:56:07 Power Supply 1 Current, Ips = 75.6624 A 14:56:07 Magnet Current, Imag = 75.6624 A 14:56:07 Magnet Current Measurement: Imag = 75.6686 +- 6.790095E-03 A 14:56:08 Integrated Voltage Measurement... 14:56:11 Wire moved to X = -.5 cm 14:56:15 Wire moved by DX = 1 cm 14:56:24 X0 = 0 cm, dx = 1 cm, VT = 8.266436E-03 VS 14:56:25 Wire moved to X = .5 cm 14:56:29 Wire moved by DX = -1 cm 14:56:38 X0 = 0 cm, dx = -1 cm, VT = -8.21412E-03 VS 14:56:39 Wire moved to X = -.5 cm 14:56:43 Wire moved by DX = 1 cm 14:56:52 X0 = 0 cm, dx = 1 cm, VT = 8.23849E-03 VS 14:56:53 Wire moved to X = .5 cm 14:56:57 Wire moved by DX = -1 cm 14:57:06 X0 = 0 cm, dx = -1 cm, VT = -8.247628E-03 VS 14:57:07 Wire moved to X = -.5 cm 14:57:11 Wire moved by DX = 1 cm 14:57:20 X0 = 0 cm, dx = 1 cm, VT = 8.241853E-03 VS 14:57:21 Wire moved to X = .5 cm 14:57:25 Wire moved by DX = -1 cm 14:57:34 X0 = 0 cm, dx = -1 cm, VT = -8.235729E-03 VS 14:57:35 Wire moved to X = -.5 cm 14:57:39 Wire moved by DX = 1 cm 14:57:48 X0 = 0 cm, dx = 1 cm, VT = 8.224986E-03 VS 14:57:49 Wire moved to X = .5 cm 14:57:53 Wire moved by DX = -1 cm 14:58:02 X0 = 0 cm, dx = -1 cm, VT = -8.255389E-03 VS 14:58:02 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 8.240579E-03 +- 1.548539E-06 VS (= Tm^2) 14:58:02 The integrated field strength is BL = 8.240579E-02 +- 1.548539E-05 Tm 14:58:02 Magnet Current Measurement... 14:58:03 Power Supply 1 Current, Ips = 75.653 A 14:58:04 Magnet Current, Imag = 75.653 A 14:58:05 Power Supply 1 Current, Ips = 75.6634 A 14:58:05 Magnet Current, Imag = 75.6634 A 14:58:06 Power Supply 1 Current, Ips = 75.663 A 14:58:06 Magnet Current, Imag = 75.663 A 14:58:08 Power Supply 1 Current, Ips = 75.67 A 14:58:08 Magnet Current, Imag = 75.67 A 14:58:08 Magnet Current Measurement: Imag = 75.66235 +- 6.071332E-03 A 14:58:08 Integrated Voltage Measurement... 14:58:11 Wire moved to X = .5 cm 14:58:16 Wire moved by DX = 1 cm 14:58:24 X0 = 1 cm, dx = 1 cm, VT = 8.272259E-03 VS 14:58:25 Wire moved to X = 1.5 cm 14:58:30 Wire moved by DX = -1 cm 14:58:38 X0 = 1 cm, dx = -1 cm, VT = -8.213353E-03 VS 14:58:39 Wire moved to X = .5 cm 14:58:44 Wire moved by DX = 1 cm 14:58:52 X0 = 1 cm, dx = 1 cm, VT = 8.283369E-03 VS 14:58:53 Wire moved to X = 1.5 cm 14:58:58 Wire moved by DX = -1 cm 14:59:06 X0 = 1 cm, dx = -1 cm, VT = -8.199533E-03 VS 14:59:07 Wire moved to X = .5 cm 14:59:12 Wire moved by DX = 1 cm 14:59:20 X0 = 1 cm, dx = 1 cm, VT = 8.264823E-03 VS 14:59:21 Wire moved to X = 1.5 cm 14:59:26 Wire moved by DX = -1 cm 14:59:34 X0 = 1 cm, dx = -1 cm, VT = -8.199916E-03 VS 14:59:35 Wire moved to X = .5 cm 14:59:40 Wire moved by DX = 1 cm 14:59:48 X0 = 1 cm, dx = 1 cm, VT = 8.275973E-03 VS 14:59:49 Wire moved to X = 1.5 cm 14:59:54 Wire moved by DX = -1 cm 15:00:02 X0 = 1 cm, dx = -1 cm, VT = -8.203135E-03 VS 15:00:02 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 1 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 8.239046E-03 +- 4.023338E-06 VS (= Tm^2) 15:00:02 The integrated field strength is BL = 8.239046E-02 +- 4.023338E-05 Tm 15:00:03 Magnet Current Measurement... 15:00:04 Power Supply 1 Current, Ips = 75.6728 A 15:00:04 Magnet Current, Imag = 75.6728 A 15:00:05 Power Supply 1 Current, Ips = 75.696 A 15:00:06 Magnet Current, Imag = 75.696 A 15:00:07 Power Supply 1 Current, Ips = 75.67561 A 15:00:07 Magnet Current, Imag = 75.67561 A 15:00:08 Power Supply 1 Current, Ips = 75.684 A 15:00:08 Magnet Current, Imag = 75.684 A 15:00:09 Magnet Current Measurement: Imag = 75.6821 +- 9.020648E-03 A 15:00:09 Integrated Voltage Measurement... 15:00:13 Wire moved to X = 1.5 cm 15:00:17 Wire moved by DX = 1 cm 15:00:26 X0 = 2 cm, dx = 1 cm, VT = 8.279592E-03 VS 15:00:27 Wire moved to X = 2.5 cm 15:00:31 Wire moved by DX = -1 cm 15:00:40 X0 = 2 cm, dx = -1 cm, VT = -8.20244E-03 VS 15:00:41 Wire moved to X = 1.5 cm 15:00:45 Wire moved by DX = 1 cm 15:00:54 X0 = 2 cm, dx = 1 cm, VT = 8.271043E-03 VS 15:00:55 Wire moved to X = 2.5 cm 15:00:59 Wire moved by DX = -1 cm 15:01:08 X0 = 2 cm, dx = -1 cm, VT = -8.238797E-03 VS 15:01:09 Wire moved to X = 1.5 cm 15:01:14 Wire moved by DX = 1 cm 15:01:22 X0 = 2 cm, dx = 1 cm, VT = 8.25538E-03 VS 15:01:23 Wire moved to X = 2.5 cm 15:01:28 Wire moved by DX = -1 cm 15:01:36 X0 = 2 cm, dx = -1 cm, VT = -8.224401E-03 VS 15:01:37 Wire moved to X = 1.5 cm 15:01:42 Wire moved by DX = 1 cm 15:01:50 X0 = 2 cm, dx = 1 cm, VT = 8.253072E-03 VS 15:01:51 Wire moved to X = 2.5 cm 15:01:56 Wire moved by DX = -1 cm 15:02:04 X0 = 2 cm, dx = -1 cm, VT = -8.22704E-03 VS 15:02:04 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 2 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 8.243971E-03 +- 6.336194E-06 VS (= Tm^2) 15:02:04 The integrated field strength is BL = 8.243971E-02 +- 6.336194E-05 Tm 15:02:04 Magnet Current Measurement... 15:02:06 Power Supply 1 Current, Ips = 75.7028 A 15:02:06 Magnet Current, Imag = 75.7028 A 15:02:07 Power Supply 1 Current, Ips = 75.6846 A 15:02:07 Magnet Current, Imag = 75.6846 A 15:02:09 Power Supply 1 Current, Ips = 75.6866 A 15:02:09 Magnet Current, Imag = 75.6866 A 15:02:10 Power Supply 1 Current, Ips = 75.69621 A 15:02:10 Magnet Current, Imag = 75.69621 A 15:02:10 Magnet Current Measurement: Imag = 75.69255 +- 7.364692E-03 A 15:02:10 Integrated Voltage Measurement... 15:02:15 Wire moved to X = 2.5 cm 15:02:19 Wire moved by DX = 1 cm 15:02:27 X0 = 3 cm, dx = 1 cm, VT = 8.26749E-03 VS 15:02:29 Wire moved to X = 3.5 cm 15:02:33 Wire moved by DX = -1 cm 15:02:41 X0 = 3 cm, dx = -1 cm, VT = -8.235671E-03 VS 15:02:43 Wire moved to X = 2.5 cm 15:02:47 Wire moved by DX = 1 cm 15:02:55 X0 = 3 cm, dx = 1 cm, VT = 8.254056E-03 VS 15:02:57 Wire moved to X = 3.5 cm 15:03:01 Wire moved by DX = -1 cm 15:03:09 X0 = 3 cm, dx = -1 cm, VT = -8.225941E-03 VS 15:03:11 Wire moved to X = 2.5 cm 15:03:15 Wire moved by DX = 1 cm 15:03:23 X0 = 3 cm, dx = 1 cm, VT = 8.238764E-03 VS 15:03:25 Wire moved to X = 3.5 cm 15:03:29 Wire moved by DX = -1 cm 15:03:37 X0 = 3 cm, dx = -1 cm, VT = -8.229638E-03 VS 15:03:39 Wire moved to X = 2.5 cm 15:03:43 Wire moved by DX = 1 cm 15:03:51 X0 = 3 cm, dx = 1 cm, VT = 8.254056E-03 VS 15:03:53 Wire moved to X = 3.5 cm 15:03:57 Wire moved by DX = -1 cm 15:04:05 X0 = 3 cm, dx = -1 cm, VT = -8.214081E-03 VS 15:04:05 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 3 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 8.239962E-03 +- 7.122294E-06 VS (= Tm^2) 15:04:06 The integrated field strength is BL = 8.239962E-02 +- 7.122294E-05 Tm 15:04:06 Magnet Current Measurement... 15:04:07 Power Supply 1 Current, Ips = 75.68201 A 15:04:07 Magnet Current, Imag = 75.68201 A 15:04:09 Power Supply 1 Current, Ips = 75.6778 A 15:04:09 Magnet Current, Imag = 75.6778 A 15:04:10 Power Supply 1 Current, Ips = 75.6844 A 15:04:10 Magnet Current, Imag = 75.6844 A 15:04:12 Power Supply 1 Current, Ips = 75.69321 A 15:04:12 Magnet Current, Imag = 75.69321 A 15:04:12 Magnet Current Measurement: Imag = 75.68436 +- 5.630241E-03 A 15:04:12 Integrated Voltage Measurement... 15:04:16 Wire moved to X = 3.5 cm 15:04:21 Wire moved by DX = 1 cm 15:04:29 X0 = 4 cm, dx = 1 cm, VT = 8.306942E-03 VS 15:04:30 Wire moved to X = 4.5 cm 15:04:35 Wire moved by DX = -1 cm 15:04:43 X0 = 4 cm, dx = -1 cm, VT = -8.165324E-03 VS 15:04:44 Wire moved to X = 3.5 cm 15:04:49 Wire moved by DX = 1 cm 15:04:57 X0 = 4 cm, dx = 1 cm, VT = 8.33766E-03 VS 15:04:58 Wire moved to X = 4.5 cm 15:05:03 Wire moved by DX = -1 cm 15:05:11 X0 = 4 cm, dx = -1 cm, VT = -8.141304E-03 VS 15:05:12 Wire moved to X = 3.5 cm 15:05:17 Wire moved by DX = 1 cm 15:05:25 X0 = 4 cm, dx = 1 cm, VT = 8.326443E-03 VS 15:05:26 Wire moved to X = 4.5 cm 15:05:31 Wire moved by DX = -1 cm 15:05:39 X0 = 4 cm, dx = -1 cm, VT = -8.177886E-03 VS 15:05:40 Wire moved to X = 3.5 cm 15:05:45 Wire moved by DX = 1 cm 15:05:53 X0 = 4 cm, dx = 1 cm, VT = 8.326962E-03 VS 15:05:54 Wire moved to X = 4.5 cm 15:05:59 Wire moved by DX = -1 cm 15:06:07 X0 = 4 cm, dx = -1 cm, VT = -8.161464E-03 VS 15:06:07 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 4 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 8.242998E-03 +- 6.020731E-06 VS (= Tm^2) 15:06:07 The integrated field strength is BL = 8.242998E-02 +- 6.020731E-05 Tm 15:06:07 Magnet Current Measurement... 