SLAC Magnetic Measurements Date: 02-19-2004 Time: 16:03:54 Project: Orion Magnet Type: solenoid Magnet Name: Ecomp Serial Number: Run Number: 24 Measurement Device: B9900 Hall probe Operator: sa Comment: Axial, scan on geo ctr, z=0 is mag ctr, Left Coil #1 (Coil 1 is 1st coil on -z side). powered only. Standardization: 4 cycles from 0.0 A to 220.0 A to 0.0 A Test Currents (A): 150.0 16:04:08 Stage Zeroed 16:04:08 MoveZ Devices: Move Device = SXDRIVE, Read Device = SXDRIVE 16:05:05 Move Stage, position = -0.250000 16:05:48 Hall Probe Zeroed 16:06:19 Hall Probe Type Being Used, type = B9900 16:07:15 Move Stage, position = 0.000000 16:07:16 Initial Zero Current Measurement, Imag_zero = 0.0000 A 16:07:20 Hall Probe Range Set, range = 4 16:07:20 Magnet current ramping to 220.0000 A... 16:09:56 Magnet current ramping to 0.0000 A... 16:12:32 Magnet current ramping to 220.0000 A... 16:15:09 Magnet current ramping to 0.0000 A... 16:17:45 Magnet current ramping to 220.0000 A... 16:20:21 Magnet current ramping to 0.0000 A... 16:22:57 Magnet current ramping to 220.0000 A... 16:25:33 Magnet current ramping to 0.0000 A... 16:28:09 Magnet current ramping to 150.0000 A... 16:31:01 Move Stage, position = -0.250000 16:31:02 Stage Position Measurement, pos = -0.250000 m 16:31:04 Magnet Current, Imag = 150.0337 A Vtrans = 1.500337 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:31:04 Hall Probe Field Measurement, B = -0.000130 T 16:31:11 Move Stage, position = -0.240000 16:31:13 Stage Position Measurement, pos = -0.240000 m 16:31:14 Magnet Current, Imag = 150.0427 A Vtrans = 1.500427 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:31:15 Hall Probe Field Measurement, B = -0.000140 T 16:31:22 Move Stage, position = -0.230000 16:31:23 Stage Position Measurement, pos = -0.230000 m 16:31:25 Magnet Current, Imag = 150.0344 A Vtrans = 1.500344 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:31:25 Hall Probe Field Measurement, B = -0.000170 T 16:31:32 Move Stage, position = -0.220000 16:31:34 Stage Position Measurement, pos = -0.220000 m 16:31:35 Magnet Current, Imag = 150.0351 A Vtrans = 1.500351 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:31:36 Hall Probe Field Measurement, B = -0.000200 T 16:31:43 Move Stage, position = -0.210000 16:31:44 Stage Position Measurement, pos = -0.210000 m 16:31:46 Magnet Current, Imag = 150.0284 A Vtrans = 1.500284 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:31:46 Hall Probe Field Measurement, B = -0.000240 T 16:31:53 Move Stage, position = -0.200000 16:31:55 Stage Position Measurement, pos = -0.200000 m 16:31:56 Magnet Current, Imag = 150.0360 A Vtrans = 1.500360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:31:56 Hall Probe Field Measurement, B = -0.000300 T 16:32:04 Move Stage, position = -0.190000 16:32:05 Stage Position Measurement, pos = -0.190000 m 16:32:06 Magnet Current, Imag = 150.0310 A Vtrans = 1.500310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:32:07 Hall Probe Field Measurement, B = -0.000390 T 16:32:14 Move Stage, position = -0.180000 16:32:16 Stage Position Measurement, pos = -0.180000 m 16:32:17 Magnet Current, Imag = 150.0308 A Vtrans = 1.500308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:32:17 Hall Probe Field Measurement, B = -0.000510 T 16:32:24 Move Stage, position = -0.170000 16:32:26 Stage Position Measurement, pos = -0.170000 m 16:32:27 Magnet Current, Imag = 150.0292 A Vtrans = 1.500292 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:32:28 Hall Probe Field Measurement, B = -0.000720 T 16:32:35 Move Stage, position = -0.160000 16:32:36 Stage Position Measurement, pos = -0.160000 m 16:32:38 