SLAC Magnetic Measurements Date: 03-08-2004 Time: 14:52:25 Project: Orion Magnet Type: solenoid Magnet Name: Ecomp Serial Number: Run Number: 34 Measurement Device: B9900 Hall probe Operator: keh Comment: -10 mm in y, +/- 25cm in z Standardization: 4 cycles from 0.0 A to 220.0 A to 0.0 A Test Currents (A): 20.0 150.0 220.0 14:52:45 Stage Zeroed 14:52:45 MoveZ Devices: Move Device = SXDRIVE, Read Device = SXDRIVE 14:53:42 Move Stage, position = -0.250000 14:55:24 Hall Probe Zeroed 14:55:24 Hall Probe Type Being Used, type = B9900 14:56:37 Move Stage, position = 0.000000 14:56:38 Initial Zero Current Measurement, Imag_zero = 0.0000 A 14:56:42 Hall Probe Range Set, range = 4 14:56:42 Magnet current ramping to 220.0000 A... 14:59:18 Magnet current ramping to 0.0000 A... 15:01:54 Magnet current ramping to 220.0000 A... 15:04:30 Magnet current ramping to 0.0000 A... 15:07:06 Magnet current ramping to 220.0000 A... 15:09:43 Magnet current ramping to 0.0000 A... 15:12:18 Magnet current ramping to 220.0000 A... 15:14:55 Magnet current ramping to 0.0000 A... 15:17:31 Magnet current ramping to 20.0000 A... 15:19:09 Move Stage, position = -0.250000 15:19:11 Stage Position Measurement, pos = -0.250000 m 15:19:13 Magnet Current, Imag = 19.8662 A Vtrans = 0.198662 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:19:13 Hall Probe Field Measurement, B = -0.000010 T 15:19:20 Move Stage, position = -0.240000 15:19:22 Stage Position Measurement, pos = -0.240000 m 15:19:24 Magnet Current, Imag = 19.8669 A Vtrans = 0.198669 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:19:24 Hall Probe Field Measurement, B = -0.000020 T 15:19:31 Move Stage, position = -0.230000 15:19:33 Stage Position Measurement, pos = -0.230000 m 15:19:34 Magnet Current, Imag = 19.8666 A Vtrans = 0.198666 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:19:35 Hall Probe Field Measurement, B = -0.000020 T 15:19:42 Move Stage, position = -0.220000 15:19:44 Stage Position Measurement, pos = -0.220000 m 15:19:45 Magnet Current, Imag = 19.8671 A Vtrans = 0.198672 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:19:46 Hall Probe Field Measurement, B = -0.000030 T 15:19:53 Move Stage, position = -0.210000 15:19:54 Stage Position Measurement, pos = -0.210000 m 15:19:56 Magnet Current, Imag = 19.8654 A Vtrans = 0.198654 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:19:57 Hall Probe Field Measurement, B = -0.000060 T 15:20:04 Move Stage, position = -0.200000 15:20:05 Stage Position Measurement, pos = -0.200000 m 15:20:07 Magnet Current, Imag = 19.8649 A Vtrans = 0.198649 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:20:07 Hall Probe Field Measurement, B = -0.000100 T 15:20:14 Move Stage, position = -0.190000 15:20:16 Stage Position Measurement, pos = -0.190000 m 15:20:18 Magnet Current, Imag = 19.8666 A Vtrans = 0.198665 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:20:18 Hall Probe Field Measurement, B = -0.000150 T 15:20:25 Move Stage, position = -0.180000 15:20:27 Stage Position Measurement, pos = -0.180000 m 15:20:29 Magnet Current, Imag = 19.8647 A Vtrans = 0.198647 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:20:29 Hall Probe Field Measurement, B = -0.000210 T 15:20:36 Move Stage, position = -0.170000 15:20:38 Stage Position Measurement, pos = -0.170000 m 15:20:39 Magnet Current, Imag = 19.8690 A Vtrans = 0.198690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:20:40 Hall Probe Field Measurement, B = -0.000340 T 15:20:47 Move Stage, position = -0.160000 15:20:49 Stage Position Measurement, pos = -0.160000 m 15:20:50 Magnet Current, Imag = 19.8651 A Vtrans = 0.198651 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:20:51 Hall Probe Field Measurement, B = -0.000540 T 15:20:58 Move Stage, position = -0.150000 15:21:00 Stage Position Measurement, pos = -0.150000 m 15:21:01 Magnet Current, Imag = 19.8658 A Vtrans = 0.198658 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:21:02 Hall Probe Field Measurement, B = -0.000890 T 15:21:09 Move Stage, position = -0.140000 15:21:10 Stage Position Measurement, pos = -0.140000 m 15:21:12 Magnet Current, Imag = 19.8646 A Vtrans = 0.198646 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:21:13 Hall Probe Field Measurement, B = -0.001540 T 15:21:20 Move Stage, position = -0.130000 15:21:21 Stage Position Measurement, pos = -0.130000 m 15:21:23 Magnet Current, Imag = 19.8638 A Vtrans = 0.198638 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:21:23 Hall Probe Field Measurement, B = -0.002720 T 15:21:30 Move Stage, position = -0.120000 15:21:32 Stage Position Measurement, pos = -0.120000 m 15:21:34 Magnet Current, Imag = 19.8661 A Vtrans = 0.198661 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:21:36 Hall Probe Field Measurement, B = -0.004870 T 15:21:43 Move Stage, position = -0.110000 15:21:44 Stage Position Measurement, pos = -0.110000 m 15:21:46 Magnet Current, Imag = 19.8671 A Vtrans = 0.198672 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:21:47 Hall Probe Field Measurement, B = -0.008380 T 15:21:54 Move Stage, position = -0.100000 15:21:55 Stage Position Measurement, pos = -0.100000 m 15:21:57 Magnet