15:06:09 Power Supply 1 Current, Ips = 75.6974 A 15:06:09 Magnet Current, Imag = 75.6974 A 15:06:10 Power Supply 1 Current, Ips = 75.68501 A 15:06:10 Magnet Current, Imag = 75.68501 A 15:06:12 Power Supply 1 Current, Ips = 75.657 A 15:06:12 Magnet Current, Imag = 75.657 A 15:06:13 Power Supply 1 Current, Ips = 75.65501 A 15:06:13 Magnet Current, Imag = 75.65501 A 15:06:13 Magnet Current Measurement: Imag = 75.67361 +- 1.815226E-02 A 15:06:13 Integrated Voltage Measurement... 15:06:18 Wire moved to X = 4.5 cm 15:06:22 Wire moved by DX = 1 cm 15:06:30 X0 = 5 cm, dx = 1 cm, VT = 8.338257E-03 VS 15:06:32 Wire moved to X = 5.5 cm 15:06:36 Wire moved by DX = -1 cm 15:06:44 X0 = 5 cm, dx = -1 cm, VT = -8.158009E-03 VS 15:06:46 Wire moved to X = 4.5 cm 15:06:50 Wire moved by DX = 1 cm 15:06:58 X0 = 5 cm, dx = 1 cm, VT = 8.318751E-03 VS 15:06:59 Wire moved to X = 5.5 cm 15:07:04 Wire moved by DX = -1 cm 15:07:12 X0 = 5 cm, dx = -1 cm, VT = -8.181607E-03 VS 15:07:13 Wire moved to X = 4.5 cm 15:07:18 Wire moved by DX = 1 cm 15:07:26 X0 = 5 cm, dx = 1 cm, VT = 8.318165E-03 VS 15:07:27 Wire moved to X = 5.5 cm 15:07:32 Wire moved by DX = -1 cm 15:07:40 X0 = 5 cm, dx = -1 cm, VT = -8.159725E-03 VS 15:07:41 Wire moved to X = 4.5 cm 15:07:46 Wire moved by DX = 1 cm 15:07:54 X0 = 5 cm, dx = 1 cm, VT = 8.325544E-03 VS 15:07:55 Wire moved to X = 5.5 cm 15:08:00 Wire moved by DX = -1 cm 15:08:08 X0 = 5 cm, dx = -1 cm, VT = -8.178573E-03 VS 15:08:08 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 5 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 8.247329E-03 +- 5.0354E-06 VS (= Tm^2) 15:08:08 The integrated field strength is BL = 8.247329E-02 +- 5.0354E-05 Tm 15:08:21 Wire moved to X = 0 cm 15:20:53 Magnet Current Ramping to 85 A... 15:21:42 Magnet Current Measurement... 15:21:44 Power Supply 1 Current, Ips = 85.5626 A 15:21:44 Magnet Current, Imag = 85.5626 A 15:21:45 Power Supply 1 Current, Ips = 85.558 A 15:21:45 Magnet Current, Imag = 85.558 A 15:21:47 Power Supply 1 Current, Ips = 85.56741 A 15:21:47 Magnet Current, Imag = 85.56741 A 15:21:48 Power Supply 1 Current, Ips = 85.569 A 15:21:48 Magnet Current, Imag = 85.569 A 15:21:48 Magnet Current Measurement: Imag = 85.56425 +- 4.310679E-03 A 15:21:48 Integrated Voltage Measurement... 15:22:04 Wire moved to X = -5.5 cm 15:22:08 Wire moved by DX = 1 cm 15:22:16 X0 = -5 cm, dx = 1 cm, VT = 9.326437E-03 VS 15:22:18 Wire moved to X = -4.5 cm 15:22:22 Wire moved by DX = -1 cm 15:22:30 X0 = -5 cm, dx = -1 cm, VT = -.0092394 VS 15:22:32 Wire moved to X = -5.5 cm 15:22:36 Wire moved by DX = 1 cm 15:22:44 X0 = -5 cm, dx = 1 cm, VT = 9.291327E-03 VS 15:22:46 Wire moved to X = -4.5 cm 15:22:50 Wire moved by DX = -1 cm 15:22:58 X0 = -5 cm, dx = -1 cm, VT = -9.254301E-03 VS 15:23:00 Wire moved to X = -5.5 cm 15:23:04 Wire moved by DX = 1 cm 15:23:12 X0 = -5 cm, dx = 1 cm, VT = 9.42182E-03 VS 15:23:14 Wire moved to X = -4.5 cm 15:23:18 Wire moved by DX = -1 cm 15:23:26 X0 = -5 cm, dx = -1 cm, VT = -9.24359E-03 VS 15:23:28 Wire moved to X = -5.5 cm 15:23:32 Wire moved by DX = 1 cm 15:23:40 X0 = -5 cm, dx = 1 cm, VT = 9.352197E-03 VS 15:23:42 Wire moved to X = -4.5 cm 15:23:46 Wire moved by DX = -1 cm 15:23:54 X0 = -5 cm, dx = -1 cm, VT = -9.201301E-03 VS 15:23:55 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -5 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 9.291297E-03 +- 2.417695E-05 VS (= Tm^2) 15:23:55 The integrated field strength is BL = 9.291297E-02 +- 2.417695E-04 Tm 15:23:55 Magnet Current Measurement... 15:23:56 Power Supply 1 Current, Ips = 85.58521 A 15:23:56 Magnet Current, Imag = 85.58521 A 15:23:58 Power Supply 1 Current, Ips = 85.5642 A 15:23:58 Magnet Current, Imag = 85.5642 A 15:23:59 Power Supply 1 Current, Ips = 85.5714 A 15:23:59 Magnet Current, Imag = 85.5714 A 15:24:01 Power Supply 1 Current, Ips = 85.58801 A 15:24:01 Magnet Current, Imag = 85.58801 A 15:24:01 Magnet Current Measurement: Imag = 85.57721 +- 9.790237E-03 A 15:24:01 Integrated Voltage Measurement... 15:24:04 Wire moved to X = -4.5 cm 15:24:09 Wire moved by DX = 1 cm 15:24:17 X0 = -4 cm, dx = 1 cm, VT = 9.322897E-03 VS 15:24:18 Wire moved to X = -3.5 cm 15:24:23 Wire moved by DX = -1 cm 15:24:31 X0 = -4 cm, dx = -1 cm, VT = -9.338415E-03 VS 15:24:32 Wire moved to X = -4.5 cm 15:24:37 Wire moved by DX = 1 cm 15:24:45 X0 = -4 cm, dx = 1 cm, VT = 9.342659E-03 VS 15:24:46 Wire moved to X = -3.5 cm 15:24:51 Wire moved by DX = -1 cm 15:24:59 X0 = -4 cm, dx = -1 cm, VT = -9.276932E-03 VS 15:25:00 Wire moved to X = -4.5 cm 15:25:04 Wire moved by DX = 1 cm 15:25:13 X0 = -4 cm, dx = 1 cm, VT = 9.399562E-03 VS 15:25:14 Wire moved to X = -3.5 cm 15:25:18 Wire moved by DX = -1 cm 15:25:27 X0 = -4 cm, dx = -1 cm, VT = -9.285511E-03 VS 15:25:28 Wire moved to X = -4.5 cm 15:25:32 Wire moved by DX = 1 cm 15:25:41 X0 = -4 cm, dx = 1 cm, VT = 9.322655E-03 VS 15:25:42 Wire moved to X = -3.5 cm 15:25:46 Wire moved by DX = -1 cm 15:25:54 X0 = -4 cm, dx = -1 cm, VT = -9.242888E-03 VS 15:25:55 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -4 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 9.31644E-03 +- 2.269823E-05 VS (= Tm^2) 15:25:55 The integrated field strength is BL = .0931644 +- 2.269823E-04 Tm 15:25:55 Magnet Current Measurement... 15:25:56 Power Supply 1 Current, Ips = 85.5722 A 15:25:56 Magnet Current, Imag = 85.5722 A 15:25:58 Power Supply 1 Current, Ips = 85.55161 A 15:25:58 Magnet Current, Imag = 85.55161 A 15:25:59 Power Supply 1 Current, Ips = 85.5622 A 15:25:59 Magnet Current, Imag = 85.5622 A 15:26:01 Power Supply 1 Current, Ips = 85.5746 A 15:26:01 Magnet Current, Imag = 85.5746 A 15:26:01 Magnet Current Measurement: Imag = 85.56516 +- 9.099764E-03 A 15:26:01 Integrated Voltage Measurement... 15:26:05 Wire moved to X = -3.5 cm 15:26:10 Wire moved by DX = 1 cm 15:26:18 X0 = -3 cm, dx = 1 cm, VT = 9.304858E-03 VS 15:26:19 Wire moved to X = -2.5 cm 15:26:24 Wire moved by DX = -1 cm 15:26:32 X0 = -3 cm, dx = -1 cm, VT = -9.330573E-03 VS 15:26:33 Wire moved to X = -3.5 cm 15:26:38 Wire moved by DX = 1 cm 15:26:46 X0 = -3 cm, dx = 1 cm, VT = 9.320641E-03 VS 15:26:47 Wire moved to X = -2.5 cm 15:26:52 Wire moved by DX = -1 cm 15:27:00 X0 = -3 cm, dx = -1 cm, VT = -9.299365E-03 VS 15:27:01 Wire moved to X = -3.5 cm 15:27:06 Wire moved by DX = 1 cm 15:27:14 X0 = -3 cm, dx = 1 cm, VT = 9.315737E-03 VS 15:27:15 Wire moved to X = -2.5 cm 15:27:20 Wire moved by DX = -1 cm 15:27:28 X0 = -3 cm, dx = -1 cm, VT = -9.32347E-03 VS 15:27:30 Wire moved to X = -3.5 cm 15:27:34 Wire moved by DX = 1 cm 15:27:42 X0 = -3 cm, dx = 1 cm, VT = 9.280112E-03 VS 15:27:44 Wire moved to X = -2.5 cm 15:27:48 Wire moved by DX = -1 cm 15:27:56 X0 = -3 cm, dx = -1 cm, VT = -9.333348E-03 VS 15:27:56 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -3 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 9.313513E-03 +- 5.317083E-06 VS (= Tm^2) 15:27:56 The integrated field strength is BL = 9.313513E-02 +- 5.317083E-05 Tm 15:27:57 Magnet Current Measurement... 15:27:58 Power Supply 1 Current, Ips = 85.5686 A 15:27:58 Magnet Current, Imag = 85.5686 A 15:27:59 Power Supply 1 Current, Ips = 85.53461 A 15:28:00 Magnet Current, Imag = 85.53461 A 15:28:01 Power Supply 1 Current, Ips = 85.567 A 15:28:01 Magnet Current, Imag = 85.567 A 15:28:02 Power Supply 1 Current, Ips = 85.5788 A 15:28:02 Magnet Current, Imag = 85.5788 A 15:28:03 Magnet Current Measurement: Imag = 85.56226 +- 1.659154E-02 A 15:28:03 Integrated Voltage Measurement... 15:28:06 Wire moved to X = -2.5 cm 15:28:10 Wire moved by DX = 1 cm 15:28:19 X0 = -2 cm, dx = 1 cm, VT = 9.309446E-03 VS 15:28:20 Wire moved to X = -1.5 cm 15:28:24 Wire moved by DX = -1 cm 15:28:33 X0 = -2 cm, dx = -1 cm, VT = -9.31122E-03 VS 15:28:34 Wire moved to X = -2.5 cm 15:28:38 Wire moved by DX = 1 cm 15:28:47 X0 = -2 cm, dx = 1 cm, VT = 9.278293E-03 VS 15:28:48 Wire moved to X = -1.5 cm 15:28:52 Wire moved by DX = -1 cm 15:29:01 X0 = -2 cm, dx = -1 cm, VT = -9.277201E-03 VS 15:29:02 Wire moved to X = -2.5 cm 15:29:06 Wire moved by DX = 1 cm 15:29:15 X0 = -2 cm, dx = 1 cm, VT = 9.312999E-03 VS 15:29:16 Wire moved to X = -1.5 cm 15:29:20 Wire moved by DX = -1 cm 15:29:29 X0 = -2 cm, dx = -1 cm, VT = -9.313299E-03 VS 15:29:30 Wire moved to X = -2.5 cm 15:29:35 Wire moved by DX = 1 cm 15:29:43 X0 = -2 cm, dx = 1 cm, VT = 9.265218E-03 VS 15:29:44 Wire moved to X = -1.5 cm 15:29:48 Wire moved by DX = -1 cm 15:29:57 X0 = -2 cm, dx = -1 cm, VT = -9.308237E-03 VS 15:29:57 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -2 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 9.296989E-03 +- 1.512257E-05 VS (= Tm^2) 15:29:57 The integrated field strength is BL = 9.296989E-02 +- 1.512257E-04 Tm 15:29:57 Magnet Current Measurement... 