Magnet Current, Imag = 150.0206 A Vtrans = 1.500206 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:32:38 Hall Probe Field Measurement, B = -0.001080 T 16:32:45 Move Stage, position = -0.150000 16:32:47 Stage Position Measurement, pos = -0.150000 m 16:32:48 Magnet Current, Imag = 150.0386 A Vtrans = 1.500386 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:32:49 Hall Probe Field Measurement, B = -0.001700 T 16:32:56 Move Stage, position = -0.140000 16:32:57 Stage Position Measurement, pos = -0.140000 m 16:32:58 Magnet Current, Imag = 150.0352 A Vtrans = 1.500352 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:32:59 Hall Probe Field Measurement, B = -0.002820 T 16:33:06 Move Stage, position = -0.130000 16:33:08 Stage Position Measurement, pos = -0.130000 m 16:33:09 Magnet Current, Imag = 150.0268 A Vtrans = 1.500268 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:09 Hall Probe Field Measurement, B = -0.004860 T 16:33:16 Move Stage, position = -0.120000 16:33:18 Stage Position Measurement, pos = -0.120000 m 16:33:19 Magnet Current, Imag = 150.0241 A Vtrans = 1.500241 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:20 Hall Probe Field Measurement, B = -0.008440 T 16:33:27 Move Stage, position = -0.110000 16:33:29 Stage Position Measurement, pos = -0.110000 m 16:33:30 Magnet Current, Imag = 150.0341 A Vtrans = 1.500341 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:30 Hall Probe Field Measurement, B = -0.014260 T 16:33:37 Move Stage, position = -0.100000 16:33:39 Stage Position Measurement, pos = -0.100000 m 16:33:40 Magnet Current, Imag = 150.0312 A Vtrans = 1.500312 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:41 Hall Probe Field Measurement, B = -0.022300 T 16:33:48 Move Stage, position = -0.090000 16:33:49 Stage Position Measurement, pos = -0.090000 m 16:33:51 Magnet Current, Imag = 150.0253 A Vtrans = 1.500253 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:51 Hall Probe Field Measurement, B = -0.031840 T 16:33:58 Move Stage, position = -0.080000 16:34:00 Stage Position Measurement, pos = -0.080000 m 16:34:01 Magnet Current, Imag = 150.0374 A Vtrans = 1.500374 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:34:02 Hall Probe Field Measurement, B = -0.041140 T 16:34:09 Move Stage, position = -0.070000 16:34:10 Stage Position Measurement, pos = -0.070000 m 16:34:11 Magnet Current, Imag = 150.0366 A Vtrans = 1.500366 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:34:12 Hall Probe Field Measurement, B = -0.048310 T 16:34:19 Move Stage, position = -0.060000 16:34:21 Stage Position Measurement, pos = -0.060000 m 16:34:22 Magnet Current, Imag = 150.0242 A Vtrans = 1.500242 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:34:22 Hall Probe Field Measurement, B = -0.050980 T 16:34:30 Move Stage, position = -0.050000 16:34:31 Stage Position Measurement, pos = -0.050000 m 16:34:32 Magnet Current, Imag = 150.0361 A Vtrans = 1.500361 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:34:33 Hall Probe Field Measurement, B = -0.048240 T 16:34:40 Move Stage, position = -0.040000 16:34:42 Stage Position Measurement, pos = -0.040000 m 16:34:43 Magnet Current, Imag = 150.0404 A Vtrans = 1.500404 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:34:43 Hall Probe Field Measurement, B = -0.042000 T 16:34:50 Move Stage, position = -0.030000 16:34:52 Stage Position Measurement, pos = -0.030000 m 16:34:53 Magnet Current, Imag = 150.0345 A Vtrans = 1.500345 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:34:54 Hall Probe Field Measurement, B = -0.035040 T 16:35:01 Move Stage, position = -0.020000 16:35:03 Stage Position Measurement, pos = -0.020000 m 16:35:04 Magnet Current, Imag = 150.0370 A Vtrans = 1.500370 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:04 Hall Probe Field Measurement, B = -0.028920 T 16:35:11 Move Stage, position = -0.010000 16:35:13 Stage Position Measurement, pos = -0.010000 m 16:35:14 Magnet Current, Imag = 150.0240 A Vtrans = 1.500240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:15 Hall Probe Field Measurement, B = -0.024110 T 16:35:22 Move Stage, position = 0.000000 16:35:23 Stage Position Measurement, pos = 0.000000 m 16:35:25 Magnet Current, Imag = 150.0313 A Vtrans = 1.500313 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:25 Hall Probe Field Measurement, B = -0.020460 T 16:35:32 Move Stage, position = 0.010000 16:35:34 Stage Position Measurement, pos = 0.010000 m 16:35:35 Magnet Current, Imag = 150.0314 A Vtrans = 1.500314 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:36 Hall Probe Field Measurement, B = -0.017800 T 16:35:43 Move Stage, position = 0.020000 16:35:44 Stage Position Measurement, pos = 0.020000 m 16:35:46 Magnet Current, Imag = 150.0294 A Vtrans = 1.500294 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:46 Hall Probe Field Measurement, B = -0.015900 T 16:35:53 Move Stage, position = 0.030000 16:35:55 Stage Position Measurement, pos = 0.030000 m 16:35:56 Magnet Current, Imag = 150.0418 A Vtrans = 1.500418 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:57 Hall Probe Field Measurement, B = -0.014410 T 16:36:04 Move Stage, position = 0.040000 16:36:06 Stage Position Measurement, pos = 0.040000 m 16:36:07 Magnet Current, Imag = 150.0318 A Vtrans = 1.500318 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:36:07 Hall Probe Field Measurement, B = -0.013060 T 16:36:14 Move Stage, position = 0.050000 16:36:16 Stage Position Measurement, pos = 0.050000 m 16:36:17 Magnet Current, Imag = 150.0371 A Vtrans = 1.500371 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:36:18 Hall Probe Field Measurement, B = -0.011730 T 16:36:25 Move Stage, position = 0.060000 16:36:27 Stage Position Measurement, pos = 0.060000 m 16:36:28 Magnet Current, Imag = 150.0351 A Vtrans = 1.500351 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:36:28 Hall Probe Field Measurement, B = -0.010450 T 16:36:35 Move Stage, position = 0.070000 16:36:37 Stage Position Measurement, pos = 0.070000 m 16:36:38 Magnet Current, Imag = 150.0435 A Vtrans = 1.500435 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:36:39 Hall Probe Field Measurement, B = -0.009160 T 16:36:46 Move Stage, position = 0.080000 16:36:47 Stage Position Measurement, pos = 0.080000 m 16:36:49 Magnet Current, Imag = 150.0317 A Vtrans = 1.500317 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:36:49 Hall Probe Field Measurement, B = -0.007740 T 16:36:56 Move Stage, position = 0.090000 16:36:58 Stage Position Measurement, pos = 0.090000 m 16:36:59 Magnet Current, Imag = 150.0382 A Vtrans = 1.500382 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:37:00 Hall Probe Field Measurement, B = -0.006080 T 16:37:07 Move Stage, position = 0.100000 16:37:08 Stage Position Measurement, pos = 0.100000 m 16:37:10 Magnet Current, Imag = 150.0360 A Vtrans = 1.500360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:37:10 Hall Probe Field Measurement, B = -0.004310 T 16:37:17 Move Stage, position = 0.110000 16:37:19 Stage Position Measurement, pos = 0.110000 m 16:37:20 Magnet Current, Imag = 150.0357 A Vtrans = 1.500357 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:37:21 Hall Probe Field Measurement, B = -0.002720 T 16:37:28 Move Stage, position = 0.120000 16:37:29 Stage Position Measurement, pos = 0.120000 