Current, Imag = 19.8675 A Vtrans = 0.198675 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:21:57 Hall Probe Field Measurement, B = -0.013310 T 15:22:05 Move Stage, position = -0.090000 15:22:06 Stage Position Measurement, pos = -0.090000 m 15:22:08 Magnet Current, Imag = 19.8663 A Vtrans = 0.198663 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:22:08 Hall Probe Field Measurement, B = -0.018570 T 15:22:15 Move Stage, position = -0.080000 15:22:17 Stage Position Measurement, pos = -0.080000 m 15:22:19 Magnet Current, Imag = 19.8681 A Vtrans = 0.198681 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:22:19 Hall Probe Field Measurement, B = -0.022850 T 15:22:26 Move Stage, position = -0.070000 15:22:28 Stage Position Measurement, pos = -0.070000 m 15:22:30 Magnet Current, Imag = 19.8631 A Vtrans = 0.198631 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:22:30 Hall Probe Field Measurement, B = -0.025750 T 15:22:37 Move Stage, position = -0.060000 15:22:39 Stage Position Measurement, pos = -0.060000 m 15:22:41 Magnet Current, Imag = 19.8663 A Vtrans = 0.198663 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:22:41 Hall Probe Field Measurement, B = -0.027530 T 15:22:48 Move Stage, position = -0.050000 15:22:50 Stage Position Measurement, pos = -0.050000 m 15:22:51 Magnet Current, Imag = 19.8676 A Vtrans = 0.198676 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:22:52 Hall Probe Field Measurement, B = -0.028550 T 15:22:59 Move Stage, position = -0.040000 15:23:01 Stage Position Measurement, pos = -0.040000 m 15:23:02 Magnet Current, Imag = 19.8705 A Vtrans = 0.198705 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:03 Hall Probe Field Measurement, B = -0.029140 T 15:23:10 Move Stage, position = -0.030000 15:23:12 Stage Position Measurement, pos = -0.030000 m 15:23:13 Magnet Current, Imag = 19.8637 A Vtrans = 0.198637 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:14 Hall Probe Field Measurement, B = -0.029460 T 15:23:21 Move Stage, position = -0.020000 15:23:22 Stage Position Measurement, pos = -0.020000 m 15:23:24 Magnet Current, Imag = 19.8695 A Vtrans = 0.198695 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:25 Hall Probe Field Measurement, B = -0.029650 T 15:23:32 Move Stage, position = -0.010000 15:23:33 Stage Position Measurement, pos = -0.010000 m 15:23:35 Magnet Current, Imag = 19.8671 A Vtrans = 0.198671 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:35 Hall Probe Field Measurement, B = -0.029730 T 15:23:43 Move Stage, position = 0.000000 15:23:44 Stage Position Measurement, pos = 0.000000 m 15:23:46 Magnet Current, Imag = 19.8649 A Vtrans = 0.198649 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:46 Hall Probe Field Measurement, B = -0.029720 T 15:23:53 Move Stage, position = 0.010000 15:23:55 Stage Position Measurement, pos = 0.010000 m 15:23:57 Magnet Current, Imag = 19.8630 A Vtrans = 0.198630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:57 Hall Probe Field Measurement, B = -0.029650 T 15:24:04 Move Stage, position = 0.020000 15:24:06 Stage Position Measurement, pos = 0.020000 m 15:24:08 Magnet Current, Imag = 19.8639 A Vtrans = 0.198639 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:24:08 Hall Probe Field Measurement, B = -0.029500 T 15:24:15 Move Stage, position = 0.030000 15:24:17 Stage Position Measurement, pos = 0.030000 m 15:24:18 Magnet Current, Imag = 19.8664 A Vtrans = 0.198664 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:24:19 Hall Probe Field Measurement, B = -0.029290 T 15:24:26 Move Stage, position = 0.040000 15:24:28 Stage Position Measurement, pos = 0.040000 m 15:24:29 Magnet Current, Imag = 19.8683 A Vtrans = 0.198683 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:24:30 Hall Probe Field Measurement, B = -0.028940 T 15:24:37 Move Stage, position = 0.050000 15:24:39 Stage Position Measurement, pos = 0.050000 m 15:24:40 Magnet Current, Imag = 19.8184 A Vtrans = 0.198184 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:24:41 Hall Probe Field Measurement, B = -0.028300 T 15:24:48 Move Stage, position = 0.060000 15:24:49 Stage Position Measurement, pos = 0.060000 m 15:24:51 Magnet Current, Imag = 19.8553 A Vtrans = 0.198553 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:24:52 Hall Probe Field Measurement, B = -0.027290 T 15:24:59 Move Stage, position = 0.070000 15:25:00 Stage Position Measurement, pos = 0.070000 m 15:25:02 Magnet Current, Imag = 19.8732 A Vtrans = 0.198733 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:25:02 Hall Probe Field Measurement, B = -0.025500 T 15:25:10 Move Stage, position = 0.080000 15:25:11 Stage Position Measurement, pos = 0.080000 m 15:25:13 Magnet Current, Imag = 19.8606 A Vtrans = 0.198606 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:25:13 Hall Probe Field Measurement, B = -0.022550 T 15:25:20 Move Stage, position = 0.090000 15:25:22 Stage Position Measurement, pos = 0.090000 m 15:25:24 Magnet Current, Imag = 19.8721 A Vtrans = 0.198721 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:25:24 Hall Probe Field Measurement, B = -0.018270 T 15:25:31 Move Stage, position = 0.100000 15:25:33 Stage