15:29:59 Power Supply 1 Current, Ips = 85.5694 A 15:29:59 Magnet Current, Imag = 85.5694 A 15:30:00 Power Supply 1 Current, Ips = 85.5602 A 15:30:00 Magnet Current, Imag = 85.5602 A 15:30:01 Power Supply 1 Current, Ips = 85.5402 A 15:30:02 Magnet Current, Imag = 85.5402 A 15:30:03 Power Supply 1 Current, Ips = 85.5348 A 15:30:03 Magnet Current, Imag = 85.5348 A 15:30:03 Magnet Current Measurement: Imag = 85.55115 +- 1.416434E-02 A 15:30:03 Integrated Voltage Measurement... 15:30:07 Wire moved to X = -1.5 cm 15:30:11 Wire moved by DX = 1 cm 15:30:19 X0 = -1 cm, dx = 1 cm, VT = 9.294095E-03 VS 15:30:21 Wire moved to X = -.5 cm 15:30:25 Wire moved by DX = -1 cm 15:30:33 X0 = -1 cm, dx = -1 cm, VT = -9.274653E-03 VS 15:30:35 Wire moved to X = -1.5 cm 15:30:39 Wire moved by DX = 1 cm 15:30:47 X0 = -1 cm, dx = 1 cm, VT = 9.326881E-03 VS 15:30:48 Wire moved to X = -.5 cm 15:30:53 Wire moved by DX = -1 cm 15:31:01 X0 = -1 cm, dx = -1 cm, VT = -9.278713E-03 VS 15:31:02 Wire moved to X = -1.5 cm 15:31:07 Wire moved by DX = 1 cm 15:31:15 X0 = -1 cm, dx = 1 cm, VT = 9.347498E-03 VS 15:31:16 Wire moved to X = -.5 cm 15:31:21 Wire moved by DX = -1 cm 15:31:29 X0 = -1 cm, dx = -1 cm, VT = -9.287954E-03 VS 15:31:30 Wire moved to X = -1.5 cm 15:31:35 Wire moved by DX = 1 cm 15:31:43 X0 = -1 cm, dx = 1 cm, VT = 9.321732E-03 VS 15:31:44 Wire moved to X = -.5 cm 15:31:49 Wire moved by DX = -1 cm 15:31:57 X0 = -1 cm, dx = -1 cm, VT = -9.267325E-03 VS 15:31:57 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -1 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 9.299856E-03 +- 1.220733E-05 VS (= Tm^2) 15:31:57 The integrated field strength is BL = 9.299856E-02 +- 1.220733E-04 Tm 15:31:57 Magnet Current Measurement... 15:31:59 Power Supply 1 Current, Ips = 85.591 A 15:31:59 Magnet Current, Imag = 85.591 A 15:32:00 Power Supply 1 Current, Ips = 85.5866 A 15:32:00 Magnet Current, Imag = 85.5866 A 15:32:01 Power Supply 1 Current, Ips = 85.5586 A 15:32:02 Magnet Current, Imag = 85.5586 A 15:32:03 Power Supply 1 Current, Ips = 85.58221 A 15:32:03 Magnet Current, Imag = 85.58221 A 15:32:03 Magnet Current Measurement: Imag = 85.57961 +- 1.251791E-02 A 15:32:03 Integrated Voltage Measurement... 15:32:07 Wire moved to X = -.5 cm 15:32:11 Wire moved by DX = 1 cm 15:32:19 X0 = 0 cm, dx = 1 cm, VT = 9.351987E-03 VS 15:32:20 Wire moved to X = .5 cm 15:32:25 Wire moved by DX = -1 cm 15:32:33 X0 = 0 cm, dx = -1 cm, VT = -9.269299E-03 VS 15:32:34 Wire moved to X = -.5 cm 15:32:39 Wire moved by DX = 1 cm 15:32:47 X0 = 0 cm, dx = 1 cm, VT = 9.343142E-03 VS 15:32:48 Wire moved to X = .5 cm 15:32:53 Wire moved by DX = -1 cm 15:33:01 X0 = 0 cm, dx = -1 cm, VT = -9.267852E-03 VS 15:33:02 Wire moved to X = -.5 cm 15:33:07 Wire moved by DX = 1 cm 15:33:15 X0 = 0 cm, dx = 1 cm, VT = 9.374863E-03 VS 15:33:16 Wire moved to X = .5 cm 15:33:21 Wire moved by DX = -1 cm 15:33:29 X0 = 0 cm, dx = -1 cm, VT = -9.237586E-03 VS 15:33:30 Wire moved to X = -.5 cm 15:33:35 Wire moved by DX = 1 cm 15:33:43 X0 = 0 cm, dx = 1 cm, VT = 9.379018E-03 VS 15:33:44 Wire moved to X = .5 cm 15:33:48 Wire moved by DX = -1 cm 15:33:57 X0 = 0 cm, dx = -1 cm, VT = -9.215542E-03 VS 15:33:57 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 9.304911E-03 +- 4.826044E-06 VS (= Tm^2) 15:33:57 The integrated field strength is BL = 9.304911E-02 +- 4.826044E-05 Tm 15:33:57 Magnet Current Measurement... 15:33:59 Power Supply 1 Current, Ips = 85.5642 A 15:33:59 Magnet Current, Imag = 85.5642 A 15:34:00 Power Supply 1 Current, Ips = 85.5678 A 15:34:00 Magnet Current, Imag = 85.5678 A 15:34:01 Power Supply 1 Current, Ips = 85.53101 A 15:34:01 Magnet Current, Imag = 85.53101 A 15:34:03 Power Supply 1 Current, Ips = 85.5782 A 15:34:03 Magnet Current, Imag = 85.5782 A 15:34:03 Magnet Current Measurement: Imag = 85.5603 +- 1.767845E-02 A 15:34:03 Integrated Voltage Measurement... 15:34:06 Wire moved to X = .5 cm 15:34:11 Wire moved by DX = 1 cm 15:34:19 X0 = 1 cm, dx = 1 cm, VT = 9.380626E-03 VS 15:34:20 Wire moved to X = 1.5 cm 15:34:25 Wire moved by DX = -1 cm 15:34:33 X0 = 1 cm, dx = -1 cm, VT = -9.23323E-03 VS 15:34:34 Wire moved to X = .5 cm 15:34:39 Wire moved by DX = 1 cm 15:34:47 X0 = 1 cm, dx = 1 cm, VT = 9.362649E-03 VS 15:34:48 Wire moved to X = 1.5 cm 15:34:53 Wire moved by DX = -1 cm 15:35:01 X0 = 1 cm, dx = -1 cm, VT = -9.267059E-03 VS 15:35:02 Wire moved to X = .5 cm 15:35:07 Wire moved by DX = 1 cm 15:35:15 X0 = 1 cm, dx = 1 cm, VT = 9.317834E-03 VS 15:35:16 Wire moved to X = 1.5 cm 15:35:21 Wire moved by DX = -1 cm 15:35:29 X0 = 1 cm, dx = -1 cm, VT = -9.309336E-03 VS 15:35:30 Wire moved to X = .5 cm 15:35:35 Wire moved by DX = 1 cm 15:35:43 X0 = 1 cm, dx = 1 cm, VT = 9.349411E-03 VS 15:35:44 Wire moved to X = 1.5 cm 15:35:48 Wire moved by DX = -1 cm 15:35:57 X0 = 1 cm, dx = -1 cm, VT = -9.278515E-03 VS 15:35:57 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 1 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 9.312333E-03 +- 3.154067E-06 VS (= Tm^2) 15:35:57 The integrated field strength is BL = 9.312332E-02 +- 3.154067E-05 Tm 15:35:57 Magnet Current Measurement... 15:35:59 Power Supply 1 Current, Ips = 85.5668 A 15:35:59 Magnet Current, Imag = 85.5668 A 15:36:00 Power Supply 1 Current, Ips = 85.5586 A 15:36:00 Magnet Current, Imag = 85.5586 A 15:36:01 Power Supply 1 Current, Ips = 85.58241 A 15:36:01 Magnet Current, Imag = 85.58241 A 15:36:03 Power Supply 1 Current, Ips = 85.566 A 15:36:03 Magnet Current, Imag = 85.566 A 15:36:03 Magnet Current Measurement: Imag = 85.56845 +- 8.666686E-03 A 15:36:03 Integrated Voltage Measurement... 15:36:07 Wire moved to X = 1.5 cm 15:36:12 Wire moved by DX = 1 cm 15:36:20 X0 = 2 cm, dx = 1 cm, VT = 9.332208E-03 VS 15:36:21 Wire moved to X = 2.5 cm 15:36:26 Wire moved by DX = -1 cm 15:36:34 X0 = 2 cm, dx = -1 cm, VT = -9.309489E-03 VS 15:36:35 Wire moved to X = 1.5 cm 15:36:39 Wire moved by DX = 1 cm 15:36:48 X0 = 2 cm, dx = 1 cm, VT = 9.329692E-03 VS 15:36:49 Wire moved to X = 2.5 cm 15:36:53 Wire moved by DX = -1 cm 15:37:02 X0 = 2 cm, dx = -1 cm, VT = -9.301861E-03 VS 15:37:03 Wire moved to X = 1.5 cm 15:37:07 Wire moved by DX = 1 cm 15:37:16 X0 = 2 cm, dx = 1 cm, VT = 9.310293E-03 VS 15:37:17 Wire moved to X = 2.5 cm 15:37:21 Wire moved by DX = -1 cm 15:37:29 X0 = 2 cm, dx = -1 cm, VT = -9.306323E-03 VS 15:37:31 Wire moved to X = 1.5 cm 15:37:35 Wire moved by DX = 1 cm 15:37:43 X0 = 2 cm, dx = 1 cm, VT = 9.332202E-03 VS 15:37:45 Wire moved to X = 2.5 cm 15:37:49 Wire moved by DX = -1 cm 15:37:57 X0 = 2 cm, dx = -1 cm, VT = -9.307732E-03 VS 15:37:57 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 2 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 9.316225E-03 +- 4.956109E-06 VS (= Tm^2) 15:37:58 The integrated field strength is BL = 9.316225E-02 +- 4.956109E-05 Tm 15:37:58 Magnet Current Measurement... 15:37:59 Power Supply 1 Current, Ips = 85.5716 A 15:37:59 Magnet Current, Imag = 85.5716 A 15:38:01 Power Supply 1 Current, Ips = 85.5598 A 15:38:01 Magnet Current, Imag = 85.5598 A 15:38:02 Power Supply 1 Current, Ips = 85.5636 A 15:38:02 Magnet Current, Imag = 85.5636 A 15:38:04 Power Supply 1 Current, Ips = 85.5424 A 15:38:04 Magnet Current, Imag = 85.5424 A 15:38:04 Magnet Current Measurement: Imag = 85.55936 +- 1.067148E-02 A 15:38:04 Integrated Voltage Measurement... 15:38:08 Wire moved to X = 2.5 cm 15:38:13 Wire moved by DX = 1 cm 15:38:21 X0 = 3 cm, dx = 1 cm, VT = 9.332458E-03 VS 15:38:22 Wire moved to X = 3.5 cm 15:38:27 Wire moved by DX = -1 cm 15:38:35 X0 = 3 cm, dx = -1 cm, VT = -9.261692E-03 VS 15:38:36 Wire moved to X = 2.5 cm 15:38:41 Wire moved by DX = 1 cm 15:38:49 X0 = 3 cm, dx = 1 cm, VT = 9.361864E-03 VS 15:38:50 Wire moved to X = 3.5 cm 15:38:55 Wire moved by DX = -1 cm 15:39:03 X0 = 3 cm, dx = -1 cm, VT = -9.255266E-03 VS 15:39:04 Wire moved to X = 2.5 cm 15:39:09 Wire moved by DX = 1 cm 15:39:17 X0 = 3 cm, dx = 1 cm, VT = 9.380445E-03 VS 15:39:18 Wire moved to X = 3.5 cm 15:39:23 Wire moved by DX = -1 cm 15:39:31 X0 = 3 cm, dx = -1 cm, VT = -9.243899E-03 VS 15:39:32 Wire moved to X = 2.5 cm 15:39:37 Wire moved by DX = 1 cm 15:39:45 X0 = 3 cm, dx = 1 cm, VT = .0093805 VS 15:39:46 Wire moved to X = 3.5 cm 15:39:51 Wire moved by DX = -1 cm 15:39:59 X0 = 3 cm, dx = -1 cm, VT = -9.243116E-03 VS 15:39:59 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 3 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 9.307405E-03 +- 6.12717E-06 VS (= Tm^2) 15:39:59 The integrated field strength is BL = 9.307405E-02 +- 6.12717E-05 Tm 15:39:59 Magnet Current Measurement... 