SLAC Magnetic Measurements Date: 01-23-2004 Time: 15:38:23 Project: Orion Magnet Type: solenoid Magnet Name: Ecomp Serial Number: Run Number: 6 Measurement Device: B9900 Hall probe Operator: sa Comment: 150 A left hand coils power only. Standardization: 4 cycles from 0.0 A to 220.0 A to 0.0 A Test Currents (A): 150.0 15:38:35 Stage Zeroed 15:38:35 MoveZ Devices: Move Device = SXDRIVE, Read Device = SXDRIVE 15:39:31 Move Stage, position = -0.250000 15:40:23 Hall Probe Zeroed 15:40:55 Hall Probe Type Being Used, type = B9900 15:41:51 Move Stage, position = 0.000000 15:41:53 Initial Zero Current Measurement, Imag_zero = 0.0000 A 15:41:56 Hall Probe Range Set, range = 5 15:41:56 Magnet current ramping to 220.0000 A... 15:44:33 Magnet current ramping to 0.0000 A... 15:47:08 Magnet current ramping to 220.0000 A... 15:49:45 Magnet current ramping to 0.0000 A... 15:52:20 Magnet current ramping to 220.0000 A... 15:54:57 Magnet current ramping to 0.0000 A... 15:57:33 Magnet current ramping to 220.0000 A... 16:00:09 Magnet current ramping to 0.0000 A... 16:02:45 Magnet current ramping to 150.0000 A... 16:05:37 Move Stage, position = -0.250000 16:05:38 Stage Position Measurement, pos = -0.250000 m 16:05:40 Magnet Current, Imag = 149.9911 A Vtrans = 1.499911 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:40 Hall Probe Field Measurement, B = -0.000100 T 16:05:47 Move Stage, position = -0.240000 16:05:49 Stage Position Measurement, pos = -0.240000 m 16:05:50 Magnet Current, Imag = 149.9931 A Vtrans = 1.499931 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:51 Hall Probe Field Measurement, B = -0.000200 T 16:05:58 Move Stage, position = -0.230000 16:05:59 Stage Position Measurement, pos = -0.230000 m 16:06:01 Magnet Current, Imag = 149.9884 A Vtrans = 1.499884 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:06:01 Hall Probe Field Measurement, B = -0.000200 T 16:06:08 Move Stage, position = -0.220000 16:06:10 Stage Position Measurement, pos = -0.220000 m 16:06:11 Magnet Current, Imag = 149.9917 A Vtrans = 1.499917 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:06:11 Hall Probe Field Measurement, B = -0.000300 T 16:06:19 Move Stage, position = -0.210000 16:06:20 Stage Position Measurement, pos = -0.210000 m 16:06:21 Magnet Current, Imag = 149.9851 A Vtrans = 1.499851 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:06:22 Hall Probe Field Measurement, B = -0.000500 T 16:06:29 Move Stage, position = -0.200000 16:06:31 Stage Position Measurement, pos = -0.200000 m 16:06:32 Magnet Current, Imag = 149.9799 A Vtrans = 1.499799 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:06:32 Hall Probe Field Measurement, B = -0.000600 T 16:06:39 Move Stage, position = -0.190000 16:06:41 Stage Position Measurement, pos = -0.190000 m 16:06:42 Magnet Current, Imag = 149.9934 A Vtrans = 1.499934 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:06:43 Hall Probe Field Measurement, B = -0.000900 T 16:06:50 Move Stage, position = -0.180000 16:06:51 Stage Position Measurement, pos = -0.180000 m 16:06:53 Magnet Current, Imag = 149.9903 A Vtrans = 1.499903 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:06:53 Hall Probe Field Measurement, B = -0.001200 T 16:07:00 Move Stage, position = -0.170000 16:07:02 Stage Position Measurement, pos = -0.170000 m 16:07:03 Magnet Current, Imag = 149.9903 A Vtrans = 1.499903 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:03 Hall Probe Field Measurement, B = -0.001700 T 16:07:11 Move Stage, position = -0.160000 16:07:12 Stage Position Measurement, pos = -0.160000 m 16:07:13 Magnet Current, Imag = 149.9900 A Vtrans = 