Position Measurement, pos = 0.100000 m 15:25:35 Magnet Current, Imag = 19.8615 A Vtrans = 0.198615 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:25:35 Hall Probe Field Measurement, B = -0.013000 T 15:25:42 Move Stage, position = 0.110000 15:25:44 Stage Position Measurement, pos = 0.110000 m 15:25:45 Magnet Current, Imag = 19.8538 A Vtrans = 0.198538 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:25:46 Hall Probe Field Measurement, B = -0.008140 T 15:25:53 Move Stage, position = 0.120000 15:25:55 Stage Position Measurement, pos = 0.120000 m 15:25:56 Magnet Current, Imag = 19.8611 A Vtrans = 0.198611 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:25:57 Hall Probe Field Measurement, B = -0.004700 T 15:26:04 Move Stage, position = 0.130000 15:26:06 Stage Position Measurement, pos = 0.130000 m 15:26:07 Magnet Current, Imag = 19.8590 A Vtrans = 0.198590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:26:09 Hall Probe Field Measurement, B = -0.002630 T 15:26:16 Move Stage, position = 0.140000 15:26:18 Stage Position Measurement, pos = 0.140000 m 15:26:20 Magnet Current, Imag = 19.8607 A Vtrans = 0.198607 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:26:20 Hall Probe Field Measurement, B = -0.001490 T 15:26:27 Move Stage, position = 0.150000 15:26:29 Stage Position Measurement, pos = 0.150000 m 15:26:30 Magnet Current, Imag = 19.8629 A Vtrans = 0.198629 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:26:31 Hall Probe Field Measurement, B = -0.000870 T 15:26:38 Move Stage, position = 0.160000 15:26:40 Stage Position Measurement, pos = 0.160000 m 15:26:41 Magnet Current, Imag = 19.8636 A Vtrans = 0.198636 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:26:42 Hall Probe Field Measurement, B = -0.000520 T 15:26:49 Move Stage, position = 0.170000 15:26:51 Stage Position Measurement, pos = 0.170000 m 15:26:52 Magnet Current, Imag = 19.8660 A Vtrans = 0.198660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:26:53 Hall Probe Field Measurement, B = -0.000320 T 15:27:00 Move Stage, position = 0.180000 15:27:01 Stage Position Measurement, pos = 0.180000 m 15:27:03 Magnet Current, Imag = 19.8694 A Vtrans = 0.198694 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:27:04 Hall Probe Field Measurement, B = -0.000210 T 15:27:11 Move Stage, position = 0.190000 15:27:12 Stage Position Measurement, pos = 0.190000 m 15:27:14 Magnet Current, Imag = 19.8568 A Vtrans = 0.198568 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:27:14 Hall Probe Field Measurement, B = -0.000130 T 15:27:22 Move Stage, position = 0.200000 15:27:23 Stage Position Measurement, pos = 0.200000 m 15:27:25 Magnet Current, Imag = 19.8609 A Vtrans = 0.198609 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:27:25 Hall Probe Field Measurement, B = -0.000100 T 15:27:32 Move Stage, position = 0.210000 15:27:34 Stage Position Measurement, pos = 0.210000 m 15:27:36 Magnet Current, Imag = 19.8591 A Vtrans = 0.198591 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:27:36 Hall Probe Field Measurement, B = -0.000060 T 15:27:43 Move Stage, position = 0.220000 15:27:45 Stage Position Measurement, pos = 0.220000 m 15:27:47 Magnet Current, Imag = 19.8626 A Vtrans = 0.198626 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:27:47 Hall Probe Field Measurement, B = -0.000050 T 15:27:54 Move Stage, position = 0.230000 15:27:56 Stage Position Measurement, pos = 0.230000 m 15:27:58 Magnet Current, Imag = 19.8599 A Vtrans = 0.198599 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:27:58 Hall Probe Field Measurement, B = -0.000020 T 15:28:05 Move Stage, position = 0.240000 15:28:07 Stage Position Measurement, pos = 0.240000 m 15:28:08 Magnet Current, Imag = 19.8656 A Vtrans = 0.198656 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:09 Hall Probe Field Measurement, B = -0.000020 T 15:28:16 Move Stage, position = 0.250000 15:28:18 Stage Position Measurement, pos = 0.250000 m 15:28:19 Magnet Current, Imag = 19.8628 A Vtrans = 0.198628 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:20 Hall Probe Field Measurement, B = -0.000010 T 15:29:15 Move Stage, position = 0.000000 15:29:15 Magnet current ramping to 150.0000 A... 15:31:55 Move Stage, position = -0.250000 15:31:57 Stage Position Measurement, pos = -0.250000 m 15:31:58 Magnet Current, Imag = 149.8527 A Vtrans = 1.498527 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:31:59 Hall Probe Field Measurement, B = -0.000440 T 15:32:06 Move Stage, position = -0.240000 15:32:07 Stage Position Measurement, pos = -0.240000 m 15:32:09 Magnet Current, Imag = 149.8596 A Vtrans = 1.498596 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:09 Hall Probe Field Measurement, B = -0.000520 T 15:32:16 Move Stage, position = -0.230000 15:32:18 Stage Position Measurement, pos = -0.230000 m 15:32:19 Magnet Current, Imag = 149.8494 A Vtrans = 1.498494 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:20 Hall Probe Field Measurement, B = -0.000630 T 15:32:27 Move Stage, position = -0.220000 15:32:28 Stage Position Measurement, pos = -0.220000 m 15:32:30 Magnet Current, Imag = 149.8461 A Vtrans = 1.498461 