15:40:01 Power Supply 1 Current, Ips = 85.556 A 15:40:01 Magnet Current, Imag = 85.556 A 15:40:02 Power Supply 1 Current, Ips = 85.5558 A 15:40:02 Magnet Current, Imag = 85.5558 A 15:40:03 Power Supply 1 Current, Ips = 85.553 A 15:40:04 Magnet Current, Imag = 85.553 A 15:40:05 Power Supply 1 Current, Ips = 85.5694 A 15:40:05 Magnet Current, Imag = 85.5694 A 15:40:05 Magnet Current Measurement: Imag = 85.55855 +- 6.377067E-03 A 15:40:05 Integrated Voltage Measurement... 15:40:10 Wire moved to X = 3.5 cm 15:40:14 Wire moved by DX = 1 cm 15:40:22 X0 = 4 cm, dx = 1 cm, VT = 9.364391E-03 VS 15:40:23 Wire moved to X = 4.5 cm 15:40:28 Wire moved by DX = -1 cm 15:40:36 X0 = 4 cm, dx = -1 cm, VT = -9.257144E-03 VS 15:40:38 Wire moved to X = 3.5 cm 15:40:42 Wire moved by DX = 1 cm 15:40:50 X0 = 4 cm, dx = 1 cm, VT = 9.370389E-03 VS 15:40:51 Wire moved to X = 4.5 cm 15:40:56 Wire moved by DX = -1 cm 15:41:04 X0 = 4 cm, dx = -1 cm, VT = -9.27443E-03 VS 15:41:06 Wire moved to X = 3.5 cm 15:41:10 Wire moved by DX = 1 cm 15:41:18 X0 = 4 cm, dx = 1 cm, VT = 9.377409E-03 VS 15:41:20 Wire moved to X = 4.5 cm 15:41:24 Wire moved by DX = -1 cm 15:41:32 X0 = 4 cm, dx = -1 cm, VT = -9.260429E-03 VS 15:41:34 Wire moved to X = 3.5 cm 15:41:38 Wire moved by DX = 1 cm 15:41:46 X0 = 4 cm, dx = 1 cm, VT = 9.37052E-03 VS 15:41:48 Wire moved to X = 4.5 cm 15:41:52 Wire moved by DX = -1 cm 15:42:00 X0 = 4 cm, dx = -1 cm, VT = -9.268969E-03 VS 15:42:00 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 4 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 9.31796E-03 +- 4.348633E-06 VS (= Tm^2) 15:42:00 The integrated field strength is BL = .0931796 +- 4.348633E-05 Tm 15:42:01 Magnet Current Measurement... 15:42:02 Power Supply 1 Current, Ips = 85.5442 A 15:42:02 Magnet Current, Imag = 85.5442 A 15:42:03 Power Supply 1 Current, Ips = 85.5736 A 15:42:04 Magnet Current, Imag = 85.5736 A 15:42:05 Power Supply 1 Current, Ips = 85.5688 A 15:42:05 Magnet Current, Imag = 85.5688 A 15:42:06 Power Supply 1 Current, Ips = 85.5624 A 15:42:06 Magnet Current, Imag = 85.5624 A 15:42:07 Magnet Current Measurement: Imag = 85.56225 +- 1.115457E-02 A 15:42:07 Integrated Voltage Measurement... 15:42:10 Wire moved to X = 4.5 cm 15:42:14 Wire moved by DX = 1 cm 15:42:23 X0 = 5 cm, dx = 1 cm, VT = 9.345728E-03 VS 15:42:24 Wire moved to X = 5.5 cm 15:42:28 Wire moved by DX = -1 cm 15:42:37 X0 = 5 cm, dx = -1 cm, VT = -9.301976E-03 VS 15:42:38 Wire moved to X = 4.5 cm 15:42:42 Wire moved by DX = 1 cm 15:42:51 X0 = 5 cm, dx = 1 cm, VT = 9.332542E-03 VS 15:42:52 Wire moved to X = 5.5 cm 15:42:56 Wire moved by DX = -1 cm 15:43:05 X0 = 5 cm, dx = -1 cm, VT = -9.280131E-03 VS 15:43:06 Wire moved to X = 4.5 cm 15:43:11 Wire moved by DX = 1 cm 15:43:19 X0 = 5 cm, dx = 1 cm, VT = 9.349791E-03 VS 15:43:20 Wire moved to X = 5.5 cm 15:43:25 Wire moved by DX = -1 cm 15:43:33 X0 = 5 cm, dx = -1 cm, VT = -9.269241E-03 VS 15:43:34 Wire moved to X = 4.5 cm 15:43:38 Wire moved by DX = 1 cm 15:43:47 X0 = 5 cm, dx = 1 cm, VT = 9.365242E-03 VS 15:43:48 Wire moved to X = 5.5 cm 15:43:52 Wire moved by DX = -1 cm 15:44:01 X0 = 5 cm, dx = -1 cm, VT = -9.260413E-03 VS 15:44:01 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 5 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 9.313133E-03 +- 6.600436E-06 VS (= Tm^2) 15:44:01 The integrated field strength is BL = 9.313133E-02 +- 6.600436E-05 Tm 15:44:13 Wire moved to X = 0 cm 15:44:22 Magnet Current Ramping to 100 A... 15:45:33 Magnet Current Measurement... 15:45:34 Power Supply 1 Current, Ips = 100.7134 A 15:45:34 Magnet Current, Imag = 100.7134 A 15:45:36 Power Supply 1 Current, Ips = 100.6908 A 15:45:36 Magnet Current, Imag = 100.6908 A 15:45:37 Power Supply 1 Current, Ips = 100.6988 A 15:45:37 Magnet Current, Imag = 100.6988 A 15:45:38 Power Supply 1 Current, Ips = 100.7178 A 15:45:39 Magnet Current, Imag = 100.7178 A 15:45:39 Magnet Current Measurement: Imag = 100.7052 +- 1.088404E-02 A 15:45:39 Integrated Voltage Measurement... 15:45:54 Wire moved to X = -5.5 cm 15:45:58 Wire moved by DX = 1 cm 15:46:07 X0 = -5 cm, dx = 1 cm, VT = 1.092792E-02 VS 15:46:08 Wire moved to X = -4.5 cm 15:46:12 Wire moved by DX = -1 cm 15:46:21 X0 = -5 cm, dx = -1 cm, VT = -1.090523E-02 VS 15:46:22 Wire moved to X = -5.5 cm 15:46:27 Wire moved by DX = 1 cm 15:46:35 X0 = -5 cm, dx = 1 cm, VT = 1.097843E-02 VS 15:46:36 Wire moved to X = -4.5 cm 15:46:40 Wire moved by DX = -1 cm 15:46:49 X0 = -5 cm, dx = -1 cm, VT = -1.090633E-02 VS 15:46:50 Wire moved to X = -5.5 cm 15:46:54 Wire moved by DX = 1 cm 15:47:03 X0 = -5 cm, dx = 1 cm, VT = 1.094533E-02 VS 15:47:04 Wire moved to X = -4.5 cm 15:47:09 Wire moved by DX = -1 cm 15:47:17 X0 = -5 cm, dx = -1 cm, VT = -1.091879E-02 VS 15:47:18 Wire moved to X = -5.5 cm 15:47:23 Wire moved by DX = 1 cm 15:47:31 X0 = -5 cm, dx = 1 cm, VT = 1.098173E-02 VS 15:47:32 Wire moved to X = -4.5 cm 15:47:37 Wire moved by DX = -1 cm 15:47:45 X0 = -5 cm, dx = -1 cm, VT = -.0108896 VS 15:47:45 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -5 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.093167E-02 +- 9.469217E-06 VS (= Tm^2) 15:47:45 The integrated field strength is BL = .1093167 +- 9.469216E-05 Tm 15:47:45 Magnet Current Measurement... 15:47:47 Power Supply 1 Current, Ips = 100.6912 A 15:47:47 Magnet Current, Imag = 100.6912 A 15:47:48 Power Supply 1 Current, Ips = 100.6938 A 15:47:48 Magnet Current, Imag = 100.6938 A 15:47:50 Power Supply 1 Current, Ips = 100.7222 A 15:47:50 Magnet Current, Imag = 100.7222 A 15:47:51 Power Supply 1 Current, Ips = 100.6854 A 15:47:51 Magnet Current, Imag = 100.6854 A 15:47:51 Magnet Current Measurement: Imag = 100.6982 +- 1.421461E-02 A 15:47:51 Integrated Voltage Measurement... 15:47:56 Wire moved to X = -4.5 cm 15:48:00 Wire moved by DX = 1 cm 15:48:08 X0 = -4 cm, dx = 1 cm, VT = 1.096412E-02 VS 15:48:10 Wire moved to X = -3.5 cm 15:48:14 Wire moved by DX = -1 cm 15:48:22 X0 = -4 cm, dx = -1 cm, VT = -1.089127E-02 VS 15:48:24 Wire moved to X = -4.5 cm 15:48:28 Wire moved by DX = 1 cm 15:48:36 X0 = -4 cm, dx = 1 cm, VT = .010924 VS 15:48:38 Wire moved to X = -3.5 cm 15:48:42 Wire moved by DX = -1 cm 15:48:50 X0 = -4 cm, dx = -1 cm, VT = -1.090086E-02 VS 15:48:52 Wire moved to X = -4.5 cm 15:48:56 Wire moved by DX = 1 cm 15:49:04 X0 = -4 cm, dx = 1 cm, VT = 1.099757E-02 VS 15:49:06 Wire moved to X = -3.5 cm 15:49:10 Wire moved by DX = -1 cm 15:49:18 X0 = -4 cm, dx = -1 cm, VT = -1.095721E-02 VS 15:49:20 Wire moved to X = -4.5 cm 15:49:24 Wire moved by DX = 1 cm 15:49:32 X0 = -4 cm, dx = 1 cm, VT = 1.102043E-02 VS 15:49:34 Wire moved to X = -3.5 cm 15:49:38 Wire moved by DX = -1 cm 15:49:46 X0 = -4 cm, dx = -1 cm, VT = -1.085049E-02 VS 15:49:46 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -4 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.093824E-02 +- 2.40713E-05 VS (= Tm^2) 15:49:46 The integrated field strength is BL = .1093824 +- 2.40713E-04 Tm 15:49:47 Magnet Current Measurement... 15:49:48 Power Supply 1 Current, Ips = 100.6964 A 15:49:48 Magnet Current, Imag = 100.6964 A 15:49:50 Power Supply 1 Current, Ips = 100.7272 A 15:49:50 Magnet Current, Imag = 100.7272 A 15:49:51 Power Supply 1 Current, Ips = 100.7278 A 15:49:51 Magnet Current, Imag = 100.7278 A 15:49:52 Power Supply 1 Current, Ips = 100.7232 A 15:49:52 Magnet Current, Imag = 100.7232 A 15:49:53 Magnet Current Measurement: Imag = 100.7187 +- 1.296904E-02 A 15:49:53 Integrated Voltage Measurement... 