1.499900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:14 Hall Probe Field Measurement, B = -0.002700 T 16:07:21 Move Stage, position = -0.150000 16:07:23 Stage Position Measurement, pos = -0.150000 m 16:07:24 Magnet Current, Imag = 149.9873 A Vtrans = 1.499873 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:24 Hall Probe Field Measurement, B = -0.004400 T 16:07:31 Move Stage, position = -0.140000 16:07:33 Stage Position Measurement, pos = -0.140000 m 16:07:34 Magnet Current, Imag = 149.9890 A Vtrans = 1.499890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:35 Hall Probe Field Measurement, B = -0.007500 T 16:07:42 Move Stage, position = -0.130000 16:07:43 Stage Position Measurement, pos = -0.130000 m 16:07:45 Magnet Current, Imag = 149.9871 A Vtrans = 1.499871 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:45 Hall Probe Field Measurement, B = -0.013100 T 16:07:52 Move Stage, position = -0.120000 16:07:54 Stage Position Measurement, pos = -0.120000 m 16:07:55 Magnet Current, Imag = 149.9881 A Vtrans = 1.499881 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:55 Hall Probe Field Measurement, B = -0.022100 T 16:08:03 Move Stage, position = -0.110000 16:08:04 Stage Position Measurement, pos = -0.110000 m 16:08:05 Magnet Current, Imag = 149.9943 A Vtrans = 1.499943 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:08:06 Hall Probe Field Measurement, B = -0.035500 T 16:08:13 Move Stage, position = -0.100000 16:08:15 Stage Position Measurement, pos = -0.100000 m 16:08:16 Magnet Current, Imag = 149.9862 A Vtrans = 1.499862 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:08:16 Hall Probe Field Measurement, B = -0.051900 T 16:08:23 Move Stage, position = -0.090000 16:08:25 Stage Position Measurement, pos = -0.090000 m 16:08:26 Magnet Current, Imag = 149.9835 A Vtrans = 1.499835 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:08:27 Hall Probe Field Measurement, B = -0.068700 T 16:08:34 Move Stage, position = -0.080000 16:08:35 Stage Position Measurement, pos = -0.080000 m 16:08:37 Magnet Current, Imag = 149.9878 A Vtrans = 1.499878 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:08:37 Hall Probe Field Measurement, B = -0.083500 T 16:08:44 Move Stage, position = -0.070000 16:08:46 Stage Position Measurement, pos = -0.070000 m 16:08:47 Magnet Current, Imag = 149.9841 A Vtrans = 1.499841 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:08:48 Hall Probe Field Measurement, B = -0.094600 T 16:08:55 Move Stage, position = -0.060000 16:08:56 Stage Position Measurement, pos = -0.060000 m 16:08:57 Magnet Current, Imag = 149.9882 A Vtrans = 1.499882 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:08:58 Hall Probe Field Measurement, B = -0.100900 T 16:09:05 Move Stage, position = -0.050000 16:09:07 Stage Position Measurement, pos = -0.050000 m 16:09:08 Magnet Current, Imag = 149.9910 A Vtrans = 1.499910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:08 Hall Probe Field Measurement, B = -0.104100 T 16:09:15 Move Stage, position = -0.040000 16:09:17 Stage Position Measurement, pos = -0.040000 m 16:09:18 Magnet Current, Imag = 149.9868 A Vtrans = 1.499868 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:19 Hall Probe Field Measurement, B = -0.107400 T 16:09:26 Move Stage, position = -0.030000 16:09:28 Stage Position Measurement, pos = -0.030000 m 16:09:29 Magnet Current, Imag = 149.9854 A Vtrans = 1.499854 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:29 Hall Probe Field Measurement, B = -0.111700 T 16:09:36 Move Stage, position = -0.020000 16:09:38 Stage Position Measurement, pos = -0.020000 m 16:09:39 Magnet