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:30 Hall Probe Field Measurement, B = -0.000780 T 15:32:37 Move Stage, position = -0.210000 15:32:39 Stage Position Measurement, pos = -0.210000 m 15:32:40 Magnet Current, Imag = 149.8505 A Vtrans = 1.498505 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:40 Hall Probe Field Measurement, B = -0.000960 T 15:32:48 Move Stage, position = -0.200000 15:32:49 Stage Position Measurement, pos = -0.200000 m 15:32:50 Magnet Current, Imag = 149.8423 A Vtrans = 1.498423 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:51 Hall Probe Field Measurement, B = -0.001240 T 15:32:58 Move Stage, position = -0.190000 15:33:00 Stage Position Measurement, pos = -0.190000 m 15:33:01 Magnet Current, Imag = 149.8513 A Vtrans = 1.498513 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:33:01 Hall Probe Field Measurement, B = -0.001650 T 15:33:08 Move Stage, position = -0.180000 15:33:10 Stage Position Measurement, pos = -0.180000 m 15:33:11 Magnet Current, Imag = 149.8503 A Vtrans = 1.498503 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:33:12 Hall Probe Field Measurement, B = -0.002270 T 15:33:19 Move Stage, position = -0.170000 15:33:20 Stage Position Measurement, pos = -0.170000 m 15:33:22 Magnet Current, Imag = 149.8435 A Vtrans = 1.498435 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:33:22 Hall Probe Field Measurement, B = -0.003230 T 15:33:29 Move Stage, position = -0.160000 15:33:31 Stage Position Measurement, pos = -0.160000 m 15:33:32 Magnet Current, Imag = 149.8506 A Vtrans = 1.498506 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:33:33 Hall Probe Field Measurement, B = -0.004820 T 15:33:40 Move Stage, position = -0.150000 15:33:41 Stage Position Measurement, pos = -0.150000 m 15:33:43 Magnet Current, Imag = 149.8512 A Vtrans = 1.498512 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:33:43 Hall Probe Field Measurement, B = -0.007510 T 15:33:50 Move Stage, position = -0.140000 15:33:52 Stage Position Measurement, pos = -0.140000 m 15:33:53 Magnet Current, Imag = 149.8546 A Vtrans = 1.498546 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:33:53 Hall Probe Field Measurement, B = -0.012340 T 15:34:01 Move Stage, position = -0.130000 15:34:02 Stage Position Measurement, pos = -0.130000 m 15:34:03 Magnet Current, Imag = 149.8513 A Vtrans = 1.498513 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:04 Hall Probe Field Measurement, B = -0.021140 T 15:34:11 Move Stage, position = -0.120000 15:34:13 Stage Position Measurement, pos = -0.120000 m 15:34:14 Magnet Current, Imag = 149.8495 A Vtrans = 1.498495 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:14 Hall Probe Field Measurement, B = -0.037070 T 15:34:21 Move Stage, position = -0.110000 15:34:23 Stage Position Measurement, pos = -0.110000 m 15:34:24 Magnet Current, Imag = 149.8489 A Vtrans = 1.498489 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:25 Hall Probe Field Measurement, B = -0.063130 T 15:34:32 Move Stage, position = -0.100000 15:34:33 Stage Position Measurement, pos = -0.100000 m 15:34:35 Magnet Current, Imag = 149.8518 A Vtrans = 1.498518 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:35 Hall Probe Field Measurement, B = -0.099680 T 15:34:42 Move Stage, position = -0.090000 15:34:44 Stage Position Measurement, pos = -0.090000 m 15:34:45 Magnet Current, Imag = 149.8498 A Vtrans = 1.498498 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:46 Hall Probe Field Measurement, B = -0.138850 T 15:34:53 Move Stage, position = -0.080000 15:34:54 Stage Position Measurement, pos = -0.080000 m 15:34:55 Magnet Current, Imag = 149.8497 A Vtrans = 1.498497 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:56 Hall Probe Field Measurement, B = -0.170710 T 15:35:03 Move Stage, position = -0.070000 15:35:05 Stage Position Measurement, pos = -0.070000 m 15:35:06 Magnet Current, Imag = 149.8497 A Vtrans = 1.498497 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:35:06 Hall Probe Field Measurement, B = -0.192380 T 15:35:13 Move Stage, position = -0.060000 15:35:15 Stage Position Measurement, pos = -0.060000 m 15:35:16 Magnet Current, Imag = 149.8519 A Vtrans = 1.498519 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:35:17 Hall Probe Field Measurement, B = -0.205790 T 15:35:24 Move Stage, position = -0.050000 15:35:26 Stage Position Measurement, pos = -0.050000 m 15:35:27 Magnet Current, Imag = 149.8497 A Vtrans = 1.498497 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:35:27 Hall Probe Field Measurement, B = -0.213560 T 15:35:34 Move Stage, position = -0.040000 15:35:36 Stage Position Measurement, pos = -0.040000 m 15:35:37 Magnet Current, Imag = 149.8481 A Vtrans = 1.498481 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:35:38 Hall Probe Field Measurement, B = -0.218040 T 15:35:45 Move Stage, position = -0.030000 15:35:46 Stage Position Measurement, pos = -0.030000 m 15:35:48 Magnet Current, Imag = 149.8529 A Vtrans = 1.498529 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:35:48 Hall Probe Field Measurement, B = -0.220510 T 15:35:55 Move Stage, position = -0.020000 15:35:57 Stage Position Measurement, pos = -0.020000 m 