15:49:56 Wire moved to X = -3.5 cm 15:50:00 Wire moved by DX = 1 cm 15:50:09 X0 = -3 cm, dx = 1 cm, VT = 1.097383E-02 VS 15:50:10 Wire moved to X = -2.5 cm 15:50:14 Wire moved by DX = -1 cm 15:50:23 X0 = -3 cm, dx = -1 cm, VT = -1.089496E-02 VS 15:50:24 Wire moved to X = -3.5 cm 15:50:28 Wire moved by DX = 1 cm 15:50:37 X0 = -3 cm, dx = 1 cm, VT = 1.099682E-02 VS 15:50:38 Wire moved to X = -2.5 cm 15:50:42 Wire moved by DX = -1 cm 15:50:51 X0 = -3 cm, dx = -1 cm, VT = -1.090435E-02 VS 15:50:52 Wire moved to X = -3.5 cm 15:50:56 Wire moved by DX = 1 cm 15:51:05 X0 = -3 cm, dx = 1 cm, VT = 1.096854E-02 VS 15:51:06 Wire moved to X = -2.5 cm 15:51:10 Wire moved by DX = -1 cm 15:51:19 X0 = -3 cm, dx = -1 cm, VT = -1.086561E-02 VS 15:51:20 Wire moved to X = -3.5 cm 15:51:24 Wire moved by DX = 1 cm 15:51:33 X0 = -3 cm, dx = 1 cm, VT = 1.098361E-02 VS 15:51:34 Wire moved to X = -2.5 cm 15:51:38 Wire moved by DX = -1 cm 15:51:47 X0 = -3 cm, dx = -1 cm, VT = -1.091682E-02 VS 15:51:47 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -3 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.093807E-02 +- 1.376843E-05 VS (= Tm^2) 15:51:47 The integrated field strength is BL = .1093807 +- 1.376843E-04 Tm 15:51:47 Magnet Current Measurement... 15:51:48 Power Supply 1 Current, Ips = 100.7154 A 15:51:49 Magnet Current, Imag = 100.7154 A 15:51:50 Power Supply 1 Current, Ips = 100.6948 A 15:51:50 Magnet Current, Imag = 100.6948 A 15:51:51 Power Supply 1 Current, Ips = 100.73 A 15:51:51 Magnet Current, Imag = 100.73 A 15:51:53 Power Supply 1 Current, Ips = 100.6856 A 15:51:53 Magnet Current, Imag = 100.6856 A 15:51:53 Magnet Current Measurement: Imag = 100.7065 +- 1.735856E-02 A 15:51:53 Integrated Voltage Measurement... 15:51:56 Wire moved to X = -2.5 cm 15:52:01 Wire moved by DX = 1 cm 15:52:09 X0 = -2 cm, dx = 1 cm, VT = 1.099851E-02 VS 15:52:11 Wire moved to X = -1.5 cm 15:52:15 Wire moved by DX = -1 cm 15:52:23 X0 = -2 cm, dx = -1 cm, VT = -1.093167E-02 VS 15:52:25 Wire moved to X = -2.5 cm 15:52:29 Wire moved by DX = 1 cm 15:52:37 X0 = -2 cm, dx = 1 cm, VT = .0110114 VS 15:52:39 Wire moved to X = -1.5 cm 15:52:43 Wire moved by DX = -1 cm 15:52:51 X0 = -2 cm, dx = -1 cm, VT = -1.095907E-02 VS 15:52:53 Wire moved to X = -2.5 cm 15:52:57 Wire moved by DX = 1 cm 15:53:05 X0 = -2 cm, dx = 1 cm, VT = 1.099125E-02 VS 15:53:07 Wire moved to X = -1.5 cm 15:53:11 Wire moved by DX = -1 cm 15:53:19 X0 = -2 cm, dx = -1 cm, VT = -1.086321E-02 VS 15:53:21 Wire moved to X = -2.5 cm 15:53:25 Wire moved by DX = 1 cm 15:53:33 X0 = -2 cm, dx = 1 cm, VT = 1.100794E-02 VS 15:53:35 Wire moved to X = -1.5 cm 15:53:39 Wire moved by DX = -1 cm 15:53:47 X0 = -2 cm, dx = -1 cm, VT = -1.088238E-02 VS 15:53:47 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -2 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.095568E-02 +- 2.169171E-05 VS (= Tm^2) 15:53:47 The integrated field strength is BL = .1095568 +- 2.169171E-04 Tm 15:53:48 Magnet Current Measurement... 15:53:49 Power Supply 1 Current, Ips = 100.6974 A 15:53:49 Magnet Current, Imag = 100.6974 A 15:53:50 Power Supply 1 Current, Ips = 100.723 A 15:53:51 Magnet Current, Imag = 100.723 A 15:53:52 Power Supply 1 Current, Ips = 100.7218 A 15:53:52 Magnet Current, Imag = 100.7218 A 15:53:53 Power Supply 1 Current, Ips = 100.7092 A 15:53:53 Magnet Current, Imag = 100.7092 A 15:53:53 Magnet Current Measurement: Imag = 100.7129 +- 1.043067E-02 A 15:53:54 Integrated Voltage Measurement... 15:53:58 Wire moved to X = -1.5 cm 15:54:02 Wire moved by DX = 1 cm 15:54:10 X0 = -1 cm, dx = 1 cm, VT = .011022 VS 15:54:12 Wire moved to X = -.5 cm 15:54:16 Wire moved by DX = -1 cm 15:54:24 X0 = -1 cm, dx = -1 cm, VT = -1.093072E-02 VS 15:54:26 Wire moved to X = -1.5 cm 15:54:30 Wire moved by DX = 1 cm 15:54:38 X0 = -1 cm, dx = 1 cm, VT = 1.100766E-02 VS 15:54:40 Wire moved to X = -.5 cm 15:54:44 Wire moved by DX = -1 cm 15:54:52 X0 = -1 cm, dx = -1 cm, VT = -1.088635E-02 VS 15:54:54 Wire moved to X = -1.5 cm 15:54:58 Wire moved by DX = 1 cm 15:55:06 X0 = -1 cm, dx = 1 cm, VT = 1.105919E-02 VS 15:55:08 Wire moved to X = -.5 cm 15:55:12 Wire moved by DX = -1 cm 15:55:20 X0 = -1 cm, dx = -1 cm, VT = -1.087238E-02 VS 15:55:22 Wire moved to X = -1.5 cm 15:55:26 Wire moved by DX = 1 cm 15:55:34 X0 = -1 cm, dx = 1 cm, VT = 1.099183E-02 VS 15:55:36 Wire moved to X = -.5 cm 15:55:40 Wire moved by DX = -1 cm 15:55:48 X0 = -1 cm, dx = -1 cm, VT = -1.086476E-02 VS 15:55:48 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -1 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.095436E-02 +- 1.835892E-05 VS (= Tm^2) 15:55:48 The integrated field strength is BL = .1095436 +- 1.835892E-04 Tm 15:55:49 Magnet Current Measurement... 15:55:50 Power Supply 1 Current, Ips = 100.6684 A 15:55:50 Magnet Current, Imag = 100.6684 A 15:55:51 Power Supply 1 Current, Ips = 100.6858 A 15:55:52 Magnet Current, Imag = 100.6858 A 15:55:53 Power Supply 1 Current, Ips = 100.7022 A 15:55:53 Magnet Current, Imag = 100.7022 A 15:55:54 Power Supply 1 Current, Ips = 100.6982 A 15:55:54 Magnet Current, Imag = 100.6982 A 15:55:55 Magnet Current Measurement: Imag = 100.6886 +- 1.316379E-02 A 15:55:55 Integrated Voltage Measurement... 15:55:59 Wire moved to X = -.5 cm 15:56:03 Wire moved by DX = 1 cm 15:56:12 X0 = 0 cm, dx = 1 cm, VT = 1.099772E-02 VS 15:56:13 Wire moved to X = .5 cm 15:56:17 Wire moved by DX = -1 cm 15:56:26 X0 = 0 cm, dx = -1 cm, VT = -1.087227E-02 VS 15:56:27 Wire moved to X = -.5 cm 15:56:31 Wire moved by DX = 1 cm 15:56:40 X0 = 0 cm, dx = 1 cm, VT = 1.097677E-02 VS 15:56:41 Wire moved to X = .5 cm 15:56:45 Wire moved by DX = -1 cm 15:56:54 X0 = 0 cm, dx = -1 cm, VT = -1.086389E-02 VS 15:56:55 Wire moved to X = -.5 cm 15:56:59 Wire moved by DX = 1 cm 15:57:07 X0 = 0 cm, dx = 1 cm, VT = .0110054 VS 15:57:09 Wire moved to X = .5 cm 15:57:13 Wire moved by DX = -1 cm 15:57:21 X0 = 0 cm, dx = -1 cm, VT = -1.084563E-02 VS 15:57:23 Wire moved to X = -.5 cm 15:57:27 Wire moved by DX = 1 cm 15:57:35 X0 = 0 cm, dx = 1 cm, VT = 1.107195E-02 VS 15:57:37 Wire moved to X = .5 cm 15:57:41 Wire moved by DX = -1 cm 15:57:49 X0 = 0 cm, dx = -1 cm, VT = -1.085576E-02 VS 15:57:49 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.093617E-02 +- 1.682366E-05 VS (= Tm^2) 15:57:49 The integrated field strength is BL = .1093617 +- 1.682366E-04 Tm 15:57:50 Magnet Current Measurement... 15:57:51 Power Supply 1 Current, Ips = 100.7256 A 15:57:51 Magnet Current, Imag = 100.7256 A 15:57:52 Power Supply 1 Current, Ips = 100.7166 A 15:57:53 Magnet Current, Imag = 100.7166 A 15:57:54 Power Supply 1 Current, Ips = 100.709 A 15:57:54 Magnet Current, Imag = 100.709 A 15:57:55 Power Supply 1 Current, Ips = 100.7124 A 15:57:55 Magnet Current, Imag = 100.7124 A 15:57:55 Magnet Current Measurement: Imag = 100.7159 +- 6.218159E-03 A 15:57:56 Integrated Voltage Measurement... 15:57:59 Wire moved to X = .5 cm 15:58:03 Wire moved by DX = 1 cm 15:58:11 X0 = 1 cm, dx = 1 cm, VT = 1.106154E-02 VS 15:58:13 Wire moved to X = 1.5 cm 15:58:17 Wire moved by DX = -1 cm 15:58:25 X0 = 1 cm, dx = -1 cm, VT = -1.088512E-02 VS 15:58:27 Wire moved to X = .5 cm 15:58:31 Wire moved by DX = 1 cm 15:58:39 X0 = 1 cm, dx = 1 cm, VT = 1.101926E-02 VS 15:58:41 Wire moved to X = 1.5 cm 15:58:45 Wire moved by DX = -1 cm 15:58:53 X0 = 1 cm, dx = -1 cm, VT = -1.088358E-02 VS 15:58:55 Wire moved to X = .5 cm 15:58:59 Wire moved by DX = 1 cm 15:59:07 X0 = 1 cm, dx = 1 cm, VT = .0110077 VS 15:59:09 Wire moved to X = 1.5 cm 15:59:13 Wire moved by DX = -1 cm 15:59:21 X0 = 1 cm, dx = -1 cm, VT = -1.092544E-02 VS 15:59:23 Wire moved to X = .5 cm 15:59:27 Wire moved by DX = 1 cm 15:59:35 X0 = 1 cm, dx = 1 cm, VT = 1.096772E-02 VS 15:59:37 Wire moved to X = 1.5 cm 15:59:41 Wire moved by DX = -1 cm 15:59:49 X0 = 1 cm, dx = -1 cm, VT = -1.095874E-02 VS 15:59:49 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 1 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.096364E-02 +- 7.936253E-06 VS (= Tm^2) 15:59:49 The integrated field strength is BL = .1096364 +- 7.936252E-05 Tm 15:59:50 Magnet Current Measurement... 15:59:51 Power Supply 1 Current, Ips = 100.687 A 15:59:51 Magnet Current, Imag = 100.687 A 15:59:52 Power Supply 1 Current, Ips = 100.7076 A 15:59:52 Magnet Current, Imag = 100.7076 A 15:59:54 Power Supply 1 Current, Ips = 100.7026 A 15:59:54 Magnet Current, Imag = 100.7026 A 15:59:55 Power Supply 1 Current, Ips = 100.6914 A 15:59:55 Magnet Current, Imag = 100.6914 A 15:59:56 Magnet Current Measurement: Imag = 100.6972 +- 8.28993E-03 A 15:59:56 Integrated Voltage Measurement... 