Current, Imag = 149.9905 A Vtrans = 1.499905 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:40 Hall Probe Field Measurement, B = -0.115600 T 16:09:47 Move Stage, position = -0.010000 16:09:48 Stage Position Measurement, pos = -0.010000 m 16:09:50 Magnet Current, Imag = 149.9852 A Vtrans = 1.499852 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:50 Hall Probe Field Measurement, B = -0.117400 T 16:09:57 Move Stage, position = 0.000000 16:09:59 Stage Position Measurement, pos = 0.000000 m 16:10:00 Magnet Current, Imag = 149.9851 A Vtrans = 1.499851 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:10:01 Hall Probe Field Measurement, B = -0.117600 T 16:10:08 Move Stage, position = 0.010000 16:10:09 Stage Position Measurement, pos = 0.010000 m 16:10:10 Magnet Current, Imag = 149.9894 A Vtrans = 1.499894 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:10:11 Hall Probe Field Measurement, B = -0.116500 T 16:10:18 Move Stage, position = 0.020000 16:10:20 Stage Position Measurement, pos = 0.020000 m 16:10:21 Magnet Current, Imag = 149.9873 A Vtrans = 1.499873 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:10:21 Hall Probe Field Measurement, B = -0.114300 T 16:10:28 Move Stage, position = 0.030000 16:10:30 Stage Position Measurement, pos = 0.030000 m 16:10:31 Magnet Current, Imag = 149.9859 A Vtrans = 1.499859 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:10:33 Hall Probe Field Measurement, B = -0.111100 T 16:10:40 Move Stage, position = 0.040000 16:10:42 Stage Position Measurement, pos = 0.040000 m 16:10:43 Magnet Current, Imag = 149.9868 A Vtrans = 1.499868 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:10:43 Hall Probe Field Measurement, B = -0.107300 T 16:10:50 Move Stage, position = 0.050000 16:10:52 Stage Position Measurement, pos = 0.050000 m 16:10:53 Magnet Current, Imag = 149.9845 A Vtrans = 1.499845 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:10:54 Hall Probe Field Measurement, B = -0.103600 T 16:11:01 Move Stage, position = 0.060000 16:11:02 Stage Position Measurement, pos = 0.060000 m 16:11:04 Magnet Current, Imag = 149.9905 A Vtrans = 1.499905 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:04 Hall Probe Field Measurement, B = -0.100200 T 16:11:11 Move Stage, position = 0.070000 16:11:13 Stage Position Measurement, pos = 0.070000 m 16:11:14 Magnet Current, Imag = 149.9905 A Vtrans = 1.499905 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:15 Hall Probe Field Measurement, B = -0.094100 T 16:11:22 Move Stage, position = 0.080000 16:11:23 Stage Position Measurement, pos = 0.080000 m 16:11:24 Magnet Current, Imag = 149.9876 A Vtrans = 1.499876 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:25 Hall Probe Field Measurement, B = -0.082000 T 16:11:32 Move Stage, position = 0.090000 16:11:34 Stage Position Measurement, pos = 0.090000 m 16:11:35 Magnet Current, Imag = 149.9853 A Vtrans = 1.499853 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:35 Hall Probe Field Measurement, B = -0.063200 T 16:11:42 Move Stage, position = 0.100000 16:11:44 Stage Position Measurement, pos = 0.100000 m 16:11:45 Magnet Current, Imag = 149.9898 A Vtrans = 1.499898 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:46 Hall Probe Field Measurement, B = -0.043100 T 16:11:53 Move Stage, position = 0.110000 16:11:55 Stage Position Measurement, pos = 0.110000 m 16:11:56 Magnet Current, Imag = 149.9914 A Vtrans = 1.499914 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:56 Hall Probe Field Measurement, B = -0.026500 T 16:12:03 Move Stage, position = 0.120000 16:12:05 Stage Position Measurement, pos = 0.120000 m 16:12:06 