SLAC Magnetic Measurements Date: 09-27-1994 Time: 07:36:46 Magnet Name: 042 Test Operator: bmd Test Stand: D1 Apparatus: Coil 1 Run Number: 2 Comment: Magnet Standardization Currents (Amps): 100.0 950.0 100.0 950.0 100.0 950.0 100.0 Measurement Currents (Amps): 650.0 FIELD UNIFORMITY MEASUREMENTS BL Measurements For The Reference Magnet: I X VT sigVT BL sigBL (A) # (VS) (VS) (TM) (TM) ------- --- -------- -------- -------- -------- 650.16 1 0.95684 0.00005 0.99327 0.00005 650.16 2 0.95687 0.00003 0.99331 0.00003 650.16 3 0.95686 0.00002 0.99330 0.00002 BL Measurements For The Magnet Under Test: I X VTXC sigVTXC BL sigBL ratio sig (A) # (VS) (VS) (TM) (TM) VTXC/VTR VTXC/VTR ------- --- -------- -------- -------- -------- -------- -------- 650.16 1 0.95514 0.00010 0.99151 0.00011 0.99822 0.00012 650.16 2 0.95510 0.00007 0.99146 0.00007 0.99814 0.00008 650.16 3 0.95513 0.00006 0.99150 0.00006 0.99819 0.00006