15:35:58 Magnet Current, Imag = 149.8507 A Vtrans = 1.498507 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:35:59 Hall Probe Field Measurement, B = -0.221850 T 15:36:06 Move Stage, position = -0.010000 15:36:07 Stage Position Measurement, pos = -0.010000 m 15:36:09 Magnet Current, Imag = 149.8506 A Vtrans = 1.498506 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:09 Hall Probe Field Measurement, B = -0.222430 T 15:36:16 Move Stage, position = 0.000000 15:36:18 Stage Position Measurement, pos = 0.000000 m 15:36:19 Magnet Current, Imag = 149.8475 A Vtrans = 1.498475 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:19 Hall Probe Field Measurement, B = -0.222280 T 15:36:27 Move Stage, position = 0.010000 15:36:28 Stage Position Measurement, pos = 0.010000 m 15:36:29 Magnet Current, Imag = 149.8518 A Vtrans = 1.498518 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:30 Hall Probe Field Measurement, B = -0.221860 T 15:36:37 Move Stage, position = 0.020000 15:36:39 Stage Position Measurement, pos = 0.020000 m 15:36:40 Magnet Current, Imag = 149.8525 A Vtrans = 1.498525 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:40 Hall Probe Field Measurement, B = -0.220880 T 15:36:47 Move Stage, position = 0.030000 15:36:49 Stage Position Measurement, pos = 0.030000 m 15:36:50 Magnet Current, Imag = 149.8542 A Vtrans = 1.498542 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:51 Hall Probe Field Measurement, B = -0.219350 T 15:36:58 Move Stage, position = 0.040000 15:37:00 Stage Position Measurement, pos = 0.040000 m 15:37:01 Magnet Current, Imag = 149.8514 A Vtrans = 1.498514 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:01 Hall Probe Field Measurement, B = -0.216700 T 15:37:08 Move Stage, position = 0.050000 15:37:10 Stage Position Measurement, pos = 0.050000 m 15:37:11 Magnet Current, Imag = 149.8501 A Vtrans = 1.498501 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:12 Hall Probe Field Measurement, B = -0.212020 T 15:37:19 Move Stage, position = 0.060000 15:37:20 Stage Position Measurement, pos = 0.060000 m 15:37:22 Magnet Current, Imag = 149.8472 A Vtrans = 1.498472 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:22 Hall Probe Field Measurement, B = -0.204030 T 15:37:29 Move Stage, position = 0.070000 15:37:31 Stage Position Measurement, pos = 0.070000 m 15:37:32 Magnet Current, Imag = 149.8501 A Vtrans = 1.498501 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:33 Hall Probe Field Measurement, B = -0.190390 T 15:37:40 Move Stage, position = 0.080000 15:37:41 Stage Position Measurement, pos = 0.080000 m 15:37:43 Magnet Current, Imag = 149.8523 A Vtrans = 1.498523 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:43 Hall Probe Field Measurement, B = -0.168540 T 15:37:50 Move Stage, position = 0.090000 15:37:52 Stage Position Measurement, pos = 0.090000 m 15:37:53 Magnet Current, Imag = 149.8467 A Vtrans = 1.498467 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:53 Hall Probe Field Measurement, B = -0.136450 T 15:38:01 Move Stage, position = 0.100000 15:38:02 Stage Position Measurement, pos = 0.100000 m 15:38:03 Magnet Current, Imag = 149.8523 A Vtrans = 1.498523 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:04 Hall Probe Field Measurement, B = -0.097350 T 15:38:11 Move Stage, position = 0.110000 15:38:13 Stage Position Measurement, pos = 0.110000 m 15:38:14 Magnet Current, Imag = 149.8491 A Vtrans = 1.498491 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:14 Hall Probe Field Measurement, B = -0.061380 T 15:38:21 Move Stage, position = 0.120000 15:38:23 Stage Position Measurement, pos = 0.120000 m 15:38:24 Magnet Current, Imag = 149.8501 A Vtrans = 1.498501 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:25 Hall Probe Field Measurement, B = -0.035870 T 15:38:32 Move Stage, position = 0.130000 15:38:33 Stage Position Measurement, pos = 0.130000 m 15:38:35 Magnet Current, Imag = 149.8477 A Vtrans = 1.498477 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:35 Hall Probe Field Measurement, B = -0.020440 T 15:38:42 Move Stage, position = 0.140000 15:38:44 Stage Position Measurement, pos = 0.140000 m 15:38:45 Magnet Current, Imag = 149.8485 A Vtrans = 1.498485 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:46 Hall Probe Field Measurement, B = -0.011960 T 15:38:53 Move Stage, position = 0.150000 15:38:54 Stage Position Measurement, pos = 0.150000 m 15:38:56 Magnet Current, Imag = 149.8526 A Vtrans = 1.498526 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:56 Hall Probe Field Measurement, B = -0.007290 T 15:39:03 Move Stage, position = 0.160000 15:39:05 Stage Position Measurement, pos = 0.160000 m 15:39:06 Magnet Current, Imag = 149.8496 A Vtrans = 1.498496 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:06 Hall Probe Field Measurement, B = -0.004670 T 15:39:14 Move Stage, position = 0.170000 15:39:15 Stage Position Measurement, pos = 0.170000 m 15:39:16 Magnet Current, Imag = 149.8483 A Vtrans = 1.498483 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:17 Hall Probe Field Measurement, B = -0.003140 T 15:39:24 Move Stage, position = 0.180000 15:39:26 Stage Position Measurement, pos = 0.180000 m 15:39:27 Magnet Current, Imag = 149.8534 A Vtrans = 1.498534 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:27 Hall Probe Field Measurement, B = -0.002210 T 15:39:35 Move Stage, position = 0.190000 15:39:36 Stage Position Measurement, pos = 0.190000 m 15:39:37 Magnet Current, Imag = 149.8525 A Vtrans = 1.498525 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:38 Hall Probe Field Measurement, B = -0.001610 T 15:39:45 Move Stage, position = 0.200000 15:39:47 Stage Position Measurement, pos = 0.200000 m 15:39:48 Magnet Current, Imag = 149.8530 A Vtrans = 1.498530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:48 Hall Probe Field Measurement, B = -0.001230 T 15:39:55 Move Stage, position = 0.210000 15:39:57 Stage Position Measurement, pos = 0.210000 m 15:39:58 Magnet Current, Imag = 149.8502 A Vtrans = 1.498502 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:59 Hall Probe Field Measurement, B = -0.000950 T 15:40:06 Move Stage, position = 0.220000 15:40:08 Stage Position Measurement, pos = 0.220000 m 15:40:09 Magnet Current, Imag = 149.8516 A Vtrans = 1.498516 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:09 Hall Probe Field Measurement, B = -0.000770 T 15:40:16 Move Stage, position = 0.230000 15:40:18 Stage Position Measurement, pos = 0.230000 m 15:40:19 Magnet Current, Imag = 149.8506 A Vtrans = 1.498506 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:20 Hall Probe Field Measurement, B = -0.000620 T 15:40:27 Move Stage, position = 0.240000 15:40:28 Stage Position Measurement, pos = 0.240000 m 15:40:30 Magnet Current, Imag = 149.8510 A Vtrans = 1.498510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:30 Hall Probe Field Measurement, B = -0.000520 T 15:40:37 Move Stage, position = 0.250000 15:40:39 Stage Position Measurement, pos = 0.250000 m 15:40:40 Magnet Current, Imag = 149.8536 A Vtrans = 1.498536 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:41 Hall Probe Field Measurement, B = -0.000440 T 15:41:36 Move Stage, position = 0.000000 15:41:36 Magnet current ramping to 220.0000 A... 15:43:42 Move Stage, position = -0.250000 15:43:43 Stage Position Measurement, pos = -0.250000 m 15:43:45 Magnet Current, Imag = 219.8402 A Vtrans = 2.198402 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:45 Hall Probe Field Measurement, B = -0.000700 T 15:43:53 Move Stage, position = -0.240000 15:43:54 Stage Position Measurement, pos = -0.240000 m 15:43:55 Magnet Current, Imag = 219.8150 A Vtrans = 2.198150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:56 Hall Probe Field Measurement, B = -0.000820 T 15:44:03 Move Stage, position = -0.230000 15:44:05 Stage Position Measurement, pos = -0.230000 m 15:44:06 Magnet Current, Imag = 219.8067 A Vtrans = 2.198067 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:44:06 Hall Probe Field Measurement, B = -0.000990 T 15:44:13 Move Stage, position = -0.220000 15:44:15 Stage Position Measurement, pos = -0.220000 m 15:44:16 Magnet Current, Imag = 219.8146 A Vtrans = 2.198146 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:44:17 Hall Probe Field Measurement, B = -0.001190 T 15:44:24 Move Stage, position = -0.210000 15:44:26 Stage Position Measurement, pos = -0.210000 m 15:44:27 Magnet Current, Imag = 219.8189 A Vtrans = 2.198189 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:44:27 Hall Probe Field Measurement, B = -0.001490 T 15:44:34 Move Stage, position = -0.200000 15:44:36 Stage Position Measurement, pos = -0.200000 m 15:44:37 Magnet Current, Imag = 219.8420 A Vtrans = 2.198420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:44:38 Hall Probe Field Measurement, B = -0.001900 T 15:44:45 Move Stage, position = -0.190000 15:44:47 Stage Position Measurement, pos = -0.190000 m 15:44:48 Magnet Current, Imag = 219.8279 A Vtrans = 2.198279 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:44:48 Hall Probe Field Measurement, B = -0.002510 T 15:44:56 Move Stage, position = -0.180000 15:44:57 Stage Position Measurement, pos = -0.180000 m 15:44:58 Magnet Current, Imag = 219.8110 A Vtrans = 2.198110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:44:59 Hall Probe Field Measurement, B = -0.003400 T 15:45:06 Move Stage, position = -0.170000 15:45:08 Stage Position Measurement, pos = -0.170000 m 15:45:09 Magnet Current, Imag = 219.8281 A Vtrans = 2.198281 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:09 Hall Probe Field Measurement, B = -0.004820 T 15:45:17 Move Stage, position = -0.160000 15:45:18 Stage Position Measurement, pos = -0.160000 m 15:45:19 Magnet Current, Imag = 219.8207 A Vtrans = 2.198207 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:20 Hall Probe Field Measurement, B = -0.007140 T 15:45:27 Move Stage, position = -0.150000 15:45:29 Stage Position Measurement, pos = -0.150000 m 15:45:30 Magnet Current, Imag = 219.8208 A Vtrans = 2.198208 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:30 Hall Probe Field Measurement, B = -0.011100 T 15:45:37 Move Stage, position = -0.140000 15:45:39 Stage Position Measurement, pos = -0.140000 m 15:45:40 Magnet Current, Imag = 219.8140 A Vtrans = 2.198140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:41 