m 16:37:31 Magnet Current, Imag = 150.0385 A Vtrans = 1.500385 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:37:31 Hall Probe Field Measurement, B = -0.001580 T 16:37:38 Move Stage, position = 0.130000 16:37:40 Stage Position Measurement, pos = 0.130000 m 16:37:41 Magnet Current, Imag = 150.0266 A Vtrans = 1.500266 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:37:42 Hall Probe Field Measurement, B = -0.000860 T 16:37:49 Move Stage, position = 0.140000 16:37:50 Stage Position Measurement, pos = 0.140000 m 16:37:52 Magnet Current, Imag = 150.0343 A Vtrans = 1.500343 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:37:52 Hall Probe Field Measurement, B = -0.000460 T 16:37:59 Move Stage, position = 0.150000 16:38:01 Stage Position Measurement, pos = 0.150000 m 16:38:02 Magnet Current, Imag = 150.0282 A Vtrans = 1.500282 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:38:02 Hall Probe Field Measurement, B = -0.000240 T 16:38:10 Move Stage, position = 0.160000 16:38:11 Stage Position Measurement, pos = 0.160000 m 16:38:12 Magnet Current, Imag = 150.0318 A Vtrans = 1.500318 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:38:14 Hall Probe Field Measurement, B = -0.000130 T 16:38:21 Move Stage, position = 0.170000 16:38:22 Stage Position Measurement, pos = 0.170000 m 16:38:24 Magnet Current, Imag = 150.0319 A Vtrans = 1.500319 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:38:24 Hall Probe Field Measurement, B = -0.000070 T 16:38:31 Move Stage, position = 0.180000 16:38:33 Stage Position Measurement, pos = 0.180000 m 16:38:34 Magnet Current, Imag = 150.0355 A Vtrans = 1.500355 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:38:34 Hall Probe Field Measurement, B = -0.000030 T 16:38:42 Move Stage, position = 0.190000 16:38:43 Stage Position Measurement, pos = 0.190000 m 16:38:45 Magnet Current, Imag = 150.0381 A Vtrans = 1.500381 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:38:45 Hall Probe Field Measurement, B = -0.000010 T 16:38:52 Move Stage, position = 0.200000 16:38:54 Stage Position Measurement, pos = 0.200000 m 16:38:55 Magnet Current, Imag = 150.0267 A Vtrans = 1.500267 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:38:57 Hall Probe Field Measurement, B = 0.000000 T 16:39:04 Move Stage, position = 0.210000 16:39:06 Stage Position Measurement, pos = 0.210000 m 16:39:07 Magnet Current, Imag = 150.0395 A Vtrans = 1.500395 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:39:08 Hall Probe Field Measurement, B = 0.000010 T 16:39:16 Move Stage, position = 0.220000 16:39:17 Stage Position Measurement, pos = 0.220000 m 16:39:18 Magnet Current, Imag = 150.0310 A Vtrans = 1.500310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:39:21 Hall Probe Field Measurement, B = 0.000000 T 16:39:28 Move Stage, position = 0.230000 16:39:29 Stage Position Measurement, pos = 0.230000 m 16:39:31 Magnet Current, Imag = 150.0281 A Vtrans = 1.500281 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:39:33 Hall Probe Field Measurement, B = 0.000000 T 16:39:40 Move Stage, position = 0.240000 16:39:42 Stage Position Measurement, pos = 0.240000 m 16:39:43 Magnet Current, Imag = 150.0403 A Vtrans = 1.500403 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:39:45 Hall Probe Field Measurement, B = 0.000000 T 16:39:52 Move Stage, position = 0.250000 16:39:54 Stage Position Measurement, pos = 0.250000 m 16:39:55 Magnet Current, Imag = 150.0305 A Vtrans = 1.500305 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:39:57 Hall Probe Field Measurement, B = 0.000000 T 16:40:52 Move Stage, position = 0.000000 16:40:53 Magnet current ramping to 0.0000 A...