SLAC Magnetic Measurements Date: 07-22-2008 Time: 11:04:16 Planar Insertion Device Analysis -------------------------------- Data File Header: SLAC Magnetic Measurements Date: 07-22-2008 Time: 10:50:03 Project: LCLS Device Type: Undulator Data Type: Serial Number: L143-112000-38 DATASET Number: 1 Tuning Stage: Rough Tuning Run Number: 82 Measurement Type: Z Scans Operator: aw Comment: f.p. 0.371967, x=0.026487 y=0.00027773. 1/2 turn out at 19 x-shims. Measurement Device x: Measurement Device y: SENIS_24-06 Data File: s:\magdata\LCLS\Undulator\L143-112000-38\DATASET0001\Rough Tuning\Z Scans\Run 082\bscanz.dat Temperature (C) L143-112000-38:--> top_start 20.06 --> top_mid 20.06 --> top_end 19.95 --> bot 20.04 --> granite 19.98 --> Air 19.94 Axes position (m) X:0.026487 Y:0.000278 Initial Hall Probe Zero Measurements: Vx_0i = -0.000416 V Vy_0i = -0.000402 V Final Hall Probe Zero Measurements: Vx_0f = -0.000431 V Vy_0f = -0.000393 V Offset Correction Voff = offset+index*increment index = 0,1...19850 Vx:offset = -0.000416 V, increment = -7.332E-10 V Vy:offset = -0.000402 V, increment = 4.435E-10 V Hall Probe Calibration File: Y: C:\CVI\current_calib\SENIS_24-06\SENIS_24-06_y.ini X: c:\cvi\current_calib\HALLx_calib_poly_fit_file.dat Reference Magnet Measurements: Bx_ref = 0.0000xx (T) By_ref = 0.0000xx (T) Magnetic Field Measurements vs Z Analysis Parameters: Input file directory = S:\MagData\LCLS\Undulator\L143-112000-38\DATASET0001\Rough Tuning\Z Scans\Run 082\ Input file name = x+00000_y+000_bscanz.dat Input file type = ZVXYBXYH Correction required = 1 Correction, Bx multiplicative factor = 1.000000 Correction, By multiplicative factor = 1.000000 Correction, Bx additive constant = 0.000015 T Correction, By additive constant = 0.000000 T Correction Bxy additive file = S:\Magdata\Earth Field Correction\earth_field_corr.dat Correction Bxy additive file type = CORR_ZBXY Electron gamma = 26644.120000 Electron energy = 13.615120 Gev Nominal undulator period = 0.030000 m Nominal K value = 3.489476 Nominal radiation wavelength = 1.497703e-010 m Number of undulator poles = 226 Number of end poles (used in analysis) = 4 Cell length = 3.656000 m Nominal phase change through cell = 709.999940 rad Nominal phase of pole after end poles = 14.137167 rad Save as final result = 0 Result file directory = c:\magdata\slac_und_2\ Result file name = zscan_xn0060yp0002.dat Figures close on exit = 0 Figures visible = 1 !!!!!!!!!!!!!!!!!!!!!!!!!!!!!! The Measured Fields Were Corrected: Bx_corr = CORR_BX_MULT * Bx + CORR_BX_ADD + CORR_BX_ADD_FILE By_corr = CORR_BY_MULT * By + CORR_BY_ADD + CORR_BY_ADD_FILE Parameters: CORR_BX_MULT = 1.000000 CORR_BY_MULT = 1.000000 CORR_BX_ADD = 0.000015 T CORR_BY_ADD = 0.000000 T CORR_BX_ADD_FILE = S:\Magdata\Earth Field Correction\earth_field_corr.dat CORR_BY_ADD_FILE = S:\Magdata\Earth Field Correction\earth_field_corr.dat !!!!!!!!!!!!!!!!!!!!!!!!!!!!!! Peak And Zero Field Summary: Number of Poles = 226 Number of End Poles (excluded in statistics) = 4 Peak Fields: Ave = 1.272154 T, RMS = 0.005289 T Peak Field Spacing: Ave = 0.014999 m, RMS = 0.000021 m Zero Field Spacing: Ave = 0.015000 m, RMS = 0.000045 m Average Undulator Period = 0.029999 m Hall Probe Overall Field Integrals: Int Bx dz = -6.6138e-005 Tm Int Int Bx dz dz = -6.8037e-005 Tm^2 Int By dz = 7.7059e-005 Tm Int Int By dz dz = 7.9839e-005 Tm^2 Trajectory Exit Information: X at exit = 1.7580e-006 m X slope at exit = 1.6968e-006 Y at exit = 1.4981e-006 m Y slope at exit = 1.4563e-006 Calculated Undulator Parameters: Keff = 3.489521 Beff = 1.245777 T Lambda_rad = 1.497680e-010 m Calculated K Value At 20 C: (Assumes Keff changes by -.05% per degree C) Measured Average Undulator Temperature = 20.027500 C Measured Keff = 3.489521 Calculated Keff at 20 C = 3.489569 Relative Change (Keff_20C - Keff) / Keff = 0.000014 Phase Fluctuations: Slippage vs Z At Peaks Fitted Slope = 4.99246e-009 Undulator Period = 0.029999 m Radiation Wavelength = 1.49768e-010 m Phase Error (From Slippage vs Z Fit Residuals): Ave = -0.000000 deg, RMS = 4.350476 deg Phase Relative To Nominal Radiation Wave: Nominal Radiation Wavelength = 1.49770e-010 m Cell Length = 3.656000 m Number Of End Poles = 4 Entrance: Phase Error Of First 10 Poles After The End Poles Ave = 2.092267 deg, RMS = 3.023385 deg Center: Phase Error Of All Poles In Undulator Center: Ave = -1.737819 deg, RMS = 4.417934 deg Exit: Phase Error To Cell Boundary Of Last 10 Poles Before The End Poles Ave = 0.833600 deg, RMS = 4.054720 deg Cell: Phase Change Of Cell = 40679.224 deg Nominal Phase Change Of Cell = 40680.000 deg Phase Error Of Cell = -0.776 deg Calculated Phase Change In The Cell At 20 C: (Relative to the nominal radiation wave) (Assumes Keff changes by -.05% per degree C) Measured Average Undulator Temperature = 20.027500 C Measured Phase Change Of Cell = 40679.224 deg Calculated Phase Change Of Cell At 20 C = 40680.185 deg Phase Change Due To Temperature (Phase_20C - Phase) = 0.961 deg