SLAC Magnetic Measurements Date: 07-18-2008 Time: 16:18:03 Planar Insertion Device Analysis -------------------------------- Data File Header: SLAC Magnetic Measurements Date: 07-18-2008 Time: 16:04:50 Project: LCLS Device Type: Undulator Data Type: Serial Number: L143-112000-38 DATASET Number: 1 Tuning Stage: Rough Tuning Run Number: 75 Measurement Type: Z Scans Operator: aw Comment: f.p. 0.37200, x=0.026496 y=0.00028668. Add phase shim 0.1 mm at 59. Measurement Device x: Measurement Device y: SENIS_24-06 Data File: s:\magdata\LCLS\Undulator\L143-112000-38\DATASET0001\Rough Tuning\Z Scans\Run 075\bscanz.dat Temperature (C) L143-112000-38:--> top_start 20.09 --> top_mid 20.10 --> top_end 19.98 --> bot 20.08 --> granite 20.02 --> Air 19.95 Axes position (m) X:0.026496 Y:0.000286 Initial Hall Probe Zero Measurements: Vx_0i = -0.000489 V Vy_0i = -0.000264 V Final Hall Probe Zero Measurements: Vx_0f = -0.000440 V Vy_0f = -0.000314 V Offset Correction Voff = offset+index*increment index = 0,1...19850 Vx:offset = -0.000489 V, increment = 2.493E-09 V Vy:offset = -0.000264 V, increment = -2.512E-09 V Hall Probe Calibration File: Y: C:\CVI\current_calib\SENIS_24-06\SENIS_24-06_y.ini X: c:\cvi\current_calib\HALLx_calib_poly_fit_file.dat Reference Magnet Measurements: Bx_ref = 0.0000xx (T) By_ref = 0.0000xx (T) Magnetic Field Measurements vs Z Analysis Parameters: Input file directory = S:\MagData\LCLS\Undulator\L143-112000-38\DATASET0001\Rough Tuning\Z Scans\Run 075\ Input file name = x+00000_y+000_bscanz.dat Input file type = ZVXYBXYH Correction required = 1 Correction, Bx multiplicative factor = 1.000000 Correction, By multiplicative factor = 1.000000 Correction, Bx additive constant = 0.000015 T Correction, By additive constant = 0.000000 T Correction Bxy additive file = S:\Magdata\Earth Field Correction\earth_field_corr.dat Correction Bxy additive file type = CORR_ZBXY Electron gamma = 26644.120000 Electron energy = 13.615120 Gev Nominal undulator period = 0.030000 m Nominal K value = 3.489476 Nominal radiation wavelength = 1.497703e-010 m Number of undulator poles = 226 Number of end poles (used in analysis) = 4 Cell length = 3.656000 m Nominal phase change through cell = 709.999940 rad Nominal phase of pole after end poles = 14.137167 rad Save as final result = 0 Result file directory = c:\magdata\slac_und_2\ Result file name = zscan_xn0060yp0002.dat Figures close on exit = 0 Figures visible = 1 !!!!!!!!!!!!!!!!!!!!!!!!!!!!!! The Measured Fields Were Corrected: Bx_corr = CORR_BX_MULT * Bx + CORR_BX_ADD + CORR_BX_ADD_FILE By_corr = CORR_BY_MULT * By + CORR_BY_ADD + CORR_BY_ADD_FILE Parameters: CORR_BX_MULT = 1.000000 CORR_BY_MULT = 1.000000 CORR_BX_ADD = 0.000015 T CORR_BY_ADD = 0.000000 T CORR_BX_ADD_FILE = S:\Magdata\Earth Field Correction\earth_field_corr.dat CORR_BY_ADD_FILE = S:\Magdata\Earth Field Correction\earth_field_corr.dat !!!!!!!!!!!!!!!!!!!!!!!!!!!!!! Peak And Zero Field Summary: Number of Poles = 226 Number of End Poles (excluded in statistics) = 4 Peak Fields: Ave = 1.272172 T, RMS = 0.005234 T Peak Field Spacing: Ave = 0.014999 m, RMS = 0.000021 m Zero Field Spacing: Ave = 0.015000 m, RMS = 0.000045 m Average Undulator Period = 0.029999 m Hall Probe Overall Field Integrals: Int Bx dz = -2.9631e-005 Tm Int Int Bx dz dz = 2.1170e-005 Tm^2 Int By dz = 3.2299e-005 Tm Int Int By dz dz = -2.9389e-005 Tm^2 Trajectory Exit Information: X at exit = -6.4712e-007 m X slope at exit = 7.1120e-007 Y at exit = -4.6615e-007 m Y slope at exit = 6.5245e-007 Calculated Undulator Parameters: Keff = 3.489465 Beff = 1.245758 T Lambda_rad = 1.497638e-010 m Calculated K Value At 20 C: (Assumes Keff changes by -.05% per degree C) Measured Average Undulator Temperature = 20.062500 C Measured Keff = 3.489465 Calculated Keff at 20 C = 3.489574 Relative Change (Keff_20C - Keff) / Keff = 0.000031 Phase Fluctuations: Slippage vs Z At Peaks Fitted Slope = 4.99232e-009 Undulator Period = 0.029999 m Radiation Wavelength = 1.49764e-010 m Phase Error (From Slippage vs Z Fit Residuals): Ave = -0.000000 deg, RMS = 4.270745 deg Phase Relative To Nominal Radiation Wave: Nominal Radiation Wavelength = 1.49770e-010 m Cell Length = 3.656000 m Number Of End Poles = 4 Entrance: Phase Error Of First 10 Poles After The End Poles Ave = 2.063685 deg, RMS = 2.888616 deg Center: Phase Error Of All Poles In Undulator Center: Ave = -0.547543 deg, RMS = 4.408498 deg Exit: Phase Error To Cell Boundary Of Last 10 Poles Before The End Poles Ave = 0.596688 deg, RMS = 4.539355 deg Cell: Phase Change Of Cell = 40679.355 deg Nominal Phase Change Of Cell = 40680.000 deg Phase Error Of Cell = -0.645 deg Calculated Phase Change In The Cell At 20 C: (Relative to the nominal radiation wave) (Assumes Keff changes by -.05% per degree C) Measured Average Undulator Temperature = 20.062500 C Measured Phase Change Of Cell = 40679.355 deg Calculated Phase Change Of Cell At 20 C = 40681.539 deg Phase Change Due To Temperature (Phase_20C - Phase) = 2.184 deg