15:59:59 Wire moved to X = 1.5 cm 16:00:03 Wire moved by DX = 1 cm 16:00:12 X0 = 2 cm, dx = 1 cm, VT = .0109978 VS 16:00:13 Wire moved to X = 2.5 cm 16:00:17 Wire moved by DX = -1 cm 16:00:26 X0 = 2 cm, dx = -1 cm, VT = -1.092725E-02 VS 16:00:27 Wire moved to X = 1.5 cm 16:00:31 Wire moved by DX = 1 cm 16:00:40 X0 = 2 cm, dx = 1 cm, VT = 1.100788E-02 VS 16:00:41 Wire moved to X = 2.5 cm 16:00:46 Wire moved by DX = -1 cm 16:00:54 X0 = 2 cm, dx = -1 cm, VT = -1.088487E-02 VS 16:00:55 Wire moved to X = 1.5 cm 16:01:00 Wire moved by DX = 1 cm 16:01:08 X0 = 2 cm, dx = 1 cm, VT = 1.105317E-02 VS 16:01:09 Wire moved to X = 2.5 cm 16:01:14 Wire moved by DX = -1 cm 16:01:22 X0 = 2 cm, dx = -1 cm, VT = -1.087694E-02 VS 16:01:23 Wire moved to X = 1.5 cm 16:01:28 Wire moved by DX = 1 cm 16:01:36 X0 = 2 cm, dx = 1 cm, VT = 1.099335E-02 VS 16:01:37 Wire moved to X = 2.5 cm 16:01:42 Wire moved by DX = -1 cm 16:01:50 X0 = 2 cm, dx = -1 cm, VT = -1.088745E-02 VS 16:01:50 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 2 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.095359E-02 +- 1.045836E-05 VS (= Tm^2) 16:01:50 The integrated field strength is BL = .1095359 +- 1.045836E-04 Tm 16:01:50 Magnet Current Measurement... 16:01:52 Power Supply 1 Current, Ips = 100.7104 A 16:01:52 Magnet Current, Imag = 100.7104 A 16:01:53 Power Supply 1 Current, Ips = 100.74 A 16:01:53 Magnet Current, Imag = 100.74 A 16:01:55 Power Supply 1 Current, Ips = 100.7002 A 16:01:55 Magnet Current, Imag = 100.7002 A 16:01:56 Power Supply 1 Current, Ips = 100.7138 A 16:01:56 Magnet Current, Imag = 100.7138 A 16:01:56 Magnet Current Measurement: Imag = 100.7161 +- 1.467908E-02 A 16:01:56 Integrated Voltage Measurement... 16:02:01 Wire moved to X = 2.5 cm 16:02:05 Wire moved by DX = 1 cm 16:02:13 X0 = 3 cm, dx = 1 cm, VT = 1.101028E-02 VS 16:02:15 Wire moved to X = 3.5 cm 16:02:19 Wire moved by DX = -1 cm 16:02:27 X0 = 3 cm, dx = -1 cm, VT = -1.089915E-02 VS 16:02:29 Wire moved to X = 2.5 cm 16:02:33 Wire moved by DX = 1 cm 16:02:41 X0 = 3 cm, dx = 1 cm, VT = 1.101026E-02 VS 16:02:43 Wire moved to X = 3.5 cm 16:02:47 Wire moved by DX = -1 cm 16:02:55 X0 = 3 cm, dx = -1 cm, VT = -1.090755E-02 VS 16:02:57 Wire moved to X = 2.5 cm 16:03:01 Wire moved by DX = 1 cm 16:03:09 X0 = 3 cm, dx = 1 cm, VT = 1.099459E-02 VS 16:03:11 Wire moved to X = 3.5 cm 16:03:15 Wire moved by DX = -1 cm 16:03:23 X0 = 3 cm, dx = -1 cm, VT = -1.089613E-02 VS 16:03:25 Wire moved to X = 2.5 cm 16:03:29 Wire moved by DX = 1 cm 16:03:37 X0 = 3 cm, dx = 1 cm, VT = 1.100764E-02 VS 16:03:39 Wire moved to X = 3.5 cm 16:03:43 Wire moved by DX = -1 cm 16:03:51 X0 = 3 cm, dx = -1 cm, VT = -1.089959E-02 VS 16:03:51 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 3 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.095315E-02 +- 4.910786E-06 VS (= Tm^2) 16:03:51 The integrated field strength is BL = .1095315 +- 4.910786E-05 Tm 16:03:52 Magnet Current Measurement... 16:03:53 Power Supply 1 Current, Ips = 100.6854 A 16:03:53 Magnet Current, Imag = 100.6854 A 16:03:55 Power Supply 1 Current, Ips = 100.696 A 16:03:55 Magnet Current, Imag = 100.696 A 16:03:56 Power Supply 1 Current, Ips = 100.6962 A 16:03:56 Magnet Current, Imag = 100.6962 A 16:03:57 Power Supply 1 Current, Ips = 100.6712 A 16:03:58 Magnet Current, Imag = 100.6712 A 16:03:58 Magnet Current Measurement: Imag = 100.6872 +- 1.022067E-02 A 16:03:58 Integrated Voltage Measurement... 16:04:02 Wire moved to X = 3.5 cm 16:04:07 Wire moved by DX = 1 cm 16:04:15 X0 = 4 cm, dx = 1 cm, VT = 1.100124E-02 VS 16:04:16 Wire moved to X = 4.5 cm 16:04:20 Wire moved by DX = -1 cm 16:04:29 X0 = 4 cm, dx = -1 cm, VT = -1.091436E-02 VS 16:04:30 Wire moved to X = 3.5 cm 16:04:35 Wire moved by DX = 1 cm 16:04:43 X0 = 4 cm, dx = 1 cm, VT = 1.098826E-02 VS 16:04:44 Wire moved to X = 4.5 cm 16:04:49 Wire moved by DX = -1 cm 16:04:57 X0 = 4 cm, dx = -1 cm, VT = -1.093459E-02 VS 16:04:58 Wire moved to X = 3.5 cm 16:05:03 Wire moved by DX = 1 cm 16:05:11 X0 = 4 cm, dx = 1 cm, VT = 1.099194E-02 VS 16:05:12 Wire moved to X = 4.5 cm 16:05:17 Wire moved by DX = -1 cm 16:05:25 X0 = 4 cm, dx = -1 cm, VT = -1.090722E-02 VS 16:05:26 Wire moved to X = 3.5 cm 16:05:31 Wire moved by DX = 1 cm 16:05:39 X0 = 4 cm, dx = 1 cm, VT = 1.100107E-02 VS 16:05:40 Wire moved to X = 4.5 cm 16:05:45 Wire moved by DX = -1 cm 16:05:53 X0 = 4 cm, dx = -1 cm, VT = -1.090243E-02 VS 16:05:53 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 4 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.095514E-02 +- 4.717115E-06 VS (= Tm^2) 16:05:53 The integrated field strength is BL = .1095514 +- 4.717115E-05 Tm 16:05:53 Magnet Current Measurement... 16:05:55 Power Supply 1 Current, Ips = 100.7052 A 16:05:55 Magnet Current, Imag = 100.7052 A 16:05:56 Power Supply 1 Current, Ips = 100.7024 A 16:05:56 Magnet Current, Imag = 100.7024 A 16:05:58 Power Supply 1 Current, Ips = 100.7398 A 16:05:58 Magnet Current, Imag = 100.7398 A 16:05:59 Power Supply 1 Current, Ips = 100.6928 A 16:05:59 Magnet Current, Imag = 100.6928 A 16:05:59 Magnet Current Measurement: Imag = 100.7101 +- 1.777945E-02 A 16:05:59 Integrated Voltage Measurement... 16:06:04 Wire moved to X = 4.5 cm 16:06:08 Wire moved by DX = 1 cm 16:06:16 X0 = 5 cm, dx = 1 cm, VT = 1.100081E-02 VS 16:06:18 Wire moved to X = 5.5 cm 16:06:22 Wire moved by DX = -1 cm 16:06:30 X0 = 5 cm, dx = -1 cm, VT = -1.091256E-02 VS 16:06:32 Wire moved to X = 4.5 cm 16:06:36 Wire moved by DX = 1 cm 16:06:44 X0 = 5 cm, dx = 1 cm, VT = 1.099862E-02 VS 16:06:46 Wire moved to X = 5.5 cm 16:06:50 Wire moved by DX = -1 cm 16:06:58 X0 = 5 cm, dx = -1 cm, VT = -1.090209E-02 VS 16:07:00 Wire moved to X = 4.5 cm 16:07:04 Wire moved by DX = 1 cm 16:07:12 X0 = 5 cm, dx = 1 cm, VT = .0110019 VS 16:07:14 Wire moved to X = 5.5 cm 16:07:18 Wire moved by DX = -1 cm 16:07:26 X0 = 5 cm, dx = -1 cm, VT = -1.090932E-02 VS 16:07:28 Wire moved to X = 4.5 cm 16:07:32 Wire moved by DX = 1 cm 16:07:41 X0 = 5 cm, dx = 1 cm, VT = 1.099581E-02 VS 16:07:42 Wire moved to X = 5.5 cm 16:07:46 Wire moved by DX = -1 cm 16:07:55 X0 = 5 cm, dx = -1 cm, VT = -1.093258E-02 VS 16:07:55 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 5 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.095671E-02 +- 4.940366E-06 VS (= Tm^2) 16:07:55 The integrated field strength is BL = .1095671 +- 4.940366E-05 Tm 16:08:07 Wire moved to X = 0 cm 16:42:26 Magnet Current Ramping to 150 A... 16:44:23 Magnet Current Measurement... 16:44:25 Power Supply 1 Current, Ips = 151.2464 A 16:44:25 Magnet Current, Imag = 151.2464 A 16:44:26 Power Supply 1 Current, Ips = 151.2502 A 16:44:26 Magnet Current, Imag = 151.2502 A 16:44:28 Power Supply 1 Current, Ips = 151.2344 A 16:44:28 Magnet Current, Imag = 151.2344 A 16:44:29 Power Supply 1 Current, Ips = 151.2418 A 16:44:29 Magnet Current, Imag = 151.2418 A 16:44:29 Magnet Current Measurement: Imag = 151.2432 +- 5.886299E-03 A 16:44:29 Integrated Voltage Measurement... 16:44:45 Wire moved to X = -5.5 cm 16:44:49 Wire moved by DX = 1 cm 16:44:57 X0 = -5 cm, dx = 1 cm, VT = 1.650618E-02 VS 16:44:59 Wire moved to X = -4.5 cm 16:45:03 Wire moved by DX = -1 cm 16:45:11 X0 = -5 cm, dx = -1 cm, VT = -1.631624E-02 VS 16:45:13 Wire moved to X = -5.5 cm 16:45:17 Wire moved by DX = 1 cm 16:45:25 X0 = -5 cm, dx = 1 cm, VT = 1.640194E-02 VS 16:45:27 Wire moved to X = -4.5 cm 16:45:31 Wire moved by DX = -1 cm 16:45:39 X0 = -5 cm, dx = -1 cm, VT = -1.632504E-02 VS 16:45:41 Wire moved to X = -5.5 cm 16:45:45 Wire moved by DX = 1 cm 16:45:53 X0 = -5 cm, dx = 1 cm, VT = 1.637759E-02 VS 16:45:55 Wire moved to X = -4.5 cm 16:45:59 Wire moved by DX = -1 cm 16:46:08 X0 = -5 cm, dx = -1 cm, VT = -1.628655E-02 VS 16:46:09 Wire moved to X = -5.5 cm 16:46:13 Wire moved by DX = 1 cm 16:46:21 X0 = -5 cm, dx = 1 cm, VT = 1.648323E-02 VS 16:46:23 Wire moved to X = -4.5 cm 16:46:27 Wire moved by DX = -1 cm 16:46:36 X0 = -5 cm, dx = -1 cm, VT = -1.628692E-02 VS 16:46:36 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -5 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.637296E-02 +- 2.903433E-05 VS (= Tm^2) 16:46:36 The integrated field strength is BL = .1637296 +- 2.903433E-04 Tm 16:46:36 Magnet Current Measurement... 16:46:37 Power Supply 1 Current, Ips = 151.2368 A 16:46:38 Magnet Current, Imag = 151.2368 A 16:46:39 Power Supply 1 Current, Ips = 151.2208 A 16:46:39 Magnet Current, Imag = 151.2208 A 16:46:40 Power Supply 1 Current, Ips = 151.2306 A 16:46:40 Magnet Current, Imag = 151.2306 A 16:46:42 Power Supply 1 Current, Ips = 151.261 A 16:46:42 Magnet Current, Imag = 151.261 A 16:46:42 Magnet Current Measurement: Imag = 151.2373 +- 1.482606E-02 A 16:46:42 Integrated Voltage Measurement... 