Hall Probe Field Measurement, B = -0.018190 T 15:45:48 Move Stage, position = -0.130000 15:45:50 Stage Position Measurement, pos = -0.130000 m 15:45:51 Magnet Current, Imag = 219.8269 A Vtrans = 2.198269 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:51 Hall Probe Field Measurement, B = -0.031060 T 15:45:58 Move Stage, position = -0.120000 15:46:00 Stage Position Measurement, pos = -0.120000 m 15:46:01 Magnet Current, Imag = 219.8162 A Vtrans = 2.198162 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:46:02 Hall Probe Field Measurement, B = -0.054410 T 15:46:09 Move Stage, position = -0.110000 15:46:10 Stage Position Measurement, pos = -0.110000 m 15:46:12 Magnet Current, Imag = 219.8126 A Vtrans = 2.198126 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:46:12 Hall Probe Field Measurement, B = -0.092610 T 15:46:19 Move Stage, position = -0.100000 15:46:21 Stage Position Measurement, pos = -0.100000 m 15:46:22 Magnet Current, Imag = 219.7999 A Vtrans = 2.197999 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:46:23 Hall Probe Field Measurement, B = -0.146100 T 15:46:30 Move Stage, position = -0.090000 15:46:31 Stage Position Measurement, pos = -0.090000 m 15:46:33 Magnet Current, Imag = 219.8269 A Vtrans = 2.198269 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:46:33 Hall Probe Field Measurement, B = -0.203540 T 15:46:40 Move Stage, position = -0.080000 15:46:42 Stage Position Measurement, pos = -0.080000 m 15:46:43 Magnet Current, Imag = 219.8135 A Vtrans = 2.198135 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:46:43 Hall Probe Field Measurement, B = -0.250230 T 15:46:51 Move Stage, position = -0.070000 15:46:52 Stage Position Measurement, pos = -0.070000 m 15:46:53 Magnet Current, Imag = 219.8165 A Vtrans = 2.198165 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:46:54 Hall Probe Field Measurement, B = -0.282010 T 15:47:01 Move Stage, position = -0.060000 15:47:03 Stage Position Measurement, pos = -0.060000 m 15:47:04 Magnet Current, Imag = 219.8105 A Vtrans = 2.198105 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:04 Hall Probe Field Measurement, B = -0.301660 T 15:47:11 Move Stage, position = -0.050000 15:47:13 Stage Position Measurement, pos = -0.050000 m 15:47:14 Magnet Current, Imag = 219.8196 A Vtrans = 2.198196 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:15 Hall Probe Field Measurement, B = -0.313070 T 15:47:22 Move Stage, position = -0.040000 15:47:24 Stage Position Measurement, pos = -0.040000 m 15:47:25 Magnet Current, Imag = 219.8145 A Vtrans = 2.198145 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:25 Hall Probe Field Measurement, B = -0.319650 T 15:47:32 Move Stage, position = -0.030000 15:47:34 Stage Position Measurement, pos = -0.030000 m 15:47:35 Magnet Current, Imag = 219.8142 A Vtrans = 2.198142 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:36 Hall Probe Field Measurement, B = -0.323280 T 15:47:43 Move Stage, position = -0.020000 15:47:44 Stage Position Measurement, pos = -0.020000 m 15:47:46 Magnet Current, Imag = 219.8149 A Vtrans = 2.198149 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:46 Hall Probe Field Measurement, B = -0.325240 T 15:47:53 Move Stage, position = -0.010000 15:47:55 Stage Position Measurement, pos = -0.010000 m 15:47:56 Magnet Current, Imag = 219.7837 A Vtrans = 2.197837 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:57 Hall Probe Field Measurement, B = -0.326090 T 15:48:04 Move Stage, position = 0.000000 15:48:05 Stage Position Measurement, pos = 0.000000 m 15:48:07 Magnet Current, Imag = 219.8128 A Vtrans = 2.198128 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:48:07 Hall Probe Field Measurement, B = -0.325900 T 15:48:14 Move Stage, position = 0.010000 15:48:16 Stage Position Measurement, pos = 0.010000 m 15:48:17 Magnet Current, Imag = 219.8137 A Vtrans = 2.198137 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:48:17 Hall Probe Field Measurement, B = -0.325260 T 15:48:25 Move Stage, position = 0.020000 15:48:26 Stage Position Measurement, pos = 0.020000 m 15:48:27 Magnet Current, Imag = 219.8151 A Vtrans = 2.198151 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:48:28 Hall Probe Field Measurement, B = -0.323810 T 15:48:35 Move Stage, position = 0.030000 15:48:37 Stage Position Measurement, pos = 0.030000 m 15:48:38 Magnet Current, Imag = 219.8117 A Vtrans = 2.198117 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:48:38 Hall Probe Field Measurement, B = -0.321590 T 15:48:45 Move Stage, position = 0.040000 15:48:47 Stage Position Measurement, pos = 0.040000 m 15:48:48 Magnet Current, Imag = 219.8158 A Vtrans = 2.198158 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:48:49 Hall Probe Field Measurement, B = -0.317710 T 15:48:56 Move Stage, position = 0.050000 15:48:57 Stage Position Measurement, pos = 0.050000 m 15:48:59 Magnet Current, Imag = 219.8249 A Vtrans = 2.198249 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:48:59 Hall Probe Field Measurement, B = -0.310840 T 15:49:06 Move Stage, position = 0.060000 15:49:08 Stage Position Measurement, pos = 0.060000 m 15:49:09 Magnet Current, Imag = 219.8127 A Vtrans = 2.198127 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:10 Hall Probe Field Measurement, B = -0.299080 T 15:49:17 Move Stage, position = 0.070000 15:49:18 Stage Position Measurement, pos = 0.070000 m 15:49:20 Magnet Current, Imag = 219.8203 A Vtrans = 2.198203 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:20 Hall Probe Field Measurement, B = -0.279080 T 15:49:27 Move Stage, position = 0.080000 15:49:29 Stage Position Measurement, pos = 0.080000 m 15:49:30 Magnet Current, Imag = 219.8122 A Vtrans = 2.198122 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:31 Hall Probe Field Measurement, B = -0.246980 T 15:49:38 Move Stage, position = 0.090000 15:49:39 Stage Position Measurement, pos = 0.090000 m 15:49:40 Magnet Current, Imag = 219.8195 A Vtrans = 2.198195 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:41 Hall Probe Field Measurement, B = -0.199950 T 15:49:48 Move Stage, position = 0.100000 15:49:50 Stage Position Measurement, pos = 0.100000 m 15:49:51 Magnet Current, Imag = 219.8167 A Vtrans = 2.198167 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:51 Hall Probe Field Measurement, B = -0.142670 T 15:49:59 Move Stage, position = 0.110000 15:50:00 Stage Position Measurement, pos = 0.110000 m 15:50:01 Magnet Current, Imag = 219.8153 A Vtrans = 2.198153 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:50:02 Hall Probe Field Measurement, B = -0.090000 T 15:50:09 Move Stage, position = 0.120000 15:50:11 Stage Position Measurement, pos = 0.120000 m 15:50:12 Magnet Current, Imag = 219.8061 A Vtrans = 2.198061 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:50:12 Hall Probe Field Measurement, B = -0.052610 T 15:50:19 Move Stage, position = 0.130000 15:50:21 Stage Position Measurement, pos = 0.130000 m 15:50:22 Magnet Current, Imag = 219.8137 A Vtrans = 2.198137 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:50:23 Hall Probe Field Measurement, B = -0.030040 T 15:50:30 Move Stage, position = 0.140000 15:50:32 Stage Position Measurement, pos = 0.140000 m 15:50:33 Magnet Current, Imag = 219.8143 A Vtrans = 2.198143 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:50:33 Hall Probe Field Measurement, B = -0.017620 T 15:50:40 Move Stage, position = 0.150000 15:50:42 Stage Position Measurement, pos = 0.150000 m 15:50:43 Magnet Current, Imag = 219.8174 A Vtrans = 2.198174 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:50:44 Hall Probe Field Measurement, B = -0.010750 T 15:50:51 Move Stage, position = 0.160000 15:50:52 Stage Position Measurement, pos = 0.160000 m 15:50:54 Magnet Current, Imag = 219.8128 A Vtrans = 2.198128 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:50:54 Hall Probe Field Measurement, B = -0.006940 T 15:51:01 Move Stage, position = 0.170000 15:51:03 Stage Position Measurement, pos = 0.170000 m 15:51:04 Magnet Current, Imag = 219.8116 A Vtrans = 2.198116 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:05 Hall Probe Field Measurement, B = -0.004680 T 15:51:12 Move Stage, position = 0.180000 15:51:13 Stage Position Measurement, pos = 0.180000 m 15:51:15 Magnet Current, Imag = 219.8141 A Vtrans = 2.198141 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:15 Hall Probe Field Measurement, B = -0.003310 T 15:51:22 Move Stage, position = 0.190000 15:51:24 Stage Position Measurement, pos = 0.190000 m 15:51:25 Magnet Current, Imag = 219.8136 A Vtrans = 2.198136 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:25 Hall Probe Field Measurement, B = -0.002440 T 15:51:33 Move Stage, position = 0.200000 15:51:34 Stage Position Measurement, pos = 0.200000 m 15:51:35 Magnet Current, Imag = 219.8111 A Vtrans = 2.198111 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:36 Hall Probe Field Measurement, B = -0.001860 T 15:51:44 Move Stage, position = 0.210000 15:51:45 Stage Position Measurement, pos = 0.210000 m 15:51:46 Magnet Current, Imag = 219.8426 A Vtrans = 2.198426 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:47 Hall Probe Field Measurement, B = -0.001460 T 15:51:54 Move Stage, position = 0.220000 15:51:56 Stage Position Measurement, pos = 0.220000 m 15:51:57 Magnet Current, Imag = 219.8118 A Vtrans = 2.198118 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:57 Hall Probe Field Measurement, B = -0.001180 T 15:52:04 Move Stage, position = 0.230000 15:52:06 Stage Position Measurement, pos = 0.230000 m 15:52:07 Magnet Current, Imag = 219.8123 A Vtrans = 2.198123 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:52:08 Hall Probe Field Measurement, B = -0.000960 T 15:52:15 Move Stage, position = 0.240000 15:52:17 Stage Position Measurement, pos = 0.240000 m 15:52:18 Magnet Current, Imag = 219.8121 A Vtrans = 2.198121 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:52:18 Hall Probe Field Measurement, B = -0.000800 T 15:52:25 Move Stage, position = 0.250000 15:52:27 Stage Position Measurement, pos = 0.250000 m 15:52:28 Magnet Current, Imag = 219.8078 A Vtrans = 2.198078 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:52:29 Hall Probe Field Measurement, B = -0.000690 T 15:53:24 Move Stage, position = 0.000000 15:53:25 Magnet current ramping to 0.0000 A...