SLAC Magnetic Measurements Date: 09-28-1994 Time: 10:33:23 Magnet Name: 108 Test Operator: bmd Test Stand: D2 Apparatus: Coil 2 Run Number: 1 Comment: Magnet Standardization Currents (Amps): 100.0 950.0 100.0 950.0 100.0 950.0 100.0 Measurement Currents (Amps): 650.0 FIELD UNIFORMITY MEASUREMENTS BL Measurements For The Reference Magnet: I X VT sigVT BL sigBL (A) # (VS) (VS) (TM) (TM) ------- --- -------- -------- -------- -------- 650.17 1 0.95687 0.00003 0.99330 0.00003 650.17 2 0.95688 0.00005 0.99331 0.00005 650.16 3 0.95691 0.00005 0.99334 0.00005 BL Measurements For The Magnet Under Test: I X VTXC sigVTXC BL sigBL ratio sig (A) # (VS) (VS) (TM) (TM) VTXC/VTR VTXC/VTR ------- --- -------- -------- -------- -------- -------- -------- 650.16 1 0.95563 0.00010 0.99201 0.00010 0.99871 0.00010 650.16 2 0.95560 0.00007 0.99198 0.00007 0.99867 0.00008 650.16 3 0.95561 0.00005 0.99200 0.00005 0.99864 0.00007