16:46:45 Wire moved to X = -4.5 cm 16:46:50 Wire moved by DX = 1 cm 16:46:58 X0 = -4 cm, dx = 1 cm, VT = 1.649473E-02 VS 16:46:59 Wire moved to X = -3.5 cm 16:47:04 Wire moved by DX = -1 cm 16:47:12 X0 = -4 cm, dx = -1 cm, VT = -1.634954E-02 VS 16:47:13 Wire moved to X = -4.5 cm 16:47:18 Wire moved by DX = 1 cm 16:47:26 X0 = -4 cm, dx = 1 cm, VT = 1.647828E-02 VS 16:47:27 Wire moved to X = -3.5 cm 16:47:32 Wire moved by DX = -1 cm 16:47:40 X0 = -4 cm, dx = -1 cm, VT = -1.633771E-02 VS 16:47:41 Wire moved to X = -4.5 cm 16:47:46 Wire moved by DX = 1 cm 16:47:54 X0 = -4 cm, dx = 1 cm, VT = 1.641139E-02 VS 16:47:55 Wire moved to X = -3.5 cm 16:48:00 Wire moved by DX = -1 cm 16:48:08 X0 = -4 cm, dx = -1 cm, VT = -1.635924E-02 VS 16:48:10 Wire moved to X = -4.5 cm 16:48:14 Wire moved by DX = 1 cm 16:48:22 X0 = -4 cm, dx = 1 cm, VT = 1.644659E-02 VS 16:48:24 Wire moved to X = -3.5 cm 16:48:28 Wire moved by DX = -1 cm 16:48:36 X0 = -4 cm, dx = -1 cm, VT = -1.635854E-02 VS 16:48:36 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -4 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = .0164045 +- 1.318032E-05 VS (= Tm^2) 16:48:36 The integrated field strength is BL = .164045 +- 1.318032E-04 Tm 16:48:37 Magnet Current Measurement... 16:48:38 Power Supply 1 Current, Ips = 151.2438 A 16:48:38 Magnet Current, Imag = 151.2438 A 16:48:39 Power Supply 1 Current, Ips = 151.2336 A 16:48:40 Magnet Current, Imag = 151.2336 A 16:48:41 Power Supply 1 Current, Ips = 151.2426 A 16:48:41 Magnet Current, Imag = 151.2426 A 16:48:42 Power Supply 1 Current, Ips = 151.2332 A 16:48:42 Magnet Current, Imag = 151.2332 A 16:48:43 Magnet Current Measurement: Imag = 151.2383 +- 4.918741E-03 A 16:48:43 Integrated Voltage Measurement... 16:48:47 Wire moved to X = -3.5 cm 16:48:51 Wire moved by DX = 1 cm 16:49:00 X0 = -3 cm, dx = 1 cm, VT = .0164708 VS 16:49:01 Wire moved to X = -2.5 cm 16:49:05 Wire moved by DX = -1 cm 16:49:14 X0 = -3 cm, dx = -1 cm, VT = -1.639036E-02 VS 16:49:15 Wire moved to X = -3.5 cm 16:49:20 Wire moved by DX = 1 cm 16:49:28 X0 = -3 cm, dx = 1 cm, VT = 1.644473E-02 VS 16:49:29 Wire moved to X = -2.5 cm 16:49:34 Wire moved by DX = -1 cm 16:49:42 X0 = -3 cm, dx = -1 cm, VT = -1.634096E-02 VS 16:49:43 Wire moved to X = -3.5 cm 16:49:48 Wire moved by DX = 1 cm 16:49:56 X0 = -3 cm, dx = 1 cm, VT = 1.640251E-02 VS 16:49:57 Wire moved to X = -2.5 cm 16:50:02 Wire moved by DX = -1 cm 16:50:10 X0 = -3 cm, dx = -1 cm, VT = -1.641819E-02 VS 16:50:11 Wire moved to X = -3.5 cm 16:50:16 Wire moved by DX = 1 cm 16:50:24 X0 = -3 cm, dx = 1 cm, VT = 1.645355E-02 VS 16:50:25 Wire moved to X = -2.5 cm 16:50:30 Wire moved by DX = -1 cm 16:50:38 X0 = -3 cm, dx = -1 cm, VT = -1.630167E-02 VS 16:50:38 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -3 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.640284E-02 +- 1.976441E-05 VS (= Tm^2) 16:50:38 The integrated field strength is BL = .1640284 +- 1.976441E-04 Tm 16:50:39 Magnet Current Measurement... 16:50:40 Power Supply 1 Current, Ips = 151.2312 A 16:50:40 Magnet Current, Imag = 151.2312 A 16:50:41 Power Supply 1 Current, Ips = 151.2446 A 16:50:41 Magnet Current, Imag = 151.2446 A 16:50:43 Power Supply 1 Current, Ips = 151.2402 A 16:50:43 Magnet Current, Imag = 151.2402 A 16:50:44 Power Supply 1 Current, Ips = 151.2378 A 16:50:44 Magnet Current, Imag = 151.2378 A 16:50:44 Magnet Current Measurement: Imag = 151.2385 +- 4.842586E-03 A 16:50:45 Integrated Voltage Measurement... 16:50:48 Wire moved to X = -2.5 cm 16:50:52 Wire moved by DX = 1 cm 16:51:01 X0 = -2 cm, dx = 1 cm, VT = 1.644938E-02 VS 16:51:02 Wire moved to X = -1.5 cm 16:51:06 Wire moved by DX = -1 cm 16:51:14 X0 = -2 cm, dx = -1 cm, VT = -.016294 VS 16:51:16 Wire moved to X = -2.5 cm 16:51:20 Wire moved by DX = 1 cm 16:51:29 X0 = -2 cm, dx = 1 cm, VT = 1.645764E-02 VS 16:51:30 Wire moved to X = -1.5 cm 16:51:34 Wire moved by DX = -1 cm 16:51:43 X0 = -2 cm, dx = -1 cm, VT = -1.633004E-02 VS 16:51:44 Wire moved to X = -2.5 cm 16:51:48 Wire moved by DX = 1 cm 16:51:57 X0 = -2 cm, dx = 1 cm, VT = 1.645715E-02 VS 16:51:58 Wire moved to X = -1.5 cm 16:52:02 Wire moved by DX = -1 cm 16:52:11 X0 = -2 cm, dx = -1 cm, VT = -1.631044E-02 VS 16:52:12 Wire moved to X = -2.5 cm 16:52:17 Wire moved by DX = 1 cm 16:52:25 X0 = -2 cm, dx = 1 cm, VT = 1.650028E-02 VS 16:52:26 Wire moved to X = -1.5 cm 16:52:30 Wire moved by DX = -1 cm 16:52:39 X0 = -2 cm, dx = -1 cm, VT = -1.629962E-02 VS 16:52:39 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -2 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.638732E-02 +- 1.070821E-05 VS (= Tm^2) 16:52:39 The integrated field strength is BL = .1638732 +- 1.070821E-04 Tm 16:52:39 Magnet Current Measurement... 16:52:41 Power Supply 1 Current, Ips = 151.2384 A 16:52:41 Magnet Current, Imag = 151.2384 A 16:52:42 Power Supply 1 Current, Ips = 151.247 A 16:52:42 Magnet Current, Imag = 151.247 A 16:52:43 Power Supply 1 Current, Ips = 151.2276 A 16:52:43 Magnet Current, Imag = 151.2276 A 16:52:45 Power Supply 1 Current, Ips = 151.218 A 16:52:45 Magnet Current, Imag = 151.218 A 16:52:45 Magnet Current Measurement: Imag = 151.2328 +- .0109447 A 16:52:45 Integrated Voltage Measurement... 16:52:49 Wire moved to X = -1.5 cm 16:52:53 Wire moved by DX = 1 cm 16:53:01 X0 = -1 cm, dx = 1 cm, VT = 1.646218E-02 VS 16:53:02 Wire moved to X = -.5 cm 16:53:07 Wire moved by DX = -1 cm 16:53:15 X0 = -1 cm, dx = -1 cm, VT = -1.630796E-02 VS 16:53:16 Wire moved to X = -1.5 cm 16:53:21 Wire moved by DX = 1 cm 16:53:29 X0 = -1 cm, dx = 1 cm, VT = 1.642836E-02 VS 16:53:30 Wire moved to X = -.5 cm 16:53:35 Wire moved by DX = -1 cm 16:53:43 X0 = -1 cm, dx = -1 cm, VT = -1.637003E-02 VS 16:53:44 Wire moved to X = -1.5 cm 16:53:49 Wire moved by DX = 1 cm 16:53:57 X0 = -1 cm, dx = 1 cm, VT = 1.650584E-02 VS 16:53:58 Wire moved to X = -.5 cm 16:54:03 Wire moved by DX = -1 cm 16:54:11 X0 = -1 cm, dx = -1 cm, VT = -1.637643E-02 VS 16:54:12 Wire moved to X = -1.5 cm 16:54:17 Wire moved by DX = 1 cm 16:54:25 X0 = -1 cm, dx = 1 cm, VT = 1.643365E-02 VS 16:54:26 Wire moved to X = -.5 cm 16:54:31 Wire moved by DX = -1 cm 16:54:39 X0 = -1 cm, dx = -1 cm, VT = -1.633567E-02 VS 16:54:39 Integrated Voltage Measurement: Center Of Wire Motion, X0 = -1 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.640251E-02 +- 2.305229E-05 VS (= Tm^2) 16:54:39 The integrated field strength is BL = .1640251 +- 2.305229E-04 Tm 16:54:39 Magnet Current Measurement... 16:54:41 Power Supply 1 Current, Ips = 151.232 A 16:54:41 Magnet Current, Imag = 151.232 A 16:54:42 Power Supply 1 Current, Ips = 151.2376 A 16:54:42 Magnet Current, Imag = 151.2376 A 16:54:44 Power Supply 1 Current, Ips = 151.191 A 16:54:44 Magnet Current, Imag = 151.191 A 16:54:45 Power Supply 1 Current, Ips = 151.2244 A 16:54:45 Magnet Current, Imag = 151.2244 A 16:54:45 Magnet Current Measurement: Imag = 151.2213 +- 1.808471E-02 A 16:54:45 Integrated Voltage Measurement... 16:54:50 Wire moved to X = -.5 cm 16:54:54 Wire moved by DX = 1 cm 16:55:02 X0 = 0 cm, dx = 1 cm, VT = 1.648312E-02 VS 16:55:04 Wire moved to X = .5 cm 16:55:08 Wire moved by DX = -1 cm 16:55:16 X0 = 0 cm, dx = -1 cm, VT = -1.634254E-02 VS 16:55:18 Wire moved to X = -.5 cm 16:55:22 Wire moved by DX = 1 cm 16:55:30 X0 = 0 cm, dx = 1 cm, VT = 1.648412E-02 VS 16:55:32 Wire moved to X = .5 cm 16:55:36 Wire moved by DX = -1 cm 16:55:44 X0 = 0 cm, dx = -1 cm, VT = -1.633342E-02 VS 16:55:46 Wire moved to X = -.5 cm 16:55:50 Wire moved by DX = 1 cm 16:55:58 X0 = 0 cm, dx = 1 cm, VT = 1.653937E-02 VS 16:56:00 Wire moved to X = .5 cm 16:56:04 Wire moved by DX = -1 cm 16:56:12 X0 = 0 cm, dx = -1 cm, VT = -1.631107E-02 VS 16:56:14 Wire moved to X = -.5 cm 16:56:18 Wire moved by DX = 1 cm 16:56:27 X0 = 0 cm, dx = 1 cm, VT = 1.655679E-02 VS 16:56:28 Wire moved to X = .5 cm 16:56:32 Wire moved by DX = -1 cm 16:56:41 X0 = 0 cm, dx = -1 cm, VT = -1.628665E-02 VS 16:56:41 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 0 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.641713E-02 +- 6.612371E-06 VS (= Tm^2) 16:56:41 The integrated field strength is BL = .1641713 +- 6.612371E-05 Tm 16:56:41 Magnet Current Measurement... 16:56:43 Power Supply 1 Current, Ips = 151.2294 A 16:56:43 Magnet Current, Imag = 151.2294 A 16:56:44 Power Supply 1 Current, Ips = 151.2208 A 16:56:44 Magnet Current, Imag = 151.2208 A 16:56:45 Power Supply 1 Current, Ips = 151.2382 A 16:56:45 Magnet Current, Imag = 151.2382 A 16:56:47 Power Supply 1 Current, Ips = 151.2454 A 16:56:47 Magnet Current, Imag = 151.2454 A 16:56:47 Magnet Current Measurement: Imag = 151.2335 +- 9.246798E-03 A 16:56:47 Integrated Voltage Measurement... 