Magnet Current, Imag = 149.9861 A Vtrans = 1.499861 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:12:07 Hall Probe Field Measurement, B = -0.015600 T 16:12:14 Move Stage, position = 0.130000 16:12:15 Stage Position Measurement, pos = 0.130000 m 16:12:17 Magnet Current, Imag = 149.9870 A Vtrans = 1.499870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:12:17 Hall Probe Field Measurement, B = -0.009000 T 16:12:24 Move Stage, position = 0.140000 16:12:26 Stage Position Measurement, pos = 0.140000 m 16:12:27 Magnet Current, Imag = 149.9868 A Vtrans = 1.499868 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:12:28 Hall Probe Field Measurement, B = -0.005400 T 16:12:35 Move Stage, position = 0.150000 16:12:36 Stage Position Measurement, pos = 0.150000 m 16:12:37 Magnet Current, Imag = 149.9876 A Vtrans = 1.499876 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:12:38 Hall Probe Field Measurement, B = -0.003400 T 16:12:45 Move Stage, position = 0.160000 16:12:47 Stage Position Measurement, pos = 0.160000 m 16:12:48 Magnet Current, Imag = 149.9889 A Vtrans = 1.499889 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:12:50 Hall Probe Field Measurement, B = -0.002200 T 16:12:57 Move Stage, position = 0.170000 16:12:58 Stage Position Measurement, pos = 0.170000 m 16:13:00 Magnet Current, Imag = 149.9843 A Vtrans = 1.499843 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:00 Hall Probe Field Measurement, B = -0.001500 T 16:13:07 Move Stage, position = 0.180000 16:13:09 Stage Position Measurement, pos = 0.180000 m 16:13:10 Magnet Current, Imag = 149.9843 A Vtrans = 1.499843 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:10 Hall Probe Field Measurement, B = -0.001100 T 16:13:18 Move Stage, position = 0.190000 16:13:19 Stage Position Measurement, pos = 0.190000 m 16:13:20 Magnet Current, Imag = 149.9866 A Vtrans = 1.499866 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:21 Hall Probe Field Measurement, B = -0.000900 T 16:13:28 Move Stage, position = 0.200000 16:13:30 Stage Position Measurement, pos = 0.200000 m 16:13:31 Magnet Current, Imag = 149.9864 A Vtrans = 1.499864 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:31 Hall Probe Field Measurement, B = -0.000600 T 16:13:38 Move Stage, position = 0.210000 16:13:40 Stage Position Measurement, pos = 0.210000 m 16:13:41 Magnet Current, Imag = 149.9873 A Vtrans = 1.499873 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:42 Hall Probe Field Measurement, B = -0.000500 T 16:13:49 Move Stage, position = 0.220000 16:13:51 Stage Position Measurement, pos = 0.220000 m 16:13:52 Magnet Current, Imag = 149.9851 A Vtrans = 1.499851 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:52 Hall Probe Field Measurement, B = -0.000400 T 16:13:59 Move Stage, position = 0.230000 16:14:01 Stage Position Measurement, pos = 0.230000 m 16:14:02 Magnet Current, Imag = 149.9886 A Vtrans = 1.499886 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:14:03 Hall Probe Field Measurement, B = -0.000200 T 16:14:10 Move Stage, position = 0.240000 16:14:11 Stage Position Measurement, pos = 0.240000 m 16:14:13 Magnet Current, Imag = 149.9860 A Vtrans = 1.499860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:14:13 Hall Probe Field Measurement, B = -0.000200 T 16:14:20 Move Stage, position = 0.250000 16:14:22 Stage Position Measurement, pos = 0.250000 m 16:14:23 Magnet Current, Imag = 149.9888 A Vtrans = 1.499888 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:14:24 Hall Probe Field Measurement, B = -0.000200 T 16:15:19 Move Stage, position = 0.000000 16:15:19 Magnet current ramping to 0.0000 A...