16:56:51 Wire moved to X = .5 cm 16:56:55 Wire moved by DX = 1 cm 16:57:03 X0 = 1 cm, dx = 1 cm, VT = 1.649321E-02 VS 16:57:04 Wire moved to X = 1.5 cm 16:57:09 Wire moved by DX = -1 cm 16:57:17 X0 = 1 cm, dx = -1 cm, VT = -1.635697E-02 VS 16:57:18 Wire moved to X = .5 cm 16:57:23 Wire moved by DX = 1 cm 16:57:31 X0 = 1 cm, dx = 1 cm, VT = 1.644081E-02 VS 16:57:32 Wire moved to X = 1.5 cm 16:57:37 Wire moved by DX = -1 cm 16:57:45 X0 = 1 cm, dx = -1 cm, VT = -1.640087E-02 VS 16:57:47 Wire moved to X = .5 cm 16:57:51 Wire moved by DX = 1 cm 16:57:59 X0 = 1 cm, dx = 1 cm, VT = 1.646303E-02 VS 16:58:01 Wire moved to X = 1.5 cm 16:58:05 Wire moved by DX = -1 cm 16:58:13 X0 = 1 cm, dx = -1 cm, VT = -1.640164E-02 VS 16:58:15 Wire moved to X = .5 cm 16:58:19 Wire moved by DX = 1 cm 16:58:27 X0 = 1 cm, dx = 1 cm, VT = .0164464 VS 16:58:29 Wire moved to X = 1.5 cm 16:58:33 Wire moved by DX = -1 cm 16:58:41 X0 = 1 cm, dx = -1 cm, VT = -1.638292E-02 VS 16:58:42 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 1 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.642323E-02 +- 6.432225E-06 VS (= Tm^2) 16:58:42 The integrated field strength is BL = .1642323 +- 6.432225E-05 Tm 16:58:42 Magnet Current Measurement... 16:58:43 Power Supply 1 Current, Ips = 151.259 A 16:58:43 Magnet Current, Imag = 151.259 A 16:58:45 Power Supply 1 Current, Ips = 151.1948 A 16:58:45 Magnet Current, Imag = 151.1948 A 16:58:46 Power Supply 1 Current, Ips = 151.2304 A 16:58:46 Magnet Current, Imag = 151.2304 A 16:58:48 Power Supply 1 Current, Ips = 151.2464 A 16:58:48 Magnet Current, Imag = 151.2464 A 16:58:48 Magnet Current Measurement: Imag = 151.2327 +- 2.408816E-02 A 16:58:48 Integrated Voltage Measurement... 16:58:52 Wire moved to X = 1.5 cm 16:58:57 Wire moved by DX = 1 cm 16:59:05 X0 = 2 cm, dx = 1 cm, VT = 1.649632E-02 VS 16:59:06 Wire moved to X = 2.5 cm 16:59:11 Wire moved by DX = -1 cm 16:59:19 X0 = 2 cm, dx = -1 cm, VT = -1.633453E-02 VS 16:59:20 Wire moved to X = 1.5 cm 16:59:25 Wire moved by DX = 1 cm 16:59:33 X0 = 2 cm, dx = 1 cm, VT = 1.650329E-02 VS 16:59:34 Wire moved to X = 2.5 cm 16:59:39 Wire moved by DX = -1 cm 16:59:47 X0 = 2 cm, dx = -1 cm, VT = -1.633298E-02 VS 16:59:48 Wire moved to X = 1.5 cm 16:59:53 Wire moved by DX = 1 cm 17:00:01 X0 = 2 cm, dx = 1 cm, VT = .0165057 VS 17:00:02 Wire moved to X = 2.5 cm 17:00:07 Wire moved by DX = -1 cm 17:00:15 X0 = 2 cm, dx = -1 cm, VT = -1.634368E-02 VS 17:00:16 Wire moved to X = 1.5 cm 17:00:21 Wire moved by DX = 1 cm 17:00:29 X0 = 2 cm, dx = 1 cm, VT = .0164954 VS 17:00:31 Wire moved to X = 2.5 cm 17:00:35 Wire moved by DX = -1 cm 17:00:43 X0 = 2 cm, dx = -1 cm, VT = -1.635939E-02 VS 17:00:43 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 2 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.642141E-02 +- 4.824792E-06 VS (= Tm^2) 17:00:43 The integrated field strength is BL = .1642141 +- 4.824792E-05 Tm 17:00:44 Magnet Current Measurement... 17:00:45 Power Supply 1 Current, Ips = 151.2232 A 17:00:45 Magnet Current, Imag = 151.2232 A 17:00:46 Power Supply 1 Current, Ips = 151.2684 A 17:00:47 Magnet Current, Imag = 151.2684 A 17:00:48 Power Supply 1 Current, Ips = 151.2324 A 17:00:48 Magnet Current, Imag = 151.2324 A 17:00:49 Power Supply 1 Current, Ips = 151.2328 A 17:00:49 Magnet Current, Imag = 151.2328 A 17:00:50 Magnet Current Measurement: Imag = 151.2392 +- .0172891 A 17:00:50 Integrated Voltage Measurement... 17:00:54 Wire moved to X = 2.5 cm 17:00:58 Wire moved by DX = 1 cm 17:01:07 X0 = 3 cm, dx = 1 cm, VT = .0164847 VS 17:01:08 Wire moved to X = 3.5 cm 17:01:12 Wire moved by DX = -1 cm 17:01:21 X0 = 3 cm, dx = -1 cm, VT = -1.637283E-02 VS 17:01:22 Wire moved to X = 2.5 cm 17:01:26 Wire moved by DX = 1 cm 17:01:35 X0 = 3 cm, dx = 1 cm, VT = 1.649369E-02 VS 17:01:36 Wire moved to X = 3.5 cm 17:01:40 Wire moved by DX = -1 cm 17:01:49 X0 = 3 cm, dx = -1 cm, VT = -1.637242E-02 VS 17:01:50 Wire moved to X = 2.5 cm 17:01:54 Wire moved by DX = 1 cm 17:02:03 X0 = 3 cm, dx = 1 cm, VT = 1.646199E-02 VS 17:02:04 Wire moved to X = 3.5 cm 17:02:08 Wire moved by DX = -1 cm 17:02:17 X0 = 3 cm, dx = -1 cm, VT = -1.636894E-02 VS 17:02:18 Wire moved to X = 2.5 cm 17:02:22 Wire moved by DX = 1 cm 17:02:31 X0 = 3 cm, dx = 1 cm, VT = 1.648898E-02 VS 17:02:32 Wire moved to X = 3.5 cm 17:02:36 Wire moved by DX = -1 cm 17:02:45 X0 = 3 cm, dx = -1 cm, VT = -1.633212E-02 VS 17:02:45 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 3 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.642196E-02 +- 9.243176E-06 VS (= Tm^2) 17:02:45 The integrated field strength is BL = .1642196 +- 9.243176E-05 Tm 17:02:45 Magnet Current Measurement... 17:02:47 Power Supply 1 Current, Ips = 151.2624 A 17:02:47 Magnet Current, Imag = 151.2624 A 17:02:48 Power Supply 1 Current, Ips = 151.2486 A 17:02:48 Magnet Current, Imag = 151.2486 A 17:02:49 Power Supply 1 Current, Ips = 151.2396 A 17:02:49 Magnet Current, Imag = 151.2396 A 17:02:51 Power Supply 1 Current, Ips = 151.2502 A 17:02:51 Magnet Current, Imag = 151.2502 A 17:02:51 Magnet Current Measurement: Imag = 151.2502 +- 8.119701E-03 A 17:02:51 Integrated Voltage Measurement... 17:02:55 Wire moved to X = 3.5 cm 17:02:59 Wire moved by DX = 1 cm 17:03:07 X0 = 4 cm, dx = 1 cm, VT = 1.651902E-02 VS 17:03:08 Wire moved to X = 4.5 cm 17:03:13 Wire moved by DX = -1 cm 17:03:21 X0 = 4 cm, dx = -1 cm, VT = -1.633102E-02 VS 17:03:22 Wire moved to X = 3.5 cm 17:03:27 Wire moved by DX = 1 cm 17:03:35 X0 = 4 cm, dx = 1 cm, VT = 1.651342E-02 VS 17:03:36 Wire moved to X = 4.5 cm 17:03:41 Wire moved by DX = -1 cm 17:03:49 X0 = 4 cm, dx = -1 cm, VT = -1.631713E-02 VS 17:03:50 Wire moved to X = 3.5 cm 17:03:55 Wire moved by DX = 1 cm 17:04:03 X0 = 4 cm, dx = 1 cm, VT = 1.653066E-02 VS 17:04:04 Wire moved to X = 4.5 cm 17:04:09 Wire moved by DX = -1 cm 17:04:17 X0 = 4 cm, dx = -1 cm, VT = -1.629952E-02 VS 17:04:18 Wire moved to X = 3.5 cm 17:04:23 Wire moved by DX = 1 cm 17:04:31 X0 = 4 cm, dx = 1 cm, VT = 1.651264E-02 VS 17:04:32 Wire moved to X = 4.5 cm 17:04:37 Wire moved by DX = -1 cm 17:04:45 X0 = 4 cm, dx = -1 cm, VT = -1.634045E-02 VS 17:04:45 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 4 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.642048E-02 +- 5.327869E-06 VS (= Tm^2) 17:04:45 The integrated field strength is BL = .1642048 +- 5.327869E-05 Tm 17:04:46 Magnet Current Measurement... 17:04:47 Power Supply 1 Current, Ips = 151.2196 A 17:04:47 Magnet Current, Imag = 151.2196 A 17:04:48 Power Supply 1 Current, Ips = 151.231 A 17:04:48 Magnet Current, Imag = 151.231 A 17:04:50 Power Supply 1 Current, Ips = 151.2622 A 17:04:50 Magnet Current, Imag = 151.2622 A 17:04:51 Power Supply 1 Current, Ips = 151.2166 A 17:04:51 Magnet Current, Imag = 151.2166 A 17:04:51 Magnet Current Measurement: Imag = 151.2324 +- 1.805419E-02 A 17:04:51 Integrated Voltage Measurement... 17:04:56 Wire moved to X = 4.5 cm 17:05:00 Wire moved by DX = 1 cm 17:05:08 X0 = 5 cm, dx = 1 cm, VT = 1.647789E-02 VS 17:05:10 Wire moved to X = 5.5 cm 17:05:14 Wire moved by DX = -1 cm 17:05:22 X0 = 5 cm, dx = -1 cm, VT = -1.634631E-02 VS 17:05:24 Wire moved to X = 4.5 cm 17:05:28 Wire moved by DX = 1 cm 17:05:36 X0 = 5 cm, dx = 1 cm, VT = .0165075 VS 17:05:38 Wire moved to X = 5.5 cm 17:05:42 Wire moved by DX = -1 cm 17:05:50 X0 = 5 cm, dx = -1 cm, VT = -1.631977E-02 VS 17:05:52 Wire moved to X = 4.5 cm 17:05:56 Wire moved by DX = 1 cm 17:06:04 X0 = 5 cm, dx = 1 cm, VT = 1.651574E-02 VS 17:06:06 Wire moved to X = 5.5 cm 17:06:10 Wire moved by DX = -1 cm 17:06:18 X0 = 5 cm, dx = -1 cm, VT = -1.632174E-02 VS 17:06:20 Wire moved to X = 4.5 cm 17:06:24 Wire moved by DX = 1 cm 17:06:32 X0 = 5 cm, dx = 1 cm, VT = 1.651184E-02 VS 17:06:34 Wire moved to X = 5.5 cm 17:06:38 Wire moved by DX = -1 cm 17:06:46 X0 = 5 cm, dx = -1 cm, VT = -1.633754E-02 VS 17:06:46 Integrated Voltage Measurement: Center Of Wire Motion, X0 = 5 cm Distance Wire Moved, Delta X = 1 cm # Measurements For Average, Nmeas = 4 Integrated Voltage, VT = 1.641729E-02 +- 4.927442E-06 VS (= Tm^2) 17:06:47 The integrated field strength is BL = .1641729 +- 4.927442E-05 Tm 17:06:59 Wire moved to X = 0 cm 17:09:25 Magnet Current Ramping to 0 A...